Maintenance & Operating
Instructions
For
Dixon Bayco
5200-SFI and 5200-SFI-3 Sight
Glass Kit
For Sales and Service Contact
USA:
Dixon Bayco USA
Chestertown, Maryland
Phone: 410-778-2000
Fax: 410-778-4702
Toll Free: 800-355-1991
E-mail: [email protected]
Europe:
Dixon Group Europe Ltd
Preston, England
Phone: +44 (0)1772 323529
Fax: +44 (0)1772 314664
E-mail: [email protected]
Mexico:
Dixva, S. de R.L. de C.V.
Monterrey, N.L
Phone: 01-800-00-DIXON (34966)
Fax: 01-81-8354-8197
E-mail: [email protected]
Canada:
Dixon Group Canada Limited
Innisfil (Barrie), Ontario
Phone: 705-436-1125
Fax: 705-436-6251
Toll Free: 877-963-4966
E-mail: [email protected]
Asia Pacific:
Dixon (Asia Pacific) Pty Ltd Wingfield,
South Australia
Phone: +61 8 8202 6000
Fax: +61 8 8202 6099
E-mail: [email protected] dixonvalve.com
5200-SFI and 5200-SFI-3 Sight Glass Kit
5200-SFI / 5200-SFI-3 Sight Glass Replacement
Disassembly
SAFETY GLASSES MUST BE WORN DURING
DISASSEMBLY AND SERVICE.
1. Remove the retaining ring from the assembly.
2. It is recommended to apply penetrating oil to ease removal of the sight glass.
3. Refer to figure 1. Put assembly on the top of two blocks approximately 2” thick. The end that contained the retaining ring must face down. Press the sight glass with screw driver as shown.
4. After the sight glass and O-rings have been removed, thoroughly clean the O-ring grooves to remove any debris and penetrating oil.
Figure 1 – Sight Glass Removal
2 877.582.3569 5200-SFI and 5200-SFI-3
5200-SFI and 5200-SFI-3 Sight Glass Kit
Assembly
1. Insert the new O-rings in to the grooves.
2. Apply O-ring lubricant on the outside face of the sight glass to reduce friction. Position the new sight glass as shown in figure 2, making sure that the edge with the chamfer will pass the O-rings first then press the sight glass evenly into the bore. If necessary use the old sight glass to push down the new sight glass.
3. Insert retaining ring into the groove in the body.
4. Verify the new seals and sight glass do not leak by capping one end and applying low air pressure (3 to 5 PSI) and checking for air bubbles under water.