Maintenance & Operating

Instructions

For

Dixon Bayco

5200-SFI and 5200-SFI-3 Sight

Glass Kit

For Sales and Service Contact

USA:

Dixon Bayco USA

Chestertown, Maryland

Phone: 410-778-2000

Fax: 410-778-4702

Toll Free: 800-355-1991

E-mail: [email protected]

Europe:

Dixon Group Europe Ltd

Preston, England

Phone: +44 (0)1772 323529

Fax: +44 (0)1772 314664

E-mail: [email protected]

Mexico:

Dixva, S. de R.L. de C.V.

Monterrey, N.L

Phone: 01-800-00-DIXON (34966)

Fax: 01-81-8354-8197

E-mail: [email protected]

Canada:

Dixon Group Canada Limited

Innisfil (Barrie), Ontario

Phone: 705-436-1125

Fax: 705-436-6251

Toll Free: 877-963-4966

E-mail: [email protected]

Asia Pacific:

Dixon (Asia Pacific) Pty Ltd Wingfield,

South Australia

Phone: +61 8 8202 6000

Fax: +61 8 8202 6099

E-mail: [email protected] dixonvalve.com

5200-SFI and 5200-SFI-3 Sight Glass Kit

5200-SFI / 5200-SFI-3 Sight Glass Replacement

Disassembly

SAFETY GLASSES MUST BE WORN DURING

DISASSEMBLY AND SERVICE.

1. Remove the retaining ring from the assembly.

2. It is recommended to apply penetrating oil to ease removal of the sight glass.

3. Refer to figure 1. Put assembly on the top of two blocks approximately 2” thick. The end that contained the retaining ring must face down. Press the sight glass with screw driver as shown.

4. After the sight glass and O-rings have been removed, thoroughly clean the O-ring grooves to remove any debris and penetrating oil.

Figure 1 – Sight Glass Removal

2 877.582.3569 5200-SFI and 5200-SFI-3

5200-SFI and 5200-SFI-3 Sight Glass Kit

Assembly

1. Insert the new O-rings in to the grooves.

2. Apply O-ring lubricant on the outside face of the sight glass to reduce friction. Position the new sight glass as shown in figure 2, making sure that the edge with the chamfer will pass the O-rings first then press the sight glass evenly into the bore. If necessary use the old sight glass to push down the new sight glass.

3. Insert retaining ring into the groove in the body.

4. Verify the new seals and sight glass do not leak by capping one end and applying low air pressure (3 to 5 PSI) and checking for air bubbles under water.

Figure 2 – Sight Glass Assembly

Dixon Bayco Warranty

For complete warranty information, please refer to the latest

Dixon catalog.

5200-SFI and 5200-SFI-3 877.582.3569 3