advertisement
RESET
MICRO
SD
RESET
MICRO
SD
ETHERNET
DO
C 1
DI
C 1
DC12V
+
RESET
MICRO
SD
DO
C 1 C
DI
1
DC12V
+
ETHERNET
DO
C 1 C
DI
1
DC12V
+
ETHERNET
RESET
MICRO
SD DO DC12V
ETHERNET
RESET
MICRO
SD DO
C 1 C
DI
1
DC12V
ETHERNET
DO DC12V
ETHERNET
RESET
SD MICRO
Quick Installation Guide
4) Open the dome cover with the provided L wrench (3mm), install the provided ferrite core to the LAN cable by referring to
About the manuals
Part names and functions
DO
C 1 C
DI
1
DC12V
+
Please check the name and the position of each part by the squared image on the bottom left of this page, and connect
Before operating the unit, please read this manual thoroughly and keep it for future reference.
Please access our website and download necessary IPAdminTool first: http://www.rivatech.de/en/downloads/software
NC3512(63IR)12-2016-A
This manual provides the instructions for the quick installation and the basic configuration of your IP device. For more detailed
DO DI DC12V
C C 1
+ device’s installation guide and the web page user’s manual.
referring to the following image.
ETHERNET
ETHERNET all the necessary cables dropped from the ceiling to the corresponding connectors on the camera.
5) Prepare the screws (M4x30) with the O-rings inserted. Then, place the camera body to match the alignment holes with the corresponding plastic anchors, insert the O-ring inserted screws into the screw holes on the camera body, and tighten them into
RESET
RESET the plastic anchors with a screw driver.
6) Adjust the angle of the camera. Refer to the section,
Adjusting angle of camera for more information.
MICRO
7) Adjust zoom and focus of the camera. Refer to Adjusting zoom and focus for more information.
8) Reattach the dome cover to the camera body by aligning the alignment marks on both the dome cover and the camera body.
MICRO
SD
9) Once the dome cover and the camera body are properly
RESET aligned, tighten the bolts on the dome cover into the camera
ETHERNET body with the provided L wrench for the firm attachment. Then,
DO
C 1 C
DI
1
DC12V
+
CAUTION
To prevent from damage, place the camera on a stable and nonvibrating surface.
Adjusting angle of camera
Reset button
Ethernet connector gimbal bracket
A. To pan, rotate the gimbal bracket clockwise or counter-clockwise.
(The panning range is limited to 358 degrees.)
C
1
C
C
1
1
DI DC12V
+
C 1 C 1 O I DO DI DC 12V
C
DI
1
AUDIO
I
DC12V
+
O
C 1 C 1 - + micro
SD/SDHC card slot
Terminal Connector: Connect the 6 pin terminal block for a sensor, an alarm and a DC12V power cable.
Ethernet Connector: Connect an RJ-45 LAN cable for 10/100 Base-T
Ethernet (PoE supported).
Reset Button: Press the button either for the restart or the factory default of the device. For restart ,
1.
press the button only for 2 seconds while the device is powered on.
2.
Wait for the system to reboot. For factory default , the device is powered on.
2.
1.
press the button for 10 second while
Wait for the system to reboot. mircoSD/SDHC Card Slot: Insert a card up to 32GB.
Class 4 or the above is recommended for HD recording.
Installation
There is only one type of mounting explained in this manual. Refer to the device’s installation guide for more various mounting types. gimbal tilt stopper
B. To tilt, tilt the gimbal by referring to the image on the left.
ETHERNET
WIRE
ETHERNET
WIRE
M4x30 screw
1) Place the installation template included in the package on a desired installation surface.
2) Drill three holes for the plastic anchors based on the template paper, and insert the plastic anchors into the holes. (In case you need to connect the cables through the mounting surface, drill an additional hole to pass the cables based on the size of the cable entry hole.)
3) Attach the provided silicon waterproof band to the bottom of the camera body for the prevention of water permeation. inner liner
C. For the horizontal rotation of the lens, rotate the inner liner clockwise or counter-clockwise.
(The rotating range is limited to 358 degrees.)
NOTE
Tighten the tilt stopper after the tilt angle is confirmed.
CAUTION
The ambient light sensor shall be uncovered for its normal operation.
CAUTION
Refrain from continuous rotation of the camera gimbal to a single direction as it is linked with the internal cables.
Adjusting zoom and focus
The zoom and focus can be managed via the camera’s web page (path:
Setup>Video>Zoom/Focus). Thus, it is necessary to connect the device on a network in advance to the zoom and focus adjustment.
- Adjust zoom/focus by clicking the arrow buttons: The buttons move the lens more extensively than the buttons .
- If you want to set the focus automatically, click One Click Focus .
- If focus point is considered misaligned, reset it to a zero point by clicking Calibrate .
DO DI DC12V
C 1 C 1
ETHERNET
RESET
MICRO
SD
ETHERNET
WIRE
ETHERNET
WIRE
ETHERNET
WIRE
Setting up network environment
The default IP address of the device is 192.168.XXX.XXX. Users can identify the IP address of the device by converting the MAC address’s hexadecimal numbers. The MAC address is at the bottom of the device. Be sure that the device and the PC are on the same network area before the installation.
Generic IP Environment
1) Convert the device’s MAC address to the IP address. Refer to the
Hexadecimal-Decimal Conversion Table at the end of this manual.
SETUP page
To setup the device configuraiton:
1) Click the Setup button on the upper left corner of the web page.
2) Enter the user name and the password when the login page is displayed. Then, click OK .
(The default user name and the password are root and pass .)
To learn how to set up the camera on the web page for the advanced configurations, refer to the webpage user’s manual.
Safe mode
IPAdminTool
IPAdminTool is a management tool to automatically scan all the network products for the devices’ administrative tasks, which include network configurations, firmware update, device reboot, factory default, and device organization.
Your device will get restarted in safe mode if the device does not completely boot certain times. The main causes for safe mode are as follows.
* The power supply is continually unplugged certain times in the middle of system booting.
* The firmware files required for system booting are damaged.
* There are conflicts in the system settings.
You will see the page to indicate that your device is in safe mode and to guide you what to do by steps. Follow the instructions on the webpage according to each step.
NOTE
One of the methods to update firmware is using IPAdminTool.
Please refer to the manual for IPAdmin Tool for the detailed procedure.
NOTE
If your device is still in safe mode after trying to update firmware, please contact your local agency to get further assistance .
To modify the device’s default IP address for a customized network area;
1) Find the device from IPAdminTool’s list, and highlight the device’s name.
2) Right-click the mouse and select IP Address ; and select Single ;
The IP setup window will appear.
Give a new unique IP address by modifying the last two digits.
3) On the New Information table in the Single IP Change window, modify the last two digits of the device’s IP address, and modify the rest parts including subnet mask, gateway, and DNS if necessary by checking the user/ PC network area information.
4) Make sure to input the correct ID and PW of the device (default: root / pass).
5) Click Apply to complete the modification.
Viewing video on web page
Once the device’s IP address has been identified, type the URL in a web browser to access the camera. At the first time access, the installation window may pop up.
1) When the browser asks to install the AxUMF software, click the
Install button to proceed.
2) When the Setup installation pop-up window appears, click the
Install button to preceed with the rest of the installation.
NOTE
The figures during the installation process may differ depending on the system OS and the IE version.
Hexadecimal-Decimal conversion table
Refer to the following table when converting the MAC address of your device to IP address.
33
34
35
36
37
38
39
40
41
42
43
3A 58
3B 59
3C
3D
3E
3F
60
61
62
63
44
45
46
68
69
70
64
65
66
67
47
48
49
71
72
73
51
52
53
54
55
56
57
2C
2D
2E
2F
30
31
32
Hex Dec
25 37
26
27
38
39
28
29
40
41
2A 42
2B 43
44
45
46
47
48
49
50
0E 14
0F 15
10 16
11 17
12 18
13 19
14 20
15 21
16 22
17 23
18 24
19 25
1A 26
1B 27
1C 28
1D 29
1E 30
1F 31
20 32
21 33
22 34
23 35
24 36
3
4
5
6
Hex Dec
0 0
1
2
1
2
3
4
5
6
7
8
7
8
9 9
0A 10
0B 11
0C 12
0D 13
7D 125
7E 126
7F 127
80 128
81 129
82 130
83 131
84 132
85 133
86 134
87 135
88 136
89 137
8A 138
8B 139
8C 140
8D 141
8E 142
8F 143
90 144
91 145
92 146
93 147
Hex Dec
6F 111
70 112
71 113
72 114
73 115
74 116
75 117
76 118
77 119
78 120
79 121
7A 122
7B 123
7C 124
A2 162
A3 163
A4 164
A5 165
A6 166
A7 167
A8 168
A9 169
AA 170
AB 171
AC 172
AD 173
AE 174
AF 175
B0 176
B1 177
B2 178
B3 179
B4 180
B5 181
B6 182
B7 183
B8 184
Hex Dec
94 148
95 149
96 150
97 151
98 152
99 153
9A 154
9B 155
9C 156
9D 157
9E 158
9F 159
A0 160
A1 161
58
59
88
89
5A 90
5B 91
5C 92
5D 93
5E 94
5F
60
61
62
95
96
97
98
63 99
64 100
65 101
66 102
67 103
68 104
69 105
6A 106
6B 107
6C 108
6D 109
6E 110
51
52
53
54
55
56
57
Hex Dec
4A 74
4B 75
4C 76
4D 77
4E 78
4F
50
79
80
81
82
83
84
85
86
87
C7 199
C8 200
C9 201
CA 202
CB 203
CC 204
CD 205
CE 206
CF 207
D0 208
D1 209
D2 210
D3 211
D4 212
D5 213
D6 214
D7 215
D8 216
D9 217
DA 218
DB 219
DC 220
DD 221
Hex Dec
B9 185
BA 186
BB 187
BC 188
BD 189
BE 190
BF 191
C0 192
C1 193
C2 194
C3 195
C4 196
C5 197
C6 198
EC 236
ED 237
EE 238
EF 239
F0 240
F1 241
F2 242
F3 243
F4 244
F5 245
F6 246
F7 247
F8 248
F9 249
FA 250
FB 251
FC 252
FD 253
FE 254
FF 255
Hex Dec
DE 222
DF 223
E0 224
E1 225
E2 226
E3 227
E4 228
E5 229
E6 230
E7 231
E8 232
E9 233
EA 234
EB 235
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement