RIVA RC3502SV-7311 Quick Installation Guide

RIVA RC3502SV-7311 Quick Installation Guide
Quick Start Guide
Before operating the unit, please read this manual thoroughly and
keep this for future reference.
Please access our website and download necessary IPAdminTool first:
http://www.rivatech.de/en/downloads/software
SV3502(73NIR)04-2017-A
About the manual
This manual provides the brief instructions for the installation
and the basic configuration of your IP device. For more
information about the installation and configuration, refer to the
device’s installation guide and the web page user’s manual.
RESET
4) Open the dome cover with the provided L wrench (3mm),
install the provided ferrite core to the LAN cable by referring to
the squared image on the bottom left of this page, and connect
all the necessary cables dropped from the ceiling to the
corresponding connectors on the camera.
5) Prepare the screws (M4x30) with the O-rings inserted. Then,
place the camera body to match the alignment holes with the
corresponding plastic anchors, insert the O-ring inserted screws
into the screw holes on the camera body, and tighten them into
the plastic anchors with a screw driver.
6) Adjust the angle of the camera. Refer to the section,
Adjusting angle of camera for more information.
7) Adjust zoom and focus of the camera. Refer to Adjusting
zoom and focus for more information.
8) Reattach the dome cover to the camera body by aligning the
alignment marks on both the dome cover and the camera body.
9) Once the dome cover and the camera body are properly
aligned, tighten the bolts on the dome cover into the camera
body with the provided L wrench for the firm attachment. Then,
remove the protection film from the dome cover.
ETHERNET
MICRO
SD
DO
DI DC12V
+
C 1 C 1
Please check the name and the position of each part by
referring to the following images.
RESET
ETHERNET
MICRO
SD
DO
DI DC12V
C 1 C 1
RESET
+
Part names and functions
CAUTION
ETHERNET
To prevent from damage, place the camera on a stable and nonvibrating surface.
DO
DI DC12V
C 1 C 1
Adjusting angle of camera
Reset
button
Ethernet
connector
Terminal connector
Reserved DO DI AUDIO DC 12V
X X C 1 C 1 O
+
MICRO
SD
gimbal
bracket
A. To pan, rotate the gimbal bracket
clockwise or counter-clockwise.
micro
SD/SDHC card slot
I - +
(The panning range is limited to 358 degrees.)
Terminal Connector: Connect the provided terminal block for cable
connection of digital input/output, audio input/output, and DC12V
power.
Ethernet Connector: Connect an RJ-45 LAN cable for 10/100 Base-T
Ethernet (PoE supported).
Reset Button: Press the button either for the restart or the factory
1.
default of the device. For restart, press the button only for 2
2.
seconds while the device is powered on. Wait for the system
1.
to reboot. For factory default, press the button for 10 second while
2.
the device is powered on. Wait for the system to reboot.
mircoSD/SDHC Card Slot: Insert a card up to 32GB.
Class 4 or the above is recommended for HD recording.
gimbal
B. To tilt, tilt the gimbal by referring to
the image on the left.
tilt
stopper
inner liner
C. For the horizontal rotation of the
lens, rotate the inner liner clockwise
or counter-clockwise.
Installation
There is only one type of mounting explained in this manual. Refer
to the device’s installation guide for more various mounting types.
(The rotating range is limited to 358 degrees.)
2 turns
NOTE
Tighten the tilt stopper after the tilt angle is confirmed.
ETHERNET
WIRE
CAUTION
Refrain from continuous rotation of the camera gimbal to a single
direction as it is linked with an internal cable.
Adjusting zoom and focus
RESET
M4x30 screw
ETHERNET
The zoom and focus can be managed via the camera’s web page
(path: Setup > Video & Audio > Zoom/Focus). Thus, it is necessary to
connect the device on a network in advance to the zoom and focus
adjustment.
- Adjust zoom/focus by clicking the arrow buttons: The buttons
move the lens more extensively than the buttons
.
- If you want to set the focus automatically, click One Click Focus.
- If the focus point is considered misaligned, reset it to a zero point
by clicking Calibrate.
MICRO
SD
RESET
C 1 C 1
ETHERNET
1) Place the installation template included in the package on a
desired installation surface.
2) Drill three holes for the plastic anchors based on the template
paper, and insert the plastic anchors into the holes. (In case you
need to connect the cables through the mounting surface, drill an
additional hole to pass the cables based on the size of the cable
entry hole.)
3) Attach the provided silicon waterproof band to the bottom of
the camera body for the prevention of water permeation.
DI DC12V
C 1 C 1
+
DO
MICRO
SD
RESET
ETHERNET
MICRO
SD
DO
DI DC12V
C 1 C 1
+
DI DC12V
+
DO
Setting up network environment
SETUP page
The default IP address of the device is 192.168.XXX.XXX. Users can
identify the IP address of the device by converting the MAC
address’s hexadecimal numbers. The MAC address is at the bottom
of the device. Be sure that the device and the PC are on the same
network area before the installation.
Generic IP Environment
1) Convert the device’s MAC address to the IP address. Refer to the
Hexadecimal-Decimal Conversion Table at the end of this manual.
To setup the device configuraiton:
1) Click the Setup button on the upper left corner of the web page.
2) Enter the user name and the password when the login page is
displayed. Then, click OK.
(The default user name and the password are root and pass.)
To learn how to set up the camera on the web page for the
advanced configurations, refer to the webpage user’s manual.
Reboot*
You can reboot the device via the camera’s webpage, too.
1) Go to Setup > Maintenance > Reboot on the camera’s webpage.
2) Click Reboot to reboot the device
*How to reboot on the device is found in the Part names and functions section on the previous page.
IPAdminTool
IPAdminTool is a management tool to automatically scan all the
network products for the devices’ administrative tasks, which
include network configurations, firmware update, device reboot,
factory default, and device configuration.
Factory Default*
You can initialize the current settings to the factory default values
via the camera’s webpage, too.
1) Go to Setup > Maintenance > Reset All Settings on the camera’s webpage.
2) Select the items that you want to preserve from the initialization among
network settings, user account information, and time zone setting.
3) Click Reset All Settings.
*How to do factory default on the device is found in the Part names and functions section on the previous
page.
Safe mode
To modify the device’s default IP address for a customized network
area;
1) Find the device from IPAdminTool’s list, and highlight the device’s
name.
2) Right-click the mouse, select IP Address, and select Single; The IP
setup window will appear.
Your device will get restarted in safe mode if the device does not
completely boot certain times. The main causes for safe mode are
as follows.
* The power supply is continually unplugged certain times in the
middle of system booting.
* The firmware files required for system booting are damaged.
* There are conflicts in the system settings.
You will see the page to indicate that your device is in safe mode
and to guide you what to do by steps. Follow the instructions on the
webpage according to each step.
NOTE
If your device is still in safe mode after trying to update firmware,
please contact your local agency to get further assistance.
Hexadecimal-Decimal conversion table
Give a new unique IP address by
modifying the last two digits.
3) On the New Information table in the Single IP Change window,
modify the last two digits of the device’s IP address, and modify the
rest parts including subnet mask, gateway, and DNS if necessary by
checking the user/ PC network area information.
4) Make sure to input the correct ID and PW of the device (default:
root / pass).
5) Click Apply to complete the modification.
Viewing video on web page
Once the device’s IP address has been identified, type the URL in a
web browser to access the camera. At the first time access, the
installation window may pop up.
1) When the browser asks to install the AxUMF software, click the
Install button to proceed.
2) When the Setup installation pop-up window appears, click the
Install button to preceed with the rest of the installation.
NOTE
The figures during the installation process may differ depending on
the system OS and the IE version.
Refer to the following table when converting the MAC address of
your device to IP address.
Hex
0
1
2
3
4
5
6
7
8
9
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
Dec
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
Hex
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40
41
42
43
44
45
46
47
48
49
Dec
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
Hex
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
6D
6E
Dec
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
Hex
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
87
88
89
8A
8B
8C
8D
8E
8F
90
91
92
93
Dec
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
Hex
94
95
96
97
98
99
9A
9B
9C
9D
9E
9F
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
B0
B1
B2
B3
B4
B5
B6
B7
B8
Dec
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
Hex
B9
BA
BB
BC
BD
BE
BF
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9
CA
CB
CC
CD
CE
CF
D0
D1
D2
D3
D4
D5
D6
D7
D8
D9
DA
DB
DC
DD
Dec
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
Hex
DE
DF
E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
EA
EB
EC
ED
EE
EF
F0
F1
F2
F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
Dec
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement