BEA SPARROW is a unidirectional opening sensor for automatic industrial doors. It uses microwave technology to detect motion with a minimum speed of 5 cm/s. It has adjustable detection field, immunity filter, and output configuration. It can be mounted at a height of 2-6 meters and has a detection range of 10 meters. It is IP64 rated for outdoor use and has a temperature range of -30°C to +60°C.
Advertentie
Advertentie
DESCRIPTION
1
SPARROW
UNIDIRECTIONAL OPENING SENSOR
FOR AUTOMATIC INDUSTRIAL
DOORS*
1. cover
2. main connector
3. radar antenna
4. DIP-switch
5. push buttons
2
3
TECHNICAL SPECIFICATIONS
Technology:
Transmitted frequency:
Transmitted radiated power:
Transmitted power density:
Detection mode:
Min. detection speed:
Supply voltage:
Mains frequency:
Max power consumption:
Output:
Max. contact voltage:
Max. contact current:
Max. switching power:
Mounting height:
Degree of protection:
Temperature range:
Dimensions:
Tilt angles:
Material:
Weight:
Cable lenght:
Conformity: microwave
24.150 GHz
< 20 dBm EIRP
< 5 mW/cm² motion
5 cm/s (measured in the sensor axis)
12V to 24V AC ±10%; 12V to 24V DC +30% / -10%
50 to 60 Hz
< 2 W relay (free of potential change-over contact)
42V AC - 60V DC
1A (resistive)
30W (DC) / 60VA (AC) from 2 m to 6 m
IP64 from -30 °C to + 60 °C
140 mm (L) x 55 mm (H) x 57 mm (W)
0° to 90° vertical; -120° to +120° lateral
ABS
165 g
10 m
RED 2014/53/EU ; 2011/65/EU
Specifications are subject to changes without prior notice.
* Other use of the device is outside the permitted purpose and can not be guaranteed by the manufacturer.
4
5
1
OPENING & CLOSING
Before fixing: After fixing:
2
MOUNTING & WIRING
180°
The sensor can be installed in various positions. But always verify the antenna position.
The sensor can easily replace an EAGLE thanks to the retrofit clip.
1. Remove the clip.
2. Fix it with the
existing screw.
3. Slide the sensor on
the clip.
Avoid proximity to neon lamps or moving objects.
Do not cover the sensor.
1 2
Drill 2 holes using the mounting template.
3
Drill a hole for the cable and pull tinned through towards the sensor
4
... or use one of the cable conduits. Avoid using the one at the top to ensure waterproofness.
5
Pass the cable through the opening.
Fix the sensor firmly to avoid vibrations.
Connect the wires accordingly.
3
DETECTION FIELD
1 2 3
Adjust the lateral antenna angle.
Adjust the vertical antenna angle.
If mounting height > 4.5 m, activate BOOST function by
DIP-switch.
Mounting height: 4 m
Boost function: OFF
Factory values
4
SETTINGS
(by remote control or push buttons)
Mounting height: 6 m
Boost function: ON
Factory values
FIELD SIZE
IMMUNITY FILTER
DETECTION MODE
OUTPUT
CONFIGURATION
RESETTING TO FACTORY VALUES:
XXS XS S < < > > L XL normal high bi
A uni uni
AWAY
P bi = two-way detection uni = one-way detection towards sensor uni AWAY = one-way detection away from sensor
A = active output (NO-contact)
P = passive output (NC-contact)
XXL
OR
FACTORY
VALUES
FIELD SIZE
0
1
2
3 3
2
1
0
1
2
3
0
1
2
3 3
2
1
0
1
2
3
ACCESS CODE
The access code (1 to 4 digits) is recommended to set sensors installed close to each other.
If you forget the access code, cut and restore the power supply .
During 1 minute, you can access the sensor without introducing any access code.
SAVING OR CHANGING AN ACCESS CODE:
DELETING AN ACCESS CODE:
TROUBLESHOOTING
The door will not open.
The LED is OFF.
The sensor power is off.
1 Check the wiring and the power supply.
The door will not close.
The LED is OFF.
The door opens and closes constantly.
It rains and the sensor detects for no apparent reason.
Improper output configuration on the sensor.
Improper wiring
The sensor is disturbed by the door motion or vibrations caused by the door motion.
1
Check the output configuration setting on each sensor connected to the door operator.
Verify wiring
1
2
3
4
5
Make sure the sensor is fixed properly.
Make sure the detection mode is unidirectional.
Increase the tilt angle.
Reduce the field size.
Increase the immunity filter.
The sensor detects the motion of the rain drops.
1
2
3
Make sure the detection mode is unidirectional.
Increase the immunity filter.
Install the ORA (rain accessory).
The sensor detects objects outside its detection field.
The LED flashes quickly after unlocking.
Metallic environment 1
2
Increase the immunity filter.
Decrease the field size.
The sensor needs an access code to unlock.
1
2
Enter an access code.
Cut and restore the power supply to access the sensor. Change or delete the access code.
The sensor does not respond to the remote control.
Batteries in the remote control are weak or installed improperly.
Remote control badly pointed.
1 Check and change the batteries if necessary.
1 Point the remote control towards the sensor.
BEA SA | LIEGE Science Park | ALLÉE DES NOISETIERS 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | [email protected] | WWW.BEA-SENSORS.COM
BEA hereby declares that the SPARROW is in conformity with the basic requirements and the other relevant provisions of the standards 2014/53/EU and 2011/65/EU.
The complete declaration of conformity is available on our website.
This product should be disposed of separately from unsorted municipal waste
Downloaden
Advertentie