BEA EAGLE User's Guide
BEA Eagle is a unidirectional opening sensor designed for high mounting on automatic doors. It uses microwave technology to detect motion and can be used for various applications, including wall mounting above sliding or revolving doors, mounting on door axis (swing doors), and ceiling mounting in front of doors (sliding, revolving, or swing doors). It comes with adjustable lateral and vertical antenna angles, allowing for precise detection. The sensor offers multiple settings for field size, immunity filter, detection mode, output configuration, mounting height, and door control.
Reklam
Reklam
User’s Guide for product version 0600 and higher
See product label for serial number
DESCRIPTION
1
EAGLE ONE HM
UNIDIRECTIONAL OPENING SENSOR
FOR HIGH MOUNTING ON AUTOMATIC DOORS*
3
2
1. main connector
2. antenna
3. push buttons
4. cover
4
TECHNICAL SPECIFICATIONS
Technology:
Transmitter frequency:
Transmitter radiated power:
Transmitter power density:
Detection mode:
Min. detection speed:
Supply voltage:
Mains frequency:
Max power consumption:
Output:
Max. contact voltage:
Max. contact current:
Max. switching power:
Mounting height:
Degree of protection:
Temperature range:
Dimensions:
Tilt angles:
Material:
Weight:
Cable lenght:
Conformity: microwave and microprocessor
24.150 GHz
< 20 dBm EIRP
< 5 mW/cm² motion
5 cm/s
12V to 24V AC ±10%; 12V to 24V DC +30% / -10%
50 to 60 Hz
< 2 W relay (free of potential change-over contact)
42V AC/DC
1A (resistive)
30W (DC) / 60VA (AC) from 4 m to 5 m
IP54 from -20 °C to + 55 °C
120 mm (L) x 80 mm (H) x 50 mm (W)
0° to 90° vertical; -30° to +30° lateral
ABS
215 g
2.5 m
RED 2014/53/EU, RoHS 2 2011/65/EU
Specifications are subject to changes without prior notice.
Measured in specific conditions.
* Other use of the device outside of the permitted purpose can not be guaranteed by the manufacturer.
1
OPENING THE SENSOR
Before fixing
2
MOUNTING & WIRING
After fixing
Do not touch electronical parts.
Avoid vibrations.
Do not cover the sensor.
Avoid proximity to neon lamps or moving objects.
Wall mounting above sliding or revolving door
Mounting on door axis (swing doors) Ceiling mounting in front of door
(sliding, revolving or swing doors)
1 2 3
Apply the mounting template.
Drill 1 hole for the cable and pull it through.
Drill 2 holes for the screws.
EAGLE ONE HM
Connect the wires accordingly:
1 - BROWN - POWER SUPPLY
2 - GREEN - POWER SUPPLY
3 - WHITE - COM
4 - YELLOW - NO
5 - YELLOW - NC or
Position the cable as indicated.
Fix the sensor firmly.
3
MECHANICAL ADJUSTMENTS
1
Adjust the lateral antenna angle.
2
Adjust the vertical antenna angle.
4
SETTINGS
(by remote control or push buttons)
FIELD SIZE
IMMUNITY FILTER
DETECTION MODE
OUTPUT
CONFIGURATION
HOLD-OPEN TIME
MOUNTING
HEIGHT
DOOR CONTROL
XXS
0.5 s
XS S > > > > L XL XXL low normal high bi uni uni
PRM
A P
1 s 2 s 3 s
> > > > > highest uni
AWAY
PRM &
AWAY bi = two-way detection; uni = one-way detection towards sensor uni PRM = one-way detection also of people with reduced mobility uni AWAY = one-way detection away from sensor
A = active output (NO-contact)
P = passive output (NC-contact)
4 s 5 s 6 s 7 s 8 s 9 s
4 m > 4 m auto open closed open = the sensor detects constantly. The LED is ON.
closed = the sensor is in standby and does not detect. The LED is OFF.
FACTORY VALUES
RESETTING TO FACTORY VALUES: OR > 2 seconds
+
FIELD SIZE
... S,
XS
,
XXS ...
L
,
XL
,
XXL
EAGLE ONE HM
ACCESS CODE
The access code (1 to 4 digits) is recommended to set sensors installed close to each other.
SAVING AN ACCESS CODE:
DELETING AN ACCESS CODE:
Once you have saved an access code, you always need to enter this code to unlock the sensor.
If you forget the access code, cut and restore the power supply . During 1 minute, you can access the sensor without introducing any access code.
TROUBLESHOOTING
The door remains closed.
The LED is OFF.
The sensor power is off.
1 Check the wiring and the power supply.
The door does not react as expected.
The door control setting (F2) is set to value 3 (closed).
1 Change the door control setting (F2) to value 1
(automatic).
Improper output configuration on the sensor.
1 Change the output configuration setting on each sensor connected to the door operator.
The door opens and closes constantly.
The door opens for no apparent reason.
The sensor is disturbed by the door motion or vibrations caused by the door motion.
1
2
3
4
5
Make sure the sensor is fixed properly.
Make sure the detection mode is unidirectional.
Increase the antenna angle.
Increase the immunity filter.
Reduce the field size.
It rains and the sensor detects the motion of the rain drops.
1
2
3
Make sure the detection mode is unidirectional.
Increase the immunity filter.
Install the ORA (rain accessory).
In highly reflective environments, the sensor detects objects outside of its detection field.
1
2
3
Change the antenna angle.
Decrease the field size.
Increase the immunity filter.
In airlock vestibules, the sensor detects the movement of the opposite door.
1
2
3
Change the antenna angle.
Change the antenna.
Increase the immunity filter.
The LED flashes quickly after unlocking.
The sensor does not respond to the remote control.
The sensor needs an access code to unlock.
1
2
Enter the right access code.
If you forgot the code, cut and restore the power supply to access the sensor without access code.
Change or delete the access code.
1 Check and change the batteries if necessary.
Batteries in the remote control are weak or installed improperly.
Remote control badly pointed.
1 Point the remote control towards the sensor.
BEA SA | LIEGE Science Park | ALLÉE DES NOISETIERS 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | [email protected] | WWW.BEA-SENSORS.COM
BEA hereby declares that the EAGLE ONE HM is in conformity with the basic requirements and the other relevant provisions of the directives RED 2014/53/EU and RoHS 2 2011/65/EU.
The complete declaration of conformity is available on our website.
Only for EC countries: According to the European Guideline 2012/19/EU for Waste Electrical and Electronic Equipment (WEEE)
İndir
Reklam