- Industrial & lab equipment
- Electrical equipment & supplies
- Power conditioning
- Electrical relays
- FAAC
- XM100
- User manual
FAAC XM100 User Manual
Add to My manuals2 Pages
FAAC XM100 is a universal motion sensor for automatic doors, equipped with microwave and microprocessor technology. It features adjustable sensitivity, angle adjustments for customized detection areas, and a wide detection range from 1.8m to 3m. The sensor operates on 12V to 24V DC power, consuming less than 2W. It provides a reliable detection of motion with a minimum speed of 5cm/s and has a robust design with an IP54 protection rating.
advertisement
![FAAC XM100 User Manual | Manualzz FAAC XM100 User Manual | Manualzz](http://s2.manualzz.com/store/data/062429890_1-e80dc5bbedff8483a44bee93d9ea6dd1-360x466.png)
XM100
USER’S GUIDE
UNIVERSAL MOTION SENSOR FOR AUTOMATIC DOORS
1 General
SENSITIVITY
ADJUSTMENT
Vertical angle: 30°
Mounting height: 2.2m
1
Width of the sensing field: choice of antenna
LED
- LED flashes for a few seconds after power-on.
- LED lights up when the sensor detects motion.
WIRING
GREEN Power supply +12V-24V
BROWN Ground 0V
WHITE Output contact 1 NO
YELLOW Output contact 2 COM
2
Position of detection field: adjust the lateral angle of the planar antenna
3
Depth of detection field: adjust the vertical angle of the planar antenna
1/2
3 Installation
Avoid vibrations!!!
Do not cover the sensor! Avoid moving objects in proximity of the sensor!
Avoid HF lamps and fluorescent lighting in proximity of the sensor!
Do not remove the protection which avoids contact with the electronical parts!
4 Troubleshooting
SYMPTOMS
The door will not open and no red LED lights up.
POSSIBLE CAUSES
The sensor power is off.
CORRECTIVE ACTION
Check the wiring and the power supply.
The door opens and closes constantly. 1. The sensor "sees" the door moving. Increase the tilt angle and/or reduce the sensitivity.
The door will not close.
Red LED OFF
2. Closing the door creates vibrations picked up by the sensor.
1. On-Off switch at door control is in wrong position or faulty.
2. Improper output configuration
Ensure that the sensor is correctly fixed.
Make sure that On-Off switch for door is in the ON or
AUTOMATIC position.
Check the output configuration setting on each sensor connected to the door operator.
5 Technical
Technology
Transmitter frequency
Transmitter radiated power
Transmitter power density
Mounting height
Tilt angles
Detection area (mounting height = 2.2 m)
Detection mode
Minimum speed
Supply voltage
Power consumption
Output (electronic relay)
Max. current
Max. voltage
Temperature range
Norm Conformity
Degree of protection
Material
Color of head housing
Dimensions
Weight
Length of cable
: microwave and microprocessor
: 24.175 GHz
: <20 dBm EIRP
: < 5 mW/cm²
: from 1.8 m to 3 m
: 0° to 90° vertical and -30° to + 30° lateral
: 4m (W) x 2m (D)
: motion
: 5 cm/s (measured in the sensor axis)
: 12V to 24V DC +30% / -10%
: < 2W (VA)
: 250 mA
: 50 VDC/VAC
: -20°C to +55°C
: R&TTE 1999/5/EC; EMC 2004/108/EC
: IP54
: ABS & Polycarbonate
: black smoked, aluminum
: 80 mm (W) x 60 mm (H) x 55 mm (D)
: 140g
: 2.5m
Specifications are subject to changes without prior notice
The declaration of conformity is available on our website: www.faac.it
FAAC S.p.A . - Via Benini, 1 40069 Zola Predosa - Italia - tel. +39 051 61724 - fax. +39 051 758518 - www.faacgroup.com