AMS AS621x Environmental Sensor Datasheet
Werbung
Werbung
Datasheet
DS000677
AS621x
Digital Temperature Sensor
v2-00
• 2020-Feb-24
Document Feedback
AS621x
Content Guide
Content Guide
General Description ....................... 3
Key Benefits & Features .............................. 3
Applications .................................................. 4
Block Diagram .............................................. 4
Ordering Information ..................... 5
Pin Assignment ............................. 6
Pin Diagram .................................................. 6
Pin Description ............................................. 6
Absolute Maximum Ratings .......... 8
Operating Conditions .................... 9
Analog System Parameters ......................... 9
Digital System Parameters ......................... 10
Register Description .................... 11
Register Overview ...................................... 11
Detailed Register Description .................... 12
Serial Interface ........................................... 22
Application Information .............. 31
External Components ................................ 32
Package Drawings & Markings ... 33
Revision Information ................... 35
Legal Information ........................ 36
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 2
Document Feedback
1 General Description
AS621x
General Description
The AS621x IC family is a high accuracy temperature sensor system that communicates via a 2-wire digital bus with other devices. It consists of a Si bandgap temperature sensor, an ADC and a digital signal processor.
The family consists of 3 different variants (AS6212, AS6214 and AS6218). The difference between these variants is the temperature accuracy:
Figure 1:
AS621x Variants
Variant
AS6212
AS6214
AS6218
Temperature Accuracy Remark
±0.2°C
±0.4°C
±0.8°C between -10°C to 65°C between 0°C to 65°C between 0°C to 65°C
The high temperature accuracy (shown in Figure 1) and an ultra-low power consumption (low
operation and quiescent current) makes the AS621x ideally suited for mobile/battery powered applications.
The AS621x is an easy to integrate and use solution, featuring a factory-calibrated sensor, integrated linearization and the possibility to use 8 different I²C addresses, enabling to use eight AS621x devices on one bus.
Additionally the AS621x temperature sensor system features an alert functionality, which triggers e.g. an interrupt to protect devices from excessive temperatures.
1.1 Key Benefits & Features
The benefits and features of AS621x are listed below:
Figure 2:
Added Value of Using AS621x
Benefits
High Measurement Accuracy
Features
± 0.2 °C ( -10°C to 65 °C, for AS6212)
± 0.3 °C (from -40°C to -10°C and from 65°C to
85°C, for AS6212)
± 0.5 °C (for remaining temperature span, for
AS6212)
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 3
Benefits
Low Power Consumption
Supply Voltage Range
Small PCB Footprint
Document Feedback
AS621x
General Description
Features
6 µA @ Operation (typical, @ 4 Hz)
0.1 µA @ Standby (typical)
1.71
– 3.6 V (0 °C to 125 °C)
1.5 mm x 1 mm (WLCSP)
1.2 Applications
●
Electronic Equipment
●
●
●
Tablets
Convertibles
Laptop
●
Personal Computers
●
Wearables
●
HVAC
1.3 Block Diagram
The functional blocks of this device are shown below:
Figure 3 :
Functional Blocks of AS621x
bipolar transistor. The analog signal of the sensing element is converted into a digital signal by the A/D converter and the signal is further processed by a digital signal processor and written into the registers. The registers can be accessed via the serial bus interface (I²C bus).
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 4
Document Feedback
2 Ordering Information
Ordering Code
AS6212-AWLT-S
AS6212-AWLT-L
AS6214-AWLT-S
AS6214-AWLT-L
AS6218-AWLT-S
AS6218-AWLT-L
Package
WLCSP
WLCSP
WLCSP
WLCSP
WLCSP
WLCSP
Marking
AS6212
AS6212
AS6214
AS6214
AS6218
AS6218
AS621x
Ordering Information
Delivery Form Delivery Quantity
Tape & Reel
Tape & Reel
Tape & Reel
Tape & Reel
Tape & Reel
Tape & Reel
500 pcs/reel
5000 pcs/reel
500 pcs/reel
5000 pcs/reel
500 pcs/reel
5000 pcs/reel
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 5
Document Feedback
3 Pin Assignment
3.1 Pin Diagram
Figure 4:
Pin Assignment WLCSP
AS621x
Pin Assignment
In Figure 4 the pin assignment of the WLCSP package is shown. The viewing side is from the top. The
A1 pin is also marked with a point on the top side
3.2 Pin Description
Figure 5:
Pin Description of AS621x (WLCSP)
Pin Number Pin Name
A1
A2
A3
B1
B2
VSS
ALERT/ADD1
SCL
VDD
ADD0
Pin Type
S
(1)
DIO_SOD
DI_S
S
DI_S
Description
Ground Pin
Alert output and address select1
Serial Interface Clock
Positive Supply Voltage
Address select 0
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 6
Document Feedback
AS621x
Pin Assignment
Pin Number Pin Name Pin Type
(1)
Description
B3
(1)
SDA DIO_SOD Serial Interface Data
Explanation of abbreviations:
S Supply
DI_S Digital Schmitt Trigger Input
DIO_SOD Digital Schmitt Trigger Input / Open Drain Output
pins
“SDA” and “SCL”.
The pin “ADD0” must not be left unconnected (refer to section 6.3.3 for further details).
The pin “ALERT/ADD1” is used to set the I²C address and has the additional functionality of triggering an interrupt. In case this ALERT functionality is used, a pull up resistor (to VDD) is necessary. If this functionality is not used it must be connected to VSS or SCL, depending on the selected I²C address
(refer to section 6.3.3 for further details). It must not be left unconnected.
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 7
Document Feedback
AS621x
Absolute Maximum Ratings
4 Absolute Maximum Ratings
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only. Functional operation of the device at these or any other conditions beyond those indicated under “Operating Conditions” is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
Figure 6
Absolute Maximum Ratings of AS621x
Symbol Parameter Min Max Unit Comments
Electrical Parameters
V
DD
/ V
SS
VDIO
Supply Voltage to VSS
IO Pin voltage
I_SCR
Input Current (latch up immunity)
Electrostatic Discharge
ESD
HBM
Electrostatic Discharge HBM
Temperature Ranges and Storage Conditions
Operating Ambient Temperature T
A
T
J
T
STRG
T
BODY
Operating Junction Temperature
Storage Temperature Range
R
HNC
Package Body Temperature
Relative Humidity (noncondensing)
-0.3
-0.3
-100
-40
-40
-55
5
±2000
4
4
100
125
125
125
260
85
V
V mA
V
°C
°C
°C
°C
%
Reference to VSS
Reference to VSS
According to JESD78D
MIL_STD_833J-3015.9
IPC/JEDEC J-STD-020
(1)
MSL
(1)
Moisture Sensitivity Level 1 Unlimited floor life time
The reflow peak soldering temperature (body temperature) is specified according to IPC/JEDEC J-STD-020
“Moisture/Reflow Sensitivity Classification for Nonhermetic Solid State Surface Mount Devices.”
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 8
Document Feedback
5 Operating Conditions
AS621x
Operating Conditions
The AS621x is a complete sensor system that has an integrated sensing element, the analog frontend, the A/D converter and the digital signal processing part.
The digital signal processing part consists of the signal processor, the registers and the serial bus interface.
5.1 Analog System Parameters
Figure 7:
Analog System Parameters of AS621x
Parameter
Supply Voltage
Current Consumption
(4 conversions /s)
Symbol
VDD
Temperature Range T
Standby Current
Consumption
IDD
IDD
Min
1.71
2.0
-40
Typ
3.0
3.0
0.1
0.3
6
Resolution
Conversion Time
Conversion Rate
N
TS
NS
22
16
36
0.25
1
4
8
Supply Voltage Rise
Time
Supply Voltage Slew
Rate
TRise_VDD
SR_VDD 50
20
In Figure 7 an overview of the analog system parameters is given.
Max
3.6
3.6
125
0.4
9.0
7
16
51
0.35
1.35
5.5
10.7
Unit
V
°C
µA
µA
Bits ms
Conv/s
CR[1:0]=00
CR[1:0]=01
CR[1:0]=10
CR[1:0]=11 ms mV/ms
Note
T= 0°C to 125°C
T= -40°C to 125°C
T= -40°C to 65°C
T= 65°C to 125°C
T= -40°C to 65°C
Serial bus inactive
T= 65°C to 125°C
Serial bus inactive from 0.1V to 1.6V from 0.1V to 1.6V
The current consumption for less than 4 conversions per second is lower than the values given in
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 9
Document Feedback
Figure 8:
Temperature Accuracy Values of AS621x
AS621x
Operating Conditions
Variant
AS6212
AS6214
AS6218
Symbol Min
T_ERR
T_ERR
T_ERR
-0.3
-0.2
-0.3
-0.5
-1.0
-0.4
-1.0
-1.0
-0.8
-1.0
Typ Max
0.3
0.2
0.3
0.5
1.0
0.4
1.0
1.0
0.8
1.0
Unit
°C
°C
°C
Note
T= -40°C to -10°C
T= -10°C to 65°C
T= 65°C to 85°C
T= 85°C to 125°C
T= -40°C to 0°C
T= 0°C to 65°C
T= 65°C to 125°C
T= -40°C to 0°C
T= 0°C to 65°C
T= 65°C to 125°C
In Figure 8 the different accuracy values of AS621x are shown. These values are representative for a
3
distribution. All accuracy values are valid for the complete supply voltage range given in Figure 7.
5.2 Digital System Parameters
Figure 9:
Digital System Parameters of AS621x
Parameter Symbol Pins Min Max Unit Note
High level input voltage
Low level input voltage
Hysteresis voltage
V_IH
V_IL
V_HYST
SCL, ADD0 0.7 * VDD
SCL, ADD0
V
0.3 * VDD V
SCL,ADD0,
SDA,Alert
200 1200 mV
Input leakage current I_LEAK
Low level output voltage V_OL
High level input voltage
Low level input voltage
V_IH
V_IL
Low level output voltage V_OL
Tristate leakage current I_OZ
SCL;ADD0 -1
Alert
SDA
SDA
SDA
SDA
0.7 * VDD
-10
1
VSS+0.4
VSS+0.4
10
µA
V
V
0.3*VDD V
V
µA
V_IL=0.0V
I_OL=3mA to VSS
In Figure 9 an overview of the digital system parameters is given.
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 10
Document Feedback
6 Register Description
6.1 Register Overview
Figure 10 :
Register Map with Serial Interface
AS621x
Register Description
In Figure 10 the registers that the device contains are shown.
With the use of the index register, it is possible to address the specific register. The index register is
and read only
6.1.1 Index Register
Figure 11:
Index Register
Bit
0
5
6
7
3
4
1
2
Bit Name
Address Bit
Address Bit
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Default
0
0
0
0
0
0
0
0
Access
RW
RW
RO
RO
RO
RO
RO
RO
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 11
Document Feedback
AS621x
Register Description
Figure 12:
Register Map
Address Symbol Register Description
0x0
0x1
0x2
0x3
TVAL
CONFIG
TLOW
THIGH
Temperature Register
Configuration Register
T
LOW
Register
T
HIGH
Register
Contains the temperature value
Configuration settings of the temperature sensor
Low temperature threshold value
High temperature threshold value
This means that in order to access the different registers, the index register must be set accordingly.
With the exception of the TVAL register (which contains the temperature value data), all registers are read/write accessible.
6.2 Detailed Register Description
6.2.1 Configuration Register (Address 0x1)
Figure 13:
CONFIGURATION Register
Addr: 0x1
Bit
8
9
10
11
12
13
6
7
4
5
2
3
0
1
Bit Name
Reserved
Reserved
Reserved
Reserved
Reserved
AL
CR[0]
CR[1]
SM
IM
POL
CF[0]
CF[1]
Reserved
Default
0
0
0
0
0
0
0
1
0
1
0
0
0
0
Access Bit Description
RW
RW
RW
RW
RW
RO
RO
RO
RO
RO
RO
RO
RW
RW
Reserved
Reserved
Reserved
Reserved
Reserved
Alert Bit (AL)
Conversion RATE (CR)
Conversion RATE (CR)
Sleep Mode (SM)
Interrupt Mode (IM)
Polarity (POL)
Consecutive Faults (CF)
Consecutive Faults (CF)
Reserved
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 12
Document Feedback
AS621x
Register Description
Addr: 0x1
Bit
14
15
Bit Name
Reserved
SS
Default
1
0
Access
RO
RW
Bit Description
Reserved
Single Shot
The configuration register is a 16-bit register which defines the operation modes of the device. Any read/write operation processes the MSB byte first.
to read only. The explanation of the other bits are detailed in the following sections.
6.2.2 Alert Bit
The alert bit can be used to easily compare the current temperature reading to the thresholds that can be set in the TLWO and THIGH registers.
If the polarity bit is set to 0, the AL bit is read as 1 until the converted temperature value exceeds the defined value in the high temperature threshold register THIGH for the number of defined consecutive faults (bits CF). Such an event causes the AL bit to toggle to 0 and the value is kept until the converted temperature value falls below the defined value in the low temperature threshold register
TLOW for the number of defined consecutive faults. If this condition is met, the AL bit is reset to 1.
The polarity bit (POL) defines the active state of the alert bit as depicted in the following figure.
The alert bit has the same setting as the alert output as long as the device is configured for the comparator mode.
Figure 14:
State Diagram of the Alert Bit
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 13
6.2.3
Document Feedback
AS621x
Register Description
Conversion Rate Bits
The conversion rate bits define the number of executed temperature conversions per time unit.
Additional readouts of the temperature register between conversions are possible but not recommended because the value is changed only after a conversion is finished.
Values of 125ms, 250ms, 1s and 4s for a conversion can be configured while the default rate is set to
4 conversions per second. The following table summarizes the different configuration settings:
Figure 15:
Conversion Rate Configuration
Conversion Rate Bits
Bit 6
0
1
0
1
Conversion Rate
Figure 16:
Conversion Sequence
6.2.4 Sleep Mode
The sleep mode is activated by setting the bit SM in the configuration register to 1. This shuts the device down immediately and reduces the power consumption to a minimum value.
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 14
6.2.5
Document Feedback
AS621x
Register Description
The serial interface is the only active circuitry in the sleep mode in order to provide access to the digital registers.
Entering the sleep mode will take some time (120 ms maximum) and the first conversion after the
sleep mode has been entered takes longer than the values specified in Figure 7. It is therefore
recommended when entering sleep mode to trigger a single shot conversion at the same time. After
150 ms (max), the device has then entered the sleep mode and subsequent conversion times are as
After resetting the SM bit to 0, the device enters the continuous conversion mode.
Figure 17:
Sleep Mode Configuration
Sleep Mode Bit
0
1
Operation Mode
Continuous Conversion Mode
Sleep Mode
Interrupt Mode
The interrupt mode bit defines whether the device operates in the temperature comparator mode or the interrupt mode. This defines the operation of the ALERT output as described in the polarity section bit.
Figure 18:
Interrupt Mode Configuration
Interrupt Mode Bit Configuration Mode
0
1
Comparator Mode
Interrupt Mode
The comparator mode is characterized that if the temperature value exceeds the THIGH value, the alert output is changed (e.g. from high to low if the polarity bit is set to 0 and vice versa). The alert output stays in that condition until the measured temperature drops below the defined TLOW value.
The interrupt mode is characterized that it changes the alert output as soon as the measured temperature crosses the THIGH or TLOW value threshold.
The alert bit has the same setting as the alert output if the device is set to comparator mode.
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 15
Figure 19:
Alert Output Functionality
Document Feedback
AS621x
Register Description
6.2.6 Polarity Bit
The polarity bit configures the polarity of the ALERT output. If the polarity bit is cleared, the ALERT output is low active while it becomes high active if the polarity bit is set to ‘1’.
Figure 20:
Polarity Bit Configuration
Polarity Bit
0
1
ALERT Output
Active low
Active high
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 16
6.2.7
6.2.8
Document Feedback
AS621x
Register Description
Consecutive Faults
A fault condition persists if the measured temperature either exceeds the configured value in register
THIGH or falls below the defined value in register TLOW. As a result, the ALERT pin indicates the fault condition if a defined number of consecutive temperature readings meets this fault condition. The number of consecutive faults are defined with two bits (12 and 11) and prevent a false alert if environmental temperature noise is present. The register configuration is shown in the following table.
Figure 21:
Consecutive Faults Bit Settings
Consecutive Fault Bits
Bit 13
1
1
0
0
Bit 12
0
1
0
1
Consecutive Faults (N)
3
4
1
2
Single Shot Conversion
The device features a single shot measurement mode if the device is in sleep mode (SM=1). By setting the “Single Shot-bit” to 1, a single temperature conversion is started and the SS-bit can be read as 1 during the active conversion operation. Once the conversion is completed, the device enters the sleep mode again and the SS-bit is set to 0. The single shot conversion allows very low power consumption since a temperature conversion is executed on demand only. This allows a user defined timing of the temperature conversions to be executed and is used if the consecutive operation mode is not required.
The first conversion triggered in this mode has a longer conversion time. In the section 6.2.4 Sleep
entering the sleep mode.
As the device exhibits a very short conversion time, the effective conversion rate can be increased by setting the single shot bit repetitively after a conversion has finished. However, it has to be ensured that the additional power is limited, otherwise self-heating effects have to be considered.
Figure 22:
Single Shot Conversion Bit Settings
Single Shot Bit Conversion
0
1
No conversion ongoing/ conversion finished
Start single shot conversion / conversion ongoing
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 17
6.2.9
Document Feedback
AS621x
Register Description
High and Low Limit Registers
If the comparator mode is configured (IM=0), the ALERT output becomes active if the temperature equals or exceeds the defined value in register THIGH for the configured number of consecutive faults (N). This configuration is defined by the field CF in the configuration register. The ALERT output remains assigned until the converted temperature value equals or falls below the defined value in register TLOW for the same number of consecutive fault cycles.
If the interrupt mode is configured (IM=1), the ALERT output becomes active if the temperature equals or exceeds the defined value in register THIGH for the configured number of consecutive fault cycles.
It remains active until a read operation is executed on any register. The ALERT output is also cleared if the device is set into sleep mode by setting bit SM in the configuration register.
Once the ALERT output is cleared, it is activated again only if the temperature value falls below the configured value in register TLOW. It remains active unless a read operation has taken place.
This sequence is repeated unless the device is set into the comparator mode. This reset command clears the interrupt mode bit and consequently puts the device into the comparator mode.
The sequential behavior is summarized in the following Figure 23.
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 18
Figure 23:
Alert Operation Modes
Document Feedback
AS621x
Register Description
Comparator Mode
ALERT output cleared
T
≤ TLOW for
N consecutive cycles
T
≥ THIGH for
N consecutive cycles
ALERT output active
General Reset
Command
IM=0 IM=1
Read operation or
Set to sleep mode
ALERT output active
Interrupt Mode
ALERT output cleared
T
≥ THIGH for
N consecutive cycles
ALERT output active
T
≤ TLOW for
N consecutive cycles
ALERT output cleared
Read operation or
Set to sleep mode
The following table defines the content of the registers TLOW and THIGH. For data transmission, the
MSB byte is transmitted first, followed by the LSB byte. The data format for representing the threshold temperatures is equal to the temperature register (TVAL). After a power-up, the registers are initialized with the following default values:
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 19
Document Feedback
Figure 24:
Default Values for THIGH and TLOW
AS621x
Register Description
Register
TLOW
THIGH
Temperature
75 °C
80 °C
Binary Value
0010 0101 1000 0000
0010 1000 0000 0000
The following table defines the register bits of the THIGH and TLOW register.
Figure 25:
Register Bit Settings for THIGH/TLOW
Addr: 0x2 / 0x3
Bit
12
13
14
15
8
9
10
11
6
7
4
5
2
3
0
1
TLOW Register
L8
L9
L10
L11
L12
L13
L14
L15
L4
L5
L6
L7
0
0
0
0
THIGH Register
H8
H9
H10
H11
H12
H13
H14
H15
H4
H5
H6
H7
0
0
0
0
Access
RW
RW
RW
RW
RW
RW
RW
RW
Permanently set to 0
Permanently set to 0
Permanently set to 0
Permanently set to 0
RW
RW
RW
RW
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 20
Document Feedback
6.2.10 Temperature Register (Address 0x0)
Figure 26:
Temperature Value Register
AS621x
Register Description
Addr: 0x0
Bit
11
12
13
14
15
7
8
9
10
4
5
6
2
3
0
1
Bit Name
T7
T8
T9
T10
T11
T12
T13
T14
T15
T0
T1
T2
T3
T4
T5
T6
The temperature register contains the digitally converted temperature value and can be read by setting the index pointer to the TVAL register (0x0).
Two consecutive bytes must be read to obtain the complete temperature value. The MSB byte (Bits 15 to 8) is transmitted upon the first read access and the LSB byte (Bits 7 to 0) is transmitted after the second read access.
A temperature value is represented as a two complement value in order to cover also negative values.
After power-up, the temperature value is read as 0°C until the first conversion has been completed.
One LSB corresponds to 0.0078125°C (=1/128 °C).
The binary values can be calculated according to the following formulas:
Positive values: |Value| / LSB
Negative values: Complement (|Value| / LSB ) + 1
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 21
Document Feedback
AS621x
Register Description
Example 75°C:
75°𝐶/0.0078125°𝐶 = 9600 = 𝐵𝑖𝑛𝑎𝑟𝑦 0010 0101 1000 0000 = 𝐻𝑒𝑥 2580
Example -40°C:
|−40°𝐶|/0.0078125 °𝐶 + 1 = 5120 + 1 = 𝐵𝑖𝑛𝑎𝑟𝑦 0001 0100 0000 0000 + 1 = 1110 1100 0000 0000 =
𝐻𝑒𝑥 EC00
Figure 27:
Temperature Conversion Examples
Temperature (°C)
100.0
75.0
50.0
25.0
0.125
0.0078125
0.0
-0.0078125
-0.125
-25.0
-40.0
Digital Output (Binary)
0011 0010 0000 0000
0010 0101 1000 0000
0001 1001 0000 0000
0000 1100 1000 0000
0000 0000 0001 0000
0000 0000 0000 0001
0000 0000 0000 0000
1111 1111 1111 1111
1111 1111 1111 0000
1111 0011 1000 0000
1110 1100 0000 0000
Digital Output (Hex)
3200
2580
1900
0C80
0010
0001
0000
FFFF
FFF0
F380
EC00
6.3 Serial Interface
The device employs a standard I²C-serial bus.
6.3.1 Bus Description
A data transfer must be invoked by a master device (e.g. microcontroller) which defines the access to the slave device. The master device defines and generates the serial clock (SCL) and the start/stop conditions.
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 22
Document Feedback
AS621x
Register Description
In order to address a specific device, a START condition has to be generated by the master device by pulling the data line (SDA) from a logic high level to a logic low level while the serial clock signal (SCL) is kept at high level.
After the start condition, the slave address byte is transmitted which is completed with a ninth bit which indicates a read (bit=’1’) or a write operation (bit=’0’) respectively. All slaves read the data on the rising edge of the clock. An acknowledge signal is generated by the addressed slave during the ninth clock pulse. This acknowledge signal is produced by pulling the pin SDA to a low level by the selected slave.
Subsequently, the byte data transfer is started and finished by an acknowledge bit. A change in the data signal (SDA) while the clock signal (SCL) is high causes a START or STOP condition. Hence, it must be ensured such a condition is prevented during a data transfer phase.
After completing the data transfer, the master generates a STOP condition by pulling the data line
(SDA) from low level to high level while the clock signal (SCL) is kept at high level.
6.3.2 Data Interface
A bus connection is created by connecting the open drain input/output lines SDA and SCL to the two wire bus. The inputs of SDA and SCL feature Schmitt-trigger inputs as well as low pass filters in order to suppress noise on the bus line. This improves the robustness against spikes on the two wire interface.
Both fast transmission mode (1kHz to 400kHz) and high-speed transmission mode (1kHz to 3.4MHz) are employed to cover different bus speed settings.
Any data transfer transmits the MSB first and the LSB as last bit.
6.3.3 Bus Address
A slave address consists of seven bits, followed by a data direction bit (read/write operation). The slave address can be selected from 8 different address settings by connecting the pin ADD0 and
ADD1 to an appropriate signal as summarized in Figure 28.
The ADD0 and the ADD1 pin must not be left unconnected.
The address selection with ADD1 is depending on the usage of the ALERT function (described in
VDD. In case the ALERT functionality is not used, the pin must be connected to either SCL or VSS
(refer to Figure 28 for details).
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 23
6.3.4
Document Feedback
AS621x
Register Description
Figure 28:
I²C Address Select Configuration
ALERT / ADD1
Connection
SCL
SCL
SCL
SCL
VSS
VSS
VSS
VSS
Pull up to VDD
Pull up to VDD
Pull up to VDD
Pull up to VDD
VSS
VDD
SDA
SCL
VSS
VDD
SDA
SCL
VSS
VDD
SDA
SCL
ADD0 Connection
Alert
Functionality
Enabled
No
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Device Address
(bin)
100 0100
100 0101
100 0110
100 0111
100 1000
100 1001
100 1010
100 1011
100 1000
100 1001
100 1010
100 1011
Device Address
(hex)
0x44
0x45
0x46
0x47
0x48
0x49
0x4A
0x4B
0x48
0x49
0x4A
0x4B
Read/Write Operation
In order to access an internal data register, the index register must be written in advance. This register contains the actual register address and selects the appropriate register for an access. A typical transfer consists of the transmission of the slave address with a write operation indication, followed by the transmission of the register address and is finalized with the actual register content data transfer.
This implies that every write operation to the temperature sensor device requires a value for the index register prior to the transmission of the actual register data.
The index register defines the register address for both the write and read operation. Consequently, if a read operation is executed, the register address is taken from the index register which was defined from the last write operation.
If a different register needs to be read, the index register has to be written in advance to define the new register address. This is accomplished by transmitting the slave address with a low R/W bit, followed by the new content of the index register. Subsequently, the master provokes a START condition on the bus and transmits the slave address with a high R/W bit in order to initiate a read operation.
Since the index register always keeps its last value, reads can be executed repetitively on the same register.
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 24
Document Feedback
AS621x
Register Description
Similarly to the byte transfer where the MSB is transmitted first, the transfer of a 16-bit word is executed by a two byte transfer whereas the MSB byte is always transmitted first.
6.3.5 Slave Operation
The device employs a slave functionality only (slave transmitter and slave receiver) and cannot be operated as a bus master. Consequently, the device never actively drives the SCL line.
6.3.6 Slave Receiver Mode
Any transmission is invoked by the master device by transmitting the slave address with a low R/W bit.
Subsequently, the slave device acknowledges the reception of the valid address by pulling the ninth bit to a low level. Following to acknowledge, the master transmits the content of the index register.
This transfer is again acknowledged by the slave device. The next data byte(s) are written to the actual data register which is selected by the index register while each transfer is acknowledged upon a completed transfer by the slave device. A data transfer can be finished if the master transmits a
START or a STOP condition on the bus.
6.3.7 Slave Transmitter
The master transmits the slave address with a high R/W bit. In turn, the slave acknowledges a valid slave address. Subsequently, the slave transmits the MSB byte of the actual selected data register by the index register. After the MSB byte transmission, acknowledge is sent by the master. Afterwards, the LSB byte is transmitted by the slave which is also acknowledged by the master after the completed transmission. The data transfer can be terminated by the master by transmitting a Not-
Acknowledge after the transmitted slave data or by invoking a START or a STOP condition on the bus.
6.3.8 Alert Function
If the device is configured for an interrupt mode operation (IM=1), the ALERT output can be used as an alert signal.
If the polarity bit is set to ‘0’ (POL=’0’), the alert condition bit is set to ‘0’ in case the temperature has exceeded the configured value in register THIGH. Accordingly, the alert condition bit is set to ‘1’ if the temperature has fallen below the configured value in register TLOW.
If the polarity bit is set to ‘1’ (POL=’1’), the alert condition bit is inverted. The following table summarizes the status of the alert condition bit with different alert conditions and polarity configurations.
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 25
Document Feedback
AS621x
Register Description
6.3.9
Figure 29:
Alert Condition Bit
Polarity Bit
1
1
0
0
Alert Condition
T ≥ THIGH
T ≤ TLOW
T ≥ THIGH
T ≤ TLOW
Alert Condition Bit (AC-Bit)
1
0
0
1
High Speed Mode
The bus operation is limited to 400kHz unless a high speed command is issued by the master device as the first byte after a START condition. This switches the bus to a high speed operation which allows data transfer frequencies up to 3.4MHz. Such a command is not acknowledged by the slave but the input filter time constants on the serial interface (SDA and SCL) are adapted to allow the higher transfer rate.
After a high speed command, the slave address is transmitted by the master in order to invoke a data transfer. The bus keeps operating at the higher operating frequency until the master issues a STOP condition on the serial bus. Upon the reception of the STOP condition by the slave, the input filters are switched to their initial time constants which allow lower transfer rates only.
6.3.10 General Call
A general call is issued by the master by transmitting the general call address (000 0000) with a low
R/W bit. When this command is issued on the bus, the device acknowledges this command. The device also acknowledges the second byte but ignores the data. Subsequent bytes sent by the master during the general call are not acknowledged.
6.3.11 Start Byte
When the master transmits address
000 0000 and a high R/W bit (“START byte”) the device acknowledges the address. The device then send the MSB data byte and LSB data byte, where the data corresponds to the content of the register whose address has been last written to. After reset this corresponds to the temperature register.
6.3.12 Timeout Function
The serial interface of the slave device is reset if the clock signal SCL is kept low for typ. 30ms. Such a condition results in a release of the data line by the slave in case it has been pulled to low level. The slave remains inactive after a timeout and waits for a new START command invoked by the bus master. In order to prevent a timeout, the bus transfer rate must be higher than 1kHz.
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 26
Document Feedback
AS621x
Register Description
6.3.13 Bus Conditions
The following conditions occur on the serial bus which is compatible to the I²C-Bus.
Bus Idle
The signals SDA and SCL are not actively driven and pulled to a high level by an external pull-up resistor.
Start Data Transfer
A transition of the SDA input from high to low level while the SCL signal is kept at high level results in a START condition. Such a START condition must precede any data transfer.
Stop Data Transfer
A transition of the SDA input from low to high level while the SCL signal is kept at high level results in a STOP condition. Any data transfer is finished by generating a STOP or START condition.
Data Transfer
The master device defines the number of data bytes between a START and STOP condition and there is no limitation in the amount of data to be transmitted.
If it is desired to read only a single MSB byte without the LSB byte, a termination of the data transfer can be provoked by issuing a START or STOP condition on the bus.
Acknowledge
It is mandatory for each slave device to respond with acknowledge if the device is addressed by the master. Acknowledge is indicated by pulling down the data line (SDA) while the clock signal (SCL) is high in the acknowledge clock phase. In order to avoid an unwanted START or STOP condition on the bus, setup and hold times must be met.
The master can signal an end of data transmission by transmitting a Not-Acknowledge on the last transmitted data byte by keeping the acknowledge bit at high level.
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 27
6.3.14 Timing Characteristics
Figure 30:
Serial Interface Timing Diagram
Document Feedback
AS621x
Register Description
Figure 31:
Bus Timing Specifications
Parameter Symbol Fast Mode
Min
SCL clock frequency
Bus free time between STOP and START condition
Hold time after repeated
START condition
Repeated START condition setup time
Data in hold time
Data out hold time
(1)
Data setup time
SCL clock low period t t t f
SCL
BUF
HDSTA
SUSTA t
HDDAT t
DH t
SUDAT t
LOW
0.001
600
100
100
0
100
100
1300
0.4 0.001
160
100
100
0
100
10
160
SCL clock high period
Clock/Data fall time t
HIGH t
F
600
300
60
Clock/Data rise time t
R
300
Clock/Data rise time for
SCL
≤100 kHz
(1) t
R
1000
The device will hold the SDA line high for 100 ns during the falling edge of the SCL.
Max
High Speed Mode Unit
Min Max
3.4
80
80
MHz ns ns ns ns ns ns ns ns ns ns ns
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 28
Document Feedback
AS621x
Register Description
6.3.15 Timing Diagrams
The following timing diagrams depict the different bus operation modes and data transmission:
Figure 32:
Timing Diagram for Word Write
Frame 1 : Slave Address Byte Frame 2 : Index Register Byte
1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9
SCL
SDA
1 0 0
A3 A2
A1
A0
R / W
Start by master
Values are defined by ALERT/ADD1 pin setting
Values are defined by
ADD 0 pin setting
Acknowledge by slave
0 0 0 0 0 0 IX 1 IX 0
Acknowledge by slave
Frame 3 : MSB Data Byte
1 2 3 4 5 6 7 8 9
Frame 4 : LSB Data Byte
1 2 3 4 5 6 7 8 9
SCL
( Continued )
SDA
( Continued )
D 7 D 6 D 5 D 4 D 3 D 2 D 1 D 0
Acknowledge by slave
D 7 D 6 D 5 D 4 D 3 D 2 D 1 D 0
Acknowledge by slave
Stop by master
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 29
Document Feedback
AS621x
Register Description
Figure 33:
Timing Diagram for Word Read
Frame 1 : Slave Address Byte Frame 2 : Index Register Byte
1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9
SCL
SDA
1 0 0 A3
A2
A1
A0
R / W 0 0 0 0 0 0 IX 1 IX 0
Start by master
Values are defined by ALERT/ADD1 pin setting
Values are defined by
ADD 0 pin setting
Acknowledge by slave
Frame 3 : Slave Address Byte
1 2 3 4 5 6 7 8 9
SCL
( Continued )
Acknowledge by slave
Stop by master
Frame 4 : Register MSB Data Byte
1 2 3 4 5 6 7 8 9
SDA
( Continued )
Start by master
1 0 0
A3 A2
A1
A0
R / W
Acknowledge by slave
D 7 D 6 D 5 D 4 D 3 D 2 D 1 D 0
Acknowledge by master
Frame 5 : Register LSB Data Byte
1 2 3 4 5 6 7 8 9
D 7 D 6 D 5 D 4 D 3 D 2 D 1 D 0
Acknowledge by master
Stop by master
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 30
Document Feedback
7 Application Information
Figure 34:
Application Example
VDD
R
PU
Microcontroller
(Bus Master)
AS621x
Application Information
Pull-up resistors
Address Select 0
VDD
10nF
SDA
ADD0
VDD
Slave
SCL
ADD1/
ALERT
VSS
Address Select 1
In Figure 34 the connections of the AS621x temperature sensors to a microcontroller and the supply
voltage are shown.
The AS621x is connected to a microcontroller via an I²C bus (SDA and SCL only). Additionally the
Alert output can also be used for temperature monitoring (e.g. using the interrupt mode, refer to IM bit
settings), an example is given in Figure 34 where the Alert output is connected to microcontroller.
The I²C address of the AS621x can be selected by connecting the ADD0 and ADD1 to different pins
(refer to Figure 28 for details). These pins must not be left unconnected.
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 31
Document Feedback
7.1 External Components
Figure 35:
Schematic with External Components
AS621x
Application Information
VDD
R
PU
SCL
SDA
Pull-up resistors
Address Select 0
SDA
ADD0
VDD
VDD
10nF
Slave
SCL
ADD1/
ALERT
VSS
Address Select 1
Alert
Figure 36:
Values for External Components
Parameter
Decoupling capacitor
Pull up resistors
Min
10
Typ
10
Unit
nF k
Ω
In Figure 35 and Figure 36 the schematics and the recommended values for external components are
shown.
The decoupling capacitor for the supply should have a value of at least 10 nF.
In order to use the alert functionality, the ALERT/ADD1 pin must be connected via a pull up resistor to
VDD.
For the serial interface, pull up resistors to VDD are mandatory.
The pull up resistors on the serial interface and the interrupt depend on the bus capacitance and on the clock speed.
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 32
Document Feedback
8 Package Drawings & Markings
AS621x
Package Drawings & Markings
Figure 37:
WLCSP Outline Drawing
Ref. Min Nom Max
X
Y ax dx ay dy d
Thickness
(with balls before reflow)
1475 1495
1005 1025
347.5
1515
1045
400
312.5
400
250
600
RoHS
Green
(1)
(2)
(3)
(4)
All dimensions are in micrometers. Angles in degrees.
Dimensioning and tolerance conform to ASME Y14.5M-1994.
This package contains no lead (Pb).
This drawing is subject to change without notice.
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 33
Document Feedback
Figure 38:
WLCSP Package Marking/Code for AS6212
XXXX
AS6212
XXXX Tracecode
Figure 40:
WLCSP Package Marking/Code for AS6218
XXXX
AS6218
Figure 39:
WLCSP Package Marking/Code for AS6214
XXXX
AS6214
XXXX Tracecode
XXXX Tracecode
AS621x
Package Drawings & Markings
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 34
Document Feedback
9 Revision Information
AS621x
Revision Information
Document Status
Product Preview
Product Status Definition
Pre-Development Information in this datasheet is based on product ideas in the planning phase of development. All specifications are design goals without any warranty and are subject to change without notice
Preliminary Datasheet Pre-Production Information in this datasheet is based on products in the design, validation or qualification phase of development. The performance and parameters shown in this document are preliminary without any warranty and are subject to change without notice
Datasheet Production
Datasheet
(discontinued)
Discontinued
Information in this datasheet is based on products in ramp-up to full production or full production which conform to specifications in accordance with the terms of ams AG standard warranty as given in the General Terms of Trade
Information in this datasheet is based on products which conform to specifications in accordance with the terms of ams AG standard warranty as given in the General Terms of Trade, but these products have been superseded and should not be used for new designs
Changes from previous version (v1-00) to current revision v2-00 Page
Figure 7: Updated conversion time
Updated conversion time reference
9
14
Added clarification for time to enter sleep mode 15
●
●
Added reference for longer first conversion in sleep mode 17
Page and figure numbers for the previous version may differ from page and figure numbers in the current revision.
Correction of typographical errors is not explicitly mentioned.
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 35
Document Feedback
10 Legal Information
AS621x
Legal Information
Copyrights & Disclaimer
Copyright ams AG, Tobelbader Strasse 30, 8141 Premstaetten, Austria-Europe. Trademarks Registered. All rights reserved.
The material herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner.
Devices sold by ams AG are covered by the warranty and patent indemnification provisions appearing in its General Terms of
Trade. ams AG makes no warranty, express, statutory, implied, or by description regarding the information set forth herein. ams
AG reserves the right to change specifications and prices at any time and without notice. Therefore, prior to designing this product into a system, it is necessary to check with ams AG for current information. This product is intended for use in commercial applications. Applications requiring extended temperature range, unusual environmental requirements, or high reliability applications, such as military, medical life-support or life-sustaining equipment are specifically not recommended without additional processing by ams AG for each application. This product is provided by ams AG “AS IS” and any express or implied warranties, including, but not limited to the implied warranties of merchantability and fitness for a particular purpose are disclaimed. ams AG shall not be liable to recipient or any third party for any damages, including but not limited to personal injury, property damage, loss of profits, loss of use, interruption of business or indirect, special, incidental or consequential damages, of any kind, in connection with or arising out of the furnishing, performance or use of the technical data herein. No obligation or liability to recipient or any third party shall arise or flow out of ams AG rendering of technical or other services.
RoHS Compliant & ams Green Statement
RoHS Compliant:
The term RoHS compliant means that ams AG products fully comply with current RoHS directives. Our semiconductor products do not contain any chemicals for all 6 substance categories plus additional 4 substance categories (per amendment EU 2015/863), including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, RoHS compliant products are suitable for use in specified lead-free processes.
ams Green (RoHS compliant and no Sb/Br/Cl):
ams Green defines that in addition to RoHS compliance, our products are free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) and do not contain Chlorine (Cl not exceed 0.1% by weight in homogeneous material).
Important Information:
The information provided in this statement represents ams AG knowledge and belief as of the date that it is provided. ams AG bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. ams AG has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. ams AG and ams AG suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
Headquarters
ams AG
Tobelbader Strasse 30
8141 Premstaetten
Austria, Europe
Tel: +43 (0) 3136 500 0
Please visit our website at www.ams.com
Buy our products or get free samples online at www.ams.com/Products
Technical Support is available at www.ams.com/Technical-Support
Provide feedback about this document at www.ams.com/Document-Feedback
For sales offices, distributors and representatives go to www.ams.com/Contact
For further information and requests, e-mail us at [email protected]
Datasheet
• PUBLIC
DS000677
• v2-00 • 2020-Feb-24
36
│ 36