DRX INSTALLATION MANUAL
WASSP DRX INSTALLATION MANUAL
V 5.0
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 1 of 92
DRX INSTALLATION MANUAL
WASSP DRX INSTALLATION MANUAL
This installation manual covers the following:
»
DRX installation, configuration and operation.
»
Sensor configuration and commissioning.
»
Control and Display Application interfacing.
This manual does not cover installation and setup of external sensors. Refer to installation and operation manuals for the specific sensors that are being used.
DRX Interconnect change history can be seen in
“Appendix F - DRX Interconnect change history” on page 87.
DOCUMENT REVISION HISTORY
REVISION DATE REASON FOR CHANGE
March 2016 Compilation
June 2016
July 2016
November 2016
June 2017
January 2018
March 2018
April 2018
June 2018
Corrected RS-422 pin-out
Connector and Setup Webpages
Various Notes
Update DRX to new configuration
Updates to Section 4 Operating the DRX and Section 5 Sensor Configuration
Update to AUX connector configuration
Update to DRX Interconnection
Updates to support DRX-46
VERSION
1.0
1.1
2.0
2.1
3.0
4.0
4.1
4.2
5.0
RELATED DOCUMENTS
»
WASSP DRX Installation Manual – For the latest version of this manual go to wassp.com
»
WASSP Transducer Installation Manual – Installation manual for specific transducers supported by DRX.
»
WASSP CDX Operators Manual – User manual for the WASSP CDX application for control, visualisation and data post processing of DRX data.
»
3rd Party Application Manuals – 3rd Party Applications that interface with DRX
»
Sensor Installation and Operation Manuals – Sensors supported by DRX.
»
WASSP DRX ICD – Interface documentation for DRX and associated DRX SDK/API documentation.
»
Sensor Box Installation Manual - Installation Manual for the WASSP Sensor package
Further documentation and updated specifications and DRX installation manual can be found at wassp.com
DRX INSTALLATION MANUAL
GENERAL NOTICES
WASSP Ltd. reserves the right to change the contents of this manual and any system specifications without notice.
Contact WASSP Ltd. regarding copying or reproducing this manual.
SAFETY NOTICES
The installer of the equipment is solely responsible for the correct installation of the equipment. WASSP Ltd. holds no responsibility for any damage associated with incorrect installation.
ELECTRICAL SAFETY
»
Fire, electrical shock, or equipment damage may occur if the transceiver comes into contact with liquid.
»
The DRX is rated for operation at 9-32 V DC or 18-32 V DC model dependent.
»
Make sure that the power is switched OFF at the main supply (e.g. switchboard)
before
beginning the installation. Fire or electrical shock may occur if the power is left ON.
»
Do not open or access equipment covers unless you have had DRX service training and are cognisant with the system’s electrical circuits.
»
Make sure all safety precautions for electrical equipment are taken when operating or servicing the equipment. These are to be carried out in accordance with local or national regulatory body safety regulations.
»
Make sure that the DRX is secure and will not loosen due to the vessels vibration.
SUPPORT INFORMATION
For details on Registration, Support and Resources
Registration, Support and Resources” on page 89.
WARNINGS, CAUTIONS AND NOTES
Warnings, cautions, and notes are indicated by the following icons throughout this manual:
WARNING indicates that if the instruction is not heeded, the action may result in loss of life or serious injury.
CAUTION indicates that if the instruction is not heeded, the action may result in equipment damage or software corruption.
NOTE indicates a TIP or additional information that can be helpful while performing a procedure.
Page 2 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 3 of 92
DRX INSTALLATION MANUAL
CONTENTS
3.5.2. Connectors and Components
3.5.3.1. Cables and Components – Front Plate
3.5.3.2. Connectors and Components – Back Plate
3.6. Display and Control Devices
3.6.2. DRX Client Applications
4.2.2. Normal Operation LED Indications
4.3. System Update & Diagnostics
4.3.1. Diagnostics Information
5.1. Commissioning Step 1: Ship Measurements
5.2. Commissioning Step 2: Sensor Configuration
5.2.1.2. Saving Custom Presets
5.2.1.3. Downloading and Uploading Presets
Page 4 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
Doc: DRX Installation
Version: 5.0 June 2018
DRX INSTALLATION MANUAL
5.2.6.1. Configuring Key Pulse Slave
5.2.6.2. Configuring Key Pulse Master
5.2.6.3. Configuring Key Pulse Blanking
5.2.8.1. Configuring Height Relative to the DRX Geoid File
5.2.8.2. Configuring Height Relative to the Internal GPS Geoid
5.3. Commissioning Step 3: On Water Patch Tests
6 CONTROL AND DISPLAY APPLICATION SUPPORT
6.1. Connecting the WASSP CDX to the DRX
6.2. Connecting Maxsea TimeZero Plot to the DRX
6.3. Connecting HYPACK to the DRX
wassp.com
Page 5 of 92
DRX INSTALLATION MANUAL
APPENDIX
Appendix A.2 Transducer Cable Restrainer
Appendix A.11 Power Connection
APPENDIX B - SUPPORTED SENSORS AND SENTENCES
APPENDIX C - SEA LEVEL HEIGHT USING GPS HEIGHT
Appendix C.1 Sea Level Height using DRX Geoid File
Appendix C.2 Sea Level Height using Internal GPS Geoid
Appendix C.3 Enabling GPS Height for Sea Level Height
APPENDIX D - IMS CONTROL IN CDX
APPENDIX E - DRX INTERCONNECT CHANGE HISTORY
APPENDIX G - PRODUCT REGISTRATION, SUPPORT AND RESOURCES 89
Page 6 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
DRX INSTALLATION MANUAL
FIGURES
Figure 10. Startup Sequence 24
Figure 11. Normal Operation LED Indications 25
Figure 16. Ship Measurements Diagram 33
Figure 17. DRX Setup, Port Setup Table 36
Figure 18. DRX Setup, Port Setup Tab with Sensor Data 36
Figure 19. DRX Setup, Sensor Tab 37
Figure 20. DRX Setup, Data Setup Tab 38
39 Figure 21. DRX Setup, Corrections Tab
Figure 22. DRX Setup, Key Pulse Tab 41
Figure 25. GPS Time Delay Stage 1 49
Figure 26. GPS Time Delay Stage 2 50
Figure 27. GPS Time Delay Stage 3 50
Figure 28. Manual Roll Patch Test 52
Figure 29. Measurement of Swath Width H 52
Figure 30. Pitch Corrections 53
Figure 31. DRX-32 Dimensions 61
Figure 32. DRX-32 Front Plate Dimensions 62
Figure 33. DRX-32 Back Plate Dimensions 63
Figure 35. DRX-46 Front Plate Dimensions 65
Figure 36. DRX-46 Back Plate Dimensions 66
Figure 37. DRX-32 Interconnection Diagram
Figure 38. DRX-46 Interconnection Diagram
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 7 of 92
DRX INSTALLATION MANUAL
1 INTRODUCTION
The WASSP DRX is a ‘Black Box’ smart transceiver that interfaces to devices and sensors to make up the WASSP Multibeam Sounder System.
The system can be configured to operate in various modes, typically using a wide-angle sonar transducer to profile the water column and seafloor in high resolution.
Using appropriate sensors, the DRX can be configured to be suitable for operations such as commercial fishing, sport fishing, survey and mapping, exploration, search and rescue and many more.
Actual data types output to client applications, such as WASSP CDX, will be determined by:
»
Data types enabled in DRX, as determined by the licensing model.
»
Data types the client application supports and queries for.
»
If the client application is using raw, processed or post processed data .
»
Data types that are supported will increase through continual product development and DRX upgrades.
The DRX functionality is defined by the software installed, the data types enabled, the transducer connected, and the physical DRX model. The physical DRX model is supported in 4 configurations:
»
WSP-603-200; DRX-25 wideband model (no longer available).
»
WSP-603-200; DRX-32 wideband model used with S3 and F3 products.
»
WSP-603-205; DRX-32 wideband model with IP67 rating.
»
WSP-603-250: DRX-46 wideband model used with F3X.
The same software package is applicable to all models.
For specification details on each model
see “9 Technical Specifications” on page 69
.
NOTE: DRX Serial numbers below #70 are model DRX-25.
DRX Serial numbers #70 and above are DRX-32.
DRX Serial numbers #10001 and above are DRX-46
DRX INSTALLATION MANUAL
1.1. MAIN FEATURES
The main features of DRX in a multibeam configuration will depend on the model as follows:
»
Variable number of beams - Model and configuration dependent.
»
120° Swath coverage – Transducer dependent.
»
Depth capability is configuration and environment dependent. Typical configurations:
• DRX-25 with WMB160 transducer; 1 to 150m
• DRX-32 with WMB160 transducer; 1 to 200m
• DRX-46 with WMB160 transducer; 1 to 400m
• DRX-46 with WMB80 transducer; 2 to 600m
»
Variable frequencies.
»
Supported by multiple client applications to meet different customer requirements.
»
Direct Ethernet connection to multiple client applications.
»
Continuous real-time 2D and 3D mapping.
»
Easy to operate and quick to install.
»
Web based setup and configuration.
»
Beam stabilisation.
»
Variable beam width.
Page 8 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 9 of 92
DRX INSTALLATION MANUAL
2 SYSTEM OVERVIEW
The WASSP multibeam sounder system requires the following components:
DRX; Transmit, receive, digital signal processing, display processing, License management and data server for client applications.
WASSP TRANSDUCER; See WASSP Transducer Reference Manual.
PC; Control, post processing and viewing of sounder, sonar and mapping needs to be handled by a suitable application, running on PC or tablet.
GPS;
Position and time required for water column and bathymetry geo-referencing.
HEADING SENSOR; Required for correctly orienting the multibeam data.
MOTION SENSOR; Required for stabilising the water column and bathymetry data for vessel roll, pitch and heave.
SOUND VELOCITY PROBE; Required for correcting Sound Velocity in order to improve depth accuracy across the swath.
SOUND VELOCITY PROFILER; For accurate range measurement, sound velocity needs to be known at the transducer and through the water column. The Sound Velocity Profile information can be applied if using 3rd Party applications supporting SVP.
NOTE: As with any multibeam sounder, the quality of the sensors connected will directly affect the performance of the system. Enhancements to system performance include using high precision RTK GPS, accurate sound velocity measurements, sound velocity profiles, and high performance motion sensors.
Your WASSP dealer can advise on sensors to suit your requirements. WASSP recommended sensors are also detailed in this manual,
Supported Sensors and Sentences” on page 82.
The WASSP system can be supplied in various configurations to allow customised or turnkey solutions. These include:
»
DRX and transducer with WASSP CDX and sensor package; Customer supplies PC or tablet and optionally 3rd Party navigation, fishing or survey package.
»
DRX and transducer with WASSP CDX; Customer supplies sensors, PC or tablet and optionally 3rd Party navigation, fishing or survey package.
»
DRX and transducer with WASSP CDX and sensor package and wireless package;
Customer supplies PC or tablet.
For details on WASSP system packages available see wassp.com
NOTE: Sensor package details can be found in the WASSP Sensor Box
Installation Manual.
Some typical system configurations are as follows:
Page 10 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
DRX INSTALLATION MANUAL
2.1. COMPLETE SYSTEM
Web Browser
DRX Setup webpages
USER PC
WASSP CDX
Data Manager or 3rd Party
Application
WASSP
Transducer
DC Power
PPS KP
Required
Optional
Figure 1. Complete System
2.2. RECOMMENDED SYSTEM
Satellite
Compass
GPS / HDG /
Motion
GPS
Heading
Sensor
IMU
Pitch /Roll /
Heave
Sound
Velocity
Probe
USER PC
WASSP CDX
Data Manager
Satellite
Compass
GPS / Heading
IMU
Roll / Pitch /
Heave
WASSP
Transducer
DC Power
Figure 2. Recommended System
See “Appendix B - Supported Sensors and Sentences” on page 82
for supported sensors.
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 11 of 92
DRX INSTALLATION MANUAL
2.3. SURVEY SYSTEM
RTK GPS
USER PC
3rd Party survey SW
–Hypack,
Qinsy, Eiva …
Heading
Sensor
IMU
Pitch /Roll /
Heave
Sound
Velocity
Probe
WASSP
Transducer
DC Power
PPS
Figure 3. Survey System
NOTE: Check “Appendix B - Supported Sensors and Sentences” on page 82
for which sensors and sentences are support for input of position, heading, attitude and sound velocity.
Page 12 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
DRX INSTALLATION MANUAL
3 INSTALLATION PROCEDURES
Basic Installation Flow:
CHECK INSTALLATION PARTS
(Section “3.1. Installation Parts” on page 14)
- Check that all parts for installation have been received.
This should include: cables, connectors, brackets etc.
TRANSDUCER
(Section “3.2. Transducer” on page 14)
- Install the Transducer
- Install the Transducer Cable Gland
LOCATE DRX / GPS / SENSORS
(Section “3.3. Locating the DRX System” on page 14)
- Run cables to DRX location
MOUNT THE DRX
(Section “3.4. Mounting the DRX” on page 15)
CONNECTING THE DRX
(Section “3.5. Connecting the DRX” on page 17)
- Connect Power to DRX
- Connect Transducer to DRX
- Connect Sensors to DRX
CONNECT DISPLAY AND CONTROL DEVICE
(Section “3.6. Display and Control Devices” on page 22)
- DRX Setup and Configuration
- Control, Display and Data
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 13 of 92
DRX INSTALLATION MANUAL
3.1. INSTALLATION PARTS
Standard supply:
»
1 x DRX unit
»
4 x Connector plugs
»
1 x power cable
»
1 x LAN cable
»
1 x USB Flash Drive:
• Find My DRX Application
• WASSP CDX Application
• WASSP Utilities
• License key for Data Manager
»
Depending on kit:
• Transducer installation kit (a package with a transducer cable clamp, a TX connector and installation manual)
• Widescan Sensor package (refer to Sensor Box Installation Manual)
»
WASSP DRX Installation Manual
3.2. TRANSDUCER
The DRX supports multiple transducer types and can be setup to operate in a variety of configurations. Typical setup will be multibeam wideband mode with:
»
WMB160
»
WMB80
Detailed specification and mounting methods for supported transducers is described in the WASSP Transducer Installation Manual.
Transducer selection is described in
“5.2.4. Data Setup Tab” on page 37.
3.3. LOCATING THE DRX SYSTEM
The DRX is a highly sensitive receiver which is capable of discerning signals of less than one microvolt. In order to get the highest performance out of the DRX system keep the transducer, transducer cable and the DRX far away from sources of electrical and acoustic noise. AC/DC inverters and DC/DC converters are particularly noisy and even if not used to power the system, should be kept as far away as possible.
The DRX will need to be located with access to all required sensors. This needs to include transducer cable, GPS, motion sensor and LAN connections. Serial cables from sensors should be run direct to DRX with no splitters or interfaces boxes.
When selecting a mounting location, keep the following points in mind to maintain optimal performance:
»
Maintain ambient temperature in the vicinity of the DRX within operating specifications. Operating in temperatures outside of specification will result in reduced operating lifetime or direct failure due to overheating:
• The area needs to be well ventilated in order to avoid local ambient increase from self heating.
• Keep out of direct sunlight. Exposure to sunlight will result in direct solar gain
Page 14 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
DRX INSTALLATION MANUAL
• Keep away from exhaust pipes and vents.
»
Avoid electrical and acoustic noise as this will have a direct impact on system performance:
• Avoid locations close to electrical equipment such as inverter, converters and other power supplies.
• Keep away from electromagnetic field-generating equipment such as motors and generators.
»
To avoid damage to the DRX:
• Locate where Shock and vibration are minimal.
• The area should not be prone water ingress or high moisture content.
CAUTION: Electrical or acoustic noise will directly impact system performance and signal integrity. AC/DC inverters and DC/DC converters will impact system sensitivity and can cause system noise even if not directly connected. If an AC/
DC or DC/DC PSU is required only use low noise, good quality products in order to minimise impact on system performance.
CAUTION: Operating outside the temperature specification will reduce the operating lifetime of the DRX.
For specifications, see “9 Technical
Refer to Knowledge Base for guidelines on the Operating Environment.
Appendix E - Product Registration, Support and Resources” on page 89.
3.4. MOUNTING THE DRX
Installation & Mounting Considerations
The DRX can be installed on a desktop, deck or on a bulkhead.
Using the mounting flanges on the bottom plate, the DRX is mounted vertically on a bulkhead, or horizontally on a hard surface. Important considerations are:
»
A vertical position is ideal for optimal thermal performance (Transducer Connectors front face down).
See ”Figure 4. DRX Bulkhead Mount” on page 16.
»
The second option is horizontal on a hard, flat surface.
»
If mounted in an enclosed space, forced ventilation will be required to maintain an ambient temperature within the stated limits around DRX.
and
See “Figure 5. DRX Horizontal Mount” on page 16.
»
Leave slack in cables for maintenance and servicing ease.
»
For maintenance and checking purposes, leave sufficient space at the sides and rear of the DRX installation location.
»
Fasten the DRX to the mounting location with a minimum of four self tapping screws.
See Section “7 Outline Drawings” on page 61
for DRX dimensions and mounting clearances.
• Mounting screws; Minimum M6 x 40mm x 4.
• When installing the DRX, thread locking fluid or locking washers are recommend to avoid vibration loosening.
• Anti Vibration Mounts are recommended.
»
DRX should be always be mounted on a hard surface capable of supporting the DRX weight.
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 15 of 92
DRX INSTALLATION MANUAL
.
CAUTION: Operating outside the temperature specification will reduce
the operating lifetime of the DRX. For specifications, see
CAUTION: IF DRX is mounted in an enclosed space forced ventilation as described below is required.
Back Plate
300mm clearance
Top
300mm clearance
500mm clearance
300mm clearance
Hard Surface
500mm clearance
Front Plate
Figure 4. DRX Bulkhead Mount Figure 5. DRX Horizontal Mount
Figures 4 and 5 show clearance required for cabling and forced air ventilation if DRX is in an enclosed space.
Before installing the DRX in an enclosed space ensure that the ventilation is sufficient to prevent overheating. Consider the following:
»
Cool air supply needs to be able to adequately dissipate the thermal output of DRX.
»
Ensure the hot exhaust air from the enclosed area does not recirculate into the DRX.
Perforations in the top will assist in removing exhaust air.
»
Install the DRX in a position to allow the air flow to circulate effectively through the outlet.
»
Route all cabling to minimise blockage of airflow.
NOTE: If operating in a high ambient environment forced airflow over the DRX will significantly improve thermal performance. Always make sure that there is adequate ventilation.
Page 16 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
Doc: DRX Installation
Version: 5.0 June 2018
DRX INSTALLATION MANUAL
3.5. CONNECTING THE DRX
This section describes the installation requirements for cables from and to the DRX.
Access to, and connection of all cables should be performed by a qualified installer.
3.5.1. Power Supply
The DRX should use a clean power supply. For best performance use a DC battery supply or as a secondary alternative it is recommended to use a low noise converter.
CAUTION: A noisy power supply will have direct impact on system performance.
3.5.2. Connectors and Components
This section identifies the various connectors exposed on the DRX.
Power On / Off
LED Indicators
Transducer TX
Transducer RX
Figure 6. Front Plate
NOTE: X/TX connector in Transducer RX block is only used for IP67 version of
DRX.
For descriptions,
see “3.5.3.1. Cables and Components – Front Plate” on page 18.
wassp.com
Page 17 of 92
Ethernet Power Grounding
Point
N2K NMEA 0183
Figure 7. Back Plate
CAUTION: All serial cables from sensors on RS-232, RS-422 or NMEA 0183 should be direct with no splitters or interface boxes, unless supplied by
WASSP. Failure to do this will result in compromised mapping performance due to potential timing issues.
For descriptions,
see “3.5.3.2. Connectors and Components – Back Plate” on page 20.
3.5.3. Cables and Components
3.5.3.1. Cables and Components – Front Plate
Power On/Off
The power button controls system on/off through soft control. It requires power to be connected to the unit.
»
Short press the power button to turn the power on. To power down, press and hold the power button for 4 seconds (to prevent bumping starting a power down).
»
Power on/off can also be controlled remotely using the remote control cable on back plate, referenced in the following page.
Page 18 of 92
DRX INSTALLATION MANUAL
FAN
(DRX-46 only)
RS-422-A RS-422-B
FAN
LAN
POWER
RS422-A RS422-B
RS232
N2K 0183 AUX
Serial RS-232
AUX
NOTE: Remote Power Control is described in
Components – Back Plate” on page 20.
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
DRX INSTALLATION MANUAL
Transducer RX
The Transducer RX is connected to the DRX through seven receive cables. The receive cables must be connected in the colour order shown on the connector.
See “Appendix A.1 Transducer RX” on page 70
for connection specification.
7 Receive
Cables
Transmit
Cable
Cable to
Restrainer
Figure 8. RX Cable Connection
CAUTION: The 7 receiver cables MUST be connected in the colour order indicated on the DRX. Failure to do this will result in faulty operation of the
WASSP system.
CAUTION: The cable MUST be fitted with the supplied cable restrainer to prevent stress on the RJ45 Receive connector block.
Transducer Cable Restrainer” on page 71.
NOTE: Actual product may differ from images depending on model.
See “7 Outline Drawings” on page 61.
Transducer TX
The Transducer TX cable applies transmit signal to the transducer.
“Appendix A.3 Transducer TX” on page 72 for connection specification.
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 19 of 92
DRX INSTALLATION MANUAL
3.5.3.2. Connectors and Components – Back Plate
RS-232 IN/OUT
Connector
RS232
RS-232 is a serial connection for sensors/processors that natively output RS-232. For
NMEA 0183 talkers it will depend on the instrument as to whether it will be RS-232 compliant or require a converter. RS-232 supports power out at same voltage as DRX power supply.
See “Appendix B - Supported Sensors and Sentences” on page 82.
RS-232 can be configured using the DRX SETUP WEBPAGES .
Step 2: Sensor Configuration” on page 34.
See “Appendix A.4 RS-232” on page 73
for connection specification.
RS-422 IN/OUT
Connector
RS422-A and RS422-B
RS-422 is a serial connection for sensors natively outputting RS-422 or by using RS-232 to
RS-422 converter. For NMEA 0183 talkers it will depend on the instrument as to whether it will be RS-422 compliant or require a converter.
The RS-422 Connector also supports PPS IN:
»
RS-422-A supports power out at same voltage as DRX power supply
»
RS-422-B allows data forwarding and power out at same voltage as DRX power supply
See “Appendix B - Supported Sensors and Sentences” on page 82.
RS-422 can be configured using the DRX SETUP WEBPAGES .
Step 2: Sensor Configuration” on page 34.
See “Appendix A.5 RS-422-A” on page 74
and
“Appendix A.6 RS-422-B” on page 75
for connection specifications.
NMEA 0183
Connector
0183
NMEA 0183 is a serial connection for sensors natively outputting NMEA 0183 (single talker, multi listener). As well as an NMEA input, this connector also features an NMEA output.
The 0183 Connector also supports PPS IN.
See “Appendix B - Supported Sensors and Sentences” on page 82.
NMEA 0183 can be configured using key DRX SETUP WEBPAGES .
Commissioning Step 2: Sensor Configuration” on page 34.
See “Appendix A.7 NMEA 0183” on page 76
Remote Power
Connector
AUX
A local supplied latching switch can be connected to pins eight (Remote PWR On) and nine (Remote PWR On GND) of connector AUX. When the switched is closed the DRX will power on. When the switch is open (circuit open) then the DRX will power off.
See “Appendix A.8 Remote Power” on page 77 f
or connection specification.
Page 20 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
DRX INSTALLATION MANUAL
KP1/KP2 IN
Connector
AUX
KP IN interface is to allow the DRX to transmit in sync with another sounder/sonar. This feature is useful for helping reduce transmit pulse interference.
KP IN takes the key pulse from an external system (master) and synchronises the DRX
(slave) transmit pulse with that key pulse as a trigger.
See “Appendix A.9 KP1/KP2 In” on page 78
for connection specification.
See “5.2.6. Key Pulse Tab” on page 40
for connection information.
KP1 OUT
Connector
AUX
KP OUT interface is to allow the DRX to transmit in sync with another sounder/sonar.
This mode allows the DRX to be the KP master, and the receiving sounder/sonar to be the slave. This feature is useful for helping reduce transmit pulse interference.
This mode is recommended to optimise the nterference immunity from the connected sounder.
See “Appendix A.10 KP1 Out” on page 79
for connection specification.
See “5.2.6. Key Pulse Tab” on page 40
for connection information.
PPS IN
Connectors
RS422-A, RS422-B and 0183
Pulse-per-second (PPS) input allows connection equipment with a PPS timing output.
PPS input allows the DRX to be accurately synchronised with GPS UTC enabling highly accurate positional timing accuracy, potentially improving mapping data positional accuracy by removing GPS latency issues.
Through the DRX SETUP WEBPAGES the user can choose which PPS input is tied to which input, and view that the signal is being correctly received.
Step 2: Sensor Configuration” on page 34.
See “Appendix A.5 RS-422-A” on page 74
and
“Appendix A.7 NMEA 0183” on page
for connection specification.
Power
The DRX is designed to be run on DC voltage,
see specs in “9 Technical Specifications” on page 69.
See “Appendix A.11 Power Connection” on page 80
Ethernet
Connector
LAN
The Ethernet link is used for all communication between the client application running on PC (or other devices) and the DRX. This link is used for control of the DRX and for the
DRX to supply data for visualisation and post processing to the client device.
The Ethernet connection can be connected either:
• directly using crossover cable or auto crossover (DRX supports auto MDI/MDI-X)
OR
• via a network switch if supporting multiple clients or running the DRX on vessel
LAN (local area network).
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 21 of 92
DRX INSTALLATION MANUAL
The Ethernet connection needs to support at least Gigabit network to enable full functionality.
If there is a DHCP server on the LAN, the DRX will be assigned an appropriate IP address by the DHCP server. If there is no DHCP server, the DRX will fall through to Zeroconfiguration assignment in block 169.254.0.0/16. Any connected device will need to be assigned an appropriate IP address on the same subnet as the DRX, either via DHCP server, Zero-configuration or fixed IP.
See “Appendix A.12 Ethernet” on page 80
NMEA2K
Connector
N2K
See “Appendix B - Supported Sensors and Sentences” on page 82.
See “Appendix A.13 NMEA2K” on page 81
for connection specification.
Power Out
Connector
FAN
Availability dependent on model.
The fan connector powers the optional single or double fan assembly.
See “Appendix A.14 FAN” on page 81
Grounding Point
The grounding point is used to minimise the pickup of noise from interfering sources.
The earth lug on the DRX should be commected to a good earth point on the vessel. Use a short braided cable for optimal noise rejection.
CAUTION: Noise due to poor grounding will have direct impact on DRX performance and signal integrity.
3.6. DISPLAY AND CONTROL DEVICES
The DRX supports two levels of communication over the Ethernet link; web browser based DRX SETUP WEBPAGES and IP based DRX client applications.
In order to initiate communication with the DRX the client needs to know the DRX IP address. This can either be done through the client application discovery mechanism or using the ‘ FIND MY DRX ’ Help utility.
The ‘ FIND MY DRX ’ utility can be run on any PC connected to the DRX over the Ethernet connection. ‘ FIND MY DRX ’ will find any DRX on the network by IP address.
NOTE: The PC only needs a physical Ethernet connection to find DRXs on the network. IP address and subnet is unimportant, however, for connectivity the
DRX Client Application needs to be on the same TCP/IP Subnet.
Page 22 of 92
wassp.com
DRX INSTALLATION MANUAL
Doc: DRX Installation
Version: 5.0 June 2018
Figure 9. Find My DRX App
3.6.1. DRX Setup Webpages
DRX SETUP WEBPAGES are used for upgrade, setup, feature licencing and configuration.
For more details
see
“4 Operating the DRX” on page 24 and “5 Sensor Configuration” on page 32.
The DRX SETUP WEBPAGES are launched by opening any supported web browser and entering the DRX IP address followed by port 2001 e.g. 169.254.54.69:2001
NOTE: Clicking on the appropriate DRX in ‘FIND MY DRX’ will automatically launch the web browser with the appropriate URL.
NOTE: Chrome browser, shipped with DRX, is fully supported. Other browsers may not behave as expected. If webpage does not update use
CTRL F5.
CAUTION: Only one instance of ‘DRX SETUP WEBPAGES’ should be run otherwise a corruption may occur.
3.6.2. DRX Client Applications
Ethernet IP is used for discovery, control and data through supported DRX client applications. Current supported client applications include WASSP CDX, 3rd Party
Navigation, sounder and survey applications and are described in
Application Support” on page 55.
NOTE: For DRX client application connection, the DRX and client application need to be on the same TCP/IP subnet.
If DRX and client applications have incompatible IP addresses, discovery will succeed but connection will fail.
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 23 of 92
DRX INSTALLATION MANUAL
4 OPERATING THE DRX
»
To turn ON the DRX, short press the power key.
»
To turn OFF the DRX, press and hold the power key for more than 4 seconds. All
LEDs will turn off, indicating that power has been turned off.
4.1. POWER
The DRX can be powered on/off using the power button or the remote power switch.
4.2. LED STATUS
The DRX features 4 LEDS next to the power button which give a quick indication of the status of the DRX system.
4.2.1. Startup sequence.
The boot sequence is as below:
Power on
Power Network Ping Error
Booting
Starting
Process
Normal
Operation
Figure 10. Startup Sequence
DRX INSTALLATION MANUAL
4.2.2. Normal Operation LED Indications
Power Network Ping
Figure 11. Normal Operation LED Indications
Power LED:
Off = Power OFF
On Solid = DRXApp is running
Error
Network LED:
Off: No Link (cable not connected)
Solid: Link/Link Established
Blinking: TX or RX traffic
Ping LED:
Off: Not pinging
Blinking: Pinging with frequency relative to ping rate (not actual ping rate).
Error LED:
Off: Normal operation
On: (While booting) system is booting
On: (After booting) Indicates an error state. All LED states should be noted and reported to WASSP Support. See
“Appendix E - Product Registration, Support and Resources” on page 89.
Page 24 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 25 of 92
DRX INSTALLATION MANUAL
4.3. SYSTEM UPDATE & DIAGNOSTICS
The System section of the DRX SETUP WEBPAGES is used for checking DRX versions, upgrading the DRX and restoring the DRX settings.
Launching the DRX SETUP WEBPAGES
“3.6. Display and Control Devices” on page 22.
To check DRX version, open the
DRX SETUP WEBPAGES
and open the
SYSTEM
tab and open the UPGRADE tab. Versions should be recorded by copying and pasting or through screen capture.
CAUTION: Do not power down your DRX during the update procedure, this may result in complete system failure.
CAUTION: System upgrade cannot be performed whilst DRX is pinging as this may result in failure.
NOTE: Note down version numbers before and after upgrading.
To perform a system upgrade:
1. Open the DRX SETUP WEBPAGES , open the SYSTEM tab and select the UPGRADE tab.
2. Select the BROWSE button to navigate to the folder containing the software update package and select the
UPLOAD
button.
3. During the update procedure the DRX system will reboot. Once completed, check the new software version in the System tab.
Figure 12. System Upgrade
Page 26 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
DRX INSTALLATION MANUAL
Upgrade Error Codes
Upgrade may fail for various reasons. An error code and/or text will be displayed in the message box.
1 Transferred Data is not a file.
2 Transferred File is not of valid type.
3 Transferred File contains bad data.
4 Unable to initiate upgrade, stage 1.
5 Failed to install.
6 Unable to initiate upgrade, stage 2.
7 Unable to restart after upgrade.
8 No File transferred.
9 Undefined.
10 Failure. See error log files for detail.
Contact WASSP Support if this error occurs.
TIP: F5 (refresh button) should be pressed if there is any doubt in data consistency between the Webpage and the DRX.
4.3.1. Diagnostics Information
Under SYSTEM tab, UPGRADE option there are diagnostics and information options.
»
DISPLAY DEBUG INFORMATION will display the DRX logs in the display window.
»
CHECK UPGRADE STATUS can be used to confirm with an upgrade has been completed successfully.
»
DOWNLOAD DIAGNOSTICS INFORMATION will download the DRX logs.
NOTE: If there is anything unusual requiring WASSP Support the DRX logs should be supplied for analysis
»
DISPLAY/HIDE SYSTEM INFORMATION shows detailed system information with version and product details.
4.4. SYSTEM RESTORE
System Restore sets all settings to factory default values.
1. Select the SYSTEM tab and select the RESTORE tab.
2. Click the RESTORE DEFAULTS button to restore the unit to default configuration settings. The unit will reboot and you will then need to re-enter all the sensor setup and offset values.
See “5 Sensor Configuration” on page 32.
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 27 of 92
DRX INSTALLATION MANUAL DRX INSTALLATION MANUAL
4.6. SYSTEM FEATURES
DRX optional features can be enabled through license keys.
To enable a feature, the appropriate feature license file needs to be purchased through a WASSP dealer or directly through WASSP Ltd. The license will be supplied as a license file over email, on a USB flash drive or other media. Available features can be seen by selecting SYSTEM tab and selecting FEATURES tab.
Figure 13. Restore Defaults Tab
NOTE:
RESTORE DEFAULTS
will restore entire DRX configuration, not just
Sensor Setup.
4.5. NETWORK CONFIGURATION
Network configuration allows setting the DRX to a fixed IP address.
By default DRX will be assigned an IP through Zero-configuration or by a DHCP server if there is one on the LAN. By setting a fixed IP this will override automatic assignment.
1. Select SYSTEM tab and select NETWORK tab.
2. Use the SET STATIC IP
ADDRESS button to set a fixed IP.
3. Use the REMOVE STATIC
IP ADDRESS BUTTON to revert to automatic IP assignment.
NOTE: The PC/Client Application needs to be in the same subnet as the DRX for connectivity. DRX IP address can always be identified using ‘Find my DRX’ ;
see “Figure 9. Find My DRX App” on page 23.
Page 28 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
Figure 14. System Features
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 29 of 92
DRX INSTALLATION MANUAL
-
-
Licenses can be in one of 3 states:
-
ACTIVE
; License is installed and active.
NOTE: The license may be a permanent or time limited license.
EXPIRED ; License is installed but has expired/timed out.
NO LICENSE ; No License for this feature has been installed.
DRX INSTALLATION MANUAL
NOTE: IMS is not available on all DRXs. Check with WASSP Support with your
DRX Serial Number for more information.
To install the license follow the steps:
1. Select SYSTEM tab and select FEATURES tab.
2. Select the
REFRESH
LICENSE STATUS button to see current active Licenses and associated expiry date.
Figure 15. License Status
Licenced Features include:
Application Interfaces
TIMEZERO ; Allows direct interface between DRX and TZ. TZ controls the DRX and displays data supplied by the DRX, depending on which display functionality is enabled.
SURVEY ; Enables interface between DRX and various survey platforms. DRX supplies the appropriate data for post processing on the survey application.
OLEX ; Allows interfacing to Olex through CDX. Control is required by CDX and display data is passed through to Olex.
Display Functionality
BACKSCATTER ; Seafloor backscatter data is enabled allowing the client application to display backscatter strength on 2D and 3D overlays or to use for post processing.
WATER COLUMN TARGETS ; Targets detections in the water column, such as fish, are enabled. This allows client applications to display discrete targets and their target strengths on the 2D or 3D displays.
SIDESCAN ; Data is processed as sidescan is enabled. This allows port/starboard sidescan imagery on the client application.
Control Functionality
RTK TIDES
; Use of GPS height can be used to compensate for sea level change. This is particularly useful for accounting for tidal height when mapping bathymetry.
Geoids Tab” on page 46 and “Appendix C - Sea Level Height using GPS Height” on page 84.
IMS ; Used for automated optimisation of DRX for improving performance when there is acoustic interference. IMS is enabled or disabled from the client application.
See
“Appendix D - IMS Control in CDX” on page 86.
ADVANCED KEY PULSE ; As part of IMS, AKP (Advanced Key Pulse) functionality can be used to improve management of interfering acoustic equipment. See
Page 30 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
3. Select the BROWSE button to select the appropriate license file.
4. Select UPLOAD button for the selected license file.
5. You will be asked to confirm selection.
6. License file will be uploaded and applied.
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 31 of 92
DRX INSTALLATION MANUAL
5 SENSOR CONFIGURATION
The WASSP system requires position, heading, attitude, heave and time information in order to be fully functional. The overall performance will be directly affected by the quality of the sensors chosen and being configured as described below.
WASSP supplies sensor package kits for recommended install. See the WASSP Sensor Box
Installation Manual for detailed information.
For supported sensors and sentences,
see “Appendix B - Supported Sensors and
NOTE: Currently support sensors and sentences will depend on software version and can be found at wassp.com
5.1. COMMISSIONING STEP 1: SHIP MEASUREMENTS
Take measurements from the GPS antenna, motion sensor and transducer to the vessel’s reference point.
See “Figure 16. Ship Measurements Diagram” on page 33
These measurements must be as accurate as possible.
The accuracy of these measurements have a direct effect on the accuracy of the recorded data.
Enter these values in the spaces below, and in the SENSOR INSTALLATION tab within the
SENSOR tab of the DRX SETUP WEBPAGES .
See “Figure 19. DRX Setup, Sensor Tab” on page 37.
NOTE: The Ships Reference Point is a point close to the ships centre of Pitch and Roll. It pays to make this point easy to measure to for improved accuracy of measurements. A good guideline for a reference point is a point near the water line in the centre of the ship (port to starboard) and half way down the length of the ship.
Transducer (XDCR) Depth (Draft) Displacement:
GPS X Displacement from reference:
GPS Y Displacement from reference:
GPS Z Displacement from reference:
Transducer (XDCR) X Displacement from reference:
Transducer (XDCR) Y Displacement from reference:
Transducer Z Displacement from reference:
Motion Sensor X Displacement from reference:
Motion Sensor Y Displacement from reference:
Motion Sensor Z Displacement from reference: m m m m m m m m m m
🅰
_______
🅱
_______
🅲
_______
🅳
_______
🅴
_______
🅵
_______
🅶
_______
🅷
_______
🅸
_______
🅹
_______
NOTE: Separate sensors can be used for GPS data, heading, roll, pitch and heave as required. Make sure to note down all Sensor offset.
Page 32 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
DRX INSTALLATION MANUAL
Sensor Installation
XDCR X (-)
E
X axis
GPS X (+)
B
GPS
Stern
Negative
IMU
R
XDCR
Reference
IMU X (+)
H
Bow
Positive
Y axis
I
Looking from above
IMU Y (-)
R
XDCR
GPS
Port
Negative
GPS Y (-)
C
Reference
XDCR Y (+)
F
Starboard
Positive
Z axis
Sky
Negative
GPS
GPS Z (-)
D
A
Transducer Draft
R
XDCR
Sea
Positive
R
= Ship’s Reference Point
XDCR Z (+)
G
IMU Z (-)
J
TIP: Transducer Draft is used to adjust for true depth from sea level.
Figure 16. Ship Measurements Diagram
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 33 of 92
2. Select LOAD to apply the chosen preset.
3. Presets will be loaded and set PORT SETUP,
SENSOR, DATA SETUP,
CORRECTIONS . PPS configuration.
DRX INSTALLATION MANUAL
5.2. COMMISSIONING STEP 2: SENSOR CONFIGURATION
The Configuration section of the DRX SETUP WEBPAGES is used for configuring the DRX physical ports and the sensors connected to the DRX.
Launching the DRX SYSTEM WEBPAGE
“3.6. Display and Control Devices” on page 22.
5.2.1. Presets Tab
The
PRESETS
tab allows a selection of preconfigured sensor setup options and the ability to save and retrieve custom or user defined preset options.
5.2.1.1. Applying Presets
1. Select the required preset from the dropdown of
AVAILABLE PRESETS.
NOTE: Sensor Offsets still need to be manually setup.
NOTE: Available Presets will consist of defaults loaded into the DRX and any custom presets applied by the user.
Preset options include:
»
Widescan Sensor Package – V103 With Spatial; Sensor package supplied as optional kit. Reference Sensor Box Installation Manual for details.
»
Widescan Sensor Package – V103 With SMC; Sensor Package available from WASSP
Ltd. Configures as SMC IMU on
RS232
Port and V103 on
RS422
Port with PPS configures.
Page 34 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
DRX INSTALLATION MANUAL
»
SC-30 Standalone; Configuration for customer supply SC-30 used for Position, heading and attitude data. Configure with SC-30 on
0183 port.
These presets may change depending on version and model.
NOTE: Presets will configure PORT SETUP, SENSOR, DATA SETUP,
CORRECTIONS, PPS.
5.2.1.2. Saving Custom Presets
To save current configuration as a Preset:
1. Enter a name for the
Preset under SAVE
CURRENT PRESET.
2. Select STORE PRESET
IN DRX
.
The preset will be stored in the DRX.
5.2.1.3. Downloading and Uploading Presets
Custom configurations can be stored externally to the DRX.
1. Select a custom preset from the Available Presets
2. Select DOWNLOAD and store in your preferred location.
Custom configurations stored externally can be uploaded to the DRX
1. Select
BROWSE
and select the appropriate preset file.
2. Select UPLOAD or
UPLOAD AND USE.
3. The preset will now appear under Available Presets as a custom preset.
NOTE: Only upload presets that were downloaded from the DRX.
5.2.2. Port Setup Tab
The
PORT SETUP
tab is used for configuring the physical DRX ports to receive data from the sensors attached to that port.
NMEA 0183 port can also be used to transmit data and uses the same configuration as receive.
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 35 of 92
DRX INSTALLATION MANUAL DRX INSTALLATION MANUAL
5.2.3. Sensor Tab
The SENSOR tab is used to configure the physical position of each sensor being used and which port that sensor is connected to on the DRX. SENSOR tab is also used for selecting transducer type.
Figure 17. DRX Setup, Port Setup Table
The following options need to be set up for each of the DRX ports being used:
»
Enabled; Marks a port as active or not active.
»
Baud; Sets port’s baud rate to match the sensor baud rate. Bits, Stop Bits, Parity and
Handshake; Configures the port to match the incoming sentences from the sensor.
NOTE: You must COMMIT or these settings will be lost.
NOTE: Port assigned to sensor in the ‘Sensor’ tab.
TIP: F5 (refresh button) should be pressed if there is any doubt in data consistency between the Webpage and the DRX.
The monitor check box can be selected to display the incoming sentences on the specific port. This can be used to identify if the port is configured correctly and the sensors are outputting the correct data.
Figure 18. DRX Setup, Port Setup Tab with Sensor Data
Page 36 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
Figure 19. DRX Setup, Sensor Tab
For each Sensor being used, set the following:
»
SENSOR ; Select the sensor type from the drop down list. Select USER DEFINED if the sensor being used is not listed (any sensors not listed have not been specifically tested with DRX).
»
X, Y, Z OFFSET
; Set the measurement as per section
Ship Measurements” on page 32.
»
PORT ; Select the physical port on the DRX that the sensor is connected to from the drop down list.
Transducer selection allows for currently available
WASSP transducer supported by DRX.
NOTE: You must COMMIT or these settings will be lost.
NOTE: Offsets should be entered in meters to nearest cm (0.01m).
5.2.4. Data Setup Tab
The DATA SETUP tab is used to setup each external data type that is required by DRX to function correctly. Each of the data types; position, heading, roll, pitch, heave and time need to be set.
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 37 of 92
DRX INSTALLATION MANUAL DRX INSTALLATION MANUAL
»
MEAN SEA LEVEL ; Required if RTK Tides feature License is being used for compensating for sea level using GPS height.
See “5.2.8. Geoids Tab” on page 46.
»
COG/SOG ; Allows for COG and SOG display the client application.
NOTE: ‘Current Value’ will display the values being used by the DRX. However these will be raw values and not account for latency settings.
NOTE: Lag is in seconds and Bias is in degrees. Lag should be entered to nearest millisecond and Bias to nearest 0.01 degrees.
NOTE: You must COMMIT or these settings will be lost.
5.2.5. Corrections Tab
The CORRECTIONS tab is used to enable or disable specific attitude corrections being applied, to invert attitude corrections, to correct for depth through adjusting transducer draft and to adjust swath width.
Figure 20. DRX Setup, Data Setup Tab
For each data type setup the following:
»
SENSOR ; The specific sensor that is supplying the data, selected from the drop down. This sensor will have been configured under the
SENSOR
tab.
»
SENTENCE ; Select the appropriate sentence from the drop down. This can be crossreferenced with the data being monitored under the PORT SETUP tab to make sure that it is available to the DRX.
»
LAG ; The sentence lag (also called latency or delay) from the specified sensor should be entered here.
Section “5.3. Commissioning Step 3: On Water Patch Tests” on page 49
gives detail on calculating delay for GPS position. Lag for attitude data should be obtained from the sensor manufacturer specification.
»
BIAS ; The bias (also called offset or correction) of a data type should be entered here.
“5.3. Commissioning Step 3: On Water Patch Tests” on page 49
gives details on calculating bias for each of roll, pitch and heading.
Data Types that are required to be setup include:
»
POSITION and HEADING ; Required for georeferencing the vessel for bathymetry mapping.
»
ROLL PITCH and HEAVE ; Required for compensating for vessel motion
»
TIME ; Required for UTC time synchronisation and specifically for PPS accurate time synchronisation.
Other data types that can be setup include:
»
WATER TEMPERATURE
; Used to calculate sound velocity which is required for multibeam operation
»
SOUND VELOCITY ; Direct input of sound velocity allows for accurate compensation for multibeam operation
Page 38 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
Figure 21. DRX Setup, Corrections Tab
By default, all attitude corrections should be applied for optimal performance. To enable or disable specific attitude corrections:
1. Select the check boxes of the attitude correction that should be applied, under
ENABLED .
2. Press COMMIT button to save any changes.
3. The indicator beside the check box shows the status of the DRX. If the indicator is green the correction is enabled in the DRX. If the indicator is red the correction is disabled in the DRX.
Attitude corrections may need to be inverted if either the sensor is mounted incorrectly
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 39 of 92
DRX INSTALLATION MANUAL or if the sensor supplies inverted roll data, for instance:
1. Select the check boxes of the attitude correction that should be inverted, under
INVERT .
2. Press COMMIT button to save any changes.
3. The indicator beside the check box shows the status of the DRX. If the indicator is green the correction is inverted in the DRX. If the indicator is red the correction is not inverted in the DRX.
TRANSDUCER DRAFT value will correct the depth by taking into account the transducer draft.
See “Figure 16. Ship Measurements
, measurement A.
KEEL DEPTH VALUE will correct the depth by taking in to account the keel depth.
See
“Table 3. NMEA Sentences Output” on page
BATHYMETRY BEAM WIDTH ; The overall swath width for mapping can be adjusted using port and starboard angle from nadir.
Maximum swath width is 60 0 either side of nadir for a 120
0
swath width.
NOTE: ‘Induced Heave’ may depend on whether a motion sensor is configured to account for induced heave.
NOTE: Transducer draft might be adjusted for change in ballast due to fuel, payload etc.
NOTE: You must COMMIT or these settings will be lost.
NOTE: Transducer Invert can be used to correct for a transducer being installed back to front.
5.2.6. Key Pulse Tab
The KEY PULSE tab is use for syncing the DRX transmit to other acoustic equipment that the DRX is physically wired to.
Key pulse configuration will be specific to the vessel and operating environment and is used to optimise operation for all of the equipment by minimising acoustic interference.
Key pulse is configured under the KEY PULSE tab.
Page 40 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
DRX INSTALLATION MANUAL
Figure 22. DRX Setup, Key Pulse Tab
Key Pulse can be configured to either be Disabled, Master, Slave or Auto Modes under
KEY PULSE SETUP .
»
DISABLED
; DRX Tx is not affected by key pulse.
»
MASTER ; DRX will act as a key pulse Tx master.
»
SLAVE ; DRX will act as key pulse slave for Tx.
»
AUTO ; Allows DRX to automatically switch from slave to master with blanking as required.
5.2.6.1. Configuring Key Pulse Slave
In SLAVE mode the DRX will transmit on the key pulse signal from external equipment.
DRX has 2 key pulse inputs available for Slave mode.
To configure Slave mode:
1. Make sure that KEY PULSE SETUP MODE is either SLAVE or AUTO
2. Under KEY PULSE
HARDWARE
CONFIGURATION select the
Hardware type.
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 41 of 92
DRX INSTALLATION MANUAL
3. If HARDWARE
TYPE selected is
Custom, set the required trigger threshold level.
THRESHOLD
VALUE indicates a sensitivity level to the input signal.
4. If the KP signal coming in is inverted select the
INVERT POLARITY
option.
5. Under
SLAVE CONFIGURATION
select which key pulse inputs DRX should transmit on. One, both or neither key pulse input can be used.
NOTE: The input signal activity can be indicated using the DETECTED RATE
(ppm) and DUTY CYCLE monitors.
5.2.6.2. Configuring Key Pulse Master
In MASTER mode the DRX will transmit a key pulse signal based off the time of the DRX transmit pulse. Equipment connected to DRX as slaves will transmit relative to this key pulse.
To configure MASTER mode:
1. Make sure that KEY PULSE SETUP mode is set to MASTER .
2. Enable the Key pulse transmit under the KEY
PULSE OUTPUT
CONFIGURATION .
3. Select time of key pulse relative to DRX transmit time. The % value indicates the relative time between DRX Txs.
NOTE: The output signal activity can be indicated using the DETECTED RATE
(ppm) and DUTY CYCLE monitors..
NOTE: Pulse Width is only used for Advanced Key Pulse Setting, described in section
“5.2.6.4. Advanced Key Pulse” on page 43.
Page 42 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
DRX INSTALLATION MANUAL
5.2.6.3. Configuring Key Pulse Blanking
Rx Blanking allows any data during the key pulse input period to be blanked out so that potential interference is removed. This blanking will also remove potentially useful acoustic return.
To configure Rx blanking:
1. Under KEY PULSE
HARDWARE
CONFIGURATION select the
HARDWARE TYPE .
2. If HARDWARE
TYPE selected is
Custom set the required trigger threshold level.
3. If the KP signal coming in is inverted select the
INVERT POLARITY
option.
4. Enable the blanking using the BLANK
ENABLE selections.
5. The blanked region can be offset from the key pulse input signal using the HOLD OFF selection.
NOTE: The input signal activity can be indicated using the signal rate and duty cycle monitors.
5.2.6.4. Advanced Key Pulse
Advanced key pulse functionality can be enabled by applying the AKP license under
SYSTEM FEATURES .
The advanced key pulse functionality includes:
»
KP TIMEOUT ; If no key pulse is identified over a given period DRX will revert to standard operation.
»
JITTER ; Jitter can be configured in order to decorrelate transmit while maintaining synchronisation through key pulse operation.
Jitter Slot width for key pulse output is controlled by the PULSE WIDTH SETTING under KEY PULSE OUTPUT CONFIGURATION .
JITTER SLOT PADDING can be used to increase the width of Jitter Slots.
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 43 of 92
DRX INSTALLATION MANUAL
»
SLAVE TRIGGER HOLD OFF ; Tx can be delayed and staggered relative to the key pulse in.
»
PING PONG ; This mode forces time division between equipments’ full
Tx/Rx cycle.
.
»
IDLE KP MUTE : If KEY PULSE
OUTPUT is enabled and DRX is not pinging, on timeout key pulse will be output at 250Hz allowing slaved devices to continue running.
IDLE
KP MUTE selection will disable this mode
NOTE: The positive and negative edges of the key pulse output can be used to key two systems that would otherwise interfere with each other. The 2 edges of the key pulse are decorrelated in time.
NOTE: You must select COMMIT to apply these settings.
5.2.7. PPS Tab
PPS input can be configured from the PPS tab.
PPS can be configured for the sensor that is supplying time data as long as that sensor also supports PPS out.
DRX INSTALLATION MANUAL
NOTE: The Time data sensor that has been selected under DATA SETUP is indicated under PPS Setup. This needs to correspond with the PPS Port selected.
NOTE: You must COMMIT or these settings will be lost.
With correct configuration TIME will update and status will proceed from Disabled, red indicator, to Training, amber indicator, to synchronised, green indicator, as the following shows:
Figure 23. DRX Setup, PPS Tab
The following parameters need to be set:
»
PPS PORT.
»
TRIGGER EDGE ; Typically this is rising edge for PPS.
Page 44 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 45 of 92
Page 46 of 92
wassp.com
DRX INSTALLATION MANUAL
Figure 24. PPS Status
With PPS operating correctly status indicator will remain on green.
5.2.8. Geoids Tab
To use GPS height for calculating sea level in the DRX the GPS should be configured to supply an accurate height fix using Differential or RTK. GGA field 6, GPS Quality Indicator needs to be at 2 or above.
Sea level height can be configured to be relative to the internal GPS Geoid or relative to the Geoid file loaded into the DRX.
Doc: DRX Installation
Version: 5.0 June 2018
DRX INSTALLATION MANUAL
5.2.8.1. Configuring Height Relative to the DRX Geoid File
The DRX Geoid file for the appropriate region needs to be uploaded to the DRX. DRX
Geoid files are available on request from WASSP Support through the WASSP Support
Portal,
see “Appendix E - Product Registration, Support and Resources” on page 89.
If the required Geoid file is not available a request can be made through the WASSP
Support Portal.
To upload a DRX Geoid file:
1. BROWSE and select an appropriate DRX
Geoid File.
2. Select UPLOAD to upload the
DRX Geiod File to the DRX.
3. Uploaded Geoid files will be available in the AVAILABLE GEOIDS section.
4. Select the applicable
Geoid file and select
LOAD
. This will become the current Geoid used by DRX.
5. Select
GEOID FILE
CORRECTION and hit
COMMIT
.
The
CURRENT GEOID
will now be used for compensating for sea level change or tidal height when correcting the Bathymetry level.
If required an offset can be applied to the Geoid file. This can be applied under the DATA
SETUP tab in the DRX SETUP WEBPAGES .
See “Appendix C - Sea Level Height using GPS Height” on page 84
, section Sea Level
Height using DRX Geoid File for details on the calculated sea height using DRX Geoid
File.
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 47 of 92
DRX INSTALLATION MANUAL
5.2.8.2. Configuring Height Relative to the Internal GPS Geoid
The internal GPS Geoid can be used if a DRX Geoid file is not available for your area.
Deselect GEOID FILE CORRECTION and hit COMMIT .
An offset can be applied to the Internal GPS Geoid. This can be applied under the DATA
SETUP tab in the DRX SETUP WEBPAGES .
See “Appendix C - Sea Level Height using GPS Height” on page 84
Height using Internal GPS Geoid for details on the calculated sea height using Internal
GPS Geoid.
DRX INSTALLATION MANUAL
5.3. COMMISSIONING STEP 3: ON WATER PATCH TESTS
On water patch tests are essential for correctly configuring the DRX. The accuracy of the values derived from these patch tests will directly impact system performance.
These patch tests can be run using various tools including those in 3rd Party application such as HYPACK, WASSP Patch Test Utility shipped with WASSP CDX or manually through
WASSP CDX. The sections below describe methods for running patch tests manually using WASSP CDX.
5.3.1. GPS Time Delay
Most GPS sources used in conjunction with WASSP will have a significant delay between when the ship passes through a position and when that position is sent on the serial port.
This delay may be in the order of 1 second. This means at 10 knots an object will move
10 metres if passed in opposite directions at this speed.
IMPORTANT NOTE: NMEA Buffer and multiplexers can add significant delays to serial data. Any configuration change will require recalculation of delays. All connections from sensors should be direct to DRX..
NOTE: If using PPS input to synchronise to UTC time (configured through the DRX SETUP WEBPAGES) the GPS time delay will be automatically accounted for, and the GPS Patch Test is not required.
Test 1: For use with standard GPS
To perform this test, find a distinct feature such as a big rock, sharp slope or cable.
1. Run over the distinct object at SOG (e.g. 5kts).
Page 48 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
Figure 25. GPS Time Delay Stage 1
2. Run back over object in the opposite direction, same SOG (e.g. 5kts) and drop a mark on the same spot.
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 49 of 92
DRX INSTALLATION MANUAL
Figure 26. GPS Time Delay Stage 2
3. Use the measure tool to measure the difference between the object’s position in the direction the vessel traveled. If the object appears earlier than the previous pass, the time delay is positive.
DRX INSTALLATION MANUAL
4. The delay adjustment is added to the current Time Lag (Sec) value in the DATA
SETUP section of the DRX SETUP WEBPAGES .
See “5.2.4. Data Setup Tab” on page
Test 2: For use with DGPS
The advantage of this approach over the previous test is that it will eliminate pitch errors.
However, the displacement of the object will be smaller and this will be difficult to measure accurately as GPS errors can make this impossible.
Approach the distinct feature from the same direction at two vastly different known speeds, as close to zero and at the fastest mapping speed. If the object moves by
delta
metres further along the vessel track (+ve) at a faster speed the adjustment to the time delay will be: adjustment =
( - late / + early ) 2 x
delta
(fast speed in knots) - (slow speed in knots)
5.3.2. Roll Offset
Before attempting a roll patch test it is suggested that the GPS Time lag and any latencies are accounted for. Also, it is recommended that you conduct a preliminary adjustment of the Sound Speed settings to get things in the correct ballpark. Configure the mapping width to be at the maximum 120° for best results.
The WASSP Patch Test Utility, shipped with CDX, can be used to automatically calculate and apply Roll Offset. Alternatively, Roll Offset can be manually calculated.
Manual Roll Patch Test
1. Use the local chart and local knowledge to identify a spot for the roll patch test – ideally a flat area between 20-40m (shallower than 10m will make it hard to get an accurate reading).
2. Run the ship along a line in direction
A
(it may help to run with the tide and wind behind the vessel as the return journey is the important one).
3. Turn the ship and make a return journey
B
so that the same area is mapped but where the exact opposite heading is used. It may help to use the Heading Up and
COG functions.
Figure 27. GPS Time Delay Stage 3
The formula below outlines this process. adjustment =
( - late / + early ) change in position in metres speed in knots used in both directions
Page 50 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 51 of 92
Figure 29. Measurement of Swath Width H
Page 52 of 92
wassp.com
DRX INSTALLATION MANUAL
Figure 28. Manual Roll Patch Test
NOTE: Showing path
A
and path
B
overlapping. Measurement D is the change in the depths (2.8m in this case) between the edges of swaths.
4. Use the WASSP CDX Profile tool to measure the depth displacement between the edges of the swath on one side. This value is
D
. It will help to stop pinging while making the measurement so that the swath does not get overwritten.
5. Measure the entire width of the swath at the point you have measured the displacement. This value is
H
(73.229m in this case).
Doc: DRX Installation
Version: 5.0 June 2018
DRX INSTALLATION MANUAL
NOTE: the measurement is the distance of the line in this case rather than the depth change – this depth change across the swath is not used.
6. Use a calculator (one is present in Windows) to compute tan(
a
) (
D/H
) e.g. a. Run window Calculator, Select ‘View: Scientific Mode’ b. Enter
D
(e.g. 2.8) c. Press ‘/’ d. Enter
H
(e.g. 73.23m) e. Press ‘=’ f. Select ‘Inv’ g. Press ‘tan
-1
‘ h. Record this number as the Patch Roll Quantity
7. To compute the sign (positive roll or negative roll) of the Roll patch look at the
Starboard side-track as journey B is made.
If this is shallower than track A then the sign for the roll offset is positive. If this is deeper then the depths from track A the sign for the roll offset is negative.
8. Enter the Roll offset value computed into the Roll Offset setting in the
DATA SETUP section of the DRX SETUP WEBPAGES .
See “5.2.4. Data Setup Tab” on page 37.
9. Repeat these steps in a different area, or on a different Mapping database. If there is still a significant difference > 50cm add any difference generated to the Roll offset already computed and then test again. It should be possible to generate a roll offset within 0.1 degrees.
5.3.3. Pitch Offset
If GPS time delay can be completed using variable speed,
See ‘Test 2 For use with DGPS’
“5.3.1. GPS Time Delay” on page 49
then attempt to compute pitch offset as follows:
Pitch Correction
Requires: >10m depth, Distinct Object, DGPS or better,
Accurate Time Lag.
1. Once the Time Lag is accurately ascertained using the variable speed method described in the previous commissioning step, a Pitch Correction value can be ascertained by having the Ship travel over a distinct object in opposite directions.
2. The object will move if the Pitch offset is incorrect and the use of trigonometry will determine the Pitch offset between the Motion Sensor and the Transducer.
3. Enter this number into the Pitch Offset in the DATA SETUP section of the DRX SETUP WEBPAGES .
Figure 30. Pitch Corrections
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 53 of 92
DRX INSTALLATION MANUAL
5.3.4. Heading Offset
Requires: DGPS or better, Distinct Object and >10m depth.
To determine an accurate heading correction between the heading sensor and the transducer orientation we need high accuracy position sensors and corrected seafloor data.
1. Approach a small, distinct seafloor feature so that the port side of the swath covers the object.
2. Pass over the object so that the starboard side of the swath crosses the same object in the opposite direction. It is important that these two tracks are on exactly parallel heading lines.
3. Use basic trigonometry to calculate the required heading offset that will allow the object to remain stationary. Redo the heading test to check that the heading offset was entered correctly.
DRX INSTALLATION MANUAL
6 CONTROL AND DISPLAY APPLICATION SUPPORT
The DRX system is supported by a number of PC and/or Tablet based applications for
DRX control and data post processing, data storage and data visualisation.
For detailed operating instruction refer to the applications’ appropriate user manual.
Supported applications and connection procedures are outlined here.
NOTE: DRX SDK and API with integration instructions are available from
WASSP Ltd.
6.1. CONNECTING THE WASSP CDX TO THE DRX
WASSP CDX ships free with DRX and can be installed directly from the USB Flash Drive.
1. After installing WASSP CDX on your PC, start the DRX and run WASSP CDX .
2. WASSP CDX will automatically select the DRX as long as the network has been correctly configured.
3. To manually select the DRX you wish to connect to:
Open the
HOME
menu and select
DEVICES
.
NOTE: Navigation to DEVICES will depend on CDX version. tan( α ) = -d/(2w)
α = tan-1 (-d/2)
If object moves as above the sign is negated otherwise remove the -ve sign from this equation.
4. Enter the calculated value for
a
into the Heading Offset in the DATA SETUP section of the DRX SETUP WEBPAGES .
See “5.2.4. Data Setup Tab” on page 37.
5.3.5. Patch Test Validation
With on water patch tests complete the configuration can be checked.
1. Find an area with distinct features such as sand waves, depth variance, rocks etc
2. Map the area with parallel overlapping tracks in both directions.
3. Validate alignment of the features.
Any misalignment will be due to inaccuracies in the commissioning values that have been applied.
Page 54 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
4. The DEVICES page displays the current (or previous) connection. Press the
CHANGE button and a drop-down list of available connections will be displayed.
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 55 of 92
DRX INSTALLATION MANUAL
5. Select your desired connection.
6. The connection light will display the following depending on the current status of the connection:
»
GREEN: Connected
»
AMBER: Connection is being changed
»
RED: No Connection
NOTE: Refer to WASSP CDX Operators Manual for more details.
DRX INSTALLATION MANUAL
6.2. CONNECTING MAXSEA TIMEZERO PLOT TO THE DRX
TimeZero Plot needs to be purchased from Maxsea, see http://www.maxsea.com/ products/software
After installing the TZ Professional software on your PC, start the configured DRX and ensure that all connected sensors are on and sending data.
1. Open the
CONNECTION
WIZARD .
2. Select ‘Manual Port
Configuration’ and press the NEXT button.
3. Select ‘Add/
Configure
TCP WASSP
Connection’.
Page 56 of 92
wassp.com
4. Enter in the IP address of the DRX and the TCP port (default is 55555).
NOTE: If you don’t know the IP address of the DRX, use the ‘Find My DRX’ app to locate it.
5. The TZ Professional software should find all the data being output from the DRX. If not, recheck your network settings.
Doc: DRX Installation
Version: 5.0 June 2018
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 57 of 92
DRX INSTALLATION MANUAL DRX INSTALLATION MANUAL
6.3. CONNECTING HYPACK TO THE DRX
HYPACK needs to be purchased from your local HYPACK dealer. See www.hypack.com for details.
Install HYPACK 2016A or later. Refer to HYPACK manual for details.
1. Go to
PREPARATION and select
HARDWARE
SETUP .
6. Select your desired sources for each connected sensor.
NOTE: Navigation sources can be different from the DRX, but this may make installation simpler to use the DRX as the primary source.
2. INCLUDE
HYSWEEP Survey.
NOTE: All GPS and sensor data should be connected to the DRX.
DRX supplies all required data to HYPACK over the ethernet link.
NOTE: Refer to Knowledge Base for guidelines on system configuration with HYPACK.
See “Appendix E - Product Registration, Support and
7. To begin logging on to TZ Professional software, ensure that PBG icon is enabled.
Page 58 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 59 of 92
3. Select HYSWEEP
SURVEY in the tree on the left.
4. Then select WASSP
DRX
.
5. Select ADD
(WASSP DRX will now be in the list of Installed devices).
6. Close HYPACK
Combined
Hardware and save changes.
7. Select SURVEY in the menu.
8. Select HYPACK
SURVEY AND
HYSWEEP SURVEY .
9. Once connection is established DRX control can be performed through the WASSP
DRX CONTROL accessed from
HYSWEEP
TOOLS menu.
DRX INSTALLATION MANUAL DRX INSTALLATION MANUAL
7 OUTLINE DRAWINGS
7.1. DRX-32 OUTLINE DRAWINGS
111
20.50
6.60
260
R5.75
Page 60 of 92
“5.1. Commissioning Step 1: Ship
need to be applied in HYPACK directly.
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
Figure 31. DRX-32 Dimensions
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 61 of 92
DRX INSTALLATION MANUAL DRX INSTALLATION MANUAL
Figure 32. DRX-32 Front Plate Dimensions
Page 62 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
Figure 33. DRX-32 Back Plate Dimensions
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 63 of 92
7.2. DRX-46 OUTLINE DRAWINGS
DRX INSTALLATION MANUAL DRX INSTALLATION MANUAL
132.50
265.00
377.00
20.50
155
175
Figure 34. DRX-46 Assembly
Page 64 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
Figure 35. DRX-46 Front Plate Dimensions
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 65 of 92
Figure 36. DRX-46 Back Plate Dimensions
Page 66 of 92
wassp.com
DRX INSTALLATION MANUAL
Doc: DRX Installation
Version: 5.0 June 2018
DRX INSTALLATION MANUAL
8 DRX INTERCONNECTION
8.1. DRX-32 INTERCONNECTION
WHITE
BLACK
1
6
7
8
4
5
2
3
LAN
TD_P
TD_N
RD_P
NC
NC
RD_N
NC
NC
1
2
POWER
DC +VE
DC -VE
BARE
RED
BLACK
WHITE
BLUE
3
4
5
1
2
N2K
SHIELD
NET S
NET C
NET-H
NET-L
BLACK
BROWN
WHITE
BLUE
RED
GREY
YELLOW
GREEN
6
7
4
5
8
1
2
3
0183
NMEA0183 IN-A/+
NMEA0183 IN-B/-
NMEA0183 OUT-A/+
NMEA0183 OUT-B/-
GND (SHIELD)
PPS_IN
PPS_IN GND
NC
6
7
8
9
10
3
4
1
2
5
AUX
KP1_IN
KP1_IN_GND
KP2_IN
KP2_IN_GND
KP1_OUT
+5.5V Isolated
GND(5.5V,KPI_OUT)
REMOTE_PWR_ON
REMOTE_PWR_ON_GND
NC
Figure 37. DRX-32 Interconnection Diagram
BROWN
BLUE
WHITE
GREEN
YELLOW
GREY
7
8
9
5
6
3
4
1
2
RS422-A
PPS (AUX)
RxD A/+
RxD B/-
TxD A/+
TxD B/-
GND
NC
9-32V+
9-32V-
7
8
5
6
9
10
11
3
4
1
2
12
RS422-B
PPS (AUX)
RxD A/+
RxD B/-
TxD A/+
TxD B/-
GND
RESERVED
RESERVED
RESERVED
RESERVED
9-32V-
9-32V+
BLUE
GREEN
YELLOW
BLACK
RED
WHITE
3
4
1
2
5
6
RS232
RS232_TX
RS232_RX
RS232_GND
NC
9-32V+
9-32V-
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 67 of 92
DRX INSTALLATION MANUAL
8.2. DRX-46 INTERCONNECTION
WHITE
BLACK
7
8
5
6
3
4
1
2
LAN
TD_P
TD_N
RD_P
NC
NC
RD_N
NC
NC
1
2
POWER
DC +VE
DC -VE
BARE
RED
BLACK
WHITE
BLUE
3
4
1
2
5
N2K
SHIELD
NET S
NET C
NET-H
NET-L
BLACK
BROWN
WHITE
BLUE
RED
GREY
YELLOW
GREEN
3
4
1
2
5
6
7
8
0183
NMEA0183 IN-A/+
NMEA0183 IN-B/-
NMEA0183 OUT-A/+
NMEA0183 OUT-B/-
GND (SHIELD)
PPS_IN
PPS_IN GND
NC
1
6
7
8
9
10
4
5
2
3
AUX
KP1_IN
KP1_IN_GND
KP2_IN
KP2_IN_GND
KP1_OUT
+5.5V Isolated
GND(5.5V,KPI_OUT)
REMOTE_PWR_ON
REMOTE_PWR_ON_GND
NC
1
2
3
4
FAN
12V+
12V+
12V-
12V-
BROWN
BLUE
WHITE
GREEN
YELLOW
GREY
1
6
7
8
4
5
2
3
9
RS422-A
PPS (AUX)
RxD A/+
RxD B/-
TxD A/+
TxD B/-
GND
NC
9-32V+
9-32V-
5
6
7
3
4
1
2
8
9
10
11
12
RS422-B
PPS (AUX)
RxD A/+
RxD B/-
TxD A/+
TxD B/-
GND
RESERVED
RESERVED
RESERVED
RESERVED
9-32V-
9-32V+
BLUE
GREEN
YELLOW
BLACK
RED
WHITE
3
4
1
2
5
6
RS232
RS232_TX
RS232_RX
RS232_GND
NC
9-32V+
9-32V-
Figure 38. DRX-46 Interconnection Diagram
Page 68 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
DRX INSTALLATION MANUAL
9 TECHNICAL SPECIFICATIONS
DRX Spec Sheet
System
- Frequency
- Signal Type
- Tx Type
- Ping Rate
- Depth Range
Variable, Wideband, Transducer Dependent
DRX-32, WSP-603-20X; FM
DRX-46, WSP-603-25X; FM/CW
DRX-32, WSP-603-20X; Full Digital
DRX-46, WSP-603-25X; Digital
Automatic, depth determined; Maximum 50Hz
Transducer and environmental dependent. Nominally:
DRX-32, WSP-603-20X; 1-200m (WMB160). 2-450m (WMB80)
DRX-46, WSP-603-25X; 1-400m (WMB160). 2-600m (WMB80)
Maximum 2cm -Range Resolution
I/O Interface
- Ethernet
- Serial
- CAN
- Analog
- Other
Data Formats
- Input Sentences
- Output Sentences
- Output Data types
GbE
RS-232, RS-422 x 2 (model dependent), NMEA 0183
NMEA 2K
KP in x2, KP out, PPS
Remote Power Control, Fan Power out 12V x2 (model dependent)
See “Appendix B - Supported Sensors and Sentences” on page 82
See “Appendix B - Supported Sensors and Sentences” on page 82
See WASSP DRX ICD (Interface documentation for DRX and associated
DRX SDK/API documentation)
Power
- Power Supply
- Power Consumption (max)
DC Input
DRX-32, WSP-603-20X; 9-32V DC
DRX-46, WSP-603-25X; 18-32V DC
DRX-32, WSP-603-20X; 30W
DRX-46, WSP-603-25X; 50W
Mechanical
- Dimensions
- Weight
DRX-32, WSP-603-20X; DRX377mm(L) x 260mm(W) x 132mm (H)
DRX-46, WSP-603-25X; DRX377mm(L) x 260mm(W) x 175mm (H)
DRX-32, WSP-603-20X; 8.3kg
DRX-46, WSP-603-25X; 9.5kg
Bulkhead or Flat - Mounting
Environmental
- Operating Temperature DRX-32, WSP-603-20X; 0 o
C to 50 o
C
- Storage Temperature
- Ingress/Water Impact*
- Humidity/Damp Heat
- Vibration
- Shock
- EMC
DRX-46, WSP-603-25X; 0 o C to 40 o C
-20 o C to 85 o C
IP53, Bulkhead Mounted
IEC60945
+40°C 93 % relative humidity
DRX-32, WSP-603-20X; “IEC60945 Sweep 2 Hz – 13,2 Hz at ± 1 mm, 13,2
Hz – 100 Hz at 7 m/s2 and for 2 h on each resonance, otherwise 2 h at
30 Hz in all three axes”
DRX-32, WSP-603-20X; MIL-STD-901, Grade B, Class II
IEC60945
*Extended ingress rating to IP67 available; model WSP-603-205
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 69 of 92
DRX INSTALLATION MANUAL
10 APPENDIX
APPENDIX A - CABLE DRAWINGS
APPENDIX A.1 TRANSDUCER RX
een / drain wi
Scr
Gr een and Gr
Orange and Orange / White
Brown and Br
Blue and Blue Whit own / White een / White e
The CAT5E cables used in the transducer cable follow standard
CAT5 colour codes but the RJ-45 plug wiring is specific to the DRX and does NOT conform to T568A or B.
RJ-45 Plug
Pin Number
1
4
5
2
3
6
7
8
Case
CAT 5 conductor colour
Orange
Orange / White
Green
Green / White
Blue
Blue / White
Brown
Brown / White
Screen / drain wire (solder)
Pin #8
Pin #1
The screen / drain wire should be soldered on to the side of the RJ-45 connector. Scratch the side of the connector with something sharp before soldering to assist with the join.
Page 70 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
DRX INSTALLATION MANUAL
APPENDIX A.2 TRANSDUCER CABLE RESTRAINER
The supplied cable restrainer must be fitted to ensure that transducer connections are not damaged due to strain from the transducer cable. Ensure that when mounted there is still room to remove the cables from the DRX for servicing.
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 71 of 92
DRX INSTALLATION MANUAL
APPENDIX A.3 TRANSDUCER TX
Transmitter Cable Socket Assembly
If the transmitter cable socket needs to be disassembled, use the locking ring tightening tool (supplied with the DRX) to loosen the locking ring. To assemble the 3-pin sealed plug:
Push the following parts over the transmitter wires:
•
Gland Nut
•
Gland Cage
•
Gland
•
Main Body
Locking Ring
Tightening Tool
Gland Locking Cap Gland Nut
Main Body Gland Cage
Locking
Ring
Socket
1. Attach the RED or WHITE wire to L, the BLACK wire to N, and the GREEN wire to E on the socket and tighten all three screws.
BLACK
E
GREEN
BLACK
E
GREEN
N L
N
L
WHITE
Later Cable Colour Code
2. Push the socket into the main body, making sure that the flat on the socket locates into the flat on the main body.
3. Using the tightening tool, screw the locking ring into the front of the socket until tight.
4. Push the gland, gland cage, and gland nut into the main body as far as it will go and tighten the nut securely.
RED
Early Cable Colour Code
Tightening tool
Page 72 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
DRX INSTALLATION MANUAL
APPENDIX A.4 RS-232
Connector
RS-232
4
5
2
3
PIN Function
1 RS-232_TX
RS-232_RX
RS-232_GND
9-32V+
6 9-32V-
Marker identifies pin 1.
View: Looking into the socket on the
DRX. Wiring view of cable side on plug.
Example Connection:
1 RS-232_TX
2 RS-232_RX
3 RS-232_GND
4
5 9-32V+
6 9-32V-
RS-232_TX
RS-232_RX
RS-232_GND
»
Isolation; Fully electrically isolated.
»
Cable; Multi core or multi core screened with tinned copper conductors.
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 73 of 92
DRX INSTALLATION MANUAL
APPENDIX A.5 RS-422-A
Connector
RS422-A
4
5
6
2
3
PIN Function
1 PPS (AUX)
RxD A/+
RxD B/-
TxD A/+
TxD B/-
GND
7
8
9
9-32V+
9-32V-
Example Connection:
1 PPS (AUX)
2 RxD A/+
3 RxD B/-
4 TxD A/+
5 TxD B/-
6 GND
7
8 9-32V+
9 9-32V-
Marker identifies pin 1.
View: Looking into the socket on the
DRX. Wiring view of cable side on plug.
PPS OUT
TxD A/+
TxD B/-
RxD A/+
RxD B/-
PPS OUT GND
»
Isolation; Fully electrically isolated.
»
Cable; Multi core screened with tinned copper conductors.
»
Shield; Should be connected at far end.
1
9
7
2
8
3 4 5
6
NOTE: Depending on sensor compliance, this may be used as direct NMEA 0183 input.
DRX INSTALLATION MANUAL
APPENDIX A.6 RS-422-B
Connector
RS422-B
4
5
6
2
3
PIN Function
1 PPS (AUX)
RxD A/+
RxD B/-
TxD A/+
TxD B/-
GND
7
8
9
10
11
12
RESERVED
RESERVED
RESERVED
RESERVED
9-32V-
9-32V+
Example Connection:
1 PPS (AUX)
2 RxD A/+
3 RxD B/-
4 TxD A/+
5 TxD B/-
6 GND
7 RESERVED
8 RESERVED
9 RESERVED
10 RESERVED
11 9-32V-
12 9-32V+
View: Looking into the socket on the
DRX. Wiring view of cable side on plug.
PPS OUT
TxD A/+
TxD B/-
RxD A/+
RxD B/-
PPS OUT GND
»
Isolation; Fully electrically isolated.
»
Cable; Multi core screened with tinned copper conductors.
»
Shield; Should be connected at far end.
3
2
4
1
11
5
10
9
12
8
7
6
NOTE: Depending on sensor compliance, this may be used as direct NMEA 0183 input.
Page 74 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 75 of 92
DRX INSTALLATION MANUAL
APPENDIX A.7 NMEA 0183
Connector
0183
6
7
8
4
5
2
3
PIN Function
1 NMEA0183 IN A/+
NMEA0183 IN B/-
NMEA0183 OUT A/+
NMEA0183 OUT B/-
GND (Shield)
PPS_in
PPS_in GND
Marker identifies pin 1.
View: Looking into the socket on the
DRX. Wiring view of cable side on plug.
Example Connection:
6
7
4
5
8
1
2
3
NMEA0183 IN A/+
NMEA0183 IN B/-
NMEA0183 OUT A/+
NMEA0183 OUT B/-
GND (Shield)
PPS_in
PPS_in GND
NMEA0183 IN A/+
NMEA0183 IN B/-
NMEA0183 OUT A/+
NMEA0183 OUT B/-
PPS OUT +
PPS OUT GND
»
Isolation; Input electrically isolated. Output isolation, if required, should be at receive end.
»
Cable; Multi core screened with tinned copper conductors.
DRX INSTALLATION MANUAL
APPENDIX A.8 REMOTE POWER
Connector
AUX
6
7
8
9
10
4
5
2
3
PIN Function
1 KP1_in
KP1_in_GND
KP2_in
KP2_in_GND
KP1_OUT
+5.5V Isolated
GND(5.5V,KP1_OUT)
REMOTE_PWR_ON
REMOTE_PWR_ON_GND
View: Looking into the socket on the
DRX. Wiring view of cable side on plug.
3
4
1
2
5
6
7
8
9
10
Example Connection:
KP1_in
KP1_in_GND
KP2_in
KP2_in_GND
KP1_OUT
+5.5V Isolated
GND(5.5V,KP1_OUT)
REMOTE_PWR_ON
REMOTE_PWR_ON_GND
Page 76 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 77 of 92
DRX INSTALLATION MANUAL
APPENDIX A.9 KP1/KP2 IN
Connector
AUX
A Key Pulse (KP) can be connected to/from the sensor port of the DRX connection plate.
Input can detect a short circuit in addition to a voltage ranging from 0 - 15 V. See “KP (Key
Pulse) Settings” operating the WASSP system with a key pulse.
6
7
8
9
10
4
5
2
3
PIN Function
1 KP1_in
KP1_in_GND
KP2_in
KP2_in_GND
KP1_OUT
+5.5V Isolated
GND(5.5V,KP1_OUT)
REMOTE_PWR_ON
REMOTE_PWR_ON_GND
View: Looking into the socket on the
DRX. Wiring view of cable side on plug.
Example Connection:
5
6
7
8
3
4
1
2
9
10
KP1_in
KP1_in_GND
KP2_in
KP2_in_GND
KP1_OUT
+5.5V Isolated
GND(5.5V,KP1_OUT)
REMOTE_PWR_ON
REMOTE_PWR_ON_GND
»
Isolation; Fully electrically isolated.
»
Drive; Selectable as high, low or auto.
KP H
KP C
DRX INSTALLATION MANUAL
APPENDIX A.10 KP1 OUT
Connector
AUX
6
7
8
9
10
4
5
2
3
PIN Function
1 KP1_in
KP1_in_GND
KP2_in
KP2_in_GND
KP1_OUT
+5.5V Isolated
GND(5.5V,KP1_OUT)
REMOTE_PWR_ON
REMOTE_PWR_ON_GND
View: Looking into the socket on the
DRX. Wiring view of cable side on plug.
Example Connection:
6
7
8
9
10
1
4
5
2
3
KP1_in
KP1_in_GND
KP2_in
KP2_in_GND
KP1_OUT
+5.5V Isolated
GND(5.5V,KP1_OUT)
REMOTE_PWR_ON
REMOTE_PWR_ON_GND
»
Isolation; Fully electrically isolated.
KP IN H
+VIN
KP IN C
NOTE: For DRX serial numbers below #360 please refer to WASSP DRX
Installation Manual Version 4.0, as output isolation, if required, should be at receive end.
Page 78 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 79 of 92
DRX INSTALLATION MANUAL
APPENDIX A.11 POWER CONNECTION
Connect the cable assembly to appropriate DC power supply and connect to the
POWER connector located on the connection end of the DRX.
See below for connection details.
Pin No.
Colour
1 ( + ) Red or Clear
2 ( - ) Black
Marker identifies pin 1.
View: Looking into the socket on the DRX.
Wiring view of cable side on plug.
NOTE: Recommended Fuse/Circuit Breaker ratings:
DRX WSP-603-20X; DRX-32
Peak current at 12V is 3A
Peak current at 24V is 1.5A
Recommended 5A to 10A Breaker
DRX WSP-603-250; DRX-46
Peak current at 24V is 12A
Recommended 15A Breaker
APPENDIX A.12 ETHERNET
Standard Gigabit Ethernet.
Std T568A wiring:
7
8
5
6
3
4
1
2
TP1+
TP1 -
TP2 +
TP3 +
TP3 -
TP2 -
TP4 +
TP4 -
DRX INSTALLATION MANUAL
APPENDIX A.13 NMEA2K
Connector
N2K
4
5
2
3
PIN Function
1 SHIELD
+12V
GND
NET-H
NET-L
Marker identifies pin 1.
View: Looking into the socket on the DRX.
Wiring view of cable side on plug.
»
Isolation; Fully electrically isolated.
»
Standard DeviceNet, “NMEA 2000 Approved”.
APPENDIX A.14 FAN
Depending on DRX Model, an optional FAN can be added to assist cooling the DRX in high temperature environments. The fan connector has two 12V outputs that are switched on when the DRX is turned on/off.
2
3
PIN Function
1 12V +
4
12V +
12V –
12V –
Marker identifies pin 1.
View: Looking into the socket on the DRX.
Wiring view of cable side on plug.
»
Voltage; Regulated.
»
Current should not exceed 1A.
Page 80 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 81 of 92
DRX INSTALLATION MANUAL
APPENDIX B - SUPPORTED SENSORS AND SENTENCES
The following tables show sensors and sentences currently supported by DRX. This is not a definitive list and is updated as required.
Device
Furuno SC30/SC50
SMC IMU-108
Trimble GPS
Hemisphere V103
Spatial IMU
SMC IMU-008
Valeport MiniSVS/
MiniSVP
Valeport Midas
AML Xchange
Configuration
Position and heading via IF-NMEASC Interface unit
Select Sentence #7 when configuring the IF-NMEASC port. This will output ATT, HVE, GGA, VTG and ZDA NMEA sentences. Set baud rate to 38400bps and interval to 25ms.
Roll, pitch, heave, TSS1
Position, heading, speed, TNL GGK, HDT, VTG sentences
Position and heading; GGA, HDT, ZDA, VTG
Roll, Pitch, Heave; TSS1
Roll, Pitch, Heave; TSS1
Valeport Real Time format;
Sound Velocity<TAB> Units<CR><LF>
Xchange Format;
Sound Velocity<CR><LF>
Table 1. Supported Sensors
NMEA 0183 and serial sentences supported by DRX:
NMEA / Serial
Sentence
GGA
GLL
GNS
PTNL GGK
RMC
ZDA
HDG
HDT
HDM
PFEC ATT
PFEC HVE
TSS1
PASHR
VTG
MTW
AML SVS
Valeport SVS
Description
GPS Position Fix and related data
Position, Latitude/Longitude
GNSS position fix data and related data
Trimble Geographic Position
Navigation Information; Position, Track Made Good and Speed Over
Ground
Time and date
Magnetic Heading
True Heading
Heading Magnetic
True heading (Furuno proprietary sentence), optionally pitch and roll
Heave (Furuno proprietary sentence)
Roll, pitch, heave
Roll, pitch, heave, heading
Track Made Good and Ground Speed
Water Temperature
Sound Velocity, see Supported Devices
Sound Velocity, see Supported Devices
Table 2. Supported NMEA / Serial Sentences
Page 82 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
DRX INSTALLATION MANUAL
NMEA 0183 sentences output by DRX. Sentences are output from the NMEA 0183 port at
1Hz.
NMEA
DBT
DBS
DBK
Description
Depth Below Transducer
Depth Below Surface
Depth Below Keel
Table 3. NMEA Sentences Output
NMEA 2K Description
None currently supported.
Table 4. Supported NMEA 2K Sentences
Points to Note:
»
Satellite Compass with PPS output will improve system timing and simplify commissioning.
»
IMU performance will be improved with Satellite Compass input. Depending on IMU,
Satellite Compass input may be required for accurate attitude data.
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 83 of 92
DRX INSTALLATION MANUAL
APPENDIX C - SEA LEVEL HEIGHT USING GPS HEIGHT
APPENDIX C.1 SEA LEVEL HEIGHT USING DRX GEOID FILE
GPS Antenna
GPS Z
XDCR Z
R
AW = Antenna Height from
WGS-84 Ellipsoid
(GGA field 9+11)
* GGA field 6 must be
higher than 1
Down = negative
All in meters
Water Level
XDCR DRAFT
RTK Tide
DRX Geoid File
XDCR
Chart Datum
WGS-84 Ellipsoid
GEOID OFFSET
(set in DATA SETUP)
RTK Tide =
AW + DRX GEOID FILE - GPS Z - XDCR Z + XDCR DRAFT + GEOID OFFSET
APPENDIX C.2 SEA LEVEL HEIGHT USING INTERNAL GPS GEOID
GPS Antenna
GPS Z
AG = Antenna Height MSL
(GGA field number 9)
* GGA field 6 must be higher than 1
Down = negative
All in meters
R
XDCR Z
Water Level
XDCR DRAFT
XDCR
RTK Tide
Internal GPS Geoid
Chart Datum
WGS-84 Ellipsoid
GEOID OFFSET
(set in DATA SETUP)
RTK tide = AG - GPS Z - XDCR Z + XDCR DRAFT + GEOID OFFSET
Page 84 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
DRX INSTALLATION MANUAL
APPENDIX C.3 ENABLING GPS HEIGHT FOR SEA LEVEL HEIGHT
RTK
tide mode can be enabled in CDX under the
TIDE CONTROL.
NOTE: To enable RTK tide mode in other applications refer to the appropriate manual.
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 85 of 92
APPENDIX D - IMS CONTROL IN CDX
IMS can be turned on in CDX under DRX PROCESSING .
DRX INSTALLATION MANUAL DRX INSTALLATION MANUAL
APPENDIX E - DRX INTERCONNECT CHANGE HISTORY
Back Panel 1
Up to DRX #50
Back Panel 2
DRX #51 to #216
Back Panel 3
DRX #217+
Back Panel 4
DRX #360+
Back Panel 5
DRX #389+,
DRX-46 #1+
Function Pin Function Pin Function Pin Function Pin Function Pin
RS422-A
RS-422,
PPS
6
RS-422,
PPS
9
RS-422,
PPS, DC
9-32V
9
RS-422,
PPS,
DC 9-32V
9
RS-422,
PPS,
DC 9-32V
9
RS422-B n/a n/a -
RS-422,
PPS
12 RS-422, PPS 12
RS-422,
PPS,
DC 9-32V
12
RS232
RS-232,
Remote PWR
6 RS-232 6
RS-232,
DC 9-32V
6
RS-232, DC
9-32V
6
RS-232,
DC 9-32V
6
0183
AUX
FAN -
DRX-46
NMEA0183,
PPS
8
NMEA0183,
PPS
8
NMEA0183,
PPS
8
NMEA0183,
PPS
8
NMEA0183,
PPS
KP In,
KP Out,
PPS
8
KP In,
KP Out,
Remote PWR
8
KP In,
KP Out,
Remote PWR
8
KP In, KP Out
(Isolated)
KP-EXT-SW,
Remote PWR
10
KP In, KP Out
(Isolated)
KP-EXT-SW,
Remote PWR
8
10
12V x 2 4
Manual
Reference
Version 1.1
Version 2.0
Version 4.0
Version 4.2
Version 5.0
Page 86 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 87 of 92
DRX INSTALLATION MANUAL
APPENDIX F - GLOSSARY
Term Description
LAN
LED
PPS
RTK GPS
RX
TX
WASSP CDX
XDCR
GbE
HDG
IMU
KP
DHCP
DRX-32
DRX-46
DRX Setup Webpages
Dynamic Host Configuration Protocol, for automatically providing IP addresses.
DRX model used with S3 And F3 product models.
DRX model used with F3X product models.
Webpages that DRX provides for configuration, setup, installation, upgrading.
Gigabit Ethernet.
Heading.
Inertial Motion Unit/Motion Sensor, typically for roll, pitch and heave.
Key Pulse, typically used to synchronise sonar/sounder transmit timing.
Local Area Network.
Light Emitting Diode.
Pulse Per Second, used for synchronising time, typically to UTC through GPS.
Real Time Kinematic GPS, used for high quality positioning.
Receive.
Transmit.
WASSP PC application for control, visualisation and post processing of DRX data.
Transducer.
DRX INSTALLATION MANUAL
APPENDIX G - PRODUCT REGISTRATION, SUPPORT
AND RESOURCES
WARRANTY
DRX products are covered with a one year limited warranty. In order to be covered by the warranty, the WASSP DRX must be registered with WASSP Ltd. The product warranty registration form can be filled in online by going to: http://wassp.com/product-warranty-registration/
TECHNICAL SUPPORT
If you require maintenance and/or repair contact your local dealer. A list of WASSP dealers and distributors is available at wassp.com.
DRX technical support is available directly through:
»
Online: http://wassp.com/support/ and click on ‘Request Support’
LATEST RESOURCES
»
For the latest version of manuals: http://wassp.com/support/ and click on ‘Manuals’
»
For software updates and release notes: http://wassp.com/support/ and click on
‘Request Support’
»
For Knowledge Base: http://support.wassp.com:8095/display/KB/
»
For System drawings, mechanical drawings and declarations of conformity: http://wassp.com/support/ and click on ‘Request Support’
Page 88 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 89 of 92
YOUR NOTES
DRX INSTALLATION MANUAL DRX INSTALLATION MANUAL
YOUR NOTES
Page 90 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018
Doc: DRX Installation
Version: 5.0 June 2018
wassp.com
Page 91 of 92
DRX INSTALLATION MANUAL
Page 92 of 92
wassp.com
Doc: DRX Installation
Version: 5.0 June 2018