User Manual

Waterproof Price

Computing Scale

YSP

© EXCELL PRECISION CO., LTD. 2013. All rights reserved worldwide.

The information contained herein is the property of EXCELL PRECISION CO., LTD. and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorized by contract or other written permission. The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied.

EXCELL PRECISION CO., LTD.

TABLE OF CONTENTS

INSTRUCTION FOR USE ...................................................................................................... 2

PREPARATION BEFORE USING........................................................................................... 3

CHAPTER 1 PRODUCT INTRODUCTION............................................................................. 5

1-1 F

EATURE

........................................................................................................................ 5

1-2 S

PECIFICATION

................................................................................................................ 5

1-3 E

RROR

M

ESSAGES

.......................................................................................................... 6

1-4 S

CREEN

D

ISPLAY

............................................................................................................. 6

1-5 P

OWER

S

UPPLY

............................................................................................................... 7

CHAPTER 2 KEYBOARD FUNCTION ................................................................................... 8

CHAPTER 3 OPERATION INSTRUCTION ............................................................................ 9

3-1 I

NTERNAL

V

ALUE

D

ISPLAY

M

ODE

....................................................................................... 9

3-2 S

ETTING UP

B

ACKLIGHT

M

ODE

(

OPTION

)............................................................................ 9

3-3 S

ETTINGS OF

P

RICING

U

NIT

.............................................................................................. 9

3-4 E

XTERNAL

W

EIGHT

C

ALIBRATION

.................................................................................... 10

3-5 E

XTERNAL

W

EIGHT

F

ACTORY

D

EFAULT

S

ETTING

.............................................................. 10

CHAPTER 4 FUNCTION SETTING...................................................................................... 11

4-1 F3

S

TABILIZATION

(O

NE OF JUDGEMENT CONDITIONS

)

R

EADING

T

IMES

...................... 13

4-2 F4

S

TABILIZATION

(O

NE OF JUDGMENT CONDITIONS

)

R

ANGE

..................................... 13

4-3 F5

C

LEAR

U

NIT

P

RICE

I

MMEDIATELY

A

FTER

.......................................................... 14

4-4 F6

S

WITCHING

-

ON

U

NIT

M

ODE

S

ETTING

..................................................................... 14

APPENDIX 1 7-SEGMENT DISPLAY CHARACTERS ......................................................... 15

01007021

1

ZSME100000075

EXCELL PRECISION CO., LTD.

Thank you for purchasing Price Computing Scale. In order to operate smoothly, to last the durability, and to reduce the chance of breakdown for this product, please read this Manual carefully.

Instruction for Use

1. In order to prevent the scale from dust and static electricity, please fix the dustproof cover on the scale with double-sided adhesive.

2. Please keep the scale in a cool and dry place. Do not store at high temperatures or damp places.

3. Please keep the scale clean and free from insect infestation.

4. To avoid impact and it is to be used under designated pressure (the weight put on the platter can not exceed the maximum capacity of the scale).

5. If the scale is not going to be used for some time, please clean it and store it in a plastic bag in dry condition. A desiccant sachet may be included to prevent moisture build up. The scale should be recharged every 3 months to prevent failure of the internal rechargeable battery.

6. Please operate or charge the scale in an open area. Do not squeeze the power cord to avoid wire on fire.

7. The commodity should be placed in the center of platter for accurate weighing. The dimension of the weighted commodity should not exceed the dimension of platter.

8.

Please do not use your hand and sharp things to touch the waterproof film, in order to protect the scale.

01007021

2

ZSME100000075

EXCELL PRECISION CO., LTD.

9.

10.

4

1

push

2

3

Please push the clip to take off the dust cover to clean

If you want, you can use the four screws to lock the platter so that it will be more firm.

When you lock ,please follow the order “1 → 2 → 3 → 4”

Preparation Before Using

1. Put the scale on a firm level surface free for accurate weight readings. Adjust the four leveling feet to get the leveling bubble at the centre of circle.

2. Scale must be used under a stable temperature and stable air flow. Avoid direct sunlight onto the scale or near the exhaust port of ventilating system.

3. Scale must be used under individual socket to avoid the interference of other

electric appliances.

4. Remove any weight that might be on the platter before the scale is switched on.

5. Please note that when or needs to be recharged.

6. Introduction of Storage Battery symbol appears on the screen, the scale

01007021

3

ZSME100000075

EXCELL PRECISION CO., LTD.

Due to the storage battery adopt the advanced free-maintaining technique, customers need not to replenish electrolyte.

The scale should be recharged every 3 months to prevent failure of the internal rechargeable battery.

1. The battery should be charged for 8~10 hours.

2. The temperature of battery should below 45

.

Maintaining

1. Please do not discharge with over-current when using the battery. Please charge the battery after discharging current.

2. Please take down the battery when the scale is not used for a long time or break the connection of cathode.

3. Do not short the battery terminals to check whether there is current. Please check whether the connection point is firm to guarantee good connection.

4. The battery should be replaced by specialized person.

No reverse-battery or the product will be damaged.

a) Anode of battery should be connected with Anode of product battery

( usually red cable

) b) Cathode of battery should be connected with Cathode of product battery (usually brown cable or black cable) c) See the picture following

Brown cable(or black cable) connected with Anode of battery

Red cable connected with

Cathode of battery

Safety warnings

1. The electrolyte of battery is caustic which causes metal, cotton, etc to corrode.

2. The hydrogen will be resolved when using or charging the battery and it will cause explosion when approaches fire.

01007021

4

ZSME100000075

EXCELL PRECISION CO., LTD.

Chapter 1 Product Introduction

1-1 Feature

‹

Sealed waterproof silica gel strip blocks water from infiltrating into the scale.

‹

Surrounded by waterproof grade sheeting to ensure the water free.

‹

1/3,000~1/6,000 display resolution available.

‹

Aluminum frames coated with anti-corrosion treatment for longer lifespan.

‹

Stainless steel made feet and platter for anti-rusted.

‹

LCD display with LED Backlight makes readings clear and readable at night.

‹

High speed of 24bits AD fast reacts and shortens the weighing operation duration.

‹

Selectable units: Kilogram (kg), gram (g), ounce (oz), and pound (lb) weighing units available.

‹

Built-in rechargeable battery can be easily replaced.

‹

Vertical placement design battery prevents from electrolyte leakage, and makes more safety and durable.

‹

Low power indication and auto power off.

‹

Well-designed protection point for transportation.

‹

Securable platter with screws at users' needs.

1-2 Specification

MODEL CAPACITY DIVISION (single range) DIVISION (multi-range)

YSP-6 6kg

1g

2g

0kg~3kg/1g

3kg~6kg/2g

YSP-15 15kg

YSP-30 30Kg

2g

5g

5g

10g

0kg~6kg/2g

6kg~15kg/5g

0kg~15kg/5g

15kg~30kg/10g

Operating Temperature:

-10°C ~ +40°C

Dimensions:

250.4 x 144 x 313 mm ( W x H x D)

Weight of the scale:

Around 3kg

01007021

5

ZSME100000075

EXCELL PRECISION CO., LTD.

144mm

313mm

250.4mm

1-3 Error Messages

The weight value is over 9 division of maximum capacity.

Zero value above 10% full scale.

Zero value below 10% full scale.

The internal value is over 350,000.

The internal value is below 80,000.

- - - - -

If the negative weight is over 20 divisions and there is no T or PT, the display shows “- - - - - -”

 

 

1-4 Screen Display

WEIGHT  

0

← 

 

 

NET  

 

M+  

 

.

.

.

.

.

.

 

 

UNIT   PRICE  

.

.

.

.

.

.

.

.

.

.

.

.

     

TOTAL   PRICE $  

Display Column

1. Weight

6 digits in total display the weight on platter.

The left digit is able to display the negative symbol.

 

 

 

 

 

$/kg

01007021

6

ZSME100000075

EXCELL PRECISION CO., LTD.

2. Unit Price

6 digits in total display the unit price of objects on platter.

The decimal point floats two digits.

3. Total Price

6 digits in total display the total price of the objects on platter or the accumulation.

Symbol Display

1.

Z

: “Zero”

2.

T

: “Tare”

3.

M+

: “Accumulation”

4. :

Low battery.

1-5 Power Supply

Power Selection

1. 6 V / 4 Ah Rechargeable battery

2. 110 / 220 V ±15 % AC Main power

Recharge Voltage

1. AC 110 V +10%, -15%

2. AC 220 V +10%, -15%

Power Consumption

29mA (system+L/C

; no backlight,single display) about 138 hours

29mA (system+L/C

; no backlight,dubble display) about 138 hours

33mA (system+L/C

; backlight, single display) about 121 hours

41mA (system+L/C

backlight,dubble display) about 90 hours

Low Power Alarm

When the ( ) symbol keeps flashing on the left down corner of the display, it need charging.

The indicator will turn off automatically after 5 ~ 10 hours (approximately 1 ~ 2 hours with backlight on), when the low battery warning symbol shows up. The indicator must be fully charged, before operating again.

When the low battery warning symbol shows up, please recharge the indicator immediately for fear of weight instability.

01007021

7

ZSME100000075

EXCELL PRECISION CO., LTD.

Chapter 2 Keyboard Function

0 ~ 9 :

Number key. Press the keys to input the numbers (0 ~ 9) and to set unit price.

CE :

Press the key to clear the old unit price and then input the new one if you would like to change the unit price (If the unit price has been input for 3 seconds, you can input the new one immediately).

1 T 1 :

Press the key to deduct the containers’ weight and the symbol “ ◄ ” in Weight will appear.

1 Z 1 :

Weight return to zero

1 . 1 :

Press this key one time, the

DECIMAL POINT

is available. Press this key two times with number key 1, 2, 3 or 4,

PRICING UNIT

function is available.

00 :

Press this key to enter “00”

Q’TY :

When there is more than one piece of the same item, such as cans which are priced by quantity, input the unit price first and then press

Q’TY

to enter the number of items (input an integer no more than 999). The total amount will be shown in

TOTAL PRICE

(as same as the calculator’s multiply). At that moment, please press

+

to store it in accumulation.

1 + 1 :

Input unit price in the

UNIT PRICE

, then press

+

to memorize the sum.

M+ :

After the number on

TOTAL PRICE

is stable, press M+ to memorize the sum.

MR :

If there is accumulation data in memory, please press

MC

continually to display the last 99 data.

MC :

When there is accumulation data in memory (accumulation symbol “ ◄ ” displays in

TOTAL PRICE

), press this key to clear all accumulation data, and accumulation symbol “ ◄ ” disappears.

CH :

Press

CH

, then total price disappears in

TOTAL PRICE

. Please press the payment of customer, and the change displays in the

UNIT PRICE

.

20key keyboard

4 5 6 + MR

0 . CE Z T

01007021

8

ZSME100000075

EXCELL PRECISION CO., LTD.

Chapter 3 Operation Instruction

3-1 Internal Value Display Mode

Press Z key, when the display show “ ” ,then, press CE key immediately. The display will show internal value. Press 0 to exit the internal value mode and return to the weighing mode.

3-2 Setting up Backlight Mode (option)

<

Method 1

>

Press

Z

key, the display will show “ away. It is “auto-backlight mode”.

” ,then press

4

key right

Press

Z

key, the display will show “ away.

It is “backlight-off mode”.

<

Method 2

>

”, then press

Press 0 key for 2 seconds, the beeper will beep …three times.

The scale will change to backlight mode

“Auto-backlight mode” or “backlight-off mode”.

5

key right

Auto-backlight mode

When there is a weight on the pan which weight is over 10d or pressing any keys, the backlight will be on. After back to zero for 10 desonds (the weight is under

10d,), backlight will be off

The scale will keep the auto-backlight mode after the next bootup, if the auto-backlight mode is set before last power-off.

3-3 Settings of Pricing Unit

n

Selecting the pricing unit:

Double press key, the display will show the current pricing unit:

 

WEIGHT   UNIT   PRICE  

 

 

0

← 

 

NET  

 

M+  

 

 

 

 

 

 

 

 

 

$/kg

     

TOTAL   PRICE $  

 

01007021

9

ZSME100000075

EXCELL PRECISION CO., LTD.

o

Press 1 ~ 6 to select pricing units. The scale will be back to weighing & price mode.

The display will show the symbol indication “ ◄ ” for the request pricing unit.

1

kg 2

100g 3

HK catty

4

tl.T 5

⇒ lb

If the price unit

“ lb

" is seleteced, the displaying will show three symbols

3

.

If the price unit

“ oz

" is selected, the displaying will

not

show any symbol

3

.

3-4 External Weight Calibration

Steps

1. Make sure the scale backs to zero and is in “kg” mode.

2. Press MC key and do not release, the then press

.

key to show

“ ” , the weight display “ . ” kg .

3. Release two keys.

4. Key-in pre-calibration weight, the display will show “pre-calibration” of weight value in flash. Place full weight(s) on the pan. When the scale is stable, take off the weight(s) from the pan. The calibration finished.

3-5 External Weight Factory Default Setting

To Return to the factory setting, hold MC key and press CE key.

After buzzer beep sound, release two keys.

The scale will return to factory setting.

01007021

10

ZSME100000075

EXCELL PRECISION CO., LTD.

Chapter 4 Function Setting

Press MC key do not release, and turn power on to enter function setting mode.

 

WEIGHT   UNIT   PRICE  

 

 

 

 

 

0

← 

 

NET  

 

M+  

 

0

← 

 

 

 

   

 

 

pressTkey

WEIGHT  

 

TOTAL   PRICE $  

UNIT   PRICE  

 

 

3 seconds

 

 

 

 

 

 

 

$/kg

$/kg

⇒ reserved

⇒ reserved

⇒ reserved

⇒ Stabilization(Reading

Times)

⇒ Stabilization (Range)

⇒ Clear Unit Price

Immediately After

 

 

NET  

 

M+  

 

   

 

pressTkey

WEIGHT  

TOTAL   PRICE $  

9600

 

UNIT   PRICE  

 

 

 

 

Switching-on Unit Mode

Setting

⇒ reserved

⇒ reserved

⇒ reserved

 

 

0

← 

 

 

NET  

 

M+  

 

   

 

 

 

 

TOTAL   PRICE $  

 

 

 

 

$/kg

Rs232 closed pressTkey

WEIGHT   UNIT   PRICE  

 

 

 

0

← 

 

NET  

 

 

M+  

 

   

 

 

 

 

TOTAL   PRICE $  

 

 

 

 

 

$/kg

pressTkey

 

 

 

0

← 

 

NET  

 

 

M+  

 

   

WEIGHT  

 

 

UNIT   PRICE  

 

 

TOTAL   PRICE $  

 

 

 

 

 

$/kg

01007021

11

ZSME100000075

EXCELL PRECISION CO., LTD.

 

 

 

 

 

 

 

 

 

 

 

 

0

← 

 

 

NET  

 

M+  

 

   

0

← 

 

NET  

 

 

M+  

 

   

0

← 

 

NET  

 

 

M+  

 

   

0

← 

 

NET  

 

 

M+  

 

   

pressTkey

WEIGHT  

 

 

pressTkey

WEIGHT  

 

 

pressTkey

WEIGHT  

 

 

UNIT   PRICE  

 

 

TOTAL   PRICE $  

Unit price reserved

UNIT   PRICE  

 

 

TOTAL   PRICE $  

Close kg

 

 

 

 

 

$/kg

 

 

 

 

 

$/kg

UNIT     WEIGHT  

 

 

QUNTITY  

 

 

 

 

 

$/kg

pressTkey

WEIGHT  

 

 

UNIT   WEIGHT  

 

 

QUNTITY  

 

 

 

 

 

$/kg

pressTkey

 

 

 

0

← 

 

NET  

 

 

M+  

 

   

WEIGHT  

 

 

UNIT     WEIGHT  

.

.

.

.

.

.

.

.

.

.

.

.

QUNTITY  

Press T key, return to F1

 

 

 

 

 

$/kg

01007021

12

ZSME100000075

EXCELL PRECISION CO., LTD.

4-1 F3

Stabilization

(One of judgement conditions)

Reading Times

 

WEIGHT   UNIT   PRICE  

 

 

0

← 

 

 

NET  

 

M+  

 

 

 

 

 

 

 

 

$/kg

     

TOTAL   PRICE $  

 

Press number key from

2 ~ 9

to select 0~9

2~ 9

Reading times “2 ~ 9”

Default setting

6 times

Press T to go to next setting mode.

Press M+ to save setting values. The scale will count backwards to zero and back to weighing mode from exiting setting mode.

4-2 F4

Stabilization

(One of judgment conditions)

Range

 

WEIGHT   UNIT   PRICE  

 

 

0

← 

 

NET  

 

 

M+  

 

 

 

 

 

 

 

 

$/kg

     

TOTAL   PRICE $  

 

Press number key 0 , 1 , 2 , 3 to select 0 ~ 3

0

1/4 d

1

1/2 d

2

3/4 d

3

1 d

Press T to go to next setting mode.

Press M+ to save setting values. The scale will count backwards to zero and back to weighing mode from exiting setting mode.

01007021

13

ZSME100000075

EXCELL PRECISION CO., LTD.

4-3 F5

Clear Unit Price Immediately After

 

WEIGHT   UNIT   PRICE  

 

 

0

← 

 

NET  

 

 

M+  

 

 

 

 

 

 

 

 

$/kg

     

TOTAL   PRICE $  

 

Press number key 0 , 1 to select 0 or 1

0

Unit price reserved.

1

Clear unit price immediately.

(Press to clear unit price immediately in accumulation mode and change mode.)

Press T key to enter the next setting mode.

Press M+ key to save setting values and exit the setting mode. The scale will count backwards to zero and return to the weighing mode from exiting setting mode.

4-4 F6

Switching-on Unit Mode Setting

 

WEIGHT   UNIT   PRICE  

 

 

0

← 

 

 

NET  

 

M+  

 

 

 

 

 

 

 

 

$/kg

     

TOTAL   PRICE $  

 

Use the number key 0 , 1 to select a parameter from 0 or 1

0

The weighing unit remains the prior set mode *

*

Prior setting mode: If a certain switching-on unit is set, this unit will be the one at switching on.

If no unit is set, the unit at switching off last time will be the unit at switching on

1

The weighing unit is as switching on is always “kg”

Press T key to enter the next setting mode.

Press M+ key to save setting values and exit the setting mode. The scale will count backwards to zero and return to the weighing mode.

01007021

14

ZSME100000075

EXCELL PRECISION CO., LTD.

Appendix 1 7-Segment Display Characters

0

1

2

3

4

5

6

7

8

9

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

01007021

15

ZSME100000075

advertisement

Related manuals

Download PDF

advertisement