Beckhoff CP72 Series Installation And Operating Instructions Manual
Oglas
Oglas
Installation and Operating instructions for
“Economy” Panel PC CP72xx
Version: 2.1
Date: 2019-10-09
Table of contents
1. Foreword
Notes on the Documentation
Liability Conditions
Trademarks
Patent Pending
Copyright
State at Delivery
Delivery conditions
Description of safety symbols
Basic safety measures
Operator’s obligation to exercise diligence
Operator requirements
2. Product Description
Appropriate Use
Structure
Access to memory and battery
Interfaces
Power supply
Network connection
Additional plug-in cards (optional)
3. Installation Instructions
Transport and Unpacking
Transport
Unpacking
Installation of the Panel PC
Mounting arm installation
Earthing measures
Power Supply Connection
Beckhoff power supply technology
Pin assignment of the power supply connector
Pre-assembled cable sets for the power supply
Fitting the power supply cable with IP65 connector
Connecting Power Supply
Cable Cross Sections
Configuration for shutting down the PC
PC_ON and Power Status functions
Wiring diagram CP72xx
Wiring diagram CP72x4 with 24-inch display (discontinued)
Connecting the Network
Pre-assembled network cables
Fitting the network cable with IP65 connector
USB-interface (optional)
Pre-assembled USB-cables
Fitting the USB-cable with IP65 connector
RS232-interface (optional)
Pre-assembled serial interface cables
Fitting the RS232-interface cable with IP65 connector
Connecting devices
Connecting cables
Check voltage rating and connect
4. Operating Instructions
Switching the Industrial PC on and off
First switching on and driver installation
Keyboard codes
Maintenance
Cleaning the Industrial PC
Servicing
Replacing the battery on the motherboard
CP72xx
Table of contents
11
21
21
21
22
19
20
20
20
22
22
23
23
23
17
17
17
18
15
16
16
17
12
13
14
14
11
11
11
12
24
24
24
25
27
27
27
27
3
3
3
3
4
3
3
3
3
5
6
6
7
7
7
8
10
10
10
10
1
Table of contents
Emergency procedures
Shutting down
Disposal
5. UPS Software Components (optional)
Installation on the PC
Help files
6. Troubleshooting
Fault correction
Beckhoff Support & Service
Beckhoff branches and partner companies
Beckhoff Headquarters
Beckhoff Support
7. Appendix
Beckhoff Service
Assembly dimensions
Dimensions and total weight
8. Appendix
Technical data
Approvals
FCC: Federal Communications Commission Radio Frequency Interference
Statement
FCC: Canadian Notice
27
27
27
28
28
28
29
29
30
30
30
30
30
31
31
35
36
36
36
36
36
2 CP72xx
Foreword
CP72xx
Foreword
Notes on the Documentation
This description is only intended for the use of trained specialists in control and automation engineering who are familiar with the applicable national standards. It is essential that the following notes and explanations are followed when installing and commissioning these components.
The responsible staff must ensure that the application or use of the products described satisfy all the requirements for safety, including all the relevant laws, regulations, guidelines and standards.
Liability Conditions
The documentation has been prepared with care. The products described are, however, constantly under development. For that reason the documentation is not in every case checked for consistency with performance data, standards or other characteristics. In the event that it contains technical or editorial errors, we retain the right to make alterations at any time and without warning. No claims for the modification of products that have already been supplied may be made on the basis of the data, diagrams and descriptions in this documentation.
All pictures shown in the documentation are exemplary. Illustrated configurations can differ from standard.
Trademarks
Beckhoff ® , TwinCAT ® , EtherCAT ® , Safety over EtherCAT ® , TwinSAFE ® ,
XFC ® and XTS ® are registered trademarks of and licensed by Beckhoff
Automation GmbH.
Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owners.
Patent Pending
The EtherCAT Technology is covered, including but not limited to the following patent applications and patents: EP1590927, EP1789857,
DE102004044764, DE102007017835 with corresponding applications or registrations in various other countries.
The TwinCAT Technology is covered, including but not limited to the following patent applications and patents: EP0851348, US6167425 with corresponding applications or registrations in various other countries.
Copyright
© Beckhoff Automation GmbH & Co. KG.
The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express authorization are prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design.
State at Delivery
All the components are supplied in particular hardware and software configurations appropriate for the application. Modifications to hardware or software configurations other than those described in the documentation are not permitted, and nullify the liability of Beckhoff Automation GmbH &
Co. KG.
Delivery conditions
In addition, the general delivery conditions of the company Beckhoff
Automation GmbH & Co. KG apply.
3
Foreword
DANGER
WARNING
CAUTION
Attention
Note
Description of safety symbols
The following safety symbols are used in this operating manual. They are intended to alert the reader to the associated safety instructions.
Acute risk of injury!
If you do not adhere the safety advise adjoining this symbol, there is immediate danger to life and health of individuals!
Risk of injury!
If you do not adhere the safety advise adjoining this symbol, there is danger to life and health of individuals!
Hazard to individuals!
If you do not adhere the safety advise adjoining this symbol, there is obvious hazard to individuals!
Hazard to devices and environment
If you do not adhere the notice adjoining this symbol, there is obvious hazard to materials and environment.
Note or pointer
This symbol indicates information that contributes to better understanding.
4 CP72xx
Foreword
Only switch the PC off after closing the software
Basic safety measures
Before the Industrial PC is switched off, software that is running must be properly closed.
Otherwise it is possible that data on the storage medium is lost. Please read the section Switching the Industrial PC on and off.
Switch off all parts of the equipment, then uncouple the fieldbus
Attention
CAUTION
Attention
Before opening the housing of the PC, and whenever the PC is being used for purposes other than plant control, such as during functional tests following repair, all parts of the equipment must first be switched off, after which the Industrial PC can be uncoupled from the plant.
Pulling out the fieldbus connection plug uncouples the PC (optional).
Items of equipment that have been switched off must be secured against being switched on again.
The Industrial PC’s power supply unit must be supplied with 24V
DC
.
Do not open the power supply unit while voltage is applied!
The supply voltage must be switched off before the power supply unit housing is opened.
Do not exchange any parts when under power
When components are being fitted or removed, the supply voltage must be switched off.
Fitting work on the Industrial PC can result in damage:
• if metal objects such as screws or tools fall onto operating circuit boards.
• if connecting cables internal to the PC are removed or inserted during operation.
• if plug-in cards are removed or inserted when the PC is switched on.
High Voltage!
DANGER
Displays used for the Control Panel’s LC-display are operated with a voltage of up to 1000 V, depending on type. For that reason:
The supply voltage must be disconnected before the housing of the
Control Panel is opened.
CP72xx 5
Foreword
National regulations depending on the machine type
Operator’s obligation to exercise diligence
The operator must ensure that
• the Industrial PC is only used for its intended purpose (see chapter
Product Description ).
• the Industrial PC is only operated in a sound condition and in working order (see chapter Maintenance ).
• the Industrial PC is operated, maintained and repaired only by suitably qualified and authorized personnel.
• the personnel is instructed regularly about relevant occupational safety and environmental protection aspects, and is familiar with the operating manual and in particular the safety notes contained herein.
• the instruction manual is in good condition and complete, and always available for reference at the place of installation of the
Industrial PC.
• none of the safety and warning notes attached to the Industrial PC are removed, and all notes remain legible.
• every user is familiar with all the functions of the software installed on the Industrial PC to which he has access.
Depending on the type of machine and plant in which the Industrial PC is used, national regulations governing the controllers of such machines will apply, and must be observed by the operator. These regulations cover, amongst other things, the intervals between inspections of the controller.
The operator must initiate such inspections in good time.
Only trained persons may open the Industrial PC housing
Note
Procedure in the event of a fault
Read the operating instructions
Software knowledge
The operator is responsible for ensuring that only trained electrical staff opens the housing of the Industrial PC.
In the event of faults at the Industrial PC, the list in the section
Troubleshooting can be used to determine the measures to be taken.
Operator requirements
Anyone who uses the Industrial PC must have read these operating instructions.
Every user must be familiar with all the functions of the software installed on the Industrial PC to which he has access.
6 CP72xx
Product Description
Product Description
Appropriate Use
The CP72xx Panel PC with 3½” motherboard is designed for mounting behind a Beckhoff Control Panel. Cooling is achieved via heat sink structure between the Control Panel and the add-on PC. A fan inside the closed housing ensures that the heat is distributed evenly.
The Industrial PC is designed for mounting arm installation.
DANGER
Do not use the Panel PC in areas of explosive hazard!
The Panel PC must not be used where there is a risk of explosion.
Structure
Rear view of theCP72xx
1
2
1 1
2
1
Access to the connectors
In order to get access to the connectors, first unscrew the according M4cross-head screws ( 1 ) (see photo above). The plastic caps ( 2 ) can then be taken off easily.
View to the connectors
CP72xx
The picture shows the view to the connectors when the plastic caps are removed.
7
Product Description
Removing the drive cover
Access to memory and battery
View to the hard-disk drive
(optional) and the memory card
After unscrewing the two Allen screws (see arrows) the drive cover can be taken off.
1
+ pole
3
- pole
2
Removing the drive cover allows access to the IDE-hard-disk ( 1 ) (optional), the Compact-Flash-memory card ( 2 ) and the lithium battery of the system clock ( 3 ).
8 CP72xx
Removing the hard-disk drive and the memory card polarity
+ pole
- pole
Product Description
WARNING
WARNING
The hard-disk drive and the memory card can now be pulled out. Here, changing the lithium battery is also possible.
The installation takes place in reverse order.
Danger of Explosion!
Replace battery only with the identical type or an alternative type recommended by the manufacturer. Notice correct polarity!
Handling of Lithium Batteries
Lithium Batteries should not be recharged, exposed to fire, opened and they should be protected against sunlight and moisture.
CP72xx 9
Product Description
Power supply
Interfaces
Power supply
X101
Network connection
The power supply connection of the Industrial PC and the connection with the UPS (optional) is established via the power supply socket ( X101 ).
Network connection
X106
Type plate
The Ethernet-interface with RJ-45-connector ( X106 ) allows the PC to be connected to a network (LAN). In the basic configuration a Gigabit-port is available.
Additional plug-in cards (optional)
There are notes at the Industrial PC and in the connection area which provide information about the hardware configuration of the Industrial PC at the time it was supplied.
10 CP72xx
Installation Instructions
Installation Instructions
Please also refer to chapter Foreword .
Transport and Unpacking
The specified storage conditions must be observed (see chapter Technical data ).
Transport
Despite the robust design of the unit, the components are sensitive to strong vibrations and impacts. During transport, your Control Panel should therefore be protected from excessive mechanical stress. Therefore, please use the original packaging.
Danger of damage to the unit
Attention
If the device is transported in cold weather or is exposed to extreme variations in temperature, make sure that moisture (condensation) does not form on or inside the device.
Prior to operation, the unit must be allowed to slowly adjust to room temperature. Should condensation occur, a delay time of approximately
12 hours must be allowed before the unit is switched on.
Unpacking
Proceed as follows to unpack the unit:
1. Remove packaging.
2. Do not discard the original packaging. Keep it for future relocation.
3. Check the delivery for completeness by comparing it with your order.
4. Please keep the associated paperwork. It contains important information for handling the unit.
5. Check the contents for visible shipping damage.
6. If you notice any shipping damage or inconsistencies between the contents and your order, you should notify Beckhoff Service.
CP72xx 11
12
Installation Instructions
Note
Attention
Installation of the Panel PC
The Panel PC series CP72xx is designed for mounting arm installation. A
Control Panel is installed in the front of the IP65 Panel PC.
The ambient conditions specified for operation must be observed (see the section Technical data ).
Circulation of air
When the unit is installed in an enclosure, adequate space for ventilation and for opening the PC must be provided.
Please note the following points during installation of the PC:
• Position the PC in such a way that reflections on the screen are avoided as far as possible.
• Use the position of the screen as a guide for the correct installation height; it should be optimally visible for the user at all times.
• The PC should not be exposed to direct sunlight.
Avoid extreme environmental conditions
Extreme environmental conditions should be avoided as far as possible.
Protect the rear of your PC from dust, humidity and heat.
The clearance above and below the housing must be at least 20 cm in order to ensure adequate ventilation of the PC.
The cooling ribs of the PC must not be covered.
Rotatable mounting arm adapter
Rotatable and tiltable mounting arm adapter
(optional)
Mounting arm installation
The industrial PC is designed for mounting arm installation using a 48 mm diameter mounting arm tube. The case features an integrated rotatable mounting arm adapter.
The swivelling range of the tiltable mounting arm adapter (optional) amounts to approx. 45°.
~45°
CP72xx
Installation Instructions
Mounting arm installation For Installation the Industrial PC at the mounting arm, first push back the red ring cover ( 1 ) (see arrows).
Now you get access to the allen head screws ( 2 ), with which the mounting arm tube is fixed in the adapter.
2
1
Earthing measures
The picture shows the rotatable and tiltable mounting arm adapter
(optional).
Earthing measures
Earthing connections dissipate interference from external power supply cables, signal cables or cables to peripheral equipment.
CP72xx
The picture shows the earthing connection in the wiring area of the PC
(see arrow). The earthing cable is laid through the support arm.
13
Installation Instructions
Power Supply Connection
Supplied mains power unit The Industrial PC is fitted with a 24 V
DC
power supply unit .
Uninterruptible power supply (UPS)
Note
When the Industrial PC is provided with a power supply unit with integrated UPS (order option) you can realize an uninterruptible power supply (UPS) using the battery pack C9900-U330.
Danger of Explosion!
WARNING
Danger of Explosion if using other battery packs!
Schematic diagram of power supply unit wirings
Beckhoff power supply technology
Innovative solution for shutting down Industrial
PCs
Industrial PCs equipped with a UPS are in actual use frequently switched off by simply turning off the supply voltage. In this case the PC shuts down via the battery. However, over time this reduces the service life of the battery.
The new Beckhoff power supply technology approach addresses this problem and now offers the user the option of switching the PC off without the need for using the battery, thereby reducing the load on the battery.
In addition to the main switch this innovative solution uses an ON/OFF switch for the machine. Basically, the main switch remains switched on and provides the power supply for the PC during shutdown.
Once the PC has shut down, the PC power supply unit issues a signal to indicate that the process is complete and that the main voltage can be switched off. This can be done manually via a signal lamp connection or via a contactor. With this solution the main switch generally only has to be switched off if the control cabinet has to be opened.
14 CP72xx
Note
Installation Instructions
In order to maintain a screen display for the Industrial PC in the event of a power failure, the power supply unit is equipped with a UPS output for connecting a Control Panel. This enables a power failure to be visualised and displayed to the user. Once the PC has shut down, the UPS output is switched off in order to avoid total discharge of the battery.
Internal connection
The UPS output of the CP72xx power supply unit is internally connected with the panel
For a detailed functional description please refer to section Connecting
Power Supply .
Pin assignment of the power supply connector
X101
Connector 12-pole Coninvers RC-12P1N1126000
View connector-sided
The power supply connection of the Panel PC and the connection with the UPS (optional) is established via the 12-pole power supply socket ( X101 ). The protection class of the circular plug-in connector accords to the IP65-standard.
Wiring when using 8-core cables:
Pin Wire Function
1 1 -
2 2 +
3
4
3 ge/gn
NC
5
6
4
5
-
+
Battery Pack
(with UPS)
24 V DC Power Supply
1
2
3
4
Pin Wire Function
1, 8 -
2, 9 +
3 ge/gn
NC
5
6
4, 10 -
5, 11 +
Battery Pack
(with UPS)
24 V DC Power Supply
Pin Wire Function
7 6 PC_ON
8 7 Power-Status
9
10
-
-
NC
NC
11
12
-
-
NC
NC
Wiring when using 12-core cables:
To connect the power supply and the battery pack, 2 wires per pin are used when using 12-core cables to halve the voltage drop across the cable.
Pin Wire Function
7
8
9
10
6
7
-
-
PC_ON
Power-Status
NC
NC
11
12
-
-
NC
NC
CP72xx 15
Installation Instructions
Pin assignment for connecting the power supply, the switch and the battery pack (optional)
Pin assignment CP72x4 with 24-inch display (discontinued)
View connector-sided
Male connector
Connector 12-pole Coninvers
RC-12P1N1126000
Pin Wire Function
1
2
1
2
-
+
Battery Pack
(with UPS)
3 3
4 ye/gn
NC
5
6
7
4
5
6
-
+
PC_ON
24 V DC Power Supply
PC Unit
8
9
10
7
8
9
Power-Status
-
+
Battery Pack
(with UPS)
11
12
10 -
11 +
24 V DC Power Supply
Display
Pre-assembled power supply cables
Pre-assembled cable sets for the power supply
For easy installation of the power supply there are pre-assembled connection cables of different length and with IP65 connectors available
(see table).
Order number
C9900-K271
C9900-K272
C9900-K275
C9900-K276
C9900-K277
Denomination
Power supply cable IP65 for CP72xx, length 5 m, preassembled, M23-female connector, screwable, 8-wire, second end open
Power supply cable IP65 for CP72xx, length 10 m, preassembled, M23-female connector, screwable, 8-wire, second end open
Power supply cable IP65 for CP72x4 with 24-inch display, length 5 m, pre-assembled, M23-female connector, screwable, 12-wire, second end open
Power supply cable IP65 for CP72x4 with 24-inch display, length 10 m, pre-assembled, M23-female connector, screwable, 12-wire, second end open
Power supply cable IP65 for CP72xx up to 19-inch display, length 20 m, pre-assembled, M23-female connector, screwable, 12-wire, second end open
Basic configuration without connecting cable and connector
Fitting the power supply cable with IP65 connector
In the basic configuration of the Industrial PC there is no connection cable provided for connecting the power supply. For connecting the power supply following connectors can be used:
Cable 8-pole for CP72xx
Coninvers female connector Series RC 12-pole
(Crimp Coninvers RM-12S1N8A1100, Coninvers Connector 12-pole, with metric screw connection M16)
Cable 12-pole for CP72x4 (discontinued)
Coninvers female connector Series RC 12-pole
(Crimp Coninvers RM-12S1N8A1300, Coninvers Connector 12-pole, with metric screw connection M20)
The connectors and special tools for the assembly are available via the company Coninvers http://www.coninvers.com
as well as different distributors.
16 CP72xx
Installation Instructions
Connecting Power Supply
The external wiring consists of the connection of the power supply, the battery pack (optional) and the connection of customised components for shutting down the PC.
Note cable cross sections, avoid voltage drop!
Cable Cross Sections
For the connection of the power supply, wiring with a cable-cross-section of 1.0 mm 2 must be used.
With bigger distances between voltage source and PC, you take the voltage drop as a function of the cable-cross-section as well as voltage fluctuations of your distribution voltage into account, so that is secured that the voltage doesn't fall under 22 V at the power supply.
Insert fuse
Attention
The power supply must be protected with maximum 10 A.
Configuration for shutting down the PC
The connections for shutting down the Industrial PCs are established via the PC_ON input and the Power Status output.
PC_ON and Power Status functions
• If the PC_ON input is connected to 24 V via a switch, the PC shuts down according to the rules. The PC_ON signal is inverted, i.e. the
PC shuts down if the 24 V connection is live.
• If the PC_ON input is NOT connected by the user, the PC can be booted in the familiar way by connecting the supply voltage and shut down via the battery by switching off the supply voltage.
Attention
Service life of the rechargeable battery
This procedure significantly reduces the service life of the rechargeable battery and should therefore not be used.
• Once the PC has shut down, the Power Status output is switched from 24 V to 0 V. Via this output a signal lamp can be connected or a contactor for de-energising the whole system. The maximum load for the Power Status output is 0.5 A and a suitable fuse should be provided.
CP72xx 17
Installation Instructions
Wiring diagram power supply and external wiring
Wiring diagram CP72xx
Wiring according to the wiring diagram (the circuit of PC_ON and Power-
Status is symbolical):
Note
Connection of the Battery Pack
Connection of the Battery Pack in combination with integrated UPS (order option).
18 CP72xx
Wiring diagram power supply and external wiring
Installation Instructions
Wiring diagram
CP72x4 with 24-inch display (discontinued)
Wiring according to the wiring diagram (the circuit of PC_ON and Power-
Status is symbolical):
Note
Connection of the Battery Pack
Connection of the Battery Pack in combination with integrated UPS (order option).
CP72xx 19
Installation Instructions
Connecting the Network
Pre-assembled network cables
Pre-assembled network cables
For easy installation of the network connection there are pre-assembled connection cables of different length and with IP65 – RJ45 connectors available (see table).
In addition to the specified network cables, cables for further configuration are available.
Order number Denomination
C9900-K281 Network cable for CP72xx, length 3 m, pre-assembled,
Harting-Push-Pull-Ethernet-connector IP65, second cable end RJ45 IP20
C9900-K282
C9900-K283
C9900-K284
C9900-K285
C9900-K286
C9900-K287
C9900-K288
Network cable for CP72xx, length 5 m, pre-assembled,
Harting-Push-Pull-Ethernet-connector IP65, second cable end RJ45 IP20
Network cable for CP72xx, length 10 m, pre-assembled,
Harting-Push-Pull-Ethernet-connector IP65, second cable end RJ45 IP20
Network cable for CP72xx, length 15 m, pre-assembled,
Harting-Push-Pull-Ethernet-connector IP65, second cable end RJ45 IP20
Network cable for CP72xx, length 20 m, pre-assembled,
Harting-Push-Pull-Ethernet-connector IP65, second cable end RJ45 IP20
Network cable for CP72xx, length 30 m, pre-assembled,
Harting-Push-Pull-Ethernet-connector IP65, second cable end RJ45 IP20
Network cable for CP72xx, length 40 m, pre-assembled,
Harting-Push-Pull-Ethernet-connector IP65, second cable end RJ45 IP20
Network cable for CP72xx, length 50 m, pre-assembled,
Harting-Push-Pull-Ethernet-connector IP65, second cable end RJ45 IP20
Basic configuration without network cable and connector
Fitting the network cable with IP65 connector
In the basic configuration of the Industrial PC there is a connector cap provided without connector.
For network connection following Harting Push Pull connector RJ45, 8-pole can be used:
• Connector RJ45 8-pole Harting Push Pull connector-set according to
IEC24702, white No. 09 45 145 1500
The connector and special tools for the assembly are available via the company Harting http://www.harting.de/ as well as different distributors.
20 CP72xx
Installation Instructions
USB-interface (optional)
Order option C9900-E187 Optionally a USB 2.0 interface with 4-pole-connector (M12-female connector IP65) in the connection area is available with order option
C9900-E187:
Order number
C9900-E187
Denomination
IP65 connector M12 in the wiring area of a CP72xx for one
USB 2.0 Port
Pin assignment for connecting the USBinterface (optional)
Pin assignment, view connector-sided
Pin Signal Color
1 VCC Red
2
3
D -
GND
White
Black
4 D + Green
Female connector 4-pole Escha 8029477
Pre-assembled USB-cables
Pre-assembled USB-cables For easy installation of the USB-interface in the wiring area there are preassembled USB-cables of different length and with IP65-connectors available (see table).
Usage of the Cables
Note
These USB-cables can not be used for connecting the following options:
• C9900-E190 (USB-A in the wiring area of a CP72xx for one USB 2.0
Port)
• C9900-E169 (2-port USB socket inside the Control Panel back plane)
Order number
C9900-K291
C9900-K292
Denomination
USB cable for CP72xx, length 3 m, assembled,
M12 connector IP65, screw type, 4 pin, second end USB-B connector
USB cable for CP72xx, length 5 m, assembled,
M12 connector IP65, screw type, 4 pin, second end USB-B connector
Required connector
Fitting the USB-cable with IP65 connector
For connecting the USB-interface the following connector is needed cablesided:
• Connector 4-pole round shield Binder 99142981404
For further information see http://www.binder-connector.de/.
CP72xx 21
Installation Instructions
RS232-interface (optional)
Order option C9900-E186 Optionally a RS232-interface with 12-pole-connector (M12-female connector IP65) is available in the connection area with order option
C9900-E186:
Order number
C9900-E186
Denomination
IP65-connector M12 in the wiring area of a CP72xx for one serial interface RS232
Pin assignment for connecting the RS232interface (optional)
Pin assignment, view connector-sided
SG 12-pole M12
Escha 8029505
4
5
6
7
8
Pin
1
2
3
9
10
11
12
Signal
DCD
RXD
TXD
DTR
SGND
DSR
RTS
CTS
RI
NC
NC
NC
Pre-assembled serial interface cables
Pre-assembled
RS232-cables
For easy installation of the serial interface in the wiring area there are preassembled RS232-cables of different length and with IP65-connectors available (see table).
Order number
C9900-K295
C9900-K296
C9900-K297
Denomination
Serial interface cable RS232 for CP72xx, length 3 m, assembled, M12 connector IP65, screw type, 12 pin, second end D-Sub 9 pin plug
Serial interface cable RS232 for CP72xx, length 5 m, assembled, M12 connector IP65, screw type, 12 pin, second end D-Sub 9 pin plug
Serial interface cable RS232 for CP72xx, length 10 m, assembled, M12 connector IP65, screw type, 12 pin, second end D-Sub 9 pin plug
Required connector
Fitting the RS232-interface cable with IP65 connector
For connecting the RS232-interface the following connector is needed cable-sided:
• Cable with connector M12 12-pole, 12x0,14mm² 5m Escha 8028494
For further information see http://www.escha.de/.
22 CP72xx
Attention
Attention
Installation Instructions
Connecting devices
Power supply plug
The power supply plug must be withdrawn!
Please read the documentation for the external devices prior to connecting them.
During thunderstorms, plug connector must neither be inserted nor removed.
When disconnecting a plug connector, always handle it at the plug. Do not pull the cable!
Connecting cables
The connections are located at the top of the Industrial PC and are documented in the Product Description chapter.
When connecting the cables to the Industrial PC, proceed according to the following sequence:
• Switch off all the devices that are to be connected.
• Disconnect all the devices that are to be connected from the power supply.
• Connect all the cables between the Industrial PC and to the devices that are to be connected.
• Connect all data transfer cables (if present) to the appropriate plug-in receptacles of the data/telecommunication networks.
• Reconnect all devices to the power supply.
Check voltage rating and connect
Fitted with the 24 V
DC
power supply unit:
1. Check that the external power supply is providing the correct voltage.
2. Insert the power supply cable that you have assembled into the
Industrial PC's power supply socket. Then connect it to your external 24 V power supply.
Use same type of rechargeable battery
If a 24 V UPS is installed, the same type of rechargeable battery must be used.
CP72xx 23
Operating Instructions
Operating Instructions
Please also refer to chapter Foreword.
Switch on
Shutting down and switching off
Attention
Switching the Industrial PC on and off
The Industrial PC does not have its own mains switch. The Industrial PC will start when the equipment is switched on, or when it is connected to the power supply.
When the plant is switched off, or when it is disconnected from its power supply, the Industrial PC will be switched off.
Control software such as is typically used on Industrial PCs permits various users to be given different rights. A user who may not close software may also not switch the Industrial PC off, since data can be lost from the hard disk by switching off while software is running.
First shut down, then switch off the PC
If the Industrial PC is switched off as the software is writing a file to the storage medium, the file will be destroyed. Control software typically writes something to the storage medium every few seconds, so that the probability of causing damage by switching off while the software is running is very high.
Attention
Switch off power supply
When you have shut down the Industrial PC, you have to switch off power supply for at least 10 seconds before rebooting the system.
After resetting power supply the PC will start booting automatically.
First switching on and driver installation
When you switch on the Industrial PC for the first time, the pre-installed operating system (optional) will be started. In this case, all the required drivers for any additional, optional hardware components ordered with the
PC will already have been installed.
If the PC was ordered without operating system, you have to install the operating system and the driver software for any auxiliary hardware yourself. Please follow the instructions in the documentation for the operating system and the additional devices.
24 CP72xx
Operating Instructions
Type-dependent number of keys
Operation
Home
L
Del
Ins
Pause
Enter
Esc
Shift
Caps
Lock
Ctrl Alt
Q
End
Pg Up Pg Dn
R
W
...
!
1
@
2
Keyboard codes
Depending on the precise type, the Control Panel can have fewer keys than those described here.
The cursor is the blinking character that marks the point at which the next character entered will be displayed. The cursor is also known as the insertion point. The cursor keys each move the cursor one place in the associated direction.
The Home key moves the cursor to the beginning of the line, while the End key moves it to the end of the line.
The Pg Up key scrolls one page back, the Pg Dn key scrolls one page forward.
The Tab key takes the cursor to the next input field, while Shift and Tab moves to the previous input field.
The mouse cursor can be moved over the screen with the aid of the touch screen or of the touch pad (optional). The keys correspond to the left and right hand keys of a Microsoft mouse.
The Del key deletes the character to the right of the cursor.
The Ins key causes characters to the right of the cursor to be overwritten.
The overwrite mode is cancelled by pressing the key again.
Print-Screen prints a hard copy of a text screen on the printer.
The Pause key stops the computer until another key is pressed (only under
MS-DOS).
Your input is confirmed with the Enter key.
Backspace deletes the character to the left of the cursor.
If the Shift key is pressed at the same time as another key, then instead of the numbers you obtain the character printed above the number, and you obtain upper case letters instead of lower case letters.
Pressing the Caps Lock key once activates and locks the Shift key.
Pressing the Shift key cancels this function.
Rather like the effect of the Shift key, Ctrl and Alt also change the meaning of another key that is pressed at the same time.
This key brings up the Start menu of the operating system in use (Windows
95, 98, ME, NT, 2000, XP).
Pressing this key opens the property sheet of the active (or marked) object.
The Esc key has the effect of closing dialog windows and of interrupting some of the computer’s working operations.
All other keys bring the character printed on them onto the display at the position of the cursor.
CP72xx 25
Operating Instructions
F1 F2 F3 F4
F5
F9
F6
F10
F7
F11
The meaning of the function keys, F1 to F10 , is determined by the software and is displayed at the bottom edge of the display.
F8
F12
The function of the special keys above the display is also determined by the software. The function is displayed at the top edge of the display.
The special keys each have an orange LED controlled by the software.
26 CP72xx
Maintenance
Please also refer to chapter Foreword .
Operating Instructions
Cleaning the Industrial PC
Attention
WARNING
WARNING
Disconnect from power supply
Switch off the Industrial PC and all connected devices, and disconnect the
Industrial PC from the power supply.
The Industrial PC can be cleaned with a soft, damp cloth. Do not use any aggressive cleaning materials, thinners, scouring material or hard objects that could cause scratches.
Servicing
The Industrial PC requires no maintenance.
Replacing the battery on the motherboard
A used battery on the motherboard has to be replaced. See also chapter
Access to memory and battery.
Danger of Explosion!
Replace battery only with the identical type or an alternative type recommended by the manufacturer. Notice correct polarity!
Handling of Lithium Batteries
Lithium Batteries should not be recharged, exposed to fire, opened and they should be protected against sunlight and moisture.
The used battery must be disposed of in accordance with national electronics scrap regulations.
Emergency procedures
In case of fire, the Industrial PC should be extinguished with powder or nitrogen.
Shutting down
Dismantling the Industrial
PC
Observe national electronics scrap regulations
Disposal
The device must be fully dismantled in order to dispose of it. The housing can be sent for metal recycling.
Electronic parts such as disk drives and circuit boards must be disposed of in accordance with national electronics scrap regulations.
CP72xx 27
UPS Software Components (optional)
UPS Software Components (optional)
Installing the UPS driver software
Installation
For operating the power supply unit as a UPS, the UPS driver software and the associated UPS driver must be installed on the Industrial PC.
On delivery of the Beckhoff Industrial PC with operating system the software is already installed. Should the software not be installed on your
PC, the drivers can be installed from the driver CD provided.
Installation on the PC
To install the UPS driver software, execute file
Beckhoff_UPS_vx.xx.xx.exe from the subdirectory of UPS\… from the
CD provided on the Industrial PC (Driver-archive for the Industrial-PC,
C9900-S700-xxxx) .
The program is self-extracting and will guide the user through the installation routine.
Beckhoff Information
System
Help files
The driver software comes with a detailed help function.
The help files can be called up either directly from the configuration register by clicking the Help button, or under via Start > Programs > Beckhoff >
UPS software components .
28 CP72xx
Troubleshooting
Troubleshooting
Please also refer to chapter Foreword.
Pixel errors
Note
Pixel errors in the TFT display are production-caused and represent no complaint-reason!
Fault correction
Fault Cause
Nothing happens after the Industrial
PC has been switched on
No power supply to the Industrial
PC
Other cause
The Industrial PC does not boot fully
Computer boots, software starts, but control does not operate correctly
Memory device error
Setup settings are incorrect
Other cause
Cause of the fault is either in the software or in parts of the plant outside the Industrial PC
Faulty memory device
USB error while TwinCAT access via USB
Cycle time in TwinCAT is set on
10 ms (standard)
The Industrial PC functions only partially or only part of the time, e.g. no or dark picture, but memory drive responds when switching on
Defective components in the
Industrial PC
Procedure
Check power supply cable.
Call Beckhoff Service
Check the setup settings
Call Beckhoff Service
Call the manufacturer of the machine or the software
Check memory in another device
Call Beckhoff Service
Increase the cycle time up to
50 ms till 80 ms
Call Beckhoff Service
CP72xx 29
Troubleshooting
Beckhoff Support & Service
Beckhoff and their partners around the world offer comprehensive support and service, guaranteeing fast and competent assistance with all questions related to Beckhoff products and system solutions.
Beckhoff branches and partner companies
Please contact your Beckhoff branch office or partner company for local support and service on Beckhoff products!
The contact addresses for your country can be found in the list of Beckhoff branches and partner companies: www.beckhoff.com
You will also find further documentation for Beckhoff components there.
Beckhoff Headquarters
Beckhoff Automation GmbH & Co. KG
Huelshorstweg 20
33415 Verl
Germany
Phone:
Fax: e-mail:
+49(0)5246/963-0
+49(0)5246/963-198 [email protected]
Beckhoff Support
Beckhoff offers you comprehensive technical assistance, helping you not only with the application of individual Beckhoff products, but also with wideranging services:
• worldwide support
• design, programming and commissioning of complex automation systems
• training program for Beckhoff system components
Hotline: +49(0)5246/963-157
Fax: e-mail:
+49(0)5246/963-9157 [email protected]
Beckhoff Service
The Beckhoff service center supports you in all matters of after-sales service:
• on-site service
• repair service
• spare parts service
• hotline service
Hotline: +49(0)5246/963-460
Fax: e-mail:
+49(0)5246/963-479 [email protected]
Quote the project number If servicing is required, please quote the project number of your product.
30 CP72xx
Appendix
CP72xx
Appendix
Assembly dimensions
The illustrations show the measurements of the Panel-PCs. Please refer to the tables for the dimensions of the Control Panel. All Dimensions in mm.
Mounting arm installation from top, rotatable
CP72xx 31
Appendix
CP72xx Mounting arm installation from bottom, rotatable
32 CP72xx
CP72xx Mounting arm installation from top, rotatable and tiltable
Appendix
CP72xx 33
Appendix
CP72xx Mounting arm installation from bottom, rotatable and tiltable
34 CP72xx
Display only without touch screen
Dimensions and total weight
with touch screen
With function keys without touch screen
Numeric keyboard without touch screen
Alphanumeric keyboard with touch screen with touch screen with touch pad without touch screen with touch screen with touch pad
Dimensions
CP7221-0000
CP7222-0000
CP7223-0000
Dimensions
CP7221-0001
CP7222-0001
CP7223-0001
Dimensions
CP7221-0002
CP7222-0002
CP7223-0002
Dimensions
CP7231-0000
CP7232-0000
CP7233-0000
Dimensions
CP7231-0001
CP7232-0001
CP7233-0001
Dimensions
CP7231-0002
CP7232-0002
CP7233-0002
Dimensions
CP7201-0000
CP7202-0000
CP7203-0000
CP7204-00xx
Dimensions
CP7201-0001
CP7202-0001
CP7203-0001
CP7204-00x1
Dimensions
CP7211-0000
CP7212-0000
CP7213-0000
Dimensions
CP7211-0001
CP7212-0001
CP7213-0001 a
12“ Display 353.8
15“ Display 426
19“ Display 504
24“ Display 610 a
12“ Display 353.8
15“ Display 426
19“ Display 504
24“ Display 610 a
12“ Display 353.8
15“ Display 426
19“ Display 504 a
12“ Display 353.8
15“ Display 426
19“ Display 504 a
12“ Display 406
15“ Display 515
19“ Display 563 a
12“ Display 406
15“ Display 515
19“ Display 563 a
12“ Display 406
15“ Display 515
19“ Display 563 a
12“ Display 426
15“ Display 483
19“ Display 504 a
12“ Display 426
15“ Display 483
19“ Display 504 a
12“ Display 426
15“ Display 483
19“ Display 504 b
370.2
410.2
535 b
370.2
410.2
535
B
370.2
410.2
535 b
308.3
370.2
426 b
308.3
370.2
426 b
308.3
370.2
426 b
326.3
395
455 b
326.3
395
455 b
326.3
395
455
450 b
326.3
395
455
450 t
27.5
28.5
45 t
27.5
28.5
45 t
27.5
28.5
45 t
27.5
28.5
45 t
27.5
28.5
45 t
27.5
28.5
45 t
27.5
28.5
45 t
27.5
28.5
45 t
27.5
28.5
45
64 t
27.5
28.5
45
64
Appendix
Weight
10.6 kg
12.3 kg
17.8 kg
Weight
10.7 kg
12.5 kg
17.6 kg
Weight
10.8 kg
12.3 kg
17.7 kg
Weight
9.9 kg
12.0 kg
16.6 kg
Weight
10.0 kg
12.3 kg
16.5 kg
Weight
10.2 kg
12.0 kg
16.6 kg
Weight
9.7 kg
11.4 kg
16.3 kg
16,0 kg
Weight
9.7 kg
11.6 kg
16.1 kg
16,0 kg
Weight
9.7 kg
11.4 kg
16.3 kg
Weight
9.7 kg
11.6 kg
16.1 kg
CP72xx 35
Appendix
Appendix
Technical data
Dimensions and weight See section Assembly dimensions
Do not use the PC in areas of explosive hazard
The Industrial PC may not be used in areas of explosive hazard.
The following conditions must be observed during operation:
Environmental conditions Ambient temperature:
Atmospheric humidity:
0 to 45°C
Maximum 95%, non-condensing
Shock resistance Sinusoidal vibration:
(EN 60068-2-6) 10 to 58 Hz: 0.035 mm
58 to 500 Hz: 0.5 G (~ 5 m/ s
During reading of CD-ROM: 10 to 58 Hz: 0.019 mm
2 )
58 to 500 Hz: 0.25 G (~ 2.5 m/ s 2 )
Impact:
(EN 60068-2-27) 5 G (~ 50 m/ s²), duration: 30 ms
During reading of CD-ROM: 5 G (~ 50 m/ s²), duration: 11 ms
Protection class: IP65 Protection class
Power supply
24 V
DC
power pack
Supply voltage:
Power consumption:
24 V
DC
(22 – 30 V
DC
) approx. 55 W for the basic version, approx. 69 W with 12“ display approx. 80 W with 15“ display approx. 87 W with 19“ display approx. 160 W with 24“ display
EMC compatibility
If operated with USV: additional 30 W (while charging)
Resistance to interference: conforms to EN 61000-6-2
Transport and storage
Emission of interference: conforms to EN 61000-6-4
The same values for atmospheric humidity and shock resistance are to be observed during transport and storage as in operation. Suitable packaging of the Industrial PC can improve the resistance to impact during transport.
The ambient temperature during storage and transport must be between
-20°C and +65°C.
Pixel errors
Note
Pixel errors in the TFT display are production-caused and represent no complaint-reason!
Approvals
FCC: Federal Communications Commission
Radio Frequency Interference Statement
FCC Approval for USA This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
FCC: Canadian Notice
FCC Approval for Canada This equipment does not exceed the Class A limits for radiated emissions as described in the Radio Interference Regulations of the Canadian
Department of Communications.
36 CP72xx
Prenesi
Oglas