BEA EAGLE ARTEK User Guide
BEA EAGLE ARTEK is a microwave sensor designed for automatic door activation. It offers one- or two-way detection modes, allowing for precise control of door operation. With adjustable detection range and sensitivity, it can be tailored to specific requirements. Installation is straightforward, with wall, ceiling, or door axis mounting options. Additionally, the sensor features remote control capability and can be configured with an access code for added security. Its compact design and IP54 rating make it suitable for various indoor and outdoor applications.
Advertisement
Advertisement
DESCRIPTION
EAGLE ARTEK
UNIDIRECTIONAL OPENING SENSOR
FOR AUTOMATIC DOORS*
User’s Guide for software version SW 0100 and higher
(refer to tracking label on product)
3
4
1
2
5
1. main connector
2. antenna
3. LEDs
4. push buttons
5. cover
TECHNICAL SPECIFICATIONS
Technology:
Transmitter frequency:
Transmitter radiated power:
Transmitter power density:
Detection mode:
Max. detection range:
Min. detection speed:
Supply voltage:
AC supply frequency:
Max power consumption:
Output:
Max. switching voltage:
Max. switching current:
Mounting height:
Degree of protection:
Temperature range:
Dimensions:
Tilt angles:
Material:
Weight:
Cable length:
Microwave
24.125 GHz
< 20 dBm EIRP
< 5 mW/cm²
Motion
Wide : 4 m × 2m | Narrow : 2 m × 2.2 m @2.2 m high
5 cm/s
12V to 24V AC +/- 10% ; 12V to 24V DC +30% / -10%**
50 to 60 Hz
< 1 W
Solid-state relay (free of polarity)
42V AC peak voltage/ 42V DC
100mA (resistive)
From 1.8 m to 4 m
IP54
From -20 °C to + 55 °C
120 mm (L) × 50 mm (H) × 50 mm (W)
0° to 90° vertical; -30° to +30° lateral
ABS
120 g
2.5 m
Specifications are subject to changes without prior notice.
Measured in specific conditions.
* Other use of the device outside of the permitted purpose can not be guaranteed by the manufacturer.
** The Equipment must be powered by an approved Class II SELV limited power source. This requirement consists of the need for double insulation between primary voltages and the Equipment supply. The supply current should be limited to max 3A.
1
1
OPENING THE SENSOR
Insert the screwdriver on the left or the right notch of the sensor and twist it to remove the cover.
2
MOUNTING & WIRING
Avoid vibrations.
Do not cover the sensor.
Avoid proximity to neon lamps or moving objects.
1
Mounting on door axis (swing doors).
2
Wall mounting above sliding or revolving door.
3
1
2
Ceiling mounting in front of door
(sliding, revolving or swing doors).
4
POWER
POWER
OPENING
OPENING
2
Apply the mounting template. Drill 1 hole
(Ø 5 - 7 mm Ø 1/4’’) for the cable and pull it through.
Drill 2 holes (Ø 3 mm Ø
1/8’’) for the screws.
3
Plug the connector accordingly.
FIELD ANGLE ADJUSTMENTS
1
2.2 m
First, position the cable according to the hole in the wall. To avoid crushing it, you can use the dedicated cable path. Next, fix the sensor firmly.
Connect to the door controller:
1 - RED - POWER SUPPLY
2 - BLACK - POWER SUPPLY
3 - YELLOW - OPENING
4 - YELLOW - OPENING.
2
2.2 m
Adjust the lateral antenna angle.
15°
30°
45°
Adjust the vertical antenna angle.
4
SETTINGS
FIELD SIZE
FIELD SHAPE
ENTER long push (2sec)
IMMUNITY
ENTER long push (2sec)
... S, XS ,
XXS ...
L
,
XL
,
XXL wide or narrow
2.2m
2.2m
OK
X 1 or increase or decrease
OK
X 1
EXIT long push (2sec)
EXIT long push (2sec)
FIELD SIZE
FIELD SHAPE
MOUNTING
HEIGHT
IMMUNITY
FILTER
DETECTION
MODE
OUTPUT
CONFIG.
HOLD-OPEN
TIME
DOOR
CONTROL
RESETTING TO
FACTORY VALUES
XXS XS S > > > > L XL XXL narrow wide low normal high bi
NO uni
NC
> > > > > highest uni
PRM uni
AWAY
PRM &
AWAY bi = two-way detection; uni = one-way detection towards sensor; uni PRM = one-way detection also of people with reduced mobility; uni AWAY = one-way detection away from sensor.
0.5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s auto open closed open = the sensor detects constantly. The LED is ON.
closed = the sensor is in standby and does not detect. The LED is OFF.
FACTORY VALUES:
The access code (1 to 4 digits) is recommended to set sensors installed close to each other.
SAVING AN ACCESS CODE:
DELETING AN ACCESS CODE:
Once you have saved an access code, you always need to enter this code to unlock the sensor. If you forget the access code, cut and restore the power supply . During 1 minute, you can access the sensor without introducing any access code.
3
SERVICE MODE
> 4 sec
.
The service mode deactivates the detection during 15 minutes and can be useful during an installation, a mechanical teach-in of the door or maintenance work.
To enter the service mode, push on the button for at least 4 seconds . When the sensor is in service mode, the LEDs are off.
To exit the service mode, push any button.
RESETTING TO FACTORY VALUES:
> 4 seconds
+
OR
TROUBLESHOOTING
The door remains closed.
The LED is OFF.
The sensor power is off.
1 Check the wiring and the power supply.
The door does not react as expected.
The door control setting (F2) is set to value 3 (closed).
Improper output configuration on the sensor.
1
1
Change the door control setting (F2) to value 1
(automatic).
Change the output configuration setting on each sensor connected to the door operator.
4
The door does not react as expected.
The door opens and closes constantly.
The door opens for no apparent reason.
The wire to the antenna is disconnected or damaged.
The sensor is disturbed by the door motion or vibrations caused by the door motion.
1 Check if the wire to the antenna is crushed or cut.
2
1
2
3
4
5
Replace sensor.
Make sure the sensor is fixed properly.
Make sure the detection mode is unidirectional.
Increase the antenna angle.
Increase the immunity filter.
Reduce the field size.
1
2
Make sure the detection mode is unidirectional.
Increase the immunity filter.
It rains and the sensor detects the motion of the rain drops.
In highly reflective environments, the sensor detects objects outside of its detection field.
1
2
3
Change the antenna angle.
Decrease the field size.
Increase the immunity filter.
The LED flashes quickly after unlocking.
In airlock vestibules, the sensor detects the movement of the opposite door.
The sensor needs an access code to unlock.
1
2
3
Change the antenna angle.
Adjust the field shape.
Increase the immunity filter.
1
2
Enter the right access code.
If you forgot the code, cut and restore the power supply to access the sensor without access code.
Change or delete the access code.
1 Check and change the batteries if necessary.
The sensor does not respond to the remote control.
Batteries in the remote control are weak or installed improperly.
Remote control badly pointed.
1 Point the remote control towards the sensor.
BEA SA | LIEGE Science Park | Allée des Noisetiers, 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | [email protected] | www.beasensors.com
BEA hereby declares that the Eagle Artek is in compliance with European Directives 2014/53/EU (RED) and
2011/65/EU (RoHS). The full text of the EU declaration of conformity is available on our website.
This product should be disposed of separately from unsorted municipal waste