Chamberlain LiftMaster CB202EV Instruction
Chamberlain LiftMaster CB202EV is a sliding gate operator designed for residential use, offering reliable and secure control over your gate. It features adjustable force and speed settings, allowing you to customize its operation to your specific needs. The built-in timer-to-close (auto-close) function adds convenience, automatically closing the gate after a set time. The control board comes with an easy-to-read LED display for programming and troubleshooting. Safety features like entrapment protection devices and a reversing mechanism ensure safe operation.
Pubblicità
Pubblicità
Instruction CB202EV
®
TOPIC PAGE
SAFETY RULES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
TYPICAL CONFIGURATION OF A UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
INSTALLATION OF CONTROL BOARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
WIRING OF CONTROL BOARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
WIRING DIAGRAMM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
TECHNICAL DATA OF CONTROL BOARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
DESCRIPTION OF TERMINALS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
DESCRIPTION OF LEDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
DESCRIPTION OF PUSH BUTTONS P1, P2, P3 & RESET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
RADIO TRANSMITTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
FLASHING LAMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
KEYSWITCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
STOP SWITCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
SAFETY EDGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
CONTACT EDGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
SAFETY ACCESSORY KIT /myQ / DOOR MONITOR.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
PHOTOCELLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
RADIO AND RADIO PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
PROGRAM INTERNET GATEWAY / DOOR MONITOR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
LOOP DETECTOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
DIP SWITCH SETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
INITIAL OPERATION / BASIC SETTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-12
TIMER TO CLOSE (AUTO-CLOSE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
FORCE / TORQUE OF MOTOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
DISPOSAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
BATTERY DISPOSAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
DIAGNOSIS LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
FAQ’S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
WARNING / ATTENTION
IMPORTANT FITTING AND OPERATING INSTRUCTIONS
PLEASE START BY READING THESE IMPORTANT SAFETY RULES
This safety alert symbol means „Caution“ - failure to comply with such an instruction involves risk of personal injury or damage to property. Please read these warnings carefully.
This gate drive mechanism is designed and tested to offer appropriately safe service provided it is installed and operated in strict accordance with the following safety rules.
Incorrect installation and/or failure to comply with the following instructions may result in serious personal injury or property damage.
When using tools and small parts to install or carry out repair work on a gate exercise caution and do not wear rings, watches or loose clothing.
Installation and wiring must be in compliance with your local building and electrical installation codes. Power cables must only be connected to a properly earthed supply.
Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate. Locate entrapment protection devices to protect in BOTH the open and close gate cycles. Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts.
Please remove any locks fi tted to the gate in order to prevent damage to the gate.
After the installation a fi nal test of the full function of the system and the full function of the safety devices must be done.
This drive cannot be used with a gate incorporating a wicket door unless the drive cannot be operated with the wicket door open.
Frequently examine the installation for imbalance and signs of wear or damage to cables, hardware and mountings. Do not use if repair or adjustment is necessary. Gates which stick or jam must be repaired immediately. Employ a qualifi ed technician to repair the gate, never attempt to repair it yourself.
Keep additional accessories away from children.
Do not allow children to play with pushbuttons or remote controls. A gate can cause serious injuries as it closes.
Disconnect electric power to the system before making repairs or removing covers.
A disconnecting device must be provided in the permanently-wired installation to guarantee allpole disconnection by means of a switch
(at least 3mm contact gap) or by a separate fuse.
Make sure that people who install, maintain or operate the gate drive and/or the control board are qualifi ed and follow these instructions.
Keep these instructions in a safe place so that you can refer to them quickly when you need to.
The full protection against potential squeeze or entrapment must work direct when the drive arms are installed.
Gate must not extend over public byway during operation.
Lightweight gates must be substantially reinforced to avoid gate damage. The best solution is to check with your gate manufacturer for an opener installation reinforcement kit.
Activate opener only when the gate is in full view, free of obstructions.
Do not allow children to play near the gate.
Humidity and water destroy the control board.
Make sure under all circumstances that water, humidity or dammed-up water cannot penetrate the control board covering.
This appliance is not intended for use by persons (including children) with reduced physical sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Automatic drive – Keep away from the area of the gate since it may operate unexpectedly.
SAVE THESE INSTRUCTIONS
1/14 en
TYPICAL CONFIGURATION OF A UNIT
1. Drive with control board
The drive is located on a height-adjustable
mounting plate.
2. Photocell min. 150- max200 mm (optional)
First photocell.
Detects low objects.
3. Photocell max. 700 mm (optional)
Second photocell.
Detects vehicles and higher objects.
4. Flashing light (optional)
Important visual information indicating gate
movement.
5. Safety edge (optional)
Detects obstacles and avoids risks
produced by gate movement.
Safety edges can be mounted on the gate
or on the pillars. If the gate has openings
exceeding 45mm, a safety edge is
required on the pillar (accessory).
If required, safety edges must be mounted
at a height of up to 2.5m.
3
2
4
5
INSTALLATION OF CONTROL BOARD
The CB202EV control board was designed for installation in a special covering under the housing of the sliding gate drive.
The installation of the control board is allowed only after the completion of the mechanical installation. All work on the control board must be performed after disconnecting it from the mains.
Turn on the power only when it is prompted in the section INITIAL
OPERATION/BASIC SETTING.
To operate, at least the following connections have to be established: -
- “Power supply”
- Transformer “Input & Transf”
- Motor “MOTOR”
- Plug limit switch “LIMIT SWITCH”
- Plug „RPM/ENCODER“
If necessary assemble the following optional connections:
- photocells
- safety edge
- fl ashing light
- external antenna
- key switch or other external control devices
1
3
2
2/14 en
WIRING OF CONTROL BOARD
The cables for the power supply and the connected equipment are routed from below into the sliding door operator through the rubber seal at the bottom of the control board covering.
The control board is to be mounted with the terminal strips down as shown in the picture A.
Generally avoid:
- 230Volt and low voltage in the same power line. Not allowed by
electrical rules.
- Wiring of the photocells, switches, fl ashing lamps require a cable
separately from the motor wiring.
- Other wirings like telephone intercoms, lights for garden etc. must
be in separate cables.
- Rigid copper cables especially when thicker diameters are diffi cult
to manage during the installation and may result in bad
connections with functional issues. Use fl exible cables instead.
- Cable material not suitable for outside use. Use cables suitable for
outside use and underground. Run the cables in conduits if the
cable is not suitable for placing in the ground (armoured or suitably
protected). You may also consult your local electrician.
Terminals:
The terminal blocks on the controller can be removed (pull) to facilitate a convenient wiring and are pushed back only while installing the controller. Even if a terminal strip is not in use, it must be pushed back. The wiring is done as described in the wiring diagram.
Plugs (available on the motor and the transformer):
These plugs must be connected to the control board (plugged in).
The cable of the connectors are not routed from below, but from the back of the control board (see picture B).
1. 230 Volt transformer feeder TRANSF IN and INPUT 24 VAC
2. Limit switch
3. Motor connector RPM/Encoder
Motor wiring: connect to designated terminals as per wiring diagram
See page 5 for description of terminals pic. A pic. B
3
Wire sizes: see chart
Switches, Flashing lamp
etc.
Photocells, safety edge
Power supply
Distance
0m - 10m
2x 0,5mm²
2x 0,5mm²
3x 0,72mm²
Distance
10m - 12m
2x 0,75mm²
2x 0,75mm²
3x 1,5mm²
Note:
The terminals are designed for a max. cable diameter of 1,5mm² (fl exible wire).
Distance
12m – xx
Min. 2x 0,75mm²
Max. 30m
Min. 2x 0,75mm²
Max. 20m
3x 1,5mm²
1
2
3/14 en
WIRING DIAGRAM
50 Ohms
L PE N
230V~
+/- 10%
50Hz
PHO1 close/schliessen/fermer/sluiten
8.2
Ω
+ +
PHO2
+ + close/schliessen/fermer/sluiten
+ + open/öffnen/ouvrir/open
TECHNICAL DATA OF CONTROL BOARD
Voltage:
Transformer:
Output Motor:
Consumption max.:
Consumption Standby:
Operating temperature:
230 V~ / 50-60 Hz ±10%
230 V / 24 V, 105 VA
24 VDC max. 400 W (in operation) max. 4 W (without accessories)
-20º C ÷ 55º C
Measurements:
Protection class Box:
Fuse:
Remote control: usable frequencies:
145 x 110 mm (without box)
IP45
2 x 2 A (fast-blow fuse) max. 170 x Rolling Code
433 MHz, 868 MHz
The control board is a highly modern electronic unit controlled by a microprocessor. It has all wiring facilities and functions required for safe operation. The electronics provides an ideal and matching closing force. When installed and adjusted correctly the gate can be stopped manually. During operation, the gate can be stopped via remote control, push-button or key-switch. The gate requires a fi rm stop for “OPEN” and “CLOSED” position.
Humidity and water destroy the control board. Make sure under all circumstances that water, humidity or dammed-up water cannot penetrate the control board covering. All openings and cable entries must be sealed watertight.
4/14 en
DESCRIPTION OF TERMINALS
Description Function
120 -230 VAC
50 - 60 Hz
POWER SUPPLY connector
TRANSF IN
INPUT 24 V
30 VDC
Motor
Motor
24 V / 150 mA
Key symbol
COM
PHOTO2
PHOTO1
COM
STOP
8.2 kOhms
RPM / ENCODER
LIMIT SWITCH
2 A
230 V to transformer
24 V from transformer output 30 VDC or terminal for external battery blue cable red cable fl ashing light (accessory) keyswitch, other control devices negative pole photocells 2 (accessory) photocells 1 (accessory negative pole stop switch or safety edge with 8.2 KOhms (accy) socket for rpm-sensor socket for limit switch
2x fast-blow fuse included 250V/2A
DESCRIPTION OF LEDS (LIGHT EMITTING DIODE)
DESCRIPTION COLOUR STATUS
STOP / 8.2 kOhms green Stop Switch wire no
“Key symbol” red Key-switch
PHO 1 red Photocell 1 (close)
OK, connected
or detected
PHO 2 red Photocell 2 (adjustable)
OK, connected
or detected
OPEN LIM
CLOSE LIM
yellow
yellow limit switch GATE OPEN limit switch GATE CLOSED
DGN red Diagnostic, also refer to page 13
LEARN yellow Programming indicator
active
CH1 red Remote control programming for
programmed
CH2 red Remote control programming for opening CH1)
DESCRIPTION OF PUSH BUTTONS P1, P2, P3 & RESET
Button
P1+P2+P3
P1
Function
Limit setting: Push P1+P2+P3 simultaneously. The LED LEARN starts to fl ash as long as feature is activated.
Button P1 operates Motor. Deactivate: Wait for 20 seconds or disconnect logic board from power.
P1
P1 + P2
P2 ; P3
P3
Force / travel distance - setting “BASIC”; from position CLOSE LIM
Force / travel distance - setting “ADVANCED”; from position CLOSE LIM; with option Soft-Stop setting
Timer to close. Factory setting: off. See page 12 for details.
Software-reset to factory defaults. Push & hold for 10 seconds. Does not reset memory (see section “radio”).
DIP „RADIO
PROGRAM“ + P1
Program Remote for Channel 1 Command for OPEN completely
DIP „RADIO
PROGRAM“ + P2
Program Remote for Channel 2 Command for OPEN partially
RESET Program Internet Gateway or Door Monitor Note: The RESET button does not perform a reset of this particular control board
to factory defaults . It is only meant to program the Internet Gateway and the Door Monitor. See function P3 for resetting the
board to factory default settings.
5/14 en
ACCESSORIES (also refer to wiring diagram)
RADIO TRANSMITTERS (OPTIONAL) MODELS:
TX2EV, TX4EV, TX4UNI (remote controls), 747EV (wireless keypad), 128EV (2-channel wall control)
FLASHING LAMP (OPTIONAL) MODEL: FLA24-2, FLA1-LED
A fl ashing lamp can be connected to the control board (Terminals: 24 V / 150 mA). It indicates gate movement. The fl ashing light should be
mounted as high as possible and in good clear view. The control board emits a constant signal that the lamp converts to a fl ashing signal.
KEY SWITCH (OPTIONAL) MODEL: 100010, 100027, 100034, 100041
The system can be operated by key switch (Terminals: key symbol and COM). Also see OPEN/PED under “DIP SWITCH SETTINGS”.
STOP SWITCH (OPTIONAL) MODEL: 600084
A stop switch to stop the movement of the gate in any direction can be connected to this output (Terminals: Stop / 8,2 kOhm).
Also see STOP/8.2kOHM under “DIP SWITCH SETTINGS”.
SAFETY EDGE (OPTIONAL) MODEL: 600046, 600053, 600077, 600060
(DIP must be off)
A safety edge working according to the 8.2 kilo ohm principle can be connected to the control board (Terminals: Stop / 8,2 kOhm), i.e. a 8.2 kilo
ohm test resistor is attached to the end of the safety edge. It ensures that the electric circuit is monitored permanently. The control board is
supplied with an 8.2 kilo ohm resistor installed. Several safety
PHOTOCELLS (OPTIONAL) MODELS: 771E, 772E
The use of photocells is recommended. Use either model 771E or 772E which is also part of Safety Accessoy Kit APLUS-EV
SAFETY ACCESSORY KIT (OPTIONAL): APLUS-EV
The control board is already supplied with an antenna as standard. For special operating distances, an external antenna from the APLUS-EV
accessory kit (includes Photocell 772E, Flashing Light FLA1-LED, and External Antenna SWG-ANT-EV) can be connected as shown in the
wiring diagram.
myQ (OPTIONAL)
(only with 828EV Internet Gateway):
Allows operating the gate opener via Internet or compatible smartphnone.
Door Monitor (OPTIONAL)
(only with 829EV door monitor):
allows optical and acoustical monitoring of the gate position. The gate can also be closed with the device.
For appropriate cable diameters see chart on page 3.
6/14 en
PHOTOCELLS (OPTIONAL) MODEL: 771E / 772E
The photocells are for safeguarding the gate and must be used.
The fi tting location depends on the gate’s design. EN12453 specifi es that a pair of photocells must be installed outside at a height of 200 mm and activated to “Close”. The photocells consist of a transmitter and a receiver and must be opposite each other. The photocell is mounted on the wall using small screws and wall plugs.
Programming of IR sensors:
- connect IR sensors
- program the travel of the gate
Deletion of IR sensors:
Disconnecting already connected IR sensors will cause the control board to block the functionality of the terminals it was connected to.
To delete IR sensors correctly:
- switch off control board
- disconnect IR sensors
- switch on control board
- program travel distance
Diagnosis of the photocell
LED on = OK
LED fl ashes = photocell disables control board
LED off = no current, incorrect connection or polarity
Diagnosis on the control board LED PHO1 / PHO2
LED constant = OK
LED off = A (no photocell connected)
B (photocell interrupted and diagnostic LED is fl ashing.
See page 13)
Connection between 1 & COM:
Active when gate is closing (reverses gate to open)
Connection between 2 & COM: adjustable:
DIP “PHO 2 MODE” is off >> active when gate is closing
DIP “PHO 2 MODE” is on >> active when gate is opening
RADIO AND RADIO PROGRAMMING
PROGRAM / DELETE REMOTE CONTROLS
The receiver has two channels CH1 and CH2.
The respective LEDs CH1 and CH2 are assigned to these two channels. Receiving a signal from a programmed remote control button, CH1 fully opens the gate.
Receiving a signal from another programmed remote control button, CH2 partially opens the gate (pedestrian mode).
PROGRAMMING
1. Switch on DIP “RADIO PROGRAM”
2. Briefl y push button P1 (for CH1) or P2 (for CH2) and the
respective LED lights up.
3. Press and hold a selected button on your remote control until
LED goes out after 5 times fl ashing. Done!
Repeat for all remote controls (a maximum of 85 remote
controls can be programmed to each channel).
Important: To fi nish programming, Switch off DIP “RADIO PROGRAM”!
Note: Make sure not to program the same remote control button to
CH1 and CH2, otherwise the gate will work improperly.
DELETE
- Switch on DIP “RADIO PROGRAM”.
- Press and hold learn-button P1 for approx. 10 seconds
until LED goes out again. All codes programmed are deleted.
To confi rm both LEDs CH1 and CH2 fl ash 8 times.
- Switch off DIP “RADIO PROGRAM”.
PHO1 close/schliessen/fermer/sluiten
8.2
Ω
+ +
PHO2
+ + close/schliessen/fermer/sluiten open/öffnen/ouvrir/open
+ +
7/14 en
PROGRAM INTERNET GATEWAY myQ
Using the RESET -Button on the control board
1. Connect the ethernet cable to the LiftMaster Internet Gateway
and the router.
2. Connect power to the LiftMaster Internet Gateway.
3. Create an online account on the latest Liftmaster MyQ smartphone
application or on www.liftmaster.eu. It is recommended to use the
smartphone as it will allow you to stand close to the gate while programming
4. Register the LiftMaster Internet Gateway.
5. Click on „Add new device“ and follow the steps given by the
application or on the webpage.
6. Note: When pushing the RESET-Button you will hear a beep and the
LEDs CH1 and CH2 fi rst go on, then after matching, the LEDs will
blink 3 times and go out.
7. The App will tell you if programming was successful and will prompt
you to assign a name to the gate.
PROGRAM DOOR MONITOR
Using the RESET -Button on the control board
1. Connect power to the door monitor.
Position the door monitor in a convenient visible place inside the house.
If this place is too far from the gate opener the connection may not be
possible or is often interrupted.
Choose a more convenient place.
2. Press and release the „LEARN“ button on the back of the door monitor.
Red and green LED blink alternately.
Within 60 seconds press and release the RESET button on the control board.
To confi rm programming red and green LED on the door monitor are on.
DELETE DOOR MONITOR
Press the „LEARN“ button on the back of the door monitor for at least 10 sec.
A short „beep“ confi rms that deleting was successful.
8/14 en
LOOP DETECTOR (OPTIONAL)
DIP “OPEN/PED” must be on.
Loop detectors react to metal and the most common use is for cars or trucks but not for bikes or pedestrians.
Exit loop / Gate Opening Loop
An exit loop is behind the gate and opens the gate when closed, keeps it open or re-opens the gate.
The DIP “OPEN/PED” must be on.
The gate requires installed photocells and timer to close activated.
In addition, the feature “Fast closing” can be activated.
Refer to section “Description of Push Buttons P1, P2, P3 & RESET”.
DIP SWITCH SETTINGS
RADIO PROGRAM
The DIP “RADIO PROGRAM” is required to program remote controls.
For programming procedure please refer to the respective section in this manual.
OFF: No programming of remote controls possible
ON: Programming of remote controls possible
Important: Always switch off DIP “RADIO” after use!
STOP/8,2 KOhm
Defi nes whether the terminal STOP/8,2KOhm is used in emergency stop mode or safety edge mode. With an emergency stop any movement of the gate will be stopped. When used for a safety edge the gate reverses for aproximately 20 cm.
OFF: Factory setting is 8,2KOhm. Safety edge or 8.2kOhm resistor is required.
ON: Emergency stop required. In this case the resistor must be removed and replaced by the switch or a switch circuit.
OPEN/PED
Defi nes if a key switch opens the gate completely or partially.
Note: If the DIP “OPEN/PED” is on and timer to close is activated as well, the functionality of the terminals “key symbol” and “COM” changes. See section “Loop Detector” above.
OFF: opens partially (ca. 100 -150 cm)
ON: opens completely
PHO 2 MODE
Defi nes whether the second photocell is active in closing or in opening.
OFF: active in closing
ON: active in opening
WIRE JUMPER (DIP FIX):
OBSTACLE
Factory-equipped with wire jumper. Disabling (opening) increases the operating power at the control.
CAUTION: If the jumper is disabled, the door system must be secured with additional safety devices (safety edge, etc.).
SPEED
Factory-equipped with wire jumper. Disabling (opening) increases the operating speed of the gate.
CAUTION: If the jumper is disabled, the door system must be secured with additional safety devices (safety edge, etc.).
Wire jumper
NO
Model
203292
9/14 en
INITIAL OPERATION / BASIC SETTING
Proceed step by step. When in doubt, start again at the beginning. Take suffi cient time to make these settings.
1. Are all components required for operation connected? Motor, photocells, safety safety edge, stop switch.
2. Limit switches are fi xed to the rack?
3. Setting of DIPs => all off (settings can be done later)
4. Make sure nobody is present in the gate area.
Note:
When connecting the control board for the fi rst time (no basic setting has been done) the Diagnosis-LED will indicate the status of the photocell terminals and, depending on the confi guration, blink between 4 and 7 times. This indication is regular and can be ignored until Basic Setting (also see page 12 “Diagnosis-LED”).
Now connect control board to power
BASIC SETTING:
1. Move the gate manually to a position between the two
limit switches OPEN - CLOSE and engage gate opener.
2.
2. Press buttons P1, P2 and P3 at the same time for about
2-3 sec. LED „LEARN“ starts to fl ash.
3. Now watch the gate. The gate can be moved in both
directions using the button P1. Press the button P1 several
times (1-2 seconds each time) to understand the function
of the button. If none of the buttons are pressed for about
15 seconds, the control switches back to normal operation.
Repeat step 2 in this section.
4. Fully open the gate with the button P1.
Keep P1 pressed until the controller turns off by itself at
the limit switch OPEN. (Do not release before).
Control: The LED „OPEN LIM“ (yellow) = limit switch
OPEN goes on. Otherwise, change the limit switch
position before further settings are made.
2.
5. Close the gate with the button P1 till it is turned off at the
limit switch CLOSED. (Do not release beforehand).
Control: The LED „CLOSE LIM“ (yellow) = limit switch
CLOSED goes on.
Basic setting is completed. LED „LEARN“ will go out.
The full travel distance and force setting can now be programmed as described on page 11.
2.
10/14 en
PROGRAMMIING THE TRAVEL DISTANCE AND
OPERATOR FORCE
1. Gate is closed, gate position is “Close Limit”.
LED „CLOSE LIM“ glows.
2.
2. Press the button P1 until the door starts to open.
(LED „LEARN“ glows)
The automatic programme starts (slow speed).
3. The drive moves the gate to the limit switch OPEN,
stops briefl y and then moves back to the limit switch
CLOSED.
4. After reaching the limit switch CLOSED, the LED
„LEARN“ goes out. The programming of the distance and
the force required is completed.
2.
Proceed with “Radio an Radio Programming” and “Completion of
Installation”.
Alternative:
PROGRAMMING THE DISTANCE „ADVANCED“ (INDIVIDUAL)
Note: The button P1 must be pressed several times in this program. With each press of the button, the position at which the soft-stop (slow speed) starts is saved. Long or short soft-stop settings are possible.
1. Gate is closed, gate position is “Close Limit”.
LED „CLOSE LIM“ glows.
2. Press P1 and P2 simultaneously for a longer time (about
5-6 seconds) until the door opens.
Release buttons! LED “LEARN” fl ashes.
3. Press P1. Soft-stop in the OPENING direction starts from
this position.
2.
2.
4. Press P1 again when the gate moves in CLOSING
direction, soft-stop starts from this position.
2.
When LED „LEARN“ goes out, the programming is completed successfully.
Proceed with completion of Installation / programming
11/14 en
COMPLETION OF INSTALLATION / PROGRAMMING
Once the travel distances are programmed, the remote controls can be programmed as well.
(Refer to “Radio and Radio Programming”)
1. You can now let the gate run 2 complete cycles by pressing a key on the remote or a connected switch and observe the process.
Close the gate again, WITHOUT making another setting.
2. Check operation of photocells, switch, fl ashing light, remotes, accessories, etc.
3. Advise people using the gate with regard to gate operation, safety functions and how to release the gate in order to operate it manually.
TIMER TO CLOSE (AUTO-CLOSE)
NOTE: Only possible with connected photocells (PHOTO + COM).
NOTE: Using this function the OPEN travel can be started but not be stopped by a command.
Pause time from 2 seconds up to 120 seconds is adjustable.
Activate:
1. Press and hold P2 until yellow LED starts fl ashing
2. Now count the time you wish to program
3. Press P2 again. Done!
Deactivate:
1. Press and hold P2 until yellow LED starts fl ashing.
2. Press P3. Yellow LED goes out. Done!
Select Pause time mode:
A: Restart of pause time on interrupt of PHOTO (Condominium Function)
1. Press P2 + P3
2. LED „LEARN“ will fl ash once.
B: Shorten pause time to 5 sec on interrupt of PHOTO (Residential Function)
1. Press P2 + P3
2. LED „LEARN“ will fl ash 2 times.
FORCE / TORQUE OF MOTOR
Thrust of the motor is set automatically while programming the travel
distance. Thrust can only be modifi ed by programming the travel
distance again. If gate movement is impeded by weather or changes
to the installation (rust or inappropriate lubrication) it may have to be
repaired.
The control board complies with the latest EU guidelines.
One of these guidelines specifi es that the closing forces
at the gate edge must not exceed 400N (40 kg) for the last 500 mm
before the door is CLOSED. Above 500 mm, the maximum force at
the gate edge must not exceed 1400 N (140 kg). If this cannot be
ensured, a safety edge must be mounted on the gate at a height up
to 2.5 m or on the pillar on the opposite side (EN12453).
DISPOSAL
The packaging is made from environmentally friendly materials. It can be disposed of in the local recycling bin. According to the European
Directive 2002/96/EC on waste electrical and electronic equipment, this device must be properly disposed of after use to ensure the reuse of
materials. The information on the possibilities of this waste disposal is provided by the local government or municipality.
BATTERY DISPOSAL
Batteries and rechargeable batteries may not be disposed along with domestic waste, but are
obliged to be returned.
After use they can be returned free of charge locally e.g. in trade or at municipal collecting points.
Batteries and rechargeable batteries are marked with a crossed waste container as well as with the
chemical symbol which describes their toxic element, “Cd” for cadmium, “Hg” for mercury and “Pb” for lead.
12VDC
Pb Cd Hg
12/14 en
DIAGNOSIS LED
The LED diagnostics always shows the latest upcoming issue. If several issues occur the LED diagnostics does not show them.
Example: The gates’ guiding rail is soiled and the drive performs a safety reversal due to too high force. After that the photocell beam got interrupted. Diagnosis: As long as the photocell beam is interrupted the diagnosis LED fl ashes 6x respectively 7x.
Indication
1x blinking
2x blinking
3x blinking
4x blinking
Description
Motor has insuffi cient connection to control board
Remedy
Check terminals precisely. Consider wire lengths
Limit switch GATE CLOSED
Limit switch GATE OPEN
Interruption of programming / no programming
Progamming travel distance failed because the gate never reached the limit switch GATE CLOSED. Repeat programming the travel distance according to instructions
Progamming travel distance failed because the gate never reached the limit switch GATE OPEN. Repeat programming the travel distance according to instructions
The control board has never been programmed
5x blinking
6x blinking
7x blinking
8x blinking
9x blinking
10x blinking
11x blinking
12x blinking
Force very unsteady
Photocells 1 block installation
A: Obstacle interrupts beam
B: poor alignment of the lenses
C: power supply for photocells not suffi cient
Photocells 2 block installation
Emergency stop blocks installation
Safety edge blocks installation
A: Obstacle pushes safety edge
B: Safety edge defective
C: Power supply too low or wire damaged
A: Gate to heavy or rough running
B: Gate blocked / or rough running at a certain position
C: Gate not balanced
D: Faulty mechanical installation
All: consult gate dealer/specialist
A: remove obstacle
B: check alignment
C: check terminals and wire diameter refer to 6x blinking
A: check wires and wiring
B: check basic setting of control board (DIPs)
A: remove obstacle
B: check wires, wiring and 8.2kOhm resistor
C: check basic setting of control board (DIPs)
Power supply to control board too low
A: 230V supply defective or faulty connection
B: damaged wire in powercable
C: Back up battery (optional accessory) empty
EEPROM Fault
Power up failed
A: check terminals/connections
B: consult dealer/specialist
C: charge battery min. 24h
Replace contol board
Defect on relay or major electrical component
A: Overload
B: Bad wiring (wrong)
C: water in photocells (bad installation)
D: a photocell was connected before but not removed
(disconnected)
Replace logic board
Check wiring
Reprogram the travel distance from gate fully closed
13/14 en
FAQs
Pressing P1, P2 and P3 does not show any reaction
The gate opener doesn’t respond at all; no LED is on.
Possibly power failure.
DIP “RADIO PROGRAM” must be off
1. Check conductor and zero conductor.
2. Check house fusing.
“
Immediately after the gate has started moving, it stops and reverses.
Gate can only be opened
Timer to close” doesn’t work.
The control board does not work any more using the transmitter, only with the switch and even then only as long as a button is pressed and kept pressed.
The gate opener doesn’t respond at all, although the controller has been connected (LEDs are on).
Obstacle in area of gate.
Gate rough running (consult dealer) photocell blocks
Check gate area for objects check photocells reprogram travel distance
Function and connection must be checked
Photocell, a safety edge or the emergency stop disables the control board
Only one photocell was connected for OPEN
Only works if the 2-cable photocell 771E(ML) or 772E(ML) installed.
At least 1 pair of photocells active in
OPEN or CLOSED must be connected
Control board does not work with transmitter
Control board does not work
Gate doesn’t open completely
Travel distance can’t be programmed
1. Remote control not programmed.
2. LEDs indicate a fault.
3. Photocell connected incorrectly.
4. Motor terminal possibly not connected properly.
1. transmitter not programmed
2. photocells block
3. DIP “RADIO PROGRAM” is on travel distance not programmed
1. Programming remote control.
2. Find and rectify fault(s) (see description of diagnostic LEDs).
3. Check photocell connection / programming.
4. Check terminals and connections.
1.Program transmitter
2.Check photocells, check diagnostic LEDs
3. DIP “RADIO PROGRAM” must be off.
Program travel distance. See initial operation / diagnosis LED
Gate heavy / rough running re-program travel distance consult dealer/specialist
1. DIP setting not correct
2. see Diagnostic LED
3. interferences in wiring of photocells, switch or safety edge
4. Gate moves for 1 second only and stops without reversal during programming
5. Magnetic limit switch
1: follow the instruction of “Initial Operation” closely
3: remove for checking, then re-program travel distance
4: check RPM sensor/Encoder on control board
5: install magnetic limit switch properly
The operator sometimes movess slowly Powerfailure
Limit switches OPEN and CLOSED nicht correctly indicated
Gate opens instead of closing automatically
(Timer to close activated) incorrect programming incorrect programming
Common procedure. After powerfailure the operator performs a selftest. Depending on the operator model this can take a few seconds or a complete cycle. Do not interrupt this test via remote control or switch, otherwise the limits may change. If this is the case reprogram travel distance using P1.
During programming the limit switch OPEN must be reached using P1, then limit switch
CLOSED. Switching motor cables is not required.
repeat programming as described in these instructions
The remote control’s range is too short.
The gate must follow a slope.
The installation of an external antenna is recommended as the controller with the short cable antenna is located either behind the post or near ground level in most cases. The optimum location of the antenna is as high as possible in all cases. An appropriate antenna with installation kit can be obtained as an accessory.
Not recommended! Change gate! The gate can move in an uncontrolled (dangerous) manner if the gate opener has been released. A stronger force is needed in the upwards direction of the slope and then, in the opposite direction, the gate opener’s force is too strong.
14/14 en
EG-Einbauerklärung
Chamberlain GmbH erklärt, dass die nachfolgend bezeichneten Produkte der Typen:
Schiebetorsteuerung, Modell CB202EV den grundlegenden Anforderungen der nachfolgenden EG-Richtlinien entsprechen, wenn sie bestimmungsgemäss nach Anweisungen des Herstellers verwendet werden.
EG-Maschinenrichtlinie 2006/42/EG
Die unvollständige Maschine entspricht weiterhin allen Bestimmungen der EG- Bauprodukte-Richtlinie (89/106/EWG), der EG-Elektromagnetische Verträglichkeit-Richtlinie(2004/108/EG und der EG-Niederspannungs-Richtlinie
(2006/95/EG).
Insbesondere wurden folgende harmonisierte Normen angewandt:
DIN EN 12453 Nutzungssicherheit kraftbetätigter Tore - Anforderungen
DIN EN 12604 Tore - mechanische Aspekte - Anforderungen
EN 61000-6-3 Elektromagnetische Verträglichkeit (EMV) - Teil 6 - 3:
Fachgrundnormen - Störaussendung - Wohnbereich, Geschäfts- und
EN 60335-1 Sicherheit elektrischer Geräte für den Hausgebrauch und ähnliche Zwecke
EN 60335-2-103 Besondere Anforderungen für Antriebefür Tore, Türen und Fenster
Alle technischen Daten für diese Produkte werden sicher aufbewahrt und durch Chamberlain GmbH auf Anfrage den
Behörden, falls erforderlich, zur Verfügung gestellt.
Christoph Marny
Manager, Regulatory Affairs
Chamberlain GmbH
Alfred-Nobel-Strasse 4
D-66793 Saarwellingen
September 2014
114A4744
Chamberlain GmbH
Alfred-Nobel-Strasse 4
66793 Saarwellingen
Germany www.liftmaster.eu
© 2014, Chamberlain GmbH
Scarica
Pubblicità