Yaskawa STF Sigma Trac Manual
विज्ञापन
विज्ञापन
AC Servo Drives
-
V
Series
USER’S MANUAL
Design and Maintenance
Linear Motor
MECHATROLINK-
II
Communications Reference
SGDV SERVOPACK
SGLGW/SGLFW/SGLTW/SGLC/SGT Linear Servomotors
MANUAL NO. SIEP S800000 48K
Outline
Panel Display and
Operation of Digital Operator
Wiring and Connection
Operation
Adjustments
Utility Functions (Fn )
Monitor Displays (Un )
Troubleshooting
Appendix
5
6
3
4
7
1
2
8
9
Copyright © 2007 YASKAWA ELECTRIC CORPORATION
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of Yaskawa. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because Yaskawa is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, Yaskawa assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication.
About this Manual
This manual describes information required for designing, testing, adjusting, and maintaining Σ -V Series
SERVOPACKs.
Keep this manual in a location where it can be accessed for reference whenever required. Manuals outlined on the following page must also be used as required by the application.
Description of Technical Terms
The following table shows the meanings of terms used in this manual.
Cursor
Servomotor
Term
SERVOPACK
Servo Drive
Servo System
MII Model
Servo ON
Servo OFF
Base Block (BB)
Servo Lock
Main Circuit Cable
Zero-speed Stopping
Linear Scale Connection
Cables
Meaning
Input position indicated by Digital Operator
Σ -V Series SGLGW, SGLFW, SGLTW, SGLC linear servomotor or
SGT linear slider
Σ -V Series SGDV servo amplifier
A set including a servomotor and SERVOPACK (i.e., a servo amplifier)
A servo control system that includes the combination of a servo drive with a host controller and peripheral devices
MECHATROLINK-II communications reference used for SERVO-
PACK interface
Power to motor ON
Power to motor OFF
Power supply to motor is turned OFF by shutting off the base current to the power transistor in the current SERVOPACK.
A state in which the motor is stopped and is in position loop with a position reference of 0.
Cables which connect to the main circuit terminals, including main circuit power supply cables, control power supply cables, servomotor main circuit cables, and others.
Stopping the servomotor by setting the speed reference to 0
A set of cables including a cable for connecting serial converter unit, a cable for connecting linear scale, and a cable for connecting hall sensor
IMPORTANT Explanations
The following icon is displayed for explanations requiring special attention.
• Indicates important information that should be memorized, as well as precautions, such as alarm displays, that do not involve potential damage to equipment. iii
iv
Notation Used in this Manual
• Notation for Reverse Signals
The names of reverse signals (i.e., ones that are valid when low) are written with a forward slash (/) before the signal name.
Notation Example
BK = /BK
• Notation for Parameters
The notation depends on whether the parameter requires a value setting (parameter for numeric settings) or requires the selection of a function (parameter for selecting functions).
• Parameters for Numeric Settings
Control methods for which the parameter applies.
Speed : Speed control Position : Position control Force : Force control
Pn311
Vibration Detection Sensitivity
Setting Range
50 to 500
Setting Unit
1%
Speed
Factory Setting
100
Position Force
When Enabled
Immediately
Parameter number
Indicates the setting range for the parameter.
Indicates the minimum setting unit for the parameter.
Indicates the parameter setting before shipment.
Indicates when a change to the parameter will be effective.
Classification
Tuning
Indicates the parameter classification.
• Parameters for Selecting Functions
Pn002
Parameter n.
0
[Factory setting] n.
1
Meaning
Uses the absolute linear scale as an absolute linear scale.
Uses the absolute linear scale as an incremental linear scale.
Parameter number
When Enabled
After restart
Classification
The notation “n.
” indicates a parameter for selecting functions. Each corresponds to the setting value of that digit. The notation shown here means that the third digit is 1.
This section explains the selections for the function.
Setup
Notation Example
Digital Operator Display (Display Example for Pn002)
㨚㧜㧜㧜㧜
3rd digit
4th digit
Pn002.2
Pn002.3
Digit Notation
1st digit
2nd digit
Notation
Pn002.0
Pn002.1
Meaning
Indicates the value for the
1st digit of parameter Pn002.
Indicates the value for the
2nd digit of parameter Pn002.
Indicates the value for the
3rd digit of parameter Pn002.
Indicates the value for the
4th digit of parameter Pn002.
Notation
Setting Notation
Meaning
Pn002.0 = x or n.
x
Indicates that the value for the
1st digit of parameter Pn002 is x.
Pn002.1 = x or n.
x
Indicates that the value for the
2nd digit of parameter Pn002 is x.
Pn002.2 = x or n.
x
Indicates that the value for the
3rd digit of parameter Pn002 is x.
Pn002.3 = x or n.x
Indicates that the value for the
4th digit of parameter Pn002 is x.
Manuals Related to the Σ V Series
Refer to the following manuals as required.
Name
Σ V Series
User’s Manual
Setup
Linear Motor
(No.: SIEP S800000 44)
Σ V Series
Product Catalog
(No.: KAEP S800000 42)
Σ V Series
User's Manual
Design and Maintenance
Linear Motor/
MECHATROLINKII
Communications Reference
(this manual)
Σ V Series/
DC Power Input Σ V Series/
Σ V Series for
Large-Capacity Models
User’s Manual
MECHATROLINKII
Commands
(No.: SIEP S800000 54)
Σ V Series
User’s Manual
Operation of Digital Operator
(No.: SIEP S800000 55)
Σ V Series
AC SERVOPACK SGDV
Safety Precautions
(No.: TOBP C710800 10)
Σ Series
Digital Operator
Safety Precautions
(No.: TOBP C730800 00)
AC SERVOMOTOR
Safety Precautions
(No.: TOBP C230200 00)
Selecting
Models and
Peripheral
Devices
Ratings and
Specifications
System
Design
Panels and
Wiring
Trial
Operation
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
Trial
Operation and Servo
Adjustment
Maintenance and
Inspection
−
−
−
−
−
−
−
−
Trademarks
MECHATROLINK is a trademark of the MECHATROLINK Members Association.
v
vi
Safety Information
The following conventions are used to indicate precautions in this manual. Failure to heed precautions provided in this manual can result in serious or possibly even fatal injury or damage to the products or to related equipment and systems.
WARNING
Indicates precautions that, if not heeded, could possibly result in loss of life or serious injury.
CAUTION
Indicates precautions that, if not heeded, could result in relatively serious or minor injury, damage to the product, or faulty operation.
In some situations, the precautions indicated could have serious consequences if not heeded.
PROHIBITED
Indicates prohibited actions that must not be performed. For example, this symbol would be used to indicate that fire is prohibited as follows:
MANDATORY
Indicates compulsory actions that must be performed. For example, this symbol would be used to indicate that grounding is compulsory as follows:
Safety Precautions
This section describes important precautions that must be followed during storage, transportation, installation, wiring, operation, maintenance, inspection, and disposal. Be sure to always observe these precautions thoroughly.
WARNING
• If you have a pacemaker or any other electronic medical device, do not go near the magnetic way of the servomotor.
Failure to observe this warning may result in the malfunction of the medical device.
• Be sure to use nonmagnetic tools when installing or working close to the servomotor.
(Example: a beryllium-copper alloy hexagonal wrench set, made by NGK Insulators, Ltd.)
• Never touch the servomotor or machinery during operation.
Failure to observe this warning may result in injury.
• Before starting operation with a machine connected, make sure that an emergency stop can be applied at any time.
Failure to observe this warning may result in injury or damage to the equipment.
• Before wiring, install the SERVOPACK and the servomotor.
Failure to observe this warning may result in electric shock.
• Never touch the inside of the SERVOPACKs.
Failure to observe this warning may result in electric shock.
• Do not remove the cover of the power supply terminal block while the power is ON.
Failure to observe this warning may result in electric shock.
• Do not touch the power supply terminals while the CHARGE lamp is ON after turning power OFF because high voltage may still remain in the SERVOPACK. Make sure the CHARGE lamp is OFF first before starting to do wiring or inspections.
Residual voltage may cause electric shock.
• Follow the procedures and instructions provided in the manuals for the products being used in the trial operation.
Failure to do so may result not only in faulty operation and damage to equipment, but also in personal injury.
• Do not remove the top front cover, cables, connectors, or optional items from the SERVOPACK while the power is ON.
Failure to observe this warning may result in electric shock or equipment damage.
• Do not damage, pull, exert excessive force on, or place heavy objects on the cables.
Failure to observe this warning may result in electric shock, stopping operation of the product, or fire.
• Do not modify the product.
Failure to observe this warning may result in injury, damage to the equipment, or fire.
• Provide appropriate braking devices on the machine side to ensure safety.
Failure to observe this warning may result in injury.
• Do not come close to the machine immediately after resetting an instantaneous power interruption to avoid an unexpected restart. Take appropriate measures to ensure safety against an unexpected restart.
Failure to observe this warning may result in injury.
• Connect the ground terminal according to local electrical codes (100 Ω or less for a SERVOPACK with a 100 V, 200 V power supply, 10 Ω or less for a SERVOPACK with a 400 V power supply).
Improper grounding may result in electric shock or fire.
• Installation, disassembly, or repair must be performed only by authorized personnel.
Failure to observe this warning may result in electric shock or injury.
• The person who designs a system using the safety function (Hard Wire Baseblock function) must have full knowledge of the related safety standards and full understanding of the instructions in this manual.
Failure to observe this warning may result in injury or damage to the equipment.
vii
viii
Storage and Transportation
CAUTION
• Be sure to store the magnetic way in the package that was used for delivery.
• Do not store or install the product in the following locations.
Failure to observe this caution may result in fire, electric shock, or damage to the equipment.
• Locations subject to direct sunlight
• Locations subject to temperatures outside the range specified in the storage/installation temperature conditions
• Locations subject to humidity outside the range specified in the storage/installation humidity conditions
• Locations subject to condensation as the result of extreme changes in temperature
• Locations subject to corrosive or flammable gases
• Locations subject to dust, salts, or iron dust
• Locations subject to exposure to water, oil, or chemicals
• Locations subject to shock or vibration
• Do not hold the servomotor by the cables while transporting it.
Failure to observe this caution may result in injury or malfunction.
• Do not place any load exceeding the limit specified on the packing box.
Failure to observe this caution may result in injury or malfunction.
• If disinfectants or insecticides must be used to treat packing materials such as wooden frames, pallets, or plywood, the packing materials must be treated before the product is packaged, and methods other than fumigation must be used.
Example: Heat treatment, where materials are kiln-dried to a core temperature of 56 ° C for 30
minutes or more.
If the electronic products, which include stand-alone products and products installed in machines, are packed with fumigated wooden materials, the electrical components may be greatly damaged by the gases or fumes resulting from the fumigation process. In particular, disinfectants containing halogen, which includes chlorine, fluorine, bromine, or iodine can contribute to the erosion of the capacitors.
Installation
CAUTION
• When unpacking and installing magnetic way, check that no metal fragments or magnetized objects near the magnetic because they may be affected by the magnetic attraction of the magnetic way.
Failure to observe this caution may result in injury or damage to the magnetic way's magnets.
• Do not use the magnetic way near metal or other magnetized objects.
Failure to observe this caution may result in injury.
• Do not place clocks, magnetic cards, floppy disks, or measuring instruments close to the magnetic way.
Failure to observe this caution may result in malfunction or damage to these items by the magnetic force.
• Securely mount the servomotor onto the machine.
If the servomotor is not mounted securely, it may loosen during operation.
• Do not carry the magnetic way by its magnet protection cover.
Failure to observe this caution may result in injury by the cover’s edge or the shape of the cover may become distorted.
Cover
Magnetic way
• When removing the dummy plate for reducing magnetic force used for the SGLFW magnetic way, pay attention to the magnetic attraction of the magnetic way. Do not place the removed plate close to the magnetic way.
Failure to observe this caution may result in injury or damage to the magnetic way’s magnets or the magnet protection cover.
• Install SERVOPACKs, servomotors, and regenerative resistors on nonflammable objects.
Installation directly onto or near flammable objects may result in fire.
• Never use the product in an environment subject to water, corrosive gases, flammable gases, or combustibles.
Failure to observe this caution may result in electric shock or fire.
• Do not step on or place a heavy object on the product.
Failure to observe this caution may result in injury or malfunction.
• Do not cover the inlet or outlet ports and prevent any foreign objects from entering the product.
Failure to observe this caution may cause internal elements to deteriorate resulting in malfunction or fire.
• Be sure to install the product in the correct direction.
Failure to observe this caution may result in malfunction.
• Provide the specified clearances between the SERVOPACK and the control panel or with other devices.
Failure to observe this caution may result in fire or malfunction.
• Do not apply any strong impact.
Failure to observe this caution may result in malfunction.
ix
x
Wiring
CAUTION
• Be sure to wire correctly and securely.
Failure to observe this caution may result in motor overrun, injury, or malfunction.
• Securely tighten the cable connector screws and securing mechanism.
If the connector screws and securing mechanism are not secure, they may loosen during operation.
• Use cables with a radius, heat resistance, and flexibility suitable for the system.
• If the SERVOPACK malfunctions, turn OFF the main circuit’s power supply of the SERVOPACK.
The continuous flow of a large current may cause fire.
• Use a noise filter to minimize the effects of electromagnetic damage.
Failure to observe this caution may result in electromagnetic damage to electronic devices used near the SER-
VOPACK.
• Do not connect a commercial power supply to the U, V, or W terminals for the servomotor connection.
Failure to observe this caution may result in injury or fire.
• Securely connect the main circuit terminals.
Failure to observe this caution may result in fire.
• Do not bundle or run the main circuit cables together with the I/O signal cables or the linear scale connection cables in the same duct. Keep the main circuit cables separated from the I/O signal cables and the linear scale connection cables with a gap of at least 30 cm.
Placing these cables too close to each other may result in malfunction.
• Use shielded twisted-pair cables or screened unshielded twisted-pair cables for I/O signal cables and the linear scale connection cables.
• Make sure that the length of each cable is equal to or shorter than the maximum wiring length listed here.
• I/O signal cables: 3 m
• Connection cables for linear servomotor main circuit: 20 m
• Connection cables for serial converter unit: 20 m
• Connection cables for linear scale: 15 m
• Connection cables for hall sensor: 15 m
• Control power supply cables for the SERVOPACK with a 400-V power supply (+24 V, 0 V):10 m
• Be sure to observe the following precautions when wiring the SERVOPACK main circuit terminal blocks.
• Do not turn the SERVOPACK power ON until all wiring, including the main circuit terminal blocks, has been completed.
• If a connector is used for the main circuit terminals, remove the connector from the SERVOPACK before you wire it.
• Insert only one wire into one opening in the main circuit connector.
• Make sure that no part of the core wire comes into contact with (i.e., short-circuits) adjacent wires.
• Do not connect the SERVOPACK for 200 V directly to a voltage of 400 V.
The SERVOPACK will be destroyed.
• When connecting an External Regenerative Resistor to the SGDV-3R8A, -5R5A, -7R6A, -120A,
-180A, -200A, -330A, -1R9D, -3R5D, -5R4D, -8R4D, -120D, or -170D, first remove the lead wire between the B2 and B3 terminals on the SERVOPACK, and then connect the External Regenerative Resistor.
There is a risk of SERVOPACK failure.
• Always use the specified power supply voltage.
An incorrect voltage may result in fire or malfunction.
• Make sure that the polarity is correct.
Incorrect polarity may cause ruptures or damage.
• Take appropriate measures to ensure that the input power supply is supplied within the specified voltage fluctuation range. Be particularly careful in places where the power supply is unstable.
An incorrect power supply may result in damage to the equipment.
• Install external breakers or other safety devices against short-circuiting in external wiring.
Failure to observe this caution may result in fire.
• Take appropriate and sufficient countermeasures for each form of potential interference when installing systems in the following locations.
• Locations subject to static electricity or other forms of noise
• Locations subject to strong electromagnetic fields and magnetic fields
• Locations subject to possible exposure to radioactivity
• Locations close to power supplies
Failure to observe this caution may result in damage to the equipment.
• Wiring or inspection must be performed by a technical expert.
• Use a 24-VDC power supply with double insulation or reinforced insulation.
Operation
CAUTION
• Do not stand within the machine's range of motion during operation.
Failure to observe this caution may result in injury.
• Always use the servomotor and SERVOPACK in one of the specified combinations.
Failure to observe this caution may result in fire or malfunction.
• Before operation, install limit switches or stoppers at the ends of the range of movement to prevent unexpected accidents.
Failure to observe this caution may result in injury.
• During trial operation, confirm that the holding brake works correctly. Furthermore, secure system safety against problems such as signal line disconnection.
Failure to observe this caution may result in injury or equipment damage.
• Before starting operation with a machine connected, change the parameter settings to match the parameters of the machine.
Starting operation without matching the proper settings may cause the machine to run out of control or malfunction.
• Do not turn the power ON and OFF more than necessary.
Do not use the SERVOPACK for applications that require the power to turn ON and OFF frequently. Such applications will cause elements in the SERVOPACK to deteriorate.
As a guideline, at least one hour should be allowed between the power being turned ON and OFF once actual operation has been started.
• When carrying out JOG operation (Fn002), origin search (Fn003), or EasyFFT (Fn206), forcing movable machine parts to stop does not work for forward overtravel or reverse overtravel. Take necessary precautions.
Failure to observe this caution may result in damage to the equipment.
• When using the servomotor for a vertical axis, install safety devices to prevent workpieces from falling due to alarms or overtravels. Set the servomotor so that it will stop in the zero clamp state when overtravel occurs.
Failure to observe this caution may cause workpieces to fall due to overtravel.
• When not using the turning-less function, set the correct mass ratio (Pn103).
Setting an incorrect mass ratio may cause machine vibration.
• Do not touch the SERVOPACK heat sinks, regenerative resistor, or servomotor while power is ON or soon after the power is turned OFF.
Failure to observe this caution may result in burns due to high temperatures.
• Do not make any extreme adjustments or setting changes of parameters.
Failure to observe this caution may result in injury or damage to the equipment due to unstable operation.
• If an alarm occurs, shut down the main circuit power supply.
Failure to observe this caution may result in fire due to regenerative resistor overheating caused by regenerative transistor failure.
• When an alarm occurs, remove the cause, reset the alarm after confirming safety, and then resume operation.
Failure to observe this caution may result in damage to the equipment, fire, or injury.
• An alarm or warning may occur if communications are performed with the host controller while the
SigmaWin+ or Digital Operator is operating.
If an alarm or warning occurs, it may stop the current process and stop the system.
Maintenance and Inspection
CAUTION
• Do not disassemble the SERVOPACK and the servomotor.
Failure to observe this caution may result in electric shock or injury.
• Do not attempt to change wiring while the power is ON.
Failure to observe this caution may result in electric shock or injury.
• When replacing the SERVOPACK, resume operation only after copying the previous SERVOPACK parameters to the new SERVOPACK.
Failure to observe this caution may result in damage to the equipment.
xi
xii
Disposal Precautions
CAUTION
• Correctly discard the product as stipulated by regional, local, and municipal laws and regulations. Be sure to include these contents in all labelling and warning notifications on the final product as necessary.
General Precautions
Observe the following general precautions to ensure safe application.
• The products shown in illustrations in this manual are sometimes shown without covers or protective guards.
Always replace the cover or protective guard as specified first, and then operate the products in accordance with the manual.
• The drawings presented in this manual are typical examples and may not match the product you received.
• If the manual must be ordered due to loss or damage, inform your nearest Yaskawa representative or one of the offices listed on the back of this manual.
Warranty
(1) Details of Warranty
Warranty Period
The warranty period for a product that was purchased (hereinafter called “delivered product”) is one year from the time of delivery to the location specified by the customer or 18 months from the time of shipment from the
Yaskawa factory, whichever is sooner.
Warranty Scope
Yaskawa shall replace or repair a defective product free of charge if a defect attributable to Yaskawa occurs during the warranty period above. This warranty does not cover defects caused by the delivered product reaching the end of its service life and replacement of parts that require replacement or that have a limited service life.
This warranty does not cover failures that result from any of the following causes.
1. Improper handling, abuse, or use in unsuitable conditions or in environments not described in product catalogs or manuals, or in any separately agreed-upon specifications
2. Causes not attributable to the delivered product itself
3. Modifications or repairs not performed by Yaskawa
4. Abuse of the delivered product in a manner in which it was not originally intended
5. Causes that were not foreseeable with the scientific and technological understanding at the time of shipment from Yaskawa
6. Events for which Yaskawa is not responsible, such as natural or human-made disasters
(2) Limitations of Liability
1. Yaskawa shall in no event be responsible for any damage or loss of opportunity to the customer that arises due to failure of the delivered product.
2. Yaskawa shall not be responsible for any programs (including parameter settings) or the results of program execution of the programs provided by the user or by a third party for use with programmable Yaskawa products.
3. The information described in product catalogs or manuals is provided for the purpose of the customer purchasing the appropriate product for the intended application. The use thereof does not guarantee that there are no infringements of intellectual property rights or other proprietary rights of Yaskawa or third parties, nor does it construe a license.
4. Yaskawa shall not be responsible for any damage arising from infringements of intellectual property rights or other proprietary rights of third parties as a result of using the information described in catalogs or manuals.
xiii
xiv
(3) Suitability for Use
1. It is the customer’s responsibility to confirm conformity with any standards, codes, or regulations that apply if the Yaskawa product is used in combination with any other products.
2. The customer must confirm that the Yaskawa product is suitable for the systems, machines, and equipment used by the customer.
3. Consult with Yaskawa to determine whether use in the following applications is acceptable. If use in the application is acceptable, use the product with extra allowance in ratings and specifications, and provide safety measures to minimize hazards in the event of failure.
• Outdoor use, use involving potential chemical contamination or electrical interference, or use in conditions or environments not described in product catalogs or manuals
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, vehicle systems, medical equipment, amusement machines, and installations subject to separate industry or government regulations
• Systems, machines, and equipment that may present a risk to life or property
• Systems that require a high degree of reliability, such as systems that supply gas, water, or electricity, or systems that operate continuously 24 hours a day
• Other systems that require a similar high degree of safety
4. Never use the product for an application involving serious risk to life or property without first ensuring that the system is designed to secure the required level of safety with risk warnings and redundancy, and that the
Yaskawa product is properly rated and installed.
5. The circuit examples and other application examples described in product catalogs and manuals are for reference. Check the functionality and safety of the actual devices and equipment to be used before using the product.
6. Read and understand all use prohibitions and precautions, and operate the Yaskawa product correctly to prevent accidental harm to third parties.
(4) Specifications Change
The names, specifications, appearance, and accessories of products in product catalogs and manuals may be changed at any time based on improvements and other reasons. The next editions of the revised catalogs or manuals will be published with updated code numbers. Consult with your Yaskawa representative to confirm the actual specifications before purchasing a product.
Harmonized Standards
North American Safety Standards (UL)
SERVOPACK SGDV
Model
EU Directives
UL Standards
(UL File No.)
UL508C (E147823)
SERVOPACK
Model
SGDV
European Directives
Machinery Directive
2006/42/EC
Harmonized Standards
EN ISO13849-1: 2015
EMC Directive
2014/30/EU
Low Voltage Directive
2014/35/EU
RoHS Directive
2011/65/EU
EN 55011 group1 classA
EN 61000-6-2
EN 61000-6-4
EN 61800-3 (Category C2, Second Environment)
EN 50178
EN 61800-5-1
EN 50581 xv
xvi
Safety Standards
SERVOPACK
Model
SGDV
Safety Standards
Safety of Machinery
Functional Safety
EMC
EN ISO13849-1: 2015
IEC 60204-1
IEC 61508 series
IEC 62061
IEC 61800-5-2
IEC 61326-3-1
Standards
• Safe Performance
Safety Integrity Level
Items
Probability of Dangerous Failure per Hour
Performance Level
Mean Time to Dangerous Failure of Each
Channel
Average Diagnostic Coverage
Stop Category
Safety Function
Proof test Interval
Standards
IEC 61508
IEC 62061
IEC 61508
IEC 62061
EN ISO 13849-1
EN ISO 13849-1
EN ISO 13849-1
IEC 60204-1
IEC 61800-5-2
IEC 61508
Performance Level
SIL2
SILCL2
PFH = 1.7
× 10
-9
(0.17% of SIL2)
[1/h]
PL d (Category 3)
MTTFd: High
DCavg: Low
Stop category 0
STO
10 years
Contents
About this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Safety Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii
Harmonized Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv
Chapter 1 Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
1.1 Σ V Series SERVOPACKs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1.2 Part Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1.3 SERVOPACK Ratings and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
1.3.1 Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
1.3.2 Basic Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
1.3.3 MECHATROLINKII Function Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
1.4 SERVOPACK Internal Block Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
1.4.1 Single-phase 100 V, SGDV-R70F15A, -R90F15A, -2R1F15A Models . . . . . . . . . . . . . . . 1-8
1.4.2 Single-phase 100 V, SGDV-2R8F15A Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
1.4.3 Three-phase 200 V, SGDV-R70A15 , -R90A15 , -1R6A15 Models . . . . . . . . . . . . . . 1-9
1.4.4 Three-phase 200 V, SGDV-2R8A15 Model. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
1.4.5 Three-phase 200 V, SGDV-3R8A15A, -5R5A15A, -7R6A15A Models . . . . . . . . . . . . . . 1-10
1.4.6 Three-phase 200 V, SGDV-120A15A Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
1.4.7 Three-phase 200 V, SGDV-180A15A, -200A15A Models . . . . . . . . . . . . . . . . . . . . . . . . 1-11
1.4.8 Three-phase 200 V, SGDV-330A15A Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11
1.4.9 Three-phase 200 V, SGDV-550A15A Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
1.4.10 Three-phase 400 V, SGDV-1R9D15A, -3R5D15A, -5R4D15A Models . . . . . . . . . . . . . 1-12
1.4.11 Three-phase 400 V, SGDV-8R4D15A, -120D15A Models . . . . . . . . . . . . . . . . . . . . . . . 1-13
1.4.12 Three-phase 400 V, SGDV-170D15A Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13
1.4.13 Three-phase 400 V, SGDV-260D15A Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14
1.5 Examples of Servo System Configurations . . . . . . . . . . . . . . . . . . . . . . . . . 1-15
1.5.1 Connecting to SGDV F15A SERVOPACK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-15
1.5.2 Connecting to SGDV A15 SERVOPACK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-16
1.5.3 Connecting to SGDV D15A SERVOPACK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-18
1.6 SERVOPACK Model Designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19
1.7 Servo Drive Maintenance and Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . 1-20
1.7.1 SERVOPACK Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-20
1.7.2 SERVOPACK’s Parts Replacement Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-20
1.7.3 Servomotor Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-21
Chapter 2 Panel Display and Operation of Digital Operator . . . . . . . . . . . .2-1
2.1 Panel Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.1 Status Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.2 Alarm and Warning Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.3 Hard Wire Base Block Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.4 Overtravel Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.2 Operation of Digital Operator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.3 Utility Functions (Fn ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.4 Parameters (Pn ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
2.4.1 Parameter Classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
2.4.2 Notation for Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
2.4.3 Setting Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2.5 Monitor Displays (Un ). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 xvii
xviii
Chapter 3 Wiring and Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
3.1 Main Circuit Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3.1.1 Main Circuit Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3.1.2 Using a Standard Power Supply
(Single-phase 100 V, Three-phase 200 V, or Three-phase 400 V) . . . . . . . . . . . . . . . . . . 3-3
3.1.3 Using the SERVOPACK with Single-phase, 200 V Power Input . . . . . . . . . . . . . . . . . . . 3-11
3.1.4 Using the SERVOPACK with a DC Power Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14
3.1.5 Using More Than One SERVOPACK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18
3.1.6 General Precautions for Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19
3.2 I/O Signal Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-20
3.2.1 I/O Signal (CN1) Names and Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-20
3.2.2 Safety Function Signal (CN8) Names and Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-21
3.2.3 Example of I/O Signal Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-22
3.3 I/O Signal Allocations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23
3.3.1 Input Signal Allocations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23
3.3.2 Output Signal Allocations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-25
3.4 Examples of Connection to Host Controller . . . . . . . . . . . . . . . . . . . . . . . . . 3-26
3.4.1 Sequence Input Circuit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-26
3.4.2 Sequence Output Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-27
3.5 Wiring MECHATROLINKII Communications. . . . . . . . . . . . . . . . . . . . . . . . 3-29
3.6 Linear Scale Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-30
3.6.1 Linear Scale Signal (CN2) Names and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-30
3.6.2 Serial Converter Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-30
3.6.3 Linear Scale Connection Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-33
3.7 Connecting Regenerative Resistors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-37
3.7.1 Connecting Regenerative Resistors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-37
3.7.2 Setting Regenerative Resistor Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-39
3.8 Noise Control and Measures for Harmonic Suppression . . . . . . . . . . . . . . . 3-40
3.8.1 Wiring for Noise Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-40
3.8.2 Precautions on Connecting Noise Filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-42
3.8.3 Connecting a Reactor for Harmonic Suppression . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-43
Chapter 4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1
4.1 MECHATROLINKII Communications Settings . . . . . . . . . . . . . . . . . . . . . . . 4-3
4.1.1 Setting the Communications Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
4.1.2 Setting the Station Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
4.2 MECHATROLINKII Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
4.3 Basic Functions Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
4.3.1 Servomotor Movement Direction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
4.3.2 Overtravel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
4.3.3 Software Limit Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
4.3.4 Holding Brakes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
4.3.5 Stopping Servomotors after SV_OFF Command or Alarm Occurrence. . . . . . . . . . . . . . 4-14
4.3.6 Instantaneous Power Interruption Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16
4.3.7 Motor Maximum Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17
4.3.8 SEMI F47 Function
(Force Limit Function for Low DC Power Supply Voltage for Main Circuit) . . . . . . . . . . . 4-18
4.3.9 Setting Motor Overload Detection Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21
4.4 Trial Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-23
4.4.1 Inspection and Checking before Trial Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-23
4.4.2 Trial Operation via MECHATROLINKII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24
4.4.3 Electronic Gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-25
4.4.4 Encoder Output Pulses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-28
4.4.5 Setting Encoder Output Pulse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-33
4.5 Test Without Motor Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-35
4.5.1 Motor Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-35
4.5.2 Motor Position and Speed Responses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-36
4.5.3 Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-36
4.5.4 Digital Operator Displays during Testing without Motor . . . . . . . . . . . . . . . . . . . . . . . . . . 4-37
4.6 Limiting Force . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-38
4.6.1 Internal Force Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-38
4.6.2 External Force Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-39
4.6.3 Checking Output Force Limiting during Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-40
4.7 Absolute Linear Scales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-41
4.7.1 Absolute Data Request (SENS ON Command) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-41
4.7.2 Absolute Data Reception Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-42
4.7.3 Absolute Encoder Origin Offset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-45
4.8 Other Output Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-46
4.8.1 Servo Alarm Output Signal (ALM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-46
4.8.2 Warning Output Signal (/WARN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-46
4.8.3 Movement Detection Output Signal (/TGON). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-47
4.8.4 Servo Ready Output Signal (/S-RDY) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-47
4.8.5 Speed Coincidence Output Signal (/V-CMP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-49
4.8.6 Positioning Completed Output Signal (/COIN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-50
4.8.7 Positioning Near Output Signal (/NEAR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-51
4.8.8 Speed Limit Detection Signal (/VLT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-52
4.9 Safety Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-54
4.9.1 Hard Wire Base Block (HWBB) Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-54
4.9.2 External Device Monitor (EDM1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-60
4.9.3 Application Example of Safety Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-62
4.9.4 Confirming Safety Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-63
4.9.5 Safety Device Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-64
4.9.6 Precautions for Safety Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-65
Chapter 5 Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-1
5.1 Type of Adjustments and Basic Adjustment Procedure . . . . . . . . . . . . . . . . . 5-3
5.1.1 Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
5.1.2 Basic Adjustment Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-4
5.1.3 Monitoring Operation during Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5
5.1.4 Safety Precautions on Adjustment of Servo Gains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-8
5.2 Tuning-less Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-10
5.2.1 Tuning-less Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-10
5.2.2 Tuning-less Levels Setting (Fn200) Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-13
5.2.3 Related Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-15
5.3 Advanced Autotuning (Fn201) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16
5.3.1 Advanced Autotuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16
5.3.2 Advanced Autotuning Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19
5.3.3 Related Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25
5.4 Advanced Autotuning by Reference (Fn202). . . . . . . . . . . . . . . . . . . . . . . . 5-26
5.4.1 Advanced Autotuning by Reference. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-26
5.4.2 Advanced Autotuning by Reference Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-28
5.4.3 Related Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-32
5.5 One-parameter Tuning (Fn203) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-33
5.5.1 One-parameter Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-33
5.5.2 One-parameter Tuning Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-34
5.5.3 One-parameter Tuning Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-40
5.5.4 Related Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-42
5.6 Anti-Resonance Control Adjustment Function (Fn204) . . . . . . . . . . . . . . . . 5-43
5.6.1 Anti-Resonance Control Adjustment Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-43
5.6.2 Anti-Resonance Control Adjustment Function Operating Procedure. . . . . . . . . . . . . . . . 5-44
5.6.3 Related Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-48 xix
xx
5.7 Vibration Suppression Function (Fn205) . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-49
5.7.1 Vibration Suppression Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-49
5.7.2 Vibration Suppression Function Operating Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . 5-50
5.7.3 Related Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-53
5.8 Additional Adjustment Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-54
5.8.1 Switching Gain Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-54
5.8.2 Manual Adjustment of Friction Compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-58
5.8.3 Current Control Mode Selection Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-60
5.8.4 Current Gain Level Setting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-60
5.8.5 Speed Detection Method Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-60
5.9 Compatible Adjustment Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-61
5.9.1 Feedforward Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-61
5.9.2 Mode Switch (P/PI Switching) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-62
5.9.3 Force Reference Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-64
5.9.4 Position Integral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-66
Chapter 6 Utility Functions (Fn ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-1
6.1 List of Utility Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
6.2 Alarm History Display (Fn000) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
6.3 JOG Operation (Fn002) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
6.4 Origin Search (Fn003) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
6.5 Program JOG Operation (Fn004). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8
6.6 Initializing Parameter Settings (Fn005) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-12
6.7 Clearing Alarm History (Fn006) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-13
6.8 Offset Adjustment of Analog Monitor Output (Fn00C) . . . . . . . . . . . . . . . . . 6-14
6.9 Gain Adjustment of Analog Monitor Output (Fn00D) . . . . . . . . . . . . . . . . . . 6-16
6.10 Automatic Offset-Signal Adjustment of the Motor Current Detection
Signal (Fn00E) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-18
6.11 Manual Offset-Signal Adjustment of the Motor Current Detection
Signal (Fn00F) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-19
6.12 Write Prohibited Setting (Fn010) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-21
6.13 Servomotor Model Display (Fn011) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-23
6.14 Software Version Display (Fn012) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-24
6.15 Resetting Configuration Errors in Option Modules (Fn014) . . . . . . . . . . . . 6-25
6.16 Vibration Detection Level Initialization (Fn01B) . . . . . . . . . . . . . . . . . . . . . 6-26
6.17 Display of SERVOPACK and Servomotor ID (Fn01E) . . . . . . . . . . . . . . . . 6-28
6.18 Origin Setting (Fn020) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-30
6.19 Software Reset (Fn030) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-31
6.20 Polarity Detection (Fn080) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-32
6.21 EasyFFT (Fn206) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-33
6.22 Online Vibration Monitor (Fn207) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-36
Chapter 7 Monitor Displays (Un ) . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-1
7.1 List of Monitor Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
7.2 Viewing Monitor Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3
7.3 Monitoring Input Signals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4
7.3.1 Interpreting Input Signal Display Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4
7.3.2 Input Signal Display Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-5
7.4 Monitoring Output Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6
7.4.1 Interpreting Output Signal Display Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6
7.4.2 Output Signal Display Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6
7.5 Monitoring Safety Input Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7
7.5.1 Interpreting Safety Input Signal Display Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7
7.5.2 Safety Input Signal Display Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7
Chapter 8 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-1
8.1 Alarm Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
8.1.1 List of Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
8.1.2 Troubleshooting of Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6
8.2 Warning Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-24
8.2.1 List of Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-24
8.2.2 Troubleshooting of Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-25
8.3 Monitoring Communication Data on Occurrence of an Alarm or Warning . . 8-29
8.4 Troubleshooting Malfunction Based on Operation and Conditions of the Servomotor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-30
Chapter 9 Appendix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-1
9.1 List of Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2
9.2 Parameter Recording Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-32
Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Index-1
Revision History xxi
1
Outline
1.1 Σ V Series SERVOPACKs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1.2 Part Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1.3 SERVOPACK Ratings and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
1.3.1 Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
1.3.2 Basic Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
1.3.3 MECHATROLINKII Function Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
1.4 SERVOPACK Internal Block Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
1.4.1 Single-phase 100 V, SGDV-R70F15A, -R90F15A, -2R1F15A Models . . . . . . . . . . . . 1-8
1.4.2 Single-phase 100 V, SGDV-2R8F15A Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
1.4.3 Three-phase 200 V, SGDV-R70A15 , -R90A15 , -1R6A15 Models . . . . . . . . . . . 1-9
1.4.4 Three-phase 200 V, SGDV-2R8A15 Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
1.4.5 Three-phase 200 V, SGDV-3R8A15A, -5R5A15A, -7R6A15A Models . . . . . . . . . . . 1-10
1.4.6 Three-phase 200 V, SGDV-120A15A Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
1.4.7 Three-phase 200 V, SGDV-180A15A, -200A15A Models . . . . . . . . . . . . . . . . . . . . . 1-11
1.4.8 Three-phase 200 V, SGDV-330A15A Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11
1.4.9 Three-phase 200 V, SGDV-550A15A Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
1.4.10 Three-phase 400 V, SGDV-1R9D15A, -3R5D15A, -5R4D15A Models . . . . . . . . . . 1-12
1.4.11 Three-phase 400 V, SGDV-8R4D15A, -120D15A Models . . . . . . . . . . . . . . . . . . . 1-13
1.4.12 Three-phase 400 V, SGDV-170D15A Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13
1.4.13 Three-phase 400 V, SGDV-260D15A Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14
1.5 Examples of Servo System Configurations . . . . . . . . . . . . . . . . . . . . . . . 1-15
1.5.1 Connecting to SGDV F15A SERVOPACK . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-15
1.5.2 Connecting to SGDV A15 SERVOPACK . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-16
1.5.3 Connecting to SGDV D15A SERVOPACK . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-18
1.6 SERVOPACK Model Designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19
1.7 Servo Drive Maintenance and Inspection . . . . . . . . . . . . . . . . . . . . . . . . 1-20
1.7.1 SERVOPACK Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-20
1.7.2 SERVOPACK’s Parts Replacement Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-20
1.7.3 Servomotor Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-21
1
1-1
1-2
1 Outline
1.1
Σ -
V
Series SERVOPACKs
The Σ -V Series SERVOPACKs are designed for applications that require frequent high-speed, high-precision positioning. The SERVOPACK makes the most of machine performance in the shortest time possible, thus contributing to improving productivity.
1.2
Part Names
This section describes the part names of SGDV SERVOPACK for MECHATROLINK-II communications reference.
CN5 Analog monitor connector
Used to monitor motor speed, force reference, and other values through a special cable (option).
Refer to 5.1.3 Monitoring Operation during
Adjustment .
Serial number
Rotary switch (SW 1)
Used to set the MECHATROLINKII station address.
Refer to 4.1.1 Setting the Communications Spec-
DIP switch (SW 2)
Used to set MECHATROLINKII communications.
Refer to 4.1.1 Setting the Communications Spec-
Nameplate (Found on side of SERVOPACK.)
Indicates the SERVOPACK model and ratings.
Charge indicator
Lights when the main circuit power supply is ON and stays lit as long as the internal capacitor remains charged. Therefore, do not touch the
SERVOPACK even after the power supply is turned OFF if the indicator is lit.
It may result in electric shock.
Main circuit power supply terminals
Used for main circuit power supply input.
Refer to 3.1 Main Circuit Wiring .
Control power supply terminals
Used for control power supply input.
Refer to 3.1 Main Circuit Wiring .
Regenerative resistor connecting terminals
Connects external regenerative resistors.
Refer to 3.7 Connecting Regenerative Resistors .
DC reactor terminals for harmonic suppression
Connects DC reactor for harmonic suppression.
Refer to 3.8.3 Connecting a Reactor for Harmonic
Suppression .
Servomotor terminals
Connects the main circuit cable for servomotor.
Refer to 3.1 Main Circuit Wiring .
Ground terminal
Be sure to connect to protect against electrical shock.
Refer to 3.1 Main Circuit Wiring .
With front cover open Power LED indicator (POWER)
Indicates that the control power is being supplied.
Communications LED indicator (COM)
Indicates that data is being transmitted between the SERVOPACK and the MECHATROLINKII system.
Panel display
Indicates the servo status with a seven-segment LED display.
Refer to 2.1.1 Status Display .
Input voltage
Front cover
SERVOPACK model
Refer to 1.6 SERVOPACK Model Designation .
MECHATROLINKII communications connectors
Connects MECHATROLINKII -supported devices.
Refer to 3.5 Wiring MECHATROLINKII Communications .
CN3 Connector for digital operator
Connects a digital operator (option, model: JUSP-
OP05A-1-E) or a personal computer (RS422).
Refer to Σ V Series Product Catalog (No.: KAEP
S800000 42) and Σ V Series User’s Manual, Operation of Digital Operator (No.: SIEP S800000 55).
CN7 Connector for personal computer
(USB connector)
Communicates with a personal computer.
Use the connection cable (model: JZSP-CVS06-02-E).
CN1 I/O signal connector
Used to connect sequence I/O signals.
Refer to 3.2 I/O Signal Connections .
CN8 Connector for safety function devices
Connects a safety function device.
Note: When not using a safety function device, use the
SERVOPACK with the safety function’s jumper connector inserted (the factory default state).
For the connecting method, refer to 3.2.2 Safety
Function Signal (CN8) Names and Functions .
For details on how to use the safety function, refer to 4.9 Safety Function .
CN2 Linear scale connector
Connects a serial converter unit or a linear scale.
Refer to 3.6 Linear Scale Connection .
1.3 SERVOPACK Ratings and Specifications
1.3
SERVOPACK Ratings and Specifications
This section describes the ratings and specifications of SERVOPACKs.
1.3.1
Ratings
Ratings of SERVOPACKs are as shown below.
(1) SGDV with Single-phase, 100-V Rating
SGDV (Single Phase, 100 V)
Continuous Output Current [Arms]
Instantaneous Max. Output Current [Arms]
Regenerative Resistor *
Main Circuit Power Supply
Control Power Supply
Overvoltage Category
R70
0.66
2.1
None or external
R90
0.91
2.9
2R1
2.1
6.5
2R8
2.8
9.3
Single-phase, 100 to 115 VAC, +10% to -15%, 50/60 Hz
Single-phase, 100 to 115 VAC, +10% to -15%, 50/60 Hz
III
∗ Refer to 3.7 Connecting Regenerative Resistors for details.
(2) SGDV with Three-phase, 200-V Rating
SGDV
(Three Phase, 200 V)
Continuous Output Current
[Arms]
Instantaneous Max. Output
Current [Arms]
R70 R90 1R6 2R8 3R8 5R5 7R6
0.66
2.1
0.91
2.9
1.6
5.8
2.8
9.3
3.8
11.0
5.5
16.9
7.6
17
120
11.6
28
Regenerative Resistor
* None or external
III
Built-in or external
Main Circuit Power Supply Three-phase, 200 to 230 VAC, +10% to -15%, 50/60 Hz
Control Power Supply Single-phase, 200 to 230 VAC, +10% to -15%, 50/60 Hz
Overvoltage Category
180
18.5
42
200
19.6
56
330
32.9
84
550
54.7
130
External
∗ Refer to 3.7 Connecting Regenerative Resistors for details.
(3) SGDV with Three-phase, 400-V Rating
SGDV
(Three Phase, 400 V)
Continuous Output Current
[Arms]
Instantaneous Max. Output
Current [Arms]
1R9
1.9
5.5
3R5
3.5
8.5
5R4
5.4
14
8R4
8.4
20
120
11.9
28
Regenerative Resistor
* Built-in or external
Main Circuit Power Supply Three-phase, 380 to 480 VAC, +10% to -15%, 50/60 Hz
Control Power Supply 24 VDC ± 15%
Overvoltage Category III
∗ Refer to 3.7 Connecting Regenerative Resistors for details.
170
16.5
42
260
25.7
65
External
1
1-3
1-4
1 Outline
1.3.2 Basic Specifications
1.3.2
Basic Specifications
Basic specifications of SERVOPACKs are shown below.
Drive Method
Feedback
Sine-wave current drive with PWM control of IGBT
• Absolute linear scale
Signal resolution
*1
=
Linear scale pitch of absolute linear scale
Number of divisions on absolute linear scale
• Incremental linear scale
Signal resolution
*2
=
Linear scale pitch of incremental linear scale
Number of divisions on serial converter unit
Operating
Conditions
Ambient Operating Temperature
Storage Temperature
0 ° C to +55 ° C
Ambient Humidity
Storage Humidity
Vibration Resistance
Shock Resistance
-20 ° C to +85 ° C
90% RH or less
With no freezing or condensation
90% RH or less
4.9 m/s
2
19.6 m/s
2
Protection Class
Pollution Degree
IP10
2
An environment that satisfies the following conditions.
• Free of corrosive or flammable gases
• Free of exposure to water, oil, or chemicals
• Free of dust, salts, or iron dust
Mounting
Performance
Altitude
Others
Harmonized Standards
1000 m or less
Free of static electricity, strong electromagnetic fields, magnetic fields or exposure to radioactivity
Refer to Harmonized Standards in the preface for details.
Standard: Base-mounted
Optional: Rack-mounted or duct-ventilated
Speed Control Range
1:5000 (The lower limit of the speed control range must be lower than the point at which the rated force does not cause the servomotor to stop.)
Speed
Regulation
*3
Load
Regulation
Voltage
Regulation
Temperature
Regulation
Force Control
Tolerance
(Repeatability)
0% to 100% load: ± 0.01% max. (at rated speed)
Rated voltage ± 10%: 0% (at rated speed)
25 ± 25
± 1%
° C: ± 0.1% max. (at rated speed)
Soft Start Time
Setting
*6
0 to 10 s (Can be set individually for acceleration and deceleration.)
1.3 SERVOPACK Ratings and Specifications
I/O
Signals
Communications
Function
LED Display
Sequence
Output
Output
Signals which can be allocated
Interface
(cont’d)
Encoder Output Pulse
Phase A, B, C: line driver
Encoder output pulse: any setting ratio (Refer to 4.4.5
.)
Number of
Channels
7 ch
Sequence
Input
Input
Signals which can be allocated
Functions
• Homing deceleration switch (/DEC)
• External latch (/EXT 1 to 3)
• Forward run prohibited (P-OT), reverse run prohibited (N-
OT)
• Forward external force limit (/P-CL), reverse external force limit (/N-CL)
Signal allocations can be performed, and positive and negative logic can be changed.
Fixed Output Servo alarm (ALM) output
Number of
Channels
3 ch
Functions
• Positioning completion (/COIN)
• Speed coincidence detection (/V-CMP)
• Movement detection (/TGON)
• Servo ready (/S-RDY)
• Force limit detection (/CLT)
• Speed limit detection (/VLT)
• Brake (/BK)
• Warning (/WARN)
• Near (/NEAR)
Signal allocations can be performed, and positive and negative logic can be changed.
Digital operator (model: JUSP-OP05A-1-E)
Personal computer (can be connected with SigmaWin+)
RS422A
Communications
(CN3)
USB
Communications
(CN7)
1:N
Communications
Axis
Address
Setting
Interface
Communications
Standard
N = Up to 15 stations possible at RS422A
Set by parameter
Personal computer (can be connected with SigmaWin+)
Complies with standard USB1.1. (12 Mbps)
MECHATROLINKII
Communications Setting Switches
Panel display (seven-segment), CHARGE, POWER, and COM indicators
Rotary
Switch
(SW1)
DIP Switch
(SW2)
Position: 16 positions (Refer to 4.1.2
Number of pins: Four pins (Refer to
)
4.1.1
)
Analog Monitor (CN5)
Dynamic Brake (DB)
Regenerative Processing
Overtravel Prevention (OT)
Protective Function
Number of points: 2
Output voltage: ± 10VDC (linearity effective range ± 8 V)
Resolution: 16 bits
Accuracy: ± 20 mV (Typ)
Max. output current:
Settling time (
± 10 mA
± 1%): 1.2 ms (Typ)
Activated when a servo alarm or overtraveling occurs or when the power supply for the main circuit or servomotor is OFF.
Included
*4
Dynamic brake stop, deceleration to a stop, or free run to a stop at P-OT or
N-OT
Overcurrent, overvoltage, insufficient voltage, overload, regeneration error, and so on.
1
1-5
1-6
1 Outline
1.3.2 Basic Specifications
Utility Function
Safety Function
Input
Output
Standards
*5
Gain adjustment, alarm history, JOG operation, origin search, and so on.
/HWBB1, /HWBB2: Baseblock signal for power module
EDM1: Monitoring status of internal safety circuit (fixed output)
(cont’d)
EN ISO13849-1 PL d (Category 3), IEC61508 SIL2
Safety module Option Module
∗1.
The signal resolution depends on the absolute linear scale being used. For details, refer to 4.4.3 Electronic Gear .
∗2.
The signal resolution depends on the serial converter unit and linear scale being used. For details, refer to 3.6.2 Serial
Converter Unit and 4.4.3 Electronic Gear .
∗3.
Speed regulation by load regulation is defined as follows:
Speed regulation =
No-load motor speed Total load motor speed
Rated motor speed
×
100%
∗4.
Refer to 1.3.1 Ratings for details on regenerative resistors.
∗5.
Perform risk assessment for the system and be sure that the safety requirements are fulfilled.
∗6.
Refer to 4.2.10 Velocity Control (VELCTRL: 3CH) in the on the soft start function.
Σ -V Series/DC Power Input Σ -V Series/ Σ -V Series for
Large-Capacity Models User’s Manual MECHATROLINK-II Commands (Manual No.: SIEP S800000 54) for details
1.3 SERVOPACK Ratings and Specifications
1.3.3
MECHATROLINK-
II
Function Specifications
The following table shows the specifications of MECHATROLINK-II.
MECHATROLINKII
Communication
Reference Method
Function
Communication Protocol
MECHATROLINK-II
Specifications
Station Address
Reference Input
41h to 5Fh (Max. number of stations: 30)
Can be selected by the combination of the rotary switch
(SW1) and the DIP switch (SW2).
Baud Rate
Control Method
10 Mbps, 4 Mbps
Can be selected by the DIP switch (SW2).
Transmission Cycle 250 μ s, 0.5 to 4.0 ms (Multiples of 0.5 ms)
Number of Transmission Bytes
17 bytes per station or 32 bytes per station
Can be selected by the DIP switch (SW2).
Position, speed, or force control with MECHATROLINK-II communication
MECHATROLINK-I, MECHATROLINK-II commands
(sequence, motion, data setting/reference, monitoring, or adjustment)
1
1-7
1-8
1 Outline
1.4.1 Single-phase 100 V, SGDV-R70F15A, -R90F15A, -2R1F15A Models
1.4
SERVOPACK Internal Block Diagrams
1.4.1
Single-phase 100 V, SGDV-R70F15A, -R90F15A, -2R1F15A Models
B1/ B2
Fan
Main circuit power supply
L1
Varistor
L2
L1C Varistor
Control power supply
L2C
Voltage sensor
Relay drive
+
–
Control power supply
+
–
+
– CHARGE
Voltage sensor
±
12 V
+5 V
+17 V
Servomotor
Gate drive
Temperature sensor overcurrent protector
Current sensor
+ 12 V
U
V
W
Dynamic brake circuit
ASIC
(PWM control, etc.)
M
ENC
CN2
Analog voltage converter
CN5
CN1
Analog monitor output
Encoder output pulse
Panel display
CN3
Digital operator
CN7
Personal computer
1.4.2
Single-phase 100 V, SGDV-2R8F15A Model
CPU
(Position/speed calculation, etc.)
I/O
CN6A
I/F
CN8
CN6B
Signal for safety function
I/O signal
MECHATROLINKII communications
B1/ B2 Fan
L1 Varistor
Main circuit power supply
L2
L1C Varistor
Control power supply
L2C
Voltage sensor
Relay drive
+
–
Control power supply
+
–
+
– CHARGE
Voltage sensor
±
12 V
+5 V
+17 V
Gate drive
Servomotor
Gate drive protector
Temperature sensor
Current sensor
Dynamic brake circuit
+ 12 V
U
V
W
ASIC
(PWM control, etc.)
M
ENC
CN2
Analog voltage converter
CN5
CN1
Analog monitor output
Encoder output pulse
Panel display
CN3
Digital operator
CN7
Personal computer
CPU
(Position/speed calculation, etc.)
I/O
CN6A
I/F
CN8
CN6B
Signal for safety function
I/O signal
MECHATROLINKII communications
1.4 SERVOPACK Internal Block Diagrams
1.4.3
Three-phase 200 V, SGDV-R70A15
, -R90A15
, -1R6A15
Models
L1 Varistor
L2
Main circuit power supply
L3
1
2
Voltage sensor
L1C Varistor
Control power supply
L2C
B1/ B2 B3
Fan
∗
+
–
Control power supply
Relay drive
CHARGE
+17 V
+5 V
±
12 V
Servomotor
+
–
Voltage sensor
Gate drive
Temperature sensor
Gate drive protector
Current sensor
+ 12 V
U
V
W
Dynamic brake circuit
ASIC
(PWM control, etc.)
M
ENC
CN2
Analog voltage converter
CN5
CN1
Analog monitor output
Encoder output pulse
Panel display
CPU
(Position/speed calculation, etc.)
CN3 CN7
Digital operator Personal computer
∗ The following SERVOPACKs do not have cooling fans: SGDV B
1.4.4
Three-phase 200 V, SGDV-2R8A15
Model
I/O
CN6A
I/F
CN8
CN6B
Signal for safety function
I/O signal
MECHATROLINKII communications
B1/ B2 B3
Fan
∗
Main circuit power supply
L1 Varistor
L2
L3
1
2
Voltage sensor
L1C
Varistor
Control power supply
L2C
Relay drive
+
–
Control power supply
CHARGE
+17 V
+5 V
±
12 V
Servomotor
+
–
Voltage sensor
Gate drive
Temperature sensor overcurrent protector
Current sensor
+ 12 V
U
V
W
Dynamic brake circuit
ASIC
(PWM control, etc.)
M
ENC
CN2
Analog voltage converter
CN5
CN1
Analog monitor output
Encoder output pulse
Panel display
CPU
(Position/speed calculation, etc.)
CN3 CN7
Digital operator Personal computer
∗ The following SERVOPACKs do not have cooling fans: SGDV B
I/O
CN6A
I/F
CN8
CN6B
Signal for safety function
I/O signal
MECHATROLINKII communications
1
1-9
1-10
1 Outline
1.4.5 Three-phase 200 V, SGDV-3R8A15A, -5R5A15A, -7R6A15A Models
1.4.5
Three-phase 200 V, SGDV-3R8A15A, -5R5A15A, -7R6A15A Models
L1
Varistor
Main circuit power supply
L2
L3
1
2
L1C
Varistor
Control power supply
L2C
Voltage sensor
Relay drive
CHARGE
+
–
Control power supply
B1/ B2 B3
Fan
+
–
+17 V
+5 V
±
12 V
Servomotor
Voltage sensor
Gate drive
Temperature sensor
Gate drive protector
Current sensor
± 12 V U
V
W
Dynamic brake circuit
ASIC
(PWM control, etc.)
M
ENC
CN2
Analog voltage converter
CN5
CN1
Analog monitor output
Encoder output pulse
Panel display
CN3
Digital operator
CN7
Personal computer
CPU
(Position/speed calculation, etc.)
I/O
CN6A
I/F
CN8
CN6B
Signal for safety function
I/O signal
MECHATROLINKII communications
1.4.6
Three-phase 200 V, SGDV-120A15A Model
L1 Varistor
Main circuit power supply
L2
L3
1
2
Voltage sensor
L1C
Varistor
Control power supply
L2C
Relay drive
CHARGE
+
–
+
–
Control power supply
+15 V
×
4
+5 V
±
12 V
Voltage sensor
B1/ B2 B3 Fan
Servomotor
Overheat protector, overcurrent protector
Gate drive
Current sensor
± 12 V
U
V
W
Dynamic brake circuit
ASIC
(PWM control, etc.)
M
ENC
CN2
Analog voltage converter
CN5
CN1
Analog monitor output
Encoder output pulse
Panel display
CN3
Digital operator
CN7
Personal computer
CPU
(Position/speed calculation, etc.)
I/O
CN6A
I/F
CN8
CN6B
Signal for safety function
I/O signal
MECHATROLINKII communications
1.4 SERVOPACK Internal Block Diagrams
1.4.7
Three-phase 200 V, SGDV-180A15A, -200A15A Models
L1 Varistor
Main circuit power supply
L2
L3
1
2
Voltage sensor
L1C Varistor
Control power supply
L2C
B1/ B2 B3
Fan 1 Fan 2
CHARGE
Relay drive
+
–
+
–
Control power supply
+15 V × 4
+5 V
±
12 V
Voltage sensor
Overheat protector, overcurrent protector
Gate drive
ASIC
(PWM control, etc.)
Servomotor
± 12 V ± 12 V U
V
W
Dynamic brake circuit
Current sensor
M
ENC
CN2
Analog voltage converter
CN5
CN1
Analog monitor output
Encoder output pulse
Panel display
CN3
Digital operator
CN7
Personal computer
CPU
(Position/speed calculation, etc.)
I/O
CN6A
I/F
CN8
CN6B
Signal for safety function
I/O signal
MECHATROLINKII communications
1.4.8
Three-phase 200 V, SGDV-330A15A Model
L1 Varistor
Main circuit power supply
L2
L3
1
2
Voltage sensor
L1C
Varistor
Control power supply
L2C
B1/ B2 B3
Fan 1 Fan 2
Thyristor drive
CHARGE
+
–
Control power supply
+15 V
×
4
+5 V
± 12 V
+
–
Voltage sensor
Servomotor
Overheat protector, overcurrent protector
± 12 V ± 12 V U
V
W
Dynamic brake circuit
Gate drive
Temperature sensor
Current sensor
ASIC
(PWM control, etc.)
M
ENC
CN2
Analog voltage converter
CN5
CN1
Analog monitor output
Encoder output pulse
1
Panel display
CN3
Digital operator
CN7
Personal computer
CPU
(Position/speed calculation, etc.)
I/O
CN6A
I/F
CN8
CN6B
Signal for safety function
I/O signal
MECHATROLINKII communications
1-11
1-12
1 Outline
1.4.9 Three-phase 200 V, SGDV-550A15A Models
1.4.9
Three-phase 200 V, SGDV-550A15A Models
L1 Varistor
Main circuit power supply
L2
L3
L1C Varistor
Control power supply
L2C
Voltage sensor
B1/ B2 Fan 1 Fan 2 Fan 3
Thyristor drive
CHARGE
+
–
+
–
Control power supply
+15 V
×
4
+5 V
± 12 V
Voltage sensor
Overheat protector, overcurrent protector
± 12 V ± 12 V ± 12 V
U
V
W
Servomotor
M
Dynamic brake circuit
Gate drive
Temperature sensor
Current sensor
ENC
ASIC
(PWM control, etc.)
CN2
Analog voltage converter
CN5
CN1
Analog monitor output
Encoder output pulse
Panel display
CN3
Digital operator
CN7
Personal computer
CPU
(Position/speed calculation, etc.)
I/O
CN6A
I/F
CN8
CN6B
Signal for safety function
I/O signal
MECHATROLINKII communications
1.4.10
Three-phase 400 V, SGDV-1R9D15A, -3R5D15A, -5R4D15A Models
L1 Varistor
Main circuit power supply
L2
L3
1
2
Control power supply
(The 24 VDC power supply is not included.)
+24 V
0 V
Voltage sensor
Relay drive
+
–
+
–
+
–
Control power supply
+15 V
×
4
+5 V
± 12 V
CHARGE
Voltage sensor
B1/ B2 B3
Fan
Overheat protector, overcurrent protector
Gate drive
ASIC
(PWM control, etc.)
Servomotor
± 12 V U
V
W
Dynamic brake circuit
M
Current sensor
ENC
CN2
Analog voltage converter
CN5
CN1
Analog monitor output
Encoder output pulse
Panel display
CN3
Digital operator
CN7
Personal computer
CPU
(Position/speed calculation, etc.)
I/O
CN6A
I/F
CN8
CN6B
Signal for safety function
I/O signal
MECHATROLINKII communications
1.4 SERVOPACK Internal Block Diagrams
1.4.11
Three-phase 400 V, SGDV-8R4D15A, -120D15A Models
B1/ B2 B3 Fan 1 Fan 2
Servomotor
L1 Varistor
Main circuit power supply
L2
L3
1
2
Relay drive
+
–
+
–
CHARGE
Voltage sensor
Overheat protector, overcurrent protector
± 12 V ± 12 V U
V
W
Dynamic brake circuit
Gate drive
Current sensor
M
Voltage sensor
ENC
+24 V
Control power supply
(The 24 VDC power supply is not included.)
0 V
+
–
Control power supply
+15 V
×
4
+5 V
±
12 V
ASIC
(PWM control, etc.)
CN2
Analog voltage converter
CN5
CN1
Analog monitor output
Encoder output pulse
Panel display
CN3
Digital operator
CN7
Personal computer
CPU
(Position/speed calculation, etc.)
I/O
CN6A
I/F
CN8
CN6B
Signal for safety function
I/O signal
MECHATROLINKII communications
1.4.12
Three-phase 400 V, SGDV-170D15A Model
L1 Varistor
Main circuit power supply
L2
L3
1
2
+24 V
Control power supply
(The 24 VDC power supply is not included.)
0 V
Voltage sensor
B1/ B2 B3
Fan
Relay drive
+
–
Control power supply
+
–
+
– CHARGE
+15 V
×
4
+5 V
±
12 V
Voltage sensor
Servomotor
Overheat protector, overcurrent protector
Gate drive
Current sensor
± 12 V U
V
W
Dynamic brake circuit
ASIC
(PWM control, etc.)
M
ENC
CN2
Analog voltage converter
CN5
CN1
Analog monitor output
Encoder output pulse
Panel display
CN3
Digital operator
CN7
Personal computer
CPU
(Position/speed calculation, etc.)
I/O
CN6A
I/F
CN8
CN6B
Signal for safety function
I/O signal
MECHATROLINKII communications
1
1-13
1-14
1 Outline
1.4.13 Three-phase 400 V, SGDV-260D15A Model
1.4.13
Three-phase 400 V, SGDV-260D15A Model
L1 Varistor
Main circuit power supply
L2
L3
1
2
+24 V
Control power supply
(The 24 VDC power supply is not included.)
0 V
Voltage sensor
B1/ B2
Fan 1 Fan 2 Fan 3
Relay drive
+
–
Control power supply
+
–
+
–
CHARGE
+15 V × 4
+5 V
±
12 V
Voltage sensor
Overheat protector, overcurrent protector
Gate drive
+
24 V
+
24 V
+
24 V
U
V
W
Servomotor
M
Dynamic brake circuit
Current sensor
ENC
ASIC
(PWM control, etc.)
CN2
Analog voltage converter
CN5
CN1
Analog monitor output
Encoder output pulse
Panel display
CN3
Digital operator
CN7
Personal computer
CPU
(Position/speed calculation, etc.)
I/O
CN6A
I/F
CN8
CN6B
Signal for safety function
I/O signal
MECHATROLINKII communications
1.5 Examples of Servo System Configurations
1.5
Examples of Servo System Configurations
This section describes examples of basic servo system configuration.
1.5.1
Connecting to SGDV-
F15A SERVOPACK
Power supply
Single-phase 100 VAC
R T
Molded-case circuit breaker
(MCCB)
Protects the power line by shutting the circuit OFF when overcurrent is detected.
Noise filter
Eliminates external noise from the power line.
Connect to the
MECHATROLINKII
SGDVF15A
SERVOPACK
Digital operator
Magnetic contactor
Turns the servo
ON and OFF.
Install a surge absorber.
Connection cable for digital operator
Connection cable for personal computer
I/O signal cable
Personal computer
Host controller
Regenerative resistor *
Servomotor main circuit cable
Connection cable for serial converter unit
Serial converter unit
When not using the safety function, use the SERVOPACK with the safety function’s jumper connector inserted.
When using the safety function, use the safety connection cable.
Safety connection cable
Safety function devices
Connection cable for linear scale
Linear scale
(not included)
Connection cable for hall sensor
Servomotor with core
∗ Before connecting an external regenerative resistor to the SERVOPACK, refer to 3.7 Connecting Regenerative Resistors .
1
1-15
1-16
1 Outline
1.5.2 Connecting to SGDV A15 SERVOPACK
1.5.2
Connecting to SGDV-
A15
SERVOPACK
(1) Using a Three-phase, 200-V Power Supply
Power supply
Three-phase 200 VAC
R S T
Molded-case circuit breaker
(MCCB)
Protects the power line by shutting the circuit OFF when overcurrent is detected.
Noise filter
Eliminates external noise from the power line.
SGDVA15
SERVOPACK
Magnetic contactor
Turns the servo
ON and OFF.
Install a surge absorber.
Connect to the
MECHATROLINKII
Connection cable for digital operator
Digital operator
Personal computer
Connection cable for personal computer
I/O signal cable
Host controller
Regenerative resistor
∗
Servomotor main circuit cable
Connection cable for serial converter unit
Serial converter unit
When not using the safety function, use the SERVOPACK with the safety function’s jumper connector inserted.
When using the safety function, use the safety connection cable.
Safety connection cable
Safety function devices
Connection cable for linear scale
Linear scale
(not included)
Connection cable for hall sensor
Servomotor with core
∗ Before connecting an external regenerative resistor to the SERVOPACK, refer to 3.7 Connecting Regenerative Resistors .
1.5 Examples of Servo System Configurations
(2) Using a Single-phase, 200-V Power Supply
The Σ -V Series 200 V SERVOPACK generally specifies a three-phase power input but some models can be used with a single-phase 200 V power supply. Refer to 3.1.3 Using the SERVOPACK with Single-phase, 200 V
Power Input for details.
Power supply
Single-phase 200 VAC
R T
Molded-case circuit breaker
(MCCB)
Protects the power line by shutting the circuit OFF when overcurrent is detected.
Connect to the
MECHATROLINKII
Noise filter
Eliminates external noise from the power line.
SGDVA15
SERVOPACK
Digital operator
Magnetic contactor
Turns the servo
ON and OFF.
Install a surge absorber.
Connection cable for digital operator
Connection cable for personal computer
I/O signal cable
Host controller
Personal computer
Regenerative resistor
∗
Connection cable for serial converter unit
Serial converter unit
When not using the safety function, use the SERVOPACK with the safety function’s jumper connector inserted.
When using the safety function, use the safety connection cable.
Safety connection cable
Safety function devices
Servomotor main circuit cable
Connection cable for linear scale
Linear scale
(not included)
Connection cable for hall sensor
1
Servomotor with core
∗ Before connecting an external regenerative resistor to the SERVOPACK, refer to 3.7 Connecting Regenerative Resistors .
1-17
1-18
1 Outline
1.5.3 Connecting to SGDV D15A SERVOPACK
1.5.3
Connecting to SGDV-
D15A SERVOPACK
Power supply
Three-phase 400 VAC
R S T
Molded-case circuit breaker
(MCCB)
Protects the power line by shutting the circuit OFF when overcurrent is detected.
Noise filter
Eliminates external noise from the power line.
SGDVD15A
SERVOPACK
Magnetic contactor
Turns the servo
ON and OFF.
Install a surge absorber.
Connection cable for digital operator
Personal computer
Connection cable for personal computer
I/O signal cable
Host controller
DC power supply (24 VDC)
∗
1
Connect to the MECHATROLINKII
Digital operator
Regenerative resistor
∗
2
Connection cable for serial converter unit
Serial converter unit
When not using the safety function, use the SERVOPACK with the safety function’s jumper connector inserted.
When using the safety function, use the safety connection cable.
Safety connection cable
Safety function devices
Servomotor main circuit cable
Connection cable for hall sensor
Connection cable for linear scale
Linear scale
(not included)
Servomotor with core
∗1.
Use a 24-VDC power supply with double insulation or reinforced insulation. (The power supply is not included.)
∗2.
Before connecting an external regenerative resistor to the SERVOPACK, refer to 3.7 Connecting Regenerative Resistors .
1.6 SERVOPACK Model Designation
1.6
SERVOPACK Model Designation
This section shows SERVOPACK model designation .
SGDV –
1st + 2nd +
3rd digits
4th digit
5th + 6th
digits
7th digit
2R8 A 15 A
8th + 9th +
10th digits
000
11th + 12th digits
00
13th digit
0
SGDV
Series
Σ -V Series
A
B
7th digit: Design
Revision Order
Other than below
• SGDV-R70A
• SGDV-R90A
• SGDV-1R6A
• SGDV-2R8A
1st + 2nd + 3rd digits: Current
Voltage Code
R70
Max. Allowable
Motor Capacity
(kW)
0.05
R90
100 V
2R1
0.1
0.2
200 V
2R8
R70
*1
R90
*1
1R6 *1
2R8
*1
3R8
5R5
*1
7R6
120
180
200
0.4
0.05
0.1
0.2
0.4
0.5
0.75
1
1.5
2
330
550
*2
1R9
3R5
3
5
7.5
0.5
400 V
5R4
8R4
120
170
260 *2
1
1.5
2
3
5
7.5
4th digit: Voltage
Code
F
A
D
Voltage
100 V
200 V
400 V
13th digit: Parameter
0
Specification
Code Specification
Standard
5th + 6th digits: Interface Specifications
Code
01
05
11
15
21
25
Interface
Analog voltage and pulse train reference, rotational servomotor
Analog voltage and pulse train reference, linear servomotor
MECHATROLINK-II communications reference, rotational servomotor
MECHATROLINK-II communications reference, linear servomotor
MECHATROLINK-III communications reference, rotational servomotor
MECHATROLINK-III communications reference, linear servomotor
11th + 12th digits: Software
Code
00
Specification
Specification
Standard
8th + 9th + 10th digits: Hardware Specifications
Code Specifications
000 Base-mounted (standard)
001 Rack-mounted
*2
002 Varnished
003 Rack-mounted *2 and Varnished
020 Dynamic brake (DB) *3
∗1.
These amplifiers can be powered with single or three-phase.
∗2.
SGDV-550A and -260D are duct-ventilated types.
∗3.
A resistor for the dynamic brake is not included. An external resistor for the dynamic brake can only be used with
400-V SERVOPACKs.
Note: If the option codes digits 8 to 13 are all zeros, they are omitted.
1
1-19
1-20
1 Outline
1.7.1 SERVOPACK Inspection
1.7
Servo Drive Maintenance and Inspection
This section describes the inspection and maintenance of a servo drive.
1.7.1
SERVOPACK Inspection
For inspection and maintenance of the SERVOPACK, follow the inspection procedures in the following table at least once every year. Other routine inspections are not required.
Exterior
Item
Loose Screws
Frequency
At least once a year
Procedure
Check for dust, dirt, and oil on the surfaces.
Check for loose terminal block and connector screws.
Comments
Clean with a cloth or compressed air.
Tighten any loose screws.
1.7.2
SERVOPACK’s Parts Replacement Schedule
The following electric or electronic parts are subject to mechanical wear or deterioration over time. To avoid failure, replace these parts at the frequency indicated.
Refer to the standard replacement period in the following table and contact your Yaskawa representative.
After an examination of the part in question, we will determine whether the parts should be replaced or not.
The parameters of any SERVOPACKs overhauled by Yaskawa are reset to the factory settings before shipping. Be sure to confirm that the parameters are properly set before starting operation.
Part
Cooling Fan
Smoothing Capacitor
Other Aluminum Electrolytic Capacitor
Relays
Fuses
Standard Replacement Period
4 to 5 years
7 to 8 years
5 years
–
10 years
Note: The standard replacement period is given for usage under the following operating conditions.
• Surrounding air temperature: Annual average of 30°C
• Load factor: 80% max.
• Operation rate: 20 hours/day max.
1.7 Servo Drive Maintenance and Inspection
1.7.3
Servomotor Inspection
The AC servomotor is brushless and simple daily inspection is sufficient. Use the inspection frequencies given in the following table as a guide. Determine the most appropriate inspection frequency from the actual usage conditions and the environment.
Inspected Item
Vibration and
Noise Check
Appearance
Inspection
Insulation
Resistance Measurement
Oil Seal
Replacement
Overhaul
Inspection Frequency
Daily or Interval
Depends on amount of dirt.
Inspection or Maintenance
Procedure
Inspect by touching and listening to the servomotor.
Clean with a cloth or compressed air.
At least once a year
At least once every 5,000 hours
At least once every 5 years or 20,000 hours
Disconnect the servomotor from the SERVOPACK and measure the insulation resistance with a
500 V insulation resistance meter.* The servomotor is normal if the resistance is higher than 10
M Ω .
Contact your Yaskawa representative.
Contact your Yaskawa representative.
−
Remark
There should be no more vibration or noise than normal.
• If the resistance is 10 M resentative.
Ω or lower, contact your Yaskawa rep-
• Do not measure the insulation resistance of the encoder or perform a withstand test on it.
Only necessary if the servomotor has an oil seal.
−
∗ Measure the insulation resistance between the U, V, or W phase on the servomotor’s power line and the frame ground.
1
1-21
2
Panel Display and
Operation of Digital Operator
2.1 Panel Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.1 Status Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.2 Alarm and Warning Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.3 Hard Wire Base Block Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.4 Overtravel Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.2 Operation of Digital Operator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.3 Utility Functions (Fn ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.4 Parameters (Pn ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
2.4.1 Parameter Classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
2.4.2 Notation for Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
2.4.3 Setting Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2.5 Monitor Displays (Un ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
2
2-1
2-2
2 Panel Display and Operation of Digital Operator
2.1.1 Status Display
2.1
Panel Display
You can use the panel display on the SERVOPACK to check the status of the servo drive.
Also, if an alarm or warning occurs, its alarm or warning number is displayed.
2.1.1
Status Display
The display shows the following status.
Display Meaning
Movement Detection (/TGON)
Lights if motor speed exceeds the value set in Pn581. (Factory setting: 20 mm/s)
Baseblock
Lights for baseblock (Servomotor power OFF).
Reference Input
Lights when a reference is being input.
CONNECT
Lights during connection.
2.1.2
Alarm and Warning Display
If an alarm or warning occurs, the display will change in the following order.
Example: Alarm A.E60
Status
Display
Unlit Unlit Unlit Unlit Unlit
2.1.3
Hard Wire Base Block Display
If a hard wire base block (HWBB) occurs, the display will change in the following order.
Status
Display
Unlit Unlit Unlit Unlit
2.1.4
Overtravel Display
If overtraveling occurs, the display will change in the following order.
1 Overtravel at forward direction (P-OT)
Current status
2 Overtravel at reverse direction (N-OT)
Current status
3 Overtravel at forward/reverse direction
Current status
2.2 Operation of Digital Operator
2.2
Operation of Digital Operator
Operation examples of utility functions (Fn ), parameters (Pn ) and monitor displays (Un ) when using a digital operator are described in this chapter.
Operations can be also performed with SigmaWin+.
For more information on the usage of the digital operator, refer to
Digital Operator (No.: SIEP S800000 55).
Σ -V Series USER’S MANUAL Operation of
2.3
Utility Functions (Fn
)
The utility functions are related to the setup and adjustment of the SERVOPACK.
The digital operator shows numbers beginning with Fn.
The following table outlines the procedures necessary for an origin search (Fn003).
Step
1
Display after Operation
B B − F U N C T I O N −
F n 0 0 2 : J O G
F n 0 0 3 : Z − S e a r c h
F n 0 0 4 : P r o g r a m J O G
F n 0 0 5 : P r m I n i t
Keys Operation
Press the ity function.
Key to view the main menu for the util-
Use the or select Fn003.
Key to move through the list and
2
B B − Z − S e a r c h −
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 3 = 0 0 0 0 0 0 0 0 7 7 4
U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0
Press the Key. The display changes to the Fn003 execution display.
3
4
5
R U N − Z − S e a r c h −
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 3 = 0 0 0 0 0 0 0 0 7 7 4
U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0
R U N − C o m p l e t e −
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 3 = 0 0 0 0 0 0 0 0 0 0 0
U n 0 0 D = 0 0 0 0 0 0 0 1 D 5 8
B B − Z − S e a r c h −
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 3 = 0 0 0 0 0 0 0 0 0 0 0
U n 0 0 D = 0 0 0 0 0 0 0 1 D 5 8
Press the Key.
The status display changes from "BB" to "RUN", and the servomotor power turns ON.
Note: If the servomotor is already at the zero position,
"-Complete-" is displayed.
Pressing the Key will run the servomotor in the forward direction. Pressing the Key will run the servomotor in the reverse direction. The movement direction of the servomotor changes according to the setting of Pn000.0 as shown in the following table.
Parameter key key n.
n.
0
1
Linear scale counting up
Linear scale counting down
Pn000
Linear scale counting down
Linear scale counting up
Note: Forward movement is the linear scale counting up direction. For details, refer to 4.3.1 Servomotor Movement Direction .
Press the or Key until the servomotor stops.
If the origin search completed normally, "-Complete-" is displayed on the right top on the screen.
When the origin search is completed, press the
Key.
The status display changes from "RUN" to "BB", and the servomotor turns OFF. The display "-Complete-" changes to "-Z-Search-."
6
B B − F U N C T I O N −
F n 0 0 2 : J O G
F n 0 0 3 : Z
−
S e a r c h
F n 0 0 4 : P r o g r a m J O G
F n 0 0 5 : P r m I n i t
Press the Key.
The display returns to the main menu of the utility function.
7 To enable the change in the setting, turn the power OFF and ON again.
2
2-3
2-4
2 Panel Display and Operation of Digital Operator
2.4.1 Parameter Classification
2.4
Parameters (Pn
)
This section describes the classifications, methods of notation, and settings for parameters given in this manual.
2.4.1
Parameter Classification
Parameters of the Σ -V Series SERVOPACK are classified into two types of parameters. One type of parameters is required for setting up the basic conditions for operation and the other type is required for tuning parameters that are required to adjust servomotor characteristics.
Classification
Setup Parameters
Tuning Parameters
Meaning
Parameters required for setup.
Parameters for tuning control gain and other parameters.
Display Method
Always displayed (Factory setting: Pn00B.0 = 0)
Set Pn00B.0 to 1.
Setting Method
Set each parameter individually.
There is no need to set each parameter individually.
There are two types of notation used for parameters, one for parameter that requires a value setting (parameter for numeric settings) and one for parameter that requires the selection of a function (parameter for selecting functions).
The notation and settings for both types of parameters are described next.
2.4.2
Notation for Parameters
(1) Parameters for Numeric Settings
The control methods for which the parameters applies.
Speed : Speed control Position : Position control Force : Force control
Pn311
Vibration Detection Sensitivity
Setting Range
50 to 500
Setting Unit
1%
Speed
Factory Setting
100
Position Force
When Enabled
Immediately
Parameter number
Indicates the setting range for the parameter.
Indicates the minimum setting unit for the parameter.
Indicates the parameter setting before shipment.
Indicates when a change to the parameter will be effective.
Classification
Tuning
Indicates the parameter classification.
(2) Parameters for Selecting Functions
Pn002
Parameter Meaning n.
0
[Factory setting]
Uses the absolute linear scale as an absolute linear scale.
n.
1
Uses the absolute linear scale as an incremental linear scale.
Parameter number
When Enabled Classification
After restart
The notation “n.
” indicates a parameter for selecting functions. Each corresponds to the setting value of that digit. The notation shown here means that the third digit is 1.
This section explains the selections for the function.
Setup
2.4 Parameters (Pn )
• Notation Example
Digital Operator Display (Display Example for Pn002)
㨚㧜㧜㧜㧜
1st digit
2nd digit
Notation
Digit Notation
Meaning
Pn002.0
Pn002.1
Indicates the value for the
1st digit of parameter Pn002.
Indicates the value for the
2nd digit of parameter Pn002.
3rd digit
4th digit
Pn002.2
Pn002.3
Indicates the value for the
3rd digit of parameter Pn002.
Indicates the value for the
4th digit of parameter Pn002.
Notation
Setting Notation
Meaning
Pn002.0 = x or n.
x
Indicates that the value for the
1st digit of parameter Pn002 is x.
Pn002.1 = x or n.
x
Indicates that the value for the
2nd digit of parameter Pn002 is x.
Pn002.2 = x or n.
x
Indicates that the value for the
3rd digit of parameter Pn002 is x.
Pn002.3 = x or n.x
Indicates that the value for the
4th digit of parameter Pn002 is x.
2.4.3
Setting Parameters
(1) How to Make Numeric Settings Using Parameters
The following example shows how to change the setting of parameter Pn383 (JOG speed) to 1000 mm/s.
Keys Operation Step
1
Display after Operation
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㨁㨚㧜㧜㧜㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
2
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㨁㨚㧜㧜㧜㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
3
4
5
6
7
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧜㧜㧜㧩㨚㧜㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧜㧜㧜㧩㨚㧜㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜㨜㨡㨘㨟㨑
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧟㧤㧟㧩㧜㧜㧡㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧟㧤㧟㧩㧜㧜㧡㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧟㧤㧟㧩㧜㧜㧡㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
8
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧟㧤㧟㧩㧜㧝㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
Press the Key to select the main menu of parameters and monitor displays.
Press the or Key to move the cursor to "Un."
Press the or Key to change "Un" to "Pn."
Press the Key to move the cursor to the column on the right of "Pn."
Press the arrow keys to display "Pn383".
To move the cursor to different columns: ,
Key
To change the settings: , Key
Press the Key to move the cursor to the one’s place of Pn383.
Press the Key twice to move the cursor to the hundred’s place of Pn383.
Press the Key five times to change the setting to
"1000."
2
2-5
2-6
2 Panel Display and Operation of Digital Operator
2.4.3 Setting Parameters
Step
9
Display after Operation
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧟㧤㧟㧩㧜㧝㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
Keys Operation
Press the Key to write the settings.
(cont’d)
(2) How to Select Functions Using Parameters
The following example shows how to set the function section for insufficient voltage of the application function select switch 8 (Pn008) to 1 "detects warning and limits force by host controller."
Keys Operation Step
1
2
3
4
5
6
7
8
9
Display after Operation
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㨁㨚㧜㧜㧜㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㨁㨚㧜㧜㧜㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧜㧜㧜㧩㨚㧜㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧜㧜㧜㧩㨚㧜㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧜㧜㧤㧩㨚㧠㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧜㧜㧤㧩㨚㧠㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧜㧜㧤㧩㨚㧠㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧜㧜㧤㧩㨚 㧠㧜㧝㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
Press the Key to select the main menu of parameters and monitor displays.
Press the or Key to move the cursor to
"Un."
Press the
Press the to "1."
or Key to change "Un" to "Pn."
Press the Key three times to move the cursor to the column on the right of "Pn."
Press the Key to display "Pn008."
Press the Key to move the cursor to "Pn008.0."
Press the Key once to move the cursor to
"Pn008.1."
Key to change the setting of "Pn008.1"
Press the Key to write the settings.
2.5 Monitor Displays (Un )
2.5
Monitor Displays (Un
)
The monitor displays can be used for monitoring the reference values, I/O signal status, and SERVOPACK internal status.
For details, refer to 7.2 Viewing Monitor Displays .
The digital operator shows numbers beginning with Un.
The following four settings are the factory settings.
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㨁㨚㧜㧜㧜㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
Shows the setting of Un000 (motor moving speed) as 0 mm/s.
2
2-7
3
Wiring and Connection
3.1 Main Circuit Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3.1.1 Main Circuit Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3.1.2 Using a Standard Power Supply
(Single-phase 100 V, Three-phase 200 V, or Three-phase 400 V) . . . . . . . . . . . . . . . 3-3
3.1.3 Using the SERVOPACK with Single-phase, 200 V Power Input . . . . . . . . . . . . . . . . 3-11
3.1.4 Using the SERVOPACK with a DC Power Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14
3.1.5 Using More Than One SERVOPACK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18
3.1.6 General Precautions for Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19
3.2 I/O Signal Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-20
3.2.1 I/O Signal (CN1) Names and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-20
3.2.2 Safety Function Signal (CN8) Names and Functions . . . . . . . . . . . . . . . . . . . . . . . . 3-21
3.2.3 Example of I/O Signal Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-22
3.3 I/O Signal Allocations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23
3.3.1 Input Signal Allocations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23
3.3.2 Output Signal Allocations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-25
3.4 Examples of Connection to Host Controller . . . . . . . . . . . . . . . . . . . . . . 3-26
3.4.1 Sequence Input Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-26
3.4.2 Sequence Output Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-27
3.5 Wiring MECHATROLINKII Communications . . . . . . . . . . . . . . . . . . . . . 3-29
3.6 Linear Scale Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-30
3.6.1 Linear Scale Signal (CN2) Names and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-30
3.6.2 Serial Converter Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-30
3.6.3 Linear Scale Connection Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-33
3.7 Connecting Regenerative Resistors . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-37
3.7.1 Connecting Regenerative Resistors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-37
3.7.2 Setting Regenerative Resistor Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-39
3.8 Noise Control and Measures for Harmonic Suppression . . . . . . . . . . . . 3-40
3.8.1 Wiring for Noise Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-40
3.8.2 Precautions on Connecting Noise Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-42
3.8.3 Connecting a Reactor for Harmonic Suppression . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-43
3
3-1
3 Wiring and Connection
3.1.1 Main Circuit Terminals
3.1
Main Circuit Wiring
The names and specifications of the main circuit terminals are given below.
Also this section describes the general precautions for wiring and precautions under special environments.
3.1.1
Main Circuit Terminals
3-2
: Main circuit terminals
Terminal
Symbols
L1, L2
L1, L2, L3
L1C, L2C
24V, 0V
B1/ , B2
*1
1, 2
*2
Name Model SGDV
Main circuit power input terminals
Control power input terminals
F
A
D
F
A
D
External regenerative resistor connection terminals
R70F, R90F, 2R1F,
2R8F, R70A, R90A,
1R6A, 2R8A
3R8A, 5R5A, 7R6A,
120A, 180A, 200A,
330A, 1R9D, 3R5D,
5R4D, 8R4D, 120D,
170D
550A, 260D
DC reactor connection terminal for power supply harmonic suppression
A
D
Specification
Single-phase 100 to 115 V, +10 to -15%, 50/60 Hz
Three-phase 200 to 230 V, +10 to -15%, 50/60 Hz
Three-phase 380 to 480 V, +10 to -15%, 50/60 Hz
Single-phase 100 to 115 V, +10 to -15%, 50/60 Hz
Single-phase 200 to 230 V, +10 to -15%, 50/60 Hz
24 VDC, ± 15%
If the regenerative capacity is insufficient, connect an external regenerative resistor between B1/ and
B2.
Note: The external regenerative resistor is not included.
If the internal regenerative resistor is insufficient, remove the lead or shorting bar between B2 and B3 and connect an external regenerative resistor between B1/ and B2.
Note: The external regenerative resistor is not included.
Connect a regenerative resistor unit between B1/ and B2.
Note: The regenerative resistor unit is not included.
If a countermeasure against power supply harmonic waves is needed, connect a DC reactor between 1 and 2.
3.1 Main Circuit Wiring
(cont’d)
Terminal
Symbols
Name Model SGDV Specification
B1/
2 or
U, V, W
Main circuit positive terminal
Main circuit negative terminal
Servomotor connection terminals
Ground terminals
( × 2)
A
D
A
D
Use for connecting the power supply ground terminal and servomotor ground terminal.
Use when DC power supply input is used.
Use for connecting to the servomotor.
∗1.
Do not short-circuit between B1/ and B2. It may damage the SERVOPACK.
∗2.
The DC reactor connection terminals are short-circuited when the SERVOPACK is shipped from the factory: 1 and
2.
3.1.2
Using a Standard Power Supply
(Single-phase 100 V, Three-phase 200 V, or Three-phase 400 V)
(1) Wire Types
Use the following type of wire for main circuit.
Symbol
IV
HIV
Cable Type
Name
600 V grade polyvinyl chloride insulated wire
600 V grade heat-resistant polyvinyl chloride insulated wire
Allowable Conductor Temperature ° C
60
75
The following table shows the wire sizes and allowable currents for three wires. Use wires with specifications equal to or less than those shown in the table.
• 600 V grade heat-resistant polyvinyl chloride insulated wire (HIV)
AWG Size
14
12
10
8
6
4
20
19
18
16
Nominal
Cross
Section Area
(mm
2
)
0.5
0.75
0.9
1.25
2.0
3.5
5.5
8.0
14.0
22.0
Configuration
(Number of
Wires/mm)
19/0.18
30/0.18
37/0.18
50/0.18
7/0.6
7/0.8
7/1.0
7/1.2
7/1.6
7/2.0
Conductive
Resistance
( Ω /km)
9.53
5.41
3.47
2.41
39.5
26.0
24.4
15.6
1.35
0.85
Note: The values in the table are for reference only.
Allowable Current at Surrounding Air
Temperature (A)
30 ° C
23
33
43
55
6.6
8.8
9.0
12.0
79
91
40 °
20
29
38
49
C
5.6
7.0
7.7
11.0
70
81
50 ° C
16
24
31
40
4.5
5.5
6.0
8.5
57
66
3
3-3
3-4
3 Wiring and Connection
3.1.2 Using a Standard Power Supply (Single-phase 100 V, Three-phase 200 V, or Three-phase 400 V)
(2) Main Circuit Wires
This section describes the main circuit wires for SERVOPACKs.
• The specified wire sizes are for use when the three lead cables are bundled and when the rated electric current is applied with a surrounding air temperature of 40 ° C.
• Use a wire with a minimum withstand voltage of 600 V for the main circuit.
• If cables are bundled in PVC or metal ducts, take into account the reduction of the allowable current.
• Use a heat-resistant wire under high surrounding air or panel temperatures, where polyvinyl chloride insulated wires will rapidly deteriorate.
Single-phase, 100 V
Terminal
Symbols
Name
L1, L2 Main circuit power input terminals
L1C, L2C Control power input terminals
U, V, W
B1/ , B2
Servomotor connection terminals
External regenerative resistor connection terminals
Ground terminal
Three-phase, 200 V
R70
HIV1.25
SGDV F
R90 2R1
HIV2.0
2R8
HIV1.25
HIV1.25
HIV1.25
HIV2.0 or larger
Terminal
Symbols
Name
L1, L2, L3
Main circuit power input terminals
SGDV A (Unit: mm
2
)
R70 R90 1R6 2R8 3R8 5R5 7R6 120 180 200 330 550
HIV1.25
HIV2.0
HIV3.5
HIV
5.5
HIV
14.0
HIV1.25
U, V, W
B1/ , B2
Servomotor connection terminals
External regenerative resistor connection terminals
Ground terminal
HIV1.25
HIV1.25
HIV2.0
HIV2.0 or larger
HIV
HIV
2.0
5.5
HIV
3.5
HIV
8.0
HIV
5.5
HIV
14.0
HIV
8.0
Three-phase, 400 V
Terminal
Symbols
L1, L2, L3
24V, 0V
U, V, W
B1/ , B2
Name
Main circuit power input terminals
Control power input terminals
Servomotor connection terminals
External regenerative resistor connection terminals
Ground terminal
SGDV D (Unit: mm
2
)
1R9 3R5 5R4 8R4 120 170 260
HIV1.25
HIV2.0
HIV
3.5
HIV
5.5
HIV1.25
HIV1.25
HIV1.25
HIV2.0
HIV
3.5
HIV
2.0
HIV
5.5
HIV
3.5
HIV2.0 or larger
3.1 Main Circuit Wiring
(3) Typical Main Circuit Wiring Examples
Note the following points when designing the power ON sequence.
• The ALM (Servo Alarm) signal is output for up to five seconds when the control power supply is turned ON. Take this into consideration when you design the power ON sequence, and turn ON the main circuit power supply to the SERVO-
PACK when the ALM signal is OFF (alarm cleared).
Power ON
Control power supply
ALM (Servo Alarm)
signal
OFF ON
Alarm
Up to 5.0 s
Alarm cleared.
OFF ON Main circuit power supply
/S-RDY (Servo Ready) signal
Servo ON (SV_ON) command
OFF
OFF
ON
ON
Motor power status Power not supplied.
Power supplied.
<Information>
If the servo ON state cannot be achieved by turning ON the SV_ON command, the /S-RDY signal is not
ON. Check the status of the /S-RDY signal. For details, refer to the 4.8.4 Servo Ready Output Signal (/S-
RDY) .
• Design the power ON sequence so that main circuit power supply is turned OFF when an ALM (Servo Alarm) signal is output.
• Make sure that the power supply specifications of all parts are suitable for the input power supply.
• Allow at least 1 s after the power supply is turned OFF before you turn it ON again.
• When turning ON the control power supply and the main circuit power supply, turn them ON at the same time or turn the main circuit power supply after the control power supply. When turning OFF the power supplies, first turn the power for the main circuit OFF and then turn OFF the control power supply.
The typical main circuit wiring examples are shown below.
WARNING
• Do not touch the power supply terminals after turning OFF the power. High voltage may still remain in the
SERVOPACK, resulting in electric shock. When the voltage is discharged, the charge indicator will turn
OFF. Make sure the charge indicator is OFF before starting wiring or inspections.
3
3-5
3-6
3 Wiring and Connection
3.1.2 Using a Standard Power Supply (Single-phase 100 V, Three-phase 200 V, or Three-phase 400 V)
Single-phase 100 V, SGDV F (SGDV-R70F, -R90F, -2R1F, -2R8F)
3SA
1QF
R T
1FLT
SERVOPACK
SGDVF
2KM
1KM
(For servo alarm display)
1Ry
Servo power supply ON
1PL
Servo power supply OFF 1KM
U
V
W
M
L1
L2
L1C
L2C
ENC
B1/
B2
CN1
3 ALM +
1Ry
+24 V
4 ALM
−
1D 0 V
1KM
1KM 1Ry
1SA
2KM
2SA
1QF: Molded-case circuit breaker
1FLT: Noise filter
1KM: Magnetic contactor (for control power supply)
2KM: Magnetic contactor (for main circuit power supply)
1Ry: Relay
1PL: Indicator lamp
1SA: Surge absorber
2SA: Surge absorber
3SA: Surge absorber
1D: Flywheel diode
Three-phase 200 V, SGDV A
• SGDV-R70A, -R90A, -1R6A, -2R8A, -3R8A, -5R5A, -7R6A, -120A, -180A, -200A, -330A
R S T
SERVOPACK
SGDVA
3SA
1QF
1FLT
2KM
U
V
W
M
1KM
L1
L2
L3
L1C
L2C
ENC
1Ry
(For servo alarm display)
1PL
Servo power supply ON
Servo power supply OFF
1KM
*
B1/
B2
B3
1
2
CN1
3 ALM +
1Ry
+24 V
4 ALM
−
1D 0 V
1KM
1KM 1Ry
1SA
2KM
2SA
1QF: Molded-case circuit breaker
1FLT: Noise filter
1KM: Magnetic contactor (for control power supply)
2KM: Magnetic contactor (for main circuit power supply)
1Ry: Relay
1PL: Indicator lamp
1SA: Surge absorber
2SA: Surge absorber
3SA: Surge absorber
1D: Flywheel diode
∗ For the SGDV-R70A, -R90A, -1R6A, -2R8A, terminals B2 and B3 are not short-circuited. Do not short-circuit these terminals.
3.1 Main Circuit Wiring
• SGDV-550A
3SA
1QF
R S T
1FLT
2KM
1KM
SERVOPACK
SGDVA
U
V
W
M
L1
L2
L3
L1C
L2C
ENC
B1/
B2
CN1
3 ALM +
1Ry
+24 V
4 ALM
−
1D 0 V
1Ry
(For servo alarm display)
1PL
Servo power supply ON
Servo power supply OFF 1KM
1KM
1KM 1Ry
1SA
2KM
Regenerative resistor unit
2SA
1QF: Molded-case circuit breaker
1FLT: Noise filter
1KM: Magnetic contactor (for control power supply)
2KM: Magnetic contactor (for main circuit power supply)
1Ry: Relay
1PL: Indicator lamp
1SA: Surge absorber
2SA: Surge absorber
3SA: Surge absorber
1D: Flywheel diode
Three-phase 400 V, SGDV D
• SGDV-1R9D, -3R5D, -5R4D, -8R4D, -120D, -170D
3SA
1QF
R S T
1FLT
2KM
1KM
DC power supply
24 V
+
−
1Ry
(For servo alarm display)
Servo power supply ON
1PL
Servo power supply OFF
1KM
SERVOPACK
SGDVD
U
V
W
M
L1
L2
L3
24 V
0 V
ENC
B1/
B2
B3
1
2
CN1
3 ALM +
1Ry
+24 V
4 ALM
− 1D 0 V
1KM
1KM 1Ry
1SA
2KM
2SA
1QF: Molded-case circuit breaker
1FLT: Noise filter
1KM: Magnetic contactor (for control power supply)
2KM: Magnetic contactor (for main circuit power supply)
1Ry: Relay
1PL: Indicator lamp
1SA: Surge absorber
2SA: Surge absorber
3SA: Surge absorber
1D: Flywheel diode
3
3-7
3-8
3 Wiring and Connection
3.1.2 Using a Standard Power Supply (Single-phase 100 V, Three-phase 200 V, or Three-phase 400 V)
• SGDV-260D
3SA
1QF
R S T
1FLT
2KM
1KM
DC power supply
(24 V)
+
−
1Ry
(For servo alarm display)
Servo power supply ON
1PL
Servo power supply OFF 1KM
SERVOPACK
SGDVD
U
V
W
M
L1
L2
L3
24 V
0 V
ENC
B1/
B2
CN1
3 ALM +
1Ry
+24 V
1
2
4 ALM
− 1D 0 V
1KM
1KM 1Ry
1SA
2KM
Regenerative resistor unit
2SA
1QF: Molded-case circuit breaker
1FLT: Noise filter
1KM: Magnetic contactor (for control power supply)
2KM: Magnetic contactor (for main circuit power supply)
1Ry: Relay
1PL: Indicator lamp
1SA: Surge absorber
2SA: Surge absorber
3SA: Surge absorber
1D: Flywheel diode
3.1 Main Circuit Wiring
Main
Circuit
Power
Supply
Singlephase,
100 V
Threephase,
200 V
Threephase,
400 V
(4) Power Supply Capacities and Power Losses
The following table shows the SERVOPACK’s power supply capacities and power losses.
7.5
0.5
1.0
1.5
2.0
3.0
5.0
0.75
1.0
1.5
2.0
0.1
0.2
0.4
0.5
3.0
5.0
Maximum
Applicable
Servomotor
Capacity
[kW]
SERVOPACK
Model
SGDV-
0.05 R70F
0.1 R90F
0.2 2R1F
0.4 2R8F
0.05
R70A
R90A
1R6A
2R8A
3R8A
5R5A
7R6A
120A
180A
200A
330A
7.5
550A
1R9D
3R5D
5R4D
8R4D
120D
170D
260D
Power Supply
Capacity per
SERVOPACK
[kVA]
14.6
1.1
2.3
3.5
4.5
7.1
11.7
3.2
4
5.9
7.5
1
1.4
1.6
2.3
1.4
0.2
0.3
0.6
0.2
0.3
0.7
14.4
Output
Current
[Arms]
54.7
1.9
3.5
5.4
8.4
11.9
16.5
11.6
18.5
19.6
32.9
2.8
3.8
5.5
7.6
0.66
0.91
2.1
2.8
0.66
0.91
1.6
25.7
357.8
24.6
46.1
71.3
77.9
108.7
161.1
7.3
13.5
24.0
20.1
43.8
53.6
65.8
111.9
113.8
263.7
Main
Circuit
Power
Loss
[W]
5.4
7.8
14.4
25.6
5.1
218.6
Regenerative
Resistor
Power Loss
[W]
–
–
8
10
16
36
(350)
14
28
*1
Control
Circuit
Power
Loss [W]
17
17
22
27
33
21
25
Total
Power
Loss [W]
36
(180)
*2
24
27
∗1.
The value in parentheses is for the JUSP-RA05-E regenerative resistor unit.
∗2.
The value in parentheses is for the JUSP-RA18-E regenerative resistor unit.
Note 1. SGDV-R70F, -R90F, -2R1F, -2R8F, -R70A, -R90A, -1R6A, and -2R8A SERVOPACKs do not have built-in regenerative resistors. Connect an external regenerative resistor if the regenerative energy exceeds the specified value.
2. SGDV-550A and -260D SERVOPACKs do not have built-in regenerative resistors. Make sure that a regenerative resistor unit or an external regenerative resistor is connected.
Refer to 3.7 Connecting Regenerative Resistors for details.
3. Regenerative resistor power losses are the allowable losses. Take the following actions if this value is exceeded.
• Remove the lead or shorting bar between terminals B2 and B3 on the SERVOPACK main circuit for SGDV-
3R8A, -5R5A, -7R6A, -120A, -180A, -200A, -330A, and 400-V SERVOPACKs.
• Install an external regenerative resistor. Refer to 3.7 Connecting Regenerative Resistors for details.
390.8
59.6
81.1
106.3
130.9
161.7
221.1
41.0
45.1
68.8
78.6
97.8
149.9
161.4
326.7
22.4
24.8
31.4
42.6
22.1
24.3
30.5
245.6
3
3-9
3-10
3 Wiring and Connection
3.1.2 Using a Standard Power Supply (Single-phase 100 V, Three-phase 200 V, or Three-phase 400 V)
(5) How to Select Molded-case Circuit Breaker and Fuse Capacities
The following table shows the SERVOPACK’s current capacities and inrush current.
Use these values as a basis for selecting the molded-case circuit breaker and fuse.
Main
Circuit
Power
Supply
Singlephase,
100 V
Threephase,
200 V
Threephase,
400 V
1.0
1.5
2.0
3.0
3.0
5.0
7.5
0.5
5.0
7.5
Maximum
Applicable
Servomotor
Capacity
[kW]
SERVOPACK
Model
SGDV-
0.05 R70F
0.1 R90F
0.2 2R1F
0.4 2R8F
0.05 R70A
0.1 R90A
0.2 1R6A
0.4 2R8A
0.5
3R8A
0.75 5R5A
1.0
7R6A
1.5
2.0
120A
180A
200A
330A
550A
1R9D
3R5D
5R4D
8R4D
120D
170D
260D
Power Supply
Capacity per
SERVOPACK
[kVA]
3.2
4
5.9
7.5
1
1.4
1.6
2.3
1.4
0.2
0.3
0.6
0.2
0.3
0.7
4.5
7.1
11.7
14.4
14.6
1.1
2.3
3.5
Current Capacity
Main Circuit
[Arms]
Control
Circuit
[Arms]
7.3
9.7
15
25
3.0
3.0
6.0
6.0
10
1.0
1.0
2.0
1.5
2.5
5
5.8
8.6
14.5
21.7
37
1.4
2.9
4.3
0.38
0.2
0.25
0.3
1.2
1.4
1.5
Inrush Current
Main Circuit
[A0-p]
Control
Circuit
[A0-p]
16.5
33
65.5
17
34
57
34
35
70
33
–
Note 1. To comply with the EU low voltage directive, connect a fuse to the input side as protection against accidents caused by short-circuits.
Select fuses or molded-case circuit breakers that are compliant with UL standards.
The table above also provides the net values of current capacity and inrush current. Select a fuse and a moldedcase circuit breaker which meet the breaking characteristics shown below.
• Main circuit, control circuit: No breaking at three times the current values shown in the table for 5 s.
• Inrush current: No breaking at the current values shown in the table for 20 ms.
2. The following restrictions apply to UL standard compliance conditions.
SERVOPACK Model SGDV-
180A, 200A
330A
550A
260D
Restrictions
Available rated current for modeled-case circuit breaker: 40 A or less
• Available rated current for non-time delay fuse: 70 A or less
• Available rated current for time delay fuse: 40 A or less
• Do not use single wires.
• Available rated current for molded-case circuit breaker: 60 A or less
• Available rated current for non-time delay fuse or time delay fuse: 60 A or less
• Available rated current for molded-case circuit breaker: 60 A or less.
• Available rated current for non-time-delay fuse: 60 A or less.
• Available rated current for time delay fuse: 35 A or less
3.1 Main Circuit Wiring
3.1.3
Using the SERVOPACK with Single-phase, 200 V Power Input
Some models of Σ -V series three-phase 200 V power input SERVOPACK can be used also with a single-phase
200 V power supply.
The following models support a single-phase 200-V power input.
SGDV-R70A, -R90A, -1R6A, -2R8A, -5R5A
When using the SERVOPACK with single-phase, 200 V power input, set parameter Pn00B.2 to 1.
(1) Parameter Setting
Single-phase Power Input Selection
Pn00B
Parameter n.
0
[Factory setting] n.
1
Meaning
When
Enabled
Enables use of three-phase power supply for three-phase
SERVOPACK.
Enables use of single-phase power supply for three-phase
SERVOPACK.
After restart
Classification
Setup
WARNING
• If single-phase 200 V is input to a SERVOPACK with a single-phase power input without changing the setting of Pn00B.2 to 1 (single-phase power input), a main circuit cable open phase alarm (A.F10) will be detected.
• SERVOPACK models other than those for single-phase 200-V power input do not support single-phase power input. If a single-phase 200 V is input to the SERVOPACK that do not support single-phase power input, the main circuit cable open phase alarm (A.F10) will be detected.
• When using a single-phase 200 V power supply, the SGDV-R70A, -R90A, -1R6A, -2R8A, or -5R5A SER-
VOPACK may not be able to produce the same servomotor force-speed characteristics as using a threephase 200 V power input. Refer to the diagram of each servomotor force-speed characteristics in
Series Product Catalog (No.: KAEP S800000 42).
Σ V
(2) Main Circuit Power Input Terminals
Connect a single-phase 200 V power supply of the following specifications to L1 and L2 terminals.
The specifications of the power supplies other than the main circuit power supply are the same as for threephase power supply input.
Terminal
Symbols
Name Model SGDV A
L1, L2
Main circuit power input terminals
–
R70, R90, 1R6, 2R8, 5R5
L3
*
∗ Do not use L3 terminal.
(3) Main Circuit Wire for SERVOPACKs
Specifications
Single-phase 200 to 230 V, +10 to -15%,
50/60 Hz
None
Terminal
Symbols
Name
L1, L2
B1/ , B2
Main circuit power input terminals
L1C, L2C Control power input terminals
U, V, W
Servomotor connection terminals
External regenerative resistor connection terminals
Ground terminal
R70
Model SGDV A (Unit: mm
2
)
R90 1R6 2R8
HIV1.25
HIV2.0
5R5
HIV1.25
HIV1.25
HIV2.0
HIV1.25
HIV2.0 or larger
3
3-11
3-12
3 Wiring and Connection
3.1.3 Using the SERVOPACK with Single-phase, 200 V Power Input
(4) Wiring Example with Single-phase 200-V Power Supply Input
SERVOPACK with Single-phase, 200-V Power Supply
Applicable SERVOPACK Model: SGDV-R70A, -R90A, -1R6A, -2R8A, and -5R5A
3SA
1QF
R T
1FLT
2KM
1KM
1Ry
(For servo alarm display)
Servo power supply ON
1PL
Servo power supply OFF
1KM
SERVOPACK
SGDVA
U
V
W
M
L1
L2
L3
L1C
L2C
ENC
B1/
B2
B3
1
2
CN1
3 ALM +
1Ry
+24 V
4 ALM
− 1D 0 V
1KM
1KM 1Ry
1SA
2KM
2SA
1QF: Molded-case circuit breaker
1FLT: Noise filter
1KM: Magnetic contactor (for control power supply)
2KM: Magnetic contactor (for main circuit power supply)
1Ry: Relay
1PL : Indicator lamp
1SA : Surge absorber
2SA : Surge absorber
3SA : Surge absorber
1D: Flywheel diode
(5) Power Supply Capacities and Power Losses
The following table shows SERVOPACK’s power supply capacities and power losses when using singlephase 200 V power supply.
Main Circuit
Power
Supply
Single-phase,
200 V
Maximum
Applicable
Servomotor
Capacity
[kW]
SERVOPACK
Model SGDV-
0.05
Power Supply
Capacity per
SERVOPACK
[kVA]
R70A 0.2
Output
Current
[Arms]
0.66
0.1
0.2
0.4
0.75
R90A 0.3
1R6A 0.7
2R8A
5R5A
1.2
1.9
0.91
1.6
2.8
5.5
Main
Circuit
Power
Loss
[W]
5.2
7.4
13.7
24.9
52.7
Regenerative
Resistor
Power Loss
[W]
Control
Circuit
Power
Loss
[W]
Total
Power
Loss
[W]
–
8
17
22.2
24.4
30.7
41.9
77.7
Note 1. SGDV-R70A, -R90A, -1R6A, and -2R8A SERVOPACKs do not have built-in regenerative resistors. If the regenerative energy exceeds the specified value, connect an external regenerative resistor between B1/ and B2.
2. Regenerative resistor power losses are allowable losses. Take the following action if this value is exceeded.
• Remove the lead or shorting bar between terminals B2 and B3 on the SERVOPACK main circuit of SGDV-
5R5A SERVOPACKs.
• Install an external regenerative resistor between external regenerative resistor connection terminals B1/ and
B2.
3. External regenerative resistors are not included.
3.1 Main Circuit Wiring
(6) How to Select Molded-case Circuit Breaker and Fuse Capacities
The following table shows the SERVOPACK’s current capacities and inrush current when using single-phase
200 V power supply. Use these values as a basis for selecting the molded-case circuit breaker and fuse.
Main Circuit
Power
Supply
Singlephase,
200 V
Maximum
Applicable
Servomotor
Capacity
[kW]
0.05
0.1
0.2
0.4
0.75
SERVOPACK
Model
SGDV-
Power Supply
Capacity per
SERVOPACK
[kVA]
R70A 0.2
R90A 0.3
1R6A 0.7
2R8A
5R5A
1.2
1.9
Current Capacity
Main
Circuit
[Arms]
Control
Circuit
[Arms]
2
2
3
5
9
0.2
Inrush Current
Main
Circuit
[A0-p]
Control
Circuit
[A0-p]
33
70
33
Note: To comply with the EU low voltage directive, connect a fuse to the input side as protection against accidents caused by short-circuits. Select the fuse for the input side that are compliant with UL standards.
The table above also provides the net values of current capacity and inrush current. Select a fuse and a molded-case circuit breaker which meet the breaking characteristics shown below.
• Main circuit, control circuit: No breaking at three times the current values shown in the table for 5 s.
• Inrush current: No breaking at the current values shown in the table for 20 ms.
3
3-13
3-14
3 Wiring and Connection
3.1.4 Using the SERVOPACK with a DC Power Input
3.1.4
Using the SERVOPACK with a DC Power Input
(1) Parameter Setting
When using a DC power supply, make sure to set the parameter Pn001.2 to 1 (DC power input supported) before inputting DC power.
Pn001
Parameter n.
0 n.
1
Meaning
Enables use of AC power input.
Enables use of DC power input.
When Enabled Classification
After restart Setup
Observe the following precautions.
WARNING
• Either AC or DC power can be input to the 200-V, 400-V SERVOPACKs. Always set Pn001.2 to 1 to specify a DC power input before inputting DC power. Only AC power can be input to the 100-V SERVOPACKs.
If DC power is input without changing the parameter setting, the SERVOPACK’s internal elements will burn and may cause fire or damage to the equipment.
• With a DC power input, time is required to discharge electricity after the main power supply is turned OFF.
A high residual voltage may remain in the SERVOPACK after the power supply is turned OFF. Be careful not to get an electric shock.
• Install fuses on the wires if DC power is used.
• Servomotor returns a regenerated energy to the power supply. The SERVOPACK that can use a DC power supply is not capable of processing the regenerated energy. Provide measures to process the regenerated energy on the power supply.
• If you use a DC power supply input with any of the following SERVOPACKs, externally connect an inrush current limiting circuit and use the power ON and OFF sequences recommended by Yaskawa: SGDV-
330A or -550A.
There is a risk of equipment damage.
(2) DC Power Supply Input Terminals for the Main and Control Circuits
Three-phase, 200 V for SGDV A
( = R70, R90, 1R6, 2R8, 3R8, 5R5, 7R6, 120, 180, 200, 330)
Terminal Symbols
B1/
2
L1C, L2C
Name
Main circuit positive terminal
Main circuit negative terminal
Control power input terminal
Three-phase, 200-V for SGDV-550A
Terminal Symbols
B1/
L1C, L2C
Name
Main circuit positive terminal
Main circuit negative terminal
Control power input terminal
Three-phase, 400 V for SGDV D
( = 1R9, 3R5, 5R4, 8R4, 120, 170, 260)
Terminal Symbols
B1/
2
24 V, 0 V
Name
Main circuit positive terminal
Main circuit negative terminal
Control power input terminal
Specifications
270 to 320 VDC
0 VDC
200 to 230 VAC
Specifications
270 to 320 VDC
0 VDC
200 to 230 VAC
Specifications
513 to 648 VDC
0 VDC
24 VDC ± 15%
3.1 Main Circuit Wiring
(3) Power ON Sequence
If you use a DC power supply input with any of the following SERVOPACKs, use the power ON sequence shown below: SGDV-330A or 260D.
Control power supply OFF ON
Main circuit power supply OFF
Inrush current suppression resistor switch
Switch: Open
Motor power status
Power not supplied.
ON
Switch: Closed (Resistance connected.)
Power supplied.
0.5 s min.
Approx. 2 times switch operating time according to switch specifications
Open switch 0.1 s or longer after power is not supplied to motor.
(4) Wiring Example with DC Power Supply Input
SGDV A SERVOPACKs with 200-VAC Power Supply Input
• SGDV-R70A, -R90A, -1R6A, -2R8A, -3R8A, -5R5A, -7R6A, -120A, -180A, -200A
1QF
R S T
3SA
SERVOPACK
SGDVA
1FLT
2KM
AC/DC
1KM
1FU
U
V
W
M
B1/ +
2
ENC
L1C
L2C
CN1
3 ALM +
1Ry
+24 V
1Ry
(For servo alarm display)
1PL
Servo power Servo power supply ON supply OFF
1KM
4
ALM
−
1D 0 V
1KM
1KM 1Ry
1SA
2KM
1QF
1FLT
1KM
2KM
2SA
: Molded-case circuit breaker
: Noise filter
: Magnetic contactor
(for control power supply)
: Magnetic contactor
(for main circuit power supply)
1FU
1Ry
1PL
1SA
2SA
3SA
1D
: Fuse
: Relay
: Indicator lamp
: Surge absorber
: Surge absorber
: Surge absorber
: Flywheel diode
3
3-15
3-16
3 Wiring and Connection
3.1.4 Using the SERVOPACK with a DC Power Input
• SGDV-330A or -550A
1QF
R S T
3SA
1FLT
2KM
AC/DC
1FU
1R
SERVOPACK
SGDVA
B1/
*
+
2
U
V
W
1TRy
2Ry
M
ENC
4SA
1KM
1Ry
(For servo alarm display)
1PL
Servo power Servo power supply ON supply OFF
1KM
L1C
L2C
CN1
3 ALM +
1Ry
+24 V
4
ALM
−
1D 0 V
1KM
1KM 1Ry
1SA
2KM
+24 V
1TRy
2Ry
0 V
5SA
2SA
1QF
1FLT
1KM
2KM
1FU
1Ry
2Ry
1TRy
: Molded-case circuit breaker
: Noise filter
: Magnetic contactor
(for control power supply)
: Magnetic contactor
(for main circuit power supply)
: Fuse
1PL
1SA
2SA
3SA
4SA
5SA
1D
: Relay
: Relay
1R
(for inrush current suppression resistor switch)
: Timer relay
: Indicator lamp
: Surge absorber
: Surge absorber
: Surge absorber
: Surge absorber
: Surge absorber
: Flywheel diode
: External inrush current suppression resistor
∗ Terminal names differ depending on model of SERVOPACK. Refer to (2) DC Power Supply Input Terminals for the
Main and Control Circuits.
SGDV D SERVOPACKs with 400-VAC Power Supply Input
• SGDV-1R9D, -3R5D, -5R4D, -8R4D, -120D, -170D, -260D
3SA
1QF
R S T
1FLT
2KM
AC/DC
AC/DC
1Ry
(For servo alarm display)
1PL
Servo power Servo power supply ON supply OFF
1KM
1FU
1KM
SERVOPACK
SGDVD
U
V
W
M
B1/ +
2
ENC
24 V
0 V
CN1
3 ALM + 1Ry
+24 V
4 ALM
−
1D 0 V
1KM
1KM 1Ry
1SA
2KM
1QF
1FLT
1KM
2KM
2SA
: Molded-case circuit breaker
: Noise filter
: Magnetic contactor
(for control power supply)
: Magnetic contactor
(for main circuit power supply)
1FU
1Ry
1PL
1SA
2SA
3SA
1D
: Fuse
: Relay
: Indicator lamp
: Surge absorber
: Surge absorber
: Surge absorber
: Flywheel diode
3.1 Main Circuit Wiring
3
3-17
3-18
3 Wiring and Connection
3.1.5 Using More Than One SERVOPACK
3.1.5
Using More Than One SERVOPACK
This section shows an example of the wiring and the precautions when more than one SERVOPACK is used.
(1) Wiring Example
Connect the alarm output (ALM) terminals for three SERVOPACKs in series to enable alarm detection relay
1Ry to operate. When the alarm occurs, the ALM output signal transistor is turned OFF.
Power supply
R S T
1FLT
1QF
3SA
1KM
2KM
Relay terminal
1Ry
(For servo alarm display)
1PL
Servo power supply ON
Servo power supply OFF
1KM
1KM
1KM 1Ry
1SA
2KM
2SA
Relay terminal
1QF: Molded-case circuit breaker
1KM: Magnetic contactor
(for control power supply)
2KM: Magnetic contactor
(for main circuit power supply)
1Ry: Relay
1PL:
1SA:
Indicator lamp
Surge absorber
2SA:
3SA:
Surge absorber
Surge absorber
1D: Flywheel diode
L1
L2
L3
SERVOPACK
Relay terminal
L1C
L2C
CN1
3
ALM+
1Ry
+24 V
4 ALM
−
1D
L1
L2
L3
SERVOPACK
Relay terminal
L1C
L2C
CN1
3
ALM+
4 ALM
−
Servomotor
M
Servomotor
M
L1
L2
L3
SERVOPACK
L1C
L2C
CN1
3
ALM+
4 ALM
−
0 V
Servomotor
M
(2) Precautions
Multiple SERVOPACKs can share a single molded-case circuit breaker (1QF) or noise filter. Always select a molded-case circuit breaker or noise filter that has enough capacity for the total power supply capacity (load conditions) of the SERVOPACKs.
3.1 Main Circuit Wiring
3.1.6
General Precautions for Wiring
CAUTION
• Use shielded twisted-pair cables or screened unshielded twisted-pair cables for I/O signal cables and linear scale connection cables.
• Make sure that the length of each cable is equal to or shorter than the maximum wiring length listed here.
• I/O signal cables: 3 m
• Connection cables for linear servomotor main circuit: 20 m
• Connection cables for serial converter unit: 20 m
• Connection cables for linear scale: 15 m
• Connection cables for hall sensor: 15 m
• Control power supply cables for the SERVOPACK with a 400-V power supply (+24 V, 0 V):10 m
• Use a molded-case circuit breaker (1QF) or fuse to protect the main circuit.
The SERVOPACK connects directly to a commercial power supply; it is not isolated through a transformer or other device.
Always use a molded-case circuit breaker (1QF) or fuse to protect the servo system from accidents involving different power system voltages or other accidents.
• Install a ground fault detector.
The SERVOPACK does not have a built-in protective circuit for grounding. To configure a safer system, install a ground fault detector against overloads and short-circuiting, or install a ground fault detector combined with a molded-case circuit breaker.
• Do not turn the power ON and OFF more than necessary.
• Do not use the SERVOPACK for applications that require the power to turn ON and
OFF frequently. Such applications will cause elements in the SERVOPACK to deteriorate.
• As a guideline, at least one hour should be allowed between the power being turned ON and OFF once actual operation has been started.
To ensure safe, stable application of the servo system, observe the following precautions when wiring.
• Use the connection cables specified in the Σ -V Series Product Catalog and arrange the system so that each cable will be as short as possible.
(No.: KAEP S800000 42). Design
• Observe the following precautions when wiring the ground.
• Use a cable as thick as possible (at least 2.0 mm 2 ).
• Grounding to a resistance of 100 Ω or less for 100-V, 200-V SERVOPACKs, 10 Ω or less for 400-V
SERVOPACKs is recommended.
• Be sure to ground at only one point.
• Ground the servomotor directly if the servomotor is insulated from the machine.
• Do not apply bending stress or tension to the signal cables when you handle them. The core wires are very thin (0.2 mm 2 or 0.3 mm 2 ).
3
3-19
3-20
3 Wiring and Connection
3.2.1 I/O Signal (CN1) Names and Functions
3.2
I/O Signal Connections
This section describes the names and functions of I/O signals (CN1). Also connection examples by control method are shown.
3.2.1
I/O Signal (CN1) Names and Functions
The following table shows the names and functions of I/O signals (CN1).
(1) Input Signals
Signal Pin No.
Name Function
Reference
Section
P-OT
(/SI1)
N-OT
(/SI2)
/DEC
(/SI3)
/EXT 1
(/SI4)
/EXT 2
(/SI5)
/EXT 3
(/SI6)
7
8
9
10
11
12
Forward run prohibited,
Reverse run prohibited
Homing deceleration switch signal
External latch signal 1
External latch signal 2
External latch signal 3
With overtravel prevention: Stops servomotor when movable part travels beyond the allowable range of motion.
Connects the deceleration limit switch for homing.
Connects the external signals that latch the current feedback pulse counter.
4.3.1
−
−
/SI0
/P-CL
/N-CL
13
+24VIN 6
Can be allocated
General-purpose input signal
Control power supply for sequence signals
Used for general-purpose input.
Monitored in the I/O monitor field of MECHATROLINK-II.
Control power supply input for sequence signals.
Allowable voltage fluctuation range: 11 to 25 V
Note: The 24 VDC power supply is not included.
Forward external force limit
Reverse external force limit
The allocation of an input signal to a pin can be changed in accordance with the function required.
−
3.4.1
−
Note 1. You can change the allocations of the input signals (/SI0 to /SI6). For details, refer to 3.3.1 Input Signal Allocations .
2. If the Forward run prohibited/ Reverse run prohibited function is used, the SERVOPACK is stopped by software controls, not by electrical or mechanical means. If the application does not satisfy the safety requirements, add an external circuit for safety reasons as required.
3.2 I/O Signal Connections
(2) Output Signals
Signal Pin No.
Name Function
Reference
Section
ALM+
ALM-
/BK+
(/SO1+)
/BK-
(/SO1-)
/SO2+
/SO2-
/SO3+
/SO3-
3
4
1
2
23
24
25
26
Servo alarm output signal
Brake interlock signal
General-purpose output signal
Turns OFF when an error is detected.
Controls the brake. The brake is released when the signal turns ON (closed).
Allocation can be changed to general-purpose output signals
(/SO1+, /SO1-).
Used for general-purpose output.
Note: Set the parameter to allocate a function.
−
4.3.4
−
/COIN
/V-CMP
/TGON
/S-RDY
/CLT
/VLT
/WARN
/NEAR
Can be allocated
Positioning completion
Speed coincidence detection
Movement detection servo ready
Force limit
Speed limit detection
Warning
Near
The allocation of an output signal to a pin can be changed in accordance with the function required.
−
PAO
/PAO
PBO
/PBO
PCO
/PCO
17
18
19
20
21
22
Phase-A signal
Phase-B signal
Phase-C signal
Encoder output pulse signals with 90
Origin pulse output signal
° phase differential
4.4.4
4.7.2
SG
FG
16
Shell
Signal ground
Frame ground
Connects to the 0 V pin on the control circuit of the host controller.
Connected to frame ground if the shielded wire of the I/O signal cable is connected to the connector shell.
−
−
Note: You can change the allocations of the output signals (/SO1 to /SO3). For details, refer to 3.3.2 Output Signal Allocations .
3.2.2
Safety Function Signal (CN8) Names and Functions
The following table shows the terminal layout of safety function signals (CN8).
Signal Name
/HWBB1+
/HWBB1-
/HWBB2+
/HWBB2-
EDM1+
EDM1-
–
–
Pin No.
4
3
6
5
8
7
1
*
2
*
Hard wire baseblock input 1
Hard wire baseblock input 2
Monitored circuit status output 1
–
–
Function
For hard wire baseblock input.
Baseblock (motor current off) when
OFF.
ON when the /HWBB1 and the
/HWBB2 signals are input and the
SERVOPACK enters a baseblock state.
∗ Do not use pins 1 and 2 because they are connected to the internal circuits.
3
3-21
3-22
3 Wiring and Connection
3.2.3 Example of I/O Signal Connections
3.2.3
Example of I/O Signal Connections
The following diagram shows a typical connection example.
Control power supply for sequence signal
*2
+24 V
Forward run prohibited
(Prohibited when OFF)
Reverse run prohibited
(Prohibited when OFF)
Homing deceleration switch
(Decelerated when ON)
External latch signal 1
(Latched when ON)
External latch signal 2
(Latched when ON)
External latch signal 3
(Latched when ON)
+24VIN
P-OT
N-OT
/DEC
/EXT1
/EXT2
8
/EXT3 12
Generalpurpose /SI0 13
6
7
9
10
11
3.3 k
Ω
SERVOPACK
Photocoupler output
Max. allowable voltage: 30 VDC
Max. allowable current: 50 mA DC
3 ALM+
4 ALM-
Servo alarm output
(OFF for an alarm)
2
23
1 SO1+ / BK+
SO1- / BK-
Brake
(Brake released when ON)
/SO2+
24
25
26
/SO2-
/SO3+
/SO3-
*1
17
18
PAO
/PAO
*4
Encoder output pulse phase A
19
20
PBO
/PBO
21
22
PCO
/PCO
*4
Encoder output pulse phase B
*4
Encoder output pulse phase C
Applicable line receiver:
SN75ALS175 or
MC3486 manufactured by Texas Instruments or the equivalent
16 SG
24 V
Fuse
Safety function device*3
Switch
0 V
/HWBB1+
CN8
4
/HWBB1-
/HWBB2+
3
6
/HWBB25
8
7
EDM1+
EDM1-
SERVOPACK
Connector shell
FG
Connect shield to connector shell.
∗1.
represents twisted-pair wires.
∗2.
The 24-VDC power supply is not included. Use a 24-VDC power supply with double insulation or reinforced insulation.
∗3.
When using a safety function device, refer to 4.9 Safety Function . When not using a safety function device, leave the safety function’s jumper connector that is included with the SERVOPACK inserted in CN8.
∗4.
Always use line receivers to receive the output signals.
Note: The functions allocated to the input signals /DEC, P-OT, N-OT, /EXT1, /EXT2, and /EXT3 and the output signals
/SO1, /SO2, and /SO3 can be changed by using the parameters. For details, refer to 3.3.1 Input Signal Allocations and 3.3.2 Output Signal Allocations .
3.3 I/O Signal Allocations
3.3
I/O Signal Allocations
This section describes the I/O signal allocations.
3.3.1
Input Signal Allocations
• Inverting the polarity of the forward run prohibited and reverse run prohibited signals from the factory setting will prevent the overtravel function from working in case of signal line disconnections or other failures.
If this setting is absolutely necessary, check the operation and confirm that there are no safety problems.
• When two or more signals are allocated to the same input circuit, input signal level is valid for all allocated signals, resulting in an unexpected machine operation.
Input signals are allocated as shown in the following table.
Refer to the Interpreting the Input Signal Allocation Tables and change the allocations accordingly.
<Interpreting the Input Signal Allocation Tables>
Level at which input signal allocations are valid.
The parameter set values to be used are shown.
Signals are allocated to CN1 pins according to the selected set values.
Input Signal Names and Parameters
Validity
Level
Input
Signal
Forward Run Prohibited
Pn50A.3
H
L
P-OT
/P-OT
13
0
9
7
1
A
CN1 Pin Numbers
8
2
B
9
3
C
10 11 12
4
D
5
E
6
F
Connection Not
Required
(SERVOPACK judges the connection)
Always
ON
Always
OFF
7 8
If always ON (7) or always OFF (8) is set, signals will be processed in the SERVOPACK, which will eliminate the need for wiring changes.
Input Signal
Names and
Parameters
Validity
Level
Input
Signal
Forward Run
Prohibited
Pn50A.3
Reverse Run
Prohibited
Pn50B.0
H
L
H
L
CN1 Pin Numbers
P-OT
/P-OT
N-OT
/N-OT
0
9
0
0
13 7 8
1
(Factory setting)
A
1
A
2
B
2
(Factory setting)
B
9
3
C
3
C
10
4
D
4
D
11
5
E
5
E
6
F
6
F
12
Connection Not
Required
(SERVOPACK judges the connection)
Always
ON
Always
OFF
7
7
8
8
3
3-23
3-24
3 Wiring and Connection
3.3.1 Input Signal Allocations
Input Signal
Names and
Parameters
Forward External
Force Limit
Pn50B.2
Reserve External
Force Limit
Pn50B.3
Homing
Deceleration LS
Pn511.0
External Latch
Signal 1
Pn511.1
External Latch
Signal 2
Pn511.2
External Latch
Signal 3
Pn511.3
Validity
Level
L
H
L
H
L
H
L
H
L
H
L
Input
Signal
/P-CL
P-CL
/N-CL
N-CL
/DEC
DEC
EXT1
/EXT1
EXT2
/EXT2
EXT3
13
0
9
0
9
0
9
*
*
*
*
*
7
1
A
1
A
1
A
*
*
*
*
*
8
2
B
2
B
2
B
*
*
*
*
*
*
CN1 Pin Numbers
H /EXT3 * *
∗ These pins cannot be allocated. The setting is not valid.
9
3
C
3
10
4
D
4
11
5
E
5
12
6
F
6
C
3
(Factory setting)
C
*
*
*
*
*
*
D
4
E
5
D
4
(Factory setting)
D
4
D
E
5
E
5
(Factory setting)
E
4
D
5
E
F
6
F
6
F
6
F
6
(Factory setting)
F
7
7
(cont’d)
Connection Not
Required
(SERVOPACK judges the connection)
Always
ON
Always
OFF
8
(Factory setting)
8
(Factory setting)
7
–
–
–
8
0 to 3,
7 to C
0 to 3,
7 to C
0 to 3,
7 to C
3.3 I/O Signal Allocations
3.3.2
Output Signal Allocations
• The signals not detected are considered as " Invalid.
" For example, Positioning Completion (/COIN) signal in speed control is " Invalid.
"
• Inverting the polarity of the brake signal (/BK), i.e. positive logic, will prevent the holding brake from working in case of its signal line disconnection.
If this setting is absolutely necessary, check the operation and confirm that there are no safety problems.
• When two or more signals are allocated to the same output circuit, a signal is output with OR logic circuit.
Output signals are allocated as shown in the following table.
Refer to the Interpreting the Output Signal Allocation Tables and change the allocations accordingly.
<Interpreting the Output Signal Allocation Tables>
The parameter set values to be used are shown.
Signals are allocated to CN1 pins according to the selected set values.
Output Signal Names and Parameters
Brake
Pn50F.2
Output Signal
/BK
1 (2)
1
CN1 Pin Numbers
23 (24)
2
25 (26)
3
Output Signal Names and Parameters
Positioning Completion
Pn50E.0
Speed Coincidence
Detection
Pn50E.1
Movement Detection
Pn50E.2
Servo Ready
Pn50E.3
Force Limit Detection
Pn50F.0
Speed Limit Detection
Pn50F.1
Brake
Pn50F.2
Warning
Pn50F.3
Near
Pn510.0
Pn512.0=1
Pn512.1=1
Pn512.2=1
Output Signal
/COIN
/V-CMP
/TGON
/S-RDY
/CLT
/VLT
/BK
/WARN
/NEAR
1 (2)
1
1
1
1
1
1
1
(Factory setting)
1
1
CN1 Pin Numbers
23 (24)
2
2
2
2
2
2
2
2
2
Polarity inversion of CN1-1(2)
Polarity inversion of CN1-23(24)
Polarity inversion of CN1-25(26)
25 (26)
3
3
3
3
3
3
3
3
3
㸦
Invalid not use
0
㸧
Invalid
(not use)
0
(Factory setting)
0
(Factory setting)
0
(Factory setting)
0
(Factory setting)
0
(Factory setting)
0
(Factory setting)
0
0
(Factory setting)
0
(Factory setting)
0
(Factory setting)
(Not invert at factory setting)
3
3-25
3-26
3 Wiring and Connection
3.4.1 Sequence Input Circuit
3.4
Examples of Connection to Host Controller
This section shows examples of SERVOPACK I/O signal connection to the host controller.
3.4.1
Sequence Input Circuit
(1) Photocoupler Input Circuit
CN1 connector terminals 6 to 13 are explained below.
The sequence input circuit interface is connected through a relay or open-collector transistor circuit. When connecting through a relay, use a low-current relay. If a low-current relay is not used, a faulty contact may result.
Open-collector Circuit Example
24 VDC
Relay Circuit Example
SERVOPACK
+24VIN
3.3 k
Ω
/DEC, etc.
24 VDC
SERVOPACK
+24VIN
3.3 k
Ω
/DEC, etc.
Note: The 24 VDC external power supply capacity must be 50 mA minimum.
The SERVOPACK’s input circuit uses bidirectional photocoupler. Select either the sink circuit or the source circuit according to the specifications required for each machine.
Note 1. The connection examples in 3.2.3 Example of I/O Signal Connections are sink circuit connections.
2. The ON/OFF polarity differs between when a sink circuit is connected and when a source circuit is connected.
Sink Circuit Source Circuit
24 V
+
− SERVOPACK input
24 V
+
− SERVOPACK input
Signal
ON
OFF
Input Signal Polarities
Level
Voltage
Level
Low (L) level
High (H) level
0 V
24 V
Contact
Close
Open
Signal
ON
OFF
Input Signal Polarities
Level
Voltage
Level
High (H) level
Low (L) level
24 V
0 V
Contact
Close
Open
3.4 Examples of Connection to Host Controller
(2) Safety Input Circuit
As for wiring input signals for safety function, input signals make common 0 V. It is necessary to make an input signal redundant.
Input Signal Connection Example
SERVOPACK
CN8
24-V power supply
Switch
Fuse
/HWBB1+ 4 3.3 k
Ω
/HWBB13
3.3 k Ω
/HWBB2+ 6 3.3 k Ω
/HWBB25
3.3 k Ω
3.4.2
Sequence Output Circuit
Three types of SERVOPACK output circuit are available.
Incorrect wiring or incorrect voltage application to the output circuit may cause short-circuit.
If a short-circuit occurs as a result of any of these causes, the holding brake will not work. This could damage the machine or cause an accident resulting in death or injury.
(1) Photocoupler Output Circuit
Photocoupler output circuits are used for servo alarm (ALM), servo ready (/S-RDY), and other sequence output signal circuits. Connect a photocoupler output circuit through a relay or line receiver circuit.
Relay Circuit Example
SERVOPACK
5 to 24 VDC
Relay
Line Receiver Circuit Example
SERVOPACK
5 to 12 VDC
0 V
Note: The maximum allowable voltage and current range of the photocoupler output circuit are as follows:
• Maximum allowable voltage: 30 VDC
• Current range: 5 to 50 mA DC
3
3-27
3-28
3 Wiring and Connection
3.4.2 Sequence Output Circuit
(2) Line Driver Output Circuit
CN1 connector terminals, 17-18 (phase-A signal), 19-20 (phase-B signal), and 21-22 (phase-C signal) are explained below.
These terminals output the following signals via the line-driver output circuits.
• Output signals for which linear scale’s serial data is converted as two phases pulses (PAO, /PAO, PBO, /
PBO)
• Origin pulse signals (PCO, /PCO)
Connect the line-driver output circuit through a line receiver circuit at the host controller.
Line Receiver Circuit Example
SERVOPACK Host Controller
Applicable line receiver:
SN75ALS175 or the equivalent
220 to
470 Ω
SG SG
(3) Safety Output Circuit
The external device monitor (EDM1) for safety output signals is explained below.
A configuration example for the EDM1 output signal is shown in the following diagram.
SERVOPACK
Host controller
CN8
8 EDM1+
24 V Power Supply
7 EDM1-
0 V
Specifications
Type
Output
Signal Name
EDM1
Pin No.
CN8-8
CN8-7
ON
Output
Status
OFF
Meaning
Both the /HWBB1 and /HWBB2 signals are working normally.
The /HWBB1 signal, the /HWBB2 signal, or both are not working normally.
Electrical characteristics of EDM1 signal are as follows.
Items
Maximum Allowable Voltage
Maximum Allowable Current
Maximum Voltage Drop at ON
Maximum Delay Time
Characteristic
30 VDC
50 mADC
1.0 V
20 ms
Remarks
−
−
Voltage between EDM1+ to EDM1- at current is 50 mA.
Time from the change in /HWBB1 or /HWBB2 until the change in EDM1.
3.5 Wiring MECHATROLINKII Communications
3.5
Wiring MECHATROLINK-
II
Communications
The following diagram shows an example of connections between a host controller and a SERVOPACK using
MECHATROLINK-II communications cables (CN6A, CN6B).
MP2300
YASKAWA
RDY
ALM
TX
218IF-01
RUN
BAT
RUN
ERR STRX
TX
ERR
COL
RX
STOP
SUP
INT
CNFG
MON
TEST
ޓ
SW1
OFF
ޓ
ON
INIT
TEST
OFF
PORT
ON
M-
I
/
II
BATTERY
L1
DC24V
DC 0V
10Base-T
L2 Ln
Terminator
Note 1. The length of the cable between stations (L1, L2 ... Ln) must be 0.5 m or more.
2. The total cable length must be L1 + L2 ... + Ln ≤ 50.
3. When multiple SERVOPACKs are connected by MECHATROLINK-II communications cable, a terminator must be installed at the final SERVOPACK.
3
3-29
3-30
3 Wiring and Connection
3.6.1 Linear Scale Signal (CN2) Names and Functions
3.6
Linear Scale Connection
This section describes the linear scale signal (CN2) names, functions, and connection examples.
3.6.1
Linear Scale Signal (CN2) Names and Functions
The following table shows the names and functions of linear scale signals (CN2).
PG5V
PG0V
–
–
PS
/PS
Shield
Signal Name
1
2
3
*
4
*
5
6
Shell
Pin No.
Function
Linear scale power supply +5 V
Linear scale power supply 0 V
–
–
Serial data (+)
Serial data (-)
–
∗ Do not use pins 3 and 4.
3.6.2
Serial Converter Unit
(1) Characteristics and Specifications
The following table shows the characteristics and specifications of the serial converter unit.
Electrical
Characteristics
Mechanical
Characteristics
Environmental
Conditions
Items
Power Supply Voltage
Current Consumption
Signal Resolution
JZDP-D00 -E
+5.0 V ± 5%, ripple content 5% max.
120 mA Typ. 350 mA max.
1/256 pitch of input 2-phase sine wave
250 kHz
JZDP-G00 -E
1/4096 pitch of input 2-phase sine wave pitch
100 kHz Max. Response Frequency
Analog Input Signals*
(cos, sin, Ref)
Hall Sensor Input Signal
Output Signal
Output Method
Differential input amplitude: 0.4 V to 1.2 V
Input signal level: 1.5 V to 3.5 V
CMOS level
Position data, hall sensor information, alarms
Output Circuit
Approx. Mass
Serial data communications
Balanced type transceiver (SN75LBC176 or the equivalent), internal terminating resistor: 120 Ω
150 g
Vibration Resistance 98 m/s
2
max. (10 to 2500 Hz) in three directions
Shock Resistance 980 m/s
2
, (11 ms) two times in three directions
Surrounding Air Temperature 0 ° C to 55 ° C
Storage Temperature -20 ° C to +80 ° C
Humidity 20% to 90%RH (without condensation)
∗ Input a value within the specified range. Otherwise, incorrect position information is output, and the device may be damaged.
3.6 Linear Scale Connection
(2) Model Designations
The following figure shows the model designations of the serial converter unit.
JZDP 00 E
Code
Serial Converter Unit Model
Applicable Linear
Scale
Hall Sensor
D 003
G 003
Manufactured by
Heidenhain
None
D 005
G 005
Manufactured by
Renishaw plc
D 006
G 006
Manufactured by
Heidenhain
D 008
G 008
Manufactured by
Renishaw plc
None
Provided
Provided
Applicable Linear Servomotor
Servomotor Model Symbol
30 A 050 C 250
30 A 080 C 251
40 A 140 C 252
SGLGW -
(Coreless)
When a
Standard force magnetic way is used.
40 A 253 C 253
40 A 365 C 254
60 A 140 C 258
60 A 253 C 259
60 A 365 C 260
90 A 200 C 264
90 A 370 C 265
90 A 535 C 266
SGLGW -
+
SGLGM -
M
( Coreless )
When a highforce magnetic way is used.
40
40
40
60
60
60
A
A
A
A
A
A
140
253
365
140
253
365
C
C
C
C
C
C
255
256
257
261
262
263
20 A 090 A 017
20 A 120 A 018
SGLFW -
(Iron core,
F-type)
35 A 120 A 019
35 A 230 A 020
50 A 200 B 181
50 A 380 B 182
1 ZA 200 B 183
1 ZA 380 B 184
35 D 120 A 211
35 D 230 A 212
50 D 200 B 189
50 D 380 B 190
1 ZD 200 B 191
1 ZD 380 B 192
SGLC -
(Cylinder type)
Servomotor Model
20 A 170 A
20 A 320 A
20 A 460 A
35 A 170 A
35 A 320 A
35 A 460 A
35 A 170 H
SGLTW -
(Iron core,
T-type)
35 A 320 H
50 A 170 H
50 A 320 H
40 A 400 B
40 A 600 B
80 A 400 B
80 A 600 B
35 D 170 H
35 D 320 H
50 D 170 H
50 D 320 H
40 D 400 B
194
195
196
197
40 D 600 B
80 D 400 B
198
199
80 D 600 B 200
D 16 A 085 AP 354
D 16 A 115 AP 373
D 16 A 145 AP 356
D 20 A 100 AP 357
D 20 A 135 AP 358
D 20 A 170 AP 359
D 25 A 125 AP 360
D 25 A 170 AP 374
D 25 A 215 AP 362
D 32 A 165 AP 363
D 32 A 225 AP 364
D 32 A 285 AP 365
106
108
109
185
186
187
188
193
Symbol
011
012
013
014
015
016
105
3
3-31
3-32
3 Wiring and Connection
3.6.2 Serial Converter Unit
(3) Analog Signal Input Timing
Input the analog signals with the timing shown in the following figure.
The /cos and /sin signals are the differential signals when the cos and sin signals are shifted 180 ° . The specifications of the cos, /cos, sin, and /sin signals are identical except for the phases.
The Ref and /Ref signals are input to the comparator. Input a signal that will exceed the hysteresis of the comparator (i.e., the broken lines in the following figure).
When they are crossed, the output data will be counted up.
100%
*1 cos
(A+)
12.5%
12.5% cos, /cos, sin, and /sin input voltage range:
1.5 V to 3.5 V
/cos
(A-) sin
(B+)
/sin
(B-)
*2
12.5% max.
12.5% max.
Ref and /Ref input voltage range:
1.5 V to 3.5 V
/Ref
(R-)
Ref
(R+)
75% max.
Zero Point
75% max.
SERVOPACK origin pulse output position
Count-Up Direction
∗1.
If the analog signal amplitude declines to approximately 0.35 V because of differential amplitude, the serial converter unit will output an alarm.
∗2.
This is the hysteresis width.
• Never perform insulation resistance and withstand voltage tests.
• When low-voltage analog signals are input to the serial converter unit, noise influence on the analog signals affects the unit’s ability to output correct position information.
The analog cable must be as short as possible and shielded.
• Use the serial converter unit in a location without gases such as H
2
S.
• Do not connect or disconnect the unit while power is being supplied, or the unit may be damaged.
• When using multiple axes, use a shielded cable for each axis. Do not use a shielded cable for multiple axes.
• If you use any linear encoder other than a recommended linear encoder, evaluate the system in advance before you use it.
3.6 Linear Scale Connection
3.6.3
Linear Scale Connection Examples
The following diagrams show connection examples of the linear scale, the SERVOPACK, and the host controller.
(1) Incremental Linear Scale
Linear Scale Made by Heidenhain
Linear scale made by Heidenhain
3
11
14
7
4
2
1
9
Connector shell
∗
∗
Shielded wire
COS
/COS
Serial converter unit
CN2
1
9
CN1
2
6
SIN
/SIN
3
11
REF
/REF
14
7
5V
0V
4
2
1
5
Connector shell
Connector shell
∗
PS
/PS
PG5V
PG0V
Shielded wire
SERVOPACK
5
CN2
Phase A
CN1
17
18
6
Phase B 19
20
Phase C
Output line-driver
SN75ALS194 manufactured by Texas
Instruments or the equivalent
21
22
1
2
Connector shell
CN1
0 V
16
Connector shell
SG
PAO
/PAO
PBO
/PBO
PCO
/PCO
∗
represents shielded twisted-pair wires.
R
R
R
Host controller
0 V
Phase A
Phase B
Phase C
Applicable line receiver: SN75ALS175 or MC3486 manufactured by Texas
Instruments, or the equivalent
R (terminating resistance): 220 to 470
Ω
Linear Scale Made by Renishaw plc
Linear scale made by Renishaw plc
9
1
10
2
3
11
4
12
Connector shell
∗
∗
Shielded wire
COS
/COS
Serial converter unit
CN2
9
1
CN1
2
6
SIN
/SIN
10
2
REF
/REF
5V
0V
3
11
4
12
1
5
Connector shell
Connector shell
∗
represents shielded twisted-pair wires.
PS
/PS
PG5V
PG0V
Shielded wire
Host controller
5
6
SERVOPACK
CN2
Phase A
CN1
17
18
Phase B 19
20
Phase C
Output line-driver
SN75ALS194 manufactured by Texas
Instruments or the equivalent
21
22
1
2
Connector shell
CN1
0 V
16
Connector shell
PAO
/PAO
PBO
/PBO
PCO
/PCO
SG
∗
R
R
R
0 V
Phase A
Phase B
Phase C
Applicable line receiver: SN75ALS175 or MC3486 manufactured by Texas
Instruments, or the equivalent
R (terminating resistance): 220 to 470
Ω
3
3-33
3-34
3 Wiring and Connection
3.6.3 Linear Scale Connection Examples
Linear Scale Made by Magnescale Co., Ltd.
• SR75, SR85
Linear scale made by
Magnescale Co., Ltd.
PS
/PS
PG5V
PG0V
5
6
SERVOPACK
CN2
Phase A
Phase B
CN1
17
18
19
20
1
Phase C
Output line-driver
SN75ALS194 manufactured by Texas
Instruments or the equivalent
21
22
2
PAO
/PAO
PBO
/PBO
PCO
/PCO
∗
R
R
R
Host controller
Phase A
Phase B
Phase C
0 V
16 SG
0 V
∗
Connector shell
Shielded wire
Connector shell
0 V
Connector shell
represents shielded twisted-pair wires.
Applicable line receiver: SN75ALS175 or MC3486 manufactured by Texas
Instruments, or the equivalent
R (terminating resistance): 220 to 470
Ω
• SL700, SL710, SL720, SL730
• Head with interpolator PL101-RY
Linear scale
Head
Interpolator
Connection cable made by Magnescale
Co., Ltd.
∗
PS
/PS
PG5V
PG0V
SERVOPACK
CN2
5
Phase A
CN1
17
18
6
Phase B
19
20
Phase C
1
Output line-driver
SN75ALS194 manufactured by Texas
Instruments or the equivalent
21
22
2
PAO
/PAO
PBO
/PBO
PCO
/PCO
∗
R
R
R
Host controller
Phase A
Phase B
Phase C
0 V
16 SG
0 V
∗
Connector shell
Shielded wire
represents shielded twisted-pair wires.
Connector shell
0 V
Connector shell
Applicable line receiver: SN75ALS175 or MC3486 manufactured by Texas
Instruments, or the equivalent
R (terminating resistance): 220 to 470
Ω
3.6 Linear Scale Connection
• SL700, SL710, SL720, SL730
• Interpolator MJ620-T13
Linear scale
Head
Connection cable made by Magnescale
Co., Ltd.
Interpolator
5
6
∗
PS
/PS
PG0V
SERVOPACK
5
CN2
Phase A
CN1
17
18
6
Phase B
19
20
2
Phase C
Output line-driver
SN75ALS194 manufactured by Texas
Instruments or the equivalent
21
22
PAO
/PAO
PBO
/PBO
PCO
/PCO
∗
R
R
R
Host controller
Phase A
Phase B
Phase C
0 V +5 V
External power supply
2
1
12, 14, 16
0 V
16 SG
0 V
∗
Connector shell
Shielded wire
represents shielded twisted-pair wires.
Connector shell
0 V
Connector shell
Applicable line receiver: SN75ALS175 or MC3486 manufactured by Texas
Instruments, or the equivalent
R (terminating resistance): 220 to 470
Ω
(2) Absolute Linear Scale
Linear Scale Made by Heidenhain
Absolute linear scale made by Heidenhain
Head
Interface unit by Heidenhain
Connection cable made by Heidenhain
∗
PS
/PS
SERVOPACK
5
CN2
Phase A
CN1
17
18
6
Phase B 19
20
Phase C 21
22
PG5V
PG0V
Output line driver:
SN75ALS194 or the equivalent
1
2
PAO
/PAO
PBO
/PBO
PCO
/PCO
∗
R
R
R
Host controller
Phase A
Phase B
Phase C
3
Connector shell
Shielded wire
CN1
16 SG
0 V
Connector shell
0 V
Connector shell
0 V
Applicable line receiver:
SN75ALS175 or MC3486 manufactured by Texas Instruments or the equivalent
R (terminating resistance): 220 to 470 Ω
∗ : represents shielded twisted-pair wires.
3-35
3-36
3 Wiring and Connection
3.6.3 Linear Scale Connection Examples
Linear Scale Made by Mitutoyo
Absolute linear scale made by Mitutoyo
2
6
1
5
∗
PS
/PS
PG5V
PG0V
1
2
SERVOPACK
5
CN2
Phase A
CN1
17
18
6
Phase B
19
20
Phase C 21
22
Output line-driver
SN75ALS194 or the equivalent
PAO
/PAO
PBO
/PBO
PCO
/PCO
∗
R
R
R
Host controller
Phase A
Phase B
Phase C
Connector shell
Shielded wire
CN1
16 SG
0 V
0 V
Connector shell
0 V
Connector shell Applicable line receiver: SN75ALS175 or MC3486 manufactured by Texas
Instruments, or the equivalent
R (terminating resistance): 220 to 470
Ω
∗ : represents shielded twisted-pair wires.
Linear Scale Made by Magnescale Co., Ltd.
• SR77, SR87
Absolute linear scale made by Magnescale
PS
/PS
PG5V
PG0V
1
2
SERVOPACK
CN2
5 Phase A
CN1
17
18
6
Phase B
Phase C
19
20
21
22
Output line-driver
SN75ALS194 or the equivalent
PAO
/PAO
PBO
/PBO
PCO
/PCO
∗
R
R
R
Host controller
Phase A
Phase B
Phase C
Connector shell
Shielded wire
CN1
16 SG
0 V
Connector shell
0 V
Connector shell
0 V
Applicable line receiver: SN75ALS175 or MC3486 manufactured by Texas
Instruments, or the equivalent
R (terminating resistance): 220 to 470
Ω
∗ : represents shielded twisted-pair wires.
3.7 Connecting Regenerative Resistors
3.7
Connecting Regenerative Resistors
If the built-in regenerative resistor is insufficient, connect an external regenerative resistor by one of the following methods and set the regenerative resistor capacity (Pn600). As for precautions on selecting a regenerative resistor and its specifications, refer to Σ -V Series Product Catalog (No.: KAEP S800000 42).
WARNING
• Be sure to connect the regenerative resistor correctly. Do not short-circuit between B1/ and B2.
Doing so may result in fire or damage to the regenerative resistor or SERVOPACK.
3.7.1
Connecting Regenerative Resistors
The following instructions show how to connect the regenerative resistors and SERVOPACKs.
(1) SERVOPACKs: Model SGDV-R70F, -R90F, -2R1F, -2R8F, -R70A, -R90A, -1R6A,
-2R8A
Connect an external regenerative resistor between the B1/ and B2 terminals on the SERVOPACK. After connecting a resistor, select the capacity. For more information on how to set the capacity of regenerative resistors, refer to 3.7.2 Setting Regenerative Resistor Capacity .
Enlarged View
(2) SERVOPACKs: Model SGDV-3R8A, -5R5A, -7R6A, -120A, -180A, -200A, -330A,
-1R9D, -3R5D, -5R4D, -8R4D, -120D, -170D
Remove the lead wire between the B2 and B3 terminals of the SERVOPACK, and connect the External
Regenerative Resistor to the B1/ and B2 terminals. After connecting the resistor, select the capacity. For more information on how to set the capacity of regenerative resistors, refer to 3.7.2 Setting Regenerative
Resistor Capacity .
Enlarged View
3
CAUTION
• When connecting an External Regenerative Resistor to the SGDV-3R8A, -5R5A, -7R6A, -120A,
-180A, -200A, -330A, -1R9D, -3R5D, -5R4D, -8R4D, -120D, or -170D, first remove the lead wire between the B2 and B3 terminals on the SERVOPACK, and then connect the External Regenerative Resistor.
There is a risk of SERVOPACK failure.
3-37
3-38
3 Wiring and Connection
3.7.1 Connecting Regenerative Resistors
(3) SERVOPACKs: Model SGDV-550A and -260D
No built-in regenerative resistor is provided, so the external regenerative resistor is required. The regenerative resistor units are as follows:
Note: The regenerative resistor unit is constructed from a number of resistors.
Main Circuit
Power Supply
Applicable
SERVOPACK Model
SGDV-
550A
Applicable
Regenerative
Resistor Unit
JUSP-RA05-E
Resistance ( Ω )
Specifications
Three-phase
200 V
3.13
Eight 25 Ω (220 W) resistors are connected in parallel.
Three-phase
400 V
260D JUSP-RA18-E 18 Two series of two 18 Ω (220 W) resistors each are connected in parallel.
Use Pn600 at the factory setting when you use a Yaskawa regenerative resistor unit. Set Pn600 when using a non-YASKAWA external regenerative resistor.
Connect the R1 terminal on the Regenerative Resistor Unit to the B1/ terminal on the SERVOPACK, and connect the R2 terminal on the Regenerative Resistor Unit to the B2 terminal on the SERVOPACK.
SERVOPACK
Regenerative Resistor Unit
JUSP-RA -E
The location of the R1 and R2 terminals on the Regenerative Resistor Unit will depend on the model.
JUSP-RA05-E JUSP-RA18-E
3.7 Connecting Regenerative Resistors
3.7.2
Setting Regenerative Resistor Capacity
When a non-Yaskawa external regenerative resistor is connected, always set Pn600 (Regenerative Resistor
Capacity) to the resistor capacity.
WARNING
• If Pn600 is set to 0 when a non-Yaskawa external regenerative resistor is connected, regenerative overload alarms (A.320) may not be detected. If the regenerative overload alarm (A.320) is not detected correctly, the external regenerative resistor may be damaged and an injury or fire may result.
Pn600
Regenerative Resistor Capacity
Setting Range Unit
Speed Position Force
Factory Setting When Enabled
0 to SERVOPACK capacity
10 W 0 Immediately
Classification
Setup
Be sure to set the regenerative resistor capacity (Pn600) to a value that is in accordance with the allowable capacity of the actual external regenerative resistor being used.
Note 1. If Pn600 is not set to the optimum value, alarm A.320 will occur.
2. When set to the factory setting (Pn600 = 0), the SERVOPACK’s built-in resistor or Yaskawa’s regenerative resistor unit has been used.
The setting will vary with the cooling method of external regenerative resistor:
• For natural convection cooling: Set the value to a maximum 20% of the actually installed regenerative
resistor capacity (W).
• For forced convection cooling: Set the value to a maximum 50% of the actually installed regenerative
resistor capacity (W).
Example: Set 20 W (100 W × 20%) for the 100-W external regenerative resistor with natural convection
cooling method:
Pn600 = 2 (unit: 10 W)
• When the external regenerative resistors for power are used at the rated load ratio, the resistor temperature increases to between 200 and 300 ° C. The resistors must be used at or below the rated values. Check with the manufacturer for the resistor’s load characteristics.
• For safety, use the external regenerative resistors with thermoswitches.
3
3-39
3-40
3 Wiring and Connection
3.8.1 Wiring for Noise Control
3.8
Noise Control and Measures for Harmonic Suppression
This section describes the wiring for noise control and the DC reactor for harmonic suppression.
3.8.1
Wiring for Noise Control
• Because the SERVOPACK is designed as an industrial device, it provides no mechanism to prevent noise interference.
• The SERVOPACK uses high-speed switching elements in the main circuit. Therefore peripheral devices may receive switching noise. If the equipment is to be used near private houses or if radio interference is a problem, take countermeasures against noise.
• If installation conditions by the EMC directive must be met, refer to 2.5 EMC Installation Conditions in Σ V Series User's Manual Setup Linear Motor (No.: SIEP S800000
44).
The SERVOPACK uses microprocessors. Therefore it may receive switching noise from peripheral devices.
To prevent the noise from the SERVOPACK or the peripheral devices from causing a malfunction of any one of these devices, take the following precautions against noise as required.
• Position the input reference device and noise filter as close to the SERVOPACK as possible.
• Always install a surge absorber in the relay, solenoid and electromagnetic contactor coils.
• Do not bundle or run the main circuit cables together with the I/O signal cables or the linear scale connection cables in the same duct. Keep the main circuit cables separated from the I/O signal cables and the linear scale connection cables with a gap of at least 30 cm.
• Do not use the same power supply as electric welders, electrical discharge machines, and similar devices. If the SERVOPACK is placed near equipment that generates high-frequency noise, install a noise filter on the input side of the main circuit power supply cable and control power supply cable, even if the same power supply is not used. Refer to (1) Noise Filter for the noise filter connection method.
• Take the grounding measures correctly. As for the grounding, refer to (2) Correct Grounding.
3.8 Noise Control and Measures for Harmonic Suppression
(1) Noise Filter
The SERVOPACK has a built-in microprocessor (CPU), so protect it from external noise as much as possible by installing a noise filter in the appropriate place.
The following is an example of wiring for noise control.
200 VAC
Noise filter
∗ 3
2.0 mm
2 min.
SERVOPACK
L1
L2
L3
U
V
W
L1C
L2C
CN1
CN2
2.0 mm
2 min .
Servomotor
M
(FG)
ENC
Operation relay sequence
Signal generation circuit (not included)
∗ 3
Noise filter
∗
2
DC power
2.0 mm 2 min .
(Ground plate)
∗ 1
Ground: Ground to an independent ground
∗1.
For ground wires connected to the ground plate, use a thick wire with a thickness of at least 2.0 mm
2 plain stitch cooper wire).
(preferably,
∗2.
should be twisted-pair wires.
∗3.
When using a noise filter, follow the precautions in 3.8.2 Precautions on Connecting Noise Filter .
(2) Correct Grounding
Take the following grounding measures to prevent the malfunction due to noise.
Grounding the Motor
Always connect ground terminal FG to the SERVOPACK ground terminal . Also be sure to ground the ground terminal .
Ground both coil assembly and magnetic way of the servomotor.
If the servomotor is grounded via the machine, a switching noise current will flow from the SERVOPACK main circuit through servomotor stray capacitance. The above grounding is required to prevent the adverse effects of switching noise.
Noise on the I/O Signal Cable
If the I/O signal cable receives noise, ground the 0 V line (SG) of the I/O signal cable. If the servomotor main circuit cable is accommodated in a metal conduit, ground the conduit and its junction box. For all grounding, ground at one point only.
3
3-41
3-42
3 Wiring and Connection
3.8.2 Precautions on Connecting Noise Filter
3.8.2
Precautions on Connecting Noise Filter
This section describes the precautions on installing a noise filter.
(1) Precautions on Using Noise Filters
Always observe the following installation and wiring instructions.
Some noise filters have large leakage currents. The grounding measures taken also affects the extent of the leakage current. If necessary, select an appropriate leakage current detector or leakage current breaker taking into account the grounding measures that are used and leakage current from the noise filter. Contact the manufacturer of the noise filter for details.
Do not put the input and output lines in the same duct or bundle them together.
Incorrect Correct
Noise
Filter
Ground plate Ground plate
Noise
Filter
Noise
Filter
Noise
Filter
Ground plate Ground plate
Separate these circuits
Separate the noise filter ground wire from the output lines.
Do not accommodate the noise filter ground wire, output lines and other signal lines in the same duct or bundle them together.
Incorrect Correct
Noise
Filter
Noise
Filter
The ground wire can be close to input lines.
Ground plate Ground plate
3.8 Noise Control and Measures for Harmonic Suppression
Connect the noise filter ground wire directly to the ground plate.
Do not connect the noise filter ground wire to other ground wires.
Incorrect Correct
Noise
Filter
SERVOPACK SERVOPACK
Noise
Filter
SERVOPACK SERVOPACK
Shielded ground wire
Ground plate Ground plate
If a noise filter is located inside a control panel, first connect the noise filter ground wire and the ground wires from other devices inside the control panel to the ground plate for the control panel, then ground the plates.
Noise
Filter
Control Panel
SERVOPACK
SERVOPACK
Ground
Ground plate
3.8.3
Connecting a Reactor for Harmonic Suppression
The SERVOPACK has reactor connection terminals for power supply harmonic suppression that can be used as required. The reactor is an optional part. You must acquire it separately. For reactor selection and specifications, refer to the Σ -V Series Product Catalog (Catalog No.: KAEP S800000 42).
Connect a reactor as shown in the following diagram.
SERVOPACK with 100-VAC Power Input
Power supply
SERVOPACK
AC reactor
L1
L2
SERVOPACK with 200/400-VAC Power Input
SERVOPACK
DC reactor
1
2
3
Note 1. Connection terminals for DC reactor 1 and 2 are short-circuited at shipment. Remove the lead wire for short-circuit, and connect a DC reactor.
2. DC reactors cannot be connected to SERVOPACKs with a single-phase 100-V power input.
3-43
4
Operation
4.1 MECHATROLINKII Communications Settings . . . . . . . . . . . . . . . . . . . . 4-3
4.1.1 Setting the Communications Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
4.1.2 Setting the Station Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
4.2 MECHATROLINKII Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
4.3 Basic Functions Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
4.3.1 Servomotor Movement Direction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
4.3.2 Overtravel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
4.3.3 Software Limit Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
4.3.4 Holding Brakes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
4.3.5 Stopping Servomotors after SV_OFF Command or Alarm Occurrence . . . . . . . . . . 4-14
4.3.6 Instantaneous Power Interruption Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16
4.3.7 Motor Maximum Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17
4.3.8 SEMI F47 Function
(Force Limit Function for Low DC Power Supply Voltage for Main Circuit) . . . . . . . . 4-18
4.3.9 Setting Motor Overload Detection Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21
4.4 Trial Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-23
4.4.1 Inspection and Checking before Trial Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-23
4.4.2 Trial Operation via MECHATROLINKII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24
4.4.3 Electronic Gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-25
4.4.4 Encoder Output Pulses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-28
4.4.5 Setting Encoder Output Pulse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-33
4.5 Test Without Motor Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-35
4.5.1 Motor Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-35
4.5.2 Motor Position and Speed Responses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-36
4.5.3 Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-36
4.5.4 Digital Operator Displays during Testing without Motor . . . . . . . . . . . . . . . . . . . . . . . 4-37
4.6 Limiting Force . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-38
4.6.1 Internal Force Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-38
4.6.2 External Force Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-39
4.6.3 Checking Output Force Limiting during Operation . . . . . . . . . . . . . . . . . . . . . . . . . . 4-40
4.7 Absolute Linear Scales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-41
4.7.1 Absolute Data Request (SENS ON Command) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-41
4.7.2 Absolute Data Reception Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-42
4.7.3 Absolute Encoder Origin Offset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-45
4
4-1
4-2
4 Operation
4.8 Other Output Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-46
4.8.1 Servo Alarm Output Signal (ALM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-46
4.8.2 Warning Output Signal (/WARN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-46
4.8.3 Movement Detection Output Signal (/TGON) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-47
4.8.4 Servo Ready Output Signal (/S-RDY) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-47
4.8.5 Speed Coincidence Output Signal (/V-CMP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-49
4.8.6 Positioning Completed Output Signal (/COIN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-50
4.8.7 Positioning Near Output Signal (/NEAR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-51
4.8.8 Speed Limit Detection Signal (/VLT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-52
4.9 Safety Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-54
4.9.1 Hard Wire Base Block (HWBB) Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-54
4.9.2 External Device Monitor (EDM1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-60
4.9.3 Application Example of Safety Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-62
4.9.4 Confirming Safety Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-63
4.9.5 Safety Device Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-64
4.9.6 Precautions for Safety Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-65
4.1 MECHATROLINKII Communications Settings
4.1
MECHATROLINK-
II
Communications Settings
The DIP switch (SW2) is used to make the settings for MECHATROLINK-II communications.
The station address is set using the rotary switch (SW1) and the DIP switch (SW2).
ON
OFF
1 2 3 4
SW2 (factory settings)
D
E
F
C
B
A
9
0
8
1
2
3
4
6
5
7
SW1 (factory setting)
4.1.1
Setting the Communications Specifications
Set the communications specifications on the DIP switch (SW2).
SW2 Function
Pin 1 Sets the baud rate.
Pin 3 Sets the station address.
Pin 4 Reserved. (Do not change.)
Setting Description
OFF 4 Mbps (MECHATROLINK-I)
ON 10 Mbps (MECHATROLINK-II)
OFF 17 bytes
ON 32 bytes
OFF Station address = 40h + SW1
ON
OFF
Station address = 50h + SW1
−
Factory setting
ON
ON
OFF
OFF
• When connecting to a MECHATROLINK-I network, turn OFF pins 1 and 2.
• When using a MECHATROLINK-I network (Baud rate: 4 Mbps), the settings for the number of transmission bytes is disabled and the number of transmission bytes is always 17.
4
4-3
4-4
4 Operation
4.1.2 Setting the Station Address
4.1.2
Setting the Station Address
The following table lists the possible settings of the rotary switch (SW1) and the DIP switch (SW2) that can be combined to form a station address.
The factory setting for the station address is 41h (SW2 = OFF, SW1 = 1).
D
E
F
9
A
B
C
5
6
3
4
7
8
0
1
2
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Bit 3 of SW2
OFF
OFF
OFF
OFF
OFF
SW1
49h
4Ah
4Bh
4Ch
45h
46h
47h
48h
Station Address
Disabled
41h
42h
43h
44h
4Dh
4Eh
4Fh
D
E
F
9
A
B
C
5
6
3
4
7
8
0
1
2
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
Bit 3 of SW2
ON
ON
SW1
59h
5Ah
5Bh
5Ch
55h
56h
57h
58h
Station Address
50h
51h
52h
53h
54h
5Dh
5Eh
5Fh
• After changing the setting, turn the power supply to the SERVOPACK OFF and ON again to enable the new setting.
4.2
MECHATROLINK-
II
Commands
For details on MECHATROLINK-II commands, refer to the
S800000 54).
Σ -V Series/DC Power Input Σ -V Series/ Σ -V
Series for Large-Capacity Models User’s Manual MECHATROLINK-II Commands (Manual No.: SIEP
4.3 Basic Functions Settings
4.3
Basic Functions Settings
4.3.1
Servomotor Movement Direction
The servomotor movement direction can be reversed with parameter Pn000.0 without changing the polarity of the speed/position reference. This causes the movement direction of the servomotor to change, but the polarity of the signal, such as encoder output pulses, output from the SERVOPACK does not change. (refer to 4.4.4
Encoder Output Pulses )
Before you set this parameter, make sure that the motor phase (Pn080.1) has been set correctly. For the
Pn080.1 setting method, refer to the Σ -V Series User’s Manual, Setup, Linear Motor (No. SIEP S800000 44).
Parameter
Forward/
Reverse
Reference
Direction of Motor Movement and Encoder Output Pulse
Applicable
Overtravel
(OT) n.
0
The linear scale counts up by a forward reference.
[Factory setting]
Forward
Reference
Reverse
Reference
Moves in forward direction
Motor speed
+ Force reference
Motor speed
Encoder output pulse
Time
PAO
PBO Phase B advanced
Moves in reverse direction
+ Motor speed
Force reference
Time
Encoder output pulse
PAO
Phase A advanced
PBO
Motor speed
Pn000 n.
1
The linear scale counts up by a reverse reference.
Forward
Reference
Reverse
Reference
Moves in reverse direction
+
Motor speed
Force reference
Motor speed
Encoder output pulse
Time
PAO
PBO Phase B advanced
Moves in forward direction
+
Motor speed
Force reference
Time
Encoder output pulse
PAO
PBO
Phase A advanced
Motor speed
Note: SigmaWin+ trace waveforms are shown in the above table.
P-OT
N-OT
P-OT
N-OT
4
4-5
4-6
4 Operation
4.3.2 Overtravel
4.3.2
Overtravel
The overtravel limit function forces movable machine parts to stop if they exceed the allowable range of motion and turn ON a limit switch.
CAUTION
• Installing limit switches
For machines that move using linear motion, connect limit switches to P-OT and N-OT of CN1 as shown below to prevent machine damage. To prevent a contact fault or disconnection from causing accidents, make sure that the limit switches are normally closed.
Servomotor
Forward direction
SERVOPACK
Limit switch
Limit switch
N-OT
CN1
8
P-OT
7
• Axes to which external force is applied in overtravel
Vertical axes:
There is a risk of the workpiece falling during the overtravel status because the /BK signal will remain ON (brake release). Set the zero clamp status after the servomotor stops (Pn001 = n.
1 ) to prevent the workpiece from falling.
Other axes to which external force is applied:
Overtravel will bring about a baseblock state after the servomotor stops, which may cause the servomotor to be pushed back by the load’s external force. To prevent this, set the parameter (Pn001 = n.
1 ) to bring the servomotor to zero clamp state after stopping.
For details on how to set the parameter, refer to (3) Servomotor Stopping Method When Overtravel is Used .
(1) Signal Setting
Type Name
Connector
Pin Number
Setting Meaning
Input
P-OT
N-OT
CN1-7
CN1-8
ON
OFF
ON
OFF
Forward run allowed.
Normal operation status.
Forward run prohibited. Forward overtravel.
Reverse run allowed. Normal operation status.
Reverse run prohibited. Reverse overtravel.
Movement in the opposite direction is possible during overtravel by inputting the reference.
(2) Overtravel Function Setting
Parameters Pn50A and Pn50B can be set to enable or disable the overtravel function.
If the overtravel function is not used, no wiring for overtravel input signals will be required.
Parameter Meaning
When
Enabled
Pn50A
Pn50B n.1
[Factory setting] n.8
n.
2 [Factory setting] n.
8
Inputs the Forward Run Prohibited (P-OT) signal from
CN1-7.
Disables the Forward Run Prohibited (P-OT) signal.
Allows constant forward movement.
Inputs the Reverse Run Prohibited (N-OT) signal from
CN1-8.
Disables the Reverse Run Prohibited (N-OT) signal.
Allows constant reverse movement.
After restart
Classification
Setup
A parameter can be used to re-allocate input connector number for the P-OT and N-OT signals. Refer to 3.3.1
Input Signal Allocations for details.
4.3 Basic Functions Settings
(3) Servomotor Stopping Method When Overtravel is Used
There are three servomotor stopping methods when an overtravel is used.
• Dynamic brake
By short-circuiting the electric circuits, the servomotor comes to a quick stop.
• Decelerate to a stop
Stops by using emergency stop force.
• Coast to a stop
Stops naturally, with no control, by using the friction resistance of the servomotor in operation.
After servomotor stopping, there are two modes.
• Coast mode
Stopped naturally, with no control, by using the friction resistance of the servomotor in operation.
• Zero clamp mode
A mode forms a position loop by using the position reference zero.
The servomotor stopping method when an overtravel (P-OT, N-OT) signal is input while the servomotor is operating can be set with parameter Pn001.
Stop Method
Mode After
Stopping
When Enabled Classification
Pn001
Parameter n.
00
[Factory setting] n.
01 n.
02 n.
1 n.
2
DB
Coast
Coast
Deceleration to a stop
Zero clamp
Coast
After restart Setup
• A servomotor under force control cannot be decelerated to a stop. The servomotor is stopped with the dynamic braking (DB) or coasts to a stop according to the setting of Pn001.0. After the servomotor stops, the servomotor will enter a coast state.
• For details on servomotor stopping methods after the SV_OFF command is received or an alarm occurs, refer to 4.3.5 Stopping Servomotors after SV_OFF Command or Alarm Occurrence .
When Servomotor Stopping Method is Set to Decelerate to Stop
Emergency stop force can be set with Pn406.
Pn406
Emergency Stop Force
Setting Range Setting Unit
Speed Position
Factory Setting
When Enabled
0 to 800 1%
* 800 Immediately
Classification
Setup
∗ Percentage (%) of rated motor force.
Note: The factory setting is 800% so that the setting is large enough a value to operate the servomotor at maximum force.
The maximum value of emergency stop force that is actually available, however, is limited to the maximum force of the servomotor.
4
4-7
4-8
4 Operation
4.3.2 Overtravel
(4) Overtravel Warning Function
This function detects an overtravel warning (A.9A0) if overtravel occurs while the servomotor power is ON.
Using this function enables notifying the host controller when the SERVOPACK detects overtravel even if the overtravel signal is ON only momentarily.
To use this function, set Pn00D to n.1
(Detects overtravel warning).
Note: The overtravel warning function is supported by software version 001A or later. The software version can be checked with Fn012. For details, refer to 6.14 Software Version Display (Fn012) .
Warning Output Timing
Command
Motion command ALM_CLR command
Servomotor power OFF ON
Overtravel input signal
㧔 P-OT, N-OT signals 㧕
Disabled Enabled
Overtravel warning
㧔 A.9A0
㧕
Disabled
Normal operation
Enabled
Disabled
Warning status
Normal operation
Warning not detected.
<Notes>
• Warnings are detected for overtravel in the same direction as the reference.
• Warnings are not detected for overtravel in the reverse direction from the reference.
Example:A warning will not be output for a forward reference even if the N-OT signal (reverse run prohibited) turns ON.
• A warning can be detected in either the forward or reverse direction, when there is no reference.
• A warning will not be detected when the servomotor power is OFF even if overtravel occurs.
• A warning will not be detected when the servomotor power changes from OFF to ON even if overtravel status exists.
• To clear the overtravel warning, send a Clear Warning or Alarm command (ALM_CLR) regardless of the status of the servomotor power and the overtravel signal. If the warning is cleared by this method during an overtravel state, the occurrence of the warning will not be indicated until the overtraveling is corrected and reset.
• The overtravel warning will be detected when the software limit is in effect.
CAUTION
• The overtravel warning function only detects warnings. It does not affect on stopping for overtravel or motion operations at the host controller. The next step (e.g., the next motion or other command) can be executed even if an overtravel warning exists. However, depending on the processing specifications and programming for warnings in the host controller, operation may be affected when an overtravel warning occurs (e.g., motion may stop or not stop). Confirm the specifications and programming in the host controller.
• When an overtravel occurs, the SERVOPACK will perform stop processing for overtravel. Therefore, when an overtravel warning occurs, the servomotor may not reach the target position specified by the host controller. Check the feedback position to make sure that the axis is stopped at a safe position.
Related Parameter
Pn00D
Parameter n.0
[Factory setting] n.1
Meaning
Does not detect overtravel warning.
Detects overtravel warning.
When Enabled Classification
Immediately Setup
4.3 Basic Functions Settings
4.3.3
Software Limit Settings
The software limits set limits in software for machine movement that do not use the overtravel signals (P-OT and N-OT). If a software limit is exceeded, an emergency stop will be executed in the same way as it is for overtravel.
(1) Software Limit Function
The software limit function can be enabled or disabled.
Use the parameter Pn801.0 to enable the software limit function.
The software limit function can be enabled under the following conditions. Under all other circumstances, the software limits will not be enabled even if a software limit is exceeded.
• The ZRET command has been executed.
• REFE = 1 using the POS_SET command.
Enable or disable the software limits using one of the following settings.
Pn801
Parameter n.
0 n.
1 n.
2 n.
3
[Factory setting]
Description
Software limits enabled in both direction.
Forward software limit enabled.
Reverse software limit enabled.
Both software limits disabled.
When Enabled Classification
Immediately Setup
(2) Software Limit Check using References
Enable or disable software limit checks when target position references such as POSING or INTERPOLATE are input. When the input target position exceeds the software limit, a deceleration stop will be performed from the software limit set position.
When Enabled Classification
Pn801
Parameter n.
0
[Factory setting] n.
1
Description
No software limit check using references.
Software limit check using references.
Immediately Setup
(3) Software Limit Setting
Set the forward and reverse software limit values.
The area will be set in both directions. Always set the software limits so that the reverse limit value is less than the forward limit value.
Pn804
Pn806
Forward Software Limit
Setting Range
-1073741823 to
1073741823
Reverse Software Limit
Setting Unit
1 Reference Unit
Setting Range
-1073741823 to
1073741823
Setting Unit
1 Reference Unit
Factory Setting
1073741823
Factory Setting
-1073741823
Position
When Enabled
Immediately
Position
When Enabled
Immediately
Classification
Setup
Classification
Setup
4
4-9
4-10
4 Operation
4.3.4 Holding Brakes
4.3.4
Holding Brakes
A holding brake is a brake used to hold the position of the movable part of the machine when the SERVO-
PACK is turned OFF so that movable part does not move due to gravity or external forces. The brake is not included, so if necessary, install a holding brake on the machine.
The brake has the following operation delay times:
• Brake release time: The time from when the brake (/BK) signal is turned ON to when the brake actually releases.
• Brake operation time: The time from when the brake (/BK) signal is turned OFF to when the brake is actually applied.
Set the operation ON and OFF timing as shown below while taking into consideration the brake operation delay times.
Servo ON command
(SV_ON)
Servo OFF
OFF
Servomotor power
Brake signal (/BK)
OFF
Brake contact part
(lining)
Brake applied
*1
Position reference/
Speed reference
0
Servo ON
ON
ON
Brake release
*1
Servo OFF
*3
OFF
OFF
Brake applied
Motor speed
*2
∗1.
The brake operation delay times depend on the model of brake that you use. Set the parameters related to the brake signal (/BK) output timing according to the operation delay times for your brake.
∗2.
After the SV_ON command is sent, wait at least for the brake release time plus 50 ms, and then output the reference from the host controller to the SERVOPACK.
∗3.
Set the brake operation and servo OFF timing with Pn506, Pn508, and Pn583.
4.3 Basic Functions Settings
(1) Wiring Example
Use the brake signal (/BK) and the brake power supply to form a brake ON/OFF circuit. The following diagram shows a standard wiring example.
The timing can be easily set using the brake signal (/BK).
Servomotor
Power supply
SERVOPACK
L1
L2
L3
L1C
L2C
U
V
W
CN2
CN1
(/BK+)
BK-RY
+24 V
(/BK-)
1D
0 V
M
ENC
AC side DC side
Brake power supply
BK-RY
AC DC BK
Note: A brake and its power supply are not included.
• Configure the relay circuit to apply the holding brake by the emergency stop.
Relay Circuit Example
SERVOPACK
5 to 24 VDC
Emergency stop
Photocoupler
0 V
• The allocation of the /BK signal can be changed. Refer to (3) Brake Signal (/BK) Allocation to set the parameter Pn50F.
• When using a 24-V brake, separate the 24-VDC power supply from other power supplies, such as the one used for the I/O signals of CN1 connectors. Always install the
24-VDC power supply separately. If the power supply is shared, the I/O signals might malfunction.
4
4-11
4-12
4 Operation
4.3.4 Holding Brakes
(2) Brake Signal (/BK) Setting
This output signal controls the brake. The allocation of the /BK signal can be changed. For details, refer to (3)
Brake Signal (/BK) Allocation .
The /BK signal turns OFF (applies the brake) when an alarm is detected or the SV_OFF command is received.
The brake OFF timing can be adjusted with Pn506.
Type
Output /BK
Name
Connector
Pin Number
CN1-1, CN1-2
Setting
ON (closed)
OFF (open)
Meaning
Releases the brake.
Applies the brake.
The /BK signal is still ON during overtravel and the brake is still released.
(3) Brake Signal (/BK) Allocation
Use parameter Pn50F.2 to allocate the /BK signal.
Parameter
Pn50F n.
0 n.
1
[Factory setting] n.
2 n.
3
Connector
Pin Number
+ Terminal - Terminal
– –
Meaning
The /BK signal is not used.
CN1-1
CN1-23
CN1-25
CN1-2
CN1-24
CN1-26
The /BK signal is output from output terminal CN1-1, 2.
The /BK signal is output from output terminal CN1-23, 24.
The /BK signal is output from output terminal CN1-25, 26.
When
Enabled
Classification
After restart
Setup
When multiple signals are allocated to the same output terminal, the signals are output with OR logic. For the /BK signal, do not use the output terminal that is already being used for another signal.
(4) Brake ON Timing after the Servomotor Stops
When the servomotor stops, the /BK signal turns OFF at the same time as the SV_OFF command is received.
Use parameter Pn506 to change the timing to turn OFF the servomotor power after the SV_OFF command has been received.
Pn506
Brake Reference-Servo OFF Delay Time
Setting Range
0 to 50
Setting Unit
10 ms
Speed
Factory Setting
0
Position Force
When Enabled
Immediately
Classification
Setup
4.3 Basic Functions Settings
• When using the servomotor to control a vertical axis, the machine movable part may shift slightly depending on the brake ON timing due to gravity or an external force. To eliminate this slight shift, set parameter so that the power to the servomotor turns
OFF after the brake is applied.
• This parameter changes the brake ON timing while the servomotor is stopped.
SV_OFF command Servo ON Servo OFF
/BK output
Power to motor
Brake released
(ON)
Brake applied
(OFF)
Power to motor No power to motor
Pn506
The servomotor will turn OFF immediately when an alarm occurs, regardless of the setting of this parameter. The machine movable part may shift due to gravity or external force before the brake operates.
(5) Brake Signal (/BK) Output Timing during Servomotor Movement
If an alarm occurs while the servomotor is moving, the servomotor will come to a stop and the brake signal
(/BK) will be turned OFF. The timing of brake signal (/BK) output can be adjusted by setting the brake reference output speed level (Pn583) and the waiting time for brake signal when motor running (Pn508).
Note: If the stopping method when an alarm occurs is set to a zero-speed stop, the operation described in (4) Brake ON
Timing after the Servomotor Stops is performed after the servomotor stops.
Pn583
Pn508
Brake Reference Output Speed Level
Setting Range
0 to 10000
Setting Unit
1 mm/s
Speed
Factory Setting
10
Waiting Time for Brake Signal When Motor Running
Setting Range
10 to 100
Setting Unit
10 ms
Speed
Factory Setting
50
Position
Force
When Enabled
Immediately
Position Force
When Enabled
Immediately
Classification
Setup
Classification
Setup
/BK Signal Output Conditions
When Servomotor Moving
The /BK signal goes to high level
(brake ON) when either of the following conditions is satisfied:
• When the motor speed falls below the level set in Pn583 after the power to the servomotor is turned OFF.
• When the time set in Pn508 is exceeded after the power to the servomotor is turned OFF.
SV_OFF command or alarm or power OFF
Servo ON
Motor speed
Power to motor
/BK output
ON
Brake released
(ON)
Servo OFF
Pn583 Motor stopped by applying
DB or by coasting Pn001.0
OFF
Brake applied
(OFF)
Pn508 4
• The servomotor will be limited to its maximum speed even if the value set in Pn583 is higher than the maximum speed.
• Do not allocate the movement detection signal (/TGON) and the brake signal (/BK) to the same terminal. The /TGON signal will otherwise be turned ON by the falling speed on a vertical axis, and the brake may not operate.
For the /BK signal, do not use the terminal that is already being used for another signal.
4-13
4-14
4 Operation
4.3.5 Stopping Servomotors after SV_OFF Command or Alarm Occurrence
4.3.5
Stopping Servomotors after SV_OFF Command or Alarm Occurrence
The servomotor stopping method can be selected after the SV_OFF command is received or an alarm occurs.
• Dynamic braking (DB) is used for emergency stops. The DB circuit will operate frequently if the power is turned ON and OFF or the SV_ON command is received with a reference input applied to start and stop the servomotor, which may result in deterioration of the internal elements in the SERVOPACK.
Use speed input references or position references to start and stop the servomotor.
• If the main circuit power supply or the control power supply is turned OFF but the
SV_OFF command has not been received, the stopping method for servomotor cannot be set in the parameters. Use the following method to stop the servomotor.
If turning OFF the main circuit power supply, but the SV_OFF command has not been received, the servomotor will be stopped by dynamic braking.
If turning OFF the control power supply, but the SV_OFF command has not been received, the stopping method will vary with the SERVOPACK model. Two stopping methods are available.
• SERVOPACK models for servomotors that stop by coasting:
SGDV-330A and -550A
• SERVOPACK models for servomotors that stops by dynamic braking:
All SERVOPACKs other than those listed for coasting.
• If a coasting stop without decelerating is required when the main circuit power supply is turned OFF or the control power supply is turned OFF during operation without turning OFF the servo, use a SERVOPACK without a dynamic brake (SERVOPACK model digits 8 through 10 are 020).
• To minimize the coasting distance of the servomotor to come to a stop when an alarm occurs, the zero-speed stopping method is factory-set for alarms to which the zerospeed stop method is applicable. The DB stopping method may be more suitable than the zero-speed stopping method, however, depending on the application.
For example, for multiple axes coupling operation (a twin-drive operation), machinery damage may result if a zero-speed stop alarm occurs for one of the coupled shafts and the other shaft stops by dynamic brake. In such cases, change the method to the
DB stopping method.
(1) Stopping Method for Servomotor after SV_OFF Command is Received
Use Pn001.0 to select the stopping method for the servomotor after the SV_OFF command is received.
Pn001
Parameter n.
0
[Factory setting] n.
1 n.
2
DB
Stop Mode
Coast
Mode After Stopping When Enabled Classification
DB
After restart Setup
Coast
Coast
Note: Similar to the Coast Mode, the n.
0 setting (which stops the servomotor by dynamic braking and then holds it in Dynamic Brake Mode) does not generate any braking force when the servomotor stops or when it moves at very low speed.
4.3 Basic Functions Settings
(2) Stopping Method for Servomotor When an Alarm Occurs
There are two types of alarms (Gr.1 and Gr.2) that depend on the stopping method when an alarm occurs.
Select the stopping method for the servomotor when an alarm occurs using Pn001.0 and Pn00B.1.
The stopping method for the servomotor for a Gr.1 alarm is set to Pn001.0.
The stopping method for the servomotor for a Gr.2 alarm is set to Pn00B.1.
Refer to the information on alarm stopping methods in 8.1.1 List of Alarms .
Stopping Method for Servomotor for Gr.1 Alarms
The stopping method of the servomotor when a Gr.1 alarm occurs is the same as that in (1) Stopping Method for Servomotor after SV_OFF Command is Received .
Parameter Stop Mode
Mode After
Stopping n.
0
[Factory setting] n.
1 n.
2
DB
DB
Pn001
Coast
Coast
Coast
Stopping Method for Servomotor for Gr.2 Alarms
When Enabled
After restart
Classification
Setup
Pn00B
Parameter
Pn001 n.
0
[Factory setting] n.
0
[Factory setting] n.
1 n.
2 n.
1 n.
0
[Factory setting] n.
1 n.
2
Stop Mode
Zero-speed stopping
DB
DB
Mode After
Coast
DB
Coast
Stopping
When
Enabled
After restart
Classification
Setup
Coast
Note: The setting of Pn00B.1 is effective for position control and speed control. Pn00B.1 will be ignored for force control and only the setting of Pn001.0 will be valid.
4
4-15
4-16
4 Operation
4.3.6 Instantaneous Power Interruption Settings
4.3.6
Instantaneous Power Interruption Settings
Determines whether to continue operation or turn OFF the servomotor’s power when the power supply voltage to the SERVOPACK's main circuit is interrupted.
Pn509
Instantaneous Power Cut Hold Time
Setting Range
20 to 1000
Setting Unit
1 ms
Speed
Factory Setting
20
Position Force
When Enabled
Immediately
Classification
Setup
If the instantaneous power interruption time is equal to or lower than the set value in Pn509, the servomotor will continue to be powered. If the instantaneous power interruption time exceeds the set value in Pn509, the servomotor is not powered. The servomotor is turned ON when power supply to the main circuit recovers.
Set value for Pn509
≥
OFF time (t) Set value for Pn509 < OFF time (t)
Instantaneous power interruption Instantaneous power interruption
Main circuit power supply
OFF time (t)
Main circuit power supply
OFF time (t)
Set value for
Pn509
Servomotor status
Power ON
Set value for
Pn509 ≥ OFF time (t)
Operation continues.
Set value for
Pn509
Servomotor status
Instantaneous power interruption
Set value for
Pn509 < OFF time (t)
Power OFF
Power ON
Forced OFF
Instantaneous power interruption
<NOTE>
If the instantaneous power interruption time exceeds the set value in Pn509, the /S-RDY signal will be turned
OFF.
• The holding time of the control power supply for the 200-V SERVOPACKs is approximately 100 ms. The holding time of the control power supply for the 100-V SERVO-
PACKs is approximately 65 ms. If the control power supply makes control impossible during an instantaneous power interruption, the same operation will be performed as for normally turning OFF the power supply, and the setting of Pn509 will be ignored.
• The holding time of the main circuit power supply varies with the output of the SER-
VOPACK. If the load on the servomotor is large and an undervoltage alarm (A.410) occurs, the setting of Pn509 will be ignored.
• The holding time of the control power supply (24 VDC) for the 400-V SERVOPACKs depends on the capability of the power supply (not included). Check the power supply before using the application.
If the uninterruptible power supplies are used for the control power supply and main circuit power supply, the
SERVOPACK can withstand an instantaneous power interruption period in excess of 1000 ms.
4.3 Basic Functions Settings
4.3.7
Motor Maximum Speed
By setting a lower speed, the following effects can be obtained.
• More delicate speed control and more strict protection by generating the overspeed alarm (A.510)
• Allows the upper limit of Encoder Output Resolution (Pn281) to be set higher.
For details, refer to 4.4.4 Encoder Output Pulses .
Pn385
Motor Maximum Speed
Setting Range
1 to 100
Setting Unit
100 mm/s
Speed
Factory Setting
50
Position
Force
When Enabled
After restart
Classification
Setup
4
4-17
4-18
4 Operation
4.3.8 SEMI F47 Function (Force Limit Function for Low DC Power Supply Voltage for Main Circuit)
4.3.8
SEMI F47 Function (Force Limit Function for Low DC Power Supply Voltage for Main Circuit)
The force limit function detects an undervoltage warning and limits the output current if the DC power supply voltage for the main circuit in the SERVOPACK drops to a specified value because the power was momentarily interrupted or the power supply voltage for the main circuit was temporarily lowered.
This function complies with SEMI F47 standards for semiconductor production equipment.
Combining this function with the parameter for Instantaneous Power Cut Hold Time allows the servomotor to continue operating without stopping for an alarm or without recovery work even if the power supply voltage drops.
• This function is able to cope with instantaneous power interruptions in the voltage and time ranges stipulated in SEMI F47. An uninterruptible power supply (UPS) is required as a backup for instantaneous power interruptions that exceed these voltage and time ranges.
• This function is intended for voltage drops in the main circuit power supply. The following restrictions apply when it is used to provide an instantaneous power cut hold time in the control power supply. (There are no restrictions for the 200-VAC SERVO-
PACKs.)
<Control Power Supply Restrictions>
SERVOPACK with 400-VAC Power Input: Provide the control power supply from a 24-
VDC power supply that complies with SEMI F47 standards.
SERVOPACK with 100-VAC Power Input: Provide the control power supply from an uninterruptible power supply (UPS).
• Set the host controller and SERVOPACK force limit so that a force reference that exceeds the specified acceleration will not be output when the power supply for the main circuit is restored.
• Do not limit the force to values lower than the holding force for the vertical axis.
• This function limits force within the range of the SERVOPACK's capability when the power is cut. It is not intended for use under all load and operating conditions. Use the actual machine to set parameters while confirming correct operation.
• Setting the Instantaneous Power Cut Hold Time lengthens the amount of time from when the power supply is turned OFF until the motor current turns OFF. Send the
SV_OFF command to instantly stop the motor current.
4.3 Basic Functions Settings
(1) Execution Method
This function can be executed either with the host controller and the SERVOPACK or with the SERVOPACK only. Use Pn008.1 to specify whether the function is executed by the host controller and SERVOPACK or by the SERVOPACK only.
Execution with the Host Controller (Pn008 = n.
1 )
The host controller limits the force in response to an undervoltage warning.
The host controller removes the force limit after the undervoltage warning is cleared.
Main circuit input power supply
Main circuit bus voltage
280 V
*1
200 V
*2
Main circuit power interruption time
Main circuit bus voltage drops slowly because output force is limited.
SERVOPACK
Main circuit bus voltage increases by recovery of the main circuit power.
Undervoltage warning detected
Force limit starts.
Force limit
0%
Undervoltage warning
The force is limited in response to an undervoltage warning.
Host controller Force limit reference
Force limit ends.
0%
∗1.
560 V for 400-V power supply.
∗2.
400 V for 400-V power supply.
Execution with the SERVOPACK Only (Pn008 = n.
2 )
The force is limited in the SERVOPACK in response to an undervoltage warning.
The SERVOPACK controls the force limit value in the set time after the undervoltage warning is cleared.
Main circuit input power supply
SERVOPACK
Main circuit bus voltage
Undervoltage warning detected
280 V
*1
200 V
*2
Force limit starts.
Force limit
Setting value for Pn424
0%
∗1.
560 V for 400-V power supply.
∗2.
400 V for 400-V power supply.
Main circuit power interruption time
Main circuit bus voltage drops slowly because output force is limited.
Main circuit bus voltage increases by recovery of the main circuit power.
Setting value for Pn425
4
4-19
4-20
4 Operation
4.3.8 SEMI F47 Function (Force Limit Function for Low DC Power Supply Voltage for Main Circuit)
(2) Related Parameters
Pn008
Parameter n.
0
[Factory setting] n.
1 n.
2
Meaning
Does not detect undervoltage.
Detects warning and limits force by host controller.
Detects warning and limits force by Pn424 and Pn425.
(Only in the SERVOPACK)
When Enabled Classification
After restart Setup
Pn424
Pn425
Force Limit at Main Circuit Voltage Drop Speed
Setting Range
0 to 100
Setting Unit
1%*
Factory Setting
50
Release Time for Force Limit at Main Circuit Voltage
Drop
Setting Range Setting Unit
Speed
Factory Setting
0 to 1000 1 ms 100
Instantaneous Power Cut Hold Time
Pn509
Setting Range
20 to 1000
Setting Unit
1 ms
∗ The setting unit is a percentage of the rated force.
Note: When using SEMI F47 function, set 1000 ms.
Speed
Factory Setting
20
Position Force
When Enabled
Immediately
Position Force
When Enabled
Immediately
Position Force
When Enabled
Immediately
Classification
Setup
Classification
Setup
Classification
Setup
4.3 Basic Functions Settings
4.3.9
Setting Motor Overload Detection Level
In this SERVOPACK, the detection timing of the warnings and alarms can be changed by changing how to detect an overload warning (A.910) and overload (low load) alarm (A.720).
The overload characteristics and the detection level of the overload (high load) alarm (A.710) cannot be changed.
(1) Changing Detection Timing of Overload Warning (A.910)
The overload warning level is set by default to 20% so that an overload warning is detected in 20% of the time required to detect an overload alarm. The time required to detect an overload warning can be changed by changing the setting of the overload warning level (Pn52B). This protective function enables the warning output signal (/WARN) to serve as a protective function and to be output at the best timing for your system.
The following graph shows an example of the detection of an overload warning when the overload warning level (Pn52B) is changed from 20% to 50%. An overload warning is detected in half of the time required to detect an overload alarm.
Overload detection time
Detection curve of overload warning when
Pn52B=50%
Detection curve of overload alarm
Detection curve of overload warning when Pn52B=20% (factory setting)
100% 200% Force reference [%]
Note: For details, refer to Overload Characteristics listed in the section for the relevant servomotor in the uct Catalog (No.: KAEP S800000 42).
Σ -V Series Prod-
Pn52B
Overload Warning Level
Setting Range
1 to 100
Setting Unit
1%
Speed
Factory Setting
20
Position Force
When Enabled
Immediately
Classification
Setup
4
4-21
4-22
4 Operation
4.3.9 Setting Motor Overload Detection Level
(2) Changing Detection Timing of Overload (Low Load) Alarm (A.720)
An overload (low load) alarm (A.720) can be detected earlier to protect the servomotor from overloading. The time required to detect an overload alarm can be shortened by using the derated motor base current obtained with the following equation.
Note: The detection level of the overload (high load) alarm (A.710) cannot be changed.
Motor base current × Derating of base current at detecting overload of motor (Pn52C)
= Derated motor base current
Motor base current: Threshold value of motor current to start calculation for overload alarm
Derating of base current at detecting overload of motor (Pn52C): Derating of motor base current
The following graph shows an example of the detection of an overload alarm when Pn52C is set to 50%. The calculation for the overload of motors starts at 50% of the motor base current and then an overload alarm will be detected earlier.
Changing the setting of Pn52C will change the detection timing of the overload alarm, so the time required to detect the overload warning will also be changed.
Overload detection time
Detection curve of overload alarm when
Pn52C=100% (factory setting)
Detection curve of overload alarm when Pn52C=50%
50% 100% 200% Force reference [%]
Note: For details, refer to Overload Characteristics listed in the section for the relevant servomotor in the uct Catalog (No.: KAEP S800000 42).
Σ -V Series Prod-
Pn52C
Derating of Base Current at Detecting Overload of
Motor
Setting Range Setting Unit
Speed
Factory Setting
10 to 100 1% 100
Position Force
When Enabled
After restart
Classification
Setup
4.4 Trial Operation
4.4
Trial Operation
This section describes a trial operation using MECHATROLINK-II communications.
4.4.1
Inspection and Checking before Trial Operation
To ensure safe and correct trial operation, inspect and check the following items before starting trial operation.
(1) Servomotors
Inspect and check the following items, and take appropriate measures before performing trial operation if any problem exists.
• Are all wiring and connections correct?
• Are all nuts and bolts securely tightened?
Note: When performing trial operation on a servomotor that has been stored for a long period of time, perform the inspection according to the procedures described in 1.7 Servo Drive Maintenance and Inspection .
(2) SERVOPACKs
Inspect and check the following items, and take appropriate measures before performing trial operation if any problem exists.
• Are all wiring and connections correct?
• Is the correct power supply voltage being supplied to the SERVOPACK?
4
4-23
4-24
4 Operation
4.4.2 Trial Operation via MECHATROLINKII
4.4.2
Trial Operation via MECHATROLINK-
II
The following table provides the procedures for trial operation via MECHATROLINK-II.
Step
1
2
3
4
5
6
7
8
9
Description
Confirm that the wiring is correct, and then connect the I/O signal connector (CN1 connector).
Turn ON the power supply to the SERVOPACK.
If the SERVOPACK is receiving power, the CHARGE, the POWER, and the COM LED indicators on the SERVOPACK will light up.
Note: If the COM LED indicator does not turn ON, recheck the settings of MECHATROLINK-II setting switches (SW1 and SW2) and then turn the power supply to the SERVOPACK OFF and
ON again.
Reference
Chapter 3 Wiring and Connection
–
Send the CONNECT command.
In the response data from the SERVOPACK, the alarm code "00" is cleared to show normal operation.
The response data from the SERVOPACK may be confirmed with the
SMON command.
Check the product type using an ID_RD command.
A reply showing the product type, such as SGDV-R90A15A, is received from the SERVOPACK.
Set the following items to the necessary settings for a trial operation.
• Electronic gear settings
• Movement direction of servomotor
• Overtravel
Save these settings (step 5).
If saving the settings in the controller, use the PRM_WR command.
If saving settings in the SERVOPACK, use the PPRM_WR command.
Send the SV_ON command.
A reply showing that the servomotor has switched to Drive status and that SVON=1 (servomotor power is ON) is received.
Σ -V Series/
DC Power Input Σ -V Series/
Σ -V Series for Large-Capacity Models
User’s Manual
MECHATROLINK-II Commands
(No.: SIEP S800000 54)
4.4.3 Electronic Gear
4.3.1 Servomotor Movement Direction
4.3.2 Overtravel
Σ -V Series/
DC Power Input Σ -V Series/
Σ -V Series for Large-Capacity Models
User’s Manual
MECHATROLINK-II Commands
(No.: SIEP S800000 54)
Run the servomotor at low speed.
<Example using a positioning command>
Command used: POSING
Command setting: Option = 0, Positioning position =10000 (If using the absolute linear scale, add 10000 to the present position), rapid traverse speed= 400
Check the following points while running the servomotor at low speed
(step 8).
• Confirm that the movement direction of the servomotor correctly coincides with the forward movement or reverse movement reference.
If they do not coincide, reset the direction.
• Confirm that no unusual vibrations, noises, or temperature rises occur.
If any abnormalities are seen, correct the conditions.
Note: Because the running-in of the load machine is not sufficient at the time of the trial operation, the servomotor may become overloaded.
–
4.3.1 Servomotor Movement Direction
8.4 Troubleshooting Malfunction
Based on Operation and Conditions of the Servomotor
4.4 Trial Operation
4.4.3
Electronic Gear
The electronic gear enables the workpiece travel distance per reference unit input from the host controller. The minimum unit of the position data moving a load is called a reference unit.
The number of divisions on the serial converter unit: 256
When the Electronic Gear is Not Used When the Electronic Gear is Used
Linear scale
To move a workpiece 10 mm
The scale pitch is 20 μ m. Therefore,
10 ×
÷
× 256=128000 reference units
128000 reference units are input.
The equation must be calculated at the host controller.
Linear scale
Reference unit: 1 μ m
To move a workpiece 10 mm using reference units
1 reference unit is 1 μ m.
To move a workpiece 10 mm (10000 μ m),
1 reference unit = 1 μ m,
10000/1=10000 reference units.
Input 10000 reference units as reference input.
(1) Electronic Gear Ratio
Set the electronic gear ratio using Pn20E and Pn210.
Pn20E
Pn210
Electronic Gear Ratio (Numerator)
Setting Range
1 to 1073741824
Setting Unit
1
Electronic Gear Ratio (Denominator)
Setting Range
1 to 1073741824
Setting Unit
1
Factory Setting
4
Factory Setting
1
Position
When Enabled
After restart
Position
When Enabled
After restart
The electronic gear ratio to be set can be calculated by the following equation:
Classification
Setup
Classification
Setup
B
Electronic gear ratio:
A
=
Pn20E
Pn210
=
Travel distance per reference unit Number of divisions (See following table.)
Linear scale pitch
4
4-25
4-26
4 Operation
4.4.3 Electronic Gear
Feedback Resolutions of Linear Scale
The linear scale pitches and numbers of divisions are given in the following table.
Calculate the electronic gear ratio using the values in the following table.
Note: Set Pn282 to the linear scale pitch if you use a serial converter unit.
Pn282 is not valid when the linear scale is directly connected to the SERVOPACK and a serial converter unit is not used. Check the linear scale pitch on the Un084 and Un085 monitors.
Type of Linear Scale
Manufacturer
Heidenhain
Linear Scale Model
LIDA48
LIF48
Renishaw plc RGH22B
Incremental
Absolute
Magnescale Co., Ltd.
Magnescale Co., Ltd.
SR75 LF
*1
SR75 MF
SR85 LF
*1
SR85 MF
Heidenhain
SL700
*1
SL720
*1
, SL710
, SL730
*1
*1
,
LIC4100
Mitutoyo Corporation
ST781A/ST781AL
ST782A/ST782AL
ST783/ST783AL
ST784/ST784AL
ST788A/ST788AL
ST789A/ST789AL
*2
SR77 LF
*1
SR77 MF
SR87 LF
*1
SR87 MF
Linear
Scale
Pitch
[ μ m]
20
4
20
80
80
80
80
20.48
256
256
51.2
51.2
51.2
25.6
80
80
80
80
800
Model of Relay
Device between
SERVOPACK and
Linear Scale
–
PL101-RY
Number of
Divisions
Resolution
JZDP-D003 -E 256 0.078 μ m
JZDP-G003 -E 4096 0.0049 μ m
JZDP-D003 -E 256 0.016 μ m
JZDP-G003 -E 4096 0.00098 μ m
JZDP-D005 -E 256 0.078 μ m
JZDP-G005 -E 4096 0.0049 μ m
–
–
–
8192 0.0098 μ m
1024 0.078 μ m
8192 0.0098 μ m
1024 0.078 μ m
8192 0.0977 μ m
MJ620-T13
EIB3391Y
–
–
–
–
–
–
4096 0.005 μ m
512
512
0.5 μ m
0.5 μ m
512
512
512
0.1 μ m
0.1 μ m
0.1 μ m
512 0.05 μ m
–
–
–
–
8192 0.0098 μ m
1024 0.078 μ m
8192 0.0098 μ m
1024 0.078 μ m
∗1.
When using the encoder pulse output with these linear scales, the setting range of Pn281 is restricted. For details, refer to 4.4.5 Setting Encoder Output Pulse .
∗2.
For details on this linear scale, contact Mitutoyo.
Refer to the manuals for the linear scale and the serial converter unit for details on the scale pitch and the number of divisions on the linear scale.
Electronic gear ratio setting range: 0.001 ≤ Electronic gear ratio (B/A) ≤ 4000
If the electronic gear ratio is outside this range, a parameter setting error 1 (A.040) will be output.
(2) Electronic Gear Ratio Setting Examples
The following examples show electronic gear ratio settings for different load configurations.
Example: The number on divisions on the serial converter unit: 256
Step Operation
1 Check the scale pitch.
2 Determine the reference unit.
3 Calculate the electronic gear ratio.
4 Set parameters.
Load Configuration
0.02 mm (20 μ m)
1 reference unit: 0.001 mm (1 μ m)
B
=
1(
μ m)
A 20(
μ m)
×
256
Pn20E
Pn210
256
20
Refer to the following equation to determine the electric gear ratio.
Position reference
㧔 mm/P 㧕
B
A
+
−
Δ mm/P 㧕㧦 Reference unit
L 㧔 mm 㧕㧦 Movement distance
Ps 㧔 mm 㧕㧦 Scale pitch
Position loop
Speed loop
×
256
Servomotor
Movement distance L 㧔 mm 㧕
L
Ps mm/scale pitch 㧕
Δ
L
×
(
B
A
) = 256
×
(
B
A
) =
L
Ps
256
× L ×
Ps × L
Δ
=
256
×
Ps
Δ
Set A and B with the following parameters.
A 㧦 Pn210 B 㧦 Pn20E
4.4 Trial Operation
4
4-27
4-28
4 Operation
4.4.4 Encoder Output Pulses
4.4.4
Encoder Output Pulses
The encoder pulse output is a signal that is output from the linear scale and processed inside the SERVO-
PACK. It is then output externally in the form of two phase pulse signal (phases A and B) with a 90 ° phase differential. It is used as the position feedback to the host controller.
Signals and output phase form are as shown below.
(1) Signals
Type
Signal
Name
PAO
/PAO
PBO
Output
/PBO
Connector
Pin Number
CN1-17
CN1-18
CN1-19
CN1-20
Name
Encoder output pulse: phase A
Encoder output pulse: phase B
Remarks
The resolution of the pulse output from the SERVOPACK to the host controller is set in the parameter for the encoder output resolution
(Pn281). Phase A and phase B are different from each other in phase by an electric angle of 90 ° .
PCO
/PCO
CN1-21
CN1-22
Encoder output pulse: phase C
* −
∗ For details on the phase C, refer to (3) Encoder Output Pulse Signals from SERVOPACK with a Linear Scale by Renishaw plc .
SERVOPACK Host controller
CN2 CN1
Linear scale
ENC
Serial data
Serial converter unit Converts serial data to pulse.
Dividing circuit
(Pn281)
PAO
PBO
PCO
(2) Output Phase Form
Forward movement (phase B leads by 90 ° )
90°
Phase A
Phase B
Reverse movement (phase A leads by 90 ° )
90°
Phase A
Phase B
Phase C t
Phase C t
Note: The pulse width for phase C (origin pulse) changes according to the setting of the encoder output resolution (Pn281) and becomes the same as that for phase A.
Even in reverse movement mode (Pn000.0 = 1), the output phase form is the same as that for the standard setting
(Pn000.0 = 0) above.
4.4 Trial Operation
(3) Encoder Output Pulse Signals from SERVOPACK with a Linear Scale by Renishaw plc
The output position of the zero point signal (Ref) will depend on the direction of movement for some models of linear scale by Renishaw plc.
In such case, the phase-C pulses of the SERVOPACK are output at two positions.
For details on the specifications of the zero-point signals for a linear scale, refer to the manual for the Renishaw linear scale.
• Passing First Zero Point Signal (Ref) in Forward Direction and Returning after Power ON
Machine position
Zero point detection
position
Zero point
detection
position
Power ON
Zero point signal
㸦 Ref 㸧
Time
Phase C
No zero point signal (Ref) is sent from the linear scale.
However, a phase-C pulse will be sent from the SERVOPACK when moving in the reverse direction, because it is the same forward from which a phase-C pulse was sent from the
SERVOPACK when moving in a forward direction.
Second pulse is half as wide as the phase-A pulse.
• Passing First Zero Point Signal (Ref) in Reverse Direction and Returning after Power ON
Machine position
Zero point
detection
position
Zero point
detection
position
Power ON
Zero point signal
㸦 Ref 㸧
Time
Phase C
No zero point signal (Ref) is sent from the linear scale.
However, a phase-C pulse will be sent from the SERVOPACK when moving in the forward direction, because it is the same position from which a phase-C pulse was sent from the
SERVOPACK when moving in a reverse direction.
Second pulse is half as wide as the phase-A pulse.
4
4-29
4-30
4 Operation
4.4.4 Encoder Output Pulses
(4) Precautions When Using an Incremental Linear Scale by Magnescale
When an incremental linear scale by Magnescale Co., Ltd. is used, the count direction of the linear scale determines if a phase-C pulse (CN1-21, CN1-22) is output and counted.
Note: The count direction (counting up or down) of the linear scale determines if a phase-C pulse is output. The output of the pulse does not depend on the setting of the parameter: Pn000.0 (direction selection).
Model
SL710
SL720
SL730
SR75
SR85
Interpolator
PL101-RY
MJ620-T13
Scale pitch ( μ m)
800
800
800
80
80
Passing First Zero Point in Forward Direction and Returning after Power ON
When the zero point detection position is first passed in the forward direction after turning the power supply
OFF and ON again, the encoder dividing phase-C pulse (CN1-21 and CN1-22) is output. Then the encoder dividing phase-C pulse is output when the zero point detection position is passed in either the forward or reverse direction.
Scale count-up direction
Zero point detection position
Power ON
Time
Phase-C pulse output
The phase-C pulse is also output when the detection head of the linear scale passes this point in reverse, because the SERVOPACK has recorded the position where the phase-C pulse was originally output when first passing the position in the forward direction.
4.4 Trial Operation
Passing First Zero Point in Reverse Direction and Returning after Power ON
When the zero point detection position is first passed in the reverse direction after turning the power supply
OFF and ON again, the encoder dividing phase-C pulse (CN1-21 and CN1-22) is not output.
However, after the zero point detection position is passed in the forward direction and the encoder dividing phase-C pulse is output, the encoder dividing phase-C pulse is output even when the zero point detection position is passed in the reverse direction.
Scale count-up direction
Zero point detection position
Power ON
Time
Phase-C pulse output
The phase-C pulse is not output when passing the detection position in reverse direction first.
The phase-C pulse is also output when passing this point in reverse, because the SERVOPACK has recorded the position where the phase-C pulse was originally output when first passing the position in the forward direction.
Linear Scale with Multiple Zero Points and Passing First Zero Point in Forward Direction and Returning after Power ON
When you use a linear scale with multiple zero points, each zero point operates in the same manner as 4.4.4
(4) Passing First Zero Point in Reverse Direction and Returning after Power ON .
Scale count-up direction
Zero point 1 detection position
Zero point 2 detection position
Power ON
Time
Phase-C pulse output
Zero point 1 Zero point 1 Zero point 2
The phase-C pulse is also output when passing this point in reverse, because the SERVOPACK has recorded the position where the phase-C pulse was originally output when first passing the position in the forward direction.
Zero point 2
Even after zero point 1 has first been passed in the forward direction, the phase-C pulse is not output here because zero point 2 is passed in reverse direction.
4
4-31
4-32
4 Operation
4.4.4 Encoder Output Pulses
Linear Scale with Multiple Zero Points and Passing First Zero Point in Reverse Direction after Power ON
When you use a linear scale with multiple zero points, each zero point operates in the same manner as 4.4.4
(4) Passing First Zero Point in Reverse Direction and Returning after Power ON .
Scale count-up direction
Zero point 1 detection position
Zero point 2 detection position
Zero point 3 detection position
Power ON Time
Phase-C pulse output
Zero point 1 Zero point 3 Zero point 3
Phase-C pulse is not output when passing a zero point in reverse direction.
To output the encoder dividing phase-C pulse when moving in the reverse direction, set Pn081 to n.
1.
Pn081
Parameter n.
0
[Factory Setting] n.
1
Meaning
Outputs phase-C pulse only in forward direction.
Outputs phase-C pulse in forward and reverse direction.
When Enabled Classification
After restart Setup
Note: A SERVOPACK with software version 0023 or later supports this parameter.
<NOTE>
The encoder output pulse is output in the forward and reverse directions regardless of the setting of Pn081 when a serial converter unit is used.
4.4 Trial Operation
Setting of Pn081.0
Do not change the factory setting if the zero point position of the existing equipment must remain as is.
• When Pn081 is set to n.
1, the encoder dividing phase-C pulse output width may be narrower than the width of the phase-A pulse.
• As shown in the following diagram, there is a 1/8th scale pitch difference in the encoder dividing phase-C pulse output position, the zero point return command, and the phase-C detection position with the phase-C latch when Pn081 is set to n.
0 and when Pn081 is set to n.
1.
Moves to forward
1 scale pitch
Pn081 = n.
0
Zero point
1/8 scale pitch
Pn081 = n.
1
Zero point
4.4.5
Setting Encoder Output Pulse
Set the encoder output pulse using the following parameter.
Encoder Output Resolution
Setting Unit
1 edge/pitch
Speed
Factory Setting
20
Position Force
When Enabled
After restart
Classification
Pn281
Setting Range
1 to 4096 Setup
Note: The maximum setting for the encoder output resolution is 4096. When the number of divisions on the linear scale is more than 4096, the data shown in 4.4.3 (1) Feedback Resolutions of Linear Scale is no longer applicable.
Set the encoder output resolution for encoder pulse output signals (PAO, /PAO, PBO, /PBO) from the SER-
VOPACK to the host controller.
Feedback pulses per linear scale pitch or host controller.)
*
are divided inside the SERVOPACK by the value set in Pn281 (value after multiplication by 4) before being output. (Adjust the settings to the system specifications of the machine
The setting range depends on the servomotor’s maximum speed (Pn385) and linear scale pitch
The upper limit for Pn281 can be calculated with the following formula.
* .
Upper limit value for Pn281 =
Linear scale pitch*/100
Pn385
× 72
4
4-33
4-34
4 Operation
4.4.5 Setting Encoder Output Pulse
∗ The value depends on whether or not a serial converter unit is used.
Using a serial converter unit Value of Pn282
Not using a serial converter unit.
(When the linear scale and SERVOPACK are directly connected and when a linear scale that does not require a serial converter unit is used)
Value in the table in 4.4.3 (1) Feedback Resolutions of Linear
Scale .
In this case, the set value in Pn282 is ignored because the SERVO-
PACK automatically recognizes the linear scale pitch. The value of the automatically recognized linear scale pitch can be checked with
Un084 and Un085.
Note: When the scale pitch is 4 μ m, the motor maximum speed is limited to 1 ms/s because of the maximum response frequency of serial converter unit.
If the set value is out of the setting range or does not satisfy the setting conditions, the alarm "Encoder Output Pulse
Setting Error" (A.041) is output.
If the motor speed exceeds the upper limit value according to the set encoder output resolution, the alarm "Overspeed of Encoder Output Pulse Rate" (A.511) is output.
The upper limit of encoder output resolution is limited by the frequency dividing specification of serial converter unit.
Setting Example
When the linear scale pitch = 20 μ m and the motor maximum speed = 5 m/s (Pn385 = 50):
Pn281 = 28 is accepted, but Pn281 = 29 is not accepted and A.041 is output.
Output Example
When Pn281 = 20 (20-edge output (5-pulse output) per linear scale pitch),
Phase A
Phase B
Linear scale pitch (Pn282)
4.5 Test Without Motor Function
4.5
Test Without Motor Function
The test without a motor is used to check operation of the host controller and peripheral devices by simulating the operation of the servomotor in the SERVOPACK without actually operating the servomotor. This test enables you to check wiring, verify the system while debugging, and verify parameters. This shortens the time required for setup work and prevents damage to the machine that may result from possible malfunctions. This test can check the operation of the servomotor regardless of whether or not it is actually connected.
Reference
Host controller
SERVOPACK
Reference
Simulates the operation without motor.
48
Response Response
Use Pn00C.0 to enable or disable the test without a motor.
Pn00C
Parameter n.
0
[Factory setting] n.
1
Meaning
Disables the test without a motor.
Enables the test without a motor.
When
Enabled
After restart
Classification
Setup
4.5.1
Motor Information
The motor information that is used for a test without a motor is given below.
(1) When Motor is Connected
If a motor is connected, the information from the connected motor and the linear scale is used for the motor and linear scale information. The set value of Pn00C.2 is not used.
(2) When Motor is Not Connected
The information for the virtual motor and the linear scale that is stored in the SERVOPACK is used. The set value of Pn00C.2 is used for the linear scale information.
• Resolution: 256
• Scale pitch: The set value of Pn282
Encoder Type
The encoder information for the motor is set in Pn00C.2. A linear scale is always regarded as an incremental linear scale.
Parameter Meaning
When
Enabled
Classification
Pn00C n.
0
[Factory setting] n.
1
Sets an incremental linear scale as an encoder type for the test without a motor.
Sets an absolute linear scale as an encoder type for the test without a motor.
After restart Setup
Rated Motor Speed and Maximum Motor Speed
The values previously saved in the SERVOPACK will be used for the rated motor speed and maximum motor speed. Use the monitor displays (Un020: Motor rated speed and Un021: Motor maximum speed) to check the values.
4
4-35
4-36
4 Operation
4.5.2 Motor Position and Speed Responses
4.5.2
Motor Position and Speed Responses
For the test without a motor, the following responses are simulated for references from the host controller according to the gain settings for position or speed control.
• Servomotor position
• Servomotor speed
• Linear scale position
The load model, however, will be a rigid system with the mass ratio that is set in Pn103.
4.5.3
Limitations
The following functions cannot be used during the test without a motor.
• Regeneration and dynamic brake operation
• Brake output signal (The brake output signal can be checked with the I/O signal monitor function of the SigmaWin+.)
• Items marked with " × " in the following utility function table.
Fn No.
Contents
Fn000 Alarm history display
Fn002 JOG operation
Fn003 Origin search
Fn004 Program JOG operation
Fn005 Initializing parameter settings
Fn006 Clearing alarm history
Fn00C Offset adjustment of analog monitor output
Fn00D Gain adjustment of analog monitor output
Fn00E Automatic offset-signal adjustment of the motor current detection signal
Fn00F Manual offset-signal adjustment of the motor current detection signal
Fn010 Write prohibited setting
Fn011 Servomotor model display
Fn012 Software version display
Fn014 Resetting configuration error in option modules
Fn01B Vibration detection level initialization
Fn01E Display of SERVOPACK and servomotor ID
Fn020 Origin setting
Fn030 Software reset
Fn080 Polarity Detection
Fn200 Tuning-less levels setting
Fn201 Advanced autotuning
Fn202 Advanced autotuning by reference
Fn203 One-parameter tuning
Fn204 Anti-resonance control adjustment function
Fn205 Vibration suppression function
Fn206 EasyFFT
Fn207 Online vibration monitor
Note: : Can be used
× : Cannot be used
×
×
×
×
×
×
×
×
×
×
×
×
×
Can be used or not
Motor not connected
Motor connected
×
×
×
×
×
×
×
×
×
×
4.5 Test Without Motor Function
4.5.4
Digital Operator Displays during Testing without Motor
An asterisk ( ∗ ) is displayed before status display to indicate the test without a motor operation is in progress.
∗ B B − P R M / M O N
U n 0 0 0 = 0 0 0 0 0 0
−
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 8 = 0 0 0 0 0 0 0 0 0 0 0
U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0
(Example: Status of power to the servomotor is OFF)
*RUN
*BB
*P DET
*PT NT
Display
*P-OT
*N-OT
*HBB
Status
Power is supplied to the servomotor.
Power to the servomotor is OFF.
The polarity is being detected.
Forward or reverse run is prohibited.
Forward run is prohibited.
Reverse run is prohibited.
In hard-wire base block (safety) state.
Note: The test without a motor status is not displayed during alarm occurs (A.
).
4
4-37
4-38
4 Operation
4.6.1 Internal Force Limit
4.6
Limiting Force
The SERVOPACK provides the following four methods for limiting output force to protect the machine.
Limiting Method
Internal force limit
External force limit
Force limit with P_TLIM,
N_TLIM commands
*
Description
Always limits force by setting the parameter.
Limits force by input signal from the host controller.
Limit force by using the P_TLIM and N_TLIM commands.
Reference Section
4.6.1
4.6.2
–
Force limit with P_CL/N_CL signals of OPTION Field and
P_TLIM/N_TLIM commands
*
Combines force limit methods by using an external input and
P_TLIM and N_TLIM commands.
–
∗ For details, refer to the Σ -V Series/DC Power Input Σ -V Series/ Σ -V Series for Large-Capacity Models User’s Manual
MECHATROLINK-II Commands (Manual No.: SIEP S800000 54).
Note: The maximum force of the servomotor is used when the set value exceeds the maximum force.
4.6.1
Internal Force Limit
This function always limits maximum output force by setting values of following parameters.
Pn483
Pn484
Forward Force Limit
Setting Range
0 to 800
Reverse Force Limit
Setting Range
0 to 800
Setting Unit
1%
*
Speed
Factory Setting
30
Speed
Factory Setting
30
Position Force
When Enabled
Immediately
Position Force
When Enabled
Immediately
Classification
Setup
Classification
Setup
Setting Unit
1%
*
∗ Percentage (%) of rated motor force.
Note: If the settings of Pn483 and Pn484 are too low, the force may be insufficient for acceleration or deceleration of the servomotor.
Force waveform
No Internal Force Limit
(Maximum force can be output)
Internal Force Limit
Maximum force
Speed
Limiting force
Speed
Pn483 t t
Pn484
4.6 Limiting Force
4.6.2
External Force Limit
Use this function to limit force by inputting a signal from the host controller at specific times during machine operation. For example, some pressure must continually be applied (but not enough to damage the workpiece) when the robot is holding a workpiece or when a device is stopping on contact.
(1) Input Signals
Use the following input signals to limit a force by external force limit.
Type
Input
Input
Signal
Name
/P-CL
/N-CL
Connector
Pin Number
Setting
Must be allocated
Must be allocated
ON
(closed)
OFF
(open)
ON
(closed)
OFF
(open)
Meaning
Forward external force limit ON
Limit value
The smaller value of these settings: Pn483 or Pn404
Forward external force limit OFF Pn483
Reverse external force limit ON
The smaller value of these settings: Pn484 or Pn405
Reverse external force limit OFF Pn484
Note: Use parameter Pn50B.2 and Pn50B.3 to allocate the /P-CL signal and the /N-CL signal for use. For details, refer to
3.3.1 Input Signal Allocations .
(2) Related Parameters
Set the following parameters for external force limit.
Pn483
Pn484
Pn404
Pn405
Forward Force Limit
Setting Range
0 to 800
Setting Unit
1%
*
Reverse Force Limit
Setting Range
0 to 800
Setting Unit
1%
*
Forward External Force Limit
Setting Range
0 to 800
Setting Unit
1%
*
Reverse External Force Limit
Setting Range
0 to 800
Setting Unit
1%
*
Speed
Factory Setting
30
100
Speed
Factory Setting
30
Speed
Factory Setting
100
Speed
Factory Setting
Position Force
When Enabled
Immediately
Position Force
When Enabled
Immediately
Position Force
When Enabled
Immediately
Position Force
When Enabled
Immediately
Classification
Setup
Classification
Setup
Classification
Setup
Classification
Setup
∗ Percentage (%) of rated motor force.
Note: If the settings of Pn483, Pn484, Pn404, and Pn405 are too low, the force may be insufficient for acceleration or deceleration of the servomotor.
4
4-39
4-40
4 Operation
4.6.3 Checking Output Force Limiting during Operation
(3) Changes in Output Force during External Force Limiting
The following diagrams show the change in output force when the internal force limit is set to 800%.
In this example, the servomotor movement direction is Pn000.0 = 0 (Sets the linear scale counting up direction as the forward direction).
/P-CL
OFF ON
OFF
Pn483
0
Speed
Pn483
Pn404
0
Speed
Force Force
/N-CL
Pn484
Pn483
ON
0
Pn405
Pn484
Speed
Force
Pn484
Pn483
Pn404
0
Pn405
Pn484
Speed
Force
4.6.3
Checking Output Force Limiting during Operation
The following signal can be output to indicate that the servomotor output force is being limited.
Type Signal Name
Connector
Pin Number
Setting Meaning
Output /CLT Must be allocated
ON (closed)
OFF (open)
Servomotor output force is being limited.
Servomotor output force is not being limited.
Note: Use parameter Pn50F.0 to allocate the /CLT signal for use. For details, refer to 3.3.2 Output Signal Allocations .
4.7 Absolute Linear Scales
4.7
Absolute Linear Scales
If using an absolute linear scale, a system to detect the absolute position can be designed for use with the host controller. As a result, an operation can be performed without a zero point return operation immediately after the power is turned ON.
For details on how to set up the absolute linear scale, refer to 5 Trial Operation (Checking Linear Servomotor
Operation) in the Σ -V Series User’s Manual, Setup, Linear Motor (No.: SIEP S800000 44) .
Set Pn002 to n.
0 (factory setting) when you use an absolute linear scale.
Pn002
Parameter Meaning n.
0
[Factory setting] n.
1
Uses the absolute linear scale as an absolute linear scale.
Uses the absolute linear scale as an incremental linear scale.
When
Enabled
After restart
Classification
Setup
4.7.1
Absolute Data Request (SENS ON Command)
The Turn Encoder Power Supply ON command (SENS_ON) must be sent to obtain absolute data as an output from the SERVOPACK.
The SENS_ON command is sent at the following timing.
SERVOPACK control power supply
OFF
ON
5 seconds max.
ON (Normal status)
*
OFF
ALM signal OFF
(Alarm status)
SENS_ON
(Turn Encoder Power
Supply ON)
OFF
ON
OFF
OFF
OFF
Serial data
PAO
PBO
Undefined
Undefined
Initial incremental pulses
(Phase A)
Incremental pulses
(Phase A)
Initial incremental pulses
Incremental pulses
(Phase B) (Phase B)
ON
Servomotor power OFF OFF
60 ms max.
(90 ms typ.)
Approx.
15 ms 50 ms 400 ms max.
1 to 3 ms
The servomotor will not be turned ON even if the SV_ON command is received during this interval.
∗ Send the SENS_OFF command to turn OFF the control power supply.
4
4-41
4 Operation
4.7.2 Absolute Data Reception Sequence
4-42
4.7.2
Absolute Data Reception Sequence
The sequence in which the SERVOPACK receives outputs from the absolute linear scale and transmits them to host controller is shown below.
(1) Outline of Absolute Data
The serial data, pulses, etc., of the absolute linear scale that are output from the SERVOPACK are output from the PAO, PBO, and PCO signals as shown below.
SERVOPACK
Host controller
CN2 CN1
ENC
Serial data
Serial data→ pulse conversion
Dividing circuit
(Pn281)
PAO
PBO
PCO
Signal Name
PAO
PBO
PCO
Status
At initialization
Contents
Serial data
Initial incremental pulses
Normal Operations Incremental pulses
At initialization Initial incremental pulses
Normal Operations Incremental pulses
Always Origin pulses
Phase-C Output Specifications
The pulse width of phase C (origin pulse) changes depending on the encoder output resolution (Pn281), becoming the same width as phase A.
The output timing is one of the following.
• Synchronized with the rising edge of phase A
• Synchronized with the falling edge of phase A
• Synchronized with the rising edge of phase B
• Synchronized with the falling edge of phase B
Note: When host controller receives the data of absolute linear scale, do not perform counter reset using the output of PCO signal.
(2) Absolute Data Reception Sequence
1. Send the Turn Encoder Power Supply ON (SENS_ON) command from the host controller.
2. After 100 ms, the system is set to serial data reception standby and the incremental pulse up/down counter is cleared to zero.
3. Eight characters of serial data is received.
4. The system enters a normal incremental operation state about 400 ms after the last serial data is received.
SENS_ON
(Turn Encoder
Power Supply ON)
Serial data
PAO
PBO
Undefined
Undefined
Initial incremental pulses
(Phase A) (Phase A)
Incremental pulses
Initial incremental pulses
Incremental pulses
(Phase B) (Phase B)
50 ms
60 ms min.
90 ms typ.
Approx. 15 ms 400 ms max.
1 to 3 ms
<NOTE>
The output pulses are phase-B advanced if the servomotor is moving forward regardless of the setting in
Pn000.0.
4.7 Absolute Linear Scales
Serial data:
Outputs the current position as serial data after dividing using the value set at Pn281.
Unit: 1048576 pulse/serial data "1"
Initial incremental pulses:
Outputs the current position as pulse data after dividing using the value set at Pn281.
Pulse range: 0 to 1048576 pulse
Output pulse rate: Approx. 0.37 μ s
Coordinate
Value
M
O M
S
Value
0
0
1
Reference Position
1 (M s )
M
O
× R
2
2
3
Current Position
3 (M
O
)
P o
P
E
M
S
× R P
S P
M
Final absolute data P
M is calculated by following formula.
P
E
=M
O
× R+P
O
P
M
=P
E
− M
S
× R − P
S
Note: In the case of reverse direction mode (Pn000.0 = 1), use the above-mentioned formula.
Abbreviation
P
E
M
O
P
O
M
S
P
S
P
M
R
Meaning
Current value of linear scale
Serial data value at current position
Initial incremental pulses at current position
Serial data value at reference position
Initial incremental pulses at reference position
Current value required for the user’s system.
1048576
Note: When processing the absolute linear scale reception sequence, do not perform counter reset using PCO output.
4
4-43
4 Operation
4.7.2 Absolute Data Reception Sequence
(3) Serial Data Specifications and Initial Incremental Pulses
Serial Data Specifications
The serial data is output from PAO signal.
Start-stop Synchronization (ASYNC) Data Transfer
Method
Baud rate
Start bits
Stop bits
Parity
Character code
Data format
9600 bps
1 bit
1 bit
Even
ASCII 7-bit code
8 characters, as shown below.
"P"
"+" or " - "
"0" to "9"
Travel distance serial data, 5 digits
"CR"
4-44
0 0 0 0 0 1 0 1 0 1
Data Stop bit
Start bit Even parity
Note 1. The range for absolute data is "P+00000" (CR) or "P-00000" (CR).
2. The serial data range is "-32768" to "+32767". When this range is exceeded, the data changes from "+32767" to "-32678" or from "-32678" to "+32767".
3. In the case of reverse direction mode (Pn000.0 = 1), the sign reverses.
Initial Incremental Pulses
The initial incremental pulses are output after division inside the SERVOPACK in the same way as for normal incremental pulses. Refer to 4.4.4 Encoder Output Pulses for details.
(4) Transferring Alarm Contents
If an absolute linear scale is used, the contents of alarms detected by the SERVOPACK are transmitted in serial data to the host controller from the PAO output when the Turn Sensor OFF command (SENS_OFF) is received.
Note: The SENS_OFF command cannot be received while the servomotor power is ON.
Output example of alarm contents are as shown below.
Turn Encoder
Power Supply
OFF
(SENS_OFF)
Error detection
Encoder power supply ON
Encoder power supply OFF
Panel Display or
Overspeed
PAO Output
Incremental pulse
Enlarged view
Serial Data
Serial Data Format
A L M 5 1 .
CR "
Upper 2 digits
4.7 Absolute Linear Scales
4.7.3
Absolute Encoder Origin Offset
If using the absolute linear scale, the positions of the linear scale and the offset of the machine coordinate system (APOS) can be set. Use Pn808 to make the setting. After the SENS_ON command is received by
MECHATROLINK communications, this parameter will be enabled.
Pn808
Absolute Encoder Origin Offset
Setting Range
-1073741823 to
1073741823
Setting Unit
1 reference unit
Position
Factory Setting
When Enabled
0 Immediately
Classification
<Example>
If the linear scale position (X) is set at the origin of the machine coordinate system (0), Pn808 = X.
Setup
Origin
Machine coordinate system position
(APOS)
Linear scale position
Linear scale position: Origin
Pn808
Linear scale position
4
4-45
4 Operation
4.8.1 Servo Alarm Output Signal (ALM)
4.8
Other Output Signals
This section explains other output signals.
Use these signals according to the application needs, e.g., for machine protection.
4.8.1
Servo Alarm Output Signal (ALM)
This section describes signals that are output when the SERVOPACK detects errors and resetting methods.
(1) Servo Alarm Output Signal (ALM)
This signal is output when the SERVOPACK detects an error.
Configure an external circuit so that this alarm output turns OFF the main circuit power supply for the SERVOPACK whenever an error occurs.
4-46
Type
Output
Signal
Name
ALM
Connector
Pin Number
CN1-3, 4
Setting
ON (closed)
OFF (open)
Meaning
Normal SERVOPACK status
SERVOPACK alarm status
(2) Alarm Reset Method
If a servo alarm (ALM) occurs, use one of the following methods to reset the alarm after eliminating the cause of the alarm.
Be sure to eliminate the cause of the alarm before resetting it.
If the alarm is reset and operation continued without eliminating the cause of the alarm, it may result in damage to the equipment or fire.
Resetting Alarms by Sending Clear Warning or Alarm Command (ALM_CLR)
For details, refer to the Σ -V Series/DC Power Input Σ -V Series/ Σ -V Series for Large-Capacity Models User’s
Manual MECHATROLINK-II Commands (Manual No.: SIEP S800000 54).
Resetting Alarms Using the Digital Operator
Press the ALARM RESET Key on the digital operator. For details, refer to tion of Digital Operator (No.: SIEP S800000 55).
Σ -V Series User’s Manual, Opera-
4.8.2
Warning Output Signal (/WARN)
This signal is for a warning issued before the occurrence of an alarm.
Refer to 8.2.1 List of Warnings .
Signal Specifications
Type
Signal
Name
Connector Pin
Number
Setting Meaning
Output /WARN Must be allocated
ON (closed)
OFF (open)
Warning status
Normal status
Note: Use parameter Pn50F.3 to allocate the /WARN signal for use. For details, refer to 3.3.2 Output Signal Allocations .
4.8 Other Output Signals
4.8.3
Movement Detection Output Signal (/TGON)
This output signal indicates that the servomotor is moving at the speed set for Pn581 or a higher speed.
(1) Signal Specifications
Type
Signal
Name
Connector Pin
Number
Setting Meaning
Output /TGON Must be allocated
ON (closed)
OFF (open)
Servomotor is moving with the motor speed above the setting in Pn581.
Servomotor is moving with the motor speed below the setting in Pn581.
Note: Use parameter Pn50E.2 to allocate the /TGON signal for use. For details, refer to 3.3.2 Output Signal Allocations .
(2) Related Parameter
Set the range in which the /TGON signal is output using the following parameter.
Pn581
Zero Speed Level
Setting Range
1 to 10000
Setting Unit
1 mm/s
Speed
Factory Setting
20
Position Force
When Enabled
Immediately
Classification
Setup
4.8.4
Servo Ready Output Signal (/S-RDY)
This signal is turned ON when the SERVOPACK is ready to accept the servo ON (SV_ON) command.
The /S-RDY signal is turned ON under the following conditions.
• The main circuit power supply is ON.
• No hard wire base block state
• No servo alarms
• The Turn Encoder Power Supply ON (SENS_ON) command is received. (When an absolute linear scale is used.)
• Polarity detection has been completed. (When a servomotor without a hall sensor is used.) *
<NOTE>
• If an absolute linear scale is used, the output of absolute data to the host controller must have been completed when the SENS_ON command is received.
• For details on the hard wire base block function, refer to 4.9.1 Hard Wire Base Block (HWBB) Function .
∗ This condition does not apply to the first time the Servo ON (SV_ON) command is input after the control power supply is turned ON. The first time the Servo ON (SV_ON) command is input, polarity detection is started in sync with the command and the /S-RDY signal is turned ON after polarity detection is completed. A timing chart for polarity detection is given below.
Servo ON
(SV_ON) command
Servo OFF Servo ON
/S-RDY output 4
Polarity detection is being executed.
→
Status display: P-dt
Polarity detection completed.
→
Normal operation
of servomotor
4-47
4-48
4 Operation
4.8.4 Servo Ready Output Signal (/S-RDY)
Signal Specifications
Type
Signal
Name
Connector Pin
Number
Setting Meaning
Output /S-RDY Must be allocated
ON (closed)
OFF (open)
The SERVOPACK is ready to accept the SV_ON command.
The SERVOPACK is not ready to accept the
SV_ON command.
Note 1. Use parameter Pn50E.3 to allocate the /S-RDY signal for use. For details, refer to 3.3.2 Output Signal Allocations .
2. For details on the hard wire base block function and the servo ready output signal, refer to 4.9.1 Hard Wire Base
Block (HWBB) Function .
4.8 Other Output Signals
4.8.5
Speed Coincidence Output Signal (/V-CMP)
The speed coincidence output signal (/V-CMP) is output when the actual servomotor speed is the same as the reference speed. The host controller uses the signal as an interlock. This signal is the output signal during speed control.
Type
Signal
Name
Connector Pin
Number
Setting Meaning
Output /V-CMP Must be allocated
ON (closed)
OFF (open)
Speed coincides.
Speed does not coincide.
Note: Use parameter Pn50E.1 to allocate the /V-CMP signal for use. Refer to 3.3.2 Output Signal Allocations for details.
Speed Coincidence Signal Output Width
Setting Range
0 to 100
Setting Unit
1 mm/s
Speed
Factory Setting
10
Classification
Pn582
When Enabled
Immediately Setup
The /V-CMP signal is output when the difference between the reference speed and actual motor speed is below this setting.
Motor speed
Pn582
Reference speed
/V-CMP is output in this range.
<Example>
The /V-CMP signal is output at 1900 to 2100 mm/s if the Pn582 is set to 100 and the reference speed is 2000 mm/s.
4
4-49
4-50
4 Operation
4.8.6 Positioning Completed Output Signal (/COIN)
4.8.6
Positioning Completed Output Signal (/COIN)
This signal indicates that servomotor movement has been completed during position control.
When the difference between the number of references output by the host controller and the travel distance of the servomotor (position error) drops below the set value in the parameter, the positioning completion signal will be output.
Use this signal to check the completion of positioning from the host controller.
Type
Signal
Name
Output /COIN
Connector
Pin Number
Must be allocated
Setting
ON (closed)
OFF (open)
Meaning
Positioning has been completed.
Positioning is not completed.
Note: Use parameter Pn50E.0 to allocate the /COIN signal for use. Refer to 3.3.2 Output Signal Allocations for details.
Pn522
Positioning Completed Width
Setting Range
0 to 1073741824
Setting Unit
1 reference unit
Factory Setting
7
Position
When Enabled
Immediately
The positioning completed width setting has no effect on final positioning accuracy.
Reference
Motor speed
Motor speed
Classification
Setup
Position error
/COIN
Pn522
Time
Time
Time
Effective at ON (close).
Note: If the parameter is set to a value that is too large, a positioning completed signal might be output if the position error is low during a low speed operation. This will cause the positioning completed signal to be output continuously. If this signal is output unexpectedly, reduce the set value until it is no longer output.
If the position error is kept to a minimum when the positioning completed width is small, use Pn207.3 to change output timing for the /COIN signal.
Pn207
Parameter Name Meaning n.0
[Factory setting] n.1
n.2
/COIN Output
Timing
When the absolute value of the position error is below the positioning completed width (Pn522).
When the absolute value of the position error is below the positioning completed width (Pn522), and the reference after applying the position reference filter is 0.
When the absolute value of the position error is below the positioning completed width (Pn522), and the position reference input is 0.
When
Enabled
After restart
Classification
Setup
4.8 Other Output Signals
4.8.7
Positioning Near Output Signal (/NEAR)
Before confirming that the positioning completed signal has been received, the host controller first receives a positioning near signal and can prepare the operating sequence after positioning has been completed. The time required for this sequence after positioning can be shortened.
This signal is generally used in combination with the positioning completed output signal.
Type
Signal
Name
Connector
Pin Number
Setting Meaning
Output /NEAR Must be allocated
ON (closed)
OFF (open)
The servomotor has reached a point near to positioning completed.
The servomotor has not reached a point near to positioning completed.
Note: Use parameter Pn510.0 to allocate the /NEAR signal for use. Refer to 3.3.2 Output Signal Allocations for details.
NEAR Signal Width Position
Classification
Pn524
Setting Range
1 to 1073741824
Setting Unit
1 reference unit
Factory Setting
1073741824
When Enabled
Immediately Setup
The positioning near signal (/NEAR) is output when the difference between the number of references output by the host controller and the travel distance of the servomotor (position error) is less than the set value.
Motor speed Reference
Motor speed
Position error
0
/NEAR
/COIN
Pn524 Pn522 Time
Time
Time
Effective at ON (close).
Effective at ON (close).
Time
Note: Normally, the value of Pn524 should be larger than that for the positioning completed width (Pn522).
4
4-51
4-52
4 Operation
4.8.8 Speed Limit Detection Signal (/VLT)
4.8.8
Speed Limit Detection Signal (/VLT)
This function limits the speed of the servomotor to protect the machine.
A servomotor in force control is controlled to output the specified force, but the motor speed is not controlled.
Therefore, if an excessive reference force is set for the load force on the machinery side, the speed of the servomotor may increase greatly. If that may occur, use this function to limit the speed.
Note: The actual limit value of motor speed depends on the load conditions of the servomotor.
With No Speed Limit With Speed Limit
Motor speed
Maximum speed
Danger of damage due to critical speed.
Motor speed
Limiting speed
Safe operation with speed limit.
Time
Time
The parameters related to the speed limit, such as for selecting the speed limit method, are described next.
(1) Signals Output during Servomotor Speed Limit
The following signal is output when the motor speed reaches the limit speed.
Type
Signal
Name
Connector
Pin Number
Setting Meaning
Output /VLT Must be allocated
ON (closed)
OFF (open)
Servomotor speed limit being applied.
Servomotor speed limit not being applied.
Note: Use parameter Pn50F.1 to allocate the /VLT signal for use. For details, refer to 3.3.2 Output Signal Allocations .
(2) Speed Limit Setting
Select the speed limit mode with Pn002.1.
When
Enabled
Classification
Pn002
Parameter Meaning n.
0
[Factory setting] n.
1
VLIM (the speed limit value during force control) is not available. Uses the value set in Pn480 as the speed limit (internal speed limit function).
VLIM operates as the speed limit value (external speed limit function).
After restart Setup
4.8 Other Output Signals
Internal Speed Limit Function
If the internal speed limit function is selected in Pn002.1, set the limit of the maximum speed of the servomotor in Pn480. The limit of the speed in Pn408.1 can be either the maximum speed of the servomotor or the overspeed alarm detection speed. Select the overspeed alarm detection speed to limit the speed to the maximum speed of the servomotor or the equivalent.
Speed Limit During Force Control
Setting Unit
1 mm/s
Factory Setting
10000
Force
When Enabled
Immediately
Classification
Pn480
Setting Range
0 to 10000 Setup
Note: The servomotor’s maximum speed or the overspeed alarm detection speed will be used when the setting in this parameter exceeds the maximum speed of the servomotor used.
Parameter Meaning
When
Enabled
Classification
Pn408 n.
0
[Factory setting] n.
1
Uses the smaller value of the maximum motor speed and the value of Pn480 as the speed limit value.
Uses the smaller value of the overspeed alarm detection speed and the value of Pn480 as speed limit value.
After restart Setup
External Speed Limit Function
If the external speed limit mode is selected in Pn002.1, the motor speed is controlled by the speed limit value
(VLIM). For details, refer to the Σ -V Series/DC Power Input Σ -V Series/ Σ -V Series for Large-Capacity Models User’s Manual MECHATROLINK-II Commands (Manual No.: SIEP S800000 54).
4
4-53
4-54
4 Operation
4.9.1 Hard Wire Base Block (HWBB) Function
4.9
Safety Function
The safety function is incorporated in the SERVOPACK to reduce the risk associated with the machine by protecting workers from injury and by securing safe machine operation. Especially when working in hazardous areas inside the safeguard, as for machine maintenance, it can be used to avoid adverse machine movement.
4.9.1
Hard Wire Base Block (HWBB) Function
The Hard Wire Base Block function (hereinafter referred to as HWBB function) is a safety function designed to baseblock the servomotor (shut off the motor current) by using the hardwired circuits. Each circuit for two channel input signals blocks the run signal to turn off the power module that controls the motor current, and the motor current is shut off.
For the safety function signal connections, the input signal is the 0 V common and the output signal is the source output. This is opposite to other signals described in this manual. To avoid confusion, the ON and OFF status of signals for the safety functions are defined as follows:
ON: The state in which the relay contacts are closed or the transistor is ON and current flows into the signal line.
OFF: The state in which the relay contacts are open or the transistor is OFF and no current flows into the signal line.
The input signals are connected to the 0 V common. A connection example is provided in the following figure.
Power supply
24-V power supply
Switch
Fuse
0 V
/HWBB1+ 4
/HWBB1-
3
SERVOPACK
CN8
/HWBB2+
6
/HWBB2-
5
Control circuit
Run signal
Block
Block
Power module
Motor
4.9 Safety Function
(1) Risk Assessment
When using the HWBB function, be sure to perform a risk assessment of the servo system in advance. Make sure that the safety level of the standards is met. For details on the standards, refer to Harmonized Standards in the front of this manual.
Note: To meet the performance level d (PLd) in EN ISO 13849-1, the EDM signal must be monitored by a host controller.
If the EDM signal is not monitored by a host controller, the system only qualifies for the performance level c (PLc).
The following risks can be estimated even if the HWBB function is used. These risks must be included in the risk assessment.
• The servomotor will move in an application where external force is applied to the servomotor (for example, gravity on the vertical axis). Take measures to secure the servomotor, such as installing a mechanical brake.
• The servomotor may move within the electric angle of 180 degrees in case of the power module failure, etc.
Make sure that safety is ensured even in that situation. The movement distance depends on the motor type.
The maximum movement distance is given below.
Linear motor: 50 mm max.
• The HWBB function does not shut off the power to the SERVOPACK or electrically isolate it. Take measures to shut off the power to the SERVOPACK when performing maintenance on it.
(2) Hard Wire Base Block (HWBB) State
The SERVOPACK will be in the following state if the HWBB function operates. If the /HWBB1 or /HWBB2 signal is OFF, the HWBB function will operate and the SERVOPACK will enter a hard wire baseblock
(HWBB) state.
The HWBB function operates after the servomotor power is turned OFF.
/HWBB1
/HWBB2
ON
(Normal operation)
OFF
(Motor current shut-off request)
MII command
Status field
SVON
Motion command, etc.
1
SV_OFF command
0
SMON command, etc.
IO monitor field
HBB
0
SERVOPACK state
Operation BB state
1
HWBB state
The HWBB function operates while the servomotor power is ON.
/HWBB1
/HWBB2
MII command
Status field
SVON
ON
(Normal operation)
Motion command, etc.
1
OFF
(Motor current shut-off request)
SMON command, etc.
0
IO monitor field
HBB
SERVOPACK state
0
Operation
1
HWBB state
4
4-55
4-56
4 Operation
4.9.1 Hard Wire Base Block (HWBB) Function
(3) Resetting the HWBB State
Usually after the servo OFF command (SV_OFF: 32h) is received and the servomotor power is OFF, the SER-
VOPACK will then enter a hard wire baseblock (HWBB) state with the /HWBB1 and /HWBB2 signals turned
OFF. By then turning the /HWBB1 and /HWBB2 signals ON in this state, the SERVOPACK will enter a baseblock (BB) state and can accept the servo ON command (SV_ON: 31h).
OFF
/HWBB1
/HWBB2
(Motor current shut-off request)
ON
(Normal operation)
MII
Command
Status field
SVON
SMON
Command, etc.
0 0
SV_ON
Command
1
IO monitor field
HBB
1
1
HWBB state
0
0
BB state
0
Operation
0
SERVOPACK state
HWBB state BB state Operation
If the /HWBB1 and /HWBB2 signals are OFF and the servo ON command is received, the HWBB state will be maintained after the /HWBB1 and /HWBB2 signals are turned ON.
Send the servo OFF command, and the SERVOPACK is placed in a BB state. Then send the servo ON command again.
/HWBB1
/HWBB2
OFF
(Motor current shut-off request)
ON
(Normal operation)
MII
Command
SV_ON
Command
SV_OFF
Command
SV_ON
Command
Status field
SVON
0 0 1
IO monitor field
HBB
SERVOPACK state
Note: Even if the servomotor power is turned OFF by turning OFF the main circuit power, the HWBB status is retained until a servo OFF command is received.
4.9 Safety Function
(4) Related Commands
If the HWBB function is working with the /HWBB1 or /HWBB2 signal turned OFF, the setting of IO monitoring field D10 (HBB) changes to 1, so the status of the upper level apparatus can be known by looking at the setting of this bit.
If the status becomes HWBB status during the execution of the next command, a command warning is issued.
If a warning is given, clear the alarm to return to normal operational status. After stopping or canceling the action command, using the sequence of commands to return to the HWBB status is recommended.
Object Action Commands
Servo ON (SV_ON)
Interpolating (INTERPORATE)
Positioning (POSING)
Constant speed feed (FEED)
Interpolating with position detection function (LATCH)
External input positioning (EX_POSING)
Homing (ZRET)
(5) Error Detection in HWBB Signal
If only the /HWBB1 or /HWBB2 signal is input, an A.Eb1 alarm (Safety Function Signal Input Timing Error) will occur unless the other signal is input within 10 seconds. This makes it possible to detect failures, such as disconnection of the HWBB signals.
CAUTION
• The safety function signal input timing error alarm (A.Eb1) is not a safety-related part of a control system. Keep this in mind in the system design.
4
4-57
4-58
4 Operation
4.9.1 Hard Wire Base Block (HWBB) Function
(6) Connection Example and Specifications of Input Signals (HWBB Signals)
The input signals must be redundant. A connection example and specifications of input signals (HWBB signals) are shown below.
For safety function signal connections, the input signal is the 0 V common and the output signal is the source output. This is opposite to other signals described in this manual. To avoid confusion, the ON and OFF status of signals for safety functions are defined as follows:
ON: The state in which the relay contacts are closed or the transistor is ON and current flows into the signal line.
OFF: The state in which the relay contacts are open or the transistor is OFF and no current flows into the signal line.
Connection Example
24-V power supply
Fuse
Use a switch that has micro-current contacts.
0 V
Switch
SERVOPACK
CN8
/HWBB1+ 4
/HWBB1- 3
/HWBB2+
6
/HWBB2-
5
Specifications
Type
Signal
Name
Connector
Pin Number
Setting Meaning
Input
/HWBB1
/HWBB2
CN8-4
CN8-3
CN8-6
CN8-5
ON (closed) Does not use the HWBB function. (normal operation)
OFF (open)
Uses the HWBB function. (motor current shut-off request)
ON (closed) Does not use the HWBB function. (normal operation)
OFF (open)
Uses the HWBB function. (motor current shut-off request)
The input signals (HWBB signals) have the following electrical characteristics.
Items
Internal Impedance
Operation Movable Voltage Range
Maximum Delay Time
3.3 k Ω
Characteristics
+11 to + 25 V
20 ms
Remarks
−
−
Time from the /HWBB1 and /HWBB2 signals are OFF to the HWBB function operates.
If the HWBB function is requested by turning OFF the /HWBB1 and /HWBB2 input signals on the two channels, the power supply to the servomotor will be turned OFF within 20 ms (see below).
Within 20 ms
/HWBB1
/HWBB2
ON
(Normal operation)
OFF (Motor current shut-off request)
SERVOPACK
State
Normal operation HWBB state
Note 1. The OFF status is not recognized if the total OFF time of the /HWBB1 and /HWBB2 signals is 0.5 ms or shorter.
2. The status of the input signals can be checked using monitor displays. For details, refer to 7.5 Monitoring Safety
Input Signals .
4.9 Safety Function
(7) Operation with Utility Functions
The HWBB function works while the SERVOPACK operates in the utility function.
If any of the following utility functions is being used with the /HWBB1 and /HWBB2 signals turned OFF, the
SERVOPACK cannot be operated by turning ON the /HWBB1 and /HWBB2 signals. Cancel the utility function first, and then set the SERVOPACK to the utility function again and restart operation.
• JOG operation (Fn002)
• Origin search (Fn003)
• Program JOG operation (Fn004)
• Advanced autotuning (Fn201)
• EasyFFT (Fn206)
• Automatic offset-signal adjustment of motor current detection signal (Fn00E)
(8) Servo Ready Output (/S-RDY)
The servo ready output will turn OFF because the servo ON (SV_ON: 31 h) command cannot be accepted in the HWBB state.
The servo ready output will turn ON if the servomotor power is OFF (set to BB state) when both the /HWBB1 and /HWBB2 signals are ON.
The following diagram shows an example where the main circuit power supply is turned ON, the Turn
Encoder Power Supply ON (SENS_ON) command is sent (with an absolute linear scale), and no servo alarm occurs.
/HWBB1
/HWBB2
ON
(Normal operation)
OFF
(Motor current shut-off request)
ON
(Normal operation)
OFF
Servomotor
Power
ON
SERVOPACK
State Operating HWBB state BB state
/S-RDY
ON
OFF
ON
(9) Brake Signal (/BK)
When the /HWBB1 or /HWBB2 signal is OFF and the HWBB function operates, the brake signal (/BK) will turn OFF. At that time, Pn506 (brake reference - servo OFF delay time) will be disabled. Therefore, the servomotor may be moved by external force until the actual brake becomes effective after the brake signal (/BK) turns OFF.
CAUTION
• The brake signal is not a safety-related part of a control system. Be sure to design the system so that the system will not be put into danger if the brake signal fails in the HWBB state.
4
4-59
4-60
4 Operation
4.9.2 External Device Monitor (EDM1)
(10) Dynamic Brake
If the dynamic brake is enabled in Pn001.0 (Stopping Method for Servomotor after SV_OFF Command is
Received), the servomotor will come to a stop under the control of the dynamic brake when the HWBB function works while the /HWBB1 or /HWBB2 signal is OFF.
CAUTION
• The dynamic brake is not a safety-related part of a control system. Be sure to design the system so that the system will not be put into danger if the servomotor coasts to a stop in the HWBB state. Usually, use a sequence in which the HWBB state occurs after the servomotor is stopped using the reference.
• If the application frequently uses the HWBB function, do not use the dynamic brake to stop the servomotor. Otherwise element deterioration in the SERVOPACK may result. To prevent internal elements from deteriorating, use a sequence in which the HWBB state occurs after the servomotor has come to a stop.
(11) Servo Alarm Output Signal (ALM)
In the HWBB state, the servo alarm output signal (ALM) is not sent.
4.9.2
External Device Monitor (EDM1)
The external device monitor (EDM1) functions to monitor failures in the HWBB function. Connect the monitor to feedback signals to the safety function device.
Note: To meet the performance level d (PLd) in EN ISO13849-1, the EDM signal must be monitored by a host controller.
If the EDM signal is not monitored by a host controller, the system only qualifies for the performance level c (PLc).
Failure Detection Signal for EDM1 Signal
The relation of the EDM1, /HWBB1, and /HWBB2 signals is shown below.
Detection of failures in the EDM1 circuit can be checked using the following four status of the EDM1 signal in the table. Failures can be detected if the failure status can be confirmed, e.g., when the power supply is turned ON.
Signal
Name
/HWBB1
/HWBB2
EDM1
ON
ON
OFF
ON
OFF
OFF
Logic
OFF
ON
OFF
OFF
OFF
ON
WARNING
• The EDM1 signal is not a safety output. Use it only for monitoring a failure.
4.9 Safety Function
(1) Connection Example and Specifications of EDM1 Output Signal
Connection example and specifications of EDM1 output signal are explained below.
For safety function signal connections, the input signal is the 0 V common and the output signal is the source output. This is opposite to other signals described in this manual. To avoid confusion, the ON and OFF status of signals for safety functions are defined as follows:
ON: The state in which the relay contacts are closed or the transistor is ON and current flows into the signal line.
OFF: The state in which the relay contacts are open or the transistor is OFF and no current flows into the signal line.
Connection Example
EDM1 output signal is used for source circuit.
SERVOPACK
CN8
External device
8 EDM1+
24-V power supply
7 EDM1-
0 V
Specifications
Type
Output
Signal
Name
EDM1
Connector
Pin Number
CN8-8
CN8-7
Setting
ON (closed)
OFF (open)
Meaning
Both the /HWBB1 and the /HWBB2 signals are working normally.
The /HWBB1 signal, the /HWBB2 signal or both are not working normally.
Electrical characteristics of EDM1 signal are as follows.
Items
Maximum Allowable Voltage
Maximum Allowable Current
Maximum Voltage Drop at ON
Characteristics
30 VDC
50 mADC
1.0 V
Maximum Delay Time 20 ms
Remarks
−
−
Voltage between EDM1+ and EDM1- when current is 50 mA
Time from the change in /HWBB1 or /HWBB2 until the change in EDM1
4
4-61
4-62
4 Operation
4.9.3 Application Example of Safety Functions
4.9.3
Application Example of Safety Functions
An example of using safety functions is shown below.
(1) Connection Example
In the following example, a safety unit is used and the HWBB function operates when the guard opens.
Guard
Close
Limit switch
24-V power supply
Open
Fuse
Safety unit G9SX-BC202 manufactured by OMRON Corp.
A1
Power supply input
A2
T11 T12 T21 T22
Input
Reset/feedback input
T31 T32 T33
Output
S24 S14
CN8
/HWBB1+ 4
SERVOPACK
0 V
/HWBB1-
/HWBB2+
3
6
/HWBB2- 5
EDM1+ 8
EDM17
When a guard opens, both of signals, the /HWBB1 and the /HWBB2, turn OFF, and the EDM1 signal turns
ON. Since the feedback is ON when the guard closes, the safety unit is reset, and the /HWBB1 and the /
HWBB2 signals turn ON, and the operation becomes possible.
Note: The EDM1 signal is used as a sourcing output. Connect the EDM1 so that the current flows from EMD1+ to EMD1-.
(2) Failure Detection Method
In case of a failure such as the /HWBB1 or the /HWBB2 signal remains ON, the safety unit is not reset when the guard closes because the EDM1 signal keeps OFF. Therefore starting is impossible, then the failure is detected.
In this case, an error in the external device, disconnection or short-circuiting of the external wiring, or a failure in the SERVOPACK must be considered. Find the cause and correct the problem.
4.9 Safety Function
(3) Procedure
1 Request to open the guard.
2
When the servomotor is operating, the host controller stops the servomotor and sends the servo OFF command (SV_OFF).
3 Open the guard and enter.
4
The /HWBB1 and /HWBB2 signals are
OFF and HWBB function operates.
(The operation in the guard is available.)
5
After completing the operation, leave and close the guard.
6
The host controller sends the servo ON command (SV_ON).
4.9.4
Confirming Safety Functions
When starting the equipment or replacing the SERVOPACK for maintenance, be sure to conduct the following confirmation test on the HWBB function after wiring.
• Confirm that the SERVOPACK enters a hard wire base block state and that the servomotor does not operate when the /HWBB1 and /HWBB2 signals are OFF.
• Check the ON/OFF states of the /HWBB1 and /HWBB2 signals with Un015.
→ If the ON/OFF states of the signals do not coincide with the display, an error in the external device, disconnection or short-circuiting of the external wiring, or a failure in the SERVOPACK must be considered.
Find the cause and correct the problem.
• Check with the display of the feedback circuit input of the connected device to confirm that the EDM1 signal is OFF while in normal operation.
4
4-63
4 Operation
4.9.5 Safety Device Connections
4.9.5
Safety Device Connections
There are two types of the safety function’s jumper connectors that are attached to SERVOPACKs. You must remove a safety function’s jumper connector before connecting a safety function device. The connection method depends on the connector type that is used. Read the following procedures well before you attach a safety function device.
Connector Type A Connector Type B
Use the following procedures to attach safety function devices.
(1) Connector Type A
1.
SGDV-R70F, SGDV-R90F, SGDV-2R1F, SGDV-R70A, SGDV-R90A, SGDV-1R6A, SGDV-
2R8A, SGDV-1R9D, SGDV-3R5D, or SGDV-5R4D SERVOPACK
Disconnect the servomotor terminal connector while pressing in the servomotor terminal connector lock.
Enlarged View
1. Press in the lock.
2. Remove the servomotor
terminal connector while
pressing in the lock.
Lock
Servomotor terminal connector
When Using Any Other SERVOPACK
It is not necessary to remove the servomotor connection terminals. Proceed to step 2.
2.
Slide the lock injector on the safety function's jumper connector toward the SERVOPACK to unlock it and remove the safety function's jumper connector.
Enlarged View
1. Slide the lock injector
toward the SERVOPACK.
4-64
Lock injector
Safety function's jumper connector
2. Remove the safety function's jumper
connector while the lock injector is
slid toward the SERVOPACK.
Note: The safety function's jumper connector may be damaged if removed while the lock is still on.
4.9 Safety Function
3.
Connect the safety function device to the safety connector (CN8).
Note: If you do not connect a safety function device, leave the safety function's jumper connector connected to the safety connector (CN8). If the SERVOPACK is used without the safety function's jumper connector connected to CN8, no current will be supplied to the servomotor and no motor force will be output. In this case, the SERVOPACK will enter a hard wire base block state.
(2) Connector Type B
1.
Remove the safety function's jumper connector from the safety connector (CN8).
Enlarged View
C
N
1
C
N
2
C
N
8
C
N
8
C
N
2
Safety function’s jumper connector
Grab the safety function's jumper connector with the tips of your thumb and fingers and remove it.
2.
Connect the safety function device to the safety connector (CN8).
Note: If you do not connect a safety function device, leave the safety function's jumper connector connected to the safety connector (CN8). If the SERVOPACK is used without the safety function's jumper connector connected to CN8, no current will be supplied to the servomotor and no motor force will be output. In this case, the SERVOPACK will enter a hard wire base block state.
4.9.6
Precautions for Safety Functions
WARNING
• To check that the HWBB function satisfies the safety requirements of the system, be sure to conduct a risk assessment of the system.
Incorrect use of the machine may cause injury.
• The servomotor moves if there is external force (e.g., gravity in a vertical axis) when the HWBB function is operating. Therefore, use an appropriate device independently, such as a mechanical brake, that satisfies safety requirements.
Incorrect use of the machine may cause injury.
• While the HWBB function is operating, the motor may move within an electric angle of 180 ° or less as a result of a SERVOPACK failure. Use the HWBB function for applications only after checking that the movement of the motor will not result in a dangerous condition.
Incorrect use of the machine may cause injury.
• The dynamic brake and the brake signal are not safety-related parts of a control system. Be sure to design the system that these failures will not cause a dangerous condition when the HWBB function operates.
Incorrect use of the machine may cause injury.
• Connect devices meeting safety standards for the signals for safety functions.
Incorrect use of the machine may cause injury.
• The HWBB function does not shut off the power to the SERVOPACK or electrically isolate it. Take measures to shut off the power to the SERVOPACK when performing maintenance on it.
Failure to observe this warning may cause an electric shock.
4
4-65
5
Adjustments
5.1 Type of Adjustments and Basic Adjustment Procedure . . . . . . . . . . . . . . 5-3
5.1.1 Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
5.1.2 Basic Adjustment Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4
5.1.3 Monitoring Operation during Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5
5.1.4 Safety Precautions on Adjustment of Servo Gains . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-8
5.2 Tuning-less Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-10
5.2.1 Tuning-less Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-10
5.2.2 Tuning-less Levels Setting (Fn200) Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-13
5.2.3 Related Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-15
5.3 Advanced Autotuning (Fn201) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16
5.3.1 Advanced Autotuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16
5.3.2 Advanced Autotuning Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19
5.3.3 Related Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25
5.4 Advanced Autotuning by Reference (Fn202) . . . . . . . . . . . . . . . . . . . . . 5-26
5.4.1 Advanced Autotuning by Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-26
5.4.2 Advanced Autotuning by Reference Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-28
5.4.3 Related Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-32
5.5 One-parameter Tuning (Fn203) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-33
5.5.1 One-parameter Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-33
5.5.2 One-parameter Tuning Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-34
5.5.3 One-parameter Tuning Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-40
5.5.4 Related Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-42
5.6 Anti-Resonance Control Adjustment Function (Fn204) . . . . . . . . . . . . . 5-43
5.6.1 Anti-Resonance Control Adjustment Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-43
5.6.2 Anti-Resonance Control Adjustment Function Operating Procedure . . . . . . . . . . . . 5-44
5.6.3 Related Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-48
5.7 Vibration Suppression Function (Fn205) . . . . . . . . . . . . . . . . . . . . . . . . 5-49
5.7.1 Vibration Suppression Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-49
5.7.2 Vibration Suppression Function Operating Procedure . . . . . . . . . . . . . . . . . . . . . . . 5-50
5.7.3 Related Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-53
5
5-1
5-2
5 Adjustments
5.8 Additional Adjustment Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-54
5.8.1 Switching Gain Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-54
5.8.2 Manual Adjustment of Friction Compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-58
5.8.3 Current Control Mode Selection Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-60
5.8.4 Current Gain Level Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-60
5.8.5 Speed Detection Method Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-60
5.9 Compatible Adjustment Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-61
5.9.1 Feedforward Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-61
5.9.2 Mode Switch (P/PI Switching) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-62
5.9.3 Force Reference Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-64
5.9.4 Position Integral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-66
5.1 Type of Adjustments and Basic Adjustment Procedure
5.1
Type of Adjustments and Basic Adjustment Procedure
This section describes type of adjustments and the basic adjustment procedure.
5.1.1
Adjustments
Adjustments (tuning) are performed to optimize the responsiveness of the SERVOPACK.
The responsiveness is determined by the servo gain that is set in the SERVOPACK.
The servo gain is set using a combination of parameters, such as speed loop gain, position loop gain, filters, friction compensation, and mass ratio. These parameters influence each other. Therefore, the servo gain must be set considering the balance between the set values.
Generally, the responsiveness of a machine with high rigidity can be improved by increasing the servo gain. If the servo gain of a machine with low rigidity is increased, however, the machine will vibrate and the responsiveness may not be improved. In such case, it is possible to suppress the vibration with a variety of vibration suppression functions in the SERVOPACK.
The servo gains are factory-set to appropriate values for stable operation. The following utility function can be used to adjust the servo gain to increase the responsiveness of the machine in accordance with the actual conditions. With this function, parameters related to adjustment above will be adjusted automatically and the need to adjust them individually will be eliminated.
This section describes the following utility adjustment functions.
Utility Function for
Adjustment
Outline
Tuning-less
Levels Setting (Fn200)
Advanced Autotuning
(Fn201)
Advanced Autotuning by
Reference (Fn202)
One-parameter Tuning
(Fn203)
This function is enabled when the factory settings are used. This function can be used to obtain a stable response regardless of the type of machine or changes in the load.
The following parameters are automatically adjusted using internal references in the SERVOPACK during automatic operation.
• Mass ratio
• Gains (position loop gain, speed loop gain, etc.)
• Filters (force reference filter, notch filter)
• Friction compensation
• Anti-resonance control adjustment function
• Vibration suppression function
The following parameters are automatically adjusted with the position reference input from the host controller while the machine is in operation.
• Gains (position loop gain, speed loop gain, etc.)
• Filters (force reference filter, notch filter)
• Friction compensation
• Anti-resonance control adjustment function
• Vibration suppression function
The following parameters are manually adjusted with the position or speed reference input from the host controller while the machine is in operation.
• Gains (position loop gain, speed loop gain, etc.)
• Filters (force reference filter, notch filter)
• Friction compensation
• Anti-resonance control adjustment function
Anti-Resonance Control
Adjustment Function
(Fn204)
Vibration Suppression
Function (Fn205)
This function effectively suppresses continuous vibration.
This function effectively suppresses residual vibration if it occurs when positioning.
Applicable Control
Method
Speed and Position
Speed and Position
Position
Speed and Position
Speed and Position
Position
5
5-3
5-4
5 Adjustments
5.1.2 Basic Adjustment Procedure
5.1.2
Basic Adjustment Procedure
The basic adjustment procedure is shown in the following flowchart. Make suitable adjustments considering the conditions and operating requirements of the machine.
Start adjusting servo gain.
(1) Adjust using Tuning-less Function.
Runs the servomotor without any adjustments.
Refer to 5.2 Tuning-less Function .
Results OK?
Yes
Completed.
No
(2) Adjust using Advanced Autotuning.
Automatically adjusts the mass ratio, gains, and filters with internal references in the SERVOPACK.
Refer to 5.3 Advanced Autotuning (Fn201) .
Results OK?
Yes
Completed.
No
(3) Adjust using Advanced Autotuning by Reference.
Automatically adjusts gains and filters with user reference inputs.
Refer to 5.4 Advanced Autotuning by Reference (Fn202) .
Results OK?
Yes
Completed.
No
(4) Adjust using One-parameter Tuning.
Manually adjusts gains and filters.
Position loop gain, speed loop gain, filters, and friction compensation adjustments are available.
Refer to 5.5 One-parameter Tuning (Fn203) .
Results OK?
Yes
Completed.
No
Continuous vibration occurs.
Reduce the vibration using Anti-resonance Control Adjustment Function.
Refer to 5.6 Anti-Resonance Control Adjustment Function (Fn204) .
Residual vibration occurs at positioning.
Reduce the vibration using Vibration Suppression Function.
Refer to 5.7 Vibration Suppression Function (Fn205) .
No
Results OK?
Yes
Completed.
5.1 Type of Adjustments and Basic Adjustment Procedure
5.1.3
Monitoring Operation during Adjustment
Check the operating status of the machine and signal waveform when adjusting the servo gain. Connect a measuring instrument, such as a memory recorder, to connector CN5 analog monitor connector on the SERVO-
PACK to monitor analog signal waveform.
The settings and parameters for monitoring analog signals are described in the following sections.
(1) Connector CN5 for Analog Monitor
To monitor analog signals, connect a measuring instrument to connector CN5 with an analog monitor cable
(model: JZSP-CA01-E).
Connection Example
CN5
Line Color
White
Red
Black (2 lines)
CN5
JZSP-CA01-E
Black
Black
White
Red
Signal Name
Analog monitor 1
Analog monitor 2
GND
White
Black
Measuring
Probe
Red
Black
Probe GND
Measuring
Probe
Measuring
Instrument*
Probe GND
∗ You must acquire the measuring instrument separately.
Factory Setting
Force reference: 1 V/100% rated force
Motor speed: 1 V/1000 mm/s
Analog monitor GND: 0 V
(2) Monitor Signal
The shaded parts in the following diagram indicate analog output signals that can be monitored.
Force reference
Speed reference
Position reference
SERVOPACK
Speed feedforward Force feedforward
Position reference speed
Speed reference
+
Speed conversion
Position loop
Electronic gear
+
−
−
1
Electronic gear
Error counter
Position error
Positioning completed
Completion of position reference
Position amplifier error
Error counter
Kp
Motor speed
+
−
+
Speed conversion
Active gain
Speed loop
+ +
Force reference
Current loop
CN2
(U/V/W)
M Load
ENC
5
5-5
5-6
5 Adjustments
5.1.3 Monitoring Operation during Adjustment
The following signals can be monitored by selecting functions with parameters Pn006 and Pn007.
Pn006 is used for analog monitor 1 and Pn007 is used for analog monitor 2.
Parameter
Monitor Signal n.
00
[Pn007
Factory
Setting]
Motor moving speed n.
01 Speed reference n.
02
[Pn006
Factory
Setting]
Force reference n.
03 Position error
Pn006
Pn007 n.
04 Position amplifier error n.
05 Position reference speed n.
06 Reserved (Do not set.) n.
07 Reserved (Do not set.) n.
08 Positioning completed n.
09 Speed feedforward n.
0A Force feedforward n.
0B Active gain
* n.
0C Completion of position reference n.
0D Reserved (Do not set.)
Description
Unit
1 V/1000 mm/s
1 V/1000 mm/s
1 V/100% rated force
Remarks
−
−
−
0.05 V/1 reference unit 0 V at speed/force control
0.05 V/1 linear scale pulse unit
Position error after electronic gear conversion
1 V/1000 mm/s
−
−
Positioning completed:
5 V
Positioning not completed: 0 V
1 V/1000 mm/s
Completion indicated by output voltage.
−
−
−
1 V/100% rated force
1st gain: 1 V
2nd gain: 2 V
−
−
Gain type indicated by output voltage.
Completed: 5 V
Not completed: 0 V
−
Completion indicated by output voltage.
−
∗ Refer to 5.8.1 Switching Gain Settings for details.
(3) Setting Monitor Factor
The output voltages on analog monitors 1 and 2 are calculated by the following equations.
Analog monitor 1 output voltage = (-1)
×
Signal selection
(Pn006=n.00
غغ )
×
Multiplier + Offset voltage [V]
(Pn550)
Analog monitor 2 output voltage = (-1)
×
Signal selection
(Pn007=n.00
غغ )
(Pn552)
×
Multiplier + Offset voltage [V]
(Pn553) (Pn551)
5.1 Type of Adjustments and Basic Adjustment Procedure
<Example>
Analog monitor output at n.
00 (motor moving speed setting)
When multiplier is set to
×
1:
Analog monitor output voltage [V]
+6 V
When multiplier is set to
×
10:
Analog monitor output voltage [V]
+10 V (approx.)
+8 V
+6 V
-6000
+6000 Motor speed
[mm/s]
-800 -600
+600 +800 Motor speed
[mm/s]
-6 V
-6 V
-8 V
-10 V (approx.)
Note: Linear effective range: within
±
8 V
Output resolution: 16-bit
(4) Related Parameters
Use the following parameters to change the monitor factor and the offset.
Pn550
Pn551
Pn552
Pn553
Analog Monitor 1 Offset Voltage
Setting Range
-10000 to 10000
Setting Unit
0.1 V
Analog Monitor 2 Offset Voltage
Setting Range
-10000 to 10000
Setting Unit
0.1 V
Analog Monitor Magnification ( × 1)
Setting Range
-10000 to 10000
Setting Unit
× 0.01
Analog Monitor Magnification ( × 2)
Setting Range
-10000 to 10000
Setting Unit
× 0.01
Speed
Factory Setting
0
Speed
Factory Setting
0
Speed
Factory Setting
100
Speed
Factory Setting
100
Position Force
When Enabled
Immediately
Position Force
When Enabled
Immediately
Position Force
When Enabled
Immediately
Position Force
When Enabled
Immediately
Classification
Setup
Classification
Setup
Classification
Setup
Classification
Setup
5
5-7
5-8
5 Adjustments
5.1.4 Safety Precautions on Adjustment of Servo Gains
5.1.4
Safety Precautions on Adjustment of Servo Gains
CAUTION
• If adjusting the servo gains, observe the following precautions.
• Do not touch the moving section of the servomotor while power is being supplied to the motor.
• Before starting the servomotor, make sure that the SERVOPACK can come to an emergency stop at any time.
• Make sure that a trial operation has been performed without any trouble.
• Install a safety brake on the machine.
Set the following protective functions of the SERVOPACK to suitable settings before you start to adjust the servo gains.
(1) Overtravel Function
Set the overtravel function. For details on how to set the overtravel function, refer to 4.3.2 Overtravel .
(2) Force Limit
The force limit calculates the force required to operate the machine and sets the force limits so that the output force will not be greater than required. Setting force limits can reduce the amount of shock applied to the machine when troubles occur, such as collisions or interference. If a force limit is set lower than the value that is needed for operation, overshooting or vibration can be occurred.
For details, refer to 4.6 Limiting Force .
(3) Excessive Position Error Alarm Level
The excessive position error alarm is a protective function that will be enabled when the SERVOPACK is used in position control.
If this alarm level is set to a suitable value, the SERVOPACK will detect an excessive position error and will stop the servomotor if the servomotor does not operate according to the reference. The position error indicates the difference between the position reference value and the actual motor position.
The position error can be calculated from the position loop gain (Pn102) and the motor speed with the following equation.
Position Error [reference unit] =
Motor Speed [mm/s]
Pn102 [0.1/s]/10 *1, *2
×
Number of Divisions
Linear Scale Pitch [
μ m]/1000
• Excessive Position Error Alarm Level (Pn520 [1 reference unit])
×
Pn210
Pn20E
Pn520 >
Max. Motor Speed [mm/s]
Pn102 [0.1/s]/10 *1, *2
×
Number of Divisions
Linear Scale Pitch [ µ m]/1000
×
Pn210
Pn20E
× (1.2 to 2) *3
∗1.
When model following control is enabled (Pn140 = n.
1), use the set value in Pn141 and not in Pn102.
∗2.
To check the setting in Pn102, change the parameter display setting to display all parameters (Pn00B = n.
1).
∗3.
The underlined “(1.2 to 2)” portion is a factor that creates a margin so that a position error overflow alarm (A.d00) does not frequently occur.
Set the level to a value that satisfies these equations, and no position error overflow alarm (A.d00) will be generated during normal operation.
The servomotor will be stopped, however, if it does not operate according to the reference and the SERVO-
PACK detects an excessive position error.
If the acceleration/deceleration of the position reference exceeds the capacity of the servomotor, the servomotor cannot perform at the requested speed, and the allowable level for position error will be increased as not to satisfy these equations. If so, lower the level of the acceleration/deceleration for the position reference so that the servomotor can perform at the requested speed or increase the excessive position error alarm level
(Pn520).
5.1 Type of Adjustments and Basic Adjustment Procedure
Related Parameter
Pn520
Excessive Position Error Alarm Level
Setting Range
1 to 1073741823
Setting Unit
1 reference unit
Position
Factory Setting
5242880
When Enabled
Immediately
Classification
Setup
Related Alarm
Alarm
Display
A.d00
Alarm Name Meaning
Position Error Overflow Position errors exceeded parameter Pn520.
(4) Vibration Detection Function
Set the vibration detection function to an appropriate value with the vibration detection level initialization
(Fn01B). For details on how to set the vibration detection function, refer to 6.16 Vibration Detection Level
Initialization (Fn01B) .
(5) Excessive Position Error Alarm Level at Servo ON
If position errors remain in the error counter when turning ON the servomotor power, the servomotor will move and this movement will clear the counter of all position errors. Because the servomotor will move suddenly and unexpectedly, safety precautions are required. To prevent the servomotor from moving suddenly, select the appropriate level for the excessive position error alarm level at servo ON (Pn526) to restrict operation of the servomotor.
Related Parameters
Pn526
Excessive Position Error Alarm Level at Servo ON
Setting Range
1 to 1073741823
Setting Unit
1 reference unit
Position
Factory Setting
5242880
When Enabled
Immediately
Classification
Setup
Pn528
Excessive Position Error Warning Level at Servo ON
Setting Range
10 to 100
Setting Unit
1%
Position
Factory Setting
100
When Enabled
Immediately
Classification
Setup
Pn584
Speed Limit Level at Servo ON
Setting Range
0 to 10000
Setting Unit
1 mm/s
Position
Factory Setting
10000
When Enabled
Immediately
Classification
Setup
Related Alarms
Alarm
Display
Alarm Name Meaning
A.d01
A.d02
Position Error Overflow
Alarm at Servo ON
Position Error Overflow
Alarm by Speed Limit at
Servo ON
This alarm occurs if the servomotor power is turned ON when the position error is greater than the set value of Pn526 while the servomotor power is
OFF.
When the position errors remain in the error counter, Pn584 limits the speed if the servomotor power is turned ON. If Pn584 limits the speed in such a state, this alarm occurs when position references are input and the number of position errors exceeds the value set for the excessive position error alarm level (Pn520).
When an alarm occurs, refer to 8 Troubleshooting and take the corrective actions.
5
5-9
5-10
5 Adjustments
5.2.1 Tuning-less Function
5.2
Tuning-less Function
The tuning-less function is enabled in the factory settings. If resonance is generated or excessive vibration occurs, refer to 5.2.2 Tuning-less Levels Setting (Fn200) Procedure and change the set value of Pn170.2 for the rigidity level and the set value in Pn170.3 for the load level.
CAUTION
• The tuning-less function is enabled in the factory settings. A sound may be heard for a moment when the
SV_ON command is received for the first time after the servo drive is mounted to the machine. This sound does not indicate any problems; it means that the automatic notch filter was set. The sound will not be heard from the next time the SV_ON command is received. For details on the automatic notch filter, refer to (3) Automatically Setting the Notch Filter on the next page.
• The servomotor may vibrate if the mass of the load is 30 times greater or more than that of the servomotor in the mass ratio.
If vibration occurs, set the mode to 2 in Fn200 or lower the adjustment level.
5.2.1
Tuning-less Function
The tuning-less function obtains a stable response without manual adjustment regardless of the type of machine or changes in the load.
(1) Enabling/Disabling Tuning-less Function
The following parameter is used to enable or disable the tuning-less function.
Pn170
Parameter n.
0 n.
1
[Factory setting] n.
0
[Factory setting]
Meaning
Disables tuning-less function.
Enables tuning-less function.
Used as speed control. n.
1
Used as speed control and host controller used as position control.
When Enabled Classification
After restart Setup
(2) Application Restrictions
The tuning-less function can be used in position control or speed control. This function is not available in force control. The following application restrictions apply to the tuning-less function.
Function
Vibration detection level initialization
(Fn01B)
Availability
Available
Remarks
–
Advanced autotuning (Fn201)
Advanced autotuning by reference (Fn202)
One-parameter tuning (Fn203)
Anti-resonance control adjustment function (Fn204)
Vibration suppression function (Fn205)
Available
(Some conditions apply)
Not available
Not available
• Execute this function when mass (Jcalc =
ON) is set.
• The tuning-less function is disabled while
Fn201 is being executed. It remains disabled after Fn201 is completed.
–
–
Not available
Not available
EasyFFT (Fn206)
Friction compensation
Gain switching
Available
Not available
Not available
–
–
While this function is being used, the tuningless function cannot be used. After completion of the EasyFFT, it can be used again.
–
–
5.2 Tuning-less Function
Function
Offline mass calculation *
Mechanical analysis*
Availability
Not available
Available
(cont’d)
Remarks
Disable the tuning-less function by setting
Pn170.0 to 0 before executing this function.
While this function is being used, the tuningless function cannot be used. After completion of the analysis, it can be used again.
∗ Operate using SigmaWin+.
(3) Automatically Setting the Notch Filter
Usually, set this function to Auto Setting. (The notch filter is factory-set to Auto Setting.)
If this function is set to Auto Setting, vibration will be detected automatically and the notch filter will be set when the tuning-less function is enabled.
Set this function to Not Auto Setting only if you do not change the notch filter setting before executing tuningless function.
Pn460
Parameter n.
0 n.
1
[Factory setting]
Meaning
Does not set the 2nd notch filter automatically with utility function.
Set the 2nd notch filter automatically with utility function.
When Enabled Classification
Immediately Tuning
Always set Pn460.2 to 0 in the following cases.
• Mechanism that produces a large disturbance (such as guides)
• When using force limits
• When the speed references are step inputs
If you set Pn460.2 to 1, vibration detection may not operate effectively.
(4) Tuning-less Level Settings
Two tuning-less levels are available: the rigidity level and load level. Both levels can be set in the Fn200 utility function or in the Pn170 parameter.
Rigidity Level a) Using the utility function
To change the setting, refer to 5.2.2 Tuning-less Levels Setting (Fn200) Procedure .
Digital Operator Display
Level 0
Level 1
Level 2
Level 3
Level 4 [Factory setting]
Rigidity level 0
Rigidity level 1
Rigidity level 2
Rigidity level 3
Rigidity level 4
Meaning b) Using the parameter
Pn170
Parameter n.
0 n.
1 n.
2 n.
3 n.
4
[Factory setting]
Meaning
Rigidity level 0 (Level 0)
Rigidity level 1 (Level 1)
Rigidity level 2 (Level 2)
Rigidity level 3 (Level 3)
Rigidity level 4 (Level 4)
When Enabled Classification
Immediately Setup
5
5-11
5-12
5 Adjustments
5.2.1 Tuning-less Function
Load Level a) Using the utility function
To change the setting, refer to 5.2.2 Tuning-less Levels Setting (Fn200) Procedure .
Digital Operator Display
Mode 0
Mode 1 [Factory setting]
Mode 2
Load level: Low
Load level: Medium
Load level: High
Meaning b) Using the parameter
Pn170
Parameter n.0
Meaning
Load level: Low (Mode 0) n.1
[Factory setting] Load level: Medium (Mode 1) n.2
Load level: High (Mode 2)
When Enabled Classification
Immediately Setup
5.2 Tuning-less Function
5.2.2
Tuning-less Levels Setting (Fn200) Procedure
CAUTION
• To ensure safety, perform the tuning-less function in a state where the SERVOPACK can come to an emergency stop at any time.
The procedure to use the tuning-less function is given below.
Operate the tuning-less function from the digital operator (option) or SigmaWin+.
For the basic operation of the digital operator, refer to tor (No.: SIEP S800000 55).
Σ -V Series User’s Manual, Operation of Digital Opera-
(1) Preparation
Check the following settings before performing the tuning-less function. If the settings are not correct, "NO-
OP" will be displayed during the tuning-less function.
• The tuning-less function must be enabled (Pn170.0 = 1).
• The write prohibited setting (Fn010) must be set to Write permitted (P.0000).
• The test without a motor function must be disabled. (Pn00C.0 = 0).
(2) Operating Procedure with Digital Operator
Keys Step
1
Display after Operation
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧜㧤㧜㧦㧼㨛㨘㨑ޓ㧰㨑㨠㨑㨏㨠
㧲㨚㧞㧜㧜㧦㨀㨡㨚㨑㧸㨢㨘ޓ㧿㨑㨠
㧲㨚㧞㧜㧝㧦㧭㧭㨀
㧲㨚㧞㧜㧞㧦㧾㨑㨒㧙㧭㧭㨀
2
㧾㨁㧺 ̆㨀㨡㨚㨑㧸㨢㨘㧿㨑㨠̆
ޓ㧹㨛㨐㨑㧩
3
㧾㨁㧺 ̆㨀㨡㨚㨑㧸㨢㨘㧿㨑㨠̆
ޓ㧸㨑㨢㨑㨘㧩㧠
4
㧾㨁㧺 ̆㨀㨡㨚㨑㧸㨢㨘㧿㨑㨠 ̆
ޓ㧸㨑㨢㨑㨘㧩㧠
ޓޓޓޓޓ㧺㧲㧞
2nd notch filter
5
㧾㨁㧺 ̆㨀㨡㨚㨑㧸㨢㨘㧿㨑㨠̆
ޓ㧸㨑㨢㨑㨘㧩㧠
Operation
Press the Key to view the main menu for the utility function.
Use the or Key to move through the list, select Fn200.
Press the key to display the load level setting screen for Fn200 (Tuning-less Levels Setting).
Notes:
• If the response waveform causes overshooting or if the mass of the load is 30 times greater or more than that of the servomotor in the mass ratio (i.e., outside the scope of product guarantee), press the
Key and change the mode setting to 2.
• If a high-frequency noise is heard, press the
Key and change the mode setting to 0.
Press the Key to display the rigidity level of the tuning-less mode setting screen.
Press the Key or the ity level.
Key to select the rigid-
Select the rigidity level from 0 to 4. The larger the value, the higher the gain is and the better response performance will be. (The factory setting is 4.)
Notes:
• Vibration may occur if the rigidity level is too high.
Lower the rigidity level if vibration occurs.
• If a high-frequency noise is heard, press the
Key to automatically set a notch filter to the vibration frequency.
Press the Key. “DONE” will flash for approximately two seconds and then “RUN” will be displayed. The settings are saved in the SERVOPACK.
5
5-13
5-14
5 Adjustments
5.2.2 Tuning-less Levels Setting (Fn200) Procedure
(cont’d)
Step Display after Operation Keys Operation
6
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧜㧟㧜
㧲㨚㧞㧜㧜
㧲㨚㧞㧜㧝
㧲㨚㧞㧜㧞
Press the Key to complete the tuning-less function. The screen in step 1 will appear again.
Note: If the rigidity level is changed, the automatically set notch filter will be canceled. If vibration occurs, however, the notch filter will be set again automatically.
(3) Alarm and Corrective Actions
The autotuning alarm (A.521) will occur if resonance sound is generated or excessive vibration occurs during position control. In such case, take the following actions.
Resonance Sound
Reduce the setting of the rigidity level or load level.
Excessive Vibration during Position Control
Take one of the following actions to correct the problem.
• Increase the setting of the rigidity level or reduce the load level.
• Increase the setting of Pn170.3 or reduce the setting of Pn170.2.
(4) Parameters Disabled by Tuning-less Function
When the tuning-less function is enabled in the factory settings, the settings of these parameters are not available: Pn100, Pn101, Pn102, Pn103, Pn104, Pn105, Pn106, Pn160, Pn139, and Pn408. These gain-related parameters, however, may become effective depending on the executing conditions of the functions specified in the following table. For example, if EasyFFT is executed when the tuning-less function is enabled, the settings in Pn100, Pn104, Pn101, Pn105, Pn102, Pn106, and Pn103, as well as the manual gain switch setting, will be enabled, but the settings in Pn408.3, Pn160.0, and Pn139.0 will be not enabled .
Item
Parameters Disabled by Tuning-less Function
Name Pn Number
Related Functions and Parameters*
Force Control
Easy
FFT
Mechanical
Analysis (Vertical Axis
Mode)
Gain
Advanced
Control
Speed Loop Gain
2nd Speed Loop Gain
Speed Loop Integral Time Constant
2nd Speed Loop Integral Time Constant
Position Loop Gain
2nd Position Loop Gain
Mass Ratio
Friction Compensation Function Selection
Anti-resonance Control Adjustment
Selection
Gain Switching
Gain Switching Selection Switch
∗ : Parameter enabled
× : Parameter disabled
Pn100
Pn104
Pn101
Pn105
Pn102
Pn106
Pn103
Pn408.3
Pn160.0
Pn139.0
×
×
×
×
×
×
×
×
×
×
×
5.2 Tuning-less Function
(5) Tuning-less Function Type
The following table shows the types of tuning-less functions for the version of SERVOPACK software.
Software Version*
000A or earlier
000B or later
Tuning-less Type
Tuning-less type 1
Tuning-less type 2
Meaning
−
The level of noise produced is lower than that of Type 1.
∗ The software version number of your SERVOPACK can be checked with Fn012.
Pn14F
Parameter n.
0 n.
1
[Factory setting]
Tuning-less type 1
Tuning-less type 2
Meaning
Parameter
Pn170
Pn401
Pn40C
Pn40D
Name
Tuning-less Function Related Switch
Force Reference Filter Time Constant
2nd Notch Filter Frequency
2nd Notch Filter Q Value
When Enabled Classification
After restart Tuning
5.2.3
Related Parameters
The following table lists parameters related to this function and their possibility of being changed while executing this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes : Parameters can be changed using SigmaWin+ while this function is being executed.
No : Parameters cannot be changed using SigmaWin+ while this function is being executed.
• Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
Mid-execution changes
No
No
No
No
Automatic changes
Yes
Yes
Yes
Yes
5
5-15
5 Adjustments
5.3.1 Advanced Autotuning
5-16
5.3
Advanced Autotuning (Fn201)
This section describes the adjustment using advanced autotuning.
• Advanced autotuning starts adjustments based on the set speed loop gain (Pn100).
Therefore, precise adjustments cannot be made if there is vibration when starting adjustments. In this case, make adjustments after lowering the speed loop gain
(Pn100) until vibration is eliminated.
• Before performing advanced autotuning with the tuning-less function enabled
(Pn170.0 = 1: Factory setting), always set Jcalc to ON to calculate the mass. The tuning-less function will automatically be disabled, and the gain will be set by advanced autotuning.
With Jcalc set to OFF so the mass is not calculated, "Error" will be displayed on the panel operator, and advanced autotuning will not be performed.
• If the operating conditions, such as the machine-load or drive system, are changed after advanced autotuning, then change the following related parameters to disable any values that were adjusted before performing advanced autotuning once again with the setting to calculate the mass (Jcalc = ON). If advanced autotuning is performed without changing the parameters, machine vibration may occur, resulting in damage to the machine.
Pn00B.0=1 (Displays all parameters.)
Pn140.0=0 (Does not use model following control.)
Pn160.0=0 (Does not use anti-resonance control.)
Pn408=n.00
0 (Does not use friction compensation, 1st notch filter, or 2nd notch filter.)
5.3.1
Advanced Autotuning
Advanced autotuning automatically operates the servo system (in reciprocating movement in the forward and reverse directions) within set limits and adjust the SERVOPACK automatically according to the mechanical characteristics while the servo system is operating.
Advanced autotuning can be performed without connecting the host controller.
The following automatic operation specifications apply.
• Maximum speed: Rated motor speed × 2/3
• Acceleration force: Approximately 100% of rated motor force
The acceleration force varies with the influence of the mass ratio (Pn103), machine friction, and external disturbance.
• Travel distance: Set in unit of 1000 reference unit. Factory setting is 90 mm.
Movement
Speed
Rated motor speed
×
2/3 t: time
SERVOPACK
Reference
Response
Execute advanced autotuning after a JOG operation to move the position to ensure a suitable movement range.
Travel distance
Advanced autotuning performs the following adjustments.
• Mass ratio
• Gains (e.g., position loop gain and speed loop gain)
• Filters (force reference filter and notch filter)
• Friction compensation
Rated motor speed
×
2/3
Rated motor force
Approx. 100%
Rated motor force
Approx. 100%
Automatic operation t: time
5.3 Advanced Autotuning (Fn201)
• Anti-resonance control
• Vibration suppression (Mode = 2 or 3)
Refer to 5.3.3 Related Parameters for parameters used for adjustments.
CAUTION
• Because advanced autotuning adjusts the SERVOPACK during automatic operation, vibration or overshooting may occur. To ensure safety, perform advanced autotuning in a state where the SERVOPACK can come to an emergency stop at any time.
(1) Preparation
Check the following settings before performing advanced autotuning.
The message “NO-OP” indicating that the settings are not appropriate will be displayed, if all of the following conditions are not met.
• The main circuit power supply must be ON.
• There must be no overtravel.
• The servomotor power must be OFF.
• The control method must not be set to force control.
• The gain selection switch must be in manual switching mode (Pn139.0 = 0).
• Gain setting 1 must be selected.
• The test without a motor function must be disabled (Pn00C.0 = 0).
• All alarms and warning must be cleared.
• The hardwire baseblock (HWBB) must be disabled.
• The write prohibited setting (Fn010) must be set to Write permitted (P.0000).
• Jcalc must be set to ON to calculate the mass when the tuning-less function is enabled (Pn170.0 = 1: factory setting) or the tuning-less function must be disabled (Pn170.0 = 0).
Note:
• If advanced autotuning is started while the SERVOPACK is in speed control, the mode will change to position control automatically to perform advanced autotuning. The mode will return to speed control after completing the adjustment. To perform advanced autotuning in speed control, set the mode to 1 (Mode = 1).
(2) When Advanced Autotuning Cannot Be Performed
Advanced autotuning cannot be performed normally under the following conditions. Refer to 5.4 Advanced
Autotuning by Reference (Fn202) and 5.5 One-parameter Tuning (Fn203) for details.
• The machine system can work only in a single direction.
• The operating range is 5 mm or less.
(3) When Advanced Autotuning Cannot Be Performed Successfully
Advanced autotuning cannot be performed successfully under the following conditions. Refer to 5.4
Advanced Autotuning by Reference (Fn202) and 5.5 One-parameter Tuning (Fn203) for details.
• The operating range is not applicable.
• The mass changes within the set operating range.
• The machine has high friction.
• The rigidity of the machine is low and vibration occurs when positioning is performed.
• The position integration function is used.
• P control operation (proportional control) is used.
Note: If a setting is made for calculating the mass, an error will result when P control operation is selected using /V_PPI of OPTION field while the mass is being calculated.
• The mode switch is used.
Note: If a setting is made for calculating the mass, the mode switch function will be disabled while the mass is being calculated. At that time, PI control will be used. The mode switch function will be enabled after calculating the mass.
• Speed feedforward or force feedforward is input.
• The positioning completed width (Pn522) is too small.
5
5-17
5-18
5 Adjustments
5.3.1 Advanced Autotuning
• Advanced autotuning makes adjustments by referring to the positioning completed width (Pn522). If the SERVOPACK is operated in position control (Pn000.1=1), set the electronic gear ratio (Pn20E/Pn210) and positioning completed width (Pn522) to the actual value during operation. If the SERVOPACK is operated in speed control
(Pn000.1=0), set Mode to 1 to perform advanced autotuning.
• Unless the positioning completed signal (/COIN) is turned ON within approximately 3 seconds after positioning has been completed, "WAITING" will flash. Furthermore, unless the positioning completed signal (/COIN) is turned ON within approximately 10 seconds, "Error" will flash for 2 seconds and tuning will be aborted.
Change only the overshoot detection level (Pn561) to finely adjust the amount of overshooting without changing the positioning completed width (Pn522). Because Pn561 is set by default to 100%, the allowable amount of overshooting is the same amount as that for the positioning completed width.
When Pn561 is set to 0%, the amount of overshooting can be adjusted to prevent overshooting the positioning completed width. If the setting of Pn561 is changed, however, the positioning time may be extended.
Pn561
Overshoot Detection Level
Setting Range
0 to 100
Setting Unit
1%
Speed Position
Factory Setting
100
Force
When Enabled
Immediately
Classification
Setup
5.3 Advanced Autotuning (Fn201)
5.3.2
Advanced Autotuning Procedure
The following procedure is used for advanced autotuning.
Advanced autotuning is performed from the digital operator (option) or SigmaWin+.
The operating procedure from the digital operator is described here.
Refer to the Σ -V Series User’s Manual, Operation of Digital Operator operations of the digital operator.
(No.: SIEP S800000 55) for basic key
CAUTION
• When using the SERVOPACK with Jcalc = OFF (mass is not calculated), be sure to set a suitable value for the mass ratio (Pn103). If the setting greatly differs from the actual mass ratio, normal control of the SER-
VOPACK may not be possible, and vibration may result.
• When using the MP2000 Series with phase control, select the mode = 1 (standard level). If 2 or 3 is selected, phase control of the MP2000 Series may not be possible.
(1) Operating Procedure
Step
1
2
Display after Operation
㧮㧮 ޓ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧜㧦㨀㨡㨚㨑㧸㨢㨘ޓ㧿㨑㨠
㧲㨚㧞㧜㧝㧦㧭㧭㨀
㧲㨚㧞㧜㧞㧦㧾㨑㨒㧭㧭㨀
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
Status Display
㧮㧮 㧭㨐㨢㨍㨚㨏㨑㨐ޓ㧭㨀
ޓ㧶㨏㨍㨘㨏㧩㧻㧺
ޓ㧹 㨛 㨐 㨑㧩㧞ޓ㨀㨥㨜㨑㧩㧞
ޓ㧿㨠㨞㨛㨗㨑㧩㧗㧜㧜㧤㧜㧜㧜㧜㧜
ޓޓޓޓޓޓ㧔㧜㧜㧜㧟㧚㧜㧕㨞㨑㨢
Keys Operation
Press the Key to view the main menu for the utility function.
Use the or Key to move through the list, select Fn201.
Press the Key to display the initial setting screen for F201 (Advanced Autotuning).
3
3-1
3-2
3-3
㧮㧮 㧭㨐㨢㨍㨚㨏㨑㨐ޓ㧭㨀
ޓ㧶㨏㨍㨘㨏㧩㧻㧺
ޓ㧹 㨛 㨐 㨑㧩㧞ޓ㨀㨥㨜㨑㧩㧞
ޓ㧿㨠㨞㨛㨗㨑㧩㧗㧜㧜㧤㧜㧜㧜㧜㧜
ޓޓޓޓޓޓ㧔㧜㧜㧜㧟㧚㧜㧕㨞㨑㨢
Press the , steps 3-1 to 3-4.
, or Key and set the items in
Calculating Mass
Select the mode to be used.
Usually, set Jcalc to ON.
Jcalc = ON: Mass calculated [Factory setting]
Jcalc = OFF: Mass not calculated
Note: If the mass ratio is already known from the machine specifications, set the value in Pn103 and set Jcalc to
OFF.
Mode Selection
Select the mode.
Mode = 1: Makes adjustments considering response characteristics and stability (Standard level).
Mode = 2: Makes adjustments for positioning [Factory setting].
Mode = 3: Makes adjustments for positioning, giving priority to overshooting suppression.
Type Selection
Select the type according to the machine element to be driven. If there is noise or the gain does not increase, better results may be obtained by changing the rigidity type.
Type = 1: Low rigidity
Type = 2: Medium rigidity [Factory setting]
Type = 3: High rigidity
5
5-19
5-20
5 Adjustments
5.3.2 Advanced Autotuning Procedure
Step
3-4
(cont’d)
Display after Operation Keys Operation
STROKE (Travel Distance) Setting
Travel distance setting range:
The travel distance setting range is from -99990000 to +99990000 [reference unit]. Specify the STROKE
(travel distance) in increments of 1000 reference units. The negative (-) direction is for reverse movement, and the positive (+) direction is for forward movement.
Initial value:
About 90 mm
Notes:
• Set the travel distance to at least 5 mm; otherwise, "Error" will be displayed and the travel distance cannot be set.
• To calculate the mass and ensure precise tuning, it is recommended to set the travel distance to about 90 mm.
4
㧮㧮 㧭 㨐㨢㨍㨚㨏㨑㨐 㧭㨀
㧼㨚㧝㧜㧟㧩㧜㧜㧝㧜㧜
㧼㨚㧝㧜㧜㧩㧜㧜㧠㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧞㧜㧜㧜
㧼㨚㧝㧜㧞㧩㧜㧜㧠㧜㧜
5
6
7
8
R U N 㧭 㨐㨢㨍㨚㨏㨑㨐 㧭㨀
㧼㨚㧝㧜㧟㧩㧜㧜㧝㧜㧜
㧼㨚㧝㧜㧜㧩㧜㧜㧠㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧞㧜㧜㧜
㧼㨚㧝 㧠 㧝㧩㧜㧜㧡㧜㧜
㧭㧰㧶 㧭㨐㨢㨍㨚㨏㨑㨐 㧭㨀
㧼㨚㧝㧜㧟㧩㧜㧜㧟㧜㧜
㧼㨚㧝㧜㧜㧩㧜㧜㧠㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧞㧜㧜
㧼㨚㧝㧠㧝㧩㧜㧜㧡㧜㧜
Display example:
After the mass is calculated.
−
A 㧰㧶 㧭 㨐㨢㨍㨚㨏㨑㨐 㧭㨀
㧼㨚㧝㧜㧟㧩㧜㧜㧟㧜㧜
㧼㨚㧝㧜㧜㧩㧜㧝㧜㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧜㧢㧟㧢
㧼㨚㧝㧠㧝㧩㧜㧝㧡㧜㧜
Press the Key. The advanced autotuning execution screen will be displayed.
Press the Key. The servomotor power will be
ON and the display will change from "BB" to
"RUN."
Note: If the mode is set to 1, Pn102 is displayed. If the mode is set to 2 or 3, the Pn102 display will change to the Pn141.
Calculates the mass.
Press the Key if a positive (+) value is set in
STROKE (travel distance), or press the Key if a negative (-) value is set. Calculation of the mass will start. While the mass is being calculated, the set value for Pn103 will flash and “ADJ” will flash instead of
“RUN.” When calculating the mass is completed, the display will stop flashing and the mass is displayed.
The servomotor will remain ON, but the auto run operation will be stopped temporarily.
Notes:
• The wrong key for the set travel direction is pressed, the calculation will not start.
• If the mass is not calculated (Jcalc = OFF), the set value for Pn103 will be displayed.
• If "NO-OP" or "Error" is displayed during operation, press the Key to cancel the function.
Refer to (2) Failure in Operation and take a corrective action to enable operation.
After the servomotor is temporarily stopped, press the
Key to save the calculated mass ratio in the
SERVOPACK. “DONE” will flash for one second, and “ADJ” will be displayed again.
Note: To end operation by calculating only the mass ratio and without adjusting the gain, press the
Key to end operation.
Gain Adjustment
When the or Key is pressed according to the sign (+ or -) of the value set for stroke (travel distance), the calculated value of the mass ratio will be saved in the SERVOPACK and the auto run operation will restart. While the servomotor is running, the filters, and gains will be automatically set. "ADJ" will flash during the auto setting operation.
Note: Precise adjustments cannot be made and
"Error" will be displayed as the status if there is machine resonance when starting adjustments.
If that occurs, make adjustments using oneparameter tuning (Fn203).
5.3 Advanced Autotuning (Fn201)
Step
9
Display after Operation
㧭㧰㧶 㧭 㨐㨢㨍㨚㨏㨑㨐 㧭㨀
㧼㨚㧝㧜㧟㧩㧜㧜㧟㧜㧜
㧼㨚㧝㧜㧜㧩㧜㧝㧜㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧜㧢㧟㧢
㧼㨚㧝㧠㧝㧩㧜㧝㧡㧜㧜
Keys
−
(cont’d)
Operation
When the adjustment has been completed normally, the servomotor power will turn OFF, and "END" will flash for approximately two seconds and then "ADJ" will be displayed on the status display.
10
㧮㧮 㧭㨐㨢㨍㨚㨏㨑㨐 㧭㨀
㧼㨚㧝㧜㧟㧩㧜㧜㧟㧜㧜
㧼㨚㧝㧜㧜㧩㧜㧝㧜㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧜㧢㧟㧢
㧼㨚㧝㧠㧝㧩㧜㧝㧡㧜㧜
Press the Key. The adjusted values will be saved in the SERVOPACK.
"DONE" will flash for approximately two seconds, and "BB" will be displayed.
Note: Press the Key to not save the values. The display will return to that shown in step 1.
11 Turn ON the SERVOPACK power supply again after executing advanced autotuning.
(2) Failure in Operation
When "NO-OP" Flashes on the Display
Probable Cause
The main circuit power supply was OFF.
An alarm or warning occurred.
Overtraveling occurred.
Gain setting 2 was selected by gain switching.
The HWBB function operated.
Corrective Actions
Turn ON the main circuit power supply.
Remove the cause of the alarm or the warning.
Remove the cause of the overtravel.
Disable the automatic gain switching.
Disable the HWBB function.
5
5-21
5-22
5 Adjustments
5.3.2 Advanced Autotuning Procedure
When "Error" Flashes on the Display
Error
The gain adjustment was not successfully completed.
Probable Cause
Machine vibration is occurring or the positioning completed signal (/COIN) is turning
ON and OFF when the servomotor is stopped.
Corrective Actions
• Increase the set value for Pn522.
• Change the mode from 2 to 3.
• If machine vibration occurs, suppress the vibration with the anti-resonance control adjustment function and the vibration suppression function.
An error occurred during the calculation of the mass.
Refer to 5.3.2 (2) When an Error Occurs during Calculation of Mass .
Travel distance setting error
The travel distance is set to approximately 5 mm or less, which is less than the minimum adjustable travel distance.
Increase the travel distance. It is recommended to set the travel distance to 90 mm.
The positioning completed signal (/COIN) did not turn ON within approximately 10 seconds after positioning adjustment was completed.
The mass cannot be calculated when the tuningless function was activated.
The positioning completed width is too narrow or proportional control (P control) is being used.
When the tuning-less function was activated, Jcalc was set to OFF so the mass was not calculated.
• Increase the set value for Pn522.
• Set 0 to V_PPI in the OPTION field.
• Turn OFF the tuning-less function.
• Set Jcalc to ON , so the mass will be calculated.
When an Error Occurs during Calculation of Mass
The following table shows the probable causes of errors that may occur during the calculation of the mass with the Jcalc set to ON, along with corrective actions for the errors.
Error
Display
Err1
Err2
Err3
Err4
Err5
Probable Cause Corrective Actions
The SERVOPACK started calculating the mass, but the calculation was not completed.
The mass fluctuated greatly and did not converge within 10 tries.
Low-frequency vibration was detected.
The force limit was reached.
• Increase the speed loop gain (Pn100).
• Increase the STROKE (travel distance).
Set the calculation value based on the machine specifications in Pn103 and execute the calculation with the
Jcalc set to OFF.
Double the set value of the mass calculating start level
(Pn324).
• When using the force limit, increase the force limit.
• Double the set value of the mass calculating start level (Pn324).
While calculating the mass, the speed control was set to proportional control by setting 1 to
V_PPI in the OPTION field.
Operate the SERVOPACK with PI control while calculating the mass.
5.3 Advanced Autotuning (Fn201)
(3) Related Functions on Advanced Autotuning
This section describes functions related to advanced tuning.
Notch Filter
Usually, set this function to Auto Setting. (The notch filter is factory-set to Auto Setting.)
If this function is set to Auto Setting, vibration will be detected automatically during advanced autotuning and the notch filter will be set.
Set this function to Not Auto Setting only if you do not change the notch filter setting before executing advanced autotuning.
Parameter
Pn460 n.
0 n.
1
[Factory setting] n.
0 n.
1
[Factory setting]
Function
Does not set the 1st notch filter automatically with the utility function.
Sets the 1st notch filter automatically with the utility function.
Does not set the 2nd notch filter automatically with the utility function.
Sets the 2nd notch filter automatically with the utility function.
When Enabled Classification
Immediately Tuning
Anti-Resonance Control Adjustment
This function reduces low vibration frequency, which the notch filter does not detect.
Usually, set this function to Auto Setting. (The anti-resonance control is factory-set to Auto Setting.)
When this function is set to Auto Setting, vibration will be automatically detected during advanced autotuning and anti-resonance control will be automatically adjusted and set.
Parameter
Pn160 n.
0 n.
1
[Factory setting]
Function
Does not use the anti-resonance control automatically with the utility function.
Uses the anti-resonance control automatically with the utility function.
When Enabled Classification
Immediately Tuning
Vibration Suppression
The vibration suppression function suppresses transitional vibration at frequency as low as 1 to 100 Hz that is generated mainly when positioning if the machine stand vibrates.
Usually, set this function to Auto Setting. (The vibration suppression function is factory-set to Auto Setting.)
When this function is set to Auto Setting, vibration will be automatically detected during advanced autotuning and vibration suppression will be automatically adjusted and set.
Set this function to Not Auto Setting only if you do not change the setting for vibration suppression before executing advanced autotuning.
Note: This function uses model following control. Therefore, the function can be executed only if the mode is set to 2 or 3.
• Related Parameter
Pn140
Parameter n.
0 n.
1
[Factory setting]
Function
Does not use the vibration suppression function automatically with the utility function.
Uses the vibration suppression function automatically with the utility function.
When Enabled Classification
Immediately Tuning
5
5-23
5-24
5 Adjustments
5.3.2 Advanced Autotuning Procedure
Friction Compensation
This function compensates for changes in the following conditions.
• Changes in the viscous resistance of the lubricant, such as the grease, on the sliding parts of the machine
• Changes in the friction resistance resulting from variations in the machine assembly
• Changes in the friction resistance due to aging
The conditions for applying friction compensation depend on the mode. The friction compensation setting in
Pn408.3 applies when the Mode is 1. The friction compensation function is always enabled regardless of the friction compensation setting in Pn408.3 when the Mode is 2 or 3.
Mode
Friction
Compensation
Selecting
Pn408 n.0
[Factory setting] n.1
Mode = 1 Mode = 2
Adjusted without the friction compensation function
Adjusted with the friction compensation function
Adjusted with the friction compensation function
Mode = 3
Adjusted with the friction compensation function
Feedforward
If Pn140 is set to the factory setting and the mode setting is changed to 2 or 3, the feedforward gain (Pn109), speed feedforward (VFF) input, and force feedforward (TFF) input will be disabled.
Set Pn140.3 to 1 if model following control is used together with the speed feedforward (VFF) input and force feedforward (TFF) input from the host controller.
Pn140
Parameter n.0
[Factory setting] n.1
Function
Model following control is not used together with the speed/force feedforward input.
Model following control is used together with the speed/force feedforward input.
When Enabled Classification
Immediately Tuning
For the force feedforward (TFF) input and speed feedforward (VFF) input, refer to the
Input
(Manual No.: SIEP S800000 54).
Σ -V Series/DC Power
Σ -V Series/ Σ -V Series for Large-Capacity Models User’s Manual MECHATROLINK-II Commands
Model following control is used to make optimum feedforward settings in the SERVO-
PACK when model following control is used with the feedforward function. Therefore, model following control is not normally used together with either the speed feedforward
(VFF) input or force feedforward (TFF) input from the host controller. However, model following control can be used with the speed feedforward (VFF) input or force feedforward
(TFF) input if required. An improper feedforward input may result in overshooting.
5.3 Advanced Autotuning (Fn201)
5.3.3
Related Parameters
The following table lists parameters related to this function and their possibility of being changed while executing this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes : Parameters can be changed using SigmaWin+ while this function is being executed.
No : Parameters cannot be changed using SigmaWin+ while this function is being executed.
• Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
Parameter
Pn161
Pn163
Pn531
Pn585
Pn534
Pn535
Pn536
Pn141
Pn142
Pn143
Pn144
Pn145
Pn146
Pn147
Pn160
Pn125
Pn401
Pn408
Pn409
Pn40A
Pn40C
Pn40D
Pn140
Pn100
Pn101
Pn102
Pn103
Pn121
Pn123
Pn124
Name
Speed Loop Gain
Speed Loop Integral Time Constant
Position Loop Gain
Mass Ratio
Friction Compensation Gain
Friction Compensation Coefficient
Friction Compensation Frequency Correction
Friction Compensation Gain Correction
Force Reference Filter Time Constant
Force Related Function Switch
1st Notch Filter Frequency
1st Notch Filter Q Value
2nd Notch Filter Frequency
2nd Notch Filter Q Value
Model Following Control Related Switch
Model Following Control Gain
Model Following Control Gain Compensation
Model Following Control Bias (Forward Direction)
Model Following Control Bias (Reverse Direction)
Vibration Suppression 1 Frequency A
Vibration Suppression 1 Frequency B
Model Following Control Speed Feedforward Compensation
Anti-Resonance Control Related Switch
Anti-Resonance Frequency
Anti-Resonance Damping Gain
Program JOG Movement Distance
Program JOG Movement Speed
Program JOG Acceleration/Deceleration Time
Program JOG Waiting Time
Number of Times of Program JOG Movement
No
No
No
No
No
No
Yes
No
No
No
No
No
No
No
Yes
No
No
Mid-execution changes
No
No
No
No
No
Yes
No
No
No
No
No
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Automatic changes
Yes
Yes
Yes
No
Yes
5
5-25
5-26
5 Adjustments
5.4.1 Advanced Autotuning by Reference
5.4
Advanced Autotuning by Reference (Fn202)
Adjustments with advanced autotuning by reference are described below.
• Advanced autotuning by reference starts adjustments based on the set speed loop gain (Pn100). Therefore, precise adjustments cannot be made if there is vibration when starting adjustments. In this case, make adjustments after lowering the speed loop gain (Pn100) until vibration is eliminated.
5.4.1
Advanced Autotuning by Reference
Advanced autotuning by reference is used to automatically achieve optimum tuning of the SERVOPACK in response to the user reference inputs from the host controller.
Advanced autotuning by reference is performed generally to fine-tune the SERVOPACK after advanced autotuning of the SERVOPACK has been performed.
If the mass ratio is correctly set to Pn103, advanced autotuning by reference can be performed without performing advanced autotuning.
Movement
Speed
Reference
Reference
Response
Travel distance
Host Controller
SERVOPACK
Advanced autotuning by reference performs the following adjustments.
• Gains (e.g., position loop gain and speed loop gain)
• Filters (force reference filter and notch filter)
• Friction compensation
• Anti-resonance control
• Vibration suppression
Refer to 5.4.3 Related Parameters for parameters used for adjustments.
CAUTION
• Because advanced autotuning by reference adjusts the SERVOPACK during automatic operation, vibration or overshooting may occur. To ensure safety, perform advanced autotuning by reference in a state where the SERVOPACK can come to an emergency stop at any time.
5.4 Advanced Autotuning by Reference (Fn202)
(1) Preparation
Check the following settings before performing advanced autotuning by reference. The message “NO-OP” indicating that the settings are not appropriate will be displayed, if all of the following conditions are not met.
• The SERVOPACK must be in Servo Ready status (Refer to 4.8.4
).
• There must be no overtravel.
• The servomotor power must be OFF.
• The position control must be selected when the servomotor power is ON.
• The gain selection switch must be in manual switching mode (Pn139.0 = 0).
• Gain setting 1 must be selected.
• The test without a motor function must be disabled (Pn00C.0 = 0).
• All alarms and warnings must be cleared.
• The hardwire baseblock (HWBB) must be disabled.
• The write prohibited setting (Fn010) must be set to Write permitted (P.0000).
• The tuning-less function must be disabled (Pn170.0 = 0).
(2) When Advanced Autotuning by Reference Cannot Be Performed Successfully
Advanced autotuning by reference cannot be performed successfully under the following conditions. If the result of autotuning is not satisfactory, perform one-parameter tuning (Fn203). Refer to 5.5 One-parameter
Tuning (Fn203) for details.
• The travel distance in response to references from the host controller is smaller than the set positioning completed width (Pn522).
• The motor speed in response to references from the host controller is smaller than the set zero speed level
(Pn581).
• The stopping time, i.e., the period while the positioning completed /COIN signal is OFF, is 10 ms or less.
• The rigidity of the machine is low and vibration occurs when positioning is performed.
• The position integration function is used.
• P control operation (proportional control) is performed.
• The mode switch is used.
• The positioning completed width (Pn522) is too small.
• Advanced autotuning by reference starts adjustments based on the positioning completed width (Pn522). Set the electronic gear ratio (Pn20E/Pn210) and positioning completed width (Pn522) to the actual value during operation.
• “WAITING” will flash if the positioning completed signal (/COIN) does not turn ON within approximately 3 seconds after positioning is completed. Furthermore, unless the positioning completed signal (/COIN) is turned ON within approximately 10 seconds, “Error” will flash for 2 seconds and tuning will be aborted.
Change only the overshoot detection level (Pn561) to finely adjust the amount of overshooting without changing the positioning completed width (Pn522). Because Pn561 is set by default to 100%, the allowable amount of overshooting is the same amount as that for the positioning completed width.
When Pn561 is set to 0%, the amount of overshooting can be adjusted without any overshooting in the positioning completed width. If the setting of Pn561 is changed, however, the positioning time may be extended.
Pn561
Overshoot Detection Level
Setting Range
0 to 100
Setting Unit
1%
Speed Position
Factory Setting
100
Force
When Enabled
Immediately
Classification
Setup
5
5-27
5-28
5 Adjustments
5.4.2 Advanced Autotuning by Reference Procedure
5.4.2
Advanced Autotuning by Reference Procedure
The following procedure is used for advanced autotuning by reference.
Advanced autotuning by reference is performed from the digital operator (option) or SigmaWin+.
Here, the operating procedure from the digital operator is described.
Refer to the Σ -V Series User’s Manual, Operation of Digital Operator operations of the digital operator.
(No.: SIEP S800000 55) for basic key
CAUTION
• When using the MP2000 Series with phase control, select the mode = 1 (standard level). If 2 or 3 is selected, phase control of the MP2000 Series may not be possible.
(1) Operating Procedure
Set the correct mass ratio in Pn103 by using the advanced autotuning before performing this procedure.
Step
1
2
Display after Operation
㧮㧮 ޓ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧝㧦㧭㧭㨀
㧲㨚㧞㧜㧞㧦㧾㨑㨒㧭㧭㨀
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
㧲㨚㧞㧜㧠㧦㧭㨂㨕㨎ޓ㧿㨡㨜
Status Display
㧮㧮 㧭㨐㨢㨍㨚㨏㨑㨐 㧭㨀
ޓ㧹 㨛 㨐 㨑㧩㧟ޓ㨀㨥㨜㨑㧩㧞
Keys Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn202.
Key to move through the list and
Press the Key to display the initial setting screen for Fn202 (Advanced Autotuning by Reference).
3
㧮㧮 㧭㨐㨢㨍㨚㨏㨑㨐 㧭㨀
ޓ㧹 㨛 㨐 㨑㧩㧟ޓ㨀㨥㨜㨑㧩㧞
Press the , steps 3-1 and 3-2.
, or Key and set the items in
3-1
3-2
4
Mode Selection
Select the mode.
Mode = 1: Makes adjustments considering response characteristics and stability (Standard level).
Mode = 2: Makes adjustments for positioning [Factory setting].
Mode = 3: Makes adjustments for positioning, giving priority to overshooting suppression.
Type Selection
Select the type according to the machine element to be driven.
If there is noise or the gain does not increase, better results may be obtained by changing the rigidity type.
Type = 1: Low rigidity
Type = 2: Medium rigidity [Factory setting]
Type = 3: High rigidity
㧮㧮 㧭㨐㨢㨍㨚㨏㨑㨐 㧭㨀
㧼㨚㧝㧜㧟㧩㧜㧜㧟㧜㧜
㧼㨚㧝㧜㧜㧩㧜㧜㧠㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧞㧜㧜㧜
㧼㨚㧝㧠㧝㧩㧜㧜㧡㧜㧜
Press the Key. The advanced autotuning by reference execution screen will be displayed.
Note: If the mode is set to 1, Pn102 is displayed. If the mode is set to 2 or 3, the Pn102 display will change to the Pn141.
5
㧾㨁㧺 㧭㨐㨢㨍㨚㨏㨑㨐 㧭㨀
㧼㨚㧝㧜㧟㧩㧜㧜㧟㧜㧜
㧼㨚㧝㧜㧜㧩㧜㧜㧠㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧞㧜㧜㧜
㧼㨚㧝㧠㧝㧩㧜㧜㧡㧜㧜
6 Confirm safety around moving parts.
− Send an SV_ON command from the host controller.
5.4 Advanced Autotuning by Reference (Fn202)
Step
7
Display after Operation
㧭㧰㧶 㧭㨐㨢㨍㨚㨏㨑㨐 㧭㨀
㧼㨚㧝㧜㧟㧩㧜㧜㧟㧜㧜
㧼㨚㧝㧜㧜㧩㧜㧝㧜㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧜㧢㧟㧢
㧼㨚㧝㧠㧝㧩㧜㧝㧡㧜㧜
Keys
(cont’d)
Operation
Input a reference from the host controller and then press the or Key to start the adjustment.
"ADJ" will flash during adjustment on the status display.
Note: Adjustment cannot be performed during "BB" is shown on the status display.
8
㧭㧰㧶 㧭㨐㨢㨍㨚㨏㨑㨐 㧭㨀
㧼㨚㧝㧜㧟㧩㧜㧜㧟㧜㧜
㧼㨚㧝㧜㧜㧩㧜㧝㧜㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧜㧢㧟㧢
㧼㨚㧝㧠㧝㧩㧜㧝㧡㧜㧜
−
When the adjustment has been completed normally,
"END" will flash for approximately two seconds and
"ADJ" will be displayed.
9
㧾㨁㧺 㧭㨐㨢㨍㨚㨏㨑㨐 㧭㨀
㧼㨚㧝㧜㧟㧩㧜㧜㧟㧜㧜
㧼㨚㧝㧜㧜㧩㧜㧝㧜㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧜㧢㧟㧢
㧼㨚㧝㧠㧝㧩㧜㧝㧡㧜㧜
Press the Key to save the settings. "DONE" will flash for approximately two seconds and "RUN" will be displayed.
Note: Not to save the values set in step 6, press the
Key. The display will return to that shown in step 1.
(2) Failure in Operation
When "NO-OP" Flashes on the Display
Probable Cause
The main circuit power supply was OFF.
An alarm or warning occurred.
Overtraveling occurred.
Gain setting 2 was selected by gain switching.
HWBB operated.
When "Error" Flashes on the Display
Corrective Actions
Turn ON the main circuit power supply.
Remove the cause of the alarm or the warning.
Remove the cause of the overtravel.
Disable the automatic gain switching.
Disable the HWBB function.
Error
The gain adjustment was not successfully completed.
Probable Cause
Machine vibration is occurring or the positioning completed signal (/COIN) is turning
ON and OFF when the servomotor is stopped.
Corrective Actions
• Increase the set value for Pn522.
• Change the mode from 2 to 3.
• If machine vibration occurs, suppress the vibration with the anti-resonance control adjustment function and the vibration suppression function.
The positioning completed signal
(/COIN) did not turn ON within approximately 10 seconds after positioning adjustment was completed.
The positioning completed width is too narrow or proportional control (P control) is being used.
• Increase the set value for Pn522.
• Set 0 to V_PPI of OPTION field.
5
5-29
5-30
5 Adjustments
5.4.2 Advanced Autotuning by Reference Procedure
(3) Related Functions on Advanced Autotuning by Reference
This section describes functions related to advanced autotuning by reference.
Notch Filter
Usually, set this function to Auto Setting. (The notch filter is factory-set to Auto Setting.)
If this function is set to Auto Setting, vibration will be detected automatically during advanced autotuning by reference, and the notch filter will be set.
Set this function to Not Auto Setting only if you do not change the notch filter setting before executing advanced autotuning by reference.
Pn460
Parameter n.
n.
1
[Factory setting] n.
0
0
n.
1
[Factory setting]
Function
Does not set the 1st notch filter automatically with the utility function.
Sets the 1st notch filter automatically with the utility function.
Does not set the 2nd notch filter automatically with the utility function.
Sets the 2nd notch filter automatically with the utility function.
When Enabled Classification
Immediately Tuning
Anti-Resonance Control Adjustment
This function reduces low vibration frequency, which the notch filter does not detect.
Usually, set this function to Auto Setting. (The anti-resonance control is factory-set to Auto Setting.)
When this function is set to Auto Setting, vibration will be automatically detected during advanced autotuning by reference and anti-resonance control will be automatically adjusted and set.
Pn160
Parameter n.
0 n.
1
[Factory setting]
Function
Does not use the anti-resonance control automatically with the utility function.
Uses the anti-resonance control automatically with the utility function.
When Enabled Classification
Immediately Tuning
Vibration Suppression
The vibration suppression function suppresses transitional vibration at frequency as low as 1 to 100 Hz that is generated mainly when positioning if the machine stand vibrates.
Usually, set this function to Auto Setting. (The vibration suppression function is factory-set to Auto Setting.)
When this function is set to Auto Setting, vibration will be automatically detected during advanced autotuning by reference and vibration suppression will be automatically adjusted and set.
Set this function to Not Auto Setting only if you do not change the setting for vibration suppression before executing advanced autotuning by reference.
Note: This function uses model following control. Therefore, the function can be executed only if the mode is set to 2 or 3.
• Related Parameters
Pn140
Parameter n.
0 n.
1
[Factory setting]
Function
Does not use the vibration suppression function automatically.
Uses the vibration suppression function automatically.
When Enabled Classification
Immediately Tuning
5.4 Advanced Autotuning by Reference (Fn202)
Friction Compensation
This function compensates for changes in the following conditions.
• Changes in the viscous resistance of the lubricant, such as the grease, on the sliding parts of the machine
• Changes in the friction resistance resulting from variations in the machine assembly
• Changes in the friction resistance due to aging
Conditions to which friction compensation is applicable depend on the mode. The friction compensation setting in Pn408.3 applies when the mode is 1. Mode = 2 and Mode = 3 are adjusted with the friction compensation function regardless of the friction compensation setting in P408.3.
Mode
Friction
Compensation
Selecting
Pn408 n.0
[Factory setting] n.1
Mode = 1 Mode = 2
Adjusted without the friction compensation function
Adjusted with the friction compensation function
Adjusted with the friction compensation function
Mode = 3
Adjusted with the friction compensation function
Feedforward
If Pn140 is set to the factory setting and the mode setting is changed to 2 or 3, the feedforward gain (Pn109), speed feedforward (VFF) input, and force feedforward (TFF) input will be disabled.
Set Pn140.3 to 1 if model following control is used together with the speed feedforward (VFF) input and force feedforward (TFF) input from the host controller.
Pn140
Parameter n.0
[Factory setting] n.1
Function
Model following control is not used together with the speed/force feedforward input.
Model following control is used together with the speed/force feedforward input.
When Enabled Classification
Immediately Tuning
For the force feedforward (TFF) input and speed feedforward (VFF) input, refer to the
Input
Σ -V Series/DC Power
Σ -V Series/ Σ -V Series for Large-Capacity Models User’s Manual MECHATROLINK-II Commands
(Manual No.: SIEP S800000 54).
Model following control is used to make optimum feedforward settings in the SERVO-
PACK when model following control is used with the feedforward function. Therefore, model following control is not normally used together with either the speed feedforward
(VFF) input or force feedforward (TFF) input from the host controller. However, model following control can be used with the speed feedforward (VFF) input or force feedforward
(TFF) input if required. An improper feedforward input may result in overshooting.
5
5-31
5-32
5 Adjustments
5.4.3 Related Parameters
5.4.3
Related Parameters
The following table lists parameters related to this function and their possibility of being changed while executing this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes: Parameters can be changed using SigmaWin+ while this function is being executed.
No: Parameters cannot be changed using SigmaWin+ while this function is being executed.
• Automatic changes after execution of this function
Yes: Parameter set values are automatically set or adjusted after execution of this function.
No: Parameter set values are not automatically set or adjusted after execution of this function.
Parameter
Pn125
Pn401
Pn408
Pn409
Pn40A
Pn40C
Pn40D
Pn140
Pn100
Pn101
Pn102
Pn103
Pn121
Pn123
Pn124
Pn141
Pn142
Pn143
Pn144
Pn145
Pn146
Pn147
Pn160
Pn161
Pn163
Name
Speed Loop Gain
Speed Loop Integral Time Constant
Position Loop Gain
Mass Ratio
Friction Compensation Gain
Friction Compensation Coefficient
Friction Compensation Frequency Correction
Friction Compensation Gain Correction
Force Reference Filter Time Constant
Force Related Function Switch
1st Notch Filter Frequency
1st Notch Filter Q Value
2nd Notch Filter Frequency
2nd Notch Filter Q Value
Model Following Control Related Switch
Model Following Control Gain
Model Following Control Gain Compensation
Model Following Control Bias (Forward Direction)
Model Following Control Bias (Reverse Direction)
Vibration Suppression 1 Frequency A
Vibration Suppression 1 Frequency B
Model Following Control Speed Feedforward Compensation
Anti-Resonance Control Related Switch
Anti-Resonance Frequency
Anti-Resonance Damping Gain
No
No
No
No
No
Yes
No
No
No
Yes
No
No
Mid-execution changes
No
No
No
No
No
Yes
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Automatic changes
Yes
Yes
Yes
No
Yes
5.5 One-parameter Tuning (Fn203)
5.5
One-parameter Tuning (Fn203)
Adjustments with one-parameter tuning are described below.
5.5.1
One-parameter Tuning
One-parameter tuning is used to manually make tuning level adjustments during operation with a position reference or speed reference input from the host controller.
One-parameter tuning enables automatically setting related servo gain settings to balanced conditions by adjusting one or two tuning levels.
One-parameter tuning performs the following adjustments.
• Gains (e.g., position loop gain and speed loop gain)
• Filters (force reference filter and notch filter)
• Friction compensation
• Anti-resonance control
Refer to 5.5.4 Related Parameters for parameters used for adjustments.
Perform one-parameter tuning if satisfactory response characteristics is not obtained with advanced autotuning or advanced autotuning by reference.
To fine-tune each servo gain after one-parameter tuning, refer to 5.8 Additional Adjustment Function .
CAUTION
• Vibration or overshooting may occur during adjustment. To ensure safety, perform one-parameter tuning in a state where the SERVOPACK can come to an emergency stop at any time.
(1) Preparation
Check the following settings before performing one-parameter tuning.
The message “NO-OP” indicating that the settings are not appropriate will be displayed, if all of the following conditions are not met.
• The test without a motor function must be disabled (Pn00C.0 = 0).
• The write prohibited setting (Fn010) must be set to Write permitted (P.0000).
• The tuning-less function must be disabled (Pn170.0 = 0).
• The tuning mode must be set to 0 or 1 when performing speed control.
5
5-33
5-34
5 Adjustments
5.5.2 One-parameter Tuning Procedure
5.5.2
One-parameter Tuning Procedure
The following procedure is used for one-parameter tuning.
There are the following two operation procedures depending on the tuning mode being used.
• When the tuning mode is set to 0 or 1, the model following control will be disabled and one-parameter tuning will be used as the tuning method for applications other than positioning.
• When the tuning mode is set to 2 or 3, the model following control will be enabled and it can be used for tuning for positioning.
One-parameter tuning is performed from the digital operator (option) or SigmaWin+.
Make sure that the mass ratio (Pn103) is set correctly using advance autotuning before beginning operation.
The following section provides the operating procedure from the digital operator.
Refer to the Σ -V Series User’s Manual, Operation of Digital Operator operations of the digital operator.
(No.: SIEP S800000 55) for basic key
CAUTION
• When using the MP2000 Series with phase control, select the tuning mode = 0 or 1. If 2 or 3 is selected, phase control of the MP2000 Series may not be possible.
(1) Digital Operator Operating Procedure
Setting the Tuning Mode 0 or 1
Step Display after Operation
1
㧮㧮ޓ ޓ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧞㧦㧾㨑㨒㧭㧭㨀
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
㧲㨚㧞㧜㧠㧦㧭㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧡㧦㨂㨕㨎ޓ㧿㨡㨜
2
Status Display
㧮 㧮 ̆ 㧻 㨚 㨑 㧼 㨞 㨙 㨀 㨡 㨚̆
㧼 㨚 㧝 㧜 㧟 㧩 㧜 㧜 㧟 㧜 㧜
Keys Operation
Press the Key to view the main menu for the utility function.
Press the or and select Fn203.
Key to move through the list
Press the Key to display the mass ratio set in
Pn103 at present. Move the digit with the or
Key.
Key and change the value with the or
3
㧮 㧮 ̆ 㧻 㨚 㨑 㧼 㨞 㨙 㨀 㨡 㨚̆
㧿 㨑 㨠 㨠 㨕 㨚 㨓
㨀 㨡 㨚 㨕 㨚 㨓 㧹 㨛 㨐 㨑 㧩 㧜
㨀 㨥 㨜 㨑 㧩 㧞
Press the Key to display the initial setting screen for Fn203 (One-parameter Tuning).
4
4-1
4-2
㧮 㧮 ̆ 㧻 㨚 㨑 㧼 㨞 㨙 㨀 㨡 㨚̆
㧿 㨑 㨠 㨠 㨕 㨚 㨓
㨀 㨡 㨚 㨕 㨚 㨓 㧹 㨛 㨐 㨑 㧩 㧜
㨀 㨥 㨜 㨑 㧩 㧞
Press the , steps 4-1 and 4-2.
, or Key and set the items in
Tuning Mode
Select the tuning mode. Select the tuning mode 0 or 1.
Tuning Mode = 0: Makes adjustments giving priority to stability.
Tuning Mode = 1: Makes adjustments giving priority to responsiveness.
Type Selection
Select the type according to the machine element to be driven.
If there is noise or the gain does not increase, better results may be obtained by changing the rigidity type.
Type = 1: Low rigidity
Type = 2: Medium rigidity [Factory setting]
Type = 3: High rigidity
5.5 One-parameter Tuning (Fn203)
Operation
If the servomotor power is OFF, send an SV_ON command from the host controller. The display will change from "BB" to "RUN."
If the servomotor power is ON, go to step 6.
(cont’d)
Step
5
Display after Operation
㧾㨁㧺 ̆ 㧻 㨚 㨑 㧼 㨞 㨙 㨀 㨡 㨚̆
㧿㨑㨠㨠㨕㨚 㨓
㨀 㨡 㨚 㨕 㨚 㨓 㧹 㨛 㨐 㨑 㧩 㧜
㨀 㨥 㨜 㨑 㧩 㧞
6
㧾㨁㧺 ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧼㨚㧝㧜㧜㧩㧜㧜㧠㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧞㧜㧜㧜
㧼㨚㧝㧜㧞㧩㧜㧜㧠㧜㧜
Keys
−
Press the Key to display the set value.
7
8
㧾㨁㧺 ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧸㧱㨂㧱㧸 㧩 㧜㧜㧡㧜
ޓ㧺㧲㧝ޓ㧺㧲㧞
㧭㧾㧱㧿
㧾㨁㧺 ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧸㧱㨂㧱㧸 㧩 㧜㧜㧡㧜
ޓ㧺㧲㧝ޓ㧺㧲㧞
㧭㧾㧱㧿
Press the Key again to display the LEVEL setting screen.
If readjustment is required, select the digit with the
or Key or change the LEVEL with the or Key. Check the response.
If readjustment is not required, go to step 9.
Note: The higher the level, the greater the responsiveness will be. If the value is too large, however, vibration will occur.
• If vibration occurs, press the Key. The SER-
VOPACK will automatically detect the vibration frequencies and make notch filter or an anti-resonance control settings. When the notch filter is set,
"NF1" or "NF2" will be displayed on the bottom row. When the anti-resonance control is set,
"ARES" will be displayed in the lower right corner.
㧾㨁㧺 ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
ޓޓޓ㧸㧱㨂㧱㧸㧩㧜㧜㧣㧜
• If the vibration is great, the vibration frequency will be detected automatically even if the Key is not pressed and a notch filter or an anti-resonance control will be set.
9
㧾㨁㧺 ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧼㨚㧝㧜㧜㧩㧜㧜㧡㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧝㧢㧜
㧼㨚㧝㧜㧞㧩㧜㧜㧡㧜㧜
Press the Key. A confirmation screen will be displayed after LEVEL adjustment.
10
㧾㨁㧺 ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧼㨚㧝㧜㧜㧩㧜㧜㧡㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧝㧢㧜
㧼㨚㧝㧜㧞㧩㧜㧜㧡㧜㧜
• Press the Key to save the adjusted values.
After the data is saved, “DONE” will flash for approximately two seconds and then “RUN” will be displayed.
• To return to the previous value, press the Key.
• Press the Key to readjust the level without saving the values.
11
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧞㧦㧾㨑㨒㧭㧭㨀
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
㧲㨚㧞㧜㧠㧦㧭㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧡㧦㨂㨕㨎ޓ㧿㨡㨜
Press the Key to complete the one-parameter tuning operation. The screen in step 1 will appear again.
Note: The status display will always be RUN when the servomotor power is ON.
5
5-35
5-36
5 Adjustments
5.5.2 One-parameter Tuning Procedure
Setting the Tuning Mode 2 or 3
Step
1
2
Display after Operation
㧮㧮ޓ ޓ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧞㧦㧾㨑㨒㧭㧭㨀
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
㧲㨚㧞㧜㧠㧦㧭㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧡㧦㨂㨕㨎ޓ㧿㨡㨜
Status Display
㧮 㧮 ̆ 㧻 㨚 㨑 㧼 㨞 㨙 㨀 㨡 㨚̆
㧼 㨚 㧝 㧜 㧟 㧩 㧜 㧜 㧟 㧜 㧜
Keys Operation
Press the Key to view the main menu for the utility function.
Press the or and select Fn203.
Key to move through the list
Press the Key to display the mass ratio set in
Pn103 at present. Move the digit with the or
Key.
Key and change the value with the or
3
㧮 㧮 ̆ 㧻 㨚 㨑 㧼 㨞 㨙 㨀 㨡 㨚̆
㧿 㨑 㨠 㨠 㨕 㨚 㨓
㨀 㨡 㨚 㨕 㨚 㨓 㧹 㨛 㨐 㨑 㧩 㧞
㨀 㨥 㨜 㨑 㧩 㧞
Press the Key to display the initial setting screen for Fn203 (One-parameter Tuning).
4
4-1
4-2
5
㧮 㧮 ̆ 㧻 㨚 㨑 㧼 㨞 㨙 㨀 㨡 㨚̆
㧿 㨑 㨠 㨠 㨕 㨚 㨓
㨀 㨡 㨚 㨕 㨚 㨓 㧹 㨛 㨐 㨑 㧩 㧞
㨀 㨥 㨜 㨑 㧩 㧞
Press the , steps 4-1 and 4-2.
, or Key and set the items in
Tuning Mode
Select the tuning mode. Select the tuning mode 2 or 3.
Tuning Mode = 2: Enables model following control and makes adjustments for positioning.
Tuning Mode = 3: Enables model following control, makes adjustments for positioning, and suppresses overshooting.
Type Selection
Select the type according to the machine element to be driven.
If there is noise or the gain does not increase, better results may be obtained by changing the rigidity type.
Type = 1: Low rigidity
Type = 2: Medium rigidity [Factory setting]
Type = 3: High rigidity
㧾㨁㧺 ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
ޓ㧿㨑㨠㨠㨕㨚㨓
㨀㨡㨚㨕㨚㨓ޓ㧹㨛㨐㨑㧩㧞
ޓޓޓޓޓޓޓ㨀㨥㨜㨑㧩㧞
−
If the servomotor power is OFF, send an SV_ON command from the host controller. The display will change from "BB" to "RUN."
If the servomotor power is ON, go to step 6.
6
㧾㨁㧺 ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧼㨚㧝㧜㧜㧩㧜㧜㧠㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧞㧜㧜㧜
㧼㨚㧝㧠㧝㧩㧜㧜㧡㧜㧜
Press the Key to display the set value.
7
㧾㨁㧺ޓ ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧲㧲ޓ㧸㧱㨂㧱㧸㧩㧜㧜㧡㧜㧚㧜
㧲㧮ޓ㧸㧱㨂㧱㧸㧩㧜㧜㧠㧜㧚㧜
Press the Key again to display FF LEVEL and
FB LEVEL setting screens.
Note: The status display will always be RUN when the servomotor power is ON.
5.5 One-parameter Tuning (Fn203)
Step Display after Operation
8
㧾㨁㧺ޓ ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧲㧲ޓ㧸㧱㨂㧱㧸㧩㧜㧜㧡㧜㧚㧜
㧲㧮ޓ㧸㧱㨂㧱㧸㧩㧜㧜㧠㧜㧚㧜
9
㧾㨁㧺 ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧼㨚㧝㧜㧜㧩㧜㧜㧠㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧞㧜㧜㧜
㧼㨚㧝㧠㧝㧩㧜㧜㧡㧜㧜
㧺㧲㧝
10
㧾㨁㧺 ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧼㨚㧝㧜㧜㧩㧜㧜㧠㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧞㧜㧜㧜
㧼㨚㧝㧠㧝㧩㧜㧜㧡㧜㧜
㧺㧲㧝
11
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧞㧦㧾㨑㨒㧭㧭㨀
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
㧲㨚㧞㧜㧠㧦㧭㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧡㧦㨂㨕㨎ޓ㧿㨡㨜
Keys
(cont’d)
Operation
If readjustment is required, select the digit with the
or Key or change the FF LEVEL and FB
LEVEL with the or Key. Check the response.
Refer to 5.5.3 One-parameter Tuning Example for details.
If readjustment is not required, go to step 9.
Note: The higher the FF LEVEL, the positioning time will be shorter and the response will be better.
If the level is too high, however, overshooting or vibration may occur. Overshooting will be reduced if the FB LEVEL is increased.
<NOTE>
• If the FF LEVEL is changed when the servomotor is in operation, it will not be reflected immediately.
The changes will be effective after the servomotor comes to a stop with no reference input and then the servomotor starts operation.
If the FF LEVEL is changed too much during operation, vibration may occur because the responsiveness changes rapidly when the settings become effective.
• The message “FF LEVEL” flashes until the SER-
VOPACK reaches the effective FF LEVEL. If the servomotor does not stop within approximately 10 seconds after changing the setting, a timeout will occur. The setting will be returned to the previous value.
If Vibration Occurs
• If vibration occurs, press the Key. The SER-
VOPACK will automatically detect the vibration frequencies and set the notch filters or anti-resonance control. When the notch filter is set, “NF1” and “NF2” are displayed on the bottom row. When the anti-resonance control is set, “ARES” will be displayed on the bottom row.
㧾㨁㧺ޓ ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧲㧲ޓ㧸㧱㨂㧱㧸㧩㧜㧜㧡㧜㧚㧜
㧲㧮ޓ㧸㧱㨂㧱㧸㧩㧜㧜㧠㧜㧚㧜
ޓ㧺㧲㧝ޓޓ㧺㧲㧞ޓޓ㧭㧾㧱㧿
If Vibration Is Large
• Even if the Key is not pressed, the SERVO-
PACK will automatically detect the vibration frequencies and make notch filter or anti-resonance control settings.
Press the Key to display the confirmation screen after level adjustment.
• Press the Key to save the adjusted values.
After the data is saved, “DONE” will flash for approximately two seconds and then “RUN” will be displayed.
• To return to the previous value, press the Key.
• Press the Key to readjust the level without saving the values.
Press the Key to complete the one-parameter tuning operation. The screen in step 1 will appear again.
5
5-37
5-38
5 Adjustments
5.5.2 One-parameter Tuning Procedure
(2) Related Functions on One-parameter Tuning
This section describes functions related to one-parameter tuning.
Notch Filter
Usually, set this function to Auto Setting. (The notch filter is factory-set to Auto Setting.)
If this function is set to Auto Setting, vibration will be detected automatically during one-parameter tuning and the notch filter will be set.
Set this function to Not Auto Setting only if you do not change the notch filter setting before executing oneparameter tuning.
Pn460
Parameter n.
n.
1
[Factory setting] n.
0
0
n.
1
[Factory setting]
Function
Does not set the 1st notch filter automatically with the utility function.
Sets the 1st notch filter automatically with the utility function.
Does not set the 2nd notch filter automatically with the utility function.
Sets the 2nd notch filter automatically with the utility function.
When Enabled Classification
Immediately
Anti-Resonance Control Adjustment
This function reduces low vibration frequency, which the notch filter does not detect.
Tuning
Usually, set this function to Auto Setting. (The anti-resonance control is factory-set to Auto Setting.)
When this function is set to Auto Setting, vibration will be automatically detected during one-parameter tuning and anti-resonance control will be automatically adjusted and set.
Pn160
Parameter n.
0 n.
1
[Factory setting]
Function
Does not use the anti-resonance control automatically with the utility function.
Uses the anti-resonance control automatically with the utility function.
When Enabled Classification
Immediately Tuning
"ARES" will flash on the digital operator when anti-resonance control adjustment function is set.
㧾㨁㧺 ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧲㧲ޓ㧸㧱㨂㧱㧸ޓ㧩ޓ㧜㧜㧡㧜
㧲㧮ޓ㧸㧱㨂㧱㧸ޓ㧩ޓ㧜㧜㧠㧜ޓ
ޓ
ޓ㧺㧲㧝ޓ㧺㧲㧞ޓޓޓ㧭㧾㧱㧿
5.5 One-parameter Tuning (Fn203)
Friction Compensation
This function compensates for changes in the following conditions.
• Changes in the viscous resistance of the lubricant, such as the grease, on the sliding parts of the machine
• Changes in the friction resistance resulting from variations in the machine assembly
• Changes in the friction resistance due to aging
Conditions to which friction compensation is applicable depend on the tuning mode. The friction compensation setting in F408.3 applies when the mode is 0 or 1. Tuning Mode = 2 and Tuning Mode = 3 are adjusted with the friction compensation function regardless of the friction compensation setting in P408.3.
Mode
Friction
Compensation
Selecting
Pn408 n.0
[Factory setting] n.1
Tuning Mode = 0 Tuning Mode = 1 Tuning Mode = 2 Tuning Mode = 3
Adjusted without the friction compensation function
Adjusted with the friction compensation function
Adjusted without the friction compensation function
Adjusted with the friction compensation function
Adjusted with the friction compensation function
Adjusted with the friction compensation function
Feedforward
If Pn140 is set to the factory setting and the tuning mode setting is changed to 2 or 3, the feedforward gain
(Pn109), speed feedforward (VFF) input, and force feedforward (TFF) input will be disabled.
Set Pn140.3 to 1 if model following control is used together with the speed feedforward (VFF) input and force feedforward (TFF) input from the host controller.
Function When Enabled Classification
Pn140
Parameter n.0
[Factory setting]
Model following control is not used together with the speed/force feedforward input.
Immediately Tuning n.1
Model following control is used together with the speed/force feedforward input.
For the force feedforward (TFF) input and speed feedforward (VFF) input, refer to the
Input
Σ -V Series/DC Power
Σ -V Series/ Σ -V Series for Large-Capacity Models User’s Manual MECHATROLINK-II Commands
(Manual No.: SIEP S800000 54).
Model following control is used to make optimum feedforward settings in the SERVO-
PACK when model following control is used with the feedforward function. Therefore, model following control is not normally used together with either the speed feedforward
(VFF) input or force feedforward (TFF) input from the host controller. However, model following control can be used with the speed feedforward (VFF) input or force feedforward
(TFF) input if required. An improper feedforward input may result in overshooting.
5
5-39
5-40
5 Adjustments
5.5.3 One-parameter Tuning Example
5.5.3
One-parameter Tuning Example
This section describes the procedure to adjust the FF LEVEL and FB LEVEL after step 8 of 5.5.2 (1) Setting the Tuning Mode 2 or 3 and the procedure to save the values after adjustment to the SERVOPACK.
<NOTE>
Positioning time will be shortened if the FF LEVEL is increased. But overshooting and vibrations will occur if it is increased too much.
Overshooting will be reduced if the FB LEVEL is increased.
Step
Panel Display after Operation or Measurement
Results Display Example
Operation
1 –
Perform steps 1 through 7 of 5.5.2 (1) Setting the
Tuning Mode 2 or 3 .
2
3
Position deviation
Positioning time
Positioning completion signal
Reference speed
Measure the positioning time.
If the measurement results and specifications are met, this concludes the tuning. Go to step 8.
If readjustment is required, go to the next step.
㧾㨁㧺ޓ ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧲㧲ޓ㧸㧱㨂㧱㧸㧩㧜㧜㧡㧜㧚㧜
㧲㧮ޓ㧸㧱㨂㧱㧸㧩㧜㧜㧠㧜㧚㧜
First input the reference from the host controller, and then increase the FF LEVEL with the digital operator to shorten the positioning time.
Note 1. If the FF LEVEL is changed when the servomotor is in operation, this value is not effective immediately. The changes will be effective after the servomotor comes to a stop with no reference input and then the servomotor starts operation.
2. If the FF LEVEL is changed too much during operation, vibration may occur because the responsiveness changes rapidly when the settings become effective.
3. If large vibrations occur, the SERVOPACK will automatically detect the vibration frequencies and set the notch filters or anti-resonance control. When a notch filter is set,
“NF1” and “NF2” are displayed on the bottom row of the digital operator. When antiresonance control is set, “ARES” is displayed on the bottom row of the digital operator.
<NOTE>
• Move the digit with the or Key and increase or decrease the value with the or
Key.
• The message “FF LEVEL” flashes until the SER-
VOPACK reaches the effective FF LEVEL. If the servomotor does not stop within approximately 10 seconds after changing the setting, a timeout will occur. The setting will be returned to the previous value.
5.5 One-parameter Tuning (Fn203)
(cont’d)
Step
Panel Display after Operation or Measurement
Results Display Example
Operation
4
5
Overshooting
Measure the positioning time with a measuring instrument.
If the measurement results and specifications are met, this concludes the tuning. Go to step 8.
Go to the next step if overshooting occurs before the specifications are met.
In this measurement results example, the positioning time has decreased over the previous time, but overshooting has occurred.
㧾㨁㧺ޓ ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧲㧲ޓ㧸㧱㨂㧱㧸㧩㧜㧜㧡㧜㧚㧜
㧲㧮ޓ㧸㧱㨂㧱㧸㧩㧜㧜㧡㧜㧚㧜
First input the reference from the host controller, then increase the FB LEVEL with the digital operator to reduce overshooting.
<NOTE>
• Move the digit with the or increase or decrease the value with the
Key.
Key and
or
6
Measure the positioning time with a measuring instrument.
If the measurement results and specifications are met, this concludes the tuning. Go to step 8.
Go back to step 3 if overshooting occurs before the specifications are met.
Go to the next step if vibrations occur before overshooting stops.
7
8
9
㧾㨁㧺ޓ ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧲㧲ޓ㧸㧱㨂㧱㧸㧩㧜㧜㧡㧜㧚㧜
㧲㧮ޓ㧸㧱㨂㧱㧸㧩㧜㧜㧡㧜㧚㧜
ޓ㧺㧲㧝ޓޓ㧺㧲㧞ޓޓ㧭㧾㧱㧿
㧾㨁㧺ޓ ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧼㨚㧝㧜㧜㧩㧜㧜㧡㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧞㧜㧜㧜
㧼㨚㧝㧠㧝㧩㧜㧜㧡㧜㧜
㧺㧲㧝
㧾㨁㧺ޓ ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧼㨚㧝㧜㧜㧩㧜㧜㧡㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧞㧜㧜㧜
㧼㨚㧝㧠㧝㧩㧜㧜㧡㧜㧜
㧺㧲㧝
Press the Key on the digital operator.
The SERVOPACK will automatically detect the vibration frequencies and set the notch filters or an anti-resonance control. When a notch filter is set, “NF1” or
“NF2” is displayed on the bottom row of the digital operator. When anti-resonance control is set, “ARES” is displayed on the bottom row of the digital operator.
<NOTE>
If the vibration is large, a notch filter or anti-resonance control will be automatically set even if the is not pressed.
Key
After making the setting, go back to step 6.
Press the Key. A confirmation screen will be displayed after tuning.
Press the Key. The tuning results data will be saved in the SERVOPACK.
When the data has been saved, “DONE” will flash for two seconds, and then “RUN” will be displayed.
<NOTE>
• Press the Key to cancel saving the data.
• Press the Key to readjust the FF LEVEL and
FB LEVEL without saving the data.
5
5-41
5-42
5 Adjustments
5.5.4 Related Parameters
5.5.4
Related Parameters
The following table lists parameters related to this function and their possibility of being changed while executing this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes: Parameters can be changed using SigmaWin+ while this function is being executed.
No: Parameters cannot be changed using SigmaWin+ while this function is being executed.
• Automatic changes after execution of this function
Yes: Parameter set values are automatically set or adjusted after execution of this function.
No: Parameter set values are not automatically set or adjusted after execution of this function.
Parameter
Pn125
Pn401
Pn408
Pn409
Pn40A
Pn40C
Pn40D
Pn140
Pn100
Pn101
Pn102
Pn103
Pn121
Pn123
Pn124
Pn141
Pn142
Pn143
Pn144
Pn145
Pn146
Pn147
Pn160
Pn161
Pn163
Name
Speed Loop Gain
Speed Loop Integral Time Constant
Position Loop Gain
Mass Ratio
Friction Compensation Gain
Friction Compensation Coefficient
Friction Compensation Frequency Correction
Friction Compensation Gain Correction
Force Reference Filter Time Constant
Force Related Function Switch
1st Notch Filter Frequency
1st Notch Filter Q Value
2nd Notch Filter Frequency
2nd Notch Filter Q Value
Model Following Control Related Switch
Model Following Control Gain
Model Following Control Gain Compensation
Model Following Control Bias (Forward Direction)
Model Following Control Bias (Reverse Direction)
Vibration Suppression 1 Frequency A
Vibration Suppression 1 Frequency B
Model Following Control Speed Feedforward Compensation
Anti-Resonance Control Related Switch
Anti-Resonance Frequency
Anti-Resonance Damping Gain
No
No
No
No
No
Yes
No
No
No
Yes
No
No
Mid-execution changes
No
No
No
No
No
Yes
No
No
No
No
No
No
No
Yes
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Automatic changes
Yes
Yes
Yes
No
Yes
5.6 Anti-Resonance Control Adjustment Function (Fn204)
5.6
Anti-Resonance Control Adjustment Function (Fn204)
This section describes the anti-resonance control adjustment function.
5.6.1
Anti-Resonance Control Adjustment Function
The anti-resonance control adjustment function increases the effectiveness of the vibration suppression after one-parameter tuning. This function is effective in supporting anti-resonance control adjustment if the vibration frequencies are from 100 to 1000 Hz.
This function rarely needs to be used because it is automatically set by the advanced autotuning or advanced autotuning by reference input. Use this function only if fine-tuning is required, or vibration detection is failed and readjustment is required.
Perform one-parameter tuning (Fn203) or use another method to improve the response characteristics after performing this function. If the anti-resonance gain is increased with one-parameter tuning performed, vibration may result again. If that occurs, perform this function again to fine-tune the settings.
CAUTION
• If this function is executed, related parameters will be set automatically. Therefore, there will be a large response change after this function is executed. Enable the function in a state where the machine can come to an emergency stop at any time to ensure the safety operation of the machine.
• Be sure to set a suitable value for the mass ratio (Pn103) using advanced autotuning before executing the anti-resonance control adjustment function. If the setting greatly differs from the actual mass ratio, normal control of the machine may not be possible, and vibration may result.
• This function detects vibration between 100 and 1000 Hz. Vibration will not be detected for frequencies outside of this range, and instead, "F----" will be displayed. If that occurs, use one-parameter tuning with tuning mode 2 selected to automatically set a notch filter or use the vibration suppression function (Fn205).
• Vibration can be reduced more effectively by increasing the anti-resonance damping gain (Pn163). The amplitude of vibration may become larger if the damping gain is excessively high. Increase the damping gain from about 0 to 200% in 10% increments while checking the effect of vibration reduction. If the effect of vibration reduction is still insufficient at a gain of 200%, cancel the setting, and lower the control gain using a different method, such as one-parameter tuning.
(1) Before Performing Anti-Resonance Control Adjustment Function
Check the following settings before performing anti-resonance control adjustment function.
The message “NO-OP” indicating that the settings are not appropriate will be displayed, if all of the following conditions are not met.
• The tuning-less function must be disabled (Pn170.0 = 0).
• The test without a motor function must be disabled (Pn00C.0 = 0).
• The control must not be set to force control.
• The write prohibited setting (Fn010) must be set to Write permitted (P.0000).
5
5-43
5-44
5 Adjustments
5.6.2 Anti-Resonance Control Adjustment Function Operating Procedure
5.6.2
Anti-Resonance Control Adjustment Function Operating Procedure
With this function, an operation reference is sent, and the function is executed while vibration is occurring.
Anti-resonance control adjustment function is performed from the digital operator (option) or SigmaWin+.
The following methods can be used for the anti-resonance control adjustment function.
• Using anti-resonance control for the first time
• With undetermined vibration frequency
• With determined vibration frequency
• For fine-tuning after adjusting the anti-resonance control
The following describes the operating procedure from the digital operator.
Refer to the Σ -V Series User’s Manual, Operation of Digital Operator operations of the digital operator.
(No.: SIEP S800000 55) for basic key
(1) Using Anti-Resonance Control for the First Time
With Undetermined Vibration Frequency
Keys Step
1
2
Display after Operation
㧾㨁㧺ޓ ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
㧲㨚㧞㧜㧠㧦㧭㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧡㧦㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧢㧦㧱㨍㨟㨥ޓ㧲㧲㨀
Status Display
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨀㨡㨚㨕㨚㨓 㧹㨛㨐㨑 㧩 㧜
Operation
Press the Key to view the main menu for the utility function.
Use the select Fn204.
or Key to move through the list,
Press the Key to display the tuning mode selection screen for Fn204 (anti-resonance control adjustment function).
3
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨀㨡㨚㨕㨚㨓 㧹㨛㨐㨑 㧩 㧜
4
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧙㧙㧙㧙 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧜㧜㧜
Press the or
"0."
Key and set the tuning mode
Press the Key while "Tuning Mode = 0" is displayed. The screen shown on the left will appear. The detection of vibration frequencies will start and
"freq" will flash. Return to step 3 if vibration is not detected.
Note: If vibration is not detected even when vibration is occurring, lower the vibration detection sensitivity (Pn311). When this parameter is lowered, the detection sensitivity will be increased.
Vibration may not be detected accurately if too small value is set.
The vibration frequency will be displayed in “freq” if vibration is detected.
5
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧜㧜㧜
−
Example of measured waveform
5.6 Anti-Resonance Control Adjustment Function (Fn204)
Step
6
Display after Operation
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧜㧜㧜
Keys
(cont’d)
Operation
Press the Key. The cursor will move to "damp," and the flashing of "freq" will stop.
Select the digit with the the or
or Key, and press
Key to set the damping gain.
7
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧝㧞㧜
8
9
10
11
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧝㧞㧜
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧞㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧝㧞㧜
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧞㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧝㧞㧜
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
㧲㨚㧞㧜㧠㧦㧭㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧡㧦㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧢㧦㧱㨍㨟㨥ޓ㧲㧲㨀
Example of measured waveform
Note: Increase the damping gain from about 0 to
200% in 10% increments while checking the effect of vibration reduction. If vibration reduction is still insufficient at a gain of 200%, cancel the setting, and lower the control gain by using a different method, such as one-parameter tuning.
If fine tuning of the frequency is necessary, press the
Key. The cursor will move from "damp" to
"freq." If fine-tuning is not necessary, skip step 9 and go to step 10.
Select the digit with the the or
or Key, and press
Key to fine-tune the frequency.
Press the Key to save the settings. "DONE" will flash for approximately two seconds and "RUN" will be displayed.
Press the Key to complete the anti-resonance control adjustment function. The screen in step 1 will appear again.
5
5-45
5-46
5 Adjustments
5.6.2 Anti-Resonance Control Adjustment Function Operating Procedure
With Determined Vibration Frequency
Step
1
Display after Operation
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
㧲㨚㧞㧜㧠㧦㧭㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧡㧦㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧢㧦㧱㨍㨟㨥ޓ㧲㧲㨀
2
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨀㨡㨚㨕㨚㨓 㧹㨛㨐㨑 㧩 㧜
Keys
3
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㨀㨡㨚㨕㨚㨓 㧹㨛㨐㨑 㧩 㧝
Operation
Press the Key to view the main menu for the utility function.
Use the select Fn204.
or Key to move through the list,
Press the Key to display the tuning mode selection screen for Fn204 (anti-resonance control adjustment function).
Press the or
"1."
Key and set the tuning mode
Press the Key while "Tuning Mode = 1" is displayed. The screen shown on the left will appear and
"freq" will flash.
4
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧝㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧜㧜㧜
5
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧝㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧜㧜㧜
6
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧜㧜㧜
Example of measured waveform
Select the digit with the the or
or Key, and press
Key to adjust the frequency.
Press the Key. The cursor will move to "damp."
Step Display after Operation
5.6 Anti-Resonance Control Adjustment Function (Fn204)
Keys
(cont’d)
Operation
Select the digit with the the or
or Key, and press
Key to adjust the damping gain.
7
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧜㧞㧜
8
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧝㧞㧜
9
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧝㧞㧜
Example of measured waveform
Note: Increase the damping gain from about 0 to
200% in 10% increments while checking the effect of vibration reduction. If vibration reduction is still insufficient at a gain of 200%, cancel the setting, and lower the control gain by using a different method, such as one-parameter tuning.
If fine tuning of the frequency is necessary, press the
Key. The cursor will move from "damp" to
"freq." If fine-tuning is not necessary, skip step 9 and go to step 10.
Select the digit with the the or
or Key, and press
Key to fine-tune the frequency.
10
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧝㧞㧜
Press the Key to save the settings. "DONE" will flash for approximately two seconds and "RUN" will be displayed.
11
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
㧲㨚㧞㧜㧠㧦㧭㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧡㧦㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧢㧦㧱㨍㨟㨥ޓ㧲㧲㨀
Press the Key to complete the anti-resonance control adjustment function. The screen in step 1 will appear again.
(2) For Fine-tuning After Adjusting the Anti-Resonance Control
Step
1
Display after Operation
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
㧲㨚㧞㧜㧠㧦㧭㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧡㧦㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧢㧦㧱㨍㨟㨥ޓ㧲㧲㨀
2
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㨀㨡㨚㨕㨚㨓 㧹㨛㨐㨑 㧩 㧝
Keys Operation
Press the Key to view the main menu for the utility function.
Use the or Key to move through the list, select Fn204.
Press the Key to display the "Tuning Mode = 1" as shown on the left.
3
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧝㧞㧜
Press the Key while "Tuning Mode = 1" is displayed. The screen shown on the left will appear and
"damp" will flash.
5
5-47
5-48
5 Adjustments
5.6.3 Related Parameters
Step Display after Operation
4
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧝㧡㧜
5
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧝㧡㧜
Keys
(cont’d)
Operation
Select the digit with the or Key, and press the or Key to set the damping gain.
Note: Increase the damping gain from about 0 to
200% in 10% increments while checking the effect of vibration reduction. If vibration reduction is still insufficient at a gain of 200%, cancel the setting, and lower the control gain by using a different method, such as one-parameter tuning.
If fine tuning of the frequency is necessary, press the
Key. The cursor will move from "damp" to
"freq." If fine-tuning is not necessary, skip step 6 and go to step 7.
Select the digit with the the or
or Key, and press
Key to fine-tune the frequency.
6
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧞㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧝㧡㧜
7
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧞㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧝㧡㧜
Press the Key to save the settings. "DONE" will flash for approximately two seconds and "RUN" will be displayed.
8
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
㧲㨚㧞㧜㧠㧦㧭㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧡㧦㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧢㧦㧱㨍㨟㨥ޓ㧲㧲㨀
Press the Key to complete the anti-resonance control adjustment function. The screen in step 1 will appear again.
5.6.3
Related Parameters
The following table lists parameters related to this function and their possibility of being changed while executing this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes : Parameters can be changed using SigmaWin+ while this function is being executed.
No : Parameters cannot be changed using SigmaWin+ while this function is being executed.
• Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No: Parameter set values are not automatically set or adjusted after execution of this function.
Parameter
Pn160
Pn161
Pn162
Pn163
Pn164
Pn165
Name
Anti-Resonance Control Related Switch
Anti-Resonance Frequency
Anti-Resonance Gain Compensation
Anti-Resonance Damping Gain
Anti-Resonance Filter Time Constant 1 Compensation
Anti-Resonance Filter Time Constant 2 Compensation
Mid-execution changes
Yes
No
Yes
No
Yes
Yes
Automatic changes
Yes
Yes
No
Yes
No
No
5.7 Vibration Suppression Function (Fn205)
5.7
Vibration Suppression Function (Fn205)
The vibration suppression function is described in this section.
5.7.1
Vibration Suppression Function
The vibration suppression function suppresses transitional vibration at frequency as low as 1 to 100 Hz that is generated mainly when positioning if the machine stand vibrates.
This function is set automatically when advanced autotuning or advanced autotuning by reference is executed.
In most cases, this function is not necessary. Use this function only if fine-tuning is required or readjustment is required as a result of a failure to detect vibration.
Perform one-parameter tuning (Fn203) if required to improve the response characteristics after performing this function.
CAUTION
• If this function is executed, related parameters will be set automatically. Therefore, there will be a large response change after this function is enabled or disabled. Enable the function in a state where the machine can come to an emergency stop at any time to ensure the safety operation of the machine.
• Be sure to set a suitable value for the mass ratio (Pn103) using advanced autotuning before executing the vibration suppression function. If the setting greatly differs from the actual mass ratio, normal control of the
SERVOPACK may not be possible, and vibration may result.
• Phase control of the MP2000 Series may not be possible, if the vibration suppression function is performed when using the MP2000 Series with phase control.
• This function detects vibration frequency between 1 to 100 Hz. Vibration will not be detected for frequencies outside of this range, and instead, "F-----" will be displayed.
• Frequency detection will not be performed if no vibration results from position error or the vibration frequencies are outside the range of detectable frequencies. If so, use a device, such as a displacement sensor or vibration sensor, to measure the vibration frequency.
• If vibration frequencies automatically detected are not suppressed, the actual frequency and the detected frequency may differ. Fine-tune the detected frequency if necessary.
(1) Preparation
Check the following settings before performing the vibration suppression function.
The message “NO-OP” indicating that the settings are not appropriate will be displayed, if all of the following conditions are not met.
• The control must be set to position control.
• The tuning-less function must be disabled (Pn170.0 = 0).
• The test without a motor function must be disabled (Pn00C.0 = 0).
• The write prohibited setting (Fn010) must be set to Write permitted (P.0000).
(2) Items Influencing Performance
If continuous vibration occurs when the servomotor is not moving, the vibration suppression function cannot be used to suppress the vibration effectively. If the result is not satisfactory, perform anti-resonance control adjustment function (Fn204) or one-parameter tuning (Fn203).
(3) Detection of Vibration Frequencies
Frequency detection may not be possible if there is not enough vibration to affect the position error or the effect on the position error is minimal. The detection sensitivity can be adjusted by changing the setting for the remained vibration detection width (Pn560), which is set as a percentage of the positioning completed width
(Pn522). Perform detection of vibration frequencies again after adjusting the remained vibration detection width (Pn560).
5
5-49
5-50
5 Adjustments
5.7.2 Vibration Suppression Function Operating Procedure
Remained Vibration Detection Width
Setting Unit
0.1%
Position
Factory Setting
400
When Enabled
Immediately
Classification
Pn560
Setting Range
1 to 3000 Setup
Note: As a guideline, change the setting 10% at a time. The smaller the set value is, the higher the detection sensitivity will be. If the value is too small, however, the vibration may not be detected accurately.
The vibration frequencies that are automatically detected may vary somewhat with each positioning operation.
Perform positioning several times and make adjustments while checking the effect of vibration suppression.
5.7.2
Vibration Suppression Function Operating Procedure
The following procedure is used for vibration suppression function.
Vibration suppression function is performed from the digital operator (option) or SigmaWin+.
The operating procedure from the digital operator is described here.
Refer to the Σ -V Series User’s Manual, Operation of Digital Operator operations of the digital operator.
(No.: SIEP S800000 55) for basic key
Note: If this function is aborted by pressing the MODE/SET Key, the SERVOPACK will continue operating until the servomotor comes to a stop. After the servomotor stops, the set value will return to the previous value.
The operating flow of the vibration suppression function is shown below.
(1) Operating Flow
Execute steps 1 to 3 in the following page.
Vibration detected?
Yes
Execute steps 4 to 8 in the following page.
No
Adjust vibration using measuring device.
Completed
5.7 Vibration Suppression Function (Fn205)
(2) Operating Procedure
Step Display after Operation Keys Operation
1 Input a operation reference and take the following steps while repeating positioning.
2
3
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧠㧦㧭㧙㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧡㧦㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧢㧦㧱㨍㨟㨥ޓ㧲㧲㨀
㧲㨚㧞㧜㧣㧦㨂㧙㧹㨛㨚㨕㨠㨛㨞
㧾㨁㧺 ̆㨂㨕㨎 㧿㨡㨜̆
㧹㨑㨍㨟㨡㨞㨑 㨒㧩㧜㧝㧜㧚㧠㧴㨦
㧿㨑㨠㨠㨕㨚㨓 㨒㧩㧜㧡㧜㧚㧠㧴㨦
Press the Key to view the main menu for the utility function.
Use the or Key to move through the list, select Fn205.
Press the Key. The display shown on the left will appear.
Measure f: Measurement frequency
Setting f: Setting frequency [Factory-set to the set value for Pn145]
If the setting frequency and actual operating frequency are different, "Setting" will flash.
Note: Frequency detection will not be performed if there is no vibration or the vibration frequency is outside the range of detectable frequencies.
The following screen will be displayed if vibration is not detected. If the vibration frequencies are not detected, prepare a means of detecting and measuring the vibration. When the vibration frequencies are measured, go to step 5 and manually set the measured vibration frequency to “Setting f.”
㧾㨁㧺 ̆㨂㨕㨎 㧿㨡㨜̆
㧹㨑㨍㨟㨡㨞㨑㨒 㧩㧙㧙㧙㧙㧙㧴㨦
㧿㨑㨠㨠㨕㨚㨓㨒 㧩㧜㧡㧜㧚㧜㧴㨦
Press the Key. The displayed “Measure f” value will be displayed as the “Setting f” value as well.
4
㧾㨁㧺 ̆㨂㨕㨎 㧿㨡㨜̆
㧹㨑㨍㨟㨡㨞㨑 㨒㧩㧜㧝㧜㧚㧠㧴㨦
㧿㨑㨠㨠㨕㨚㨓 㨒㧩㧜㧝㧜㧚㧠㧴㨦
5
㧾㨁㧺 ̆㨂㨕㨎 㧿㨡㨜̆
㧹㨑㨍㨟㨡㨞㨑 㨒㧩㧜㧝㧜㧚㧠㧴㨦
㧿㨑㨠㨠㨕㨚㨓 㨒㧩㧜㧝㧞㧚㧠㧴㨦
Position
Error
Force reference
Example of measured waveform
If the vibration is not completely suppressed, select the digit with the or Key, and press the
or Key to fine-tune the frequency “setting f.” Skip this step and go to step 7 if the fine-tuning of the frequency is not necessary.
Note: If the setting frequency and actual operating frequency are different, "Setting" will flash.
5
5-51
5-52
5 Adjustments
5.7.2 Vibration Suppression Function Operating Procedure
Step Display after Operation Keys
(cont’d)
Operation
Press the Key. The "Setting f" will change to usual display and the frequency currently displayed will be set for the vibration suppression function
.
6
㧾㨁㧺 ̆㨂㨕㨎 㧿㨡㨜̆
㧹㨑㨍㨟㨡㨞㨑 㨒㧩㧜㧝㧜㧚㧠㧴㨦
㧿㨑㨠㨠㨕㨚㨓 㨒㧩㧜㧝㧞㧚㧠㧴㨦
Position
Error
7
㧾㨁㧺 ޓޓ ̆㨂㨕㨎 㧿㨡㨜̆
㧹㨑㨍㨟㨡㨞㨑㨒 㧩㧙㧙㧙㧙㧙㧴㨦
㧿㨑㨠㨠㨕㨚㨓㨒 㧩㧜㧝㧞㧚㧠㧴㨦
Force reference
Example of measured waveform
Press the Key to save the setting. "DONE" will flash for approximately two seconds and "RUN" will be displayed again.
8
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧠
㧲㨚㧞㧜㧡
㧲㨚㧞㧜㧢
㧲㨚㧞㧜㧣
Press the Key to complete the vibration suppression function. The screen in step 1 will appear again.
No settings related to the vibration suppression function will be changed during operation.
If the servomotor does not stop approximately 10 seconds after the setting changes, a timeout error will result and the previous setting will be automatically enabled again.
The vibration suppression function will be enabled in step 6. The motor response, however, will change when the servomotor comes to a stop with no reference input.
(3) Related Function on Vibration Suppression Function
This section describes functions related to vibration suppression function.
Feedforward
The feedforward gain (Pn109), speed feedforward (VFF) input, and force feedforward (TFF) input will be disabled in the factory setting.
Set Pn140.3 to 1 if model following control is used together with the speed feedforward (VFF) input and force feedforward (TFF) input from the host controller.
Pn140
Parameter n.0
[Factory setting] n.1
Function
Model following control is not used together with the speed/force feedforward input.
Model following control is used together with the speed/force feedforward input.
When Enabled Classification
Immediately Tuning
For the force feedforward (TFF) input and speed feedforward (VFF) input, refer to the
Input
(Manual No.: SIEP S800000 54).
Σ -V Series/DC Power
Σ -V Series/ Σ -V Series for Large-Capacity Models User’s Manual MECHATROLINK-II Commands
5.7 Vibration Suppression Function (Fn205)
Model following control is used to make optimum feedforward settings in the SERVO-
PACK when model following control is used with the feedforward function. Therefore, model following control is not normally used together with either the speed feedforward
(VFF) input or force feedforward (TFF) input from the host controller. However, model following control can be used with the speed feedforward (VFF) input or force feedforward
(TFF) input if required. An improper feedforward input may result in overshooting.
5.7.3
Related Parameters
The following table lists parameters related to this function and their possibility of being changed while executing this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes: Parameters can be changed using SigmaWin+ while this function is being executed.
No: Parameters cannot be changed using SigmaWin+ while this function is being executed.
• Automatic changes after execution of this function
Yes: Parameter set values are automatically set or adjusted after execution of this function.
No: Parameter set values are not automatically set or adjusted after execution of this function.
Parameter
Pn140
Pn141
Pn142
Pn143
Pn144
Pn145
Pn146
Pn147
Pn14A
Pn14B
Name
Model Following Control Related Switch
Model Following Control Gain
Model Following Control Gain Compensation
Model Following Control Bias (Forward Direction)
Model Following Control Bias (Reverse Direction)
Vibration Suppression 1 Frequency A
Vibration Suppression 1 Frequency B
Model Following Control Speed Feedforward Compensation
Vibration Suppression 2 Frequency
Vibration Suppression 2 Compensation
Mid-execution changes
Yes
No
No
No
No
No
No
No
No
No
Automatic changes
Yes
Yes
No
No
No
Yes
Yes
No
No
No
5
5-53
5-54
5 Adjustments
5.8.1 Switching Gain Settings
5.8
Additional Adjustment Function
This section describes the functions that can be used for additional fine tuning after making adjustments with advanced autotuning, advanced autotuning by reference, or one-parameter tuning.
• Switching gain settings
• Friction compensation
• Current control mode selection
• Current gain level setting
• Speed detection method selection
5.8.1
Switching Gain Settings
Two gain switching functions are available, manual switching and automatic switching. The manual switching function uses an external input signal to switch gains, and the automatic switching function switches gains automatically.
By using the gain switching function, the positioning time can be shortened by increasing the gain during positioning and vibration can be suppressed by decreasing the gain while it is stopped.
Pn139
Parameter n.
0
[Factory setting] n.
2
Function
Manual gain switching
Automatic gain switching
Note: n.
1 is reserved. Do not use.
When Enabled Classification
Immediately
For the gain combinations for switching, refer to (1) Gain Combinations for Switching .
Tuning
For the manual gain switching, refer to (2) Manual Gain Switching .
For the automatic gain switching, refer to (3) Automatic Gain Switching .
(1) Gain Combinations for Switching
Setting
Gain
Setting 1
Gain
Setting 2
Speed
Loop Gain
Pn100
Speed Loop
Gain
Pn104
2nd Speed
Loop Gain
Speed Loop
Integral Time
Constant
Pn101
Speed Loop
Integral Time
Constant
Pn105
2nd Speed
Loop Integral
Time Constant
Position
Loop Gain
Pn102
Position
Loop Gain
Pn106
2nd Position Loop
Gain
Force Reference
Filter
Pn401
Force Reference Filter
Time Constant
Pn412
1st Step 2nd
Force Reference Filter
Time Constant
Model Following Control Gain
Pn141
Model Following Control Gain
Pn148
*
*
2nd Model
Following
Control Gain
Model Following Control
Gain Compensation
Pn142
*
Model Following Control
Gain Compensation
Pn149
*
2nd Model Following Control
Gain Compensation
Friction
Compensation Gain
Pn121
Friction
Compensation Gain
Pn122
2nd Gain for
Friction
Compensation
∗ The switching gain settings for the model following control gain and the model following control gain compensation are supported only for manual gain switching.
To enable the gain switching of these parameters, a gain switching input signal must be sent, and the following conditions must be met.
• No command being executed.
• Motor having been completely stopped.
If these conditions are not satisfied, the applicable parameters will not be switched although the other parameters shown in this table will be switched.
5.8 Additional Adjustment Function
(2) Manual Gain Switching
Manual gain switching uses G-SEL of OPTION field to switch between gain setting 1 and gain setting 2.
Type Command Name
Input G-SEL of OPTION field
0
1
Setting Meaning
Switches to gain setting 1.
Switches to gain setting 2.
(3) Automatic Gain Switching
Automatic gain switching is enabled only in position control. The switching conditions are specified using the following settings.
Parameter Setting
Pn139 n.
2
Switching Condition
Condition A satisfied.
Condition A not satisfied.
Setting
Gain setting 1 to gain setting 2
Gain setting 2 to gain setting 1
Select one of the following settings for switching condition A.
Pn139
Parameter
Switching Condition A for Position Control
For Other than
Position Control
(No Switching) n.
0
[Factory setting] n.
n.
n.
n.
n.
1
2
3
4
5
Positioning completed signal (/COIN) ON
Positioning completed signal (/COIN) OFF
Positioning near signal
(/NEAR) ON
Positioning near signal
(/NEAR) OFF
No output for position reference filter and position reference input OFF
Position reference input
ON
Fixed in gain setting 1
Fixed in gain setting 2
Fixed in gain setting 1
Fixed in gain setting 2
Fixed in gain setting 1
Fixed in gain setting 2
Switching Wait
Time
Pn135
Gain Switching
Waiting Time 1
Pn136
Gain Switching
Waiting Time 2
When
Enabled
Immediately
Switching Time
Pn131
Gain Switching
Time 1
Pn132
Gain Switching
Time 2
Classification
Tuning
Automatic Switching Pattern 1 (Pn139 = n.
2)
Condition A satisfied
Switching Waiting Time 1 Pn135
Switching Time 1 Pn131
Gain
Settings 1
Pn100
Pn101
Pn102
Pn121
Pn401
Switching Waiting Time 2 ࠉ Pn136
Switching Time 2 ࠉ Pn132
Condition A not satisfied
Gain
Settings 2
Pn104
Pn105
Pn106
Pn122
Pn412
5
5-55
5-56
5 Adjustments
5.8.1 Switching Gain Settings
Relationship between the Waiting and Switching Times for Gain Switching
In this example, the "positioning completed signal (/COIN) ON" condition is set as condition A for automatic gain switching. The position loop gain is switched from the value in Pn102 (position loop gain) to the value in
Pn106 (2nd position loop gain). When the /COIN signal goes ON, the switching operation begins after the waiting time set in Pn135. The switching operation changes the position loop gain linearly from Pn102 to
Pn106 within the switching time set in Pn131.
Pn102
Position Loop Gain
Switching
Waiting Time
Pn135
Switching Time
Pn131
Pn106
2nd Position
Loop Gain
/COIN
Switching condition A satisfied
Note: Automatic gain switching is available in the PI and I-P controls (Pn10B).
(4) Related Parameters
Pn100
Pn101
Pn102
Pn401
Pn141
Pn142
Speed Loop Gain
Setting Range
10 to 20000
Setting Unit
0.1 Hz
Speed Loop Integral Time Constant
Setting Range
15 to 51200
Position Loop Gain
Setting Unit
0.01 ms
Setting Range
10 to 20000
Setting Unit
0.1/s
Force Reference Filter Time Constant
Setting Range
0 to 65535
Model Following Control Gain
Setting Unit
0.01 ms
Setting Range
10 to 20000
Setting Unit
0.1/s
Model Following Control Gain Compensation
Setting Range
500 to 2000
Friction Compensation Gain
Setting Unit
0.1%
Pn121
Pn104
Setting Range
10 to 1000
2nd Speed Loop Gain
Setting Range
10 to 20000
Setting Unit
1%
Setting Unit
0.1 Hz
500
Speed
Factory Setting
400
Speed
Factory Setting
2000
Factory Setting
400
Speed Position
Factory Setting
100
Factory Setting
Factory Setting
1000
Speed
Factory Setting
100
Speed
Factory Setting
400
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
Force
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
5.8 Additional Adjustment Function
2nd Speed Loop Integral Time Constant
Factory Setting
2000
Speed
Pn105
Setting Range
15 to 51200
2nd Position Loop Gain
Pn106
Pn412
Pn148
Pn149
Pn122
Setting Unit
0.01 ms
Setting Range
10 to 20000
Setting Unit
0.1/s
1st Step 2nd Force Reference Filter Time
Constant
Setting Range Setting Unit
0 to 65535 0.01 ms
Factory Setting
400
Speed Position
Factory Setting
100
2nd Model Following Control Gain
Setting Range
10 to 20000
Setting Unit
0.1/s
2nd Model Following Control Gain Compensation
Factory Setting
500
Setting Range
500 to 2000
Setting Unit
0.1%
2nd Gain for Friction Compensation
Factory Setting
1000
Setting Range
10 to 1000
Setting Unit
1%
Speed
Factory Setting
100
Position
When Enabled
Immediately
Position
When Enabled
Immediately
(cont’d)
Classification
Tuning
Classification
Tuning
Force
Classification
When Enabled
Immediately Tuning
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
(5) Parameters for Automatic Gain Switching
Gain Switching Time 1
Pn131
Pn132
Pn135
Pn136
Setting Range
0 to 65535
Gain Switching Time 2
Setting Unit
1 ms
Setting Range
0 to 65535
Setting Unit
Gain Switching Waiting Time 1
1 ms
Setting Range
0 to 65535
Setting Unit
Gain Switching Waiting Time 2
1 ms
Setting Range
0 to 65535
Setting Unit
1 ms
(6) Related Monitor
Factory Setting
0
Factory Setting
0
Factory Setting
0
Factory Setting
0
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
Monitor No. (Un)
Un014
Name
Effective gain monitor
Value
1
2
For gain setting 1
Remarks
For gain setting 2
Note: When using the tuning-less function, gain setting 1 is enabled.
Parameter No.
Analog Monitor
Name Output Value
Pn006
Pn007 n.
0B
Effective gain monitor
1 V
2 V
Remarks
Gain setting 1 is enabled.
Gain setting 2 is enabled.
5
5-57
5-58
5 Adjustments
5.8.2 Manual Adjustment of Friction Compensation
5.8.2
Manual Adjustment of Friction Compensation
Friction compensation rectifies the viscous friction change and regular load change.
The friction compensation function can be automatically adjusted with advanced autotuning (Fn201), advanced autotuning by reference input (Fn202), or one-parameter tuning (Fn203). This section describes the steps to follow if manual adjustment is required.
(1) Required Parameter Settings
The following parameter settings are required to use friction compensation.
Pn408
Parameter n.0
[Factory setting] n.1
Function
Does not use friction compensation.
Uses friction compensation.
When Enabled Classification
Immediately Setup
Pn121
Pn123
Pn124
Pn125
Friction Compensation Gain
Setting Range
10 to 1000
Setting Unit
1%
Friction Compensation Coefficient
Setting Range
0 to 100
Setting Unit
1%
Friction Compensation Frequency Correction
Setting Range
-10000 to 10000
Setting Unit
0.1 Hz
Friction Compensation Gain Correction
Setting Range
1 to 1000
Setting Unit
1%
Speed
Factory Setting
100
Speed
Factory Setting
0
Speed
Factory Setting
0
Speed
Factory Setting
100
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
5.8 Additional Adjustment Function
(2) Operating Procedure for Friction Compensation
The following procedure is used for friction compensation.
CAUTION
• Before using friction compensation, set the mass ratio (Pn103) as accurately as possible. If the wrong mass ratio is set, vibration may result.
Step
1
Operation
Set the following parameters for friction compensation to the factory setting as follows.
Friction compensation gain (Pn121): 100
Friction compensation coefficient (Pn123): 0
Friction compensation frequency correction (Pn124): 0
Friction compensation gain correction (Pn125): 100
Note: Always use the factory-set values for friction compensation frequency correction (Pn124) and friction compensation gain correction (Pn125).
To check the effect of friction compensation, gradually increase the friction compensation coefficient (Pn123).
Note: Usually, set the friction compensation coefficient value to 95% or less. If the effect is insufficient, increase the friction compensation gain (Pn121) by 10% increments until it stops vibrating.
2
Effect of Parameters for Adjustment
Pn121: Friction Compensation Gain
This parameter sets the responsiveness for external disturbance. The higher the set value is, the better the responsiveness will be. If the equipment has a resonance frequency, however, vibration may result if the set value is excessively high.
Pn123: Friction Compensation Coefficient
This parameter sets the effect of friction compensation. The higher the set value is, the more effective friction compensation will be. If the set value is excessively high, however, the vibration will occur easily. Usually, set the value to 95% or less.
Effect of Adjustment
The following graph shows the responsiveness with and without proper adjustment.
Insufficient responsiveness because of friction
Small friction
Responsiveness is
ᦶ᧿㸪ᦶ᧿ᑠ compensation.
3
Large friction
Without friction compensation With friction compensation
5
5-59
5-60
5 Adjustments
5.8.3 Current Control Mode Selection Function
5.8.3
Current Control Mode Selection Function
This function reduces high-frequency noises while the servomotor is being stopped. This function is enabled by default and set to be effective under different application conditions. Set Pn009.1 = 1 to use this function.
This function can be used with the following SERVOPACKs.
Input Voltage
200 V
400 V
SERVOPACK Model SGDV-
120A, 180A, 200A, 330A, 550A
3R5D, 5R4D, 8R4D, 120D, 170D, 260D
Pn009
Parameter n. 0 n. 1
[Factory setting]
Meaning
Selects the current control mode 1.
Selects the current control mode 2 (low noise).
When Enabled
After restart
Classification
Tuning
• If current control mode 2 is selected, the load ratio may increase while the servomotor is being stopped.
5.8.4
Current Gain Level Setting
This function reduces noises by adjusting the parameter value for current control inside the SERVOPACK according to the speed loop gain (Pn100). The noise level can be reduced by reducing the current gain level
(Pn13D) from its factory setting of 2000% (disabled). If the set value of Pn13D is decreased, the level of noise will be lowered, but the response characteristics of the SERVOPACK will also be degraded. Adjust the current gain level within the allowable range at which SERVOPACK response characteristics can be secured.
Pn13D
Current Gain Level
Setting Range
100 to 2000
Speed Position
Factory Setting
2000
When Enabled
Immediately
Classification
Setting Unit
1% Tuning
• If this parameter is changed, the response characteristics of the speed loop will also change, and the SERVOPACK may require readjustment.
5.8.5
Speed Detection Method Selection
The speed detection method selection can be used to smooth the speed of the servomotor during operation. To smooth the speed of the servomotor during operation, set Pn009 to n.
1 to select speed detection 2.
When the scale pitch of the linear scale is large, the noise level of the running servomotor can be reduced.
Pn009
Parameter Meaning n. 0
[Factory setting] Selects speed detection 1. n. 1 Selects speed detection 2.
When Enabled
After restart
Classification
Tuning
• If the speed detection method is changed, the response characteristics of the speed loop will also change, and the SERVOPACK may require readjustment.
5.9 Compatible Adjustment Function
5.9
Compatible Adjustment Function
The Σ -V series SERVOPACKs have adjustment functions as explained in sections 5.1
to 5.8
to make machine adjustments.
This section explains compatible functions provided by earlier models, such as the Σ -III Series SERVOPACK.
5.9.1
Feedforward Reference
This function applies feedforward compensation to position control and shortens positioning time.
Position reference
+
Differential
Pn109
Feedforward Gain
Pn10A
Feedforward Filter
Time Constant
+ +
Position loop gain (Kp)
-
Feedback pulse
Pn109
Feedforward Gain
Setting Range
0 to 100
Setting Unit
1%
Factory Setting
0
Position
When Enabled
Immediately
Classification
Tuning
Feedforward Filter Time Constant
Setting Unit
0.01 ms
Factory Setting
0
Position
When Enabled
Immediately
Classification
Pn10A
Setting Range
0 to 6400 Tuning
Note: Too high value may cause the machine to vibrate. For ordinary machines, set 80% or less in this parameter.
5
5-61
5-62
5 Adjustments
5.9.2 Mode Switch (P/PI Switching)
5.9.2
Mode Switch (P/PI Switching)
The mode switch automatically switches between proportional and PI control. Set the switching condition with Pn10B.0 and set the level of detection points with Pn10C, Pn181, Pn182, and Pn10F.
Overshooting caused by acceleration and deceleration can be suppressed and the settling time can be reduced by setting the switching condition and detection points.
Without Mode Switch With Mode Switch
Motor speed
Overshoot
Actual servomotor operation
Motor speed
Reference
Overshoot
Settling time
Time
Settling time
Time
(1) Related Parameters
Select the switching condition of the mode switch with Pn10B.0.
Parameter Mode Switch Selection
Pn10B n.
0
[Factory setting] n.
n.
n.
n.
1
2
3
4
Uses an internal force reference level for the switching conditions.
Uses a speed reference level for the switching conditions.
Uses an acceleration level for the switching conditions.
Uses a position error level for the switching conditions.
Does not use mode switch function.
Parameter
Containing
Detection
Point Setting
When
Enabled
Classification
Pn10C
Pn181
Pn182
Pn10F
−
Immediately
Setup
Parameters to Set the Level of Detection Points
Pn10C
Mode Switch (Force Reference)
Setting Range
0 to 800
Setting Unit
1%
Pn181
Mode Switch (Speed Reference)
Setting Range
0 to 10000
Setting Unit
1 mm/s
Pn182
Mode Switch (Acceleration)
Setting Range
0 to 30000
Setting Unit
1 mm/s
2
Pn10F
Mode Switch (Position Error)
Setting Range
0 to 10000
Setting Unit
1 reference unit
Speed
Factory Setting
200
Speed
Factory Setting
0
Speed
Factory Setting
0
Factory Setting
0
Position
When Enabled
Immediately
Position
When Enabled
Immediately
Position
When Enabled
Immediately
Position
When Enabled
Immediately
Classification
Tuning
Classification
Tuning
Classification
Tuning
Classification
Tuning
5.9 Compatible Adjustment Function
(2) Operating Examples for Different Switching Conditions
Using the Internal Force Reference [Factory Setting]
With this setting, the speed loop is switched to P control when the value of internal force reference input exceeds the force set in Pn10C. The factory setting for the force reference detection point is 200% of the rated force.
Speed
Speed reference
Motor speed
Internal force reference
Time
+Pn10C
Force
Reference
0
- Pn10C
PI P PI Control P PI Control
Using the Speed Reference
With this setting, the speed loop is switched to P control when the value of speed reference input exceeds the speed set in Pn181.
Speed
Speed reference
Motor speed
Pn181
PI P Control
Time
PI Control
Using Acceleration
With this setting, the speed loop is switched to P control when the speed reference exceeds the acceleration set in Pn182.
Speed
Speed reference
Motor speed
Time
Motor acceleration
+Pn182
Acceleration 0
- Pn182
PI P PI Control P PI Control
Using the Position Error
With this setting, the speed loop is switched to P control when the position error exceeds the value set in
Pn10F.
This setting is effective with position control only.
Speed reference
Speed
Motor speed
Time
Position error
Pn10F
PI P Control PI Control
5
5-63
5-64
5 Adjustments
5.9.3 Force Reference Filter
5.9.3
Force Reference Filter
As shown in the following diagram, the force reference filter contains first order lag filter and notch filters arrayed in series, and each filter operates independently. The notch filters can be enabled and disabled with the
Pn408.
Force Related
Function Switch
Pn408
Force reference before filtering
Force
Reference
Filter
(Pn401)
*
2nd Force
Reference
Filter
(Pn40F,
Pn410)
1st Notch
Filter
(Pn409,
Pn40A, and Pn40B)
2nd
Notch
Filter
(Pn40C,
Pn40D, and
Pn40E)
Force reference after filtering
First order lag filter Second order lag filter
Notch filter
* The 2nd force reference filter is enabled when Pn40F is set to a value less than
5000 and disabled when Pn40F is set to 5000 (factory setting).
Notch filter
(1) Force Reference Filter
If you suspect that machine vibration is being caused by the servo drive, try adjusting the filter time constants with Pn401. This may stop the vibration. The lower the value, the better the response will be, but there may be a limit that depends on the machine conditions.
Pn401
Force Reference Filter Time Constant
Setting Range
0 to 65535
Setting Unit
0.01 ms
Speed Position
Factory Setting
100
Force Reference Filter Setting Guide
Speed Loop Gain and Force Reference Filter Time Constant
Force
When Enabled
Immediately
Adjusted value for stable control: Pn401 [ms] ≤ 1000/ (2 π × Pn100 [Hz] × 4)
Critical gains: Pn401 [ms] < 1000/ (2 π × Pn100 [Hz] × 1)
Pn40F
Pn410
2nd Step 2nd Force Reference Filter
Frequency
Setting Range
100 to 5000
Setting Unit
1 Hz
2nd Step 2nd Force Reference Filter Q
Value
Setting Range
50 to 100
Setting Unit
0.01
∗ The filter is disabled if 5000 is set.
Speed Position
Factory Setting
5000*
Force
When Enabled
Immediately
Speed Position
Factory Setting
50
Force
When Enabled
Immediately
Classification
Tuning
Classification
Tuning
Classification
Tuning
5.9 Compatible Adjustment Function
(2) Notch Filter
The notch filter can eliminate specific frequency elements generated by the vibration of sources such as resonance of the machine. The notch filter puts a notch in the gain curve at the specific vibration frequency. The frequency characteristics near the notch can be reduced or removed with this filter. A higher Q value produces a sharper notch and phase delay.
Q value = 1.0
Notch Filter
Q value = 0.7
Notch Filter
100
0
Gain
(db)
-100
-200
-300
10
2
10
3
Frequency (Hz)
Notch Filter
10
4
0
-100
Phase
(deg)
-200
-300
-400
10
2
10
3
Frequency (Hz)
10
4
The notch filter can be enabled or disabled with Pn408.
100
0
Gain
(db)
-100
-200
-300
10
2
0
-100
Phase
(deg)
-200
-300
-400
10
2
Pn408
Parameter n.
0
[Factory setting] n.
1 n.
0
[Factory setting] n.
1
Meaning
Disables 1st notch filter.
Enables 1st notch filter.
Disables 2nd notch filter.
Enables 2nd notch filter.
Set the machine's vibration frequency as a parameter of the notch filter.
10
3
Frequency (Hz)
Notch Filter
10
3
Frequency (Hz)
10
4
10
4
When Enabled Classification
Immediately Setup
Pn409
Pn40A
Pn40B
Pn40C
1st Notch Filter Frequency
Setting Range
50 to 5000
1st Notch Filter Q Value
Setting Unit
1 Hz
Setting Range
50 to 1000
1st Notch Filter Depth
Setting Unit
0.01
Setting Range
0 to 1000
Setting Unit
2nd Notch Filter Frequency
0.001
Setting Range
50 to 5000
Setting Unit
1 Hz
Speed Position
Factory Setting
5000
Force
When Enabled
Immediately
Speed Position Force
Factory Setting
70
When Enabled
Immediately
Speed Position Force
Factory Setting
0
When Enabled
Immediately
Speed Position Force
Factory Setting
5000
When Enabled
Immediately
Classification
Tuning
Classification
Tuning
Classification
Tuning
Classification
Tuning
5
5-65
5-66
5 Adjustments
5.9.4 Position Integral
Pn40D
Pn40E
2nd Notch Filter Q Value
Setting Range
50 to 1000
2nd Notch Filter Depth
Setting Range
0 to 1000
Setting Unit
0.01
Setting Unit
0.001
Speed Position Force
Factory Setting
70
When Enabled
Immediately
Speed Position Force
Factory Setting
0
When Enabled
Immediately
(cont’d)
Classification
Tuning
Classification
Tuning
• Sufficient precautions must be taken when setting the notch filter frequencies. Do not set the notch filter frequencies (Pn409 or Pn40C) that is close to the speed loop’s response frequency. Set the frequencies at least four times higher than the speed loop’s response frequency. Setting the notch filter frequency too close to the response frequency may cause vibration and damage the machine.
• Change the notch filter frequencies (Pn409 or Pn40C) only when the servomotor is stopped. Vibration may occur if the notch filter frequency is changed when the servomotor is moving.
5.9.4
Position Integral
The position integral is the integral function of the position loop. It is used for the electronic cams and electronic shafts when using the SERVOPACK with YASKAWA MP900/2000 Machine Controllers.
Pn11F
Position Integral Time Constant
Setting Range
0 to 50000
Setting Unit
0.1 ms
Factory Setting
0
Position
When Enabled
Immediately
Classification
Tuning
6
Utility Functions (Fn
)
6.1 List of Utility Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
6.2 Alarm History Display (Fn000) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
6.3 JOG Operation (Fn002) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
6.4 Origin Search (Fn003) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
6.5 Program JOG Operation (Fn004) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8
6.6 Initializing Parameter Settings (Fn005) . . . . . . . . . . . . . . . . . . . . . . . . . . 6-12
6.7 Clearing Alarm History (Fn006) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-13
6.8 Offset Adjustment of Analog Monitor Output (Fn00C) . . . . . . . . . . . . . . 6-14
6.9 Gain Adjustment of Analog Monitor Output (Fn00D) . . . . . . . . . . . . . . . 6-16
6.10 Automatic Offset-Signal Adjustment of the Motor Current
Detection Signal (Fn00E) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-18
6.11 Manual Offset-Signal Adjustment of the Motor Current
Detection Signal (Fn00F) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-19
6.12 Write Prohibited Setting (Fn010) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-21
6.13 Servomotor Model Display (Fn011) . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-23
6.14 Software Version Display (Fn012) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-24
6.15 Resetting Configuration Errors in Option Modules (Fn014) . . . . . . . . . 6-25
6.16 Vibration Detection Level Initialization (Fn01B) . . . . . . . . . . . . . . . . . . 6-26
6.17 Display of SERVOPACK and Servomotor ID (Fn01E) . . . . . . . . . . . . . 6-28
6.18 Origin Setting (Fn020) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-30
6.19 Software Reset (Fn030) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-31
6.20 Polarity Detection (Fn080) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-32
6.21 EasyFFT (Fn206) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-33
6.22 Online Vibration Monitor (Fn207) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-36
6
6-1
6-2
6 Utility Functions (Fn )
6.1
List of Utility Functions
Utility functions are used to execute the functions related to servomotor operation and adjustment.
Each utility function has a number starting with Fn.
The following table lists the utility functions and reference section.
Function
No.
Fn011
Fn012
Fn014
Fn01B
Fn01E
Fn020
Fn030
Fn080
Fn200
Fn201
Fn202
Fn203
Fn204
Fn205
Fn206
Fn207
Fn000
Fn002
Fn003
Fn004
Fn005
Fn006
Fn00C
Fn00D
Fn00E
Fn00F
Fn010
Function
Alarm history display
JOG operation
Origin search
Program JOG operation
Initializing parameter settings
Clearing alarm history
Offset adjustment of analog monitor output
Gain adjustment of analog monitor output
Automatic offset-signal adjustment of the motor current detection signal
Manual offset-signal adjustment of the motor current detection signal
Write prohibited setting
Servomotor model display
Software version display
Resetting configuration error in option modules
Vibration detection level initialization
Display of SERVOPACK and servomotor ID
Origin setting
Software reset
Polarity Detection
Tuning-less levels setting
Advanced autotuning
Advanced autotuning by reference
One-parameter tuning
Anti-resonance control adjustment function
Vibration suppression function
EasyFFT
Online vibration monitor
Reference
Section
5.2.2
5.3.2
5.4.2
5.5.2
5.6.2
5.7.2
6.21
6.22
6.15
6.16
6.17
6.18
6.19
6.20
6.7
6.8
6.9
6.10
6.11
6.12
6.13
6.14
6.2
6.3
6.4
6.5
6.6
Note: Execute the utility function with either a digital operator or SigmaWin+. If they are used together, "no_oP" or "NO-
OP" will be displayed when the utility function is executed.
6.2 Alarm History Display (Fn000)
6.2
Alarm History Display (Fn000)
This function displays the last ten alarms that have occurred in the SERVOPACK.
The latest ten alarm numbers and time stamps* can be checked.
∗ Time Stamps
A function that measures the ON times of the control power supply and main circuit power supply in 100-ms units and displays the total operating time when an alarm occurs. The time stamp operates around the clock for approximately 13 years.
<Example of Time Stamps>
If 36000 is displayed,
3600000 [ms] = 3600 [s] = 60 [min] = 1 [h]
Therefore, the total number of operating hours is 1 hour.
(1) Preparation
There are no tasks that must be performed before displaying the alarm history.
(2) Operating Procedure
Use the following procedure.
Step
1
Display after Operation
B B − F U N C T I O N −
F n 2 0 7 : V − M o n i t o r
F n 0 0 0 : A l m H i s t o r y
F n 0 0 2 : J O G
F n 0 0 3 : Z
−
S e a r c h
Keys Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn000.
Key to move through the list and
2
A . D 0 0 − A L A R M −
0 : D 0 0 0 0 0 0 1 2 0 7 1 9 6
1 : 7 2 0 0 0 0 0 0 0 3 2 6 5 1
2 : 5 1 1 0 0 0 0 0 0 0 9 0 4 3
3 : − − −
Press the Key. The display changes to the Fn000 execution display.
3
A . D 0 0 − A L A R M −
1 : 7 2 0 0 0 0 0 0 0 3 2 6 5 1
2 : 5 1 1 0 0 0 0 0 0 0 9 0 4 3
3 : − − −
4 : − − −
Time stamp
Alarm no.
Alarm history no.
0: Latest
9: Oldest
Press the or Key to scroll through the alarm history. The alarm history can be viewed.
4
B B − F U N C T I O N −
F n 2 0 7 : V − M o n i t o r
F n 0 0 0 : A l m H i s t o r y
F n 0 0 2 : J O G
F n 0 0 3 : Z − S e a r c h
Press the Key.
The display returns to the main menu of the utility function.
<NOTE>
• If the same alarm occurs after more than one hour, the alarm will be saved. If it occurs in less than one hour, it will not be saved.
• If no alarm has occurred, “ :---” will be displayed on the digital operator.
• Delete the alarm history using the parameter Fn006. The alarm history is not cleared on alarm reset or when the
SERVOPACK main circuit power is turned OFF.
6
6-3
6-4
6 Utility Functions (Fn )
6.3
JOG Operation (Fn002)
JOG operation is used to check the operation of the servomotor under speed control without connecting the
SERVOPACK to the host controller.
CAUTION
• While the SERVOPACK is in JOG operation, the overtravel function will be disabled. Consider the operating range of the machine when performing JOG operation for the SERVOPACK.
(1) Preparation
The following conditions must be met to perform a jog operation.
• The write prohibited setting (Fn010) must be set to Write permitted (P.0000).
• The main circuit power supply must be ON.
• All alarms must be cleared.
• The hardwire baseblock (HWBB) must be disabled.
• The servomotor power must be OFF.
• The JOG speed must be set considering the operating range of the machine.
Set the jog speed in Pn383.
Pn383
Jog Speed
Setting Range
0 to 10000
Speed
Factory Setting
Position Force
When Enabled
50 Immediately
Classification
Setting Unit
1 mm/s Setup
(2) Operating Procedure
Use the following procedure. The following example is for when the moving direction of the servomotor is set as Pn000.0 = 0 (Sets the linear scale counting up direction as the forward direction).
The tuning-less function is by default set enabled. When the tuningless function is enabled, the gain may be so increased to cause vibration during no-load operation. If vibration occurs, disable the tuningless function by setting the parameter Pn170.0 to 0.
Step
1
Display after Operation
B B − F U N C T I O N −
F n 0 0 0 : A l m H i s t o r y
F n 0 0 2 : J O G
F n 0 0 3 : Z − S e a r c h
F n 0 0 4 : P r o g r a m J O G
2
3
4
B B
−
J O G
−
P n 3 8 3 = 0 0 5 0 0
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0
B B − J O G −
P n 3 8 3 = 0 0 5 0 0
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0
B B − J O G −
P n 3 8 3 = 0 1 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0
Keys Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn002.
Key to move through the list and
Press the Key. The display changes to the Fn002 execution display.
Press the Key to move the cursor to the setting side of Pn383 (JOG Speed).
Press the or Key and the or mm/s.
Key to set the JOG speed (Pn383) to 1000
6.3 JOG Operation (Fn002)
(cont’d)
Step
5
6
Display after Operation
B B − J O G −
P n 3 8 3 = 0 1 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0
R U N − J O G −
P n 3 8 3 = 0 1 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0
Keys
Press the Key.
Operation
The setting value is entered, and the cursor moves to the parameter number side (the left side).
Press the Key.
The status display changes from "BB" to "RUN", and the servomotor power turns ON.
The servomotor will move at the present speed set in
Pn383 while the Key (for forward run) or
Key (for reverse run) is pressed.
7
R U N − J O G −
P n 3 8 3 = 0 1 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0
Motor forward run
8
B B
−
J O G
−
P n 3 8 3 = 0 1 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0
Motor reverse run
After having confirmed the correct motion of servomotor, press the Key.
The status display changes from "RUN" to "BB", and the servomotor power turns OFF.
9
B B − F U N C T I O N −
F n 0 0 0 : A l m H i s t o r y
F n 0 0 2 : J O G
F n 0 0 3 : Z − S e a r c h
F n 0 0 4 : P r o g r a m J O G
Press the Key.
The display returns to the main menu of the utility function.
10 To enable the setting, turn the power supply to the SERVOPACK OFF and ON again.
6
6-5
6-6
6 Utility Functions (Fn )
6.4
Origin Search (Fn003)
The origin search is designed to position the origin pulse position of the incremental linear scale (phase C) and to clamp at the position.
CAUTION
• The forward run prohibited (P-OT) and reverse run prohibited (N-OT) signals are not effective in origin search mode.
This function is used when the servomotor needs to be aligned to the machine.
Motor speed at the time of execution: 15 mm/s
(1) Preparation
The following conditions must be met to perform the origin search.
• The write prohibited setting (Fn010) must be set to Write permitted (P.0000).
• The main circuit power supply must be ON.
• All alarms must be cleared.
• The hardwire baseblock (HWBB) must be disabled.
• The servomotor power must be OFF.
6.4 Origin Search (Fn003)
(2) Operating Procedure
Use the following procedure.
Step Display after Operation
1
B B − F U N C T I O N −
F n 0 0 2 : J O G
F n 0 0 3 : Z − S e a r c h
F n 0 0 4 : P r o g r a m J O G
F n 0 0 5 : P r m I n i t
Keys Operation
Press the ity function.
Key to view the main menu for the util-
Use the or select Fn003.
Key to move through the list and
2
B B − Z − S e a r c h −
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 3 = 0 0 0 0 0 0 0 0 7 7 4
U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0
Press the Key. The display changes to the Fn003 execution display.
3
4
5
R U N − Z − S e a r c h −
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 3 = 0 0 0 0 0 0 0 0 7 7 4
U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0
R U N − C o m p l e t e −
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 3 = 0 0 0 0 0 0 0 0 0 0 0
U n 0 0 D = 0 0 0 0 0 0 0 1 D 5 8
B B
−
Z
−
S e a r c h
−
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 3 = 0 0 0 0 0 0 0 0 0 0 0
U n 0 0 D = 0 0 0 0 0 0 0 1 D 5 8
Press the Key.
The status display changes from "BB" to "RUN", and the servomotor power turns ON.
Note: If the servomotor is already at the zero position,
"-Complete-" is displayed.
Pressing the Key will run the servomotor in the forward direction. Pressing the Key will run the servomotor in the reverse direction. The movement direction of the servomotor changes according to the setting of Pn000.0 as shown in the following table.
Parameter Key Key n.
n.
0
1
Linear scale counting up
Linear scale counting down
Pn000
Linear scale counting down
Linear scale counting up
Note: Forward movement is the linear scale counting up direction. For details, refer to 4.3.1 Servomotor Movement Direction .
Press the or Key until the servomotor stops.
If the origin search completed normally, "-Complete-" is displayed on the right top on the screen.
When the origin search is completed, press the
Key.
The status display changes from "RUN" to "BB", and the servomotor turns OFF. The display "-Complete-" changes to "-Z-Search-."
6
B B
−
F U N C T I O N
−
F n 0 0 2 : J O G
F n 0 0 3 : Z − S e a r c h
F n 0 0 4 : P r o g r a m J O G
F n 0 0 5 : P r m I n i t
Press the Key.
The display returns to the main menu of the utility function.
7 To enable the setting, turn the power supply to the SERVOPACK OFF and ON again.
6
6-7
6-8
6 Utility Functions (Fn )
6.5
Program JOG Operation (Fn004)
The program JOG operation is a utility function, that allows continuous operation determined by the preset operation pattern, movement distance, movement speed, acceleration/deceleration time, waiting time, and number of times of movement.
This function can be used to move the servomotor without it having to be connected to a host controller for the machine as a trial operation in JOG operation mode. Program JOG operation can be used to confirm the operation and for simple positioning operations.
(1) Preparation
The following conditions must be met to perform the program JOG operation.
• The write prohibited setting (Fn010) must be set to Write permitted (P.0000).
• The main circuit power supply must be ON.
• All alarms must be cleared.
• The hardwire baseblock (HWBB) must be disabled.
• The servomotor power must be OFF.
• The travel distance and speed must be set correctly considering the machine operation range and safe operation speed.
• There must be no overtravel.
(2) Additional Information
• The functions that are applicable for position control can be used. However, parameters related to motion control through MECHATROLINK communications (i.e., Pn800 and higher) are disabled.
• The overtravel function is enabled in this function.
(3) Program JOG Operation Patterns
A program JOG operation pattern is shown here. This program JOG operation pattern shows when the moving direction of the servomotor is set as Pn000.0 = 0 (Sets the linear scale counting up direction as the forward direction.).
(Waiting time Pn535
Pn530.0 = 0
→ Forward movement Pn531) × Number movements Pn536
Number of times of movement Pn536
Speed
Diagram
Movement speed
Pn585
Pn531
Movement distance
At zero speed
Press the key.
Waiting time
Pn535
Accel/Decel time
Pn534
Waiting time
Pn535
Pn531
Movement distance
Waiting time
Pn535
Pn531
Movement distance
Servomotor
Run Status
(Stop) (Forward) (Stop) (Forward) (Stop) (Forward)
Note: When Pn536 (number of times of program JOG movement) is set to 0, infinite time operation is enabled. To stop infinite time operation, press the JOG/SVON Key to turn OFF the servomotor power.
6.5 Program JOG Operation (Fn004)
(Waiting time Pn535
Pn530.0 = 1
→ Reverse movement Pn531) × Number of movements Pn536
Number of movements Pn536
Speed
Diagram
At zero speed
Movement speed
Pn585
Pn531
Movement distance
Pn531
Movement distance
Pn531
Movement distance
Press the
Key.
Waiting time
Accel/Decel time
Pn534
Pn535
Waiting time
Pn535
Waiting time
Pn535
Servomotor
Run Status
(Stop) (Reverse) (Stop) (Reverse) (Stop) (Reverse)
Note: When Pn536 (Number of Times of Program JOG Movement) is set to 0, infinite time operation is enabled. To stop infinite time operation, press the JOG/SVON Key to turn the servomotor power OFF.
Pn530.0 = 2
(Waiting time Pn535 → Forward movement Pn531) × Number of movements Pn536
(Waiting time Pn535 → Reverse movement Pn531) × Number of movements Pn536
Number of movements Pn536 Number of movements Pn536
Speed
Diagram
Movement speed
Pn585
At zero speed
Pn531
Movement distance
Press the
Key.
Waiting time
Pn535
Accel/Decel time
Pn534
Waiting time
Pn535
Pn531
Movement distance
Waiting time
Pn535
Accel/Decel time
Pn534
Waiting time
Pn535
Pn531
Movement distance
Pn531
Movement distance
Movement speed
Pn585
Servomotor
Run Status
(Stop) (Forward) (Stop) (Forward) (Stop) (Reverse) (Stop) (Reverse)
Note: When3 Pn530.0 is set to 2, infinite time operation is disabled.
(Waiting time Pn535
Pn530.0 = 3
→ Reverse movement Pn531) × Number of movements Pn536
(Waiting time Pn535 → Forward movement Pn531) × Number of movements Pn536
Number of movements Pn536 Number of movements Pn536
Speed
Diagram
Press the
Key.
Waiting time
Pn535
Accel/Decel time
Pn534
Waiting time
Pn535
At zero speed
Pn531
Movement distance
Pn531
Movement distance
Waiting time
Pn535
Pn531
Movement distance
Movement speed
Pn585
Accel/Decel time
Pn534
Waiting time
Pn535
Pn531
Movement distance
Movement speed
Pn585
Servomotor
Run Status
(Stop) (Reverse) (Stop) (Reverse) (Stop) (Forward) (Stop) (Forward)
Note: When Pn530.0 is set to 3, infinite time operation is disabled.
6
6-9
6-10
6 Utility Functions (Fn )
(Waiting time Pn535
Pn530.0 = 4
→ Forward movement Pn531 → Waiting time Pn535 → Reserve movement Pn531)
× Number of movements Pn536
Number of movements Pn536
Speed
Diagram
Pn531
Movement distance
At zero speed
Press the
Key.
Waiting time
Pn535
Waiting time
Accel/Decel time Pn535
Pn534
Movement speed
Pn585
Pn531
Movement distance
Pn585
Movement speed
Servomotor
Run Status
(Stop) (Forward) (Stop) (Reverse) (Stop)
Note: When Pn536 (number of times of program JOG movement) is set to 0, infinite time operation is enabled. To stop infinite time operation, press the JOG/SVON Key to turn OFF the servomotor power.
(Waiting time Pn535
Pn530.0 = 5
→ Reverse movement Pn531 → Waiting time Pn535 → Forward movement Pn531)
× Number of movements Pn536
Number of movements Pn536
Speed
Diagram
Press the
Waiting time
Pn535
Key.
Accel/Decel time
Pn534
Waiting time
Pn535
At zero speed
Pn531
Movement distance
Movement speed
Pn585
Pn531
Movement distance
Movement speed
Pn585
Servomotor
Run Status
(Stop) (Reverse) (Stop) (Forward) (Stop)
Note: When Pn536 (number of times of program JOG movement) is set to 0, infinite time operation is enabled. To stop infinite time operation, press the JOG/SVON Key to turn the servomotor power OFF.
(4) Related Parameters
The following parameters set the program JOG operation pattern. Do not change the settings while the program JOG operation is being executed.
Pn530
Pn531
Program JOG Operation Related Switch
Setting Range
0000 to 0005
Setting Unit
−
Speed
Factory Setting
0000
Position Force
When Enabled
Immediately
Program JOG Movement Distance
Setting Range
1 to 1073741824
Setting Unit
1 reference unit
Speed Position
Factory Setting
32768
Force
When Enabled
Immediately
Classification
Setup
Classification
Setup
6.5 Program JOG Operation (Fn004)
(cont’d)
Pn585
Pn534
Pn535
Program JOG Movement Speed Speed
Setting Range
1 to 10000
Setting Unit
1 mm/s
Factory Setting
50
Position Force
When Enabled
Immediately
Program JOG Acceleration/Deceleration Time
Setting Range
2 to 10000
Setting Unit
1 ms
Speed Position
Factory Setting
100
Force
When Enabled
Immediately
Program JOG Waiting Time Speed
Setting Range
0 to 10000
Setting Unit
1 ms
Factory Setting
100
Position Force
When Enabled
Immediately
Classification
Setup
Classification
Setup
Classification
1
B B − F U N C T I O N −
F n 0 0 3 : Z − S e a r c h
F n 0 0 4 : P r o g r a m J O G
F n 0 0 5 : P r m I n i t
F n 0 0 6 : A l m H i s t C l r
Setup
Pn536
Number of Times of Program JOG Movement Speed
Setting Range
0 to 1000
Setting Unit
1 time
Factory Setting
1
Position Force
When Enabled
Immediately
Classification
Setup
(5) Operating Procedure
Use the following procedure to perform the program JOG operation after setting a program JOG operation pattern.
Step Display after Operation Keys Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn004.
Key to move through the list and
2
B B
−
P R G J O G
−
P n 5 3 1 = 0 0 0 3 2 7 6 8
P n 5 3 4 = 0 0 1 0 0
P n 5 3 6 = 0 0 0 1 0
P n 5 8 5 = 0 0 0 5 0
Press the Key. The display changes to the Fn004 execution display.
3
*
B B − P R G J O G −
P n 5 3 1 = 0 0 0 3 2 7 6 8
P n 5 3 4 = 0 0 1 0 0
P n 5 3 6 = 0 0 0 1 0
P n 5 8 5 = 0 0 0 5 0
Confirm that the parameters have been set.
Press the Key to view Pn530.
Press the Key to view the parameters in the following order: Pn530 → Pn531 → Pn534 → Pn535 →
Pn536 → Pn585.
4
R U N − P R G J O G −
P n 5 3 1 = 0 0 0 3 2 7 6 8
P n 5 3 4 = 0 0 1 0 0
P n 5 3 6 = 0 0 0 1 0
P n 5 8 5 = 0 0 0 5 0
Press the Key.
The status display changes from "BB" to "RUN", and the servomotor power turns ON.
5
R U N − P R G J O G −
P n 5 3 1 = 0 0 0 3 2 7 6 8
P n 5 3 4 = 0 0 1 0 0
P n 5 3 6 = 0 0 0 1 0
P n 5 8 5 = 0 0 0 5 0
Press the (forward movement start) or
(reverse movement start) Key according to the first movement direction of the preset operation pattern.
The servomotor starts moving after the preset waiting time in Pn535.
Note:
Pressing the Key again changes the status to
"BB" (baseblocked status) and stops movement even during operation.
When the set program JOG operation movement is completed, "END" is displayed for one second, and then "RUN" is displayed.
6
R U N
−
P R G J O G
−
P n 5 3 1 = 0 0 0 3 2 7 6 8
P n 5 3 4 = 0 0 1 0 0
P n 5 3 6 = 0 0 0 1 0
P n 5 8 5 = 0 0 0 5 0
Press the Key. The servomotor becomes baseblocked status. The display returns to the main menu of the utility function.
7 To enable the setting, turn the power supply to the SERVOPACK OFF and ON again.
∗ The settings can be changed for a parameter.
6
6-11
6-12
6 Utility Functions (Fn )
6.6
Initializing Parameter Settings (Fn005)
This function is used when returning to the factory settings after changing parameter settings.
• Be sure to initialize the parameter settings while the servomotor power is OFF .
• After initialization, turn OFF the power supply and then turn ON again to validate the settings.
Note: Any value adjusted with Fn00C, Fn00D, Fn00E, and Fn00F cannot be initialized by Fn005.
(1) Preparation
The following conditions must be met to initialize the parameter values.
• The write prohibited setting (Fn010) must be set to Write permitted (P.0000).
• The servomotor power must be OFF.
(2) Operating Procedure
Use the following procedure.
Step Display after Operation Keys
1
B B − F U N C T I O N −
F n 0 0 4 : P r o g r a m J O G
F n 0 0 5 : P r m I n i t
F n 0 0 6 : A l m H i s t C l r
F n 0 0 C : M o n Z e r o A d j
Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn005.
Key to move through the list and
2
B B
P a r a m e t e r l n i t
S t a r t : [ D A T A ]
R e t u r n : [ S E T ]
Press the Key. The display changes to the Fn005 execution display.
3
B B
P a r a m e t e r l n i t
S t a r t : [ D A T A ]
R e t u r n : [ S E T ]
Press the Key to initialize parameters.
During initialization, "Parameter Init" is flashing in the display.
After the initialization is completed, "Parameter Init" stops flashing and the status display changes as follows: "BB" to "DONE" to "BB."
Note:
Press the Key not to initialize parameters. The display returns to the main menu of the utility function.
4 To enable the setting, turn the power supply to the SERVOPACK OFF and ON again.
6.7 Clearing Alarm History (Fn006)
6.7
Clearing Alarm History (Fn006)
The clear alarm history function deletes all of the alarm history recorded in the SERVOPACK.
Note: The alarm history is not deleted when the alarm reset is executed or the main circuit power supply of the SERVO-
PACK is turned OFF.
(1) Preparation
The follow conditions must be met to clear the alarm history.
• The write prohibited setting (Fn010) must be set to Write permitted (P.0000).
(2) Operating Procedure
Use the following procedure.
Step Display after Operation Keys
1
B B − F U N C T I O N −
F n 0 0 5 : P r m I n i t
F n 0 0 6 : A l m H i s t C l r
F n 0 0 C : M o n Z e r o A d j
F n 0 0 D : M o n G a i n A d j
Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn006.
Key to move through the list and
2
B B
A l a r m H i s t o r y
D a t a C l e a r
S t a r t : [ D A T A ]
R e t u r n : [ S E T ]
Press the Key to display the Fn006 (clearing alarm history) execution screen.
3
B B
A l a r m H i s t o r y
D a t a C l e a r
S t a r t : [ D A T A ]
R e t u r n : [ S E T ]
Press the Key to clear the alarm history.
While clearing the data, "DONE" is displayed in the status display. After the data has been successfully cleared, "BB" is displayed.
Note:
Press the Key not to clear the alarm history. The display returns to the main menu of the utility function.
6
6-13
6-14
6 Utility Functions (Fn )
6.8
Offset Adjustment of Analog Monitor Output (Fn00C)
This function is used to manually adjust the offsets for the analog monitor outputs (force reference monitor output and motor speed monitor output). The offset values are factory-set before shipping. Therefore, the user need not usually use this function.
(1) Adjustment Example
An example of offset adjustment to the motor speed monitor is shown below.
Analog monitor output voltage
Offset adjustment
Motor speed
Item
Offset Adjustment Range
Adjustment Unit
Specifications
-2.4 to + 2.4 V
18.9 mV/LSB
Note:
• The adjustment value will not be initialized when parameter settings are initialized using Fn005.
• Make offset adjustment with a measuring instrument connected, so that the analog monitor output is zero. An example of settings for a zero analog monitor output is shown below.
• While the servomotor is not turned ON, set the monitor signal to the force reference.
• In speed control, set the monitor signal to the position error.
(2) Preparation
The following condition must be met to adjust the offsets of the analog monitor output.
• The write prohibited setting (Fn010) must be set to Write permitted (P.0000).
6.8 Offset Adjustment of Analog Monitor Output (Fn00C)
(3) Operating Procedure
Use the following procedure to perform the offset adjustment of analog monitor output.
Step Display after Operation Keys
1
B B − F U N C T I O N −
F n 0 0 6 : A l m H i s t C l r
F n 0 0 C : M o n Z e r o A d j
F n 0 0 D : M o n G a i n A d j
F n 0 0 E : C u r A u t o A d j
Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn00C.
Key to move through the list and
2
B B − Z e r o A D J −
C H 1 = − 0 0 0 0 2
C H 2 = − 0 0 0 0 1
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
Press the Key. The display changes to the Fn00C execution display.
3
4
5
6
B B − Z e r o A D J −
C H 1 = − 0 0 0 0 5
C H 2 = − 0 0 0 0 1
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
B B
−
Z e r o A D J
−
C H 1 = − 0 0 0 0 5
C H 2 = − 0 0 0 0 1
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
B B − Z e r o A D J −
C H 1 = − 0 0 0 0 5
C H 2 = − 0 0 0 0 6
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
B B − Z e r o A D J −
C H 1 = − 0 0 0 0 5
C H 2 = − 0 0 0 0 6
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
Press the or Key to adjust the offset of CH1
(force reference monitor).
Adjust the offset so that the measurement instrument reading is as close to 0 V as possible.
After the offset adjustment of CH1 has completed, adjust the offset of CH2 (motor moving speed monitor).
Press the Key. The cursor moves to CH2 side.
Adjust the offset of CH2 in the same way as for CH1.
Press the
CH2.
or Key to adjust the offset of
Adjust the offset so that the measurement instrument reading is as close to 0 V as possible.
After having completed the offset adjustment both for
CH1 and CH2, press the Key.
The adjustment results are saved in the SERVO-
PACK, and the status display shows "DONE" for one second. The status display then returns to show "BB" again.
7
B B − F U N C T I O N −
F n 0 0 6 : A l m H i s t C l r
F n 0 0 C : M o n Z e r o A d j
F n 0 0 D : M o n G a i n A d j
F n 0 0 E : C u r A u t o A d j
Press the Key.
The display returns to the main menu of the utility function.
6
6-15
6-16
6 Utility Functions (Fn )
6.9
Gain Adjustment of Analog Monitor Output (Fn00D)
This function is used to manually adjust the gains for the analog monitor outputs (force reference monitor output and motor moving speed monitor output). The gain values are factory-set before shipping. Therefore, the user need not usually use this function.
(1) Adjustment Example
An example of gain adjustment to the motor moving speed monitor is shown below.
Analog monitor output voltage
1 [V]
Gain adjustment
1000 [mm/s]
Motor speed
Item
Gain-adjustment Range
Adjustment Unit
Specifications
100 ± 50%
0.4%/LSB
The gain adjustment range is made with a 100% output set as a center value (adjustment range: 50% to 150%).
The following is a setting example.
<Setting the Set Value to − 125>
100% + ( − 125 × 0.4) = 50%
Therefore, the monitor output voltage is 0.5 time as high.
<Setting the Set Value to 125>
100% + (125 × 0.4) =150%
Therefore, the monitor output voltage is 1.5 times as high.
Note: The adjustment value will not be initialized when parameter settings are initialized using Fn005.
(2) Preparation
The following condition must be met to adjust the gain of the analog monitor output.
• The write prohibited setting (Fn010) must be set to Write permitted (P.0000).
6.9 Gain Adjustment of Analog Monitor Output (Fn00D)
(3) Operating Procedure
Use the following procedure to perform the gain adjustment of analog monitor output.
Step Display after Operation Keys
1
B B − F U N C T I O N −
F n 0 0 C : M o n Z e r o A d j
F n 0 0 D : M o n G a i n A d j
F n 0 0 E : C u r A u t o A d j
F n 0 0 F : C u r M a n u A d j
Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn00D.
Key to move through the list and
2
B B − G a i n A D J −
C H 1 = − 0 0 0 0 1
C H 2 = − 0 0 0 0 1
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
Press the Key. The display changes to the Fn00D execution display.
3
4
5
6
7
B B
−
G a i n A D J
−
C H 1 = − 0 0 1 2 5
C H 2 = − 0 0 0 0 1
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
B B − G a i n A D J −
C H 1 =
−
0 0 1 2 5
C H 2 = − 0 0 0 0 1
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
B B − G a i n A D J −
C H 1 = − 0 0 1 2 5
C H 2 = − 0 0 1 2 5
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
B B
−
G a i n A D J
−
C H 1 = − 0 0 1 2 5
C H 2 = − 0 0 1 2 5
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
B B − F U N C T I O N −
F n 0 0 C : M o n Z e r o A d j
F n 0 0 D : M o n G a i n A d j
F n 0 0 E : C u r A u t o A d j
F n 0 0 F : C u r M a n u A d j
Press the or Key to adjust the gain adjustment width of CH1 (force reference monitor).
After the gain adjustment of CH1 has completed, adjust the gain adjustment width of CH2 (motor moving speed monitor).
Press the Key. The cursor moves to CH2 side.
Adjust the gain of CH2 in the same way as for CH1.
Press the or ment width of CH2.
Key to adjust the gain adjust-
After having completed the adjustment both for CH1 and CH2, press the Key.
The adjustment results are saved in the SERVO-
PACK, and the status display shows "DONE" for one second. The status display then returns to show "BB" again.
Press the Key.
The display returns to the main menu of the utility function.
6
6-17
6-18
6 Utility Functions (Fn )
6.10
Automatic Offset-Signal Adjustment of the Motor Current
Detection Signal (Fn00E)
Perform this adjustment only if highly accurate adjustment is required for reducing force ripple caused by current offset. The user need not usually use this function.
• Be sure to perform this function while the servomotor power is OFF.
• Execute the automatic offset adjustment if the force ripple is too big when compared with those of other SERVOPACKs.
Note: The adjusted value is not initialized by executing the Fn005 function (Initializing Parameter Settings).
(1) Preparation
The following conditions must be met to automatically adjust the offset of the motor current detection signal.
• The write prohibited setting (Fn010) must be set to Write permitted (P.0000).
• The SERVOPACK must be in Servo Ready status (Refer to 4.8.4
).
• The servomotor power must be OFF.
(2) Operating Procedure
Use the following procedure.
Keys Step
1
Display after Operation
B B − F U N C T I O N −
F n 0 0 D : M o n G a i n A d j
F n 0 0 E : C u r A u t o A d j
F n 0 0 F : C u r M a n u A d j
F n 0 1 0 : P r m P r o t e c t
2
B B
A u t o O f f s e t
−
A D J
o f M o t o r C u r r e n t
S t a r t : [ D A T A ]
R e t u r n : [ S E T ]
3
B B
A u t o O f f s e t − A D J
o f M o t o r C u r r e n t
S t a r t : [ D A T A ]
R e t u r n : [ S E T ]
Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn00E.
Key to move through the list and
Press the Key. The display changes to the Fn00E execution display.
Press the Key to start the automatic offset-signal adjustment of motor current detection.
When the adjustment is completed, the status display shows "DONE" for one second. The status display then returns to show "BB" again.
Note: Press the Key to cancel the automatic adjustment. The display returns to the main menu of the utility function.
6.11 Manual Offset-Signal Adjustment of the Motor Current Detection Signal (Fn00F)
6.11
Manual Offset-Signal Adjustment of the Motor Current
Detection Signal (Fn00F)
Use this function only if the force ripple is still high after the automatic offset-signal adjustment of the motor current detection signal (Fn00E).
If this function is adjusted incorrectly and then executed, characteristics of the servomotor performance could be affected.
Observe the following precautions when performing manual servo tuning.
• Run the servomotor at a speed of approximately 100 mm/s.
• Adjust the offset while monitoring the force reference with the analog monitor until the ripple of force reference monitor's waveform is minimized.
• Adjust the phase-U and phase-V offset amounts alternately several times until these offsets are well balanced.
Note: The adjusted value is not initialized by executing the Fn005 function (Initializing Parameter Settings).
(1) Preparation
The following condition must be met to manually adjust the offset of the motor current detection signal.
• The write prohibited setting (Fn010) must be set to Write permitted (P.0000).
(2) Operating Procedure
Use the following procedure.
Step Display after Operation Keys
1
B B − F U N C T I O N −
F n 0 0 F : C u r M a n u A d j
F n 0 1 0 : P r m P r o t e c t
F n 0 1 1 : M o t o r I n f o
F n 0 1 2 : S o f t V e r
Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn00F.
Key to move through the list and
2
B B
M a n u a l O f f s e t − A D J
o f M o t o r C u r r e n t
Z A D J I U = - 0 0 0 0 9
Z A D J I V = - 0 0 0 0 6
Press the Key.
The display changes to the Fn00F execution display.
3
R U N
M a n u a l O f f s e t − A D J
o f M o t o r C u r r e n t
Z A D J I U = - 0 0 0 0 9
Z A D J I V = - 0 0 0 0 6
− Send an SV_ON command from the host controller.
4
R U N
M a n u a l O f f s e t − A D J
o f M o t o r C u r r e n t
Z A D J I U = - 0 0 0 1 9
Z A D J I V = - 0 0 0 0 6
First, adjust the phase-U offset.
Press the or Key to change the offset.
Change the set value in increments of 10 in the direction where the force ripple decreases, and when you find the value where the force ripple is minimized, set that value.
Adjustment range: -512 to +511
5
R U N
M a n u a l O f f s e t − A D J
o f M o t o r C u r r e n t
Z A D J I U = - 0 0 0 1 9
Z A D J I V = - 0 0 0 0 6
Press the key to move the cursor to the V-phase offset (ZADJIV).
6
R U N
M a n u a l O f f s e t − A D J
o f M o t o r C u r r e n t
Z A D J I U = - 0 0 0 1 9
Z A D J I V = - 0 0 0 1 6
Next, adjust the phase-V offset.
Press the or Key to change the offset.
In the same way you adjusted the phase-U offset, change the set value in increments of 10 in the direction where the force ripple decreases, and when you find the value where the force ripple is minimized, set that value.
Adjustment range: -512 to +511
6
6-19
6-20
6 Utility Functions (Fn )
(cont’d)
Step
7
Display after Operation
R U N
M a n u a l O f f s e t − A D J
o f M o t o r C u r r e n t
Z A D J I U = - 0 0 0 1 9
Z A D J I V = - 0 0 0 1 6
Keys Operation
Press the key to move the cursor to the U-phase offset (ZADJIU).
8
R U N
M a n u a l O f f s e t − A D J
o f M o t o r C u r r e n t
Z A D J I U = - 0 0 0 2 4
Z A D J I V = - 0 0 0 2 1
Repeat steps 4 through 7 a number of times using a smaller amount of change than was previously used* to make fine adjustments to the offsets.
9
R U N
M a n u a l O f f s e t
−
A D J
o f M o t o r C u r r e n t
Z A D J I U = - 0 0 0 1 9
Z A D J I V = - 0 0 0 1 6
Press the Key to save the result of adjustment in the SERVOPACK.
When the saving is completed, the status display shows "DONE" for one second. The status display then returns to show "RUN" again.
10
R U N − F U N C T I O N −
F n 0 0 F : C u r M a n u A d j
F n 0 1 0 : P r m P r o t e c t
F n 0 1 1 : M o t o r I n f o
F n 0 1 2 : S o f t V e r
Press the Key.
The display returns to the main menu of the utility function.
∗ Examples of the amount to adjust the offsets
• First time: Increments of 10
• Second time: Increments of 5
• Third time: Increments of 1
The above values are a rough guide. Adjust the amount to adjust the offset and the number of times to repeat the changes according to your system.
6.12 Write Prohibited Setting (Fn010)
6.12
Write Prohibited Setting (Fn010)
This function prevents changing parameters by mistake and sets restrictions on the execution of the utility function.
Parameter changes and execution of the utility function become restricted in the following manner when Write prohibited (P.0001) is assigned to the write prohibited setting (Fn010).
• Parameters: Cannot be changed. If you attempt to change it, "NO-OP" will flash on the display and the screen will return to the main menu.
• Utility Function: Some functions cannot be executed. (Refer to the following table.) If you attempt to execute these utility functions, "NO-OP" will flash on the display and the screen will return to the main menu.
Fn030
Fn080
Fn200
Fn201
Fn202
Fn203
Fn204
Fn205
Fn206
Fn207
Fn010
Fn011
Fn012
Fn014
Fn01B
Fn01E
Fn020
Parameter
No.
Fn000
Fn002
Fn003
Fn004
Fn005
Fn006
Fn00C
Fn00D
Fn00E
Fn00F
Function
Alarm history display
JOG operation
Origin search
Program JOG operation
Initializing parameter settings
Clearing alarm history
Offset adjustment of analog monitor output
Gain adjustment of analog monitor output
Automatic offset-signal adjustment of the motor current detection signal
Manual offset-signal adjustment of the motor current detection signal
Write prohibited setting
Servomotor model display
Software version display
Resetting configuration error in option modules
Vibration detection level initialization
Display of SERVOPACK and servomotor ID
Origin setting
Software reset
Polarity Detection
Tuning-less levels setting
Advanced autotuning
Advanced autotuning by reference
One-parameter tuning
Anti-resonance control adjustment function
Vibration suppression function
EasyFFT
Online vibration monitor
Write Prohibited
Setting
Executable
Cannot be executed
Cannot be executed
Cannot be executed
Cannot be executed
Cannot be executed
Cannot be executed
Cannot be executed
Cannot be executed
Cannot be executed
–
Executable
Executable
Cannot be executed
Cannot be executed
Executable
Cannot be executed
Executable
Cannot be executed
Cannot be executed
Cannot be executed
Cannot be executed
Cannot be executed
Cannot be executed
Cannot be executed
Cannot be executed
Cannot be executed
Reference
Section
6.2
6.3
6.4
6.5
6.6
6.7
6.8
6.9
6.10
6.11
6.19
6.20
5.2.2
5.3.2
5.4.2
5.5.2
5.6.2
5.7.2
6.21
6.22
6.12
6.13
6.14
6.15
6.16
6.17
6.18
6
6-21
6-22
6 Utility Functions (Fn )
(1) Preparation
There are no tasks that must be performed before the execution.
(2) Operating Procedure
Follow the steps to set enable or disable writing.
Setting values are as follows:
• " P.0000
" : Write permitted (Releases write prohibited mode.) [Factory setting]
• " P.0001
" : Write prohibited (Parameters become write prohibited from the next power ON.)
Step
1
Display after Operation
B B − F U N C T I O N −
F n 0 0 F : C u r M a n u A d j
F n 0 1 0 : P r m P r o t e c t
F n 0 1 1 : M o t o r I n f o
F n 0 1 2 : S o f t V e r
Keys Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn010.
Key to move through the list and
2
B B
P a r a m e t e r
W r i t e P r o t e c t
P . 0 0 0 0
Press the Key. The display changes to the Fn010 execution display.
3
B B
P a r a m e t e r
W r i t e P r o t e c t
P . 0 0 0 1
Press the or Key to select one of the following settings.
P.0000: Write permitted [Factory setting]
P.0001: Write prohibited
4
B B
P a r a m e t e r
W r i t e P r o t e c t
Press the Key. The setting value is written into the SERVOPACK, and the status display changes as follows: "BB" to "DONE" to "BB."
P . 0 0 0 1
5 To enable the setting, turn the power supply to the SERVOPACK OFF and ON again.
Note: To make the setting available, change the setting to P.0000 as shown in step 3.
6.13 Servomotor Model Display (Fn011)
6.13
Servomotor Model Display (Fn011)
This function is used to check the servomotor model, voltage, capacity, encoder type, and the number of divisions of linear scale’s pitch. If the SERVOPACK has been custom-made, you can also check the specification codes of SERVOPACKs.
(1) Preparation
There are no tasks that must be performed before the execution.
(2) Operating Procedure
Use the following procedure.
Step
1
Display after Operation
B B − F U N C T I O N −
F n 0 1 0 : P r m P r o t e c t
F n 0 1 1 : M o t o r I n f o
F n 0 1 2 : S o f t V e r
F n 0 1 4 : O p t I n i t
Keys Operation
Press the Key to view the main menu for the utility function.
Use the select Fn011.
or Key to move through the list and
2
Servomotor model
Servomotor capacity
40 Linear servomotor
Servomotor input voltage
B B
−
M o t o r l n f o
−
T Y P E 4 0 A C 2 0 0 V
4 0 0 W
E N C O D E R 0 1 8 b i t
Press the Key. The display changes to the Fn011 execution display and shows the information about the servomotor and linear scale being used.
Code
Encoder type
Type
00 Incremental
01 Absolute
No. of Divisions
Data Resolution
8
12
256
4096
3
B B
−
F U N C T I O N
−
F n 0 1 0 : P r m P r o t e c t
F n 0 1 1 : M o t o r I n f o
F n 0 1 2 : S o f t V e r
F n 0 1 4 : O p t I n i t
Press the Key. The display returns to the main menu of the utility function.
6
6-23
6-24
6 Utility Functions (Fn )
6.14
Software Version Display (Fn012)
Select Fn012 to check the SERVOPACK and encoder software version numbers.
(1) Preparation
There are no tasks that must be performed before the execution.
(2) Operating Procedure
Use the following procedure.
Step
1
2
Display after Operation
B B − F U N C T I O N −
F n 0 1 1 : M o t o r I n f o
F n 0 1 2 : S o f t V e r
F n 0 1 4 : O p t I n i t
F n 0 1 B : V i b l v l I n i t
B B − S o f t V e r −
D R I V E R
V e r . = 0 0 0 1
E N C O D E R
V e r . = 0 0 0 3
Keys Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn012.
Key to move through the list and
Press the Key. The display changes to the Fn012 execution display.
The software versions of the SERVOPACK and the connected encoder will appear.
Note:
If the servomotor is not connected, "Not connect" is displayed.
3
B B − F U N C T I O N −
F n 0 1 1 : M o t o r I n f o
F n 0 1 2 : S o f t V e r
F n 0 1 4 : O p t I n i t
F n 0 1 B : V i b l v l I n i t
Press the Key. The display returns to the main menu of the utility function.
6.15 Resetting Configuration Errors in Option Modules (Fn014)
6.15
Resetting Configuration Errors in Option Modules (Fn014)
The SERVOPACK with option module recognizes installation status and types of option modules that are connected to SERVOPACK. If an error is detected, the SERVOPACK issues an alarm. This function clears these alarms.
Note 1. Alarms related to option module can be cleared only by this function. These alarms cannot be cleared by alarm reset or turning OFF the main circuit power supply.
2. Before clearing the alarm, perform corrective action for the alarm.
(1) Preparation
The following condition must be met to clear detection alarms of the option module.
• The write prohibited setting (Fn010) must be set to Write permitted (P.0000).
(2) Operating Procedure
Use the following procedure.
Step Keys
1
Display after Operation
B B − F U N C T I O N −
F n 0 1 2 : S o f t V e r
F n 0 1 4 : O p t I n i t
F n 0 1 B : V i b l v l I n i t
F n 0 1 E : S v M o t O p I D
Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn014.
Key to move through the list and
2
B B − O p t I n i t −
0 2 : S a f e t y O p t
Press the Key. The display changes to the Fn014 execution display.
3
B B
−
O p t I n i t
−
0 2 : S a f e t y O p t
Press the to be cleared.
or Key to select an option module
4
B B − O p t I n i t −
S a f e t y O p t
I n i t i a l i z e
S t a r t : [ D A T A ]
R e t u r n : [ S E T ]
Press the appears.
Key. The display shown on the left
5
B B − O p t I n i t −
0 2 : S a f e t y O p t
Press the Key to clear the configuration error of the option module.
The error is cleared and the status display shows
"DONE" for one second. The status display then returns to step 3.
6
B B − F U N C T I O N −
F n 0 1 2 : S o f t V e r
F n 0 1 4 : O p t I n i t
F n 0 1 B : V i b l L v l I n i t
F n 0 1 E : S v M o t O p I D
Press the Key. The display returns to the main menu of the utility function.
7 To enable the setting, turn the power supply to the SERVOPACK OFF and ON again.
6
6-25
6-26
6 Utility Functions (Fn )
6.16
Vibration Detection Level Initialization (Fn01B)
This function detects vibration when servomotor is connected to a machine in operation and automatically adjusts the vibration detection level (Pn384) to output more exactly the vibration alarm (A.520) and the vibration warning (A.911).
The vibration detection function detects vibration elements according to the motor speed.
Parameter n.
0
[Factory setting]
Meaning
Does not detect vibration.
When Enabled Classification
Pn310 n.
1
Outputs the warning (A.911) when vibration is detected.
Outputs the alarm (A.520) when vibration is detected.
Immediately Setup n.
2
If the vibration exceeds the detection level calculated by the following formula, the alarm or warning will be output according to the setting of vibration detection switch (Pn310).
Detection level =
Vibration detection level (Pn384 [mm/s])
ޓ
×
Vibration detection sensitivity (Pn311 [%])
100
• Use this function if the vibration alarm (A.520) or the vibration warning (A.911) is not output correctly when a vibration at the factory setting of the vibration detection level (Pn384) is detected. In other cases, it is not necessary to use this function.
• The vibration alarm or warning detection sensibility differs depending on the machine conditions. In this case, fine-tune the setting of the vibration detection sensitivity (Pn311) using the above detection level formula as a guide.
Pn311
Vibration Detection Sensitivity
Setting Range
50 to 500
Setting Unit
1%
Speed Position
Factory Setting
100
Force
When Enabled
Immediately
Classification
Tuning
• The vibration may not be detected because of improper servo gains. Also, not all kinds of vibrations can be detected. Use the detection result as a guideline.
• Set a proper mass ratio (Pn103). Improper setting may result in the vibration alarm, warning misdetection, or non-detection.
• The references that are used to operate your system must be input to execute this function.
• Execute this function under the operating condition for which the vibration detection level should be set.
• Execute this function while the motor speed reaches at least 10% of its maximum.
(1) Preparation
The following conditions must be met to initialize the vibration detection level.
• The write prohibited setting (Fn010) must be set to Write permitted (P.0000).
• The test without a motor function must be disabled (Pn00C.0 = 0).
6.16 Vibration Detection Level Initialization (Fn01B)
(2) Operating Procedure
Use the following procedure.
Step Display after Operation
1
R U N − F U N C T I O N −
F n 0 1 4 : O p t I n i t
F n 0 1 B : V i b l v l I n i t
F n 0 1 E : S v M o t O p I D
F n 0 2 0 : S − O r i g S e t
2
R U N
V i b r a t i o n D e t e c t
L e v e l I n i t
S t a r t : [ D A T A ]
R e t u r n : [ S E T ]
Keys Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn01B.
Key to move through the list and
Press the Key. The display changes to the Fn01B execution display.
3
R U N
V i b r a t i o n D e t e c t
L e v e l I n i t
I n i t
Press the Key.
"Init" is displayed flashing, and the vibration level is detected and initialized.
Note:
Continues initialization until the Key is pressed again.
4
R U N
V i b r a t i o n D e t e c t
L e v e l I n i t
D 㧻 㧺 㧱
Press the Key. The display changes from "Init" to "DONE," for one second and the new setting of
Pn384 becomes enabled.
5
R U N − F U N C T I O N −
F n 0 1 4 : O p t I n i t
F n 0 1 B : V i b l v l I n i t
F n 0 1 E : S v M o t O p I D
F n 0 2 0 : S − O r i g S e t
Press the Key. The display returns to the main menu of the utility function.
(3) Related Parameters
The following table lists parameters related to this function and their possibility of being changed while executing this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes: Parameters can be changed using SigmaWin+ while this function is being executed.
No: Parameters cannot be changed using SigmaWin+ while this function is being executed.
• Automatic changes after execution of this function
Yes: Parameter set values are automatically set or adjusted after execution of this function.
No: Parameter set values are not automatically set or adjusted after execution of this function.
Parameter
Pn311
Pn384
Name
Vibration Detection Sensitivity
Vibration Detection Level
Mid-execution changes
Yes
No
Automatic changes
No
Yes
6
6-27
6-28
6 Utility Functions (Fn )
6.17
Display of SERVOPACK and Servomotor ID (Fn01E)
This function displays ID information for SERVOPACK, servomotor, linear scale, and option module connected to the SERVOPACK. The ID information of some option modules is not stored in the SERVOPACK.
"Not available" will be displayed for these option modules.
The digital operator (model: JUSP-OP05A-1-E) or SigmaWin+ engineering tool is required to execute this function.
Refer to Σ -V Series User's Manual, Operation of Digital Operator procedure of the digital operator.
(No.: SIEP S800000 55) for the operating
The following items can be displayed.
Safety Option Module
ID
*
ID
SERVOPACK ID
Servomotor ID
Encoder ID
Feedback Option Module ID
*
Items to be Displayed
• SERVOPACK model
• SERVOPACK serial number
• SERVOPACK manufacturing date
• SERVOPACK input voltage (V)
• Maximum applicable motor capacity (W)
• Maximum applicable motor rated current (Arms)
• Servomotor model
• Servomotor order number
• Servomotor manufacturing date
• Servomotor input voltage (V)
• Servomotor capacity (W)
• Servomotor rated current (Arms)
• Linear scale model
• Linear scale or serial converter unit serial number
• Linear scale or serial converter unitmanufacturing date
• Linear scale type/resolution
• Safety Option Module model
• Safety Option Module serial number
• Safety Option Module manufacturing date
• Safety Option Module ID number
• Feedback Option Module model
• Feedback Option Module serial number (Reserved area)
• Feedback Option Module manufacturing date
• Feedback Option Module ID
∗ If the option module is not connected, "Not connect" will be displayed after the module name.
(1) Preparation
There are no tasks that must be performed before the execution.
6.17 Display of SERVOPACK and Servomotor ID (Fn01E)
(2) Operating Procedure
Use the following procedure.
Step Display after Operation
1
R U N
−
F U N C T I O N
−
F n 0 1 B : V i b l v l I n i t
F n 0 1 E : S v M o t O p I D
F n 0 2 0 : S − O r i g S e t
F n 0 3 0 : S o f t R e s e t
2
3
4
Serial number
SERVOPACK model
B B − S v M o t O p I D −
D r i v e r
S G D V
−
R 7 0 A 1 5 A
D 0 0 2 4 1 2 3 4 5 9 0 0 0 1
0 7 . 0 4 2 0 0 V , 5 0 W
Manufacturing date
SERVOPACK input voltage
Motor capacity
Motor order number
Servomotor model
B B
−
S v M o t O p I D
−
M o t o r
S G L G W − 3 0 A 0 5 0 C
1 2 3 4 5 6 7 8 9 0 0 0 0 0 0
0 7 . 0 4 2 0 0 V , 4 0 W
Motor manufacturing date
Motor input voltage
Motor capacity
Linear scale or serial converter unit serial number
Linear scale model
B B ࠉ − S v M o t O p I D −
E n c o d e r
J Z D P
−
D 0 0 3
−
0 0 0
0 0 0 0 0 0 − 0 0 0 − 0 0 0 0 0
0 7 . 0 4 8 b i t − I N C
Linear scale or
Linear scale resolution serial converter unit manufacturing date
Linear scale type
5
R U N
−
F U N C T I O N
−
F n 0 1 B : V i b l v l I n i t
F n 0 1 E : S v M o t O p I D
F n 0 2 0 : S − O r i g S e t
F n 0 3 0 : S o f t R e s e t
Keys Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn01E.
Key to move through the list and
Press the Key.
The display changes to the Fn01E execution display.
The SERVOPACK ID information is displayed. Use the or Key to scroll left and right and to view other information.
Press the Key.
The servomotor ID information is displayed. Use the
or Key to scroll left and right and to view other information.
Press the Key.
The linear scale ID information is displayed.
Use the or Key to scroll left and right and to view other information.
Press the Key.
The display returns to the main menu of the utility function.
6
6-29
6-30
6 Utility Functions (Fn )
6.18
Origin Setting (Fn020)
This function is used to set the current position of an absolute linear scale as the origin (zero point position).
This function can be used with the following products.
Mitutoyo Corporation
ABS ST780A series
Model: ABS ST78 A/ST78 AL
• After execution of origin setting, the servo ready (/S-RDY) signal will turn OFF (open) because the system position data will have been changed. Always turn the power supply to the SERVOPACK OFF and ON again.
• After execution of origin setting, the servomotor phase data in the SERVOPACK will be discarded. Execute polarity detection (Fn080) again to save the servomotor phase data in the SERVOPACK.
(1) Preparation
The following conditions must be met to set the origin.
• The write prohibited setting (Fn010) must be set to Write permitted (P.0000).
• The servomotor power must be OFF.
(2) Operating Procedure
Use the following procedure.
Step Keys
1
Display after Operation
B B − F U N C T I O N −
F n 0 2 0 : S − O r i g S e t
F n 0 3 0 : S o f t R e s e t
F n 0 8 0 : P o l e D e t e c t
F n 2 0 0 : T u n e L v l S e t
Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn020.
Key to move through the list and
2
B B
S c a l e O r i g i n S e t
O R G S E T 1
Press the Key. The display changes to the Fn020 execution display.
B B
3
S c a l e O r i g i n S e t
Press the or Key to "ORGSET5".
O R G S E T 5
4
B B
S c a l e O r i g i n S e t
Press the key to start setting the origin. The message, "Scale Origin Set," flashes while the origin is being set. After the origin has been successfully set, the displayed status changes as follows: "BB" to
"DONE" to "BB".
5 To enable the setting, turn the power supply to the SERVOPACK OFF and ON again.
6.19 Software Reset (Fn030)
6.19
Software Reset (Fn030)
This function enables resetting the SERVOPACK internally from software. This function is used when resetting alarms and changing the settings of parameters that normally require restarting the SERVOPACK.
Parameters settings can also be enabled without turning the SERVOPACK OFF and ON again.
• Start software reset operation after the servomotor power is OFF.
• This function resets the SERVOPACK independently of host controller. The SERVO-
PACK carries out the same processing as when the power supply is turned ON and outputs the ALM signal. The status of other output signals may be forcibly changed.
(1) Preparation
The following condition must be met to perform a software reset.
• The servomotor power must be OFF.
(2) Operating Procedure
Use the following procedure.
Step Display after Operation Keys
1
B B − F U N C T I O N −
F n 0 2 0 : S − O r i g S e t
F n 0 3 0 : S o f t R e s e t
F n 0 8 0 : P o l e D e t e c t
F n 2 0 0 : T u n e L v l S e t
Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn030.
Key to move through the list and
2
B B
S o f t w a r e R e s e t
R E S E T 1
Press the Key. The display changes to the Fn030 execution display.
3
4
B B
S o f t w a r e R e s e t
R E S E T 5
B B
S o f t w a r e R e s e t
Press the or Key to select "RESET5".
Press the Key to execute the software reset.
After the software reset starts, "RESET5" will no longer be displayed.
5
F i l e F i r s t L o a d i n g
P l e a s e W a i t . . .
−
After the reset has been successfully completed, the screen which appears when the power is turned ON will be displayed. The screen will then show parameters or monitor displays.
6
B B − F U N C T I O N −
F n 0 2 0 : S − O r i g S e t
F n 0 3 0 : S o f t R e s e t
F n 0 8 0 : P o l e D e t e c t
F n 2 0 0 : T u n e L v l S e t
Press the Key.
The display returns to the main menu of the utility function.
6
6-31
6-32
6 Utility Functions (Fn )
6.20
Polarity Detection (Fn080)
The polarity detection function is used to detect the polarity and save the servomotor phase data in the SER-
VOPACK.
(1) Preparation
The following conditions must be met to detect the polarity.
• The write prohibited setting (Fn010) must be set to Write permitted (P.0000).
• The main circuit power supply must be ON.
• No alarms have occurred except A.C22.
• The hardwire baseblock (HWBB) must be disabled.
• The servomotor power must be OFF.
(2) Operating Procedure
Use the following procedure.
Step
1
Display after operation
B B − F U N C T I O N −
F n 0 3 0 : S o f t R e s e t
F n 0 8 0 : P o l e D e t e c t
F n 2 0 0 : T u n e L v l S e t
F n 2 0 1 : A A T
2
㧮㧮
ޓ㧹㨍㨓㨚㨑㨠㨕㨏ޓ㧼㨛㨘㨑
ޓޓޓޓޓ㧰㨑㨠㨑㨏㨠
ޓ㧸㨑㨢㨑㨘㧩㧠㧜
3
4
B B
M a g n e t i c P o l e
D e t e c t
S t a r t : [ J O G S V O N ]
R e t u r n : [ S E T ]
P D E T
M a g n e t i c P o l e
A d j u s t m e n t
R e t u r n : [ S E T ]
5
6
B B
M a g n e t i c P o l e
D e t e c t
R e t u r n : [ S E T ]
B B − F U N C T I O N −
F n 0 3 0 : S o f t R e s e t
F n 0 8 0 : P o l e D e t e c t
F n 2 0 0 : T u n e L v l S e t
F n 2 0 1 : A A T
Keys
−
Operation
Press the ity function.
Key to view the main menu of the util-
Use the or and select Fn080.
Key to move through the list
Press the Key .
The display changes to the Fn080 execution display.
To adjust the level:
or Key to move the cursor from/ Press the to the digit.
Press the each digit.
or Key to change the value of
Press the appear.
Key. The display shown on the left will
Press the Key. The servomotor will be in servo
ON status and the polarity detection will start. During the polarity detection, “Magnetic Pole Adjustment” is displayed flashing. When the polarity detection is complete, the servomotor will be in servo OFF status.
When the polarity detection is complete, the display shown on the left will appear.
Press the Key. The display returns to the main menu of the utility function.
6.21 EasyFFT (Fn206)
6.21
EasyFFT (Fn206)
EasyFFT sends a frequency waveform reference from the SERVOPACK to the servomotor and slightly moves the servomotor several times over a certain period, thus causing machine vibration. The SERVOPACK detects the resonance frequency from the generated vibration and makes notch filter settings according to the resonance frequency detection. The notch filter is effective for the elimination of high-frequency vibration and noise.
Execute this function after the servomotor power is turned OFF if there is high-frequency vibration or noise during operation.
WARNING
• The servomotor moves slightly when EasyFFT is executed. Do not touch the servomotor or machine during execution of EasyFFT, otherwise injury may result.
CAUTION
• Use the EasyFFT when the servo gain is low, such as in the initial stage of servo adjustment. If EasyFFT is executed after increasing the gain, the servo system may vibrate depending on the machine characteristics or gain balance.
Periodic waveform reference
Response
Slight movement
SERVOPACK
In addition to this function, online vibration monitor (Fn207) can be used to detect machine vibration and automatically make notch filter settings.
If a Σ -V Series SERVOPACK is used to make adjustments, it is recommended to use advanced autotuning.
This built-in EasyFFT function is used to maintain interchangeability with previous models. There is normally no need to use it.
(1) Preparation
The following conditions must be met to perform EasyFFT.
• The write prohibited setting (Fn010) must be set to Write permitted (P.0000).
• The main circuit power supply must be ON.
• All alarms must be cleared.
• The hardwire baseblock (HWBB) must be disabled.
• The servomotor power must be OFF.
• There must be no overtravel.
• The test without a motor function must be disabled (Pn00C.0 = 0).
• An external reference must not be input.
(2) Operating Procedure
Use the following procedure.
6
6-33
6-34
6 Utility Functions (Fn )
Step
1
2
Display after Operation
B B − F U N C T I O N −
F n 2 0 5 : V i b S u p
F n 2 0 6 : E a s y F F T
F n 2 0 7 : V - M o n i t o r
F n 0 0 0 : A l m H i s t o r y
B B
−
E a s y F F T
−
S e t t i n g
I n p u t = 0 1 5 %
3
4
5
6
B B − E a s y F F T −
S e t t i n g
I n p u t = 0 1 5 %
R U N − E a s y F F T −
R e a d y
I n p u t = 0 1 5 %
R U N
−
E a s y F F T
−
M e a s u r e
I n p u t = 0 1 5 %
B B − E a s y F F T −
R e s u l t
I n p u t = 0 1 5 %
R e s = 1 2 5 0 H z
F i l t e r 1 1 2 5 0 H z
Keys Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn206.
Key to move through the list and
Press the Key. The display changes to the Fn206 execution display.
The cursor is on the setting of "Input." Press the or Key to set the sweep force reference amplitude (Pn456)
Setting range: 1 to 800.
Note:
When making the initial settings for EasyFFT, do not change the setting for the reference amplitude. Start with the original value of 15. Increasing reference amplitude increases the detection accuracy, but the vibration and noise from the machine will increase.
Increase the amplitude value little by little.
Press the Key to turn the servomotor power ON.
The display “BB” and “Setting” changes to “RUN” and “Ready.”
Press the (forward run start) Key or
(reverse run start) Key to run the servomotor and start the frequency measurement. "Measure" is displayed during the measurement.
Within 10 mm, the servomotor will move forward and then in reverse several times.
Notes:
• Press the Key to cancel the measurement. The servomotor stops moving and the power turns OFF.
The detection of the resonance frequency is not completed.
• The actions of the servomotor are very minute in this operation. Also at the same time, the servomotor emits a noise. To ensure safety, do not enter the working envelope of the motor.
When the detection processing is successfully completed, "Measure" stops flashing and the results and the notch filter value to be set are displayed. If the processing was not completed, "No Measure" is displayed. To check the results, go to step 8.
< Important >
If two seconds or more are required for the operation although detection was successfully completed, the detection accuracy might be insufficient. Increasing reference amplitude more than 15 increases the detection accuracy, but the vibration and noise from the machine will increase. Increase the amplitude value little by little.
Notes:
• If a notch filter has been set and is being used, "*" is displayed on the second line.
• If the first stage notch filter has been set, the second stage notch filter value is displayed. If the first and second stage notch filters have been set, only the result of frequency detection is displayed.
6.21 EasyFFT (Fn206)
Step
7
Display after Operation
B B − E a s y F F T −
R e a d y
I n p u t = 0 1 5 %
Keys
(cont’d)
Operation
To exit the EasyFFT function at this stage, press the Key. The power to the servomotor is turned
OFF and the display returns to the main menu of the utility function.
To remeasure the resonance frequency, press the
Key to return to step 4 and then execute steps 5 to 7.
8
D 㧻 㧺 㧱 − E a s y F F T −
R e s u l t
I n p u t = 0 1 5 %
R e s = 1 2 5 0 H z
F i l t e r 1 1 2 5 0 H z
Press the Key after the normal completion of frequency detection. The notch filter frequencies are automatically updated to the optimum values.
The status display shows "DONE" and the display shown on the left appears.
If the first stage notch filter frequency has been set
(Pn408.0 = 1), the second stage notch filter frequency
(Pn 40C) will automatically be updated.
Notes:
• If the first stage or the second stage notch filter frequency has already been set (Pn408 = n.
1 1), the notch filter frequency cannot be set.
• If the frequency detected by this function is not used, set the notch filter to be invalid (Pn408.0 =
0).
9
B B − F U N C T I O N −
F n 2 0 5 : V i b S u p
F n 2 0 6 : E a s y F F T
F n 2 0 7 : V - M o n i t o r
F n 0 0 0 : A l m H i s t o r y
Press the Key.
The servomotor enters a baseblocked status. The display returns to the main menu of the utility function.
10 To enable the setting, turn the power supply to the SERVOPACK OFF and ON again.
(3) Related Parameters
The following table lists parameters related to this function and their possibility of being changed while executing this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes : Parameters can be changed using SigmaWin+ while this function is being executed.
No : Parameters cannot be changed using SigmaWin+ while this function is being executed.
• Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
Parameter
Pn408
Pn409
Pn40A
Pn40C
Pn40D
Pn456
Name
Force Related Function Switch
1st Notch Filter Frequency
1st Notch Filter Q Value
2nd Notch Filter Frequency
2nd Notch Filter Q Value
Sweep Force Reference Amplitude
Mid-execution changes
Yes
No
No
No
No
No
Automatic changes
Yes
Yes
No
Yes
No
No
6
6-35
6-36
6 Utility Functions (Fn )
6.22
Online Vibration Monitor (Fn207)
If vibration is generated during operation and this function is executed while the servomotor power is still ON, the machine vibration can sometimes be suppressed by setting a notch filter or force reference filter for the vibration frequencies.
When online, vibration frequency caused by machine resonance will be detected and the frequency that has the highest peak will be displayed on the panel operator. The effective force reference filter or notch filter frequency for the vibration frequencies will be automatically selected and the related parameters will be automatically set.
In addition to this function, EasyFFT (Fn206) can be used to detect machine vibration and automatically make notch filter settings. Use the following flowchart to determine how these functions should be used.
If a Σ -V Series SERVOPACK is used to make adjustments, it is recommended that you use advanced autotuning. This built-in function is used to maintain interchangeability with previous models. There is normally no need to use it.
How to use EasyFFT (Fn206) and online vibration monitor (Fn207), when they are mainly used for servo gain adjustment.
Start
Vibration with high-frequency noise
during operation
Yes
Turn OFF the servomotor power, and execute EasyFFT (Fn206)
No
Adjust servo gain
No
Vibration
Yes
With the servomotor power ON, execute online vibration monitor (Fn207)
End
(1) Preparation
The following conditions must be met to perform online vibration monitoring.
• The write prohibited setting (Fn010) must be set to Write permitted (P.0000).
• The servomotor power must be ON.
• There must be no overtravel.
• The correct mass (Pn103) must be set.
• The test without a motor function must be disabled (Pn00C.0 = 0).
6.22 Online Vibration Monitor (Fn207)
(2) Operating Procedure
Use the following procedure.
Step
1
2
Display after Operation
R U N − F U N C T I O N −
F n 2 0 6 : E a s y F F T
F n 2 0 7 : V − M o n i t o r
F n 0 0 0 : A l m H i s t o r y
F n 0 0 1 : J O G
R U N − V − M O N I T O R −
M e a s u r e
F 1 = − − − −
F 2 = − − − −
F 3 = − − − −
3
R U N − V − M O N I T O R −
M e a s u r e
F 1 = − − − −
F 2 = − − − −
F 3 = − − − −
4
R U N − V − M O N I T O R −
M e a s u r e
F 1 = 0 8 5 0 [ H z ]
F 2 = 1 6 0 0 [ H z ]
F 3 = 0 2 2 5 [ H z ]
5
D O N E − V − M O N I T O R −
S E T T I N G D O N E
F 1 = 0 8 5 0 [ H z ]
F 2 = 1 6 0 0 [ H z ]
F 3 = 0 2 2 5 [ H z ]
6
R U N − F U N C T I O N −
F n 2 0 6 : E a s y F F T
F n 2 0 7 : V − M o n i t o r
F n 0 0 0 : A l m H i s t o r y
F n 0 0 1 : J O G
Keys Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn207.
Key to move through the list and
Press the Key.
The display changes to the Fn207 execution display.
Press the Key for at least one second to start vibration detection. The Key must be pressed until "Measure" flashes on the display.
Note:
After this message appears, the Key does not have to be pressed and the detection continues automatically.
When the vibration detection has completed, "Measure" stops flashing and the detection processing ends automatically. When the detection processing has completed normally, the vibrations with three largest peak values in vibration frequency are displayed for
F1, F2, and F3.
Notes:
• Press the Key to quit the online vibration monitor function. The display returns to the main menu of the utility function.
• A detected frequency can be displayed. For a vibration with undetectable peak frequency, "----" is displayed. If no frequency was detected, "----" is displayed for F1, F2, and F3.
• If the frequency could not be successfully detected,
"NO MONITOR" is displayed.
After the detection has normally completed, press the
Key. The optimum frequency (time constant) of notch filter or force reference filter for F1 is set automatically. At the same time, the parameter Pn409 is updated for a notch filter, or the parameter Pn401 is updated for a force reference filter.
After the setting is successfully completed, "DONE" flashes.
Press the Key.
The display returns to the main menu of the utility function.
6
6-37
6-38
6 Utility Functions (Fn )
(3) Related Parameters
The following table lists parameters related to this function and their possibility of being changed while executing this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes : Parameters can be changed using SigmaWin+ while this function is being executed.
No : Parameters cannot be changed using SigmaWin+ while this function is being executed.
• Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
Parameter
Pn401
Pn408
Pn409
Pn40A
Pn40C
Pn40D
Name
Force Reference Filter Time Constant
Force Related Function Switch
1st Notch Filter Frequency
1st Notch Filter Q Value
2nd Notch Filter Frequency
2nd Notch Filter Q Value
Mid-execution changes
No
Yes
No
No
No
No
Automatic changes
Yes
Yes
Yes
No
No
No
7
Monitor Displays (Un
)
7.1 List of Monitor Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
7.2 Viewing Monitor Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3
7.3 Monitoring Input Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4
7.3.1 Interpreting Input Signal Display Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4
7.3.2 Input Signal Display Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-5
7.4 Monitoring Output Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6
7.4.1 Interpreting Output Signal Display Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6
7.4.2 Output Signal Display Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6
7.5 Monitoring Safety Input Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7
7.5.1 Interpreting Safety Input Signal Display Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7
7.5.2 Safety Input Signal Display Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7
7
7-1
7-2
7 Monitor Displays (Un )
7.1
List of Monitor Displays
The monitor displays can be used for monitoring the I/O signal status, and SERVOPACK internal status.
Refer to the following table.
Un010
Un011
Un012
Un013
Un014
Un015
Un020
Un021
Parameter
No.
Un000
Un001
Un002
Un003
Un004
Un005
*2
Un006
*3
Un007
Un008
Un009
Un00A
Un00B
Un00C
Un00D
Un022
Un084
Un085
*4
Description Unit
Motor moving speed
Speed reference
Internal force reference (percentage of the rated force)
Electric angle 1 (number of linear-scale pulses from polarity origin: decimal display)
Electric angle 2 (from polarity origin) mm/s mm/s
% linear scale pulse deg
*1
Input signal monitor
Output signal monitor
Input reference pulse speed (valid only in position control)
Position error amount (valid only in position control)
Accumulated load ratio (in percentage to the rated force: effective force in cycle of 10 seconds)
−
− mm/s reference unit
%
Regenerative load ratio (as a percentage of the processable regenerative power: regenerative power consumption in cycle of 10 seconds)
Power consumed by DB resistance
(in percentage to the processable power at DB activation: displayed in cycle of 10 seconds)
%
%
Input reference pulse counter
Feedback pulse counter reference unit linear scale pulse
*1
Allowable motor maximum speed and encoder output resolution
−
Hall sensor signal
Total operation time
−
100 ms
Feedback pulse counter reference unit
Effective gain monitor (gain settings 1 = 1, gain settings 2 = 2) −
Safety I/O signal monitor −
Motor rated speed mm/s mm/s Motor maximum speed
Installation environment monitor
(Operation conditions in various environments can be monitored.)
%
Linear scale pitch (Scale pitch = Un084 × 10
Un085
[pm]) −
Linear scale pitch index (Scale pitch = Un084 × 10
Un085
[pm]) −
∗1.
For details, refer to 4.4.3 Electronic Gear .
∗2.
For details, refer to 7.3 Monitoring Input Signals .
∗3.
For details, refer to 7.4 Monitoring Output Signals .
∗4.
This monitor can be used only with SGDV B SERVOPACKs. For details, refer to 2 Installation in the
Σ -V Series User’s Manual, Setup, Linear Motor (No.: SIEP S800000 44).
7.2 Viewing Monitor Displays
7.2
Viewing Monitor Displays
The monitor display can be checked or viewed in the Parameter/Monitor (-PRM/MON-) window of the digital operator.
The following figure shows four factory settings that are first displayed if viewing monitor displays.
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㨁㨚㧜㧜㧜㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
Indicates that the value of Un000
(motor moving speed) is 0 mm/s.
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
To view any items that are not shown, press the or Key to scroll through the list.
Motor moving speed
㨁㨚㧜㧜㧜㧩ޓ㧜㧜㧜㧜㧜
Speed reference 㨁㨚㧜㧜㧝㧩ޓ㧜㧜㧜㧜㧜
Internal force reference
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
Electric angle 1 (number of linear-scale pulses from polarity origin)
㨁㨚㧜㧜㧟㧩ޓ㧜㧜㧜㧜㧜
Electric angle 2 (from polarity origin) 㨁㨚㧜㧜㧠㧩ޓ㧜㧜㧜㧥㧜
Feedback pulse counter 㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
7
7-3
7-4
7 Monitor Displays (Un )
7.3.1 Interpreting Input Signal Display Status
7.3
Monitoring Input Signals
The status of input signals can be checked with the input signal monitor (Un005). The procedure for the method of interpreting the display and a display example are shown below.
7.3.1
Interpreting Input Signal Display Status
The input signal monitor (Un005) can be read in the following way. The upper level indicates OFF, and the lower level indicates ON. All undefined digits are shown in the lower level (ON).
U n 0 0 5 =
8 7 6 5 4 3 2 1 digit
Display LED
Number
1
2
5
6
3
4
7
8
Input Terminal Name
CN1-13
CN1-7
CN1-8
CN1-9
CN1-10
CN1-11
CN1-12
–
<NOTE>
Input signals use the following circuit configuration.
OFF: Open
ON: Short-circuited
Example
Signal Name
(Factory Setting)
/SI0
P-OT
N-OT
/DEC
/EXT1
/EXT2
/EXT3
Reserved
OFF (open)
7.3.2
Input Signal Display Example
Input signals are displayed as shown below.
• When the /DEC signal is ON
U n 0 0 5 =
The fourth digit is in the lower level.
8 7 6 5 4 3 2 1 digit
• When the /DEC signal is OFF
The fourth digit is in the upper level.
U n 0 0 5 =
8 7 6 5 4 3 2 1 digit
• When the P-OT signal is activated
The second digit is in the upper level.
U n 0 0 5 =
8 7 6 5 4 3 2 1 digit
7.3 Monitoring Input Signals
7
7-5
7-6
7 Monitor Displays (Un )
7.4.1 Interpreting Output Signal Display Status
7.4
Monitoring Output Signals
The status of output signals can be checked with the output signal monitor (Un006). The procedure for the method of interpreting the display and a display example are shown below.
7.4.1
Interpreting Output Signal Display Status
The output signal monitor (Un006) can be read in the following way. The upper level indicates OFF, and the lower level indicates ON. All undefined digits are shown in the lower level (ON).
U n 0 0 6 =
8 7 6 5 4 3 2 1 digit
Display LED
Number
7
8
5
6
3
4
1
2
Output Terminal Name
CN1-3, -4
CN1-1, -2
CN1-23, -24
CN1-25, -26
−
−
−
−
<NOTE>
Output signals use the following circuit configuration.
OFF: Transistor OFF
ON: Transistor ON
Example
Signal Name
(Factory Setting)
ALM
/BK
SO2
SO3
Reserved
Reserved
Reserved
Reserved
ON: Transistor ON
7.4.2
Output Signal Display Example
Output signals are displayed as shown below.
• When the ALM signal is OFF
The first digit is in the upper level.
U n 0 0 6 =
8 7 6 5 4 3 2 1 digit
7.5 Monitoring Safety Input Signals
7.5
Monitoring Safety Input Signals
The status of safety input signals can be checked with the safety I/O signal monitor (Un015). The procedure for the method of interpreting the display and a display example are shown below.
7.5.1
Interpreting Safety Input Signal Display Status
The safety I/O signal monitor (Un015) can be read in the following way. The upper level indicates ON, and the lower level indicates OFF. All undefined digits are shown in the lower level (OFF).
U n 0 1 5 =
8 7 6 5 4 3 2 1 digit
Display LED Number
1
2
3
4
5
6
7
8
Input Terminal Name
CN8-3, -4
CN8-5, -6
−
−
−
−
−
−
Note: Input signals use the following circuit configuration.
• OFF: Open
• ON: Short-circuited
Example
Signal Name
/HWBB1
/HWBB2
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
ON (short-circuited)
7.5.2
Safety Input Signal Display Example
Safety input signals are displayed as shown below.
• When the /HWBB1 signal turns OFF to activate the HWBB function
The first digit is in the lower level.
U n 0 1 5 =
8 7 6 5 4 3 2 1 digit
7
7-7
8
Troubleshooting
8.1 Alarm Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
8.1.1 List of Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
8.1.2 Troubleshooting of Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6
8.2 Warning Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-24
8.2.1 List of Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-24
8.2.2 Troubleshooting of Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-25
8.3 Monitoring Communication Data on Occurrence of an Alarm or Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-29
8.4 Troubleshooting Malfunction Based on Operation and Conditions of the Servomotor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-30
8
8-1
8-2
8 Troubleshooting
8.1.1 List of Alarms
8.1
Alarm Displays
This section provides a list of the alarms that may occur and the causes of and corrections for those alarms.
8.1.1
List of Alarms
This section provides a list of alarm names, alarm meanings, stopping methods, and alarm reset capabilities in order of the alarm numbers.
Servomotor Stopping Method
If an alarm occurs, the servomotor can be stopped by doing either of the following operations.
Gr.1: The servomotor is stopped according to the setting in Pn001.0 if an alarm occurs. Pn001.0 is factory-set to stop the servomotor by applying the DB.
Gr.2: The servomotor is stopped according to the setting in Pn00B.1 if an alarm occurs. Pn00B.1 is factory-set to stop the servomotor by setting the speed reference to " 0.
" The servomotor under force control will always use the Gr.1 method to stop. By setting Pn00B.1 to 1, the servomotor stops using the same method as Gr.1. When coordinating a number of servomotors, use this stopping method to prevent machine damage that may result due to differences in the stop method.
Alarm Reset
Available:Removing the cause of alarm and then executing the alarm reset can clear the alarm.
N/A:Executing the alarm reset cannot clear the alarm.
Alarm
Number
Alarm Name Meaning
Servomotor
Stopping
Method
A.020
A.021
Parameter Checksum
Error 1
Parameter Format Error 1
A.022
System Checksum Error 1
The data of the parameter in the SERVOPACK is incorrect.
A.030
Main Circuit Detector Error Detection data for main circuit is incorrect.
A.040
Parameter Setting Error 1
The data of the parameter in the SERVOPACK is incorrect.
The data of the parameter in the SERVOPACK is incorrect.
A.041
Encoder Output Pulse
Setting Error
The parameter setting is outside the setting range.
The encoder output resolution (Pn281) is outside the setting range or does not satisfy the setting conditions.
A.042
Parameter Combination
Error
A.04A
Parameter Setting Error 2
A.0b0
Canceled Servo ON
Command Alarm
Combination of some parameters exceeds the setting range.
Bank member/bank data setting is incorrect.
A.050
Combination Error
The SERVOPACK and the servomotor capacities do not match each other.
A.051
Unsupported Device Alarm The device unsupported was connected.
A.080
Linear Scale Pitch Setting
Error
The setting of the linear scale pitch (Pn282) has not been changed from the default setting.
The servo ON command (SV_ON) was sent from the host controller after executing a utility function that turns ON servomotor.
A.100
Overcurrent or Heat Sink
Overheated
A.300
Regeneration Error
A.320
A.330
Regenerative Overload
Main Circuit Power
Supply Wiring Error
An overcurrent flowed through the IGBT or the heat sink of the SERVOPACK was overheated.
Regenerative circuit or regenerative resistor is faulty.
Regenerative energy exceeds regenerative resistor capacity.
• Setting of AC input/DC input is incorrect.
• Power supply wiring is incorrect.
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.2
Gr.1
Alarm
Reset
N/A
N/A
N/A
Available
N/A
N/A
N/A
N/A
Available
N/A
N/A
Available
N/A
Available
Available
Available
8.1 Alarm Displays
Alarm
Number
Alarm Name
A.400
Overvoltage
A.410
Undervoltage
A.450
Main-Circuit
Capacitor Overvoltage
A.510
Overspeed
A.511
Overspeed of Encoder
Output Pulse Rate
A.520
Vibration Alarm
A.521
Autotuning Alarm
A.550
Maximum Speed Setting
Error
A.710
Overload: High Load
A.720
Overload: Low Load
A.730
A.731
Dynamic Brake Overload
A.740
Overload of Surge
Current Limit Resistor
A.7A0
Heat Sink Overheated
A.7Ab
Built-in Fan in
SERVOPACK Stopped
A.820
Encoder Checksum Error
A.840
Encoder Data Error
A.850
Encoder Overspeed
A.860
Encoder Overheated
A.861
Motor Overheated
A.890
Encoder Scale Error
A.891
Encoder Module Error
A.b31
Current Detection Error 1
A.b32
Current Detection Error 2
A.b33
Current Detection Error 3
A.b6A
MECHATROLINK
Communications
ASIC Error 1
A.b6b
MECHATROLINK
Communications
ASIC Error 2
A.bE0
Firmware Error
A.bF0
System Alarm 0
A.bF1
System Alarm 1
Meaning
Main circuit DC voltage is excessively high.
Main circuit DC voltage is excessively low.
The capacitor of the main circuit has deteriorated or is faulty.
The servomotor speed is above the maximum speed.
The motor speed upper limit of the set encoder output resolution (Pn281) is exceeded.
Incorrect vibration at the motor speed was detected.
Vibration was detected while performing tuning-less function.
The Pn385 setting is greater than the maximum speed.
The servomotor was operating for several seconds to several tens of seconds under a force largely exceeding ratings.
The servomotor was operating continuously under a force exceeding ratings.
When the dynamic brake was applied, moving energy exceeded the capacity of dynamic brake resistor.
The main circuit power was frequently turned ON and OFF.
The heat sink of the SERVOPACK exceeded 100 ° C.
The fan inside the SERVOPACK stopped.
(cont’d)
Servomotor
Stopping
Method
Gr.1
Gr.2
Alarm
Reset
Available
Available
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.2
Gr.1
Gr.1
Gr.1
Gr.2
Gr.1
N/A
Available
Available
Available
Available
Available
Available
Available
Available
Available
Available
Available
The checksum results of linear scale memory is incorrect.
Data in the linear scale is incorrect.
The linear scale was moving at high speed when the power was turned ON.
The internal temperature of linear scale is too high.
The internal temperature of motor is too high.
A linear scale fault occurred
Linear scale is faulty.
The current detection circuit for phase U is faulty.
The current detection circuit for phase V is faulty.
The detection circuit for the current is faulty.
ASIC error occurred in the MECHATROLINK communications.
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
ASIC error occurred in the MECHATROLINK communications.
An internal program error occurred in the SERVO-
PACK.
Internal program error 0 occurred in the SERVO-
PACK.
Internal program error 1 occurred in the SERVO-
PACK.
Gr.2
Gr.1
Gr.1
Gr.1
N/A
N/A
N/A
N/A
8
8-3
8-4
8 Troubleshooting
8.1.1 List of Alarms
(cont’d)
Alarm
Number
Alarm Name Meaning
A.bF2
A.bF3
A.bF4
System Alarm 2
System Alarm 3
System Alarm 4
A.C10
Servo Overrun Detected
A.C20
Phase Detection Error
A.C21
Hall Sensor Error
A.C22
Phase Information
Disagreement
A.C50
Polarity Detection Error
A.C51
A.C52
A.C53
Overtravel Detection at Polarity Detection
Polarity Detection
Uncompleted
Out of Range for Polarity
Detection
A.C54
Polarity Detection Error 2
A.C80
Absolute Encoder Clear Error
A.C90
A.C91
Encoder Communications
Error
Encoder Communications
Position Data Error
A.C92
Encoder Communications
Timer Error
A.CA0
Encoder Parameter Error
Internal program error 2 occurred in the SERVO-
PACK.
Internal program error 3 occurred in the SERVO-
PACK.
Internal program error 4 occurred in the SERVO-
PACK.
The servomotor ran out of control.
The detection of the phase is incorrect.
The hall sensor is faulty.
The phase information does not match.
The polarity detection failed.
The overtravel signal was detected at polarity detection.
The servomotor was turned ON under the condition of polarity detection uncompleted.
The moving distance exceeded the set value of
Pn48E during polarity detection.
The polarity detection failed.
The absolute linear scale data was cleared or the setting is not correct.
Communications between the SERVOPACK and the linear scale is not possible.
A linear scale position data calculation error occurred.
A.Cb0
A.d00
Encoder Echoback Error
Position Error Overflow
An error occurs in the communications timer between the linear scale and the SERVOPACK.
Linear scale parameters are faulty.
Contents of communications with linear scale are incorrect.
Position error exceeded the value of excessive position error alarm level (Pn520) when the servomotor power is ON.
A.d01
A.d02
Position Error Overflow
Alarm at Servo ON
Position Error Overflow
Alarm by Speed Limit at Servo ON
This alarm occurs if the servomotor power is turned
ON when the position error is greater than the set value of Pn526 while the servomotor power is OFF.
When the position errors remain in the error counter,
Pn584 limits the speed if the servomotor power is turned ON. If Pn584 limits the speed in such a state, this alarm occurs when position references are input and the number of position errors exceeds the value set for the excessive position error alarm level
(Pn520).
The position feedback data exceeded ± 1879048192.
A.d30
Position Data Overflow
A.E02
MECHATROLINK
Internal Synchronization Error 1
A.E40
A.E50
MECHATROLINK
Transmission Cycle
Setting Error
MECHATROLINK
Synchronization Error
Synchronization error during MECHATROLINK communications with the SERVOPACK.
The setting of the MECHATROLINK transmission cycle is out of the allowable range.
A synchronization error occurs during
MECHATROLINK communications.
Servomotor
Stopping
Method
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.2
Gr.1
Gr.1
Gr.2
Gr.2
Alarm
Reset
N/A
N/A
N/A
Available
N/A
N/A
N/A
N/A
Available
Available
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Available
Available
Available
N/A
Available
Available
Available
8.1 Alarm Displays
(cont’d)
Alarm
Number
Alarm Name Meaning
Servomotor
Stopping
Method
Alarm
Reset
A.E51
A.E60
A.E61
A.E71
A.E74
A.E75
A.E81
*1
A.EA2
A.Eb1
MECHATROLINK
Synchronization Failed
MECHATROLINK
Communications Error (Reception error)
MECHATROLINK
Transmission Cycle Error
(Synchronization interval error)
Safety Option Module
Detection Failure
Unsupported Safety
Option Module
Unsupported Feedback Option Module
SERVOPACK: Safety Module Alarm
DRV Alarm 2
(SERVOPACK WDC error)
Safety Function Signal
Input Timing Error
A synchronization failure occurs in
MECHATROLINK communications.
A communications error occurs continuously during
MECHATROLINK communications.
The transmission cycle fluctuates during
MECHATROLINK communications.
Detection of the safety option module failed.
An unsupported safety option module was connected.
An unsupported feedback option module was connected.
–
A SERVOPACK DRV alarm 0 occurs.
The safety function signal input timing is faulty.
Gr.2
Gr.2
Gr.2
Gr.1
Gr.1
Gr.1
–
Gr.2
Gr.1
Available
Available
Available
N/A
N/A
N/A
–
Available
N/A
A.Eb
*1
A.EC
*1
SERVOPACK: Safety Module Alarms
– – –
A.Ed1
A.F10
A.F50
Command Execution
Timeout
Main Circuit Cable Open
Phase
Servomotor Main Circuit
Cable Disconnection
A timeout error occurred when using a
MECHATROLINK command.
A low voltage continued for one second or longer in either phase R, S, or T when the main circuit power supply was ON.
The servomotor did not operate or power was not supplied to the servomotor even though the SV_ON
(Servo ON) command was input when the servomotor was ready to receive it.
Gr.2
Gr.2
Gr.1
Available
Available
Available
FL-1
*2
System Alarm Internal program error occurred in the SERVOPACK − N/A
FL-2 *2
CPF00
CPF01
Digital Operator
Transmission Error 1
Digital Operator
Transmission Error 2
Communications cannot be performed between the digital operator (model: JUSP-OP05A-1-E) and the
SERVOPACK (CPU error or other error).
− N/A
∗1.
These alarms occur in SERVOPACKs with safety modules. For details, refer to the
User's Manual Safety Module (Manual No. SIEP C720829 06).
Σ -V Series AC Servo Drives
∗2.
These alarms are not saved in the alarm history. There are displayed only on the panel display.
8
8-5
8-6
8 Troubleshooting
8.1.2 Troubleshooting of Alarms
8.1.2
Troubleshooting of Alarms
Refer to the following table to identify the cause of an alarm and the action to be taken.
Contact your Yaskawa representative if the problem cannot be solved by the described corrective action.
Alarm Number:
Alarm Name
Cause Investigative Actions Corrective Actions
The power supply voltage suddenly dropped.
Measure the power supply voltage.
Set the power supply voltage within the specified range, and set Fn005 to initialize the parameter.
The power supply went OFF while changing a parameter setting.
Check the circumstances when the power supply went OFF.
Set Fn005 to initialize the parameter and then set the parameter again.
A.020:
Parameter Checksum
Error 1
(The parameter data in the SERVOPACK is incorrect.)
The number of times that parameters were written exceeded the limit.
Malfunction caused by noise from the AC power supply or grounding line, static electricity noise, etc.
Gas, water drops, or cutting oil entered the SERVOPACK and caused failure of the internal components.
Check to see if the parameters were frequently changed through the host controller.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the cause may be noise.
Check the installation conditions.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
Reconsider the method of writing parameters.
Take countermeasures against noise.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
A SERVOPACK fault occurred.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
A.021:
Parameter Format
Error 1
(The parameter data in the SERVOPACK is incorrect.)
A.022:
System Checksum
Error 1
(The parameter data in the SERVOPACK is incorrect.)
The software version of SERVO-
PACK that caused the alarm is older than that of the written parameter.
Check Fn012 to see if the set software version agrees with that of the
SERVOPACK. If not, an alarm may occur.
A SERVOPACK fault occurred.
−
The power supply voltage suddenly dropped.
The power supply went OFF while setting an utility function.
A SERVOPACK fault occurred.
Measure the power supply voltage.
Check the circumstances when the power supply went OFF.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty.
Write the parameter of another
SERVOPACK of the same model with the same software version.
Then turn the power OFF and then
ON again.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
A.030:
Main Circuit Detector
Error
A SERVOPACK fault occurred.
−
The SERVOPACK may be faulty.
Replace the SERVOPACK.
A.040:
Parameter Setting
Error 1
(The parameter setting was out of the setting range.)
A.041:
Encoder Output Pulse
Setting Error
The SERVOPACK and servomotor capacities do not match each other.
Check the combination of SERVO-
PACK and servomotor capacities.
A SERVOPACK fault occurred.
−
The parameter setting is out of the setting range.
The electronic gear ratio is out of the setting range.
Check the setting ranges of the parameters that have been changed.
Check the electronic gear ratio. The ratio must satisfy:
0.001< (Pn20E/Pn210) < 4000.
The encoder output resolution
(Pn281) is out of the setting range and does not satisfy the setting conditions.
Check the parameter Pn281.
Select the proper combination of
SERVOPACK and servomotor capacities.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
Set the parameter to a value within the setting range.
Set the electronic gear ratio in the range: 0.001< (Pn20E/Pn210)
< 4000.
Set Pn281 to a correct value.
8.1 Alarm Displays
Alarm Number:
Alarm Name
Cause Investigative Actions
A.042:
Parameter
Combination Error
A.04A:
Parameter Setting
Error 2
The speed of program JOG operation (Fn004) is lower than the setting range after having changed the electronic gear ratio
(Pn20E/Pn210) or the servomotor.
The speed of program JOG operation (Fn004) is lower than the setting range after having changed the setting of the program JOG movement speed
(Pn585).
The moving speed of advanced autotuning is lower than the setting range after having changed the electronic gear ratio (Pn20E/
Pn210) or the servomotor.
For a 4-byte parameter bank, no registration in two consecutive bytes for two bank members.
The total amount of bank data exceeds 64. (Pn900 × Pn901 >
64)
Check if the detection conditions are satisfied.
*1
Check if the detection conditions are satisfied.
*1
Check if the detection conditions are satisfied.
*2
–
–
A.050:
Combination Error
(The SERVOPACK and servomotor capacities do not correspond.)
The SERVOPACK and servomotor capacities do not match each other.
A linear scale fault occurred.
A SERVOPACK fault occurred.
−
Check the capacities to see if they satisfy the following condition:
1
4
≤
Servomotor capacity
SERVOPACK capacity
≤ 4
Replace the linear scale and see if the alarm occurs again.
A.051:
Unsupported Device
Alarm
The parameters of the motor parameter file are not written in the linear scale. (Only when not using serial converter units)
An unsupported serial converter unit or linear scale is connected to the SERVOPACK.
Check if the parameters of the motor parameter file are written in the linear scale.
Check the product specifications, and select the correct model.
A.080:
Linear Scale
Pitch Setting
Error
The setting of the linear scale pitch (Pn282) has not been changed from the default setting.
Check the value of Pn282.
(cont’d)
Corrective Actions
Decrease the setting of the electronic gear ratio (Pn20E/Pn210).
Increase the setting of the program
JOG movement speed (Pn585).
Decrease the setting of the electronic gear ratio (Pn20E/Pn210).
Change the number of bytes for bank members to an appropriate value.
Reduce the total amount of bank data to 64 or less.
Select the proper combination of
SERVOPACK and servomotor capacities.
Replace the linear scale.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
Write the parameters of the motor parameter file in the linear scale.
Select the correct combination of units.
Correct the value of Pn282.
∗1.
Detection conditions
If one of the following conditions is detected, an alarm occurs.
•
Pn585[mm/s]
Linear scale pitch [ μ m]
×
Number of divisions of serial converter unit
10
•
Pn385 [100 mm/s]
Linear scale pitch [ μ m]
×
Number of divisions of serial converter unit
About 6.10 × 10
5
≤
•
Pn385 [100 mm/s]
Linear scale pitch [ μ m]
×
Number of divisions of serial converter unit
About 6.10 × 10
5
∗2.
Detection conditions
If one of the following conditions is detected, an alarm occurs.
•
Rated motor speed [mm/s] × 1/3
Linear scale pitch [ μ m]
×
≥
Pn20E
Pn210
Number of divisions of serial converter unit
10
≤
Pn20E
Pn210
≥
Pn20E
Pn210
Pn20E
Pn210
8
8-7
8-8
8 Troubleshooting
8.1.2 Troubleshooting of Alarms
Alarm Number:
Alarm Name
A.0b0:
Canceled Servo ON
Command Alarm
A.100:
Overcurrent or Heat
Sink Overheated
(An overcurrent flowed through the IGBT or heat sink of SERVO-
PACK overheated.)
Cause Investigative Actions
(cont’d)
Corrective Actions
After executing the utility function to turn ON the power to the motor, the servo ON command
(SV_ON) was sent from the host controller.
Incorrect wiring or contact fault of main circuit cables.
−
Turn the SERVOPACK power supply OFF and then ON again or execute a software reset.
Short-circuit or ground fault of main circuit cables.
Short-circuit or ground fault inside the servomotor.
Short-circuit or ground fault inside the SERVOPACK.
Incorrect wiring or contact fault of the regenerative resistor.
The dynamic brake (DB: Emergency stop executed from the
SERVOPACK) was frequently activated, or the DB overload alarm occurred.
Check the wiring. Refer to 3.1
Main Circuit Wiring for details.
Check for short-circuits across the servomotor terminal phases U, V, and W, or between the grounding and servomotor terminal phases U,
V, or W. Refer to 3.1 Main Circuit
Wiring for details.
Check for short-circuits across the servomotor terminal phases U, V, and W, or between the grounding and servomotor terminal phases U,
V, or W. Refer to 3.1 Main Circuit
Wiring for details.
Check for short-circuits across the servomotor connection terminals U,
V, and W on the SERVOPACK, or between the grounding and terminal
U, V, or W. Refer to 3.1 Main Circuit Wiring for details.
Check the wiring. Refer to 3.7 Connecting Regenerative Resistors for details.
Check the power consumed by DB resistance (Un00B) to see how many times the DB has been used.
Or, check the alarm history display
Fn000 to see if the DB overload alarm A.730 or A.731 was reported.
Correct the wiring.
The cable may be short-circuited.
Replace the cable.
The servomotor may be faulty.
Replace the servomotor.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
Correct the wiring.
Change the SERVOPACK model, operating conditions, or the mechanism so that the DB does not need to be used so frequently.
The generated regenerative resistor value exceeded the SERVO-
PACK regenerative energy processing capacity.
Check the regenerative load ratio
(Un00A) to see how many times the regenerative resistor has been used.
Check the operating condition including overload, and reconsider the regenerative resistor value.
The SERVOPACK regenerative resistance is too small.
A heavy load was applied while the servomotor was stopped or running at a low speed.
Malfunction caused by noise interference.
A SERVOPACK fault occurred.
Check the regenerative load ratio
(Un00A) to see how many times the regenerative resistor has been used.
Check to see if the operating conditions are outside servo drive specifications.
Improve the wiring or installation environment, such as by reducing noise, and check to see if the alarm recurs.
−
Change the regenerative resistance value to a value larger than the
SERVOPACK minimum allowable resistance value.
Reduce the load applied to the servomotor or increase the operating speed.
Take countermeasures for noise, such as correct wiring of the FG.
Use an FG wire size equivalent to the SERVOPACK main circuit wire size.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
8.1 Alarm Displays
Alarm Number:
Alarm Name
A.300:
Regeneration Error
A.320:
Regenerative
Overload
(cont’d)
Cause Investigative Actions Corrective Actions
The regenerative resistor capacity
(Pn600) is set to a value other than 0 for a SGDV-R70F, -R90F,
-2R1F, -2R8F, -R70A, -R90A,
-1R6A, or -2R8A SERVOPACK, and an external regenerative resistor is not connected.
Check the external regenerative resistor connection and the value of the Pn600.
Connect the external regenerative resistor, or set Pn600 to 0 if no regenerative resistor is required.
An external regenerative resistor is not connected to the SGDV
-550A, -260D SERVOPACK.
Check the connection of the external regenerative resistor or the
Yaskawa regenerative resistor unit and the set value in Pn600.
Connect an external regenerative resistor and set Pn600 to the appropriate value, or connect a Yaskawa regenerative resistor unit and set
Pn600 to 0.
The lead wire between the B2 and
B3 terminals was removed when no External Regenerative Resistor was connected to the SGDV-
3R8A, -5R5A, -7R6A, -120A,
-180A, -200A, -330A, -1R9D,
-3R5D, -5R4D, -8R4D, -120D, or
-170D (when using the Regenerative Resistor built into the SER-
VOPACK).
Check the wiring of the lead wire between the B2 and B3 power supply terminals on the SERVOPACK.
Wire the B2 and B3 terminals with a lead wire.
The External Regenerative Resistor or Regenerative Resistor Unit is not wired correctly, or was removed or disconnected.
A SERVOPACK fault occurred.
Check the wiring of the External
Regenerative Resistor or Regenerative Resistor Unit.
−
Correct the wiring of the External
Regenerative Resistor or Regenerative Resistor Unit.
Note: The SERVOPACK will fail if the External Regenerative Resistor or Regenerative Resistor Unit is connected when the lead wire is wired between the B2 and B3 terminals.
Turn the SERVOPACK’s control power supply OFF and ON again while the main circuit power supply is OFF. If the alarm still occurs, the
SERVOPACK may be faulty.
Replace the SERVOPACK.
The power supply voltage exceeds the specified limit.
Insufficient external regenerative resistance, regenerative resistor capacity, or SERVOPACK capacity.
Or, regenerative power has been continuously flowing back.
Regenerative power continuously flowed back because negative load was continuously applied.
The setting of parameter Pn600 is smaller than the external regenerative resistor's capacity.
The external regenerative resistance is too high.
A SERVOPACK fault occurred.
Check the operating condition or the capacity using the capacity selection Software SigmaJunma-
Size+, etc.
Check the load applied to the servomotor during operation.
Change the regenerative resistance, regenerative resistor capacity, or
SERVOPACK capacity. Reconsider the operating conditions using the capacity selection software Sigma-
JunmaSize+, etc.
Reconsider the system including servo, machine, and operating conditions.
Check the external regenerative resistor connection and the value of the Pn600.
Set the Pn600 to a correct value.
Check the regenerative resistance.
−
Change the regenerative resistance to a correct value or use an external regenerative resistor of appropriate capacity.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
8
8-9
8-10
8 Troubleshooting
8.1.2 Troubleshooting of Alarms
(cont’d)
Alarm Number:
Alarm Name
Cause Investigative Actions Corrective Actions
A.330:
Main Circuit Power
Supply Wiring Error
(Detected when the main circuit power supply is turned ON.)
The regenerative resistor disconnected when the SERVOPACK power supply voltage was high.
In the AC power input mode, DC power was supplied.
In the DC power input mode, AC power was supplied.
The regenerative resistor capacity
(Pn600) is set to a value other than 0 for a SGDV-R70F, -R90F,
-2R1F, -2R8F, -R70A, -R90A,
-1R6A, or -2R8A SERVOPACK, and an external regenerative resistor is not connected.
An external regenerative resistor is not connected to the SGDV
-470A, -550A, -590A, -780A, -
210D, -260D, -280D, or -370D
SERVOPACK.
The lead wire between the B2 and
B3 terminals was removed when no External Regenerative Resistor was connected to the SGDV-
3R8A, -5R5A, -7R6A, -120A,
-180A, -200A, -330A, -1R9D,
-3R5D, -5R4D, -8R4D, -120D, or
-170D (when using the Regenerative Resistor built into the SER-
VOPACK).
Measure the resistance of the regenerative resistor using a measuring instrument.
Check the power supply to see if it is a DC power supply.
Check the power supply to see if it is an AC power supply.
Check the external regenerative resistor connection and the value of the Pn600.
Check the connection of the external regenerative resistor or the
Yaskawa regenerative resistor unit and the set value in Pn600.
Check the wiring of the lead wire between the B2 and B3 power supply terminals on the SERVOPACK.
When using a regenerative resistor built in the SERVOPACK:
Replace the SERVOPACK.
When using an external regenerative resistor:
Replace the external regenerative resistor.
Correct the settings to match the actual power supply specifications.
Correct the settings to match the actual power supply specifications.
Connect the external regenerative resistor, or set Pn600 to 0 if no external regenerative resistor is required.
Connect an external regenerative resistor and set Pn600 to the appropriate value, or connect a Yaskawa regenerative resistor unit and set
Pn600 to 0.
Wire the B2 and B3 terminals with a lead wire.
The External Regenerative Resistor or Regenerative Resistor Unit is not wired correctly, or was removed or disconnected.
A SERVOPACK fault occurred.
Check the wiring of the External
Regenerative Resistor or Regenerative Resistor Unit.
−
Correct the wiring of the External
Regenerative Resistor or Regenerative Resistor Unit.
Note: The SERVOPACK will fail if the External Regenerative Resistor or Regenerative Resistor Unit is connected when the lead wire is wired between the B2 and B3 terminals.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
8.1 Alarm Displays
(cont’d)
Alarm Number:
Alarm Name
Cause Investigative Actions Corrective Actions
A.400:
Overvoltage
(Detected in the SER-
VOPACK main circuit power supply section.)
A.410:
Undervoltage
(Detected in the SER-
VOPACK main circuit power supply section.)
• For 100-VAC SERVOPACKs:
The AC power supply voltage exceeded 145 V.
• For 200-VAC SERVOPACKs:
The AC power supply voltage exceeded 290 V.
• For 400-VAC SERVOPACKs:
The AC power supply voltage exceeded 580 V.
• For 200-VAC SERVOPACKs: with DC power supply input:
The DC power supply voltage exceeded 410 V.
• For 400-VAC SERVOPACKs:
The DC power supply voltage exceeded 820 V.
The power supply is unstable, or was influenced by a lightning surge.
Voltage for AC power supply was too high during acceleration or deceleration.
The external regenerative resistance is too high for the actual operating conditions.
The mass ratio exceeded the allowable value.
A SERVOPACK fault occurred.
Measure the power supply voltage.
Check the operating conditions and the regenerative resistance.
Confirm that the mass ratio is within the allowable range.
−
Improve the power supply conditions, e.g., by installing a surge absorber. Then, turn the SERVO-
PACK power supply OFF and ON again. If the alarm still occurs, the
SERVOPACK may be faulty.
Replace the SERVOPACK.
Check the power supply voltage and the speed and force during operation.
Set AC power supply voltage within the specified range.
Select a regenerative resistance value appropriate for the operating conditions and load.
Increase the deceleration time, or reduce the load.
Turn the SERVOPACK’s control power supply OFF and ON again while the main circuit power supply is OFF. If the alarm still occurs, the
SERVOPACK may be faulty.
Replace the SERVOPACK.
• For 100-VAC SERVOPACKs:
The AC power supply voltage is 49 V or less.
• For 200-VAC SERVOPACKs:
The AC power supply voltage is 120 V or less.
• For 400-VAC SERVOPACKs:
The AC power supply voltage is 240 V or less.
The power supply voltage dropped during operation.
Measure the power supply voltage.
Increase the power supply capacity.
Occurrence of instantaneous power interruption.
The SERVOPACK fuse is blown out.
A SERVOPACK fault occurred.
Measure the power supply voltage.
−
−
When the instantaneous power cut hold time (Pn509) is set, decrease the setting.
Replace the SERVOPACK, connect a reactor, and run the SERVO-
PACK.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
A.450:
Main-Circuit
Capacitor Overvoltage
A SERVOPACK fault occurred.
− Replace the SERVOPACK.
8
8-11
8-12
8 Troubleshooting
8.1.2 Troubleshooting of Alarms
(cont’d)
Alarm Number:
Alarm Name
Cause Investigative Actions Corrective Actions
A.510:
Overspeed
(The servomotor speed exceeds the maximum.)
A.511:
Overspeed of Encoder
Output Pulse Rate
A.520:
Vibration Alarm
A.521:
Autotuning Alarm
(Vibration was detected while executing the oneparameter tuning,
EasyFFT, or tuning-less function.)
A.550:
Maximum Speed
Setting Error
A.710:
Overload
(High Load)
A.720:
Overload
(Low Load)
The order of phases U, V, and W in the servomotor wiring is incorrect.
A reference value exceeding the overspeed detection level was input.
The servomotor vibrated considerably while performing tuningless function.
The servomotor vibrated considerably during one-parameter tuning or EasyFFT.
Check the motor wiring.
Check the input value.
Confirm that the servomotor is correctly wired.
Reduce the reference value or adjust the gain.
The motor speed exceeded the maximum.
A SERVOPACK fault occurred.
Check the motor speed waveform.
−
Reduce the speed reference input gain, adjust the servo gain, or reconsider the operating conditions.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
Decrease the setting of the encoder output resolution (Pn281).
The encoder output pulse frequency exceeded the limit.
The encoder output pulse output frequency exceeded the limit because the motor speed was too high.
Check the encoder output pulse setting.
Check the encoder output pulse output setting and motor speed.
Abnormal vibration was detected at the motor speed.
Check for abnormal noise from the servomotor, and check the speed and force waveforms during operation.
The mass ratio (Pn103) value is greater than the actual value or is greatly changed.
Check the mass ratio.
Decrease the motor speed.
Reduce the motor speed or reduce the speed loop gain (Pn100).
Set the mass ratio (Pn103) to an appropriate value.
Check the motor speed waveform.
Check the motor speed waveform.
Reduce the load so that the mass ratio falls within the allowable value, or raise the load level using the tuning-less levels setting
(Fn200) or reduce the rigidity level.
Check the operation procedure of corresponding function and take a corrective action.
The Pn385 setting is greater than the maximum speed.
Check the value of Pn385 and
Un010 (Monitor for allowable motor maximum speed and encoder output resolution).
Set Pn385 to a value equal to or lower than the motor maximum speed.
Incorrect wiring or contact fault of servomotor and linear scale.
Operation beyond the overload protection characteristics.
Check the wiring.
Check the servomotor overload characteristics and executed run command.
Confirm that the servomotor and linear scale are correctly wired.
Reconsider the load conditions and operating conditions. Or, increase the motor capacity.
Excessive load was applied during operation because the servomotor was not driven due to mechanical problems.
The setting of the linear scale pitch (Pn282) is incorrect.
The setting of the motor phase selection (Pn080.1) is incorrect.
Check the executed operation reference and motor speed.
Check the setting of Pn282.
Check the setting of Pn080.1.
Remove the mechanical problems.
Correct the setting of Pn282.
Correct the setting of Pn080.1.
A SERVOPACK fault occurred.
−
The SERVOPACK may be faulty.
Replace the SERVOPACK.
8.1 Alarm Displays
(cont’d)
Alarm Number:
Alarm Name
Cause Investigative Actions Corrective Actions
A.730:
A.731:
Dynamic Brake
Overload
(An excessive power consumption of dynamic brake was detected.)
A.740:
Overload of Surge
Current Limit Resistor
(The main circuit power is turned ON/OFF too frequently.)
A.7A0:
Heat Sink Overheated
(Detected when the heat sink temperature exceeds 100
A.7Ab:
° C.)
Built-in Fan in
SERVOPACK
Stopped
A.820:
Encoder Checksum
Error
(Detected on the linear scale side.)
The servomotor moves because of external force.
The moving energy at a DB stop exceeds the DB resistance capacity.
A SERVOPACK fault occurred.
The inrush current limit resistor operation frequency at the main circuit power supply ON/OFF operation exceeds the allowable range.
Incorrect SERVOPACK installation orientation or/and insufficient space around the
SERVOPACK.
−
A SERVOPACK fault occurred.
The surrounding air temperature is too high.
The overload alarm has been reset by turning OFF the power too many times.
Excessive load or operation beyond the regenerative energy processing capacity.
−
Check the surrounding air temperature using a thermostat.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
Decrease the surrounding air temperature by improving the SERVO-
PACK installation conditions.
Check the alarm history display
(Fn000) to see if the overload alarm was reported.
Check the accumulated load ratio
(Un009) to see the load during operation, and the regenerative load ratio (Un00A) to see the regenerative energy processing capacity.
Change the method for resetting the alarm.
Reconsider the load and operating conditions.
Check the SERVOPACK installation conditions.
Reduce the frequency of turning the main circuit power supply ON/OFF.
Install the SERVOPACK correctly as specified.
A SERVOPACK fault occurred.
The fan inside the SERVOPACK stopped.
A linear scale fault occurred.
−
Check for foreign matter or debris inside the SERVOPACK.
−
The SERVOPACK may be faulty.
Replace the SERVOPACK.
Remove foreign matter or debris from the SERVOPACK. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
The linear scale may be faulty.
Replace the linear scale.
A SERVOPACK fault occurred.
Check the operation status.
Check the power consumed by DB resistance (Un00B) to see how many times the DB has been used.
−
−
Take measures to ensure the servomotor will not move because of external force.
Reconsider the following:
• Reduce the motor reference speed.
• Reduce the mass ratio.
• Reduce the number of times of the DB stop operation.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
8
8-13
8-14
8 Troubleshooting
8.1.2 Troubleshooting of Alarms
Alarm Number:
Alarm Name
A.840:
Encoder Data Error
(Detected on the linear scale side.)
A.850:
Encoder Overspeed
(Detected when the control power supply was turned ON.)
(Detected on the linear scale side.)
A.860:
Encoder Overheated
(Only when an absolute linear scale is connected.)
(Detected on the linear scale side.)
Cause Investigative Actions
(cont’d)
Corrective Actions
A linear scale malfunctioned.
Misreading of the linear scale occurred.
The speed of the linear scale exceeded the allowable range.
Malfunction of linear scale because of noise interference, etc.
−
−
−
−
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the linear scale may be faulty. Replace the linear scale.
Reinstall the linear scale, so the tolerance is within the allowable range.
Set the motor speed within the range specified by the linear scale manufacturer and restart the control power supply.
Correct the wiring around the linear scale by separating the linear scale connection cable from the servomotor main circuit cable or by checking the grounding and other wiring.
The hall sensor wiring is incorrect.
A hall sensor fault occurred.
The servomotor speed is higher than the specified speed when the control power supply was turned
ON.
A linear scale fault occurred.
A SERVOPACK fault occurred.
The motor load is greater than the rated load.
A linear scale fault occurred.
A SERVOPACK fault occurred.
Check the hall sensor wiring.
−
Check the motor moving speed
(Un000) to confirm the servomotor speed when the power is turned ON.
−
−
The ambient operating temperature around the servomotor is too high.
Measure the ambient operating temperature around the servomotor.
Check the accumulated load ratio
(Un009) to see the load.
−
−
Correct the hall sensor wiring.
Replace the hall sensor.
Set the motor speed within the range specified by the linear scale manufacturer and restart the control power supply.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the linear scale may be faulty. Replace the linear scale.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
Reduce the ambient operating temperature of the servomotor to 40 ° C or less.
Operate the SERVOPACK so that the motor load remains within the specified range.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the linear scale may be faulty. Replace the linear scale.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
8.1 Alarm Displays
(cont’d)
Alarm Number:
Alarm Name
Cause Investigative Actions Corrective Actions
A.861:
Motor Overheated
A.890:
Encoder Scale Error
A.891:
Encoder Module Error
A.b31:
Current Detection
Error 1
A.b32:
Current Detection
Error 2
A.b33:
Current Detection
Error 3
A.b6A:
MECHATROLINK
Communications ASIC
Error 1
A.b6b:
MECHATROLINK
Communications ASIC
Error 2
A.bE0:
Firmware Error
The ambient operating temperature around the servomotor is too high.
The motor load is greater than the rated load.
A serial converter unit fault occurred.
A SERVOPACK fault occurred.
A linear scale fault occurred.
A linear scale fault occurred.
The current detection circuit for phase U is faulty.
The current detection circuit for phase V is faulty.
The detection circuit for the current is faulty.
Measure the ambient operating temperature around the servomotor.
Check the accumulated load ratio
(Un009) to see the load.
−
−
−
−
−
−
−
Reduce the ambient operating temperature of the servomotor to 40° or less.
Operate the SERVOPACK so that the motor load remains within the specified range.
Turn the power supply OFF and then ON again. If the alarm still occurs, the serial converter unit may be faulty. Replace the serial converter unit.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
The linear scale may be faulty.
Replace the linear scale.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the linear scale may be faulty. Replace the linear scale cable.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
The servomotor main circuit cable is disconnected.
Check for disconnection of the servomotor main circuit cable.
Correct the servomotor wiring.
SERVOPACK
MECHATROLINK communication section fault.
MECHATROLINK data reception error occurred due to noise interference.
SERVOPACK
MECHATROLINK communication section fault.
A SERVOPACK fault occurred.
−
−
−
−
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
Take measures against noise. Check the MECHATROLINK communications cable and FG wiring and take measures such as adding ferrite core on the MECHATROLINK communications cable.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
8
8-15
8 Troubleshooting
8.1.2 Troubleshooting of Alarms
8-16
(cont’d)
Alarm Number:
Alarm Name
Cause Investigative Actions Corrective Actions
A.bF0:
System Alarm 0
A.bF1:
System Alarm 1
A.bF2:
System Alarm 2
A.bF3
System Alarm 3
A.bF4:
A.C10:
Servo Overrun
Detected
(Detected when the servomotor power is
ON.)
:
System Alarm 4
A.C20:
Phase Detection Error
A.C21:
Hall Sensor Error
A SERVOPACK fault occurred.
A SERVOPACK fault occurred.
A SERVOPACK fault occurred.
A SERVOPACK fault occurred.
A SERVOPACK fault occurred.
−
−
−
−
−
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
The order of phases U, V, and W in the servomotor wiring is incorrect.
The setting of the motor phase selection (Pn080.1) is incorrect.
Check the motor wiring.
Check the setting of Pn080.1.
Confirm that the servomotor is correctly wired.
Correct the setting of Pn080.1.
A linear scale fault occurred.
A SERVOPACK fault occurred.
The linear scale signal is weak.
The count-up direction of the linear scale does not match the forward direction of the motor coil assembly.
The hall sensor signal is affected by noise.
The setting of the linear scale pitch (Pn282) is incorrect.
The hall sensor is protruding from the motor magnetic way.
The hall sensor wiring is incorrect.
A hall sensor fault occurred.
−
−
Check the voltage of the linear scale signal.
If the alarm still occurs after turning the power OFF and then ON again, even though the linear scale is correctly wired, the linear scale may be faulty. Replace the linear scale.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
Fine-adjust the installation status of the linear scale head, or replace the linear scale.
Check the setting of Pn080.1
(Motor Phase Selection).
Check the installation directions for the linear scale and motor coil assembly.
Change the setting of Pn080.1
(Motor Phase Selection).
Correctly reinstall the linear scale and motor coil assembly.
−
Check the setting of the linear scale pitch (Pn282).
Check the hall sensor.
Check the hall sensor wiring.
−
Correct the FG wiring and take measures against noise for the hall sensor wiring.
Check the specifications of the linear scale and correct the value of
Pn282.
Correctly reinstall the motor coil assembly or motor magnetic way.
Correct the hall sensor wiring.
Replace the hall sensor.
8.1 Alarm Displays
Alarm Number:
Alarm Name
A.C22:
Phase Information
Disagreement
A.C50:
Polarity Detection
Error
A.C51:
Overtravel
Detection at Polarity
Detection
A.C52:
Polarity Detection
Uncompleted
Cause Investigative Actions
(cont’d)
Corrective Actions
The SERVOPACK phase data does not match that of the linear scale.
− Execute polarity detection (Fn080).
Parameter settings are incorrect.
Noise interference occurred on the scale signal.
An external force was applied to the motor coil assembly.
The linear scale resolution is too low.
An overtravel signal was detected during polarity detection.
The servomotor has been turned
ON under the following circumstances.
• An absolute linear scale is being used.
• The polarity detection selection for the absolute linear scale was set to not execute.
(Pn587.0 = 0)
• Polarity was not yet detected.
−
Check the linear scale specifications and feedback signal status.
The settings of the linear scale pitch
(Pn282) and motor phase selection
(Pn080.1) may not match the actual product requirements. Set these parameters to the correct values.
Check the wiring to see if:
• Each FG of the serial converter unit and servomotor is connected to the FG of the SERVOPACK.
• The FG of the SERVOPACK is connected to the FG of the power supply.
• The linear scale connection cables are securely shielded.
Check to see if the detection reference is repeatedly output in one direction.
Take measures to avoid noise interference by correctly connecting FG lines, shielding the linear scale connection cables, etc.
−
Check the linear scale pitch to see if it is within 100 μ m.
Check the position after overtravel.
The polarity cannot be properly detected if the detection reference is
0 (zero), but the speed feedback is not 0 (zero) because of an external force, such as cable tension, applied to the motor coil assembly.
Take measures to reduce the external force so that the speed feedback becomes 0 for a 0 detection reference.
If external force cannot be reduced, increase the value of the changes in the sequence input signal allocation for each signal (Pn481).
If the linear scale pitch is 100 μ m or longer, the SERVOPACK cannot detect the correct speed feedback.
Use a scale pitch with higher accuracy (a pitch within 40 μ m recommended.) Or, increase the value of the polarity detection reference speed (Pn485). However, note that increasing the value of Pn485 will widen the servomotor movement range required for polarity detection.
Perform the wiring for an overtravel signal. Execute polarity detection at a position where an overtravel signal is not detected.
When using an absolute linear scale, set the parameter Pn587.0 to
1 to execute polarity detection.
8
8-17
8-18
8 Troubleshooting
8.1.2 Troubleshooting of Alarms
Alarm Number:
Alarm Name
Cause Investigative Actions
(cont’d)
Corrective Actions
A.C53:
Out of Range for
Polarity Detection
A.C54:
Polarity Detection
Error 2
A.C80:
Absolute Encoder
Clear Error
The moving distance exceeded the set value of Pn48E in the middle of detection.
External force was applied to the servomotor.
A linear scale fault occurred.
A SERVOPACK fault occurred.
−
−
A.C90:
Encoder
Communications Error
Contact fault of connector or incorrect wiring for linear scale connection cables.
Cable disconnection for linear scale connection cables or shortcircuit.
Or, incorrect cable impedance.
Corrosion caused by improper temperature, humidity, or gas, short-circuit caused by intrusion of water drops or cutting oil, or connector contact fault caused by vibration.
Check the connector contact status for linear scale connection cables.
Check the linear scale connection cables.
Check the operating environment.
Malfunction caused by noise interference.
A SERVOPACK fault occurred.
−
−
−
−
Increase the value of the polarity detection range (Pn48E). Or, increase the value of the changes in the sequence input signal allocation for each signal (Pn481).
Increase the value of the polarity detection confirmation force reference (Pn495).
Increase the value of the polarity detection allowable error range
(Pn498). Note that increasing the allowable error will also increase the motor temperature.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the linear scale may be faulty. Replace the linear scale.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
Re-insert the connectors and confirm that the linear scale is correctly wired.
Use the cables with the specified rating.
Improve the operating environmental conditions, and replace the cable.
If the alarm still occurs, replace the
SERVOPACK.
Correct the wiring around the linear scale by separating the linear scale connection cables from the servomotor main circuit cable or by checking the grounding and other wiring.
Connect the servomotor to another
SERVOPACK, and turn ON the control power. If no alarm occurs, the SERVOPACK may be faulty.
Replace the SERVOPACK.
A.C91:
Encoder
Communications
Position Data Error
Noise interference occurred on the I/O signal line because the linear scale connection cables are bent and the sheaths are damaged.
The linear scale connection cables are bundled with a highcurrent line or near a high-current line.
The FG potential varies because of influence from machines on the servomotor side, such as the welder.
Check the linear scale connection cables and connectors.
Check the cable layout for linear scale connection cables.
Check the cable layout for linear scale connection cables.
Confirm that there is no problem with the cable layout.
Confirm that there is no surge voltage on the cables.
Properly ground the machines to separate from the linear scale FG.
8.1 Alarm Displays
Alarm Number:
A.C92:
Encoder
Communications
Timer Error
A.Cb0:
Encoder Echoback
Error
Alarm Name
A.CA0:
Encoder Parameter
Error
Cause
Noise interference occurred on the I/O signal line from the linear scale.
Excessive vibration and shocks were applied to the linear scale.
A linear scale fault occurred.
A SERVOPACK fault occurred.
A linear scale fault occurred.
A SERVOPACK fault occurred.
−
Investigative Actions
Check the operating environment.
−
−
−
−
(cont’d)
Corrective Actions
Take countermeasures against noise for the linear scale wiring.
Reduce the machine vibration or correctly install the linear scale.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the linear scale may be faulty. Replace the linear scale.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the linear scale may be faulty. Replace the linear scale.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
The wiring and contact for linear scale connection cables are incorrect.
Check the wiring.
Noise interference occurred due to incorrect cable specifications of linear scale connection cables.
−
Noise interference occurred because the wiring distance for the linear scale connection cables are too long.
The FG potential varies because of influence from machines on the servomotor side, such as the welder.
Excessive vibration and shocks were applied to the linear scale.
−
Check the cable layout for linear scale connection cables.
Check the operating environment.
A linear scale fault occurred.
A SERVOPACK fault occurred.
−
−
Correct the wiring.
Use tinned annealed copper shielded twisted-pair or screened unshielded twisted-pair cable with a core of at least 0.12 mm
2
.
The wiring distance must be 20 m max.
Properly ground the machines to separate from linear scale FG.
Reduce the machine vibration or correctly install the linear scale.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the linear scale may be faulty. Replace the linear scale.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
8
8-19
8-20
8 Troubleshooting
8.1.2 Troubleshooting of Alarms
Alarm Number:
Alarm Name
Cause Investigative Actions
(cont’d)
Corrective Actions
A.d00:
Position Error
Overflow
(Position error exceeded the value set in the excessive position error alarm level (Pn520).)
The servomotor U, V, and W wirings is faulty.
Check the servomotor main circuit cable connection.
The position reference speed is too high.
The acceleration of the position reference is too high.
Setting of the excessive position error alarm level (Pn520) is low against the operating condition.
Reduce the reference speed, and operate the SERVOPACK.
Reduce the reference acceleration, and operate the SERVOPACK.
Check the alarm level (Pn520) to see if it is set to an appropriate value.
Confirm that there is no contact fault in the motor wiring or linear scale wiring.
Reduce the position reference speed or acceleration of position reference. Or, reconsider the electronic gear ratio.
Reduce the reference acceleration of the position reference using a
MECHATROLINK command, or smooth the acceleration of the position reference by selecting the position reference filter (ACCFIL) using a MECHATROLINK command.
Set the Pn520 to proper value.
A SERVOPACK fault occurred.
−
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
A.d01:
Position Error
Overflow Alarm at
Servo ON
A.d02:
Position Error
Overflow Alarm by
Speed Limit at Servo
ON
This alarm occurs if the servomotor power is turned ON when the position error is greater than the set value of Pn526 while the servomotor power is OFF.
When the position errors remain in the error counter, Pn584 limits the speed if the servomotor power is ON. If Pn584 limits the speed in such a state, this alarm occurs when position references are input and the number of position errors exceeds the value set for the excessive position error alarm level (Pn520).
Check the position error amount
(Un008) while the servomotor power is OFF.
−
Correct the excessive position error alarm level at servo ON (Pn526).
Correct the excessive position error alarm level (Pn520).
Or, adjust the speed limit level at servo ON (Pn584).
A.d30:
Position Data
Overflow
The position data exceeded
±1879048192.
Check the input reference pulse counter (Un00C).
Reconsider the operating specifications.
A.E02:
MECHATROLINK
Internal
Synchronization
Error 1
MECHATROLINK transmission cycle fluctuated.
−
A SERVOPACK fault occurred.
−
Remove the cause of transmission cycle fluctuation at host controller.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
A.E40:
MECHATROLINK
Transmission Cycle
Setting Error
Setting of MECHATROLINK transmission cycle is out of specifications range.
Check the MECHATROLINK transmission cycle setting.
Set the transmission cycle to the proper value.
A.E50:
MECHATROLINK
Synchronization Error
WDT data of host controller was not updated correctly.
Check the WDT data updating for the host controller.
A SERVOPACK fault occurred.
−
Update the WDT data at the host controller correctly.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
8.1 Alarm Displays
(cont’d)
Alarm Number:
Alarm Name
Cause Investigative Actions Corrective Actions
A.E51:
MECHATROLINK
Synchronization
Failed
A.E60:
MECHATROLINK
Communications error
(Reception error)
A.E61:
MECHATROLINK
Transmission Cycle
Error
(Synchronization interval error)
A.E71:
Safety Option Module
Detection Failure
WDT data of host controller was not updated correctly at the synchronization communications start, and synchronization communications could not start.
Check the WDT data updating for the host controller.
Update the WDT data at the host controller correctly.
A SERVOPACK fault occurred.
MECHATROLINK wiring is incorrect.
MECHATROLINK data reception error occurred due to noise interference.
A SERVOPACK fault occurred.
MECHATROLINK transmission cycle fluctuated.
A SERVOPACK fault occurred.
The connection between the
SERVOPACK and the safety option module is faulty.
The safety option module was disconnected.
−
Check the MECHATROLINK wirings.
−
−
Check the MECHATROLINK transmission cycle setting.
−
–
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
Correct the MECHATROLINK wiring.
Connect the terminator correctly.
Take measures against noise. Check the MECHATROLINK communications cable and FG wiring and take measures such as adding ferrite core on the MECHATROLINK communications cable.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
Remove the cause of transmission cycle fluctuation at host controller.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
Check the connection between the
SERVOPACK and the safety option module.
Correctly connect the safety option module.
Execute Fn014 (Resetting configuration error in option module) from the digital operator or SigmaWin+, and then turn the power supply OFF and ON again.
A safety option module fault occurred.
– Replace the safety option module.
Replace the SERVOPACK.
A.E74:
Unsupported Safety
Option Module
A.E75:
Unsupported
Feedback Option
Module
A.EA2:
DRV Alarm 2
(SERVOPACK WDT error)
A SERVOPACK fault occurred.
–
A safety option module fault occurred.
A unsupported safety option module was connected.
A feedback option module fault occurred.
−
Refer to the catalog of the connected safety option module.
−
A unsupported feedback option module was connected.
MECHATROLINK transmission cycle fluctuated.
Refer to the catalog of the connected feedback option module or the manual of the SERVOPACK.
Check the MECHATROLINK transmission cycle setting.
A SERVOPACK fault occurred.
−
Replace the safety option module.
Connect a compatible safety option module.
Replace the feedback option module.
Connect a compatible feedback option module.
Remove the cause of transmission cycle fluctuation at host controller.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
8
8-21
8-22
8 Troubleshooting
8.1.2 Troubleshooting of Alarms
Alarm Number:
Alarm Name
Cause Investigative Actions
(cont’d)
Corrective Actions
A.Eb1:
Safety Function Signal
Input Timing Error
The lag between activations of the input signals /HWBB1 and
/HWBB2 for the HWBB function is ten second or more.
Measure the time lag between the /
HWBB1 and
/HWBB2 signals.
A.Ed1:
Command Execution
Timeout
A timeout error occurred when using an MECHATROLINK command.
Check the motor status when the command is executed.
Check the status of the linear scale after an output is made to execute the command.
The three-phase power supply wiring is incorrect.
The three-phase power supply is unbalanced.
A single-phase power is input without setting Pn00B.2 (power supply method for three-phase
SERVOPACK) to 1 (single-phase power supply).
Check the power supply wiring.
A.F10:
Main Circuit Cable
Open Phase
(A low voltage continued for one second or longer in either phase R,
S, or T when the main circuit power supply was
ON.)
(Detected when the main circuit power supply is turned ON.)
A SERVOPACK fault occurred.
−
Measure the voltage at each phase of the three-phase power supply.
Check the power supply and the parameter setting.
The output signal circuits or devices for /HWBB1 and
/HWBB2 or the SERVOPACK input signal circuits may be faulty.
Alternatively, the input signal cables may be disconnected. Check if any of these items are faulty or have been disconnected.
Execute the SV_ON or SENS_ON command only when the motor is not running.
Execute the SENS_ON command only when a linear scale is connected.
Confirm that the power supply is correctly wired.
Balance the power supply by changing phases.
Match the parameter setting to the power supply.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
A.F50:
Servomotor Main
Circuit Cable
Disconnection
(The servomotor did not operate or power was not supplied to the servomotor even though the SV_ON (Servo ON) command was input when the servomotor was ready to receive it.)
A SERVOPACK fault occurred.
−
The wiring is not correct or there is a faulty contact in the motor wiring.
Check the wiring.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
Make sure that the servomotor is correctly wired.
8.1 Alarm Displays
(cont’d)
Alarm Number:
Alarm Name
FL-1
*3
:
System Alarm
FL-2
*3
:
System Alarm
Cause
SERVOPACK failure −
Investigative Actions Corrective Actions
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
CPF00:
Digital Operator
Transmission Error 1
The contact between the digital operator and the SERVOPACK is faulty.
Malfunction caused by noise interference.
A digital operator fault occurred.
Check the connector contact.
−
−
Insert securely the connector or replace the cable.
Keep the digital operator or the cable away from noise sources.
Disconnect the digital operator and then re-connect it. If the alarm still occurs, the digital operator may be faulty. Replace the digital operator.
CPF01:
Digital Operator
Transmission Error 2
A SERVOPACK fault occurred.
−
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
∗3.
These alarms are not stored in the alarm history and are displayed only in the panel display.
8
8-23
8-24
8 Troubleshooting
8.2.1 List of Warnings
8.2
Warning Displays
The following sections describe troubleshooting in response to warning displays.
The warning name and warning meaning output are listed in order of the warning numbers in 8.2.1 List of
Warnings .
The causes of warnings and troubleshooting methods are provided in 8.2.2 Troubleshooting of Warnings .
8.2.1
List of Warnings
This section provides list of warnings.
Warning
Number
Warning Name Meaning
A.900
A.901
A.910
A.911
A.920
A.921
*1
*1
*1
*1
*1
*1
Position Error Overflow
Position Error Overflow
Alarm at Servo ON
Overload
Vibration
Regenerative Overload
Dynamic Brake Overload
Position error exceeded the parameter setting
(Pn520 × Pn51E/100).
When the servomotor power is ON, the position error exceeded the parameter setting (Pn526 × Pn528/100).
This warning occurs before the overload alarms (A.710 or A.720) occur. If the warning is ignored and operation continues, an overload alarm may occur.
Abnormal vibration at the motor speed was detected. The detection level is the same as A.520. Set whether to output an alarm or warning by the vibration detection switch (Pn310).
This warning occurs before the regenerative overload alarm (A.320) occurs.
If the warning is ignored and operation continues, a regenerative overload alarm may occur.
This warning occurs before dynamic brake overload alarm (A.731) occurs. If the warning is ignored and operation continues, a dynamic brake overload alarm may occur.
A.94A
A.94B
A.94C
A.94D
A.94E
A.95A
A.95B
A.95D
A.95E
A.95F
A.960
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
Data Setting Warning 1
(Parameter Number Error)
Data Setting Warning 2
(Out of Range)
Data Setting Warning 3
(Calculation Error)
Data Setting Warning 4
(Parameter Size)
Data Setting Warning 5
(Latch Mode Error)
Command Warning 1
(Unsatisfying Command)
Command Warning 2
(Non-supported
Command)
Command Warning 4
(Command Interference)
Command Warning 5
(Subcommand Disable)
Command Warning 6
(Undefined Command)
MECHATROLINK
Communications Warning
Incorrect command parameter number was set.
Command input data is out of range.
Calculation error was detected.
Data size does not match.
Latch mode error is detected.
Command was sent although the conditions for sending a command were not satisfied.
Unsupported command was sent.
Command, especially latch command, interferes.
Subcommand and main command interfere.
Undefined command was sent.
Communications error occurred during MECHATROLINK communications.
A.971
*3
A.9A0
*1
Undervoltage
Overtravel
This warning occurs before undervoltage alarm (A.410) occurs. If the warning is ignored and operation continues, an undervoltage alarm may occur.
Overtravel is detected while the servomotor power is ON.
∗1.
Use Pn008.2 to activate or not the warning detection.
∗2.
Use Pn800.1 to activate or not the warning detection.
∗3.
Use Pn008.1 to activate or not the warning detection.
8.2 Warning Displays
8.2.2
Troubleshooting of Warnings
Refer to the following table to identity the cause of a warning and the action to be taken. Contact your
Yaskawa representative if the problem cannot be solved by the described corrective action.
Warning Number: Warning
Name
Cause Investigative Actions Corrective Actions
A.900:
Position Error
Overflow
The servomotor U, V, and W wirings is faulty.
The SERVOPACK gain is too low.
The acceleration of the position reference is too high.
Check the servomotor main circuit cable connection.
Check the SERVOPACK gain.
Reduce the reference acceleration, and operate the SERVOPACK.
Confirm that there is no contact fault in the motor wiring or linear scale wiring.
Increase the servo gain by using the function such as advanced autotuning.
Reduce the reference acceleration of the position reference using a
MECHATROLINK command, or smooth the acceleration of the position reference by selecting the position reference filter (ACCFIL) using a MECHATROLINK command.
Setting of the excessive position error alarm level (Pn520) is low against the operating condition.
Check the alarm level (Pn520) to see if it is set to an appropriate value.
Set the Pn520 to proper value.
A SERVOPACK fault occurred.
−
Turn the power supply to the SER-
VOPACK OFF and ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVO-
PACK.
A.901:
Position Error
Overflow Alarm at Servo ON
When the servomotor power is ON, the position error exceeded the parameter setting
(Pn526 × Pn528/100).
−
Set an appropriate value for the excessive position error warning level at servo ON (Pn528).
Incorrect wiring or contact fault of servomotor and linear scale.
Check the wiring.
A SERVOPACK fault occurred.
−
Confirm that the servomotor and linear scale are correctly wired.
A.910:
Overload
(Warning before the overload alarm
(A.710 or A.720).)
Operation beyond the overload protection characteristics.
Excessive load was applied during operation because the servomotor was not driven due to mechanical problems.
Check the motor overload characteristics and executed run command.
Check the executed operation reference and motor speed.
Reconsider the load conditions and operating conditions. Or, increase the motor capacity.
Remove the mechanical problems.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
A.911:
Vibration
Abnormal vibration was detected at the motor speed.
The mass ratio
(Pn103) value is greater than the actual value or is greatly changed.
Check for abnormal noise from the servomotor, and check the speed and force waveforms during operation.
Check the mass ratio.
Reduce the motor speed or reduce the servo gain by using the function such as one-parameter tuning.
Set the mass ratio (Pn103) to an appropriate value.
8
8-25
8-26
8 Troubleshooting
8.2.2 Troubleshooting of Warnings
A.94A
Data Setting
Warning 1
(Parameter Number Error)
A.94B
Data Setting
Warning 2
(Out of Range)
A.94C
Data Setting
Warning 3
(Calculation Error)
A.94D
Data Setting
Warning 4
(Parameter Size )
A.94E
Data Setting
Warning 5
(Latch mode error)
A.95A
Command
Warning 1
(Unsatisfying
Command)
(cont’d)
Warning Number: Warning
Name
Cause Investigative Actions Corrective Actions
A.920:
Regenerative
Overload
(Warning before the alarm A.320 occurs)
A.921:
Dynamic Brake
Overload
(Warning before the alarm A.731 occurs)
The power supply voltage exceeds the specified limit.
Insufficient external regenerative resistance, regenerative resistor capacity, or
SERVOPACK capacity.
Or, regenerative power has been continuously flowing back.
Regenerative power continuously flowed back because negative load was continuously applied.
The servomotor moves because of external force.
Measure the power supply voltage.
Check the operating condition or the capacity using the capacity selection Software SigmaJunmaSize+, etc.
Check the load to the servomotor during operation.
Check the operation status.
Set the power supply voltage within the specified range.
Change the regenerative resistance, regenerative resistor capacity, or
SERVOPACK capacity. Reconsider the operating conditions using the capacity selection software Sigma-
JunmaSize+, etc.
Reconsider the system including servo drives, machine, and operating conditions.
Take measures to ensure the servomotor will not move because of external force.
The moving energy at a DB stop exceeds the
DB resistance capacity.
Check the power consumed by DB resistance (Un00B) to see how many times the DB has been used.
Reconsider the following:
• Reduce the motor reference speed.
• Reduce the mass ratio.
• Reduce the number of times of the
DB stop operation.
A SERVOPACK fault occurred.
−
The SERVOPACK may be faulty.
Replace the SERVOPACK.
Disabled parameter number was used.
Attempted to send values outside the range to the command data.
Calculation result of set value is incorrect.
Parameter size set in command is incorrect.
Latch mode error is detected.
Command sending condition is not satisfied.
Refer to 8.3 Monitoring Communication Data on Occurrence of an
Alarm or Warning to determine which command was the cause of the warning.
Refer to 8.3 Monitoring Communication Data on Occurrence of an
Alarm or Warning to determine which command was the cause of the warning.
Refer to 8.3 Monitoring Communication Data on Occurrence of an
Alarm or Warning to determine which command was the cause of the warning.
Refer to 8.3 Monitoring Communication Data on Occurrence of an
Alarm or Warning to determine which command was the cause of the warning.
Refer to 8.3 Monitoring Communication Data on Occurrence of an
Alarm or Warning to determine which command was the cause of the warning.
Refer to 8.3 Monitoring Communication Data on Occurrence of an
Alarm or Warning to determine which command was the cause of the warning.
Use the correct parameter number.
Set the value of the parameter within the allowable range.
Set the value of the parameter within the allowable range.
Use the correct parameter size.
Change the setting value of Pn850 or the LT_MOD data for the LTMOD-
_ON command sent by the host controller to the proper value.
Send a command after command sending condition is satisfied.
8.2 Warning Displays
(cont’d)
Warning Number: Warning
Name
A.95B
Command
Warning 2
(Non-supported
Command)
A.95D
Command
Warning 4
(Command Interference)
A.95E
Command
Warning 5
(Subcommand
Disable)
A.95F
Command
Warning 6
(Undefined Command)
Cause Investigative Actions
SERVOPACK received unsupported command.
Command sending condition for latchrelated commands is not satisfied.
Subcommand sending condition is not satisfied.
Undefined command was sent.
Refer to 8.3 Monitoring Communication Data on Occurrence of an
Alarm or Warning to determine which command was the cause of the warning.
Refer to 8.3 Monitoring Communication Data on Occurrence of an
Alarm or Warning to determine which command was the cause of the warning.
Refer to 8.3 Monitoring Communication Data on Occurrence of an
Alarm or Warning to determine which command was the cause of the warning.
Refer to 8.3 Monitoring Communication Data on Occurrence of an
Alarm or Warning to determine which command was the cause of the warning.
Corrective Actions
Do not sent an unsupported command.
Send a command after command sending condition is satisfied.
Send a command after command sending condition is satisfied.
Do not use an undefined command.
A.960
MECHATROLINK
Communications
Warning
MECHATROLINK wiring is incorrect.
MECHATROLINK data reception error occurred due to noise interference.
Confirm the wiring.
Confirm the installation conditions.
Correct the MECHATROLINK wiring.
Or, connect a terminal to the terminal station.
Take measures against noise. Check the MECHATROLINK communications cable and FG wiring and take measures such as adding ferrite core on the MECHATROLINK communications cable.
A SERVOPACK fault occurred.
–
A fault occurred in the SERVO-
PACK. Replace the SERVOPACK.
8
8-27
8-28
8 Troubleshooting
8.2.2 Troubleshooting of Warnings
(cont’d)
Warning Number: Warning
Name
A.971:
Undervoltage
Cause Investigative Actions Corrective Actions
• For 100 VAC
SERVOPACKs:
The AC power supply voltage is 60 V or less.
• For 200-VAC
SERVOPACKs:
The AC power supply voltage is 140 V or less.
• For 400-VAC
SERVOPACKs:
The AC power supply voltage is 280 V or less.
The power supply voltage dropped during operation.
Occurrence of instantaneous power interruption.
Measure the power supply voltage.
Measure the power supply voltage.
Set the power supply voltage within the specified range.
Measure the power supply voltage.
Increase the power supply capacity.
When the instantaneous power cut hold time (Pn509) is set, decrease the setting.
The SERVOPACK fuse is blown out.
−
Replace the SERVOPACK and connect a reactor to the SERVOPACK.
A SERVOPACK fault occurred.
−
A.9A0:
Overtravel
(Overtravel status is detected.)
When the servomotor power is ON, overtravel status is detected.
Check the input signal monitor
(Un005) to check the status of the overtravel signals.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
Refer to 8.4 Troubleshooting Malfunction Based on Operation and
Conditions of the Servomotor . Even if overtravel signals were not shown by the input signal monitor (Un005), momentary overtravel may have been detected. Take the following precautions.
• Do not specify movements that would cause overtravel from the host controller.
• Check the wiring of the overtravel signals.
• Take countermeasures for noise.
8.3 Monitoring Communication Data on Occurrence of an Alarm or Warning
8.3
Monitoring Communication Data on Occurrence of an Alarm or
Warning
The command data received on occurrence of an alarm or warning, such as a data setting warning (A.94
) or a command warning (A.95
) can be monitored using the following parameters. The following is an example of the data when an alarm/warning has occurred in the normal state.
Command Data Monitor at Alarm/Warning Occurrence: Pn890 to Pn89E
Response Data Monitor at Alarm/Warning Occurrence: Pn8A0 to Pn8AE
Command
Byte Order
1
2
3
4
5 to 8
9 to 12
13 to 16
17 to 20
21 to 24
25 to 28
29 to 32
Command Data Storage at
Alarm/Warning Occurrence
CMD
Pn890.1 to 0
RSP
Pn8A0.1 to 0
Pn890.3 to 2
Pn890.5 to 4
Pn890.7 to 6
Pn892
Pn8A0.3 to 2
Pn8A0.5 to 4
Pn8A0.7 to 6
Pn8A2
Pn894
Pn896
Pn898
Pn89A
Pn89C
Pn89E
Pn8A4
Pn8A6
Pn8A8
Pn8AA
Pn8AC
Pn8AE
Example: Pn8A0 = 87 65 43 21
Note 1. Data is stored in little endian byte order and displayed in the hexadecimal format.
2. For details on commands, refer to the Σ -V Series/DC Power Input Σ -V Series/ Σ -V Series for Large-Capacity
Models User’s Manual MECHATROLINK-II Commands (Manual No.: SIEP S800000 54) .
8
8-29
8-30
8 Troubleshooting
8.4
Troubleshooting Malfunction Based on Operation and
Conditions of the Servomotor
Troubleshooting for the malfunctions based on the operation and conditions of the servomotor is provided in this section.
Problem Probable Cause
The control power supply is not
ON.
The main circuit power supply is not ON.
Investigative Actions
Check voltage between control power terminals.
Check the voltage between main circuit power terminals.
Corrective Actions
Turn OFF the servo system.
Correct the wiring.
Turn OFF the servo system.
Correct the wiring so that the main circuit power supply turns
ON.
Wiring of I/O signal connector
CN1 is faulty or disconnected.
Turn OFF the servo system.
Check if the connector CN1 is properly inserted and connected.
Correct the connector CN1 connection.
Wiring for servomotor main circuit cable or linear scale connection cables is disconnected.
Check the wiring.
Turn OFF the servo system.
Correct the wiring.
Overloaded
Linear scale type differs from parameter setting (Pn002.2).
Settings for the input signal selections (Pn50A, Pn50B and
Pn511) is incorrect.
Run under no load and check the load status.
Check the settings for parameter Pn002.2.
Check the settings for parameters Pn50A, Pn50B and Pn511.
Turn OFF the servo system.
Reduce load or replace with larger capacity servomotor.
Set parameter Pn002.2 to the linear scale type being used.
Correct the settings for parameter Pn50A, Pn50B and Pn511.
Servomotor Does
Not Start
SV_ON command is not sent.
SENS_ON command is not sent.
The forward run prohibited (P-
OT) and reverse run prohibited
(N-OT) input signals are turned
OFF.
Check the command sent from the host controller.
Check the command sent from the host controller.
Check P-OT or N-OT input signal.
Send the SV_ON command.
Send the command in the correct SERVOPACK sequence.
Turn P-OT or N-OT input signal ON.
The safety input signal
(/HWBB1 or /HWBB2) remains OFF.
A SERVOPACK fault occurred.
The polarity detection is not executed.
Check the /HWBB1 and /
HWBB2 input signal.
Check the SV_ON command.
Set the /HWBB1 and /HWBB2 input signal to ON.
When not using the safety function, mount the safety function’s jumper connector
(provided as an accessory) on the CN8.
−
Turn OFF the servo system.
Replace the SERVOPACK.
Check the parameter Pn080.0.
Correct the setting of Pn080.0.
• For an incremental linear scale, input the Servo ON
(SV_ON) command from the host controller.
• For an absolute linear scale, execute Fn080.
8.4 Troubleshooting Malfunction Based on Operation and Conditions of the Servomotor
Problem Probable Cause Investigative Actions
(cont’d)
Corrective Actions
Correct the wiring.
Serial converter unit wiring is incorrect.
Turn OFF the servo system.
Check the wiring.
Correct the wiring.
Correct the wiring.
Servomotor
Moves Instantaneously, and then
Stops
Servomotor
Speed Unstable
Servomotor
Moves Without
Reference Input
Dynamic Brake
Does Not Operate
Abnormal Noise from Servomotor
Linear scale pitch (Pn282) is incorrect.
Linear scale counting up direction and servomotor coil assembly forward direction do not agree.
Polarity detection is not performed correctly.
Wiring connection to servomotor is defective.
A SERVOPACK fault occurred.
Linear scale counting up direction and servomotor coil assembly forward direction do not agree.
Polarity detection is not performed correctly.
Improper Pn001.0 setting
DB resistor disconnected
DB drive circuit fault
The servomotor largely vibrated during execution of tuning-less function.
Check the setting of Pn282.
Correct the setting of Pn282.
Check the directions.
−
Check the directions.
Change the setting of Pn080.1
(Motor Phase Selection).
Match the linear scale direction and coil assembly direction.
Check if the value of Un004
(electrical angle 2 from polarity origin) at an arbitrary position is between ± 10 degrees.
Turn OFF the servo system.
Check connections of power line (phases U, V, and W) and serial converter unit connectors.
Correct the settings for the polarity detection related parameter.
Tighten any loose terminals or connectors and correct the wiring.
Turn OFF the servo system.
Replace the SERVOPACK.
Change the setting of Pn080.1
(Motor Phase Selection).
Match the linear scale direction and servomotor direction.
Check if the value of Un004
(electrical angle 2 from polarity origin) at an arbitrary position is between ± 10 degrees.
Check the setting for parameter Pn001.0.
Check if excessive mass, motor overspeed, or DB frequently activated occurred.
−
Check the motor speed waveform.
Correct the settings for the polarity detection related parameter.
Correct the setting for parameter Pn001.0.
Turn OFF the servo system.
Replace the SERVOPACK, and reduce the load.
Turn OFF the servo system.
There is a defective component in the DB circuit. Replace the
SERVOPACK.
Reduce the load so that the mass ratio becomes within the allowable value, or increase the load level or lower the tuning level for the tuning-less levels setting (Fn200).
Mounting is not secured.
Vibration source at the driven machine.
Noise interference due to incorrect I/O signal cable specifications.
Noise interference due to length of I/O signal cable.
Turn OFF the servo system.
Check if there are any loose mounting screws.
Turn OFF the servo system.
Check for any foreign matter, damage, or deformations on the machinery's movable parts.
Turn OFF the servo system.
The I/O signal cable must be tinned annealed copper shielded twisted-pair or screened unshielded twistedpair cable with a core of 0.12 mm
2
min.
Turn OFF the servo system.
Check the length of the I/O signal cable.
Tighten the mounting screws.
Contact the machine manufacturer.
Use the specified I/O signal cable.
The I/O signal cables must be no longer than 3 m.
8
8-31
8-32
8 Troubleshooting
Problem
Abnormal Noise from Servomotor
(cont’d)
Servomotor Vibrates at Frequency of Approx.
200 to 400 Hz.
Probable Cause
Noise interference due to incorrect cable specifications of linear scale connection cables.
Investigative Actions
Turn OFF the servo system.
The linear scale connection cables must be tinned annealed copper shielded twisted-pair or screened unshielded twistedpair cable with a core of 0.12 mm
2
min.
(cont’d)
Corrective Actions
Use the specified linear scale connection cables.
Noise interference due to length of linear scale connection cables.
Turn OFF the servo system.
Check the length of the linear scale connection cables.
The length of each cable must be equal to or shorter than the maximum wiring length listed here.
• Connection cables for serial converter unit: 20 m
• Connection cables for linear scale: 15 m
• Connection cables for hall sensor: 15 m
Noise interference due to damaged linear scale connection cables.
Excessive noise to the linear scale connection cables.
Turn OFF the servo system.
Check if the linear scale connection cables are bent and the sheaths are damaged.
Turn OFF the servo system.
Check if the linear scale connection cables are bundled with a high-current line or near a high-current line.
Replace the linear scale connection cables and correct the cable layout.
Correct the cable layout so that no surge is applied.
The FG potential varies because of influence from machines on the servomotor side, such as the welder.
Turn OFF the servo system.
Check if the machines are correctly grounded.
Properly ground the machines to separate from the linear scale
FG.
SERVOPACK pulse counting error due to noise interference
Excessive vibration and shock to the linear scale
Check if there is noise interference on the I/O signal line from the linear scale.
Turn OFF the servo system.
Check if vibration from the machine occurred or linear scale installation is incorrect
(mounting surface accuracy and fixing method).
Turn OFF the servo system.
Take measures against noise in the linear scale wiring.
Reduce vibration from the machine, or secure the linear scale installation.
Serial converter unit fault
A linear scale fault occurred.
Unbalanced servo gains
Speed loop gain value (Pn100) too high.
Position loop gain value
(Pn102) too high.
Incorrect speed loop integral time constant (Pn101)
Incorrect mass ratio (Pn103)
−
−
Turn OFF the servo system.
Replace the serial converter unit.
Turn OFF the servo system.
Replace the linear scale.
Execute the advanced autotuning.
Check to see if the servo gains have been correctly adjusted.
Check the speed loop gain
(Pn100).
Factory setting: Kv = 40.0 Hz
Reduce the speed loop gain
(Pn100).
Check the position loop gain
(Pn102).
Factory setting: Kp = 40.0/s
Check the speed loop integral time constant (Pn101).
Factory setting: Ti = 20.0 ms
Reduce the position loop gain
(Pn102).
Correct the speed loop integral time constant (Pn101).
Check the mass ratio (Pn103).
Correct the mass ratio (Pn103).
8.4 Troubleshooting Malfunction Based on Operation and Conditions of the Servomotor
Problem Probable Cause
Unbalanced servo gains
Speed loop gain value (Pn100) too high
High Motor Speed
Overshoot on
Starting and Stopping
Position loop gain value
(Pn102) too high
Incorrect speed loop integral time constant (Pn101)
Incorrect mass ratio data
(Pn103)
The force reference is saturated.
Investigative Actions
Check to see if the servo gains have been correctly adjusted.
Check the speed loop gain
(Pn100).
Factory setting: Kv = 40.0 Hz
Check the position loop gain
(Pn102).
Factory setting: Kp = 40.0/s
Check the speed loop integral time constant (Pn101).
Factory setting: Ti = 20.0 ms
Check the mass ratio (Pn103).
The force limit (Pn483, Pn484) is set to the initial value.
Noise interference due to incorrect cable specifications of linear scale connection cables.
Check the force reference waveform.
Initial value of force limit:
Pn483 = 30%
Pn484 = 30%
Turn OFF the servo system.
The linear scale connection cables must be tinned annealed copper shielded twisted-pair or screened unshielded twistedpair cable with a core of 0.12 mm
2
min.
ing.
(cont’d)
Corrective Actions
Execute the advanced autotun-
Reduce the speed loop gain
(Pn100).
Reduce the position loop gain
(Pn102).
Correct the speed loop integral time constant (Pn101).
Correct the mass ratio (Pn103).
Use the mode switch function.
Set a appropriate value for
Pn483 and Pn484 (Force
Limit).
Use the specified linear scale connection cables.
Noise interference due to length of linear scale connection cables.
Turn OFF the servo system.
Check the length of the linear scale connection cables.
The length of each cable must be equal to or shorter than the maximum wiring length listed here.
• Connection cables for serial converter unit: 20 m
• Connection cables for linear scale: 15 m
• Connection cables for hall sensor: 15 m
Absolute Linear
Scale Position Difference Error (The position saved in the host controller when the power was turned OFF is different from the position when the power was next turned ON.)
Noise interference due to damaged linear scale connection cables.
Excessive noise to the linear scale connection cables.
FG potential varies because of influence of machines such as welders at the servomotor.
SERVOPACK pulse counting error due to noise interference
Excessive vibration and shock to the linear scale
Turn OFF the servo system.
Check if the linear scale connection cables are bent and the sheaths are damaged.
Turn OFF the servo system.
Check if the linear scale connection cables are bundled with a high-current line or near a high-current line.
Turn OFF the servo system.
Check if the machines are correctly grounded.
Turn OFF the servo system.
Check if there is noise interference on the I/O signal line from the serial converter unit.
Turn OFF the servo system.
Check to see if the machine is vibrating.
Also, check the installation conditions of the linear scale
(flange face accuracy and anchoring condition).
Replace the linear scale connection cables and correct the cable layout.
Correct the cable layout so that no surge is applied.
Ground machines correctly, and prevent diversion to the FG on the linear scale side.
Take measures against noise in the serial converter unit wiring.
Reduce vibration from the machine, or secure the linear scale installation.
8
8-33
8-34
8 Troubleshooting
Problem
Absolute Linear
Scale Position Difference Error (The position saved in the host controller when the power was turned OFF is different from the position when the power was next turned ON.)
(cont’d)
Overtravel (OT)
Improper Stop Position by Overtravel (OT) Signal
Probable Cause
A linear scale fault occurred.
−
A SERVOPACK fault occurred.
−
Investigative Actions
Host controller serial data reading error
Forward or reverse run prohibited signal is input.
Forward or reverse run prohibited signal malfunctioning.
Incorrect forward or reverse run prohibited signal (P-OT/N-
OT) allocation (parameters
Pn50A.3, Pn50B.0)
Incorrect servomotor stop method selection
Check the error detection section of the host controller.
Check if the host controller is executing data parity checks.
Check noise in the cable between the SERVOPACK and the host controller.
Check the external power supply (+24 V) voltage for the input signal.
Check if the overtravel limit switch operates properly.
Check if the overtravel limit switch is wired correctly.
Check the settings for parameters Pn50A and Pn50B.
Check the fluctuation of the external power supply (+24 V) voltage for the input signal.
Check if the overtravel limit switch operates correctly.
Check if the overtravel limit switch wiring is correct. (check for damaged cables or loose screws.)
Check if the P-OT signal is allocated in Pn50A.3.
Check if the N-OT signal is allocated in Pn50B.0.
Check the settings for parameters Pn001.0 and Pn001.1 when the servomotor power is OFF.
Check the settings for parameters Pn001.0 and Pn001.1 when in force control.
Improper limit switch position and dog length
The overtravel limit switch position is too short for the coasting distance.
−
−
Noise interference due to incorrect linear scale connection cable specifications
Turn OFF the servo system.
The linear scale connection cable must be tinned annealed copper shielded twisted-pair or screened unshielded twistedpair cable with a core of 0.12 mm
2
min.
Position Error
(Without Alarm)
(cont’d)
Corrective Actions
Turn OFF the servo system.
Replace the linear scale.
Turn OFF the servo system.
Replace the SERVOPACK.
Correct the error detection section of the host controller.
Perform a parity check on the serial data.
Implement measures against noise and perform a parity check on the serial data again.
Correct the external power supply (+24 V) voltage.
Correct the overtravel limit switch.
Correct the overtravel limit switch wiring.
Correct the settings for parameters Pn50A and Pn50B.
Stabilize the external power supply (+24 V) voltage.
Correct the overtravel limit switch.
Correct the overtravel limit switch wiring.
If another signal is allocated in
Pn50A.3, allocate P-OT.
If another signal is allocated in
Pn50B.0, allocate N-OT.
Select a servomotor stop method other than "coast to stop."
Select a servomotor stop method other than "coast to stop."
Install the limit switch at the appropriate position.
Install the overtravel limit switch at the appropriate position.
Use the specified linear scale connection cable.
Noise interference due to length of linear scale connection cables.
Turn OFF the servo system.
Check the length of the linear scale connection cables.
The length of each cable must be equal to or shorter than the maximum wiring length listed here.
• Connection cables for serial converter unit: 20 m
• Connection cables for linear scale: 15 m
• Connection cables for hall sensor: 15 m
8.4 Troubleshooting Malfunction Based on Operation and Conditions of the Servomotor
Problem
Position Error
(Without Alarm)
(cont’d)
Servomotor
Overheated
Probable Cause
Noise influence due to damaged linear scale connection cables.
Excessive noise to linear scale connection cables.
The FG potential varies because of influence from machines on the servomotor side such as the welder.
Turn OFF the servo system.
Check if the machines are correctly grounded.
Properly ground the machines linear scale FG.
SERVOPACK pulse count error due to noise
Excessive vibration and shock to the linear scale
Noise interference due to improper I/O signal cable specifications
Noise interference due to length of I/O signal cable
Turn OFF the servo system.
Check if the I/O signal line from the serial converter unit is influenced by noise.
Turn OFF the servo system.
Check if vibration from the machine occurred or linear scale installation is incorrect
(mounting surface accuracy and fixing method).
Turn OFF the servo system.
The I/O signal cable must be tinned annealed copper shielded twisted-pair or screened unshielded twistedpair cable with a core of 0.12 mm
2
min.
Turn OFF the servo system.
Check the I/O signal cable length.
Take measures against noise in the serial converter unit wiring.
Reduce the machine vibration or mount the linear scale securely.
Use input signal cable with the specified specifications.
The I/O signal cables must be no longer than 3 m.
A linear scale fault occurred.
(The pulse count does not change.)
A SERVOPACK fault occurred.
Ambient operating temperature too high
Servomotor surface dirty
Servomotor overloaded
Polarity detection is not performed correctly.
Investigative Actions
Turn OFF the servo system.
Check if the linear scale connection cables are bent and the sheaths are damaged.
Turn OFF the servo system.
Check if the linear scale connection cables are bundled with a high-current line or near a high-current line.
(cont’d)
Corrective Actions
Replace the linear scale connection cables and modify the cable layout.
Change the cable layout so that no surge is applied.
−
−
Measure the servomotor ambient operating temperature.
Turn OFF the servo system.
Visually check the surface.
Check the load status with monitor.
Turn OFF the servo system.
Replace the linear scale.
Turn OFF the servo system.
Replace the SERVOPACK.
Reduce the ambient operating temperature to 40 ° C or less.
Clean dust and oil from the surface.
If overloaded, reduce load or replace with larger capacity
SERVOPACK and servomotor.
Check if the value of Un004
(electrical angle 2 from polarity origin) at an arbitrary position is between ± 10 degrees.
Correct the settings for the polarity detection related parameter.
8
8-35
9
Appendix
9.1 List of Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2
9.2 Parameter Recording Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-32
9
9-1
9-2
9 Appendix
9.1
List of Parameters
This section contains a tables of parameters.
Note: Do not change the following parameters from the factory settings.
• Reserved parameters
• Parameters not described in this manual
Parameter
No.
Size Name
2 Basic Function Select Switch 0
4th 3rd 2nd 1st digit digit digit digit n.
Pn000
Setting
Range
0000 to 00B3
Units
−
Factory
Setting
0000
When
Enabled
After restart
Direction Selection
0
1
Sets the linear scale counting up direction as the forward direction.
Sets the linear scale counting down direction as the forward direction.
(Reverse Movement Mode)
2 or 3 Reserved (Do not set.)
Reserved (Do not change.)
Reserved (Do not change.)
Pn001
Setup −
Reference
Section
4.3.1
Reserved (Do not change.)
2 Application Function Select Switch 1 0000 to 1122
4th 3rd 2nd 1st digit digit digit digit n.
− 0000 After restart
Servomotor power OFF or Alarm Gr.1 Stop Mode
0
1
2
Stops the servomotor by applying DB (dynamic brake).
Stops the servomotor by applying DB and then releases DB.
Makes the servomotor coast to a stop state without using the DB.
Setup
Reference
Section
4.3.5
−
Overtravel (OT) Stop Mode
0
1
2
Stops in accordance with the setting of Pn001.0.
Sets the force of Pn406 to the maximum value, decelerates the servomotor to a stop, and then sets it to servolock state.
Sets the force of Pn406 to the maximum value, decelerates the servomotor to a stop, and then sets it to coasting state.
Reference
Section
4.3.2
AC/DC Power Input Selection
0
1
Applicable to AC power input: Input AC power supply through L1, L2, and L3 terminals.
Applicable to DC power input: Input DC power supply between B1/ + and − 2, or input
DC power supply between B1/ + and − .
Reference
Section
3.1.4
Reserved (Do not change.)
9.1 List of Parameters
(cont’d)
Parameter
No.
Size Name
Setting
Range
2 Application Function Select Switch 2 0000 to 4113
4th 3rd 2nd 1st digit digit digit digit n.
Pn002
Units
−
Factory
Setting
0000
When
Enabled
After restart Setup −
MECHATROLINK Command Position and Speed Control Option
2
3
0
1
The set value of P_TLIM, NTLIM, and TFF are ignored.
P_TLIM and NTLIM operate as the force limit values.
TFF operates as the force feed forward.
When P-CL and N-CL in the OPTION field are available, P_TLIM and NTLIM operate as the force limit value.
Reference
Section
*1
Force Control Option
0
1
VLIM is not available.
VLIM operates as the speed limit value.
Reference
Section
*1
Absolute Linear Scale Usage
0
1
Uses absolute linear scale as an absolute linear scale.
Uses absolute linear scale as an incremental linear scale.
Reserved (Do not change.)
Reference
Section
4.7
Pn006
2 Application Function Select Switch 6 0000 to 005F
4th 3rd 2nd 1st digit digit digit digit n.
− 0002 Immediately Setup
09
0A
0B
0C
0D
03
04
05
06
07
08
Analog Monitor 1 Signal Selection
00 Motor moving speed (1 V / 1000 mm/s)
01
02
Speed reference (1 V / 1000 mm/s)
Force reference (1 V/100% rated force)
Position error (0.05 V/1 reference unit)
Position amplifier error (after electronic gears) (0.05 V/ 1 linear scale pulse unit)
Position reference speed (1 V / 1000 mm/s)
Reserved (Do not set.)
Reserved (Do not set.)
Positioning completion (positioning completed: 5 V, positioning not completed: 0 V)
Speed feedforward (1 V / 1000 mm/s)
Force feedforward (1 V/100% rated force)
Active gain (1st gain: 1 V, 2nd gain: 2 V)
Completion of position reference (completed: 5 V, not completed: 0 V)
Reserved (Do not set.)
Reserved (Do not change.)
5.1.3
Reserved (Do not change.)
∗1.
For details, refer to the Σ -V Series/DC Power Input Σ -V Series/ Σ -V Series for Large-Capacity Models User’s Manual MECHATROLINK-II Commands (Manual No.: SIEP S800000 54).
9
9-3
9-4
9 Appendix
(cont’d)
Parameter
No.
Size Name
Setting
Range
2 Application Function Select Switch 7 0000 to 005F
4th 3rd 2nd 1st digit digit digit digit n.
Pn007
Units
−
Factory
Setting
0000
When
Enabled
Immediately Setup
Analog Monitor 2 Signal Selection
03
04
05
06
00
01
02
Motor moving speed (1 V / 1000 mm/s)
Speed reference (1 V / 1000 mm/s)
Force reference (1 V/100% rated force)
Position error (0.05 V/1 reference unit)
Position amplifier error (after electronic gears) (0.05 V/ 1 linear scale pulse unit)
Position reference speed (1 V / 1000 mm/s)
Reserved (Do not set.)
07
08
Reserved (Do not set.)
Positioning completion (positioning completed: 5 V, positioning not completed: 0 V)
09 Speed feedforward (1 V / 1000 mm/s)
0A Force feedforward (1 V/100% rated force)
0B Active gain (1st gain: 1 V, 2nd gain: 2 V)
0C Completion of position reference (completed: 5 V not completed: 0 V)
0D Reserved (Do not set.)
Reserved (Do not change.)
Reserved (Do not change.)
− 4000 After restart Setup 2 Application Function Select Switch 8 0000 to 7121
4th 3rd 2nd 1st digit digit digit digit n.
Reserved (Do not change.)
Pn008
5.1.3
−
Function Selection for Undervoltage
0
1
2
Does not detect undervoltage.
Detects warning and limits force by host controller.
Detects warning and limits force by Pn424 and Pn425. (Only in the SERVOPACK)
Warning Detection Selection
0
1
Detects warning.
Does not detect warning (except for A.971).
Reserved (Do not change.)
Reference
Section
4.3.8
Reference
Section
8.2.1
9.1 List of Parameters
(cont’d)
Parameter
No.
Size Name
Setting
Range
2 Application Function Select Switch 9 0000 to 0111
4th 3rd 2nd 1st digit digit digit digit n.
Reserved (Do not change.)
Units
−
Factory
Setting
0010
When
Enabled
After restart
Pn009
Current Control Method Selection
0
1
Current control method 1
Current control method 2
Speed Detection Method Selection
0
1
Speed detection 1
Speed detection 2
Reserved (Do not change.)
Pn00B
Pn00C
Tuning −
Reference
Section
5.8.3
Reference
Section
5.8.5
2 Application Function Select Switch B 0000 to 1111
4th 3rd 2nd 1st digit digit digit digit n.
Parameter Display Selection
0
1
Setup parameters
All parameters
− 0000 After restart
Alarm Gr.2 Stop Method Selection
0
1
Stops the motor by setting the speed reference to "0".
Same setting as Pn001.0 (Stops the motor by applying DB or by coasting).
Power Supply Method for Three-phase SERVOPACK
0
1
Three-phase power supply
Single-phase power supply
Reserved (Do not change.)
Setup −
Reference
Section
2.4.1
Reference
Section
4.3.5
Reference
Section
3.1.3
0000 After restart Setup
4.5,
4.5.1
2 Application Function Select Switch C 0000 to 0111
4th 3rd 2nd 1st digit digit digit digit n.
Selection of Test without a Motor
0
1
Disables test without a motor.
Enables test without a motor.
−
Reserved (Do not change.)
Encoder Type for Test without a Motor
0
1
Incremental linear scale
Absolute linear scale
Reserved (Do not change.)
9
9-5
9-6
9 Appendix
(cont’d)
Parameter
No.
Size Name
Setting
Range
2 Application Function Select Switch D 0000 to 1001
4th 3rd 2nd 1st digit digit digit digit n.
Reserved (Do not change.)
Units
−
Pn00D
Reserved (Do not change.)
Reserved (Do not change.)
Factory
Setting
0000
When
Enabled
Immediately
Pn00F
Pn080
Overtravel Warning Detection Selection
0
1
Does not detect overtravel warning.
Detects overtravel warning.
2 Reserved (Do not change.)
2
Application Function Select Switch
80
4th 3rd 2nd 1st digit digit digit digit n.
–
0000 to 1111
Hall Sensor Selection
0
1
Enables selection.
Disables selection.
–
−
0000
0000
Motor Phase Selection
0
1
Sets phase A lead as phase sequence of U,V,W.
Sets phase B lead as phase sequence of U,V,W.
Reserved (Do not change.)
–
After restart
Calculation Method for Maximum Speed or Divided Output Pulses
0
1
Determines divided output pulses with fixed maximum speed.
Determines maximum speed with fixed divided output pulses.
2
Application Function Select Switch
81
0000 to 1111 − 0000 After restart n.
4th digit
3rd digit
2nd digit
1st digit
Pn081
Phase-C Pulse Output Selection
0
1
Outputs phase-C pulse only in forward direction.
Outputs phase-C pulse in forward and reverse direction.
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
Setup
Setup
–
–
Setup
Reference
Section
4.3.2
–
−
4.4.4
9.1 List of Parameters
(cont’d)
Parameter
No.
Pn100
Pn101
Pn102
Pn103
Pn104
Pn105
Pn106
Pn109
Size Name
Setting
Range
Units
10 to 20000 0.1 Hz 2 Speed Loop Gain
2 Speed Loop Integral Time Constant 15 to 51200 0.01 ms
2 Position Loop Gain 10 to 20000 0.1/s
2
2
Mass Ratio
2nd Speed Loop Gain
2
2nd Speed Loop Integral Time
Constant
2 2nd Position Loop Gain
0 to 20000 1%
10 to 20000 0.1 Hz
15 to 51200
10 to 20000
0 to 100
0.01 ms
0.1/s
1%
Pn10A
2 Feedforward Gain
2
Feedforward Filter Time
Constant
2
Application Function for Gain Select
Switch
0 to 6400
0000 to 5334
0.01 ms
−
4th 3rd 2nd 1st digit digit digit digit n.
Pn10B
Factory
Setting
400
2000
400
100
400
2000
400
0
0
0000
When
Enabled
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
−
Tuning
Tuning
Tuning
Tuning
Tuning
Tuning
Tuning
Tuning
Tuning
−
Mode Switch Selection
0
1
2
3
4
When
Enabled
Uses internal force reference as the condition
(Level setting: Pn10C).
Uses speed reference as the condition (Level setting: Pn181).
Uses acceleration as the condition (Level setting:
Pn182).
Uses position error as the condition (Level setting:
Pn10F).
No mode switch function available.
Immediately
Classification
Setup
5.8.1
5.9.1
5.9.2
−
Reference
Section
When
Enabled
Classification
Reference
Section
Speed Loop Control Method
0
1
PI control
I-P control
2 or 3 Reserved (Do not set.)
Reserved (Do not change.)
After restart Setup −
Reserved (Do not change.)
Pn10C 2 Mode Switch (force reference) Immediately Tuning
Pn10F
Pn11F
Pn121
Pn122
Pn123
Pn124
Pn125
2 Mode Switch (position error)
2
Position Integral Time
Constant
2 Friction Compensation Gain
2
2nd Gain for Friction
Compensation
2
2
2
Friction Compensation
Coefficient
Friction Compensation
Frequency Correction
Friction Compensation Gain
Correction
0 to 800
0 to 10000
1%
1 reference unit
0 to 50000 0.1 ms
10 to 1000 1%
10 to 1000 1%
0 to 100
-10000 to
10000
1 to 1000
1%
0.1 Hz
1%
200
0
0
100
0
100
100
0
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Tuning
Tuning
Tuning
Tuning
Tuning
Tuning
Tuning
5.9.2
5.9.4
5.8.2
9
9-7
9-8
9 Appendix
Parameter
No.
Pn131
Size
Pn132
Pn135
Pn136
Name
2 Gain Switching Time 1
2 Gain Switching Time 2
2 Gain Switching Waiting Time 1
2 Gain Switching Waiting Time 2
2
Automatic Gain Changeover Related
Switch 1
Setting
Range
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0000 to 0052
4th 3rd 2nd 1st digit digit digit digit n.
Units
1 ms
1 ms
1 ms
1 ms
−
Factory
Setting
0
0
0
0
When
Enabled
Immediately
Immediately
Immediately
Immediately
0000 Immediately
Tuning
Tuning
Tuning
Tuning
Tuning
Gain Switching Selection Switch
0
1
2
Manual gain switching
Changes gain manually using G-SEL of OPTION field.
Reserved (Do not set.)
Automatic gain switching pattern 1
Changes automatically 1st gain to 2nd gain when the switching condition A is satisfied.
Changes automatically 2nd gain to 1st gain when the switching condition A is not satisfied.
Pn139
Gain Switching Condition A
0
3
4
5
1
2
Positioning completion signal (/COIN) ON
Positioning completion signal (/COIN) OFF
Positioning near signal (/NEAR) ON
Positioning near signal (/NEAR) OFF
Position reference filter output = 0 and position reference input OFF
Position reference input ON
(cont’d)
5.8.1
Reserved (Do not change.)
Reserved (Do not change.)
Pn13D
Pn140
2 Current Gain Level
2
Model Following Control Related
Switch
4th 3rd 2nd 1st digit digit digit digit n.
100 to 2000
0000 to 1121
1%
−
Model Following Control Selection
0
1
Does not use model following control.
Uses model following control.
2000
0100
Immediately
Immediately
Vibration Suppression Selection
0
1
2
Does not perform vibration suppression.
Performs vibration suppression over the specified frequency.
Performs vibration suppression over two different kinds of frequencies.
Tuning
Tuning
Vibration Suppression Adjustment Selection
0
1
Does not adjust vibration suppression automatically using utility function.
Adjusts vibration suppression automatically using utility function.
Selection of Speed Feedforward (VFF) / Force Feedforward (TFF)
0
1
Does not use model following control and speed/force feedforward together.
Uses model following control and speed/force feedforward together.
5.8.4
−
Reference
Section
5.3.1, 5.4.1,
5.5.1, 5.7.1
Reference
Section
5.3.1, 5.4.1
9.1 List of Parameters
(cont’d)
Parameter
No.
Pn141
Size
Pn142
Pn143
Name
2 Model Following Control Gain
2
2
Model Following Control Gain
Compensation
Model Following Control Bias
(Forward Direction)
Pn144
Pn145
Pn146
Pn147
Pn148
Pn149
Pn14A
Pn14B
Setting
Range
10 to 20000
500 to 2000
0 to 10000
2
2
2
2
Model Following Control Bias
(Reverse Direction)
Vibration Suppression 1
Frequency A
Vibration Suppression 1
Frequency B
Model Following Control Speed
Feedforward Compensation
0 to 10000
10 to 2500
10 to 2500
0 to 10000
2 2nd Model Following Control Gain 10 to 20000
2
2nd Model Following Control Gain
Compensation
500 to 2000
2
2
Vibration Suppression 2
Frequency
Vibration Suppression 2
Compensation
2 Control Related Switch
10 to 2000
10 to 1000
0000 to 0011
4th 3rd 2nd 1st digit digit digit digit n.
Units
0.1/s
0.1%
0.1%
0.1%
0.1 Hz
0.1 Hz
0.1%
0.1/s
0.1%
0.1 Hz
1%
−
Model Following Control Type Selection
0 Model Following Control 1
1
Model Following Control 2
Pn14F
Factory
Setting
500
When
Enabled
Immediately
1000 Immediately
1000
1000
500
700
1000
500
1000
800
100
0011
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
After restart
Tuning-less Type Selection
0 Tuning-less type 1
1 Tuning-less type 2
Reserved (Do not change.)
Reserved (Do not change.)
Tuning
Tuning
Tuning
Tuning
Tuning
Tuning
Tuning
Tuning
Tuning
Tuning
Tuning
Tuning
Reference
Section
5.3.1,
5.4.1,
5.5.1
Reference
Section
5.2.2
−
−
−
−
−
−
−
–
−
−
−
−
9
9-9
9-10
9 Appendix
(cont’d)
Parameter
No.
Size
Pn160
Pn161
Pn162
Pn163
Pn164
Pn165
Pn170
Name
Setting
Range
Units
Factory
Setting
When
Enabled
2
Anti-Resonance Control Related
Switch
0000 to 0011 − 0010 Immediately Tuning
5.3.1,
5.4.1,
5.5.1,
5.7.1
4th 3rd 2nd 1st digit digit digit digit n.
Anti-Resonance Control Selection
0 Does not use anti-resonance control.
1 Uses anti-resonance control.
Anti-Resonance Control Adjustment Selection
0 Does not adjust anti-resonance control automatically using utility function.
1 Adjusts anti-resonance control automatically using utility function.
Reserved (Do not change.)
Reserved (Do not change.)
2 Anti-Resonance Frequency
2
Anti-Resonance Gain
Compensation
2 Anti-Resonance Damping Gain
10 to 20000
1 to 1000
0 to 300
2
2
Anti-Resonance Filter Time
Constant 1 Compensation
Anti-Resonance Filter Time
Constant 2 Compensation
-1000 to
1000
-1000 to
1000
2 Tuning-less Function Related Switch 0000 to 2411
0.1 Hz
1%
1%
0.01 ms
0.01 ms
−
4th 3rd 2nd 1st digit digit digit digit n.
1000
100
0
0
0
1401
Immediately
Immediately
Immediately
Immediately
Immediately
−
Tuning
Tuning
Tuning
Tuning
Tuning
–
Tuning-less Function Selection
0
1
Disables tuning-less function.
Enables tuning-less function.
When
Enabled
After restart
Classification
Setup
Reference
Section
5.2
Control Method during Speed Control
0 Uses as speed control.
1
Uses as speed control and uses the host controller for position control.
When
Enabled
After restart
Classification
Setup
Reference
Section
5.2
−
–
−
−
−
−
Pn181
Pn182
Pn190
Pn200
Rigidity Level
0 to 4 Sets the rigidity level.
Load Level
0 to 2 Sets the load level.
2 Mode Switch (Speed Reference)
2 Mode Switch (Acceleration)
2 Reserved (Do not change.)
2 Reserved (Do not change.)
0 to 10000 1 mm/s
0 to 30000 1 mm/s
2
–
–
–
–
0
0
0010
0010
When
Enabled
Immediately
Classification
Setup
Reference
Section
5.2
When
Enabled
Immediately
Classification
Setup
Immediately
Immediately
–
–
Tuning
Tuning
–
–
Reference
Section
5.2
5.9.2
–
–
9.1 List of Parameters
(cont’d)
Parameter
No.
Size Name
2 Position Control Function Switch
4th 3rd 2nd 1st digit digit digit digit n.
Setting
Range
0000 to 2210
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
Pn207
Units
−
Factory
Setting
0010
When
Enabled
After restart Setup
/COIN Output Timing
0
1
2
Outputs when the position error absolute value is the same or less than the positioning completed width (Pn522).
Outputs when the position error absolute value is the same or less than the positioning completed width (Pn522), and the reference after position reference filtering is 0.
Outputs when the position error absolute value is the same or less than the positioning completed width (Pn522), and the position reference input is 0.
4.8.6
−
Reference
Section
Pn20E
Pn210
Pn281
Pn282
Pn305
Pn306
Pn310
Pn311
Pn324
Pn383
Pn384
Pn385
4 Electronic Gear Ratio (Numerator)
4
Electronic Gear Ratio
(Denominator)
2 Encoder Output Resolution
4 Linear Scale Pitch
2 Soft Start Acceleration Time
2 Soft Start Deceleration Time
2 Vibration Detection Switch
4th 3rd 2nd 1st digit digit digit digit n.
1 to
1073741824
1
1 to
1073741824
1
1 to 4096
1 edge/ pitch
0 to 6553600 0.01 μ m
0 to 10000 1 ms
0 to 10000
0000 to 0002
1 ms
−
4
1
20
0
0
0
0000
Vibration Detection Selection
0
1
2
Does not detect vibration.
Outputs warning (A.911) when vibration is detected.
Outputs alarm (A.520) when vibration is detected.
After restart
After restart
After restart
After restart
Immediately
Immediately
Immediately
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
Setup
Setup
Setup
Setup
Setup
Setup
Setup
4.4.3
4.4.5
−
*1
−
Reference
Section
6.16
2
Vibration Detection
Sensibility
2 Mass Calculating Start Level
2 JOG Speed
50 to 500 1%
0 to 20000 1%
0 to 10000 1 mm/s
100
300
50
Immediately
Immediately
Immediately
Tuning
Setup
Setup
6.16
5.3.2
6.3
2 Vibration Detection Level 0 to 5000 1 mm/s 10 Immediately Tuning 6.16
2 Motor Max. Speed 1 to 100 100 mm/s 50 After restart Setup 4.3.7
∗1.
For details, refer to the Σ -V Series/DC Power Input Σ -V Series/ Σ -V Series for Large-Capacity Models User’s Manual MECHATROLINK-II Commands (Manual No.: SIEP S800000 54).
9
9-11
9 Appendix
9-12
Pn409
Pn40A
Pn40B
Pn40C
Pn40D
Pn40E
Pn40F
(cont’d)
Parameter
No.
Size
Pn401
Pn404
Name
2
Force Reference Filter Time
Constant
2 Forward External Force Limit
Pn405
Pn406
2 Reverse External Force Limit
2 Emergency Stop Force
2
Force Related
Function Switch
4th 3rd 2nd 1st digit digit digit digit n.
Pn408
Setting
Range
Units
0 to 65535 0.01 ms
0 to 800
0 to 800
0 to 800
0000 to 1111
1%
*2
1%
*2
1%
*2
−
Factory
Setting
100
When
Enabled
Immediately
100
100
800
0000
Immediately
Immediately
Immediately
−
Tuning
Setup
Setup
Setup
−
5.9.3
4.6.2
4.3.2
−
1st Step Notch Filter Selection
0
1
N/A
Uses 1st step notch filter for force reference.
When
Enabled
Immediately
Classification
Setup
Reference
Section
5.9.3
Speed Limit Selection
0
1
Uses the smaller of the maximum motor speed and the value of Pn480 as the speed limit value.
Uses the smaller of the overspeed detection speed and the value of Pn480 as the speed limit value.
When
Enabled
After restart
Classification
Setup
Reference
Section
4.8.8
2nd Step Notch Filter Selection
0
1
N/A
Uses 2nd step notch filter for force reference.
When
Enabled
Immediately
Classification
Setup
Reference
Section
5.9.3
When
Enabled
Immediately
Classification
Setup
Reference
Section
5.8.2
Pn410
Pn412
Pn415
Pn423
Pn424
Pn425
Pn456
Friction Compensation Function Selection
0
1
Disables friction compensation function.
Enables friction compensation function.
2 1st Notch Filter Frequency
2 1st Notch Filter Q Value
2 1st Notch Filter Depth
50 to 5000
50 to 1000
0 to 1000
1 Hz
0.01
0.001
2 2nd Notch Filter Frequency
2 2nd Notch Filter Q Value
2 2nd Notch Filter Depth
2
2nd Step 2nd Force Reference Filter
Frequency
2
2
2nd Step 2nd Force Reference Filter
Q Value
1st Step 2nd Force Reference Filter
Time Constant
2 Reserved (Do not change.)
2 Reserved (Do not change.)
50 to 5000
50 to 1000
0 to 1000
100 to 5000
50 to 100
0 to 65535
−
−
2
2
Force Limit at Main Circuit Voltage
Drop
Release Time for Force Limit at
Main Circuit Voltage Drop
0 to 100
0 to 1000
2 Sweep Force Reference Amplitude
∗2.
Percentage (%) of rated motor force.
1 to 800
1 Hz
0.01
0.001
1 Hz
0.01
0.01 ms
−
−
1%
*2
1 ms
1%
50
100
15
100
0
0000
50
5000
70
0
5000
70
0
5000
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
−
−
Immediately
Immediately
Immediately
Tuning
Tuning
Tuning
Tuning
Tuning
Tuning
Tuning
Tuning
Tuning
−
−
Setup
Setup
Tuning
5.9.3
5.8.1
−
−
4.3.8
6.21
9.1 List of Parameters
Pn480
Pn481
Pn482
Pn483
Pn484
Pn485
Pn486
Pn487
Pn488
Pn48E
Pn490
Pn495
Parameter
No.
Size Name
2 Notch Filter Adjustment Switch
Pn460
Pn498
Pn506
Pn508
Pn509
Setting
Range
0000 to 0101
Units
−
Factory
Setting
0101
When
Enabled
Immediately Tuning
4th 3rd 2nd 1st digit digit digit digit n.
Notch Filter Adjustment Selection 1
0
1
Does not adjust 1st step notch filter automatically using utility function.
Adjust 1st step notch filter automatically using utility function.
Reserved (Do not change.)
Notch Filter Adjustment Selection 2
0 Does not adjust 2nd step notch filter automatically using utility function.
1 Adjust 2nd step notch filter automatically using utility function.
Reserved (Do not change.)
2 Speed Limit during Force Control
2 Polarity Detection Speed Loop Gain 1 to 20000
2
Polarity Detection Speed Loop
Integral Time Constant
15 to 51200
0.1 Hz
0.01 ms
2 Forward Force Limit
0 to 10000 1 mm/s
0 to 800 1%
*2
2 Reverse Force Limit 0 to 800 1%
*2
1 mm/s 2 Polarity Detection Reference Speed
2
2
Polarity Detection Reference Accel/
Decel Time
Polarity Detection Constant Speed
Time
2
Polarity Detection Reference
Waiting Time
2 Polarity Detection Range
2 Polarity Detection Load Level
2
Polarity Detection
Confirmation Force
Reference
2
2
Polarity Detection Allowable Error
Range
Brake Reference - Servo OFF Delay
Time
0 to 100
0 to 100
0 to 300
50 to 500
1 to 65535
0 to 20000
0 to 200
0 to 30
0 to 50
2
Waiting Time for Brake
Signal When Motor Running
10 to 100
2 Instantaneous Power Cut Hold time 20 to 1000
∗2.
Percentage (%) of rated motor force.
1 ms
1 ms
1 ms
1 mm
1%
1%
1 deg
10 ms
10 ms
1 ms
10000 Immediately
400 Immediately
3000 Immediately
30
30
20
25
Immediately
Immediately
Immediately
Immediately
0
100
10
100
100
10
0
50
20
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Tuning
Tuning
Tuning
Tuning
Tuning
Setup
Tuning
Tuning
Setup
Setup
Tuning
Tuning
Tuning
Setup
Setup
Setup
(cont’d)
5.2.1
5.3.1
5.5.1
4.8.8
−
−
4.6.1
−
−
−
−
−
−
−
−
4.3.4
4.3.6
9
9-13
9-14
9 Appendix
(cont’d)
Parameter
No.
Size Name
2 Input Signal Selection 1
4th 3rd 2nd 1st digit digit digit digit n.
Setting
Range
0000 to FFF1
Reserved (Do not change.)
Reserved (Do not change.)
Units
−
Reserved (Do not change.)
Factory
Setting
1881
When
Enabled
After restart
Pn50A
P-OT Signal Mapping
D
E
F
B
C
7
8
9
A
3
4
5
6
0
1
2
Forward run allowed when CN1-13 input signal is ON (closed).
Forward run allowed when CN1-7 input signal is ON (closed).
Forward run allowed when CN1-8 input signal is ON (closed).
Forward run allowed when CN1-9 input signal is ON (closed).
Forward run allowed when CN1-10 input signal is ON (closed).
Forward run allowed when CN1-11 input signal is ON (closed).
Forward run allowed when CN1-12 input signal is ON (closed).
Forward run prohibited.
Forward run allowed.
Forward run allowed when CN1-13 input signal is OFF (open).
Forward run allowed when CN1-7 input signal is OFF (open).
Forward run allowed when CN1-8 input signal is OFF (open).
Forward run allowed when CN1-9 input signal is OFF (open).
Forward run allowed when CN1-10 input signal is OFF (open).
Forward run allowed when CN1-11 input signal is OFF (open).
Forward run allowed when CN1-12 input signal is OFF (open).
Setup
4.3.2
−
Reference
Section
9.1 List of Parameters
(cont’d)
Parameter
No.
Size Name
2 Input Signal Selection 2
4th 3rd 2nd 1st digit digit digit digit n.
Pn50B
Setting
Range
0000 to
FFFF
Units
−
Factory
Setting
8882
When
Enabled
After restart
N-OT Signal Mapping
9
A
B
C
5
6
7
8
D
E
F
2
3
4
0
1
Reverse run allowed when CN1-13 input signal is ON (closed).
Reverse run allowed when CN1-7 input signal is ON (closed).
Reverse run allowed when CN1-8 input signal is ON (closed).
Reverse run allowed when CN1-9 input signal is ON (closed).
Reverse run allowed when CN1-10 input signal is ON (closed).
Reverse run allowed when CN1-11 input signal is ON (closed).
Reverse run allowed when CN1-12 input signal is ON (closed).
Reverse run prohibited.
Reverse run allowed.
Reverse run allowed when CN1-13 input signal is OFF (open).
Reverse run allowed when CN1-7 input signal is OFF (open).
Reverse run allowed when CN1-8 input signal is OFF (open).
Reverse run allowed when CN1-9 input signal is OFF (open).
Reverse run allowed when CN1-10 input signal is OFF (open).
Reverse run allowed when CN1-11 input signal is OFF (open).
Reverse run allowed when CN1-12 input signal is OFF (open).
Reserved (Do not change.)
/P-CL Signal Mapping
9
A
B
C
5
6
7
8
D
E
F
2
3
4
0
1
Active when CN1-13 input signal is ON (closed).
Active when CN1-7 input signal is ON (closed).
Active when CN1-8 input signal is ON (closed).
Active when CN1-9 input signal is ON (closed).
Active when CN1-10 input signal is ON (closed).
Active when CN1-11 input signal is ON (closed).
Active when CN1-12 input signal is ON (closed).
Always active (fixed).
Not active (fixed).
Active when CN1-13 input signal is OFF (open).
Active when CN1-7 input signal is OFF (open).
Active when CN1-8 input signal is OFF (open).
Active when CN1-9 input signal is OFF (open).
Active when CN1-10 input signal is OFF (open).
Active when CN1-11 input signal is OFF (open).
Active when CN1-12 input signal is OFF (open).
/N-CL Signal Mapping
0 to F Same as /P-CL signal mapping
Setup
4.3.2
4.6.2
–
Reference
Section
Reference
Section
Reference
Section
4.6.2
9
9-15
9-16
9 Appendix
(cont’d)
Parameter
No.
Size Name
2 Output Signal Selection 1
4th 3rd 2nd 1st digit digit digit digit n.
Setting
Range
0000 to 3333
Units
−
Factory
Setting
0000
When
Enabled
After restart
Positioning Completion Signal Mapping (/COIN)
2
3
0
1
Disabled (the above signal is not used.)
Outputs the signal from CN1-1, 2 output terminal.
Outputs the signal from CN1-23, 24 output terminal.
Outputs the signal from CN1-25, 26 output terminal.
Pn50E
Speed Coincidence Detection Signal Mapping (/V-CMP)
0 to 3 Same as /COIN Signal Mapping.
Servomotor Movement Detection Signal Mapping (/TGON)
0 to 3 Same as /COIN Signal Mapping.
Pn50F
Servo Ready Signal Mapping (/S-RDY)
0 to 3 Same as /COIN Signal Mapping.
2 Output Signal Selection 2
4th 3rd 2nd 1st digit digit digit digit n.
0000 to 3333 − 0100
Force Limit Detection Signal Mapping (/CLT)
0
1
2
3
Disabled (the above signal is not used.)
Outputs the signal from CN1-1, 2 output terminal.
Outputs the signal from CN1-23, 24 output terminal.
Outputs the signal from CN1-25, 26 output terminal.
After restart
Speed Limit Detection Signal Mapping (/VLT)
0 to 3 Same as /CLT Signal Mapping.
Brake Signal Mapping (/BK)
0 to 3 Same as /CLT Signal Mapping.
Warning Signal Mapping (/WARN)
0 to 3 Same as /CLT Signal Mapping.
Setup
Reference
Section
4.8.6
Reference
Section
4.6.3
Reference
Section
4.8.8
Reference
Section
4.3.4
Reference
Section
4.8.2
−
Reference
Section
4.8.5
Reference
Section
4.8.3
Setup
Reference
Section
4.8.4
−
9.1 List of Parameters
(cont’d)
Parameter
No.
Size Name
2 Output Signal Selection 3
4th 3rd 2nd 1st digit digit digit digit n.
Pn510
Setting
Range
0000 to 0333
Units
−
Factory
Setting
0000
When
Enabled
After restart
Near Signal Mapping (/NEAR)
2
3
0
1
Disabled (the above signal is not used.)
Outputs the signal from CN1-1, 2 terminal.
Outputs the signal from CN1-23, 24 terminal.
Outputs the signal from CN1-25, 26 terminal.
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
Setup
Reference
Section
4.8.7
−
9
9-17
9-18
9 Appendix
Parameter
No.
Size Name
2 Input Signal Selection 5
4th 3rd 2nd 1st digit digit digit digit n.
Pn511
Setting
Range
0000 to
FFFF
Units
−
Factory
Setting
6543
When
Enabled
After restart
Homing Deceleration Switch Signal Mapping (/DEC)
0
1
C
D
E
F
8
9
A
B
4
5
6
7
2
3
Active when CN1-13 input signal is ON (closed).
Active when CN1-7 input signal is ON (closed).
Active when CN1-8 input signal is ON (closed).
Active when CN1-9 input signal is ON (closed).
Active when CN1-10 input signal is ON (closed).
Active when CN1-11 input signal is ON (closed).
Active when CN1-12 input signal is ON (closed).
Always active.
Always not active.
Active when CN1-13 input signal is OFF (open).
Active when CN1-7 input signal is OFF (open).
Active when CN1-8 input signal is OFF (open).
Active when CN1-9 input signal is OFF (open).
Active when CN1-10 input signal is OFF (open).
Active when CN1-11 input signal is OFF (open).
Active when CN1-12 input signal is OFF (open).
External Latch Signal Mapping (/EXT1)
0 to 3 Always not active.
4
5
Active when CN1-10 input signal is ON (closed).
Active when CN1-11 input signal is ON (closed).
6 Active when CN1-12 input signal is ON (closed).
7 to C Always not active.
Active when CN1-10 input signal is OFF (open).
D
E
F
Active when CN1-11 input signal is OFF (open).
Active when CN1-12 input signal is OFF (open).
External Latch 2 Signal Mapping (/EXT2)
0 to F Same as /EXT1 signal mapping.
External Latch 3 Signal Mapping (/EXT3)
0 to F Same as /EXT1 signal mapping.
Setup
(cont’d)
3.3.1
9.1 List of Parameters
Parameter
No.
Size Name
2 Output Signal Inverse Setting
4th 3rd 2nd 1st digit digit digit digit n.
Setting
Range
0000 to 0111
Units
−
Factory
Setting
0000
When
Enabled
After restart
Output Signal Inversion for CN1-1 or -2 Terminal
0 Does not inverse outputs.
1 Inverses outputs.
Pn512
Output Signal Inversion for CN1-23 or -24 Terminal
0 Does not inverse outputs.
1 Inverses outputs.
Pn514
Pn517
Pn51E
Pn520
Pn522
Pn524
Pn526
Pn528
Pn52B
Pn52C
Pn52D
Pn52F
Output Signal Inversion for CN1-25 or -26 Terminal
0
1
Does not inverse outputs.
Inverses outputs.
Reserved (Do not change.)
2 Reserved (Do not change.)
2 Reserved (Do not change.)
2
Excessive Position Error Warning
Level
4
Excessive Position Error Alarm
Level
4
4
4
Positioning Completed Width
NEAR Signal Width
Excessive Position Error Alarm
Level at Servo ON
2
Excessive Position Error Warning
Level at Servo ON
2 Overload Warning Level
2
Derating of Base Current at
Detecting Overload of Motor
2 Reserved (Do not change.)
2 Reserved (Do not change.)
–
–
10 to 100
–
–
1%
0000
0000
100
–
–
Immediately
1 to
1073741823
0 to
1073741824
1 to
1073741824
1 to
1073741823
1 reference unit
1 reference unit
1 reference unit
1 reference unit
5242880
7
1073741824
5242880
Immediately
Immediately
Immediately
Immediately
10 to 100
1 to 100
10 to 100
–
−
1%
1%
1%
–
−
100
20
100
50
0FFF
Immediately
Immediately
After restart
–
−
Setup
Setup
Setup
Setup
Setup
Setup
–
−
–
–
Setup
Setup
Setup
(cont’d)
3.3.2
−
–
8.2.1
5.1.4
8.1.1
4.8.6
4.8.7
5.1.4
4.3.9
–
–
9
9-19
9 Appendix
9-20
Pn552
Pn553
Pn560
Pn561
Pn580
Pn581
Pn582
Pn583
Pn584
Pn585
Pn586
Pn534
Pn535
Pn536
Pn550
Pn551
Parameter
No.
Size Name
2
Program JOG Operation Related
Switch
4th 3rd 2nd 1st digit digit digit digit n.
Pn530
Setting
Range
0000 to 0005
Units
−
Factory
Setting
0000
When
Enabled
Immediately Setup
Program JOG Operation Switch
0
1
2
3
4
(Waiting time Pn535 → Forward movement Pn531) × Number of movements Pn536
(Waiting time Pn535 → Reverse movement Pn531) × Number of movements Pn536
(Waiting time Pn535 → Forward movement Pn531) × Number of movements Pn536
(Waiting time Pn535 → Reverse movement Pn531) × Number of movements Pn536
(Waiting time Pn535 → Reverse movement Pn531) × Number of movements Pn536
(Waiting time Pn535 → Forward movement Pn531) × Number of movements Pn536
(Waiting time Pn535 → Forward movement Pn531 → Waiting time Pn535 →
Reverse movement Pn531) × Number of movements Pn536
5 (Waiting time Pn535 → Reverse movement Pn531 → Waiting time Pn535 →
Forward movement Pn531) × Number of movements Pn536
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
Pn531 4
Program JOG Movement
Distance
2
Program JOG Acceleration/
Deceleration Time
2 Program JOG Waiting Time
2
Number of Times of Program JOG
Movement
2 Analog Monitor 1 Offset Voltage
2
2
2
2
Analog Monitor 2 Offset Voltage
Analog Monitor
Magnification ( × 1)
Analog Monitor
Magnification ( × 2)
Remained Vibration
Detection Width
2 Overshoot Detection Level
2 Zero Clamp Level
2 Zero Speed Level
2
Speed Coincidence Signal Output
Width
2
Brake Reference Output Speed
Level
2 Speed Limit Level at Servo ON
2 Program JOG Movement Speed
2 Motor Running Air-cooling Ratio
1 to
1073741824
1 reference unit
2 to 10000
0 to 10000
1 ms
1 ms
0 to 1000
-10000 to
10000
-10000 to
10000
-10000 to
10000
-10000 to
10000
1 to 3000
1 time
0.1 V
0.1 V
×
×
0.01
0.01
0.1%
0 to 100
0 to 10000 1 mm/s
1 to 10000 1 mm/s
0 to 100
0 to 10000
1%
1 mm/s
1 mm/s
0 to 10000 1 mm/s
1 to 10000 1 mm/s
0 to 100
1%/ maximum speed
32768
100
100
1
0
0
100
100
400
100
10
20
10
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
10 Immediately
10000 Immediately
50 Immediately
0 Immediately
Setup
Setup
Setup
Setup
Setup
Setup
Setup
Setup
Setup
Setup
Setup
Setup
Setup
Setup
Setup
Setup
Setup
(cont’d)
6.5
6.5
5.1.3
4.3.4
5.1.4
6.5
−
5.7.1
5.3.1
5.4.1
–
4.8.3
4.8.5
9.1 List of Parameters
(cont’d)
Parameter
No.
Size
2
Name
Polarity Detection for
Absolute Scale Selection n.
4th digit
3rd digit
2nd digit
1st digit
Pn587
Setting
Range
0000 to 0001
Units
−
Factory
Setting
0000
When
Enabled
Immediately
Polarity Detection for Absolute Scale Selection
0
1
Does not detect polarity.
Detects polarity.
Setup −
Reserved (Do not change.)
Reserved (Do not change.)
Pn600
Pn601
Pn612
Pn614
Pn615
Pn621 to
Pn628
*5
Reserved (Do not change.)
2 Regenerative Resistor Capacity
*3
2 Reserved (Do not change.)
2 Reserved (Do not change.)
2 Reserved (Do not change.)
2 Reserved (Do not change.)
Depends on
SERVO-
PACK
Capacity
*4
–
–
–
–
10 W
–
–
–
–
0
0
30
500
2000
Immediately
–
–
–
–
Setup
–
–
–
–
3.7.2
–
Parameters related to the safety module
– – – – – –
∗3.
Normally set to 0. If you use an external regenerative resistor, set the capacity (W) of the regenerative resistor.
∗4.
The upper limit is the maximum output capacity (W) of the SERVOPACK.
∗5.
These parameters are used in SERVOPACKs with safety modules. For details, refer to the
Drives User's Manual Safety Module (Manual No. SIEP C720829 06).
Σ -V Series AC Servo
–
–
–
–
9
9-21
9-22
9 Appendix
Parameter
No.
Size Name
2 Communications Control
4th 3rd 2nd 1st digit digit digit digit n.
Setting
Range
–
Units
–
Factory
Setting
0040
When
Enabled
Immediately Setup
MECHATROLINK-II Communications Check Mask (for debug)
0 No mask
Ignores MECHATROLINK communications error (A.E6
).
1
2
3
Ignores WDT error (A.E5
).
Ignores both MECHATROLINK communications error (A.E6
) and WDT error (A.E5
).
(cont’d)
*1
Pn800
Warning Check Mask
0
5
6
7
3
4
1
2
No mask
Ignores data setting warning (A.94
Ignores command warning (A.95
Ignores both command warning (A.95
) and communications warning (A.96
).
Ignores data setting warning (A.94
), command warning (A.95
) and communications warning
(A.96
).
).
).
Ignores both data setting warning (A.94
Ignores communications warning (A.96
Ignores both data setting warning (A.94
) and command warning (A.95
).
).
) and communications warning (A.96
).
Reserved (Do not change.)
2
Reserved (Do not change.)
Application Function Select 6
(Software LS)
– n.
4th digit
3rd digit
2nd digit
1st digit
– 0003 Immediately Setup 4.3.3
Pn801
Software Limit Function
0 Enables forward and reverse software limit.
1
2
Disables forward software limit.
Disables reverse software limit.
3 Disables software limit in both directions.
Reserved (Do not change.)
Software Limit for Reference
0 Disables software limit for reference.
1 Enables software limit for reference.
Pn803
Reserved (Do not change.)
2 Origin Range 0 to 250
1 reference unit
10 Immediately Setup *1
∗1.
For details, refer to the Σ -V Series/DC Power Input Σ -V Series/ Σ -V Series for Large-Capacity Models User’s Manual MECHATROLINK-II Commands (Manual No.: SIEP S800000 54).
9.1 List of Parameters
(cont’d)
Parameter
No.
Size
Pn804
Pn806
Pn808
Pn80A
Pn80B
Pn80C
Pn80D
Pn80E
Pn80F
Pn810
Pn811
Pn812
Pn814
Name
4 Forward Software Limit
4 Reverse Software Limit
4
2
2
2
2
2
2
2
Absolute Encoder Origin
Offset
1st Linear Acceleration
Constant
2nd Linear Acceleration
Constant
Acceleration Constant Switching
Speed
1st Linear Deceleration
Constant
2nd Linear Deceleration
Constant
Deceleration Constant Switching
Speed
Exponential Function
Acceleration/Deceleration Bias
Setting
Range
-1073741823 to
1073741823
-1073741823 to
1073741823
-1073741823 to
1073741823
1 to 65535
1 to 65535
0 to 65535
1 to 65535
1 to 65535
0 to 65535
0 to 65535
Units
1 reference unit
1 reference unit
1 reference unit
10000 reference unit/s
2
10000 reference unit/s
2
100 reference unit/s
10000 reference unit/s
2
10000 reference unit/s
2
100 reference unit/s
100 reference unit/s
Factory
Setting
When
Enabled
1073741823 Immediately
-1073741823 Immediately
0
100
100
0
100
100
0
0
Immediately
∗ 6
Immediately
∗ 7
Immediately
∗ 7
Immediately
∗ 7
Immediately
∗ 7
Immediately
∗ 7
Immediately
∗ 7
Immediately
∗ 8
Setup
Setup
Setup
Setup
Setup
Setup
Setup
Setup
Setup
Setup
4.3.3
4.7.3
*1
2
Exponential Function
Acceleration/Deceleration Time
Constant
0 to 5100 0.1 ms 0 Immediately
∗ 8 Setup
2 Movement Average Time 0 to 5100 0.1 ms 0 Immediately
∗ 8 Setup
4
Final Travel Distance for External
Positioning
-1073741823 to
1073741823
1 reference unit
100 Immediately Setup
∗1.
For details, refer to the Σ -V Series/DC Power Input Σ -V Series/ Σ -V Series for Large-Capacity Models User’s Manual MECHATROLINK-II Commands (Manual No.: SIEP S800000 54).
∗6.
Enabled after the SENS_ON command is input.
∗7.
Change the setting when the reference is stopped (DEN is set to 1), because the change will affect the output during operation.
∗8.
The value is updated only when the reference is stopped (DEN = 1).
9
9-23
9-24
9 Appendix
(cont’d)
Parameter
No.
Size Name
2 Homing Mode Setting n.
4th digit
3rd digit
2nd digit
1st digit
Pn816
Homing Direction
0 Forward
1 Reverse
Setting
Range
–
Reserved (Do not change.)
Units
–
Factory
Setting
0000
When
Enabled
Immediately
Reserved (Do not change.)
Setup
Reserved (Do not change.)
Pn817
*9
Pn818
*10
Pn819
2
2
Homing Approach Speed 1
Homing Approach Speed 2
0 to 65535
0 to 65535
100 reference unit/s
100 reference unit/s
50
5
Immediately
∗ 7
Immediately
∗ 7
Setup
Setup *1
4 Final Travel Distance for Homing
-1073741823 to
1073741823
1 reference unit
100 Immediately Setup
∗1.
For details, refer to the Σ -V Series/DC Power Input Σ -V Series/ Σ -V Series for Large-Capacity Models User’s Manual MECHATROLINK-II Commands (Manual No.: SIEP S800000 54).
∗7.
Change the setting when the reference is stopped (DEN is set to 1), because the change will affect the output during operation.
∗9.
The set value of Pn842 is valid when the set value of Pn817 is 0. Software version 0023 or higher is required to use
Pn842.
∗10.
The set value of Pn844 is valid when the set value of Pn818 is 0. Software version 0023 or higher is required to use
Pn844.
9.1 List of Parameters
(cont’d)
Parameter
No.
Size Name
2 Input Signal Monitor Selection n.
4th digit
3rd digit
2nd digit
1st digit
Pn81E
Setting
Range
–
Units
–
Factory
Setting
0000
When
Enabled
Immediately
IO12 Signal Mapping
6
7
4
5
2
3
0
1
No mapping
Monitors CN1-13 input terminal.
Monitors CN1-7 input terminal.
Monitors CN1-8 input terminal.
Monitors CN1-9 input terminal.
Monitors CN1-10 input terminal.
Monitors CN1-11 input terminal.
Monitors CN1-12 input terminal.
IO13 Signal Mapping
0 to 7 Same as IO12 signal mapping.
IO14 Signal Mapping
0 to 7 Same as IO12 signal mapping.
2 Command Data Allocation n.
4th digit
3rd digit
2nd digit
1st digit
IO15 Signal Mapping
0 to 7 Same as IO12 signal mapping.
– –
Option Field Allocation
0 Disables OPTION bit allocation.
1 Enables OPTION bit allocation.
0000 After restart
Pn81F
Position Control Command TFF/TLIM Function Allocation
0
1
Disables allocation.
Enables allocation.
Reserved (Do not change.)
Setup
Setup
*1
*1
Pn820
Pn822
Reserved (Do not change.)
4 Forward Latching Allowable Area
-2147483648 to
2147483647
1 reference unit
0 Immediately Setup
4 Reverse Latching Allowable Area 0 Immediately Setup
*1
-2147483648 to
2147483647
1 reference unit
∗1.
For details, refer to the Σ -V Series/DC Power Input Σ -V Series/ Σ -V Series for Large-Capacity Models User’s Manual MECHATROLINK-II Commands (Manual No.: SIEP S800000 54).
9
9-25
9-26
9 Appendix
(cont’d)
Parameter
No.
Size Name
Setting
Range
– Option Monitor 1 Selection
0000h
0001h
Motor moving speed
[overspeed detection position/1000000h]
Speed reference
[overspeed detection position/1000000h]
Pn824 2
Units
–
0002h Force [max. force/1000000h]
0003h Position error (lower 32 bits) [reference unit]
0004h Position error (upper 32 bits) [reference unit]
000Ah Encoder count (lower 32 bits) [reference unit]
000Bh Encoder count (upper 32 bits) [reference unit]
000Ch FPG count (lower 32 bits) [reference unit]
000Dh FPG count (upper 32 bits) [reference unit]
0010h Un000: Motor moving speed [mm/s]
0011h Un001: Speed reference [mm/s]
0012h Un002: Force reference [%]
0013h
Un003: Electric angle 1 (number of linear-scale pulses from polarity origin: decimal display)
0014h Un004: Electric angle 2 [deg]
0015h Un005: Input signal monitor
0016h Un006: Output signal monitor
0017h Un007: Input position reference speed [mm/s]
0018h Un008: Position error [reference unit]
0019h Un009: Accumulated load ratio [%]
001Ah Un00A: Regenerative load ratio [%]
001Bh Un00B: DB resistance consumption power [%]
001Ch Un00C: Input reference counter [reference unit]
001Dh
0025h
Un00D: Feedback pulse counter [linear scale pulse]
Primary absolute position data (lower 32 bits)
[pulse]
0026h
Primary absolute position data (upper 32 bits)
[pulse]
0027h Un022: Installation environment monitor [%]
Pn825
Pn827
Pn829
Factory
Setting
0000
When
Enabled
Immediately Setup
*1
0080h
Previous value of latched feedback position
(LPOS) [linear scale pulse]
Option Monitor 2 Selection – –
2
0000h to 0080h Same as Option Monitor 1 Selection.
0000 Immediately Setup
2
Linear Deceleration Constant 1 for
Stopping
1 to 65535
10000 reference unit/s
2
100 Immediately
∗ 7 Setup
2
SVOFF Waiting Time (SVOFF at deceleration to stop)
0 to 65535 10 ms 0 Immediately
∗ 7 Setup
∗1.
For details, refer to the Σ -V Series/DC Power Input Σ -V Series/ Σ -V Series for Large-Capacity Models User’s Manual MECHATROLINK-II Commands (Manual No.: SIEP S800000 54).
∗7.
Change the setting when the reference is stopped (DEN is set to 1), because the change will affect the output during operation.
9.1 List of Parameters
(cont’d)
Parameter
No.
Size Name
2 Option Field Allocation 1 n.
4th digit
3rd digit
2nd digit
1st digit
Setting
Range
0000 to
1E1E
0 to E ACCFIL bit position
Pn82A
0
1
Disables ACCFIL bit allocation.
Enables ACCFIL bit allocation.
Units
–
Factory
Setting
1813
When
Enabled
After restart
Pn82B
0 to E GSEL bit position
2 Option Field Allocation 2
0
1
Disables GSEL bit allocation.
Enables GSEL bit allocation.
0000 to
1F1F
– n.
4th digit
3rd digit
2nd digit
1st digit
0 to F V_PPI bit position
0
1
Disables V_PPI bit allocation.
Enables V_PPI bit allocation.
1D1C After restart
Setup
Setup
*1
*1
Pn82C
0 to F P_PI_CLR bit position
2 Option Field Allocation 3
0
1
Disables P_PI_CLR bit allocation.
Enables P_PI_CLR bit allocation.
0000 to
1F1F
– n.
4th digit
3rd digit
2nd digit
1st digit
0 to F P_CL bit position
0
1
Disables P_CL bit allocation.
Enables P_CL bit allocation.
1F1E After restart Setup *1
0 to F N_CL bit position
0
1
Disables N_CL bit allocation.
Enables N_CL bit allocation.
∗1.
For details, refer to the Σ -V Series/DC Power Input Σ -V Series/ Σ -V Series for Large-Capacity Models User’s Manual MECHATROLINK-II Commands (Manual No.: SIEP S800000 54).
9
9-27
9-28
9 Appendix
(cont’d)
Parameter
No.
Size Name
2 Option Field Allocation 4 n.
4th digit
3rd digit
2nd digit
1st digit
Setting
Range
0000 to
1F1C
0 to C BANK_SEL1 bit position
Units
–
Factory
Setting
0000
When
Enabled
After restart
Pn82D
0
1
Disables BANK_SEL1 bit allocation.
Enables BANK_SEL1 bit allocation.
Pn82E
0 to F LT_DISABLE bit position
2 Option Field Allocation 5
0
1
Disables LT_DISABLE bit allocation.
Enables LT_DISABLE bit allocation.
0000 to
1D1F
– n.
4th digit
3rd digit
2nd digit
1st digit
Reserved (Do not change.)
0000 After restart
Reserved (Do not change.)
Setup
Setup
*1
*1
Pn833
2 Motion Setting n.
4th digit
3rd digit
2nd digit
1st digit
0 to D OUT_SIGNAL bit position
0
1
Disables OUT_SIGNAL bit allocation.
Enables OUT_SIGNAL bit allocation.
0000 to 0001 – 0000 After restart
Linear Accel/Decel Constant Selection
0 Uses Pn80A to Pn80F and Pn827. (Setting of Pn834 to Pn840 disabled)
1 Uses Pn834 to Pn840. (Setting of Pn80A to Pn80F and Pn827 disabled)
Setup *1
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
∗1.
For details, refer to the Σ -V Series/DC Power Input Σ -V Series/ Σ -V Series for Large-Capacity Models User’s Manual MECHATROLINK-II Commands (Manual No.: SIEP S800000 54).
9.1 List of Parameters
(cont’d)
Parameter
No.
Size
Pn834
Pn836
Pn838
Pn83A
Pn83C
Pn83E
Pn840
Pn842
*9
Pn844
*10
Pn850
Pn851
Name
Setting
Range
Units
Factory
Setting
When
Enabled
4
4
4
4
4
4
4
1st Linear Acceleration
Constant 2
2nd Linear Acceleration
Constant 2
Acceleration Constant Switching
Speed 2
1st Linear Deceleration
Constant 2
2nd Linear Deceleration
Constant 2
Deceleration Constant Switching
Speed 2
Linear Deceleration
Constant 2 for Stopping
4 Homing Approach Speed 12
4 Homing Approach Speed 22
1 to
20971520
1 to
20971520
0 to
2097152000
1 to
20971520
1 to
20971520
0 to
2097152000
1 to
20971520
0 to
20971520
0 to
20971520
1 reference unit/s
10000 reference unit/s
2
100 reference unit/s
100 reference unit/s
–
10000 reference unit/s
2
10000 reference unit/s
1 reference unit/s
10000 reference unit/s
2
10000 reference unit/s
2
100
100
0
100
100
0
100
0
0
Immediately
∗ 7
Immediately
∗ 7
Immediately
∗ 7
Immediately
∗ 7
Immediately
∗ 7
Immediately
∗ 7
Immediately
∗ 7
Immediately
∗ 7
Immediately
∗ 7
Setup
Setup
Setup
Setup
Setup
Setup
Setup
Setup
Setup
*1
2 Latch Sequence Number 0 to 8 0 Immediately Setup
2 Continuous Latch Count 0 to 255 – 0 Immediately Setup
∗1.
For details, refer to the Σ -V Series/DC Power Input Σ -V Series/ Σ -V Series for Large-Capacity Models User’s Manual MECHATROLINK-II Commands (Manual No.: SIEP S800000 54).
∗7.
Change the setting when the reference is stopped (DEN is set to 1), because the change will affect the output during operation.
∗9.
The set value of Pn842 is valid when the set value of Pn817 is 0. Software version 0023 or higher is required to use
Pn842.
∗10.
The set value of Pn844 is valid when the set value of Pn818 is 0. Software version 0023 or higher is required to use
Pn844.
9
9-29
9 Appendix
(cont’d)
Parameter
No.
Size Name
Setting
Range
2 Latch Sequence Signal 1 to 4 Setting 0000 to 3333 n.
4th digit
3rd digit
2nd digit
1st digit
Units
–
Factory
Setting
0000
When
Enabled
Immediately
Latch sequence 1 signal selection.
0 Phase C
1
2
EXT1 signal
EXT2 signal
3 EXT3 signal
Pn852
Latch sequence 2 signal selection.
0 to 3 Same as latch sequence 1 signal selection.
Pn853
Latch sequence 3 signal selection.
0 to 3 Same as latch sequence 1 signal selection.
Latch sequence 4 signal selection.
0 to 3 Same as latch sequence 1 signal selection.
– 2 Latch Sequence Signal 5 to 8 Setting 0000 to 3333 n.
4th digit
3rd digit
2nd digit
1st digit
0000
Latch sequence 5 signal selection
0 Phase C
1 EXT1 signal
2
3
EXT2 signal
EXT3 signal
Immediately
Latch sequence 6 signal selection.
0 to 3 Same as latch sequence 5 signal selection.
Setup
Setup
*1
*1
Latch sequence 7 signal selection.
0 to 3 Same as latch sequence 5 signal selection.
9-30
Pn880
Pn881
Pn882
Latch sequence 8 signal selection.
0 to 3 Same as latch sequence 5 signal selection.
2
Station Address Monitor
(for maintenance, read only)
40 to 5Fh – 0 Immediately Setup –
2
Setting Transmission Byte Monitor
[byte]
(for maintenance, read only)
17, 32 – 0 Immediately Setup –
2
Transmission Cycle Setting Monitor
[0.25 μ s]
(for maintenance, read only)
0 to FFFFh – 0 Immediately Setup –
∗1.
For details, refer to the Σ -V Series/DC Power Input Σ -V Series/ Σ -V Series for Large-Capacity Models User’s Manual MECHATROLINK-II Commands (Manual No.: SIEP S800000 54).
9.1 List of Parameters
Parameter
No.
Size
Pn883
Name
2
Communications Cycle Setting
Monitor
[x transmission cycle]
(for maintenance, read only)
2 Communications Controls 2
4th 3rd 2nd 1st digit digit digit digit n.
Pn884
Setting
Range
0 to 32
0000 or 0001
Units
–
–
Factory
Setting
0
0000
When
Enabled
Immediately
Immediately
Setup
Setup
Settings for holding brake after MECHATROLINK Communications Error
0
1
Maintains the status set by the BRK_ON or BRK_OFF command when a MECHA-
TROLINK communications error occurs.
Applies the holding brake when a MECHATROLINK communications error occurs.
(cont’d)
–
–
Reserved (Do not change.)
Reserved (Do not change.)
Pn88A
Pn890 to
Pn89E
Pn8A0 to
Pn8AE
Pn900
Pn901
Pn902 to
Pn910
Pn920 to
Pn95F
Reserved (Do not change.)
2
4
MECHATROLINK Receive Error
Counter Monitor (for maintenance, read only)
Command Data Monitor at Alarm/
Warning Occurs
(for maintenance, read only)
4
Response Data Monitor at Alarm/
Warning Occurs
(for maintenance, read only)
2 Parameter Bank Number
2 Parameter Bank Member Number
0 to 65535
0 to
FFFFFFFFh
0 to
FFFFFFFFh
–
–
–
0
0
0
Immediately
Immediately
Immediately
Setup
Setup
Setup
–
0 to 16
0 to 15
–
–
0
0
After restart
After restart
Setup
Setup
*1
2 Parameter Bank Member Definition
0000h to
08FFh
– 0 After restart Setup
2
Parameter Bank Data (nonvolatile memory save disabled)
0000h to
FFFFh
– 0 Immediately Setup
∗1.
For details, refer to the Σ -V Series/DC Power Input Σ -V Series/ Σ -V Series for Large-Capacity Models User’s Manual MECHATROLINK-II Commands (Manual No.: SIEP S800000 54).
9
9-31
9 Appendix
9-32
Pn000
Pn001
Pn002
Pn006
Pn007
Pn008
Pn009
Pn00B
Pn00C
Pn00D
Pn00F
9.2
Parameter Recording Table
Use the following table for recording parameters.
Parameter
Pn080
Pn081
Pn100
Pn101
Pn102
Pn103
Pn104
Pn105
Pn106
Pn109
Pn10A
Pn10B
Pn10C
Pn10F
Pn11F
Pn121
Pn122
Pn123
Pn124
Pn125
Pn131
Pn132
Pn135
Pn136
Pn139
Pn13D
Factory
Setting
0000
0000
0000
0002
0000
4000
0010
0000
0000
0000
0000
0000
0000
400
2000
400
100
400
2000
Name
When
Enabled
Basic Function Select Switch 0 After restart
Application Function Select Switch 1 After restart
Application Function Select Switch 2 After restart
Application Function Select Switch 6 Immediately
Application Function Select Switch 7 Immediately
Application Function Select Switch 8 After restart
Application Function Select Switch 9 After restart
Application Function Select Switch B After restart
Application Function Select Switch C After restart
Application Function Select Switch D Immediately
– Reserved
Application Function Select Switch
80
After restart
Application Function Select Switch
81
Speed Loop Gain
After restart
Immediately
Speed Loop Integral Time Constant Immediately
Position Loop Gain Immediately
Immediately
Immediately
Mass Ratio
2nd Speed Loop Gain
2nd Speed Loop Integral Time Constant
2nd Position Loop Gain
Feedforward Gain
Feedforward Filter Time Constant
Immediately
Immediately
Immediately
Immediately
400
0
0
0000
200
0
0
100
100
0
0
Application Function for Gain Select
Switch
Mode Switch (force reference)
∗1
Mode Switch (position error)
Position Integral Time Constant
Immediately
Friction Compensation Gain Immediately
2nd Gain for Friction Compensation Immediately
Friction Compensation Coefficient
Friction Compensation Frequency
Correction
Immediately
Immediately
Immediately
Immediately
100
0
0
0
0
Friction Compensation Gain Correction
Gain Switching Time 1
Gain Switching Time 2
Gain Switching Waiting Time 1
Immediately
Immediately
Immediately
Immediately
Immediately
0000
Gain Switching Waiting Time 2
Automatic Gain Changeover Related
Switch 1
Immediately
2000 Current Gain Level Immediately
∗1.
Changes are enabled at different times depending on the digit. For details, refer to 9.1 List of Parameters .
9.2 Parameter Recording Table
Pn140
Pn141
Pn142
Pn165
Pn281
Pn282
Pn305
Pn306
Pn310
Pn311
Pn324
Pn383
Pn384
Pn385
Pn170
Pn181
Pn182
Pn190
Pn200
Pn207
Pn20E
Pn210
Pn144
Pn145
Pn146
Pn147
Pn148
Pn149
Pn14A
Pn14B
Pn14F
Pn160
Pn161
Pn162
Pn163
Pn164
Parameter
Pn143
Factory
Setting
0100
500
1000
1000
1000
500
700
1000
500
1000
800
100
0011
0010
1000
100
0
0
0
Name
(cont’d)
When
Enabled
Model Following Control Related
Switch
Model Following Control Gain
Model Following Control Gain Compensation
Immediately
Immediately
Immediately
Model Following Control Bias
(Forward Direction)
Model Following Control Bias
(Reverse Direction)
Immediately
Immediately
Vibration Suppression 1 Frequency A Immediately
Vibration Suppression 1 Frequency B Immediately
Model Following Control Speed
Feedforward Compensation
2nd Model Following Control Gain
2nd Model Following Control Gain
Compensation
Vibration Suppression 2 Frequency
Immediately
Immediately
Immediately
Immediately
Vibration Suppression 2 Compensation
Control Related Switch
Anti-Resonance Control Related
Switch
Anti-Resonance Frequency
Immediately
Immediately
Anti-Resonance Gain Compensation Immediately
Anti-Resonance Damping Gain Immediately
Anti-Resonance Filter Time Constant 1 Compensation
Anti-Resonance Filter Time Constant 2 Compensation
Immediately
After restart
Immediately
Immediately
1401
0
0
0010
0010
0010
4
1
0000
100
300
50
0
0
20
0
Tuning-less Function Related Switch
Mode Switch (Speed Reference)
Mode Switch (Acceleration)
Reserved
Reserved
Position Control Function Switch
∗1
Immediately
Immediately
–
–
After restart
Electronic Gear Ratio (Numerator) After restart
Electronic Gear Ratio (Denominator) After restart
Encoder Output Resolution
Linear Scale Pitch
Soft Start Acceleration Time
Soft Start Deceleration Time
Vibration Detection Switch
Vibration Detection Sensibility
Mass Calculating Start Level
JOG Speed
After restart
After restart
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
10
50
Vibration Detection Level
Motor Max. Speed
Immediately
After restart
∗1.
Changes are enabled at different times depending on the digit. For details, refer to 9.1 List of Parameters .
9
9-33
9-34
9 Appendix
Pn425
Pn456
Pn460
Pn480
Pn481
Pn482
Pn483
Pn484
Pn485
Pn486
Parameter
Pn401
Pn404
Pn405
Pn406
Pn408
Pn409
Pn40A
Pn40B
Pn40C
Pn40D
Pn40E
Pn40F
Pn410
Pn412
Pn415
Pn423
Pn424
Pn487
Pn488
Pn48E
Pn490
Pn495
Pn498
5000
70
0
5000
70
0
Factory
Setting
100
100
100
800
0000
5000
50
Name
When
Enabled
Force Reference Filter Time Constant Immediately
Forward External Force Limit
Reverse External Force Limit
Emergency Stop Force
Force Related Function Switch
(cont’d)
Immediately
Immediately
Immediately
∗1
1st Notch Filter Frequency Immediately
1st Notch Filter Q Value Immediately
1st Notch Filter Depth
2nd Notch Filter Frequency
Immediately
Immediately
2nd Notch Filter Q Value
2nd Notch Filter Depth
2nd Step 2nd Force Reference Filter
Frequency
2nd Step 2nd Force Reference Filter
Q Value
Immediately
Immediately
Immediately
Immediately
100
0
0
50
1st Step 2nd Force Reference Filter
Time Constant
Reserved
Reserved
Force Limit at Main Circuit Voltage
Drop
Immediately
−
−
Immediately
100
15
0101
10000
400
Release Time for Force Limit at Main
Circuit Voltage Drop
Sweep Force Reference Amplitude
Notch Filter Adjustment Switch
Speed Limit during Force Control
Immediately
Immediately
Immediately
Immediately
3000
30
30
20
Polarity Detection Speed Loop Gain Immediately
Polarity Detection Speed Loop Integral Time Constant
Immediately
Forward Force Limit
Reverse Force Limit
Immediately
Immediately
25
0
100
Polarity Detection Reference Speed Immediately
Polarity Detection Reference Accel/
Decel Time
Immediately
Polarity Detection Constant Speed
Time
Polarity Detection Reference Waiting Time
Polarity Detection Range
Polarity Detection Load Level
Immediately
Immediately
Immediately
Immediately
10
100
100
10
Polarity Detection Confirmation
Force Reference
Polarity Detection Allowable Error
Range
Immediately
Immediately
∗1.
Changes are enabled at different times depending on the digit. For details, refer to 9.1 List of Parameters .
Pn506
Pn508
Pn509
Pn50A
Pn50B
Pn50E
Pn50F
Pn510
Pn511
Pn512
Pn514
Pn517
Pn51E
Pn520
Pn522
Pn524
Pn526
Pn528
Pn52B
Pn52C
Pn52D
Pn52F
Pn530
Pn531
Pn534
Pn535
Pn536
Pn550
Pn551
Pn552
Pn553
Pn560
Pn561
Pn580
Pn581
Pn582
Pn583
Parameter
Factory
Setting
0
50
20
1881
8882
0000
0100
0000
6543
0000
0000
0000
100
5242880
7
1073741824
5242880
100
20
100
50
0FFF
0000
32768
100
100
1
0
0
100
100
400
100
10
20
10
10
9.2 Parameter Recording Table
Name
(cont’d)
When
Enabled
Brake Reference - Servo OFF Delay
Time
Waiting Time for Brake Signal When
Motor Running
Immediately
Immediately
Instantaneous Power Cut Hold Time Immediately
Input Signal Selection 1 After restart
Input Signal Selection 2
Output Signal Selection 1
After restart
After restart
Output Signal Selection 2
Output Signal Selection 3
Input Signal Selection 5
Output Signal Inverse Setting
Reserved
Reserved
Excessive Position Error Warning
Level
Excessive Position Error Alarm
Level
Positioning Completed Width
NEAR Signal Width
After restart
After restart
After restart
After restart
–
–
Immediately
Immediately
Immediately
Immediately
Excessive Position Error Alarm
Level at Servo ON
Excessive Position Error Warning
Level at Servo ON
Overload Warning Level
Derating of Base Current at Detecting
Overload of Motor
Reserved
Reserved
Immediately
Immediately
Immediately
After restart
–
–
Program JOG Operation Related
Switch
Program JOG Movement Distance
Program JOG Acceleration/Deceleration Time
Program JOG Waiting Time
Immediately
Immediately
Immediately
Immediately
Number of Times of Program JOG
Movement
Analog Monitor 1 Offset Voltage
Immediately
Immediately
Analog Monitor 2 Offset Voltage Immediately
Analog Monitor Magnification ( × 1) Immediately
Analog Monitor Magnification ( × 2) Immediately
Remained Vibration Detection Width Immediately
Overshoot Detection Level
Zero Clamp Level
Zero Speed Level
Speed Coincidence Signal Output
Width
Immediately
Immediately
Immediately
Immediately
Brake Reference Output Speed Level Immediately
9
9-35
9 Appendix
9-36
Parameter
Pn584
Pn585
Pn586
Pn587
Pn600
Pn601
Pn612
Pn614
Pn615
Pn800
Pn801
Pn803
Pn804
Pn806
Pn808
Pn80A
Pn80B
Pn80C
Pn80D
Pn80E
Pn80F
Pn810
Pn811
Pn812
Pn814
Pn816
Pn817
Pn818
Pn819
Pn81E
Pn81F
Factory
Setting
10000
50
0
Name
Speed Limit Level at Servo ON
Program JOG Movement Speed
Motor Running Air-cooling Ratio
(cont’d)
When
Enabled
Immediately
Immediately
Immediately
0000
0
0
30
500
2000
0040
Polarity Detection for Absolute Scale
Selection
Regenerative Resistor Capacity
Reserved
Reserved
Reserved
Reserved
Immediately
Immediately
–
–
–
–
Immediately
0003
10
1073741823
-1073741823
0
100
100
0
100
100
0
0
0
0
100
0000
50
5
100
Communications Control
Application Function Select 6
(Software LS)
Origin Range
Forward Software Limit
Reverse Software Limit
Absolute Encoder Origin Offset
1st Linear Acceleration Constant
2nd Linear Acceleration Constant
Acceleration Constant Switching
Speed
1st Linear Deceleration Constant
2nd Linear Deceleration Constant
Deceleration Constant Switching
Speed
Exponential Function Acceleration/
Deceleration Bias
Exponential Function Acceleration/
Deceleration Time Constant
Movement Average Time
Final Travel Distance for External
Positioning
Homing Mode Setting
Homing Approach Speed 1
Homing Approach Speed 2
Final Travel Distance for Homing
Immediately
Immediately
Immediately
Immediately
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
Immediately
∗ 2
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
0000 Input Signal Monitor Selection
0000 Command Data Allocation After restart
∗2.
Enabled after the SENS_ON is entered.
∗3.
Change the setting when the reference is stopped (DEN is set to 1), because the change will affect the output during operation.
9.2 Parameter Recording Table
Pn844
Pn850
Pn851
Pn852
Pn853
Pn880
Pn829
Pn82A
Pn82B
Pn82C
Pn82D
Pn82E
Pn833
Pn834
Parameter
Pn820
Pn822
Pn824
Pn825
Pn827
Pn836
Pn838
Pn83A
Pn83C
Pn83E
Pn840
Pn842
Pn881
Pn882
Pn883
Pn884
Factory
Setting
0
0
0000
0000
100
0
Name
Forward Latching Allowable Area
Reverse Latching Allowable Area
Option Monitor 1 Selection
(cont’d)
When
Enabled
Immediately
Immediately
Immediately
Option Monitor 2 Selection Immediately
Linear Deceleration Constant 1 for
Stopping
Immediately
∗ 3
SVOFF Waiting Time (SVOFF at deceleration to stop)
Immediately
Option Field Allocation 1 After restart 1813
1D1C
1F1E
0000
0000
0000
100
100
0
100
100
0
100
0
0
0
0
0000
0000
Option Field Allocation 2
Option Field Allocation 3
Option Field Allocation 4
Option Field Allocation 5
Motion Setting
After restart
After restart
After restart
After restart
1st Linear Acceleration Constant 2
2nd Linear Acceleration Constant 2
Acceleration Constant Switching
Speed 2
1st Linear Deceleration Constant 2
2nd Linear Deceleration Constant 2
Deceleration Constant Switching
Speed 2
Linear Deceleration Constant 2 for
Stopping
Homing Approach Speed 12
Homing ApproachCreep Speed 22
Latch Sequence Number
Continuous Latch Count
After restart
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
Immediately
Latch Sequence Signal 1 to 4 Setting Immediately
Latch Sequence Signal 5 to 8 Setting Immediately
0
0
0
0
Station Address Monitor
(for maintenance, read only)
Setting Transmission Byte Monitor
[byte] (for maintenance, read only)
Transmission Cycle Setting Monitor
[0.25 μ s]
(for maintenance, read only)
Communications Cycle Setting
Monitor [x transmission cycle]
(for maintenance, read only)
Immediately
Immediately
Immediately
Immediately
0000 Communications Control 2 Immediately
∗3.
Change the setting when the reference is stopped (DEN is set to 1), because the change will affect the output during operation.
9
9-37
9-38
9 Appendix
Parameter
Pn88A
Factory
Setting
0
Pn890 to
Pn89E
Pn8A0 to
Pn8AE
Pn900
Pn901
Pn902 to
Pn910
Pn920 to
Pn95F
0
0
0
0
0
0
Name
MECHATROLINK Receive Error
Counter Monitor
(for maintenance, read only)
Command Data Monitor at Alarm/
Warning Occurs
(for maintenance, read only)
Response Data Monitor at Alarm/
Warning Occurs
(for maintenance, read only)
Parameter Bank Number
Parameter Bank Member Number
(cont’d)
When
Enabled
Immediately
Immediately
Immediately
After restart
After restart
Parameter Bank Member Definition After restart
Parameter Bank Data (nonvolatile memory save disabled)
Immediately
Index
Index
Symbols
/BK - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-12
/CLT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-40
/COIN - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-50
/HWBB1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-58
/HWBB2 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-58
/N-CL - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-39
/NEAR- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-51
/P-CL- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-39
/S-RDY - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-48
/TGON - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-47
/V-CMP - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-49
/VLT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-52
/WARN - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-46
A absolute data reception sequence - - - - - - - - - - - - - - - - - - - - - - 4-42 absolute data request (SENS_ON) - - - - - - - - - - - - - - - - - - - - - 4-41 absolute encoder origin offset - - - - - - - - - - - - - - - - - - - - - - - - 4-45 absolute linear scale connection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-33 setup - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-41
AC reactor - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-43 additional adjustment function - - - - - - - - - - - - - - - - - - - - - - - - 5-54 advanced autotuning (Fn201)- - - - - - - - - - - - - - - - - - - - - - - - - 5-16 anti-resonance control adjustment function - - - - - - - - - - - - 5-23 calculating mass - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-19 feedforward - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-24 friction compensation- - - - - - - - - - - - - - - - - - - - - - - - - - - 5-24 mode selection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-19 notch filter - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-23
STROKE (travel distance) setting - - - - - - - - - - - - - - - - - - 5-20 type selection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-19 vibration suppression - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-23 advanced autotuning by reference (Fn202)- - - - - - - - - - - - - - - - 5-26 anti-resonance control adjustment function - - - - - - - - - - - - 5-30 feedforward - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-31 friction compensation- - - - - - - - - - - - - - - - - - - - - - - - - - - 5-31 mode selection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-28 notch filter - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-30 type selection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-28 vibration suppression - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-30 alarm history display (Fn000) - - - - - - - - - - - - - - - - - - - - - - - - - 6-3 alarm reset - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-2 alarm reset method- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-46
ALM - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-46 ambient operating temperature- - - - - - - - - - - - - - - - - - - - - - - - - 1-4 ambient/storage humidity - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-4 anti-resonance control adjustment function (Fn204) - - - - - - - - - 5-43 application example of safety functions- - - - - - - - - - - - - - - - - - 4-62 automatic gain switching - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-55 automatic offset-signal adjustment of the motor current detection signal (Fn00E) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-18 automatically setting the notch filter - - - - - - - - - - - - - - - - - - - - 5-11
B baseblock - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-2 baud rate - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-7
BB - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - iii , 4-37 brake operation delay time - - - - - - - - - - - - - - - - - - - - - - - - - - 4-10 brake signals - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-12
C
CE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - xv changing detection timing of overload (low load) alarm
(A.720) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-22 changing detection timing of overload warning (A.910) - - - - - - 4-21 checking output force limiting during operation - - - - - - - - - - - - 4-40 clearing alarm history (Fn006) - - - - - - - - - - - - - - - - - - - - - - - 6-13
CN1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-20
CN2 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-30
CN3 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-2
CN6A - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-2 , 3-29
CN6B - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-2 , 3-29
CN7 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-2
CN8 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-21 coast to a stop - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-7 communication protocol- - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-7 compatible adjustment function - - - - - - - - - - - - - - - - - - - - - - - 5-61 confirming safety functions- - - - - - - - - - - - - - - - - - - - - - - - - - 4-63 connecting a reactor for harmonic suppression - - - - - - - - - - - - - 3-43 connecting regenerative resistors - - - - - - - - - - - - - - - - - - - - - - 3-37 connection example of EDM1 output signal - - - - - - - - - - - - - - 4-61 connection example of HWBB input signals - - - - - - - - - - - - - - 4-58 connection to host controller (interface) sequence input circuit - - - - - - - - - - - - - - - - - - - - - - - - - - 3-26 sequence output circuit- - - - - - - - - - - - - - - - - - - - - - - - - - 3-27 connector CN5 for analog monitor - - - - - - - - - - - - - - - - - - - - - - 5-5 current control mode selection- - - - - - - - - - - - - - - - - - - - - - - - 5-60 current gain level setting - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-60
D
DC power supply input parameter setting- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-14 wiring example - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-15
DC reactor - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-43 decelerate to stop - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-7 digital operator displays during testing without motor - - - - - - - - 4-37
DIP switch - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-2 setting - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-3 display of SERVOPACK and servomotor ID (Fn01E) - - - - - - - - 6-28 dynamic brake - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-7
E
EasyFFT (Fn206) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-33
EDM1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-60 electronic gear - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-25 electronic gear ratio - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-25 encoder output pulse setting - - - - - - - - - - - - - - - - - - - - - - - - - 4-33 encoder output pulses- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-28 encoder output resolution - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-33 error detection in HWBB signal- - - - - - - - - - - - - - - - - - - - - - - 4-57
EU directives - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - xv external device monitor - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-60 external force limit - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-39 external latch signal 1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-24 external latch signal 2 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-24 external latch signal 3 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-24 external regenerative resistor- - - - - - - - - - - - - - - - - - - - - - - - - 3-37
F feedback resolutions of linear scale - - - - - - - - - - - - - - - - - - - - 4-26 feedforward - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-61 feedforward compensation - - - - - - - - - - - - - - - - - - - - - - - - - - 5-61
FG - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-21 , 3-22 force control tolerance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-4
Index-1
Index force limit function for low DC power supply voltage for main circuit- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-18 force reference filter - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-64 forward external force limit - - - - - - - - - - - - - - - - - - - - - - - - - - 4-39 forward reference - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-5 friction compensation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-58
G gain adjustment of analog monitor output (Fn00D) - - - - - - - - - - 6-16
Gr.1 alarm- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-15
Gr.2 alarm- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-15 grounding - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-41
G-SEL of OPTION field - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-55
H hard wire base block (HWBB) function - - - - - - - - - - - - - - - - - - 4-54 hard wire base block (HWBB) state - - - - - - - - - - - - - - - - - - - - 4-55 harmonized standards - - - - - - - - - - - - - - - - - - - - - - - - - - - - xv , 1-4 holding brakes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-10 homing deceleration switch signal - - - - - - - - - - - - - - - - - - - - - 3-24
I initial incremental pulses - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-43 initializing parameter settings (Fn005)- - - - - - - - - - - - - - - - - - - 6-12 input signal (CN1) allocations- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-23 monitoring - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-4 names and functions - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-20 instantaneous power interruption settings - - - - - - - - - - - - - - - - - 4-16 internal block diagrams - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-8 internal force limit - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-38
J
JOG operation (Fn002) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-4
L
LED (COM) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-2 , 1-5
LED (POWER) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-2 , 1-5 limit switches - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-6 limiting force- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-38 linear scale connection examples - - - - - - - - - - - - - - - - - - - - - - 3-33 absolute linear scale made by Magnescale Co., Ltd.- - - - - - - 3-36 absolute linear scale made by Mitutoyo - - - - - - - - - - - - - - - 3-36 incremental linear scale made by Heidenhain - - - - - - - - - - - 3-33 incremental linear scale made by Magnescale Co., Ltd. - - - - 3-34 incremental linear scale made by Renishaw plc- - - - - - - - - - 3-33 list of alarms - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-2 list of monitor displays - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-2 list of warnings - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-24
M main circuit names and functions of terminals - - - - - - - - - - - - - - - - - - - - 3-2 wires - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3-4 , 3-11 wiring examples- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-5 manual gain switching - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-55 manual offset-signal adjustment of the motor current detection signal (Fn00F) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-19
MECHATROLINK-II communications connector - - - - - - - -1-2 , 3-29
MECHATROLINK-II function specifications - - - - - - - - - - - - - - - 1-7 monitor displays (Un ) - - - - - - - - - - - - - - - - - - - - - - - - - - 2-7 monitor factor - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-6 monitoring safety input signals- - - - - - - - - - - - - - - - - - - - - - - - - 7-7 movement detection output signal- - - - - - - - - - - - - - - - - - - - - - 4-47
N noise filter - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-41
N-OT- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-6 notch filter - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-66
O offset adjustment of analog monitor output (Fn00C) - - - - - - - - - 6-14 oil seal replacement - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-21 one-parameter tuning (Fn203) - - - - - - - - - - - - - - - - - - - - - - - - 5-33 anti-resonance control adjustment function - - - - - - - - - - - - 5-38 feedforward - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-39 friction compensation - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-39 notch filter - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-38 tuning mode - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-34 , 5-36 type selection - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-34 , 5-36 one-parameter tuning example - - - - - - - - - - - - - - - - - - - - - - - - 5-40 online vibration monitor (Fn207) - - - - - - - - - - - - - - - - - - - - - - 6-36 origin search (Fn003) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-6 origin setting (Fn020)- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-30 output phase form - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-28 output signal (CN1) allocations - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-25 monitoring - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-6 names and functions- - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-21 overtravel (OT) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-6 overtravel warning function- - - - - - - - - - - - - - - - - - - - - - - - - - - 4-8
P panel display- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-2
PAO - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-28 parameter classification- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-4 how to make numeric settings using parameters - - - - - - - - - - 2-5 how to select functions using parameters - - - - - - - - - - - - - - - 2-6 parameters for numeric settings - - - - - - - - - - - - - - - - - - - - - - iv parameters for selecting functions - - - - - - - - - - - - - - - - -iv , 2-4 tuning parameters - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-4 parameter recording table - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-32
PBO - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-28
PCO - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-28 polarity detection (Fn080) - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-32 position integral- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-66 positioning completed signal - - - - - - - - - - - - - - - - - - - - - - - - - 4-50 positioning near signal - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-51
P-OT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-6 precautions for safety functions - - - - - - - - - - - - - - - - - - - - - - - 4-65 precautions for wiring - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-19 precautions on connecting noise filter - - - - - - - - - - - - - - - - - - - 3-42 program JOG operation (Fn004) - - - - - - - - - - - - - - - - - - - - - - - 6-8 protection class/pollution degree - - - - - - - - - - - - - - - - - - - - - - - 1-4
R reference unit - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-25 resetting configuration errors in option modules (Fn014) - - - - - - 6-25 resetting the HWBB state - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-56 reverse external force limit - - - - - - - - - - - - - - - - - - - - - - - - - - 4-39 reverse reference - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-5 risk assessment - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-55 rotary switch - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -1-2 , 4-4
RUN - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-37
S safety function - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-54 safety function signal (CN8) names and functions- - - - - - - - - - - 3-21 safety precautions on adjustment of servo gains - - - - - - - - - - - - - 5-8
Index-2
Index
SEMI F47 function - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-18 serial converter unit - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-30 model designations - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-31 specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-30 serial data - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-43 , 4-44 servo alarm output signal - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-46 servo gains - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-3 servo ready output signal - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-47 servomotor inspection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-21 servomotor model display (Fn011) - - - - - - - - - - - - - - - - - - - - - 6-23 servomotor movement direction - - - - - - - - - - - - - - - - - - - - - - - - 4-5
SERVOPACK basic specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-4 example of servo system configuration
(SGDV A15 ) - - - - - - - - - - - - - - - - - - - - - - - - - - 1-16 example of servo system configuration
(SGDV D15A) - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-18 example of servo system configuration
(SGDV F15A) - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-15 inspection and maintenance- - - - - - - - - - - - - - - - - - - - - - - 1-20
MECHATROLINK-II function specifications - - - - - - - - - - - 1-7 model designation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-19 part names - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-2 precautions when using more than one SERVOPACK - - - - - 3-18 ratings - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-3 status display - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-2 setting encoder output pulse - - - - - - - - - - - - - - - - - - - - - - - - - 4-33 setting motor overload detection level - - - - - - - - - - - - - - - - - - - 4-21 setting regenerative resistor capacity- - - - - - - - - - - - - - - - - - - - 3-39 single-phase, 200 V power supply input main circuit wire for SERVOPACKs- - - - - - - - - - - - - - - - - 3-11 molded-case circuit breaker- - - - - - - - - - - - - - - - - - - - - - - 3-13 parameter setting - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-11 power supply capacities and power losses - - - - - - - - - - - - - 3-12 wire types- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-3 wiring example - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-12 soft start time setting - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-4 software limit settings - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-9 software reset (Fn030) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-31 software version display (Fn012) - - - - - - - - - - - - - - - - - - - - - - 6-24 specifications of EDM1 output signal - - - - - - - - - - - - - - - - - - - 4-61 specifications of HWBB signals- - - - - - - - - - - - - - - - - - - - - - - 4-58 speed coincidence signal- - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-49 speed control range - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-4 speed detection method selection - - - - - - - - - - - - - - - - - - - - - - 5-60 speed limit in force control - - - - - - - - - - - - - - - - - - - - - - - - - - 4-52 speed regulation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-4 standard power supply input main circuit wires for SERVOPACKs - - - - - - - - - - - - - - - - - 3-4 molded-case circuit breaker- - - - - - - - - - - - - - - - - - - - - - - 3-10 power supply capacities and power losses - - - - - - - - - - - - - - 3-9 wire types- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-3 wiring examples - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-5 station address- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-7 stopping method for servomotor after SV_OFF command is received - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-14 stopping method for servomotor when an alarm occurs - - - - 4-15 , 8-2 storage temperature - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-4
SW1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-2 , 4-4
SW2 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-2 , 4-3 switching condition A - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-55 switching gain settings - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-54
T terminator - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-29 test without motor function - - - - - - - - - - - - - - - - - - - - - - - - - - 4-35 time stamps - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-3 transmission cycle - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-7 trial operation inspection and checking before trial operation - - - - - - - - - - 4-23 trial operation via MECHATROLINK-II- - - - - - - - - - - - - - 4-24 troubleshooting alarms - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-6 warnings - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-25 troubleshooting malfunction based on operation and conditions of the servomotor - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-30 tuning parameters - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-4 tuning-less function - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-10 tuning-less level settings (Fn200)- - - - - - - - - - - - - - - - - - - - - - 5-11
U
UL - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - xv using the mode switch (P/PI switching) - - - - - - - - - - - - - - - - - 5-62 utility functions (Fn )- - - - - - - - - - - - - - - - - - - - - - - - - - - 2-3
V vibration detection level initialization (Fn01B) - - - - - - - - - - - - 6-26 vibration suppression function (Fn205)- - - - - - - - - - - - - - - - - - 5-49 vibration/shock resistance- - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-4
W warning output signal- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-46 wiring for noise control - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-40 wiring MECHATROLINK-II communications- - - - - - - - - - - - - 3-29 write prohibited setting (Fn010)- - - - - - - - - - - - - - - - - - - - - - - 6-21
Z zero clamp mode- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-7 zero-speed stopping - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - iii
Index-3
Revision History
The revision dates and numbers of the revised manuals are given on the bottom of the back cover.
MANUAL NO. SIEP S800000 48B <1>-1
Published in Japan August 2009
WEB revision number
Revision number
Date of publication
Date of
Publication
January 2020
February 2019
March 2018
May 2016
September 2014
July 2014
July 2013
February 2012
September 2011
April 2011
August 2009
August 2008
August 2007
Rev.
No.
<10>
<9>
<8>
<7>
<6>
<5>
<4>
<3>
<2>
<1>
–
WEB
Rev.
No.
1
0
0
0
0
0
0
0
0
0
1
0
–
Section Revised Content
Preface
9.1
Back cover
Chapter 3,
Chapter 8
3.1.2
Back cover
All chapters
Back cover
Front cover
–
All chapters
Back cover
Revision: Disposal Precaution
Revision: Output unit of Pn824
Revision: Address
Partly revised
Revision: Servomotor connection terminal for SERVOPACK SGDV-180 (three-phase, 200 V)
Revision: Address
Partly revised
Revision: Address
Revision: Format
Based on Japanese user’s manual, SIJP S800000 48L <12> printed in December 2015.
Completely revised
Revision: Address and format
3.6.2 (3)
3.6.3 (2), 4.4.3
(1)
4.9.5
8.1.1, 8.1.2
Revision: Description of analog signal input timing
Addition: Absolute linear scale by Heidenhain (models: LIC4100-series models)
Addition: Information on types of safety function’s jumper connectors
Addition: A.861 and A.F50
9.1.2, 9.3
Addition: Pn884
Preface, 1.3.2
Revision: Description of Harmonized Standards
EN 55011 /A2 changed to EN 55011
Back cover
–
All chapters
Back cover
–
All chapters
Front cover
1.4.2, 7.1,
9.1.2, 9.2
Back cover
Revision: Address
Based on Japanese user’s manual, SIJP S800000 48H <7> printed in August 2011.
Completely revised
Revision: Address
Based on Japanese user’s manual, SIJP S800000 48G <6> printed in March 2011.
Completely revised
Revision: Format
Addition: Description of SGDV B SERVOPACKs
Preface
Back cover
All chapters
Back cover
–
Revision: Address, format
Addition: Original instructions
Addition: Warranty
Revision: Address
Completely revised
Revision: Address
First edition
AC Servo Drives
-
V
Series
USER’S MANUAL
Design and Maintenance
Linear Motor
MECHATROLINK-
II
Communications Reference
IRUMA BUSINESS CENTER (SOLUTION CENTER)
480, Kamifujisawa, Iruma, Saitama, 358-8555, Japan
Phone: +81-4-2962-5151 Fax: +81-4-2962-6138 www.yaskawa.co.jp
YASKAWA AMERICA, INC.
2121, Norman Drive South, Waukegan, IL 60085, U.S.A.
Phone: +1-800-YASKAWA (927-5292) or +1-847-887-7000 Fax: +1-847-887-7310 www.yaskawa.com
YASKAWA ELÉTRICO DO BRASIL LTDA.
777, Avenida Piraporinha, Diadema, São Paulo, 09950-000, Brasil
Phone: +55-11-3585-1100 Fax: +55-11-3585-1187 www.yaskawa.com.br
YASKAWA EUROPE GmbH
Hauptstra β e 185, 65760 Eschborn, Germany
Phone: +49-6196-569-300 Fax: +49-6196-569-398 www.yaskawa.eu.com E-mail: [email protected]
YASKAWA ELECTRIC KOREA CORPORATION
35F, Three IFC, 10 Gukjegeumyung-ro, Yeongdeungpo-gu, Seoul, 07326, Korea
Phone: +82-2-784-7844 Fax: +82-2-784-8495 www.yaskawa.co.kr
YASKAWA ASIA PACIFIC PTE. LTD.
30A, Kallang Place, #06-01, 339213, Singapore
Phone: +65-6282-3003 Fax: +65-6289-3003 www.yaskawa.com.sg
YASKAWA ELECTRIC (THAILAND) CO., LTD.
59, 1F-5F, Flourish Building, Soi Ratchadapisek 18, Ratchadapisek Road, Huaykwang, Bangkok, 10310, Thailand
Phone: +66-2-017-0099 Fax: +66-2-017-0799 www.yaskawa.co.th
YASKAWA ELECTRIC (CHINA) CO., LTD.
22F, Link Square 1, No.222, Hubin Road, Shanghai, 200021, China
Phone: +86-21-5385-2200 Fax: +86-21-5385-3299 www.yaskawa.com.cn
YASKAWA ELECTRIC (CHINA) CO., LTD. BEIJING OFFICE
Room 1011, Tower W3 Oriental Plaza, No.1, East Chang An Avenue,
Dong Cheng District, Beijing, 100738, China
Phone: +86-10-8518-4086 Fax: +86-10-8518-4082
YASKAWA ELECTRIC TAIWAN CORPORATION
12F, No. 207, Section 3, Beishin Road, Shindian District, New Taipei City 23143, Taiwan
Phone: +886-2-8913-1333 Fax: +886-2-8913-1513 or +886-2-8913-1519 www.yaskawa.com.tw
In the event that the end user of this product is to be the military and said product is to be employed in any weapons systems or the manufacture thereof, the export will fall under the relevant regulations as stipulated in the Foreign Exchange and Foreign
Trade Regulations. Therefore, be sure to follow all procedures and submit all relevant documentation according to any and all rules, regulations and laws that may apply.
Specifications are subject to change without notice for ongoing product modifications and improvements.
© 2007 YASKAWA ELECTRIC CORPORATION
MANUAL NO. SIEP S800000 48K <10>-1
Published in Japan January 2020
19-10-16
Original instructions