Yaskawa SGMVV Sigma-5 Manual
Anuncio
Anuncio
AC Servo Drives
Σ
-
V
Series
USER’S MANUAL
For Use with Large-Capacity Models
Design and Maintenance
Rotational Motor
MECHATROLINK-
II
Communications Reference
SGDV H, J SERVOPACK
SGDV-COA Converter
SGMVV Servomotor
MANUAL NO. SIEP S800000 90D
Outline
Panel Display and
Operation of Digital Operator
Wiring and Connection
Operation
Adjustments
Utility Functions (Fn )
Monitor Displays (Un )
Fully-closed Loop Control
Troubleshooting
Appendix
3
4
1
2
5
6
9
10
7
8
Copyright © 2012 YASKAWA ELECTRIC CORPORATION
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of Yaskawa. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because Yaskawa is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, Yaskawa assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication.
About this Manual
This manual describes information required for designing, testing, adjusting, and maintaining large-capacity models of servo systems in the Σ -V series.
Keep this manual in a location where it can be accessed for reference whenever required. Manuals outlined on the following page must also be used as required by the application.
Differences between Large-capacity
Σ
-
V
SERVOPACKs and Standard
Σ -V
SERVOPACKs
The differences between the large-capacity Σ -V SERVOPACKs and the standard Σ -V SERVOPACKs are described below. Equipment damage may occur if these items are used or set incorrectly.
• CN1 Connector
The number of pins on the CN1 connector is different on a large-capacity Σ -V SERVOPACK (50 pins) and a standard Σ -V SERVOPACK (26 pins).
If you are using both types of SERVOPACK, use the correct connector model numbers when ordering and the correct signal assignments.
• Factory Settings of Parameters
The factory settings of the following parameters are different: Pn50A.3, Pn50B.0, and Pn511.0.
Make sure that you consider any differences in the factory settings if you copy the parameters from a standard Σ -V SERVOPACK to a large-capacity Σ -V SERVOPACK.
For details, refer to 3.4.1 Input Signal Allocations .
• Monitor Displays
The monitor display digits are different for P-OT, N-OT, and /DEC.
Make sure you are reading the displays correctly when checking signal operation.
For details, refer to 7.3 Monitoring Input Signals .
Description of Technical Terms
The following table shows the meanings of terms used in this manual.
Term
Cursor
Servomotor
SERVOPACK
Converter
Servo Drive
Servo System
Servo ON
Servo OFF
Base Block (BB)
Servo Lock
Main Circuit Cable
Meaning
Input position indicated by Digital Operator
Σ -V large-capacity SGMVV servomotor
Σ -V large-capacity SGDVH, -
Σ -V large-capacity SGDV-COA converter
J servo amplifier
A set that includes a servomotor, a SERVOPACK, and a converter
A servo control system that includes the combination of a servo drive with a host controller and peripheral devices
Power to motor ON
Power to motor OFF
Power supply to motor is turned OFF by shutting off the base current to the power transistor in the SERVOPACK.
A state in which the motor is stopped and is in position loop with a position reference of 0.
Cables which connect to the main circuit terminals, including main circuit power supply cables, control power supply cables, servomotor main circuit cables, and others.
iii
iv
IMPORTANT Explanations
The following icon is displayed for explanations requiring special attention.
• Indicates important information that should be memorized, as well as precautions, such as alarm displays, that do not involve potential damage to equipment.
Notation Used in this Manual
• Notation for Reverse Signals
The names of reverse signals (i.e., ones that are valid when low) are written with a forward slash (/) before the signal name.
Notation Example
BK = /BK
• Notation for Parameters
The notation depends on whether the parameter requires a value setting (parameter for numeric settings) or requires the selection of a function (parameter for selecting functions).
• Parameters for Numeric Settings
Control methods for which the parameter applies.
Speed : Speed control Position : Position control Torque : Torque control
Emergency Stop Torque Speed Position Torque
Pn406
Setting Range
0 to 800
Parameter number
Indicates the setting range for the parameter.
Setting Unit
1%
Factory Setting
800
When Enabled
After change
Indicates the minimum setting unit for the parameter.
Indicates the parameter setting before shipment.
Indicates when a change to the parameter will be effective.
Classification
Setup
Indicates the parameter classification.
• Parameters for Selecting Functions
Pn002
Parameter n.
0
[Factory setting] n.
1
Meaning
Uses the absolute encoder as an absolute encoder.
Uses the absolute encoder as an incremental encoder.
Parameter number
The notation “n.
” indicates a parameter for selecting functions. Each corresponds to the setting value of that digit. The notation shown here means that the third digit is 1.
When Enabled Classification
After restart
This section explains the selections for the function.
Rotation
Setup
Notation Example
Digital Operator Display (Display Example for Pn002)
㨚㧜㧜㧜㧜
1st digit
2nd digit
3rd digit
4th digit
Notation
Digit Notation
Meaning
Pn002.0
Pn002.1
Pn002.2
Pn002.3
Indicates the value for the
1st digit of parameter Pn002.
Indicates the value for the
2nd digit of parameter Pn002.
Indicates the value for the
3rd digit of parameter Pn002.
Indicates the value for the
4th digit of parameter Pn002.
MECHA
Notation
Setting Notation
Meaning
Pn002.0 = x or n.
x
Indicates that the value for the
1st digit of parameter Pn002 is x.
Pn002.1 = x or n.
x
Indicates that the value for the
2nd digit of parameter Pn002 is x.
Pn002.2 = x or n.
x
Indicates that the value for the
3rd digit of parameter Pn002 is x.
Pn002.3 = x or n.x
Indicates that the value for the
4th digit of parameter Pn002 is x.
v
vi
Manuals Related to the
Σ -V
Large-Capacity Models
Refer to the following manuals as required.
Name
Large-Capacity Σ -V Series
Catalog
(No.: KAEP S800000 86)
Σ -V Series
User’s Manual
For Use with Large-Capacity
Models
Setup Rotational Motor
(No.: SIEP S800000 89)
Σ -V Series
User’s Manual
For Use with Large-Capacity
Models
Design and Maintenance
Rotational Motor
MECHATROLINKII
Communications
Reference
(This Manual)
Σ -V Series
User’s Manual
MECHATROLINKII
Commands
(No.: SIEP S800000 54)
Σ -V Series
User’s Manual
Operation of Digital Operator
(No.: SIEP S800000 55)
AC Servomotor
Safety Precautions
(No.: TOBP C230200 00)
AC SERVOPACK and
Converter Σ -V Series
Safety Precautions
For Use with Large-Capacity
Models
(No.: TOBP C710829 07)
Σ Series
Safety Precautions
Digital Operator
(No.: TOBP C730800 00)
Selecting
Models and
Peripheral
Devices
Ratings and
Specifications
System
Design
Panels and
Wiring
Trial
Operation
Trial
Operation and Servo
Adjustment
Maintenance and
Inspection
Trademarks
MECHATROLINK is a trademark of the MECHATROLINK Members Association.
Safety Information
The following conventions are used to indicate precautions in this manual. Failure to heed precautions provided in this manual can result in serious or possibly even fatal injury or damage to the products or to related equipment and systems.
WARNING
Indicates precautions that, if not heeded, could possibly result in loss of life or serious injury.
CAUTION
Indicates precautions that, if not heeded, could result in relatively serious or minor injury, damage to the product, or faulty operation.
In some situations, the precautions indicated could have serious consequences if not heeded.
PROHIBITED
Indicates prohibited actions that must not be performed. For example, this symbol would be used to indicate that fire is prohibited as follows:
MANDATORY
Indicates compulsory actions that must be performed. For example, this symbol would be used to indicate that grounding is compulsory as follows:
vii
viii
Safety Precautions
These safety precautions are very important. Read them before performing any procedures such as checking products on delivery, storage and transportation, installation, wiring, operation and inspection, or disposal. Be sure to always observe these precautions thoroughly.
WARNING
• Never touch any rotating motor parts while the motor is running.
Failure to observe this warning may result in injury.
• Before starting operation with a machine connected, make sure that an emergency stop can be applied at any time.
Failure to observe this warning may result in injury or damage to the product.
• Never touch the inside of the SERVOPACKs and the converters.
Failure to observe this warning may result in electric shock.
• Do not remove the front cover of the power supply terminals while the power is ON.
Failure to observe this warning may result in electric shock.
• Immediately after the power is turned OFF or after a voltage resistance test, do not touch terminals while the CHARGE lamp is ON. For details on the charging time of the main circuit’s capacitor, refer to 3.1.5 Discharging Time of the Main Circuit’s Capacitor .
Residual voltage may cause electric shock.
• Follow the procedures and instructions provided in this manual for trial operation.
Failure to do so may result not only in faulty operation and damage to equipment, but also in personal injury.
• The output range of the rotational serial data for the absolute position detecting system used for Σ -V largecapacity servo drives is different from that of earlier systems for 12-bit and 15-bit encoders. As a result, the infinite-length positioning system of the Σ servo drives must be changed for use with Σ -V large-capacity servo drives. Be sure to make the system modifications.
• The multi-turn limit value need not be changed except for special applications.
Changing it inappropriately or unintentionally can be dangerous.
• If the Multi-turn Limit Disagreement alarm occurs, check the setting of parameter Pn205 in the SERVOPACK to be sure that it is correct.
If Fn013 is executed when an incorrect value is set in Pn205, an incorrect value will be set in the encoder. The alarm will disappear even if an incorrect value is set, but incorrect positions will be detected, resulting in a dangerous situation where the machine will move to unexpected positions.
• Do not remove the front cover, cables, connectors, or optional items from the front of the SERVO-
PACK and the converter while the power is ON.
Failure to observe this warning may result in electric shock or damage to the product.
• Do not damage, press, exert excessive force on, or place heavy objects on the cables.
Failure to observe this warning may result in electric shock, stopping operation of the product, or fire.
• Do not modify the product.
Failure to observe this warning may result in injury, fire, or damage to the product.
• Provide an appropriate braking device on the machine side to ensure safety. The holding brake on a servomotor with a brake is not a braking device for ensuring safety.
Failure to observe this warning may result in injury.
• Do not come close to the machine immediately after resetting a momentary power loss. The machine may restart unexpectedly. Take appropriate measures to ensure safety against an unexpected restart.
Failure to observe this warning may result in injury.
• Do not wire the regenerative resistor unit incorrectly. Never short-circuit the B1 and B2 terminals.
Failure to observe this warning may result in fire or damage to the product.
• Connect the ground terminal according to local electrical codes (100 Ω or less for a SERVOPACK and a converter with a 200 V power supply. 10 Ω or less for a SERVOPACK and a converter with
400 V power supply).
Improper grounding may result in electric shock or fire.
WARNING
• Be sure to connect the servomotor’s built-in thermostat to the host controller or to the main circuit magnetic contactor’s operation circuit.
Failure to observe this warning may result in injury, fire, or damage to the product.
• Usage Example 1:
In this example, the output signal from the thermostat is received by the host controller if the thermostat is activated and the host controller turns OFF the servo.
Main circuit magnetic contactor
Main circuit power supply
SERVOPACK and converter
M
Thermostat
ENC
Servo OFF
Host controller
• Usage Example 2:
In this example, the main circuit magnetic contactor’s operation circuit is activated or the output signal from the thermostat is received by the host controller if the thermostat is activated and the main circuit magnetic contactor is turned OFF.
Main circuit magnetic contactor
Main circuit power supply
SERVOPACK and converter
M
Thermostat
ENC
Main circuit magnetic contactor
Host controller or main circuit magnetic contactor’s operation circuit
• Installation, disassembly, or repair must be performed only by authorized personnel.
Failure to observe this warning may result in electric shock or injury.
• The person who designs a system using the safety function (Hard Wire Baseblock function) must have full knowledge of the related safety standards and full understanding of the instructions in this manual.
Failure to observe this warning may result in injury or damage to the product.
ix
x
Storage and Transportation
CAUTION
• Do not store or install the product in the following locations.
Failure to observe this caution may result in fire, electric shock, or damage to the product.
• Locations subject to direct sunlight
• Locations subject to temperatures outside the range specified in the storage/installation temperature conditions
• Locations subject to humidity outside the range specified in the storage/installation humidity conditions
• Locations subject to condensation as the result of extreme changes in temperature
• Locations subject to corrosive or flammable gases
• Locations subject to dust, salts, or iron dust
• Locations subject to exposure to water, oil, or chemicals
• Locations subject to shock or vibration
• Do not hold the product by the cables, motor shaft, or terminal box while transporting it.
Failure to observe this caution may result in injury or malfunction.
• Do not place any load exceeding the limit specified on the packing box.
Failure to observe this caution may result in injury or malfunction.
• If disinfectants or insecticides must be used to treat packing materials such as wooden frames, pallets, or plywood, the packing materials must be treated before the product is packaged, and methods other than fumigation must be used.
Example: Heat treatment, where materials are kiln-dried to a core
temperature of 56 ° C for 30 minutes or more.
If the electronic products, which include stand-alone products and products installed in machines, are packed with fumigated wooden materials, the electrical components may be greatly damaged by the gases or fumes resulting from the fumigation process. In particular, disinfectants containing halogen, which includes chlorine, fluorine, bromine, or iodine can contribute to the erosion of the capacitors.
Installation
CAUTION
• Never use the product in an environment subject to water, corrosive gases, inflammable gases, or combustibles.
Failure to observe this caution may result in electric shock or fire.
• Do not step on or place a heavy object on the product.
Failure to observe this caution may result in injury or malfunction.
• Do not cover the inlet or outlet ports and prevent any foreign objects from entering the product.
Failure to observe this caution may cause internal elements to deteriorate resulting in malfunction or fire.
• Be sure to install the product in the correct direction.
Failure to observe this caution may result in malfunction.
• Provide the specified clearances between the SERVOPACK and the converter and the control panel or with other devices.
Failure to observe this caution may result in fire or malfunction.
• Do not apply any strong impact.
Failure to observe this caution may result in malfunction.
Wiring
CAUTION
• Be sure to wire correctly and securely.
Failure to observe this caution may result in motor overrun, injury, or malfunction.
• Do not connect a commercial power supply to the U, V, or W terminals for the servomotor connection.
Failure to observe this caution may result in injury or fire.
• Securely connect the main circuit terminals.
Failure to observe this caution may result in fire.
• Do not bundle or run the main circuit cables together with the I/O signal cables or the encoder cables in the same duct. Keep them separated by at least 30 cm.
Failure to do so may result in malfunction.
• Use shielded twisted-pair wires or multi-core shielded twisted-pair wires for I/O signal cables and encoder cables.
• Use the bus bars that are included with the converter, and connect the P and N terminals on the
SERVOPACK and converter securely.
• The maximum cable length is 3 m for I/O signal cables, 50 m for connection cables for servomotor main circuit or encoder cables, and 10 m for control power supply cables to 400-V converters (+24
V, 0 V).
• Do not touch the power terminals while discharging the main circuit’s capacitor, because high voltage may still remain in the SERVOPACK and the converter. For details on the charging time of the main circuit’s capacitor, refer to 3.1.5 Discharging Time of the Main Circuit’s Capacitor .
Before starting to do wiring or inspections, confirm that the power has been completely discharged (charge indicator: OFF) by using a tester to measure the voltage between the P and N terminals for DC power.
• Be sure to observe the following precautions when wiring the main circuit’s terminals and connectors on a SERVOPACK or converter.
• Do not turn ON the power to a SERVOPACK or converter until all wiring, including the wiring to the main circuit terminals, has been completed.
• Remove detachable main circuit terminals from the SERVOPACK and the converter prior to wiring.
• Insert only one power line per opening in the main circuit terminals.
• Make sure that no part of the core wire comes into contact with (i.e., short-circuits) adjacent wires.
• Install a battery at either the host controller or the battery unit of the encoder, but not both.
It is dangerous to install batteries at both ends simultaneously, because that sets up a loop circuit between the batteries.
• Always use the specified power supply voltage.
An incorrect voltage may result in fire or malfunction.
• Make sure that the polarity is correct.
Incorrect polarity may cause ruptures or damage.
• Take appropriate measures to ensure that the input power supply is supplied within the specified voltage fluctuation range. Be particularly careful in places where the power supply is unstable.
An incorrect power supply may result in damage to the product.
• Install external breakers or other safety devices against short-circuiting in external wiring.
Failure to observe this caution may result in fire.
• Take appropriate and sufficient countermeasures for each form of potential interference when installing systems in the following locations.
• Locations subject to static electricity or other forms of noise
• Locations subject to strong electromagnetic fields and magnetic fields
• Locations subject to possible exposure to radioactivity
• Locations close to power supplies
Failure to observe this caution may result in damage to the product.
• Do not reverse the polarity of the battery when connecting it.
Failure to observe this caution may damage the battery, the SERVOPACK, or servomotor, or cause an explosion.
• Wiring or inspection must be performed by a technical expert.
• Use a 24-VDC power supply for the control power of 400-V converter with double insulation or reinforced insulation.
xi
xii
Operation
CAUTION
• Always use the servomotor, the SERVOPACK, and the converter in one of the specified combinations.
Failure to observe this caution may result in fire or malfunction.
• Conduct trial operations on the servomotor alone, with the motor shaft disconnected from the machine to avoid accidents.
Failure to observe this caution may result in injury.
• During trial operation, confirm that the holding brake works correctly. Furthermore, secure system safety against problems such as signal line disconnection.
Failure to observe this caution may result in injury or damage to the product.
• Before starting operation with a machine connected, change the settings to match the parameters of the machine.
Starting operation without matching the proper settings may cause the machine to run out of control or malfunction.
• Do not frequently turn power ON and OFF.
• Frequently turning power ON and OFF causes elements inside the SERVOPACK and the converter to deteriorate. Do not use the servo drive with an application that requires frequently turning power ON and
OFF.
• After the actual operation starts, the allowable interval for turning power ON and OFF is one hour or longer.
• When using JOG operations (Fn002) origin search operations (Fn003), or EasyFFT operations
(Fn206), the dynamic brake function does not work for reverse overtravel or forward overtravel.
Take necessary precautions.
Failure to observe this caution may result in damage to the product.
• When using the servomotor for a vertical axis, install safety devices to prevent workpieces from falling due to alarms or overtravels. Set the servomotor so that it will stop in the zero clamp state when overtravel occurs.
Failure to observe this caution may cause workpieces to fall due to overtravel.
• When not using tuning-less function, set to the correct moment of inertia ratio (Pn103).
Setting to an incorrect moment of inertia ratio may cause vibration.
• Do not touch the SERVOPACK and the converter heatsinks, regenerative resistor, or servomotor while power is ON or soon after the power is turned OFF.
Failure to observe this caution may result in burns due to high temperatures.
• Do not make any extreme adjustments or setting changes of parameters.
Failure to observe this caution may result in injury or damage to the product due to unstable operation.
• When an alarm occurs, remove the cause, reset the alarm after confirming safety, and then resume operation.
Failure to observe this caution may result in damage to the product, fire, or injury.
• Do not use the holding brake of the servomotor for braking.
Failure to observe this caution may result in malfunction.
• An alarm or warning may occur if communications are performed with the host controller while the
SigmaWin+ or Digital Operator is operating.
If an alarm or warning occurs, it may stop the current process and stop the system.
Maintenance and Inspection
CAUTION
• Do not disassemble the SERVOPACK and the converter.
Failure to observe this caution may result in electric shock or injury.
• Do not attempt to change wiring while the power is ON.
Failure to observe this caution may result in electric shock or injury.
• When replacing the SERVOPACK, resume operation only after copying the previous SERVOPACK parameters to the new SERVOPACK.
Failure to observe this caution may result in damage to the product.
• Be sure to eliminate static electricity before operating buttons and switches inside the plastic cover.
Failure to observe this caution may result in damage to the product.
Disposal
CAUTION
• When disposing of the products, treat them as ordinary industrial waste.
General Precautions
Observe the following general precautions to ensure safe application.
• The products shown in illustrations in this manual are sometimes shown without covers or protective guards.
Always replace the cover or protective guard as specified first, and then operate the products in accordance with the manual.
• The drawings presented in this manual are typical examples and may not match the product you received.
• If the manual must be ordered due to loss or damage, inform your nearest Yaskawa representative or one of the offices listed on the back of this manual.
xiii
xiv
Warranty
(1) Details of Warranty
Warranty Period
The warranty period for a product that was purchased (hereinafter called “delivered product”) is one year from the time of delivery to the location specified by the customer or 18 months from the time of shipment from the
Yaskawa factory, whichever is sooner.
Warranty Scope
Yaskawa shall replace or repair a defective product free of charge if a defect attributable to Yaskawa occurs during the warranty period above. This warranty does not cover defects caused by the delivered product reaching the end of its service life and replacement of parts that require replacement or that have a limited service life.
This warranty does not cover failures that result from any of the following causes.
1. Improper handling, abuse, or use in unsuitable conditions or in environments not described in product catalogs or manuals, or in any separately agreed-upon specifications
2. Causes not attributable to the delivered product itself
3. Modifications or repairs not performed by Yaskawa
4. Abuse of the delivered product in a manner in which it was not originally intended
5. Causes that were not foreseeable with the scientific and technological understanding at the time of shipment from Yaskawa
6. Events for which Yaskawa is not responsible, such as natural or human-made disasters
(2) Limitations of Liability
1. Yaskawa shall in no event be responsible for any damage or loss of opportunity to the customer that arises due to failure of the delivered product.
2. Yaskawa shall not be responsible for any programs (including parameter settings) or the results of program execution of the programs provided by the user or by a third party for use with programmable Yaskawa products.
3. The information described in product catalogs or manuals is provided for the purpose of the customer purchasing the appropriate product for the intended application. The use thereof does not guarantee that there are no infringements of intellectual property rights or other proprietary rights of Yaskawa or third parties, nor does it construe a license.
4. Yaskawa shall not be responsible for any damage arising from infringements of intellectual property rights or other proprietary rights of third parties as a result of using the information described in catalogs or manuals.
(3) Suitability for Use
1. It is the customer’s responsibility to confirm conformity with any standards, codes, or regulations that apply if the Yaskawa product is used in combination with any other products.
2. The customer must confirm that the Yaskawa product is suitable for the systems, machines, and equipment used by the customer.
3. Consult with Yaskawa to determine whether use in the following applications is acceptable. If use in the application is acceptable, use the product with extra allowance in ratings and specifications, and provide safety measures to minimize hazards in the event of failure.
• Outdoor use, use involving potential chemical contamination or electrical interference, or use in conditions or environments not described in product catalogs or manuals
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, vehicle systems, medical equipment, amusement machines, and installations subject to separate industry or government regulations
• Systems, machines, and equipment that may present a risk to life or property
• Systems that require a high degree of reliability, such as systems that supply gas, water, or electricity, or systems that operate continuously 24 hours a day
• Other systems that require a similar high degree of safety
4. Never use the product for an application involving serious risk to life or property without first ensuring that the system is designed to secure the required level of safety with risk warnings and redundancy, and that the
Yaskawa product is properly rated and installed.
5. The circuit examples and other application examples described in product catalogs and manuals are for reference. Check the functionality and safety of the actual devices and equipment to be used before using the product.
6. Read and understand all use prohibitions and precautions, and operate the Yaskawa product correctly to prevent accidental harm to third parties.
(4) Specifications Change
The names, specifications, appearance, and accessories of products in product catalogs and manuals may be changed at any time based on improvements and other reasons. The next editions of the revised catalogs or manuals will be published with updated code numbers. Consult with your Yaskawa representative to confirm the actual specifications before purchasing a product.
xv
xvi
Harmonized Standards
North American Safety Standards (UL)
Name (Model)
UL Standards
(UL File No.)
-
SERVOPACK (SGDV-
J),
Converter (SGDV-COA)
H,
UL508C (E147823)
Servomotor (SGMVV)
European Directives
UL1004 (E165827)
Mark Remarks
Application pending.
Certified.
Name (Model)
-
SERVOPACK (SGDV-
J),
Converter (SGDV-COA)
Servomotor (SGMVV)
H,
European Directives
Machinery Directive
2006/42/EC
EMC Directive
2004/108/EC
Low Voltage Directive
2006/95/EC
EMC Directive
2004/108/EC
Low Voltage Directive
2006/95/EC
Harmonized Standards
EN ISO13849-1: 2008,
EN 954-1
EN 55011 group 1 class A,
EN 61000-6-2,
EN 61800-3
EN 50178,
EN 61800-5-1
EN 55011 group 1 class A,
EN 61000-6-2,
EN 61800-3
EN 60034-1,
EN 60034-5/A1
Remarks
Application pending.
Safety Standards
Name (Model) Safety Standards
Safety of Machinery
-
SERVOPACK (SGDV-
J),
Converter (SGDV-COA)
H,
Functional Safety
EMC
Safe Performance
Items
Safety Integrity Level
Probability of Dangerous Failure per Hour
Category
Performance Level
Mean Time to Dangerous Failure of Each
Channel
Average Diagnostic Coverage
Stop Category
Safety Function
Proof test Interval
Standards
EN ISO13849-1: 2008,
EN 954-1,
IEC 60204-1
IEC 61508 series,
IEC 62061,
IEC 61800-5-2
IEC 61326-3-1
Standards
IEC 61508
IEC 62061
IEC 61508,
IEC 62061
EN 954-1
EN ISO 13849-1
EN ISO 13849-1
EN ISO 13849-1
IEC 60204-1
IEC 61800-5-2
IEC 61508
Remarks
Application pending.
Performance Level
SIL2
SILCL2
PFH ⇐ 1.7
× 10
-9
(0.17% of SIL2)
[1/h]
Category 3
PL d (Category 3)
MTTFd: High
DCave: Low
Stop category 0
STO
10 years
xvii
xviii
Contents
About this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Safety Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv
Harmonized Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvi
Chapter 1 Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
1.1 Σ -V Large-Capacity SERVOPACKs and Converters . . . . . . . . . . . . . . . . . . . 1-2
1.2 SERVOPACK Part Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1.3 Converter Part Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
1.4 Ratings and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
1.4.1 Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
1.4.2 Basic Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
1.4.3 MECHATROLINKII Function Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
1.5 SERVOPACK and Converter Internal Block Diagrams . . . . . . . . . . . . . . . . 1-10
1.5.1 Three-phase 200 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
1.5.2 Three-phase 400 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11
1.6 Examples of Servo System Configurations . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
1.7 SERVOPACK Model Designation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13
1.8 Converter Model Designation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14
1.9 Combinations of Servomotors, SERVOPACKs, and Converters . . . . . . . . . 1-15
1.10 Inspection and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-16
Chapter 2 Panel Display and Operation of Digital Operator . . . . . . . . . . . .2-1
2.1 Panel Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.1 Status Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.2 Alarm and Warning Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.3 Hard Wire Base Block Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.4 Overtravel Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.2 Operation of Digital Operator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.3 Utility Functions (Fn ). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
2.4 Parameters (Pn ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2.4.1 Parameter Classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2.4.2 Notation for Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2.4.3 Setting Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
2.5 Monitor Displays (Un ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
Chapter 3 Wiring and Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
3.1 Main Circuit Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
3.1.1 Main Circuit Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
3.1.2 Main Circuit Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
3.1.3 Typical Main Circuit Wiring Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14
3.1.4 General Precautions for Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18
3.1.5 Discharging Time of the Main Circuit’s Capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-20
3.2 Connecting the Converter to the SERVOPACK . . . . . . . . . . . . . . . . . . . . . . 3-21
3.2.1 Connecting the Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-21
3.2.2 Interconnecting Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-21
3.3 I/O Signal Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23
3.3.1 I/O Signal (CN1) Names and Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23
3.3.2 Safety Function Signal (CN8) Names and Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-24
3.3.3 Example of I/O Signal Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-25
3.4 I/O Signal Allocations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-26
3.4.1 Input Signal Allocations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-26
3.4.2 Output Signal Allocations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-27
3.5 Examples of Connection to Host Controller . . . . . . . . . . . . . . . . . . . . . . . . . 3-29
3.5.1 Sequence Input Circuit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-29
3.5.2 Sequence Output Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-31
3.6 Wiring MECHATROLINKII Communications . . . . . . . . . . . . . . . . . . . . . . . 3-33
3.7 Encoder Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-34
3.7.1 Encoder Signal (CN2) Names and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-34
3.7.2 Encoder Connection Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-34
3.8 Selecting and Connecting a Regenerative Resistor Unit . . . . . . . . . . . . . . . 3-36
3.8.1 Selecting a Regenerative Resistor Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-36
3.8.2 Connecting a Regenerative Resistor Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-37
3.8.3 Setting Regenerative Resistor Capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-38
3.8.4 Installation Standards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-39
3.9 Selecting and Connecting a Dynamic Brake Unit . . . . . . . . . . . . . . . . . . . . 3-40
3.9.1 Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-40
3.9.2 Selecting the Cable for the Dynamic Brake Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-40
3.9.3 Setting the Dynamic Brake Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-41
3.9.4 Setting the Dynamic Brake Answer Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-42
3.9.5 Installation Standards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-43
3.9.6 Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-43
3.10 Noise Control and Measures for Harmonic Suppression. . . . . . . . . . . . . . 3-46
3.10.1 Wiring for Noise Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-46
3.10.2 Precautions on Connecting Noise Filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-48
3.10.3 Connecting a Reactor for Harmonic Suppression . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-50
Chapter 4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1
4.1 MECHATROLINKII Communications Settings . . . . . . . . . . . . . . . . . . . . . . . 4-3
4.1.1 Setting Switches S2 and S3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
4.2 MECHATROLINKII Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
4.3 Basic Functions Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
4.3.1 Servomotor Rotation Direction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
4.3.2 Overtravel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
4.3.3 Software Limit Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
4.3.4 Holding Brakes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11
4.3.5 Stopping Servomotors after SV_OFF Command or Alarm Occurrence. . . . . . . . . . . . . . 4-16
4.3.6 Instantaneous Power Interruption Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-18
4.3.7 SEMI F47 Function (Torque Limit Function for Low DC Power Supply Voltage for
Main Circuit). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-19
4.3.8 Setting Motor Overload Detection Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-22
4.4 Trial Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24
4.4.1 Inspection and Checking before Trial Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24
4.4.2 Trial Operation via MECHATROLINKII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-25
4.4.3 Electronic Gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-26
4.4.4 Encoder Output Pulses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-29
4.4.5 Setting Encoder Output Pulse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-30
4.5 Test Without Motor Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-31
4.5.1 Motor Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-31
4.5.2 Motor Position and Speed Responses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-32
4.5.3 Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-33
4.5.4 Digital Operator Displays during Testing without Motor . . . . . . . . . . . . . . . . . . . . . . . . . . 4-34
4.6 Limiting Torque. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-35
4.6.1 Internal Torque Limit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-35
4.6.2 External Torque Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-36
4.6.3 Checking Output Torque Limiting during Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-37
xix
xx
4.7 Absolute Encoders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-38
4.7.1 Connecting the Absolute Encoder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-39
4.7.2 Absolute Data Request (SENS ON Command) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-41
4.7.3 Battery Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-42
4.7.4 Absolute Encoder Setup and Reinitialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-44
4.7.5 Absolute Data Reception Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-46
4.7.6 Multiturn Limit Setting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-50
4.7.7 Multiturn Limit Disagreement Alarm (A.CC0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-51
4.7.8 Absolute Encoder Origin Offset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-52
4.8 Other Output Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-53
4.8.1 Servo Alarm Output Signal (ALM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-53
4.8.2 Warning Output Signal (/WARN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-53
4.8.3 Rotation Detection Output Signal (/TGON) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-54
4.8.4 Servo Ready Output Signal (/S-RDY) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-54
4.8.5 Speed Coincidence Output Signal (/V-CMP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-55
4.8.6 Positioning Completed Output Signal (/COIN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-56
4.8.7 Positioning Near Output Signal (/NEAR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-57
4.8.8 Speed Limit Detection Signal (/VLT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-58
4.9 Safety Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-60
4.9.1 Hard Wire Base Block (HWBB) Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-60
4.9.2 External Device Monitor (EDM1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-66
4.9.3 Application Example of Safety Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-68
4.9.4 Confirming Safety Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-69
4.9.5 Connecting a Safety Function Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-69
4.9.6 Precautions for Safety Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-70
Chapter 5 Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-1
5.1 Type of Adjustments and Basic Adjustment Procedure . . . . . . . . . . . . . . . . . 5-3
5.1.1 Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
5.1.2 Basic Adjustment Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4
5.1.3 Monitoring Operation during Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5
5.1.4 Safety Precautions on Adjustment of Servo Gains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-8
5.2 Tuning-less Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11
5.2.1 Tuning-less Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11
5.2.2 Tuning-less Levels Setting (Fn200) Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-14
5.2.3 Related Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17
5.3 Advanced Autotuning (Fn201) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18
5.3.1 Advanced Autotuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18
5.3.2 Advanced Autotuning Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-21
5.3.3 Related Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-27
5.4 Advanced Autotuning by Reference (Fn202) . . . . . . . . . . . . . . . . . . . . . . . . 5-28
5.4.1 Advanced Autotuning by Reference. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-28
5.4.2 Advanced Autotuning by Reference Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-30
5.4.3 Related Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-34
5.5 One-parameter Tuning (Fn203) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-35
5.5.1 One-parameter Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-35
5.5.2 One-parameter Tuning Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-36
5.5.3 One-parameter Tuning Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-43
5.5.4 Related Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-44
5.6 Anti-Resonance Control Adjustment Function (Fn204) . . . . . . . . . . . . . . . . 5-45
5.6.1 Anti-Resonance Control Adjustment Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-45
5.6.2 Anti-Resonance Control Adjustment Function Operating Procedure. . . . . . . . . . . . . . . . 5-46
5.6.3 Related Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-51
5.7 Vibration Suppression Function (Fn205) . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-52
5.7.1 Vibration Suppression Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-52
5.7.2 Vibration Suppression Function Operating Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . 5-53
5.7.3 Related Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-56
5.8 Additional Adjustment Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-57
5.8.1 Switching Gain Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-57
5.8.2 Manual Adjustment of Friction Compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-61
5.8.3 Current Control Mode Selection Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-63
5.8.4 Current Gain Level Setting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-63
5.8.5 Speed Detection Method Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-63
5.8.6 Backlash Compensation Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-64
5.8.7 Position Integral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-70
5.9 Compatible Adjustment Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-71
5.9.1 Feedforward Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-71
5.9.2 Mode Switch (P/PI Switching) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-72
5.9.3 Torque Reference Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-74
Chapter 6 Utility Functions (Fn ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-1
6.1 List of Utility Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
6.2 Alarm History Display (Fn000) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
6.3 JOG Operation (Fn002) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
6.4 Origin Search (Fn003) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
6.5 Program JOG Operation (Fn004) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8
6.6 Initializing Parameter Settings (Fn005) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-12
6.7 Clearing Alarm History (Fn006) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-13
6.8 Offset Adjustment of Analog Monitor Output (Fn00C) . . . . . . . . . . . . . . . . . 6-14
6.9 Gain Adjustment of Analog Monitor Output (Fn00D) . . . . . . . . . . . . . . . . . . 6-16
6.10 Automatic Offset-Signal Adjustment of the Motor Current Detection
Signal (Fn00E). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-18
6.11 Manual Offset-Signal Adjustment of the Motor Current Detection
Signal (Fn00F). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-19
6.12 Write Prohibited Setting (Fn010) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-21
6.13 Servomotor Model Display (Fn011) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-23
6.14 Software Version Display (Fn012) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-24
6.15 Resetting Configuration Errors in Option Modules (Fn014) . . . . . . . . . . . . 6-25
6.16 Vibration Detection Level Initialization (Fn01B) . . . . . . . . . . . . . . . . . . . . . 6-26
6.17 Display of SERVOPACK and Servomotor ID (Fn01E) . . . . . . . . . . . . . . . . 6-28
6.18 Display of Servomotor ID in Feedback Option Module (Fn01F) . . . . . . . . 6-30
6.19 Origin Setting (Fn020) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-31
6.20 Software Reset (Fn030). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-32
6.21 EasyFFT (Fn206). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-33
6.22 Online Vibration Monitor (Fn207). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-37
Chapter 7 Monitor Displays (Un ) . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-1
7.1 List of Monitor Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
7.2 Viewing Monitor Displays. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3
7.3 Monitoring Input Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4
7.3.1 Interpreting Input Signal Display Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4
7.3.2 Input Signal Display Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-5
7.4 Monitoring Output Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6
7.4.1 Interpreting Output Signal Display Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6
7.4.2 Output Signal Display Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6
7.5 Monitoring Safety Input Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7
7.5.1 Interpreting Safety Input Signal Display Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7
7.5.2 Safety Input Signal Display Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7
xxi
xxii
Chapter 8 Fully-closed Loop Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-1
8.1 System Configuration and Connection Example for SERVOPACK with Fully-closed Loop Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
8.1.1 System Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
8.1.2 Internal Block Diagram of Fully-closed Loop Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3
8.1.3 Serial Converter Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-4
8.1.4 Example of Connections to External Encoders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6
8.1.5 Encoder Output Pulse Signals from SERVOPACK with an External Encoder by
Renishaw plc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-7
8.1.6 Precautions When Using an External Incremental Encoder by Magnescale . . . . . . . . . . . 8-8
8.2 SERVOPACK and Converter Startup Procedure . . . . . . . . . . . . . . . . . . . . . 8-12
8.3 Parameter Settings for Fully-closed Loop Control . . . . . . . . . . . . . . . . . . . . 8-14
8.3.1 Motor Rotation Direction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-15
8.3.2 Sine Wave Pitch (Frequency) for an External Encoder . . . . . . . . . . . . . . . . . . . . . . . . . . 8-17
8.3.3 Setting Encoder Output Pulses (PAO, PBO, and PCO). . . . . . . . . . . . . . . . . . . . . . . . . . 8-17
8.3.4 External Absolute Encoder Data Reception Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . 8-18
8.3.5 Electronic Gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-21
8.3.6 Alarm Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-22
8.3.7 Analog Monitor Signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-23
8.3.8 Speed Feedback Method during Fully-closed Loop Control . . . . . . . . . . . . . . . . . . . . . . 8-23
Chapter 9 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-1
9.1 Alarm Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2
9.1.1 List of Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2
9.1.2 Troubleshooting of Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-6
9.2 Warning Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-22
9.2.1 List of Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-22
9.2.2 Troubleshooting of Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-23
9.3 Monitoring Communication Data on Occurrence of an Alarm or Warning . . 9-27
9.4 Troubleshooting Malfunction Based on Operation and Conditions of the Servomotor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-28
Chapter 10 Appendix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-1
10.1 List of Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-2
10.1.1 Utility Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-2
10.1.2 Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-3
10.2 List of Monitor Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-34
10.3 Parameter Recording Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-35
Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Index-1
Revision History
1
Outline
1.1 Σ -V Large-Capacity SERVOPACKs and Converters . . . . . . . . . . . . . . . . . 1-2
1.2 SERVOPACK Part Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1.3 Converter Part Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
1.4 Ratings and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
1.4.1 Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
1.4.2 Basic Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
1.4.3 MECHATROLINKII Function Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
1.5 SERVOPACK and Converter Internal Block Diagrams . . . . . . . . . . . . . . 1-10
1.5.1 Three-phase 200 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
1.5.2 Three-phase 400 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11
1.6 Examples of Servo System Configurations . . . . . . . . . . . . . . . . . . . . . . . 1-12
1.7 SERVOPACK Model Designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13
1.8 Converter Model Designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14
1.9 Combinations of Servomotors, SERVOPACKs, and Converters . . . . . . . 1-15
1.10 Inspection and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-16
1
1-1
1 Outline
1.1
Σ
-V
Large-Capacity SERVOPACKs and Converters
The Σ -V large-capacity SERVOPACKs and converters are designed for applications that require frequent high-speed, high-precision positioning. The SERVOPACKs and converters make the most of machine performance in the shortest time possible, therefore contributing to improving productivity.
1.2
SERVOPACK Part Names
This section describes the part names of SERVOPACKs.
Use a SERVOPACK together with a converter. For details, refer to 1.9 Combinations of Servomotors, SER-
VOPACKs, and Converters.
Note: For the purpose of this description, the SERVOPACK is shown with the front cover removed. Always keep the front cover attached when using the SERVOPACK.
With plastic cover open
1-2
M-II
No.
Name
DIP switch (S3)
Rotary switch (S2)
Power LED indicator
(POWER)
CN5 Analog monitor connector
Panel display
Nameplate
Input voltage
Description
Used to set MECHATROLINK-II communications.
Used to set the MECHATROLINK-II station address.
Indicates that the control power is being supplied
(green).
Used to monitor motor speed, torque reference, and other values through a special cable (option).
Indicates the servo status with a seven-segment
LED display.
Indicates the SERVOPACK model and ratings.
Located on the side of the SERVOPACK.
–
Reference
4.1.1 Setting Switches S2 and S3
4.1.1 Setting Switches S2 and S3
–
5.1.3 Monitoring Operation during Adjustment
2.1.1 Status Display
–
–
1.2 SERVOPACK Part Names
No.
Name
SERVOPACK model
Description
Indicates the model number of the SERVOPACK.
Reference
1.7 SERVOPACK Model
Designation
–
(cont’d)
Serial number
Dynamic brake unit connector (CN115)
Control power input connectors
(CN103 and CN104)
SERVOPACK-converter I/O connector (CN901)
–
Used for ON/OFF control of the magnetic contactor in the dynamic brake unit. Connect this connector to terminals DBON and DB24 on the dynamic brake unit.
Used to input 24 VDC ( ±15% necessary to connect CN104.
). CN103 and
CN104 are equivalent inputs. It is normally not
–
Connect this connector to CN901 on the converter. –
Charge indicator
Main circuit DC voltage input terminals (P and N)
Dynamic brake unit connection terminals
(DU, DV, and DW)
Ground terminal
Plunger
Lights (orange) when the main circuit power supply is ON and stays lit as long as the internal capacitor remains charged. Therefore, do not touch the SERVOPACK even after the power supply is turned OFF if the indicator is lit. It may result in electric shock.
Connect these terminals to P and N on the converter.
Use these terminals to connect the dynamic brake unit.
Do not connect servomotors to these terminals.
Be sure to connect to protect against electrical shock.
Pull it to open the plastic cover for use of the
MECHATROLINK-II communications switch and other components.
–
–
–
–
3.1 Main Circuit Wiring
–
CN3 Connector for digital operator
Connects a digital operator (option, JUSP-OP05A-
1-E) or a personal computer (RS422).
Σ -V Series User's Manual
Operation of Digital Operator (No.: SIEP S800000 55).
Communications LED indicator (COM)
CN7 Connector for personal computer
Lights (green) during communications between the SERVOPACK and the MECHATROLINK system.
A USB connector for use with a personal computer. Use the connection cable (JZSP-CVS06-02-
E).
–
–
MECHATROLINKII communications connectors
(CN6A, CN6B)
CN1 I/O signal connector
Connects MECHATROLINK-II -supported devices.
3.6 Wiring MECHA-
TROLINK-II Communications
3.3 I/O Signal Connections
CN8 Connector for safety function devices
CN2 Encoder connector
+, - terminals
Servomotor terminals
(U, V, W)
Used for sequence I/O signals.
Connects a safety function device.
Note: When not using the safety function, use the
SERVOPACK with the safety function’s jumper connector (provided as an accessory) inserted.
Connects the encoder in the servomotor.
Do not connect anything to these terminals.
Connects the main circuit cable (power line) for servomotor.
3.3.2 Safety Function Signal
(CN8) Names and Functions
4.9 Safety Function
3.7 Encoder Connection
–
3.1 Main Circuit Wiring
1
1-3
1 Outline
1.3
Converter Part Names
This section describes the parts of a converter.
Use a converter together with a SERVOPACK. For details, refer to 1.9 Combinations of Servomotors, SER-
VOPACKs, and Converters .
Note: For the purpose of this description, the SERVOPACK is shown with the front cover removed. Always keep the front cover attached when using the SERVOPACK.
Converter
SGDV-COA2BAA
SGDV-COA3ZDA
Converter
SGDV-COA3GAA
SGDV-COA5EDA
1-4
No.
Nameplate
Name Description
Indicates the converter model and ratings. Located on the side of the converter.
–
Reference
Control power input connector (CN101)
Used to connect the control power input.
3.1 Main Circuit Wiring
Control power output connectors
(CN103 and CN104)
These connectors output 24 VDC to the SERVO-
PACK. For a 400-V system, the 24-VDC (±15%) input is output unaltered from CN103. CN103 and
CN104 are equivalent outputs. It is normally not necessary to connect CN104.
–
SERVOPACK-converter I/O connector (CN901)
Connect this connector to CN901 on the converter. –
Charge indicator
DC reactor terminals for harmonic suppression
( 1 and 2)
Main circuit power supply terminals (L1, L2, and L3)
Lights (orange) when the main circuit power supply is ON and stays lit as long as the internal capacitor remains charged. Therefore, do not touch the SERVOPACK even after the power supply is turned OFF if the indicator is lit. It may result in electric shock.
–
Connects a DC reactor for harmonic suppression.
3.10.3 Connecting a Reactor for Harmonic Suppression
Used for main circuit power supply input.
3.1 Main Circuit Wiring
Ground terminals
Input voltage
Converter model
Be sure to connect to protect against electrical shock.
–
Indicates the model number of the converter.
3.1 Main Circuit Wiring
–
–
1.3 Converter Part Names
No.
Name
Serial number
Converter LED indicator
(C-RDY)
Converter LED indicator
(OVERHEAT)
Converter LED indicator
(CHRG-ERR)
Converter LED indicator
(FANSTOP)
Converter LED indicator
(MC-FAULT)
Main circuit DC voltage output terminals (P and N)
Regenerative resistor connecting terminals
(B1 and B2)
Description Reference
(cont’d)
– –
Lights (green) when the converter is ready to be used for operations.
Lights (red) when the converter’s heat sink is overheated.
Lights (red) when the voltage between the main circuit’s DC voltage output terminals P and N is abnormal.
Lights (red) when an error occurs while the converter fan is running.
Lights (red) when an error occurs when the inrush current limit relay is used.
Connect these terminals to P and N on the SER-
VOPACK.
–
–
–
–
–
–
Connects external regenerative resistors.
3.8 Selecting and Connecting a Regenerative Resistor
Unit
1
1-5
1-6
1 Outline
1.4.1 Ratings
1.4
Ratings and Specifications
This section describes the ratings and specifications of SERVOPACKs and converters.
1.4.1
Ratings
Ratings of SERVOPACKs and converters are as shown below.
Three-phase 200 VAC
SERVOPACK Model SGDV-
Converter Model SGDV-COA
Continuous Output Current [Arms]
Instantaneous Max. Output Current [Arms]
Regenerative Resistor Unit
*
Main Circuit Power Supply
Control Power Supply
Overvoltage Category
121H
2BAA
161H
3GAA
116
240
160
340
External
Three-phase 200 to 230 VAC, +10% to -15%, 50/60 Hz
200
460
Single-phase 200 to 230 VAC, +10% to -15%, 50/60 Hz
III
201H
3GAA
∗ Refer to 3.8 Selecting and Connecting a Regenerative Resistor Unit for details.
Three-phase 400 VAC
SERVOPACK Model
Converter Model
SGDV-
SGDV-COA
Continuous Output Current [Arms]
Instantaneous Max. Output Current [Arms]
Regenerative Resistor Unit
*
Main Circuit Power Supply
Control Power Supply
Overvoltage Category
750J
3ZDA
75
170
∗ Refer to 3.8 Selecting and Connecting a Regenerative Resistor Unit for details.
101J
5EDA
98
230
External
Three-phase 380 to 480 VAC, +10% to -15%, 50/60 Hz
24 VDC, ± 15%
III
131J
5EDA
130
340
1.4 Ratings and Specifications
1.4.2
Basic Specifications
Basic specifications of SERVOPACKs and converters are shown below.
Drive Method
Feedback
Surrounding Air Temperature
Storage Temperature
Ambient Humidity
Storage Humidity
Vibration Resistance
Operating
Conditions
Shock Resistance
Sine-wave current drive with PWM control of IGBT
Encoder: 20-bit (incremental, absolute)
0 ° C to +55 ° C
-20 ° C to +85 ° C
90% RH or less
90% RH or less
4.9 m/s
2
19.6 m/s
2
With no freezing or condensation
Protection Class
Pollution Degree
IP10
2
An environment that satisfies the following conditions.
• Free of corrosive or flammable gases
• Free of exposure to water, oil, or chemicals
• Free of dust, salts, or iron dust
Mounting
Performance
Altitude
Others
Harmonized Standards
(Application pending)
1000 m or less
Free of static electricity, strong electromagnetic fields, magnetic fields or exposure to radioactivity
UL508C
EN 50178, EN 55011 group 1 class A, EN 61000-6-2, EN 1800-3,
EN 61800-5-1, EN 954-1, IEC 61508-1 to 4
Standard: Base-mounted
Optional: Duct-ventilated
Speed Control Range
1:5000 (The lower limit of the speed control range must be lower than the point at which the rated torque does not cause the servomotor to stop.)
Speed
Regulation
*1
Load
Regulation
Voltage
Regulation
0% to 100% load:
Rated voltage ±
± 0.01% max. (at rated speed)
10%: 0% (at rated speed)
Temperature
Regulation
25 ± 25 ° C: ± 0.1% max. (at rated speed)
Torque Control
Tolerance
(Repeatability)
± 1%
Soft Start Time
Setting *2
0 to 10 s (Can be set individually for acceleration and deceleration.)
1
1-7
1-8
1 Outline
1.4.2 Basic Specifications
(cont’d)
Encoder Output Pulse
Sequence
Input
Input
Signals which can be allocated
Phase A, B, C: line driver
Encoder output pulse: any setting ratio (Refer to 4.4.5
.)
Number of
Channels
7 ch
Functions
• Homing deceleration switch (/DEC)
• External latch (/EXT 1 to 3)
• Forward run prohibited (P-OT), reverse run prohibited
(N-OT)
• Forward external torque limit (/P-CL), reverse external torque limit (/N-CL)
• DB answer (/DBANS)
Signal allocations can be performed, and positive and negative logic can be changed.
I/O
Signals
Communications
Function
LED Display
Sequence
Output
Fixed Output Servo alarm (ALM) output
Number of
Channels
3 ch
Output
Signals which can be allocated
Interface
Functions
• Positioning completion (/COIN)
• Speed coincidence detection (/V-CMP)
• Rotation detection (/TGON)
• Servo ready (/S-RDY)
• Torque limit detection (/CLT)
• Speed limit detection (/VLT)
• Brake (/BK)
• Warning (/WARN)
• Near (/NEAR)
Signal allocations can be performed, and positive and negative logic can be changed.
Digital operator (Model: JUSP-OP05A-1-E), personal computer (can be connected with SigmaWin+)
RS422A
Communications
(CN3)
USB
Communications
(CN7)
1:N
Communications
Axis
Address
Setting
Interface
Communications
Standard
N = Up to 15 stations possible at RS422A
Set by parameter
Personal computer (can be connected with SigmaWin+)
Complies with standard USB1.1. (12 Mbps)
MECHATROLINKII
Communications Setting Switches
Panel display (seven-segment), CHARGE, POWER, and COM indicators, one 7-segment LED
Rotary Switch
(S2)
Position: 16 positions (Refer to 4.1.1
)
DIP Switch (S3) Number of pins: Four pins (Refer to 4.1.1
)
Analog Monitor (CN5)
Dynamic Brake (DB)
*3
Regenerative Processing
Overtravel Prevention (OT)
Number of points: 2
Output voltage: ± 10VDC (linearity effective range ± 8 V)
Resolution: 16 bits
Accuracy: ± 20 mV (Typ)
Max. output current:
Settling time (
± 10 mA
± 1%): 1.2 ms (Typ)
Included
An external dynamic brake unit is required.
*4
Included
An external regenerative resistor unit is required.
*5
Dynamic brake stop, deceleration to a stop, or free run to a stop at P-OT or
N-OT
1.4 Ratings and Specifications
Protective Function
Utility Function
Safety Function
Input
Output
Standards
*6
(Application pending)
(cont’d)
Overcurrent, overvoltage, insufficient voltage, overload, regeneration error, and so on.
Gain adjustment, alarm history, JOG operation, origin search, and so on.
/HWBB1, /HWBB2: Baseblock signal for power module
EDM1: Monitoring status of internal safety circuit (fixed output)
EN 954 Category 3, IEC 61508 SIL2
Optional Module Fully-closed module, safety module
∗1.
Speed regulation by load regulation is defined as follows:
Speed regulation =
No-load motor speed Total load motor speed
Rated motor speed
∗2.
Refer to 4.2.10 Velocity Control (VEL CTRL: 3CH) of Σ
(No.: SIEP S800000 54) for details on the soft start function.
×
100%
Rotation
-V Series User’s Manual MECHATROLINK-II Commands
∗3.
Set Pn001 to n.
2 if you do not use the dynamic brake.
∗4.
Refer to 3.9 Selecting and Connecting a Dynamic Brake Unit for details on dynamic brake units.
∗5.
Refer to 3.8 Selecting and Connecting a Regenerative Resistor Unit for details on regenerative resistor unit.
∗6.
Implement risk assessment and confirm that the safety requirements of the machine have been met.
1.4.3
MECHATROLINK-
II
Function Specifications
The following table shows the specifications of MECHATROLINK-II.
MECHATROLINKII
Communication
Function
Control Method
Specifications
Communication Protocol
MECHATROLINK-II
Station Address
41H to 5FH (Max. number of stations: 30)
Can be selected by the combination of the rotary switch (S2) and the DIP switch (S3).
Baud Rate
10 Mbps, 4 Mbps
Can be selected by the DIP switch (S3).
Transmission Cycle 250 μ s, 0.5 ms to 4.0 ms (Multiples of 0.5 ms)
Number of Transmission Bytes
17 bytes per station or 32 bytes per station
Can be selected by the DIP switch (S3).
Position, speed, or torque control with MECHATROLINK-
II communication
Reference Method
Reference Input
MECHATROLINK-I , MECHATROLINK-II commands
(sequence, motion, data setting/reference, monitoring, or adjustment)
1
1-9
1-10
1 Outline
1.5.1 Three-phase 200 V
1.5
SERVOPACK and Converter Internal Block Diagrams
1.5.1
Three-phase 200 V
L1
Main circuit power supply
L2
L3
SPD
Fan 1 Fan 2
24 V 24 V
㧗
㧙
CHARGE
B1
Regenerative resistor unit
B2
P
+ -
P
㧗
㧙
Fan
1
Fan
2
Fan 3
(for 55-kW models only)
Fan
4
P24 V P24 V P24 V P24 V
CHARGE
M-II
DV
DU
Dynamic brake unit
DW
CN115
Servomotor
U
V
M
W
- 1
- 2
Voltage sensor
Temperature sensor
N N
Temperature sensor
Voltage sensor
Current sensor
Voltage sensor
MC drive
Voltage sensor gate drive
Gate drive
ENC
Varistor
L1C
Control power supply
L2C
㧗
㧙
Control power supply
+24 V
24C
CN103
+24 V
24C
CN104
+15 V
+24 V 2
+5 V
CN901
Converter I/O
SERVOPACK control power supply
CN901
Panel display
CN103
CN104
P24 V
0 V
24 V
㧗
㧙
15 V
㧗
㧙
Control power supply
+5 V
+24 V 6
ASIC
(PWM control, etc.)
CN2
CN5
Analog voltage converter
CN1
Analog monitor output
Encoder pulse output
CPU
(Position and speed calculation, etc.)
I/O I/O signals
CN6A CN6B CN21 CN22 CN31
CN3
Digital operator
PC
CN7 CN8
Safety function signals
1.5 SERVOPACK and Converter Internal Block Diagrams
1.5.2
Three-phase 400 V
L1
Main circuit power supply
L2
L3
- 1
- 2
Control power supply
( The 24-VDC power supply is not included.
)
+24 V
0 V
SPD
Fan
24 V
CHARGE
B1
Regenerative resistor unit
B2 + -
Fan
1
Fan
2
Fan 3
(for 55-kW models only)
Fan
4
P
P
P24 V P24 V P24 V P24 V
CHARGE
M-II
DV
DU
Dynamic brake unit
DW
CN115
Servomotor
U
V
M
W
Voltage sensor
MC drive
Voltage sensor
Temperature sensor
Voltage sensor gate drive
N N
Temperature sensor
Voltage sensor
Current sensor
Gate drive
ENC
Control power supply
CN103
+24 V
24C
CN901
Converter I/O
+24 V
24C
CN104
+15 V
+24 V×2
+5 V
SERVOPACK control power supply
CN901
Panel display
CN6A CN6B CN21 CN22
CN103
CN104
P24 V
0 V
24 V
Control power supply
±15 V
+5 V
+24 V×6
CN31
CN2
ASIC
(PWM control, etc.)
CN5
Analog voltage converter
CN1
Analog monitor output
Encoder pulse output
CPU
(Position and speed calculation, etc.)
CN3
Digital operator
I/O
CN7
PC
CN8
Safety function signals
I/O signals
1
1-11
1-12
1 Outline
1.6
Examples of Servo System Configurations
A system configuration for a three-phase main circuit power supply voltage of 400 VAC is shown in the following figure.
M-II
Power supply
Three-phase, 400 VAC
R S T
Molded-case circuit breaker
(MCCB)
Protects the power supply line by shutting the circuit OFF when overcurrent is detected.
Noise filter
Used to eliminate external noise from the power line.
Magnetic contactor
Turns the servo
ON and OFF.
Install a surge absorber.
100/200 VAC
Converter SERVOPACK
Connection cable for digital operator
Connection cable for personal computer
Digital operator
Personal computer
I/O signal cable
Connect to the
MECHATROLINK-
II
Host controller
DC power supply
(24 V) *1
Brake power supply *2
Used for a servomotor with a 90 V brake.
Magnetic contactor
Turns the brake power supply ON and OFF.
Install a surge absorber.
*3
*3
DB24
DU DV DW
DBON
Battery case
(when an absolute
encoder is used.)
Encoder cable
When not using the safety function, use the SERVOPACK with the safety function jumper connector inserted.
When using the safety function, insert a connection cable specifically for the safety function.
Safety function devices
Thermostat cable
Dynamic brake unit *5
Regenerative resistor *4
Molded-case circuit breaker
(MCCB)
Protects the motor fan by shutting the circuit OFF when overcurrent is detected.
Motor main circuit cable
Motor fan cable
SGMVV Servomotor
∗1.
Use a 24-VDC power supply with double insulation or reinforced insulation (The power supply is not included).
∗2.
The DC power supply for the 24-VDC brake is not included.
• For 200-V input voltage: LPSE-2H01-E
• For 100-V input voltage: LPDE-1H01-E
Use one of the following power supplies for 90-VDC brake. For details, contact your Yaskawa representative or the sales department. For details, refer to Large-Capacity Σ -V series Catalog (Manual no.: KAEP S800000 86).
∗3.
For details on grounding, refer to 3.10 Noise Control and Measures for Harmonic Suppression .
∗4.
Before connecting an external regenerative resistor unit, refer to 3.8 Selecting and Connecting a Regenerative Resistor Unit .
∗5.
For details on the dynamic brake unit, refer to 3.9 Selecting and Connecting a Dynamic Brake Unit .
1.7 SERVOPACK Model Designation
1.7
SERVOPACK Model Designation
This section shows SERVOPACK model designation .
SGDV –
1st + 2nd +
3rd digits
4th digit
5th + 6th
digits
7th digit
750 J 01 A
8th + 9th +
10th digits
000
11th + 12th
digits
00
13th digit
0
Series
SGDV Σ -V Series
7th digit: Design
Revision Order
Rotation
1st + 2nd + 3rd digits: Current
Voltage Code
Max. Allowable
Motor Capacity
(kW)
121 22
200 V 161 30
201 37
400 V
750 30
101 37
131 55
4th digit: Main Circuit
Power Supply
Voltage
Code Voltage
H
J
DC power input from separate
200-VAC converter
DC power input from separate
400-VAC converter
13th digit: Parameter Specification
Code Specification
0 Standard
11th + 12th digits: Software
Specification
Code Specification
00 Standard
5th + 6th digits: Interface Specifications
Code
01
11
21
Interface
Analog voltage and pulse train reference, rotational servomotor
MECHATROLINK-II communications reference, rotational servomotor
MECHATROLINK-III communications reference, rotational servomotor (under development)
E1 Command option for rotational servomotor
8th + 9th + 10th digits: Hardware Specifications
Code Specifications
000 Base-mounted (standard)
001 Duct-ventilated
002 Varnished
003 Duct-ventilated and Varnished
Note: When digits 8 to 13 are all zeros (0) in the model designation, the zeros are not shown.
1
1-13
1-14
1 Outline
1.8
Converter Model Designation
This section shows converter model designation .
SGDV –
1st + 2nd +
3rd digits
4th + 5th +
6th digits
7th digit
COA 3ZD A
Series
SGDV Σ -V Series
7th digit: Design
Revision Order
8th + 9th + 10th + 11th +
12th + 13th digits
000000
1st + 2nd + 3rd digits: Product group
Code Specifications
COA
Resistive regenerative converter
4th + 5th + 6th digits: Power Supply Capacity and Voltage Specifications
Code
Power Supply
Capacity
Voltage
2BA 22 kW
200 V
3GA 37 kW
3ZD 30 kW
5ED 55 kW
400 V
8th + 9th + 10th + 11th + 12th +13th digits:
Hardware Specifications
Code Specifications
000000 Base-mounted (standard)
001000 Dust-ventilated
002000 Varnished
003000 Dust-ventilated and Varnished
Note: When digits 8 to 13 are all zeros (0) in the model designation, the zeros are not shown.
1.9 Combinations of Servomotors, SERVOPACKs, and Converters
1.9
Combinations of Servomotors, SERVOPACKs, and
Converters
The following table lists the combinations of servomotors, SERVOPACKs, and converters.
Main Circuit Power
Supply Voltage
Three-phase
200 VAC
Three-phase
400 VAC
Servomotor
Motor speed Model: SGMVV-
1500 min
800 min
1500 min
800 min
-1
-1
-1
-1
2BA B
3ZA B
3GA B
2BA D
3ZA D
3GA D
2BD B
3ZD B
3GD B
4ED B
5ED B
2BD D
3ZD D
3GD D
4ED D
Capacity
30 kW
37 kW
45 kW
55 kW
22 kW
30 kW
37 kW
45 kW
22 kW
30 kW
37 kW
22 kW
30 kW
37 kW
22 kW
SERVOPACK
Model: SGDV-
121H
161H
201H
121H
161H
201H
750J
101J
131J
750J
101J
131J
Converter
Model: SGDV-
COA
2BAA
3GAA
2BAA
3GAA
3ZDA
5EDA
3ZDA
5EDA
1
1-15
1-16
1 Outline
1.10
Inspection and Maintenance
This section describes the inspection and maintenance of SERVOPACKs and converters.
(1) SERVOPACK or Converter Inspection
For inspection and maintenance of a SERVOPACK or converter, follow the inspection procedures in the following table at least once every year. Other routine inspections are not required.
Exterior
Item
Loose Screws
Frequency
At least once a year
Procedure
Check for dust, dirt, and oil on the surfaces.
Check for loose terminal block and connector screws.
Comments
Clean with compressed air.
Tighten any loose screws.
(2) Parts Replacement Schedule for a SERVOPACK or Converter
The following electric or electronic parts are subject to mechanical wear or deterioration over time. To avoid failure, replace these parts at the frequency indicated.
Refer to the standard replacement period in the following table and contact your Yaskawa representative.
After an examination of the part in question, we will determine whether the parts should be replaced or not.
The parameters of any SERVOPACKs overhauled by Yaskawa are reset to the factory settings before shipping. Be sure to confirm that the parameters are properly set before starting operation.
Part
Cooling Fan
Smoothing Capacitor
Other Aluminum Electrolytic
Capacitor
Relays
Fuses
Standard Replacement
Period
4 to 5 years
7 to 8 years
5 years
–
10 years
Operating Conditions
• Surrounding Air Temperature: Annual average of
30 ° C
• Load Factor: 80% max.
• Operation Rate: 20 hours/day max.
2
Panel Display and Operation of
Digital Operator
2.1 Panel Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.1 Status Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.2 Alarm and Warning Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.3 Hard Wire Base Block Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.4 Overtravel Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.2 Operation of Digital Operator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.3 Utility Functions (Fn ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
2.4 Parameters (Pn ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2.4.1 Parameter Classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2.4.2 Notation for Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2.4.3 Setting Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
2.5 Monitor Displays (Un ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
2
2-1
2-2
2 Panel Display and Operation of Digital Operator
2.1.1 Status Display
2.1
Panel Display
The servo drive status can be checked on the panel display of the SERVOPACK.
Also, if an alarm or warning occurs, its alarm or warning number is displayed.
2.1.1
Status Display
The display shows the following status.
Display Meaning
Rotation Detection (/TGON)
Lights if motor speed exceeds the value set in Pn502. (Factory setting: 20 min
-1
)
Baseblock
Lights for baseblock (Servomotor power OFF).
Reference Input
Lights when a reference is being input.
CONNECT
Lights during connection.
2.1.2
Alarm and Warning Display
If an alarm or warning occurs, the display will change in the following order.
Example: Alarm A.E60
Status
Display
Unlit Unlit Unlit Unlit Unlit MECHA
2.1.3
Hard Wire Base Block Display
If a hard wire base block (HWBB) occurs, the display will change in the following order.
Status
Display
Unlit Unlit Unlit Unlit
MECHA
2.1.4
Overtravel Display
If overtravelling occurs, the display will change in the following order.
1 Overtravel at forward rotation (P-OT)
Current status
2 Overtravel at reverse rotation (N-OT)
Current status
3 Overtravel at forward/reverse rotation
Current status
MECHA
2.2 Operation of Digital Operator
2.2
Operation of Digital Operator
Operation examples of utility functions (Fn ), parameters (Pn when using a digital operator are described in this chapter.
) and monitor displays (Un )
Operations can be also performed with SigmaWin+.
For more information on the usage of the digital operator, refer to
Digital Operator (No.: SIEP S800000 55).
Σ -V Series USER’S MANUAL Operation of
2
2-3
2-4
2 Panel Display and Operation of Digital Operator
2.3
Utility Functions (Fn )
The utility functions are related to the setup and adjustment of the SERVOPACK.
The digital operator shows numbers beginning with Fn.
The following table outlines the procedures necessary for an origin search (Fn003).
Step
1
Display after Operation
B B − F U N C T I O N −
F n 0 0 2 : J O G
F n 0 0 3 : Z − S e a r c h
F n 0 0 4 : P r o g r a m J O G
F n 0 0 5 : P r m I n i t
Keys Operation
Press the ity function.
Key to view the main menu for the util-
Use the or select Fn003.
Key to move through the list and
2
B B − Z − S e a r c h −
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 3 = 0 0 0 0 0 0 0 0 7 7 4
U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0
Press the Key. The display changes to the Fn003 execution display.
3
4
5
R U N − Z − S e a r c h −
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 3 = 0 0 0 0 0 0 0 0 7 7 4
U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0
R U N − C o m p l e t e −
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 3 = 0 0 0 0 0 0 0 0 0 0 0
U n 0 0 D = 0 0 0 0 0 0 0 1 D 5 8
B B
−
Z
−
S e a r c h
−
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 3 = 0 0 0 0 0 0 0 0 0 0 0
U n 0 0 D = 0 0 0 0 0 0 0 1 D 5 8
Press the Key.
The status display changes from "BB" to "RUN", and the servomotor power turns ON.
Note: If the servomotor is already at the zero position,
"-Complete-" is displayed.
Pressing the Key will rotate the servomotor in the forward direction. Pressing the Key will rotate the servomotor in the reverse direction. The rotation direction of the servomotor changes according to the setting of Pn000.0 as shown in the following table.
Parameter key key
Pn000 n.
n.
0
1
CCW
CW
CW
CCW
Note: Direction when viewed from the load of the servomotor.
Press the or Key until the servomotor stops.
If the origin search completed normally, "-Complete-" is displayed on the right top on the screen.
When the origin search is completed, press the
Key.
The status display changes from "RUN" to "BB", and the servomotor turns OFF. The display "-Complete-" changes to "-Z-Search-."
6
B B − F U N C T I O N −
F n 0 0 2 : J O G
F n 0 0 3 : Z − S e a r c h
F n 0 0 4 : P r o g r a m J O G
F n 0 0 5 : P r m I n i t
Press the Key.
The display returns to the main menu of the utility function.
7 To enable the change in the setting, turn the power to the SERVOPACK and converter OFF and ON again.
2.4 Parameters (Pn )
2.4
Parameters (Pn )
This section describes the classifications, methods of notation, and settings for parameters given in this manual.
2.4.1
Parameter Classification
Two types of parameters are used in Σ -V large-capacity SERVOPACKs. One type of parameters is required for setting up the basic conditions for operation and the other type is required for tuning parameters that are required to adjust servomotor characteristics.
Classification
Setup Parameters
Tuning Parameters
Meaning
Parameters required for setup.
Parameters for tuning control gain and other parameters.
Display Method
Always displayed (Factory setting: Pn00B.0 = 0)
Set Pn00B.0 to 1.
Setting Method
Set each parameter individually.
There is no need to set each parameter individually.
There are two types of notation used for parameters, one for parameter that requires a value setting (parameter for numeric settings) and one for parameter that requires the selection of a function (parameter for selecting functions).
The notation and settings for both types of parameters are described next.
2.4.2
Notation for Parameters
(1) Parameters for Numeric Settings
The control methods for which the parameters applies.
Speed : Speed control Position : Position control Torque : Torque control
Pn406
Emergency Stop Torque
Setting Range
0 to 800
Setting Unit
1%
Speed
Factory Setting
800
Position Torque
When Enabled
After change
Parameter number
Indicates the setting range for the parameter.
Indicates the minimum setting unit for the parameter.
Indicates the parameter setting before shipment.
Indicates when a change to the parameter will be effective.
Classification
Setup
Indicates the parameter classification.
(2) Parameters for Selecting Functions
Pn002
Parameter Meaning n.
0
[Factory setting]
Uses the absolute encoder as an absolute encoder. n.
1
Uses the absolute encoder as an incremental encoder.
Parameter number
When Enabled Classification
After restart Setup
The notation “n.
” indicates a parameter for selecting functions. Each corresponds to the setting value of that digit. The notation shown here means that the third digit is 1.
This section explains the selections for the function.
Rotation
2
2-5
2-6
2 Panel Display and Operation of Digital Operator
2.4.3 Setting Parameters
• Notation Example
MECHA
Digital Operator Display (Display Example for Pn002)
㨚㧜㧜㧜㧜
1st digit
2nd digit
Notation
Digit Notation
Meaning
Pn002.0
Pn002.1
Indicates the value for the
1st digit of parameter Pn002.
Indicates the value for the
2nd digit of parameter Pn002.
3rd digit
4th digit
Pn002.2
Pn002.3
Indicates the value for the
3rd digit of parameter Pn002.
Indicates the value for the
4th digit of parameter Pn002.
Notation
Setting Notation
Meaning
Pn002.0 = x or n.
x
Indicates that the value for the
1st digit of parameter Pn002 is x.
Pn002.1 = x or n.
x
Indicates that the value for the
2nd digit of parameter Pn002 is x.
Pn002.2 = x or n.
x
Indicates that the value for the
3rd digit of parameter Pn002 is x.
Pn002.3 = x or n.x
Indicates that the value for the
4th digit of parameter Pn002 is x.
2.4.3
Setting Parameters
(1) How to Make Numeric Settings Using Parameters
The following example shows how to change the setting of parameter Pn304 (JOG speed) to 1000 min -1 .
Keys Operation Step
1
Display after Operation
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㨁㨚㧜㧜㧜㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
2
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㨁㨚㧜㧜㧜㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
3
4
5
6
7
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧜㧜㧜㧩㨚㧜㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧜㧜㧜㧩㨚㧜㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜㨜㨡㨘㨟㨑
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧟㧜㧠㧩㧜㧜㧡㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧟㧜㧠㧩㧜㧜㧡㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧟㧜㧠㧩㧜㧜㧡㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
8
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧟㧜㧠㧩㧜㧝㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
Press the Key to select the main menu of parameters and monitor displays.
Press the or Key to move the cursor to "Un."
Press the or Key to change "Un" to "Pn."
Press the Key to move the cursor to the column on the right of "Pn."
Press the arrow keys to display "Pn304".
To move the cursor to different columns: ,
Key
To change the settings: , Key
Press the Key to move the cursor to the one’s place of Pn304.
Press the Key twice to move the cursor to the hundred’s place of Pn304.
Press the Key five times to change the setting to
"1000."
2.4 Parameters (Pn )
Step
9
Display after Operation
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧟㧜㧠㧩㧜㧝㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
Keys Operation
Press the Key to write the settings.
(cont’d)
(2) How to Select Functions Using Parameters
The following example shows how to set the function section for insufficient voltage of the application function select switch 8 (Pn008) to 1 "detects warning and limits torque by host controller."
Keys Operation Step
1
2
3
4
5
6
7
8
9
Display after Operation
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㨁㨚㧜㧜㧜㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㨁㨚㧜㧜㧜㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧜㧜㧜㧩㨚㧜㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧜㧜㧜㧩㨚㧜㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧜㧜㧤㧩㨚㧠㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧜㧜㧤㧩㨚㧠㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧜㧜㧤㧩㨚㧠㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㧼㨚㧜㧜㧤㧩㨚 㧠㧜㧝㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
Press the Key to select the main menu of parameters and monitor displays.
Press the or Key to move the cursor to
"Un."
Press the
Press the to "1."
or Key to change "Un" to "Pn."
Press the Key three times to move the cursor to the column on the right of "Pn."
Press the Key to display "Pn008."
Press the Key to move the cursor to "Pn008.0."
Press the Key once to move the cursor to
"Pn008.1."
Key to change the setting of "Pn008.1"
Press the Key to write the settings.
2
2-7
2-8
2 Panel Display and Operation of Digital Operator
2.5
Monitor Displays (Un )
The monitor displays can be used for monitoring the reference values, I/O signal status, and SERVOPACK internal status.
For details, refer to 7.2 Viewing Monitor Displays .
The digital operator shows numbers beginning with Un.
The following four settings are the factory settings.
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㨁㨚㧜㧜㧜㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
Shows the setting of Un000 (motor rotating speed) as 0 min
-1
.
MECHA
3
Wiring and Connection
3.1 Main Circuit Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
3.1.1 Main Circuit Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
3.1.2 Main Circuit Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
3.1.3 Typical Main Circuit Wiring Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14
3.1.4 General Precautions for Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18
3.1.5 Discharging Time of the Main Circuit’s Capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-20
3.2 Connecting the Converter to the SERVOPACK . . . . . . . . . . . . . . . . . . . 3-21
3.2.1 Connecting the Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-21
3.2.2 Interconnecting Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-21
3.3 I/O Signal Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23
3.3.1 I/O Signal (CN1) Names and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23
3.3.2 Safety Function Signal (CN8) Names and Functions . . . . . . . . . . . . . . . . . . . . . . . . 3-24
3.3.3 Example of I/O Signal Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-25
3.4 I/O Signal Allocations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-26
3.4.1 Input Signal Allocations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-26
3.4.2 Output Signal Allocations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-27
3.5 Examples of Connection to Host Controller . . . . . . . . . . . . . . . . . . . . . . 3-29
3.5.1 Sequence Input Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-29
3.5.2 Sequence Output Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-31
3.6 Wiring MECHATROLINKII Communications . . . . . . . . . . . . . . . . . . . . . 3-33
3.7 Encoder Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-34
3.7.1 Encoder Signal (CN2) Names and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-34
3.7.2 Encoder Connection Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-34
3.8 Selecting and Connecting a Regenerative Resistor Unit . . . . . . . . . . . . 3-36
3.8.1 Selecting a Regenerative Resistor Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-36
3.8.2 Connecting a Regenerative Resistor Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-37
3.8.3 Setting Regenerative Resistor Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-38
3.8.4 Installation Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-39
3.9 Selecting and Connecting a Dynamic Brake Unit . . . . . . . . . . . . . . . . . . 3-40
3.9.1 Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-40
3.9.2 Selecting the Cable for the Dynamic Brake Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-40
3.9.3 Setting the Dynamic Brake Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-41
3.9.4 Setting the Dynamic Brake Answer Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-42
3.9.5 Installation Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-43
3.9.6 Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-43
3
3-1
3-2
3 Wiring and Connection
3.10 Noise Control and Measures for Harmonic Suppression . . . . . . . . . . 3-46
3.10.1 Wiring for Noise Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-46
3.10.2 Precautions on Connecting Noise Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-48
3.10.3 Connecting a Reactor for Harmonic Suppression . . . . . . . . . . . . . . . . . . . . . . . . . . 3-50
3.1 Main Circuit Wiring
3.1
Main Circuit Wiring
The names and specifications of the main circuit terminals are given below.
Also this section describes the general precautions for wiring and precautions under special environments.
3.1.1
Main Circuit Terminals
The names and specifications of the main circuit terminals are given below.
Note: For the purpose of this description, the SERVOPACK is shown with the front cover removed. Always keep the front cover attached when using the SERVOPACK.
SERVOPACK
M-II
CN115
CN103, CN104
P, N
DU, DV, DW
U, V, W
Terminals
P, N
U, V, W
CN103,
CN104
DU, DV,
DW
Name
Main circuit DC voltage input terminals
Servomotor terminals
Specifications
Connect these terminals to the P and N terminals on the converter.
Control power input connectors
Connect these terminals to the Servomotor terminals.
CN103 is the 24 VDC ( ± 15%) input. CN104 takes the same input, but it is normally not necessary to connect it.
Dynamic brake unit terminals Connect these terminals to the dynamic brake unit.
CN115
+, -
Dynamic brake unit connector
NC
Ground terminal
Connect this connector to the DBON and DB24 terminals on the dynamic brake unit.
Do not connect these terminals.
Connect this terminal to the power supply ground terminal and the
Servomotor ground terminal, and then ground it.
3
3-3
3-4
3 Wiring and Connection
3.1.1 Main Circuit Terminals
Converter
Converter
SGDV-COA2BAA
SGDV-COA3ZDA
CN101
CN103,
CN104
CN101
CN103,
CN104
Converter
SGDV-COA3GAA
SGDV-COA5EDA
1, ޓ 2
L1, L2, L3
1, ޓ 2
P, N
B1, B2
B1, B2
L1, L2, L3
P, N
Terminals
L1, L2, L3 Main circuit power input terminals
CN101
Name
Control power input connector
Specifications
SGDV-COA AA: Three-phase, 200 to 230 VAC, +10% to -
15%, 50/60 Hz
SGDV-COA DA: Three-phase, 380 to 480 VAC, +10% to -
15%, 50/60 Hz
SGDV-COA AA: Single-phase, 200 to 230 VAC, +10% to -
15%, 50/60 Hz
SGDV-COA DA: 24 VDC, ± 15%
Mating connector model: 231-202/026-000 (Manufactured by
Wago Company of Japan, Ltd)
Pin 2: 24 V
Pin 1: 0 V
P, N
B1, B2
1, 2
CN103,
CN104
Main circuit DC voltage output terminals
Ground terminal
Connect these terminals to the P and N terminals on the SERVO-
PACK.
Connect this terminal to the power supply ground terminal and then ground it.
Regenerative resistor connection terminals
DC reactor connection terminals
Connect these terminals to the regenerative resistor unit.
Control power output connectors
Remove the short bar before you connect a DC reactor.
CN103 and CN104 output 24 VDC to the SERVOPACK.
For a 400-V system, the 24-VDC ( ± 15%) input is output unaltered from CN103. CN104 provides the same output, but it is normally not necessary to connect it.
3.1 Main Circuit Wiring
3.1.2
Main Circuit Wire
This section describes the main circuit wires for SERVOPACKs and converters.
• The specified wire sizes are for use when the three lead cables are bundled and when the rated electric current is applied with a surrounding air temperature of 40 ° C.
• Use a wire with a minimum withstand voltage of 600 V for the main circuit.
• If cables are bundled in PVC or metal ducts, take into account the reduction of the allowable current.
• Use a heat-resistant wire under high surrounding air or panel temperatures, where polyvinyl chloride insulated wires will rapidly deteriorate.
(1) Wire Types
Use the following type of wire for main circuit.
IV
Symbol
HIV
Cable Type
Name
600 V polyvinyl chloride insulated wire
600 V grade heat-resistant polyvinyl chloride insulated wire
Allowable Conductor Temperature
( ° C)
60
75
The following table shows the wire sizes and allowable currents for three wires.
Use wires with specifications equal to or less than those shown in the table.
Nominal Cross
Section Diameter
(mm
2
)
8
14
22
38
60
100
0.5
0.75
0.9
1.25
2
3.5
5.5
AWG Size
Configuration
(Number of Wires/ mm)
(20)
(19)
(18)
(16)
(14)
(12)
(10)
(8)
(6)
(4)
(1)
(2/0)
(4/0)
7/1.2
7/1.6
7/2.0
7/2.6
19/2.0
19/2.6
19/0.18
30/0.18
37/0.18
50/0.18
7/0.6
7/0.8
7/1.0
Conductive
Resistance ( Ω / km)
2.41
1.35
0.85
0.49
0.30
0.18
39.5
26
24.4
15.6
9.53
5.41
3.47
91
124
170
240
33
43
55
79
Allowable Current at Surrounding Air
Temperature (A)
30 ° C
6.6
40 °
5.6
C 50 °
4.5
C
8.8
9
12
23
7
7.7
11
20
5.5
6
8.5
16
29
38
49
70
81
110
150
212
66
93
127
179
24
31
40
57
Note: These are reference values for 600-V-grade, heat-resistant, PVC-insulated wire.
3
3-5
3-6
3 Wiring and Connection
3.1.2 Main Circuit Wire
(2) Wire Sizes
The following table shows the symbols for the power input terminals, screw sizes for terminals, tightening torque, wire sizes, and crimp terminals used for the SERVOPACKs and converters.
For Three-phase, 200V
Combination of SERVO-
PACK and Converter
*1
Terminal
Symbols
Screw Size for Terminals
Tightening
Torque
(N m)
HIV Wire Size in mm
2
(AWG)
SGDV-121H
SERVO-
PACK
P, N
U, V, W
DU, DV, DW
P, N
M8
M8
M6
M8
M8
15.0
3.0
3.0
9.0 to 1.0
3.0
Bus bar attached to the converter
60 (2/0)
5.5 (10)
60 (2/0)
Bus bar attached to the converter
38 (1)
SGDV-
COA2BAA
SGDV-161H
Converter
SERVO-
PACK
L1, L2, L3
1, 2
CN101
(L1C, L2C)
B1, B2
P, N
U, V, W
DU, DV, DW
M8
M8
–
(Connector)
M8
M8
M8
M8
M6
M8
3.0
–
3.0
9.0 to 11.0
15.0
3.0
3.0
9.0 to 11.0
1.25 (16)
8 (8)
38 (1)
Bus bar attached to the converter
100 (4/0)
5.5 (10)
100 (4/0)
Bus bar attached to the converter
60 (2/0)
60 (2/0)
SGDV-
COA3GAA
SGDV-201H
Converter
SERVO-
PACK
P, N
L1, L2, L3
1, 2
CN101
(L1C, L2C)
B1, B2
P, N
U, V, W
DU, DV, DW
P, N
M10
M10
M10
–
(Connector)
M10
M8
M10
M10
M6
M8
M10
12 to 20
12 to 20
12 to 20
–
12 to 20
9.0 to 11.0
12 to 20
30.0
3.0
9.0 to 11.0
12 to 20
SGDV-
COA3GAA
Converter
L1, L2, L3
1, 2
CN101
(L1C, L2C)
B1, B2
M10
M10
–
(Connector)
M10
M8
12 to 20
12 to 20
–
12 to 20
9.0 to 11.0
∗1.
Use SERVOPACKs and converters in the specified combinations.
∗2.
Use the crimp terminals that are recommended by Yaskawa or an equivalent.
1.25 (16)
14 (6)
60 (2/0)
Bus bar attached to the converter
100 (4/0)
5.5 (10)
100 (4/0)
Bus bar attached to the converter
100 (4/0)
100 (4/0)
1.25 (16)
14 (6)
100 (4/0)
Crimp Terminal
Model
(Made by J.S.T.
Mfg Co., Ltd.)
*2
–
R60-8
R5.5-6
R60-8
–
R100-10
R100-10
–
R14-10
100-8
–
R60-10
R60-10
–
R14-10
R60-8
–
R38-8
R38-8
–
R8-8
R38-8
–
CB100-S8
R5.5-6
100-8
–
R100-10
R5.5-6
100-8
3.1 Main Circuit Wiring
For Three-phase, 400V
Combination of SERVO-
PACK and Converter
*1
Terminal
Symbols
Screw Size for Terminals
Tightening
Torque
(N m)
HIV Wire Size in mm
2
(AWG)
SGDV-750J
SGDV-
COA3ZDA
SERVO-
PACK
P, N
U, V, W
DU, DV, DW
M8
M8
M6
M8
15.0
3.0
3.0
9.0 to 11.0
3.0
3.0
Bus bar attached to the converter
22 (4)
3.5 (12)
22 (4)
Bus bar attached to the converter
22 (4)
Converter
P, N
L1, L2, L3
1, 2
CN101
(24 V, 0 V)
B1, B2
P, N
U, V, W
DU, DV, DW
M8
M8
M8
–
(Connector)
M8
M8
– 1.25 (16)
SGDV-101J
SGDV-
COA5EDA
SERVO-
PACK
P, N
P, N
U, V, W
DU, DV, DW
M8
M8
M6
M8
M10
3.0
9.0 to 11.0
15.0
3.0
3.0
9.0 to 11.0
12 to 20
12 to 20
12 to 20
12 to 20
12 to 20
12 to 20
8 (8)
22 (4)
Bus bar attached to the converter
38 (1)
3.5 (12)
38 (1)
Bus bar attached to the converter
38 (1)
38 (1)
SGDV-131J
SGDV-
COA5EDA
Converter
SERVO-
PACK
Converter
L1, L2, L3
1, 2
CN101
(24 V, 0 V)
B1, B2
P, CN
L1, L2, L3
1, 2
CN101
(24 V, 0 V)
B1, B2
M10
M10
–
(Connector)
M10
M8
M10
M10
M6
M8
M10
M10
M10
–
(Connector)
M10
M8
–
12 to 20
9.0 to 11.0
12 to 20
30.0
3.0
9.0 to 11.0
–
12 to 20
9.0 to 11.0
∗1.
Use SERVOPACKs and converters in the specified combinations.
∗2.
Use the crimp terminals that are recommended by Yaskawa or an equivalent.
1.25 (16)
8 (8)
38 (1)
Bus bar attached to the converter
60 (2/0)
3.5 (12)
60 (2/0)
Bus bar attached to the converter
60 (2/0)
60 (2/0)
1.25 (16)
14 (6)
60 (2/0)
Crimp Terminal
Model
(Made by J.S.T.
Mfg Co., Ltd.)
*2
–
R22-8
3.5-6
R22-8
–
R38-10
R38-10
–
R8-10
R38-8
–
R60-10
3.5-6
R60-8
–
R60-10
R60-10
–
R14-10
R60-8
–
R22-8
R22-8
–
R8-8
R22-8
–
R38-8
3.5-6
R38-8
3
3-7
3-8
3 Wiring and Connection
3.1.2 Main Circuit Wire
Tools for Crimp Terminals
Model
3.5-6
R5.5-6
R8-8
R8-10
R14-10
R22-8
R38-8
R38-10
R60-8
R60-10
100-8
R100-10
CB100-S8
Body
YHT-2210
YHT-8S
YPT-150-1
Tools (by J.S.T. Mfg Co., Ltd.)
Head
–
–
–
Body only: YPT-150-1 or
Body: YF-1; Head: YET-150-1
Dies
–
–
TD-221, TD-211
TD-222, TD-211
TD-223, TD-212
TD-224, TD-212
TD-225, TD-213
TD-228, TD-214
3.1 Main Circuit Wiring
(3) Wire Size (UL Standard)
To comply with the UL standard, use the recommended wires.
The following table shows the wire sizes (AWG) at a rating of 75 ° C.
For Three-phase, 200V
Combination of SERVOPACK and
Converter
*
Terminal Symbols
Screw Size for
Terminals
SGDV-121H
SGDV-
COA2BAA
SGDV-161H
SGDV-
COA3GAA
SERVOPACK
Converter
SERVOPACK
Converter
P, N
U, V, W
DU, DV, DW
P, N
L1, L2, L3
1, 2
CN101
(L1C, L2C)
B1, B2
P, N
U, V, W
DU, DV, DW
P, N
L1, L2, L3
1, 2
CN101
(L1C, L2C)
B1, B2
SERVOPACK
P, N
U, V, W
DU, DV, DW
M10
M10
M6
M8
SGDV-201H
SGDV-
COA3GAA
Converter
P, N
L1, L2, L3
1, 2
CN101
(L1C, L2C)
B1, B2
∗ Use SERVOPACKs and converters in the specified combinations.
M10
M10
M10
–
(Connector)
M10
M8
M8
M8
M6
M8
M8
M8
M8
–
(Connector)
M8
M8
M8
M8
M6
M8
M10
M10
M10
–
(Connector)
M10
M8
Tightening
Torque
(N m)
Wire Size AWG
15.0
3.0
3.0
9.0 to 11.0
Bus bar attached to the converter
1/0
10
1/0
3.0
3.0
Bus bar attached to the converter
1/0
3.0 1/0
–
3.0
9.0 to 11.0
15.0
3.0
3.0
9.0 to 11.0
12 to 20
12 to 20
12 to 20
–
12 to 20
9.0 to 11.0
14
6
1/0
Bus bar attached to the converter
3/0
10
3/0
Bus bar attached to the converter
3/0
3/0
12 to 20
30.0
3.0
9.0 to 11.0
12 to 20
12 to 20
12 to 20
–
12 to 20
9.0 to 11.0
14
4
3/0
Bus bar attached to the converter
250
10
250
Bus bar attached to the converter
4/0
4/0
14
4
4/0
3
3-9
3-10
3 Wiring and Connection
3.1.2 Main Circuit Wire
For Three-phase, 400V
Combination of SERVOPACK and
Converter
*
Terminal Symbols
SGDV-750J
SGDV-
COA3ZDA
SGDV-101J
SGDV-
COA5EDA
SERVOPACK
Converter
SERVOPACK
Converter
P, N
U, V, W
DU, DV, DW
P, N
L1, L2, L3
1, 2
CN101
(24 V, 0 V)
B1, B2
P, N
U, V, W
DU, DV, DW
P, N
L1, L2, L3
1, 2
CN101
(24 V, 0 V)
B1, B2
SERVOPACK
P, N
U, V, W
DU, DV, DW
M10
M10
M6
M8
SGDV-131J
SGDV-
COA5EDA
Converter
P, N
L1, L2, L3
1, 2
CN101
(24 V, 0 V)
B1, B2
∗ Use SERVOPACKs and converters in the specified combinations.
M10
M10
M10
–
(Connector)
M10
M8
M8
M8
M6
M8
M10
M10
M10
–
(Connector)
M10
M8
M8
M8
M6
M8
M8
M8
M8
–
(Connector)
M8
M8
Screw Size for
Terminals
Tightening
Torque
(N m)
Wire Size AWG
15.0
3.0
3.0
9.0 to 11.0
Bus bar attached to the converter
3
10
3
3.0
3.0
Bus bar attached to the converter
3
3.0 3
–
3.0
9.0 to 11.0
15.0
3.0
3.0
9.0 to 11.0
12 to 20
12 to 20
12 to 20
14
8
3
Bus bar attached to the converter
1
10
1
Bus bar attached to the converter
2
2
–
12 to 20
9.0 to 11.0
12 to 20
30.0
3.0
9.0 to 11.0
12 to 20
12 to 20
12 to 20
–
12 to 20
9.0 to 11.0
14
8
2
Bus bar attached to the converter
2/0
10
2/0
Bus bar attached to the converter
2/0
2/0
14
4
2/0
3.1 Main Circuit Wiring
Crimp Terminal, Sleeve, Terminal Kit
• For Three-phase, 200V
Combination of
SERVOPACK and
Converter
SGDV-121H
SGDV-
COA2BAA
SGDV-161H
SGDV-
COA3GAA
SGDV-201H
SGDV-
COA3GAA
SERVOPACK
Converter
SERVOPACK
Converter
SERVOPACK
Converter
Terminal
Symbols
U, V, W
DU, DV, DW
L1, L2, L3
1, 2
B1, B2
U, V, W
DU, DV, DW
L1, L2, L3
1, 2
B1, B2
U, V, W
DU, DV, DW
L1, L2, L3
1, 2
B1, B2
Crimp Terminal
Model (Made by
J.S.T. Mfg Co.,
Ltd.)
*1
R60-8
R5.5-6
Sleeve Model
(Made by Tokyo
Dip Co., Ltd.)
*2
TP-060 (black)
TP-006 (black)
R60-8
R60-8
R60-8
R14-8
R60-8
CB80-S8
R5.5-6
80-8
–
TP-060 (black)
TP-060 (white)
TP-022 (white)
–
TP-100 (black)
TP-006 (black)
–
80-10
80-10
R22-10
80-8
CB150-S10
R5.5-6
150-8
R100-10
R100-10
R22-10
100-8
TP-100 (black)
TP-100 (white)
TP-038 (white)
–
TP-150 (black)
TP-006 (black)
–
TP-125 (black)
TP-125 (white)
TP-038 (white)
–
Terminal Kit Model
*3
JZSP-CVT9-121H-E
JZSP-CVT9-2BA-E
JZSP-CVT9-161H-E
JZSP-CVT9-3GA1-E
JZSP-CVT9-201H-E
JZSP-CVT9-3GA2-E
∗1.
Use SERVOPACKs and converters in the specified combinations.
∗2.
Use sleeves for the crimped section of the terminals.
∗3.
A terminal kit includes the crimp terminals and sleeves required for one SERVOPACK or converter.
3
3-11
3-12
3 Wiring and Connection
3.1.2 Main Circuit Wire
• For Three-phase, 400V
Combination of SERVO-
PACK and Converter
SGDV-750J
SGDV-
COA3ZDA
SGDV-101J
SGDV-
COA5EDA
SGDV-131J
SGDV-
COA5EDA
SERVOPACK
Converter
SERVOPACK
Converter
SERVOPACK
Converter
Terminal Symbols
U, V, W
DU, DV, DW
L1, L2, L3
1, 2
B1, B2
U, V, W
DU, DV, DW
L1, L2, L3
1, 2
B1, B2
U, V, W
DU, DV, DW
L1, L2, L3
1, 2
B1, B2
R38-10
R38-10
R8-10
R38-8
70-10
R5.5-6
70-8
70-10
70-10
R22-10
70-8
Crimp Terminal
Model (Made by
J.S.T. Mfg Co.,
Ltd.)
*1
R38-8
R5.5-6
Sleeve Model
(Made by Tokyo
Dip Co., Ltd.)
*2
TP-038 (black)
TP-006 (black)
R38-8
R38-8
R38-8
R8-8
R38-8
R60-8
R5.5-6
R60-8
–
TP-038 (black)
TP-038 (white)
TP-014 (white)
–
TP-060 (black)
TP-006 (black)
–
TP-038 (black)
TP-038 (white)
TP-014 (white)
–
TP-080 (black)
TP-006 (black)
–
TP-080 (black)
TP-080 (white)
TP-038 (white)
–
Terminal Kit Model
JZSP-CVT9-750J-E
JZSP-CVT9-3ZD-E
JZSP-CVT9-101J-E
*3
JZSP-CVT9-5ED1-E
JZSP-CVT9-131J-E
JZSP-CVT9-5ED2-E
∗1.
Use SERVOPACKs and converters in the specified combinations.
∗2.
Use sleeves for the crimped section of the terminals.
∗3.
A terminal kit includes the crimp terminals and sleeves required for one SERVOPACK or converter.
3.1 Main Circuit Wiring
Tools for Crimp Terminals
Model
R5.5-6
R8-8
R14-8
R22-10
R38-8
R38-10
R60-8
70-8
70-10
80-8
80-10
CB80-S8
100-8
R100-10
150-8
CB150-S10
Body
YHT-2210
YHT-8S
YPT-150-1
Tools by J.S.T. Mfg Co., Ltd.
Head
–
–
–
Body only: YPT-150-1 or
Body: YF-1; Head: YET-150-1
Dies
–
–
TD-221, TD-211
TD-222, TD-211
TD-223, TD-212
TD-224, TD-212
TD-225, TD-213
TD-226, TD-213
TD-227, TD-214
TD-228, TD-214
TD-229, TD-215
3
3-13
3-14
3 Wiring and Connection
3.1.3 Typical Main Circuit Wiring Examples
3.1.3
Typical Main Circuit Wiring Examples
Note the following points when designing the power ON sequence.
• Design the power ON sequence so that main power is turned OFF when a servo alarm signal (ALM) is output.
• The ALM signal is output for a maximum of five seconds when the control power is turned ON. Take this into consideration when designing the power ON sequence. Design the sequence so the ALM signal is activated and the alarm detection relay (1Ry) is turned OFF to stop the main circuit’s power supply to the SERVOPACK and converter.
Control power supply 5.0 s max.
ALM signal
• Select the power supply specifications for the parts in accordance with the input power supply.
• When turning ON the control power supply and the main circuit power supply, turn them ON at the same time or turn the main circuit power supply after the control power supply. When turning OFF the power supplies, first turn the power for the main circuit OFF and then turn OFF the control power supply.
The typical main circuit wiring examples are shown below.
WARNING
• Do not touch the power supply terminals after turning OFF the power. High voltage may still remain in the
SERVOPACK and the converter, resulting in electric shock. When the voltage is discharged, the charge indicator will turn OFF. Make sure the charge indicator is OFF before starting wiring or inspections.
3.1 Main Circuit Wiring
(1) Single-axis Application
Three-phase 200 V
3SA
Three-phase,
200 VAC
R S T
1QF
1FLT
1Ry
Regenerative resistor unit
2KM
1KM
Servo power supply ON
Servo power supply OFF 1KM
1
2
1KM
1KM 1Ry
1SA
2KM
2SA a b
1QF: Molded-case circuit breaker
2QF: Molded-case circuit breaker
1FIL: Noise filter
1KM: Magnetic contactor (for control power supply)
2KM: Magnetic contactor (for main power supply)
1Ry: Relay
B2
P
N
L1
L2
L3
CN103
CN101
L1C
L2C
CN901
B1
2QF
Converter
U
V
W
SERVOPACK
DU
DV
DW
P
N
CN115 DB24
DBON
U
V
W
Dynamic brake unit
CN103
CN2
C B A
Fan
Thermostat
1
M
1b
ENC
CN901
CN1
31 ALM+
1Ry
+24 V
32 ALM1D 0 V
1PL: Indicator lamp
1SA: Surge absorber
2SA: Surge absorber
3SA: Surge absorber
1D: Flywheel diode a b
3
3-15
3-16
3 Wiring and Connection
3.1.3 Typical Main Circuit Wiring Examples
Three-phase 400 V
3SA
100/200 VAC
Three-phase,
400 VAC
R S T
1QF
1FLT
Regenerative resistor unit
DC power supply
(24 V)
+
-
2KM
1KM
2QF
Converter
B1
B2
P
N
L1
L2
L3
CN103
CN101
24 V
0 V
CN901
SERVOPACK
Dynamic brake unit
DU
DV
DW
P
N
CN115 DB24
DBON
U
V
W
CN103
CN2
U
V
W
C B A
Fan
Thermostat
1
M
1b
ENC
1Ry
Servo power Servo power supply ON supply OFF
1KM
1
2
CN901
CN1
31 ALM+
1Ry
+24 V
32 ALM1D 0 V
1KM
1KM 1Ry
1SA
2KM
2SA a b
1QF: Molded-case circuit breaker
2QF: Molded-case circuit breaker
1FIL: Noise filter
1KM: Magnetic contactor (for control power supply)
2KM: Magnetic contactor (for main power supply)
1Ry: Relay
1PL: Indicator lamp
1SA: Surge absorber
2SA: Surge absorber
3SA: Surge absorber
1D: Flywheel diode a b
3.1 Main Circuit Wiring
(2) Multi-axis Application
Connect the alarm output (ALM) terminals for three SERVOPACKs in series to enable alarm detection relay
1RY to operate. When the alarm occurs, the ALM output signal transistor is turned OFF.
The following diagram shows a wiring example for three-phase, 400-VAC SERVOPACK with converter.
Three-phase,
400 VAC
R S T
1QF
3SA Relay terminal
2QF
1FLT
U
V
W
2KM
100/200 VAC
DC power supply (24 V)
+
-
1KM
(For servo alarm display)
1Ry
1PL
Servo power supply ON
Servo power supply OFF 1KM
1KM
1KM 1Ry
1SA
2KM a b
2SA
Relay terminal
Relay terminal
Relay terminal
Relay terminal
Converter
L1
L2
L3
CN901
CN101
24 V
0 V
P
N
CN103
SERVOPACK
P
N
U
V
W
CN103
CN1
31
CN901
ALM+
1Ry
32 ALM1D
+24 V
Fan
C B A
Thermostat
1 a
M
1b
3QF
Converter SERVOPACK
L1
L2
L3
P
N
CN103
Relay terminal
CN901
CN101
24 V
0 V
P
N
U
V
W
CN103
CN1
31 ALM+
CN901
32 ALM-
U
V
W
Fan
C B A
Thermostat
1
M
1b
L1
L2
L3
4QF
Converter SERVOPACK
P
N
P
N
U
V
W
U
V
W
Fan
C B A
Thermostat
1
M
1b b
1QF: Molded-case circuit breaker
2QF: Molded-case circuit breaker
3QF: Molded-case circuit breaker
4QF: Molded-case circuit breaker
1FIL: Noise filter
1KM: Magnetic contactor
(for control power supply)
2KM: Magnetic contactor
(for main power supply)
1Ry: Relay
1PL: Indicator lamp
1SA: Surge absorber
2SA: Surge absorber
3SA: Surge absorber
1D: Flywheel diode
CN103
CN901
CN101
24 V
0 V
CN103
CN1
31
CN901
ALM+
32 ALM-
0 V
Precautions
Multiple SERVOPACKs and converters can share a single molded-case circuit breaker (1QF) or noise filter.
Always select a molded-case circuit breaker or noise filter that has enough capacity for the total power supply capacity (load conditions) of the SERVOPACKs and converters.
3
3-17
3-18
3 Wiring and Connection
3.1.4 General Precautions for Wiring
3.1.4
General Precautions for Wiring
• Use a molded-case circuit breaker (1QF) or fuse to protect the main circuit.
The SERVOPACKs and converters connect directly to a commercial power supply;
They are not isolated through a transformer or other device.
Always use a molded-case circuit breaker (1QF) or fuse to protect the servo system from accidents involving different power system voltages or other accidents.
• Install a ground fault detector.
The SERVOPACKs and converters do not have a built-in protective circuit for grounding.
To configure a safer system, install a ground fault detector against overloads and short-circuiting, or install a ground fault detector combined with a molded-case circuit breaker.
• Do not turn the power ON and OFF more than necessary.
• Do not use a SERVOPACK or converter for applications that require the power to turn ON and OFF frequently. Such applications will cause elements in the SERVO-
PACK or converter to deteriorate.
• As a guideline, at least one hour should be allowed between the power being turned ON and OFF once actual operation has been started.
To ensure safe, stable application of the servo system, observe the following precautions when wiring.
• Use the specified connection cables. Use the connection cables specified in the Large-Capacity short as possible.
Σ -V Series
Product Catalog (No.: KAEP S800000 86). Design and arrange the system so that each cable will be as
• Use shielded twisted-pair cables or screened unshielded twisted-pair cables for I/O signal cables and encoder cables.
• Use the busbars that are included with the converter and connect the P and N terminals on the SERVOPACK and converter securely.
• The maximum cable length is 3 m for I/O signal cables, 50 m for connection cables for servomotor main circuit or encoder cables, and 10 m for control power supply cables to 400-V converters (+24 V, 0 V).
• Observe the following precautions when wiring the ground.
• Use a cable as thick as possible (at least 2.0 mm 2 ).
• Grounding to a resistance of 100 Ω or less for 200-V SERVOPACKs, 10 Ω or less for 400-V SERVO-
PACKs or converters is recommended.
• Be sure to ground at only one point.
• Ground the servomotor directly if the servomotor is insulated from the machine.
• The signal cable conductors are as thin as 0.2 mm 2 tension.
or 0.3 mm 2 . Do not impose excessive bending force or
3.1 Main Circuit Wiring
(1) Power Supply Capacities and Power Losses
The following table shows the power supply capacities and power losses of the SERVOPACKs and converters.
The values in the following table are for one combination of a SERVOPACK and converter. If there is more than one combination of a SERVOPACK and converter, find the total for the combinations that are used.
Main
Circuit
Power
Supply
Threephase
200 V
Threephase
400 V
Maximum
Applicable
Servomotor
Capacity
[kW]
22
30
37
30
37
55
Combination of
SERVOPACK and
Converter
SERVO-
PACK
Model:
SGDV-
Converter
Model:
SGDV-COA
121H 2BAA
161H
201H
3GAA
3GAA
750J
101J
131J
3ZDA
5EDA
5EDA
Power Supply
Capacity per
Combination
[kVA]
38
52
64
52
64
95
Output
Current
[Arms]
116
160
200
76
98
130
Main
Circuit
Power
Loss
[W]
1200
1540
1540
1020
1240
1590
Regenerative
Resistor
Power Loss
[W]
(480)
*1
(960)
*2
(960)
*3
(720)
*4
(960)
*5
(1440)
*6
Control
Circuit
Power
Loss
[W]
120
120
120
96
96
96
Total
Power
Loss
[W]
∗1.
This is the value for the JUSP-RA08-E regenerative resistor unit.
∗2.
This is the value for the JUSP-RA09-E regenerative resistor unit.
∗3.
This is the value for the JUSP-RA11-E regenerative resistor unit.
∗4.
This is the value for the JUSP-RA13-E regenerative resistor unit.
∗5.
This is the value for the JUSP-RA14-E regenerative resistor unit.
∗6.
This is the value for the JUSP-RA16-E regenerative resistor unit.
(2) How to Select Molded-case Circuit Breaker and Fuse Capacities
The following table shows the current capacities and inrush current of the SERVOPACKs and converters.
Use these values as a basis for selecting the molded-case circuit breaker and fuse. If there is more than one combination of a SERVOPACK and converter, find the total for the combinations that are used.
1320
1660
1660
1116
1336
1686
Main
Circuit
Power
Supply
Threephase
200 V
Threephase
400 V
Maximum
Applicable
Servomotor Capacity
[kW]
Combination of
SERVOPACK and
Converter
SERVOPACK Converter
Model: SGDV-
Model:
SGDV-
COA
22 121H 2BAA
Power
Supply
Capacity per
Combination
[kVA]
Current Capacity Inrush Current
Main
Circuit
[Arms]
Control
Circuit
[Arms]
Main
Circuit
[A0-p]
Control
Circuit
[A0-p]
Rated voltage
Fuse
[V]
Circuit
Breaker
[V]
30
37
30
37
55
161H
201H
750J
101J
131J
3GAA
3GAA
3ZDA
5EDA
5EDA
38
52
64
52
64
95
127
174
214
87
107
159
1.2
*1
1.2
*1
1.2
*1
4
*2
4
*2
4
*2
163
163
163
16
16
16
170 –
170 –
170 –
250
600
240
480
∗1.
Input voltage of 200 VAC
∗2.
Input voltage of 24 VDC
Note 1. The rated input current of the SERVOPACK is the nominal value at the rated load.
Select the appropriate capacity in accordance with the specified derating.
Cutoff characteristics (25 ° C): 300% five seconds min.
2. To comply with the low voltage directive, connect a fuse to the input side. Select the fuse or molded-case circuit breaker for the input side from among models that are compliant with UL standards.
The table above also provides the nominal values of current capacity and inrush current. Select a fuse and a molded-case circuit breaker which meet the cutoff characteristics shown below.
• Main circuit, control circuit: No breaking at three-times the current values of the table for 5 s.
• Inrush current: No breaking at the same current values of the table for 20 ms.
3
3-19
3-20
3 Wiring and Connection
3.1.5 Discharging Time of the Main Circuit’s Capacitor
3.1.5
Discharging Time of the Main Circuit’s Capacitor
The following table shows the discharging time of the main circuit’s capacitor.
Input Voltage
Three-phase
200 VAC
Three-phase
400 VAC
Combinations
SERVOPACK Model:
SGDV-
Converter Model:
SGDV-COA
121H
161H
201H
750J
101J
131J
2BAA
3GAA
3GAA
3ZDA
5EDA
5EDA
Discharging Time
[min.]
20
25
30
5
10
10
3.2 Connecting the Converter to the SERVOPACK
3.2
Connecting the Converter to the SERVOPACK
3.2.1
Connecting the Connectors
Connect CN901 and CN103 on the SERVOPACK and converter as shown in the following figure.
Converter
SERVOPACK M-II
CN103: Control power supply input connector
24-VDC control power supply cable
I/O signal connection cable
CN901: I/O signal connector between the SERVOPACK and converter
Cable Name Cable Model
IO signal connection cable JZSP-CVI02-A4-E
24-VDC control power supply cable
JZSP-CVG00-A4-E
Cable Length
0.4 m
0.4 m
Description
This cable connects the CN901 connectors on the SERVOPACK and converter.
This cable connects the CN103(CN104) connectors on the SERVOPACK and converter.
3.2.2
Interconnecting Terminals
Use the busbars that are provided with the converter to connect the P and N terminals between the SERVO-
PACK and the converter.
The busbars are different for different converter models.
(1) SGDV-COA2BAA, -COA3ZDA Converters
Attach the busbars as shown in the following figure.
Note: The shapes of the ends of the busbars are different for the SERVOPACK and converter connections and for the P terminal and N terminal connections.
3
3-21
3-22
3 Wiring and Connection
3.2.2 Interconnecting Terminals
Converter’s P terminal
Converter’s N terminal
M-II
SERVOPACK’s P terminal
SERVOPACK’s N terminal
(2) SGDV-COA3GAA, -COA5EDA Converters
The busbars can be connected in any direction.
M-II
3.3 I/O Signal Connections
3.3
I/O Signal Connections
This section describes the names and functions of I/O signals (CN1). Also connection examples by control method are shown.
The number of pins on the CN1 connector is different on a large-capacity Σ -V SERVO-
PACK (50 pins) and a standard Σ -V SERVOPACK (26 pins). If you are using both types of SERVOPACK, use the correct connector model numbers when ordering and the correct signal assignments.
3.3.1
I/O Signal (CN1) Names and Functions
The following table shows the names and functions of I/O signals (CN1).
(1) Input Signals
Signal Pin No.
Name Function
Reference
Section
P-OT
(/SI2)
N-OT
(/SI3)
/DEC
(/SI1)
/EXT 1
(/SI4)
/EXT 2
(/SI5)
/EXT 3
(/SI6)
42
43
41
44
45
46
Forward run prohibited,
Reverse run prohibited
Homing deceleration switch signal
External latch signal 1
External latch signal 2
External latch signal 3
With overtravel prevention: Stops servomotor when movable part travels beyond the allowable range of motion.
Connects the deceleration limit switch for homing.
Connects the external signals that latch the current feedback pulse counter.
/SI0
+24VIN 47
BAT (+)
BAT (-)
40
21
22
/P-CL
/N-CL
/DBANS
Can be allocated
General-purpose input signal
Control power supply for sequence signal
Battery (
Battery (
+
−
) input signal
) input signal
Used for general-purpose input.
Monitored in the I/O monitor field of MECHATROLINK.
Control power supply input for sequence signals.
Allowable voltage fluctuation range: 11 to 25 V
Note: The 24 VDC power supply is not included.
Connecting pin for the absolute encoder backup battery.
Do not connect when the encoder cable with the battery case is used.
Forward external torque limit
Reverse external torque limit
Dynamic brake answer signal
The allocation of an input signal to a pin can be changed in accordance with the function required.
4.3.1
−
−
−
3.5.1
3.7.2
4.7.1
−
Note 1. The allocation of the input signals (/SI0 to /SI6) can be changed. For details, refer to 3.4.1 Input Signal Allocations .
2. If the Forward run prohibited/ Reverse run prohibited function is used, the SERVOPACK or converter is stopped by software controls, not by electrical or mechanical means. If the application does not satisfy the safety requirements, add an external circuit for safety reasons as required.
(2) Output Signals
Signal Pin No.
ALM+
ALM-
31
32
Name Function
Servo alarm output signal
Turns OFF when an error is detected.
Reference
Section
−
3
3-23
3-24
3 Wiring and Connection
3.3.2 Safety Function Signal (CN8) Names and Functions
Signal Pin No.
Name Function
(cont’d)
Reference
Section
/BK+
(/SO1+)
/BK-
(/SO1-)
/SO2+
/SO2-
/SO3+
/SO3-
25
26
27
28
29
30
Brake interlock signal
General-purpose output signal
Controls the brake. The brake is released when the signal turns ON.
Allocation can be changed to general-purpose output signals
(/SO1+, /SO1-).
Used for general-purpose output.
Note: Set the parameter to allocate a function.
4.3.2
−
/COIN
/V-CMP
/TGON
/S-RDY
/CLT
/VLT
/WARN
/NEAR
Can be allocated
Positioning completion
Speed coincidence detection
Rotation detection
Servo ready
Torque limit
Speed limit detection
Warning
Near
The allocation of an output signal to a pin can be changed in accordance with the function required.
−
PAO
/PAO
PBO
/PBO
PCO
/PCO
33
34
35
36
19
20
Phase-A signal
Phase-B signal
Phase-C signal
Encoder output pulse signals for two-phase pulse train with
90 ° phase differential
Origin pulse output signal
4.4.4
4.7.5
SG
FG
1
Shell
Signal ground
Frame ground
Connects to the 0 V pin on the control circuit of the host controller.
Connected to frame ground if the shielded wire of the I/O signal cable is connected to the connector shell.
−
−
–
2 to 18
23
24
37 to 39
48 to 50
– Do not use these pins.
−
Note: The allocation of the output signals (/SO1 to /SO3) can be changed. For details, refer to 3.4.2 Output Signal Allocations.
3.3.2
Safety Function Signal (CN8) Names and Functions
The following table shows the terminal layout of safety function signals (CN8).
–
–
Signal Name
/HWBB1+
/HWBB1-
/HWBB2+
/HWBB2-
EDM1+
EDM1-
Pin No.
4
3
6
5
8
7
1
*
2
*
Hard wire baseblock input 1
Hard wire baseblock input 2
Monitored circuit status output 1
–
–
Function
For hard wire baseblock input.
Baseblock (motor current off) when
OFF.
ON when the /HWBB1 and the
/HWBB2 signals are input and the
SERVOPACK enters a baseblock state.
∗ Do not use pins 1 and 2 because they are connected to the internal circuits.
3.3 I/O Signal Connections
3.3.3
Example of I/O Signal Connections
The following diagram shows a typical connection example.
Photocoupler output
Max. operating voltage: 30 VDC
Max. output current: 50 mA DC
SERVOPACK
CN1
Control power for sequence signals
∗
3.
Homing deceleration switch
(Decelerated when ON)
+24 V +24VIN
/DEC
47
41
3.3 k
Ω
Forward run prohibited
(Prohibited when OFF)
P-OT 42
Reverse run prohibited
(Prohibited when OFF)
N-OT 43
External latch signal 1
(Latched when ON)
/EXT1 44
External latch signal 2
(Latched when ON)
/EXT2
45
External latch signal 3
(Latched when ON)
/EXT3 46
General-purpose
Backup battery
∗
2.
(2.8 to 4.5 V)
/SI0
BAT+
BAT-
40
21
22
Switch
∗
1.
/HWBB1+
CN8
4
24 V
Fuse
/HWBB13
Safety function device*4
/HWBB2+ 6
0 V
/HWBB25
8
7
EDM1+
EDM1-
SERVOPACK
Connector shell
FG Connect shield to connector shell.
MECHA
31
32
ALM+
ALM-
Servo alarm output
(OFF for an alarm)
25
26
27
SO1+ / BK+
SO1- / BK-
/SO2+
Brake
(Brake released when open)
28
29
30
/SO2-
/SO3+
/SO3-
33
34
PAO
/PAO
∗
5
Encoder output pulse phase A
35
36
PBO
/PBO
∗
5
Encoder output pulse phase B
Applicable line receiver:
SN75ALS175 or MC3486 manufactured by Texas
Instruments or the equivalent
19
20
PCO
/PCO
∗
5
Encoder output pulse phase C
1 SG
∗1.
represents twisted-pair wires.
∗2.
Connect when using an absolute encoder. When the encoder cable with the battery case is connected, do not connect a backup battery.
∗3.
The 24-VDC power supply is not included. Use a 24-VDC power supply with double insulation or reinforced insulation.
∗4.
When using the safety function, a safety function device must be connected and the wiring that is necessary to activate the safety function must be done to turn ON the servomotor power. When not using the safety function, use the
SERVOPACK with the Plug (provided as an accessory) inserted into the CN8.
∗5.
Always use line receivers to receive the output signals.
Note: The functions allocated to the input signals /DEC, P-OT, N-OT, /EXT1, /EXT2, and /EXT3 and the output signals
/SO1, /SO2, and /SO3 can be changed by using the parameters. Refer to 3.4.1 Input Signal Allocations and 3.4.2
Output Signal Allocations .
The number of pins on the CN1 connector is different on a large-capacity Σ -V SERVO-
PACK (50 pins) and a standard Σ -V SERVOPACK (26 pins). If you are using both types of SERVOPACK, use the correct connector model numbers when ordering and the correct signal assignments.
3
3-25
3-26
3 Wiring and Connection
3.4.1 Input Signal Allocations
3.4
I/O Signal Allocations
This section describes the I/O signal allocations.
3.4.1
Input Signal Allocations
• Inverting the polarity of the forward run prohibited and reverse run prohibited signals from the factory setting will prevent the overtravel function from working in case of signal line disconnections or other failures.
If this setting is absolutely necessary, check the operation and confirm that there are no safety problems.
• When two or more signals are allocated to the same input circuit, input signal level is valid for all allocated signals, resulting in an unexpected machine operation.
Input signals are allocated as shown in the following table.
Refer to the Interpreting the Input Signal Allocation Tables and change the allocations accordingly.
<Interpreting the Input Signal Allocation Tables>
Level at which input signal allocations are valid.
The parameter set values to be used are shown.
Signals are allocated to CN1 pins according to the selected set values.
Values in cells in bold lines are the factory settings.
Forward Run Prohibited
Pn50A.3
H
L
CN1 Pin Numbers
Input Signal Names and Parameters
Validity
Level
Input
Signal
P-OT
/P-OT
40 41 42 43 44 45 46
0
9
1
A
2
B
3
C
4
D
5
E
6
F
Connection Not
Required
(SERVOPACK judges the connection)
Always
ON
Always
OFF
7 8
If always ON (7) or always OFF (8) is set, signals will be processed in the SERVOPACK, which will eliminate the need for wiring changes.
Forward Run Prohibited
Pn50A.3
Reverse Run Prohibited
Input Signal Names and Parameters
Validity
Level
Input
Signal
Pn50B.0
H
L
H
L
P-OT
/P-OT
N-OT
/N-OT
CN1 Pin Numbers
40 41 42 43 44 45 46
0
9
0
0
1
A
1
A
2
B
2
B
3
C
3
C
4
D
4
D
5
E
5
E
6
F
6
F
Connection Not
Required
(SERVOPACK judges the connection)
Always
ON
Always
OFF
7
7
8
8
3.4 I/O Signal Allocations
Input Signal Names and Parameters
Forward External
Torque Limit
Pn50B.2
Reserve External
Torque Limit
Pn50B.3
Homing Deceleration
LS
Pn511.0
External Latch Signal 1
Pn511.1
External Latch Signal 2
Pn511.2
External Latch Signal 3
Pn511.3
DB Answer
Pn515.2
H
H
L
H
L
H
L
H
L
L
H
L
L
Validity
Level
Input
Signal
CN1 Pin Numbers
/P-CL
P-CL
/N-CL
N-CL
/DEC
DEC
EXT1
/EXT1
EXT2
/EXT2
EXT3
/EXT3
/DBANS 0
9
*
*
*
*
*
*
9
0
0
9
0
40 41 42 43 44 45 46
A
*
*
*
*
*
*
A
1
1
A
1
1
2
B
2
B
2
B
*
*
*
*
*
*
2
3
C
3
C
3
C
*
*
*
*
*
*
3
4
D
4
D
4
D
D
4
D
4
D
4
4 5 6
E
E
5
E
5
E
5
E
5
5
E
5
F
F
6
F
6
F
6
F
6
6
F
6
(cont’d)
Connection Not
Required
(SERVOPACK judges the connection)
Always
ON
Always
OFF
7
7
7
7
7
7
8
8
8
8
8
8
7 8
H DBANS 9 A B C D E F
∗ These pins cannot be used.
Note: The factory settings of the parameters in a large-capacity Σ -V SERVOPACK are not all the same as those for a standard Σ -V SERVOPACK. Make sure that you consider any differences in the factory settings if you copy the parameters from a standard Σ -V SERVOPACK to a large-capacity Σ -V SERVOPACK.
3.4.2
Output Signal Allocations
• The signals not detected are considered as " Invalid.
" For example, Positioning Completion (/COIN) signal in speed control is " Invalid.
"
• Inverting the polarity of the brake signal (/BK), i.e. positive logic, will prevent the holding brake from working in case of its signal line disconnection.
If this setting is absolutely necessary, check the operation and confirm that there are no safety problems.
• When two or more signals are allocated to the same output circuit, a signal is output with OR logic circuit.
Output signals are allocated as shown in the following table.
Refer to the Interpreting the Output Signal Allocation Tables and change the allocations accordingly.
<Interpreting the Output Signal Allocation Tables>
3
3-27
3-28
3 Wiring and Connection
3.4.2 Output Signal Allocations
MECHA
The parameter set values to be used are shown.
Signals are allocated to CN1 pins according to the selected set values.
Values in cells in bold lines are the factory settings.
Output Signal Names and Parameters
Brake
Pn50F.2
Output Signal
/BK
25 (26)
1
CN1 Pin Numbers
27 (28)
2
29 (30)
3
㧔
Invalid not use
0
㧕
Output Signal Names and Parameters
Positioning Completion
Pn50E.0
Speed Coincidence
Detection
Pn50E.1
Rotation Detection
Pn50E.2
Servo Ready
Pn50E.3
Torque Limit Detection
Pn50F.0
Speed Limit Detection
Pn50F.1
Brake
Pn50F.2
Warning
Pn50F.3
Near
Pn510.0
Pn512.0=1
Pn512.1=1
Pn512.2=1
Output Signal
/COIN
/V-CMP
/TGON
/S-RDY
/CLT
/VLT
/BK
/WARN
/NEAR
25/ (26)
1
1
1
1
1
1
1
1
1
CN1 Pin Numbers
27/ (28)
2
2
2
2
2
2
2
2
2
Polarity inversion of CN1-25(26)
Polarity inversion of CN1-27(28)
Polarity inversion of CN1-29(30)
29/ (30)
3
3
3
3
3
3
3
3
3
Invalid
(not use)
0
0
0
0
0
0
0
0
0
0
(Not invert at factory setting)
3.5 Examples of Connection to Host Controller
3.5
Examples of Connection to Host Controller
This section shows examples of SERVOPACK I/O signal connection to the host controller.
3.5.1
Sequence Input Circuit
(1) Photocoupler Input Circuit
CN1 connector terminals 40 to 47 are explained below.
The sequence input circuit interface is connected through a relay or open-collector transistor circuit. When connecting through a relay, use a low-current relay. If a low-current relay is not used, a faulty contact may result.
Open-collector Circuit Example
24 VDC
Relay Circuit Example
SERVOPACK
+24 VIN
3.3 k
Ω
/DEC, etc.
24 VDC
SERVOPACK
+24 VIN
3.3 k
Ω
/DEC, etc.
Note: The 24 VDC external power supply capacity must be 50 mA minimum.
The SERVOPACK’s input circuit uses bidirectional photocoupler. Select either the sink circuit or the source circuit according to the specifications required for each machine.
Note:
•
The connection example in 3.3.3
shows sink circuits.
• The ON/OFF polarity differs between when a sink circuit is connected and when a source circuit is connected.
Sink Circuit Source Circuit
24 V
+
− SERVOPACK input
24 V
+
− SERVOPACK input
Signal
ON
OFF
Input Signal Polarities
Level
Voltage
Level
Low (L) level
High (H) level
0 V
24 V
Contact
Close
Open
Signal
ON
OFF
Input Signal Polarities
Level
Voltage
Level
High (H) level
Low (L) level
24 V
0 V
Contact
Close
Open
3
3-29
3-30
3 Wiring and Connection
3.5.1 Sequence Input Circuit
(2) Safety Input Circuit
As for wiring input signals for safety function, input signals make common 0 V. It is necessary to make an input signal redundant.
Input Signal Connection Example
SERVOPACK
CN8
24-V power supply
Switch
Fuse
/HWBB1+ 4 3.3 k
Ω
/HWBB13
3.3 k Ω
/HWBB2+
/HWBB2-
6 3.3 k Ω
5
3.3 k Ω
3.5 Examples of Connection to Host Controller
3.5.2
Sequence Output Circuit
Three types of SERVOPACK output circuit are available.
Incorrect wiring or incorrect voltage application to the output circuit may cause short-circuit.
If a short-circuit occurs as a result of any of these causes, the holding brake will not work. This could damage the machine or cause an accident resulting in death or injury.
(1) Photocoupler Output Circuit
Photocoupler output circuits are used for servo alarm (ALM), servo ready (/S-RDY), and other sequence output signal circuits. Connect a photocoupler output circuit through a relay or line receiver circuit.
Relay Circuit Example
SERVOPACK
5 to 24 VDC
Relay
Line Receiver Circuit Example
SERVOPACK
5 to 12 VDC
0 V
Note: The maximum allowable voltage and the allowable range of current capacity for photocoupler output circuits are as follows.
• Voltage: 30 VDC
• Current: 5 to 50 mA DC
(2) Line Driver Output Circuit
CN1 connector terminals, 33-34 (phase-A signal), 35-36 (phase-B signal), and 19-20 (phase-C signal) are explained below.
These terminals output the following signals via the line-driver output circuits.
• Output signals for which encoder serial data is converted as two phases pulses (PAO, /PAO, PBO, /PBO)
• Origin pulse signals (PCO, /PCO)
Connect the line-driver output circuit through a line receiver circuit at the host controller.
Line Receiver Circuit Example
Applicable line receiver:
SN75ALS175 or the equivalent
220 to
470
Ω
3
3-31
3-32
3 Wiring and Connection
3.5.2 Sequence Output Circuit
(3) Safety Output Circuit
The external device monitor (EDM1) for safety output signals is explained below.
A configuration example for the EDM1 output signal is shown in the following diagram.
SERVOPACK
Host controller
CN8
8 EDM1+
24 V Power Supply
7 EDM1-
0 V
Specifications
Type
Output
Signal Name
EDM1
Pin No.
CN8-8
CN8-7
ON
Output
Status
OFF
Meaning
Both the /HWBB1 and /HWBB2 signals are working normally.
The /HWBB1 signal, the /HWBB2 signal, or both are not working normally.
Electrical characteristics of EDM1 signal are as follows.
Items
Maximum Allowable Voltage
Maximum Current
Maximum Voltage Drop at ON
Maximum Delay Time
Characteristic
30 VDC
50 mADC
1.0 V
20 ms
Remarks
−
−
Voltage between EDM1+ to EDM1- at current is 50 mA.
Time from the change in /HWBB1 or /HWBB2 until the change in EDM1.
3.6 Wiring MECHATROLINKII Communications
3.6
Wiring MECHATROLINK-
II
Communications
The following diagram shows an example of connections between a host controller and a SERVOPACK using
MECHATROLINK-II communications cables (CN6A, CN6B).
DC24V
DC 0V
MP2300
YASKAWA
RDY
ALM
TX
218IF-01
RUN RUN
ERR
BAT
STRX
TX
ERR
COL
RX
STOP
SUP
INT
CNFG
MON
TEST
ޓ SW1
OFF
ޓ
ON
INIT
TEST
OFF
PORT
ON
M-
I
/
II
BATTERY
10Base-T
L1
L2
M-II
Ln
Terminator
Note 1. The length of the cable between stations (L1, L2 ... Ln) must be 0.5 m or more.
2. The total cable length must be L1 + L2 ... + Ln ≤ 50.
3. When multiple SERVOPACKs are connected by MECHATROLINK-II communications cable, a terminator must be installed at the final SERVOPACK.
3
3-33
3-34
3 Wiring and Connection
3.7.1 Encoder Signal (CN2) Names and Functions
3.7
Encoder Connection
This section describes the encoder signal (CN2) names, functions, and connection examples.
3.7.1
Encoder Signal (CN2) Names and Functions
The following table shows the names and functions of encoder signals (CN2).
PG 5 V
PG 0 V
BAT (+)*
BAT (-)*
Signal Name
PS
/PS
Shield
3
4
1
2
5
6
Shell
Pin No.
Function
Encoder power supply +5 V
Encoder power supply 0 V
Battery (+)
Battery (-)
Serial data (+)
Serial data (-)
–
∗ These do not need to be connected for an incremental encoder.
3.7.2
Encoder Connection Examples
The following diagrams show connection examples of the encoder, the SERVOPACK, and the host controller.
(1) Incremental Encoder
Incremental encoder
∗
1
ENC
∗
2
PS
/PS
PG5V
PG0V
SERVOPACK
Phase A
Phase B
CN2
5
6
Phase C
1
2
Output line-driver SN75ALS174 manufactured by Texas
Instruments or the equivalent
CN1
33
34
35
36
19
20
0 V
CN1
1
PA O
/PAO
PBO
/PBO
PCO
/PCO
SG
∗
2
R
R
R
Host controller
Phase A
MEC
HA
Phase B
0 V
Phase C
FG
Connector shell
Shielded wire
Connector shell
Applicable line receiver: SN75ALS175 or MC3486 manufactured by Texas
Instruments, or the equivalent
R (terminating resistance): 220 to 470 Ω
∗1.
The pin arrangement for wiring connectors varies in accordance with the servomotor that is used.
∗2.
: represents shielded twisted-pair wires.
3.7 Encoder Connection
(2) Absolute Encoder
Absolute encoder
∗
1
ENC
∗
2
PS
/PS
SERVOPACK
Phase A
Phase B
CN2
5
6
Phase C
Output line-driver SN75ALS174 manufactured by Texas
Instruments or the equivalent
CN1
33
34
35
36
19
20
PAO
/PAO
PBO
/PBO
PCO
/PCO
1 SG
∗
2
R
R
R
Host controller
Phase A
Phase B
Phase C
MECHA
BAT(+)
BAT(-)
PG5 V
PG0 V
3
4
1
2
CN1
21
22
BAT (+)
BAT (-)
+
-
Battery
∗
3
FG
Connector shell
Connector shell
Applicable line receiver: SN75ALS175 or MC3486 manufactured by Texas
Instruments, or the equivalent
R (terminating resistance): 220 to 470
Ω
∗1.
The pin arrangement for wiring connectors varies in accordance with the servomotor that is used.
∗2.
: represents shielded twisted-pair wires.
0 V
∗3.
When using an absolute encoder, provide power by installing an encoder cable with a JUSP-BA01-E Battery Case or install a battery on the host controller.
3
3-35
3-36
3 Wiring and Connection
3.8.1 Selecting a Regenerative Resistor Unit
3.8
Selecting and Connecting a Regenerative Resistor Unit
The SERVOPACKs and converters do not contain a regenerative resistor. Select and connect a regenerative resistor unit and set the regenerative resistor capacity in Pn600 as described in this section.
For detailed specifications of the regenerative resistor units, refer to Large-Capacity Σ -V Series Catalog (No.:
KAEP S800000 86).
WARNING
• Be sure to connect the regenerative resistor unit correctly. Do not short-circuit between B1 and B2.
Doing so may result in fire or damage to the regenerative resistor unit, SERVOPACK, or converter or other devices.
3.8.1
Selecting a Regenerative Resistor Unit
(1) Using a Regenerative Resistor Unit Specified by Yaskawa
The regenerative resistor units specified by Yaskawa are listed in the following table. You must acquire the regenerative resistor units separately.
If you use a regenerative resistor unit specified by Yaskawa, use it only in one of the combinations that are given in the following table.
Main Circuit
Power Supply
Voltage
SERVO-
PACK
Model
SGDV-
Converter
Model
SGDV-COA
Model of Applicable
Regenerative
Resistor Unit
Resistance
( Ω )
Specifications
Three-phase
200 V
Three-phase
400 V
121H
161H
201H
750J
101J
131J
2BAA
3GAA
3ZDA
5EDA
JUSP-RA08-E
JUSP-RA09-E
JUSP-RA11-E
JUSP-RA13-E
JUSP-RA14-E
JUSP-RA16-E
2.4
1.8
1.6
6.7
5
3.8
Four 0.6Ω (600-W) resistors connected in series
Two sets of four 0.9Ω (600-W) resistors connected in series are connected in parallel.
Eight 0.2Ω (600-W) resistors connected in series
Three sets of two 10Ω (600-W) resistors connected in series are connected in parallel.
Four sets of two 10Ω (600-W) resistors connected in series are connected in parallel.
Four sets of three 5Ω (600-W) resistors connected in series are connected in parallel.
(2) Using a Non-Specified Regenerative Resistor Unit
If you use non-specified regenerative resistor units, contact your Yaskawa representative or the sales department for more details.
If you use a non-specified regenerative resistor unit, we recommend that you use a regenerative resistor unit with a thermal switch for safety.
3.8 Selecting and Connecting a Regenerative Resistor Unit
3.8.2
Connecting a Regenerative Resistor Unit
Connect the B1 terminals and connect the B2 terminals between the converter and regenerative resistor unit.
Connect them as shown in the following figures.
(1) Converter Model: SGDV-COA2BAA, -COA3ZDA
M-II Regenerative Resistor Unit
JUSP-RA -E
Converter SERVOPACK
B1 B2
B1 B2
(2) Converter Model: SGDV-COA3GAA, -COA5EDA
M-II Regenerative Resistor Unit
JUSP-RA -E
Converter SERVOPACK
B1B2
B1B2
3
3-37
3-38
3 Wiring and Connection
3.8.3 Setting Regenerative Resistor Capacity
3.8.3
Setting Regenerative Resistor Capacity
(1) Using a Regenerative Resistor Unit Specified by Yaskawa
Using a Specified Combination
If you use a regenerative resistor unit specified by Yaskawa in one of the specified combinations, use the factory setting for Pn600.
Using a Non-Specified Combination
If you use a non-specified combination, refer to (2) Using a Non-Specified Regenerative Resistor Unit .
(2) Using a Non-Specified Regenerative Resistor Unit
If you use a non-specified regenerative resistor unit or if you use a regenerative resistor unit specified by
Yaskawa but do not use it in the specified combination, set the capacity of the resistor in Pn600 (Regenerative
Resistor Capacity).
WARNING
• If you set Pn600 to 0 when a non-specified regenerative resistor unit is connected or when a regenerative resistor unit specified by Yaskawa is connected in a non-specified combination, regenerative overload alarms (A.320) may not be detected. If the regenerative overload alarm (A.320) is not detected correctly, the regenerative resistor may be damaged and an injury or fire may result. Always set Pn600 to a suitable value.
Pn600
Regenerative Resistor Capacity
Setting Range Unit
Speed
Factory Setting
Position Torque
When Enabled
0 to SERVOPACK capacity
10 W 0 Immediately
Classification
Setup
Be sure to set the regenerative resistor capacity (Pn600) to a value that is in accordance with the allowable capacity of the actual regenerative resistor unit being used.
Note: If Pn600 is not set to the optimum value, alarm A.320 will occur.
The setting will vary with the cooling method of external regenerative resistor:
• For natural convection cooling: Set the value to a maximum 20% of the actually installed regenerative
resistor capacity (W).
• For forced convection cooling: Set the value to a maximum 50% of the actually installed regenerative
resistor capacity (W).
Example: Set 20 W (100 W × 20%) for the 100-W regenerative resistor unit with natural convection
cooling method:
Pn600 = 2 (unit: 10 W)
When the regenerative resistor unit for power are used at the rated load ratio, the resistor temperature increases to between 200 ° C and 300 ° C. The resistors must be used at or below the rated values. Check with the manufacturer for the resistor’s load characteristics.
3.8 Selecting and Connecting a Regenerative Resistor Unit
3.8.4
Installation Standards
Observe the following installation standards when you use a regenerative resistor unit specified by Yaskawa.
Provide at least 70 mm on each side of the unit and at least 200 mm at both the top and bottom of the unit to enable fan and natural convection cooling.
Up
Mounting direction
70 min.
70 min.
Units: mm
If you use a non-specified regenerative resistor unit, follow the specifications of the regenerative resistor unit when you install it.
3
3-39
3-40
3 Wiring and Connection
3.9.1 Selection
3.9
Selecting and Connecting a Dynamic Brake Unit
To use the dynamic brake (DB), externally connect a dynamic brake unit or dynamic brake resistor to the
SERVOPACK to process the dynamic braking energy.
Set Pn001 to n.
dynamic brake unit.
2 if you do not use the dynamic brake. In this case, it is not necessary to connect a
3.9.1
Selection
Use the following tables to select a dynamic brake unit or dynamic brake resistor.
(1) Using a Yaskawa Dynamic Brake Unit
Main Circuit
Power Supply
Voltage
Three-phase
200 V
SERVOPACK
Model:
SGDV-
Dynamic Brake
Unit Model
121H, 161H, 201H JUSP-DB02-E
Resistance
Specifications
(Star Wiring )
180 W, 0.3 Ω × 3
Three-phase
400 V
750J, 101J
131J
JUSP-DB04-E
JUSP-DB06-E
180 W, 0.8 Ω × 3
300 W, 0.8 Ω × 3
(2) Using a Dynamic Brake Resistor from Another Company
To order a dynamic brake unit, contact the manufacturer directly.
Dynamic Brake Contactor and
Surge Absorption Unit
Built into dynamic brake unit.
Main Circuit
Power Supply
Voltage
Three-phase
200 V
Three-phase
400 V
Model
GR series
Manufacturer
Required
Resistance
Japan Resistor Mfg. Co., Ltd.
0.3 Ω or greater
0.8 Ω or greater
Use the following dynamic brake contactors and surge absorption units.
Manufacturer Name
Contactor
Main circuit surge absorption unit
*
Head-on type
Side-on type
Coil surge absorption unit
Model
SC-4-1/G
Coil: 24 VDC
SZ-ZM1
SZ-ZM2
SZ-Z4
Fuji Electric Co., Ltd.
∗ Use either a head-on or side-on main circuit surge absorption unit.
3.9.2
Selecting the Cable for the Dynamic Brake Unit
Use one of the following cables to connect the dynamic brake unit or dynamic brake contactor to CN115 on the SERVOPACK.
Cable Model
Cable length
JZSP-CVD00-1A5-E 1.5 m
JZSP-CVD00-03-E 3 m
Cable End Processing on
Contact Coil End of Cable
Remarks
Crimp terminals are attached
(M3.5).
Red: Pin 1 (DB24)
Black: Pin 3 (DBON)
Manufacturer
Yaskawa Controls Co.,
Ltd.
3.9 Selecting and Connecting a Dynamic Brake Unit
3.9.3
Setting the Dynamic Brake Unit
Use the parameters shown in the tables here to make the settings for the following: the servomotor stopping method when the servo is turned OFF, the output signals used to control the dynamic brake contactor, and the capacity of the dynamic brake resistor in relation to whether or not a dynamic brake has been connected.
The servomotor stopping method when the servo is turned OFF is set with parameter Pn001.0.
Meaning
When
Enabled
Classification
Pn001
Parameter n.
0
[Factory setting] n.
1 n.
2
Stops servomotor by applying DB (dynamic brake).
Stops servomotor by applying DB and then releases DB.
Stops servomotor without applying DB by coasting to a stop.
After restart Setup
When using a dynamic brake resistor from a company other than Yaskawa, set Pn00D.1 (second digit) to 0 or
1 in accordance with the following table depending if an NO or NC contact is used.
When
Enabled
Classification
Pn00D
Parameter n.
0
[Factory setting] n.
1
Meaning
Enables the control of an NO contactor
(The dynamic brake is activated when current is supplied to the contactor coil.)
Enables the control of an NC contactor
(The dynamic brake is activated when current is not supplied to the contactor coil.)
After restart Setup
The dynamic brake resistor capacity is set with Pn601.
Pn601
Dynamic Brake Resistor Capacity
Setting Range Unit
Speed
Factory setting
Position Torque
When Enabled
0 to SERVOPACK capacity 10 W 0 Immediately
(1) Using a Yaskawa Dynamic Brake Unit
• Set Pn001 to n.
0.
• Not necessary to set Pn00D
• Set Pn601 to 0.
(2) Using a Dynamic Brake Resistors from Another Company
• Set Pn001 to n.
• Set Pn00D to either n.
0.
0D or n.
1 depending on your system.
• Set Pn601 to 20% of the resistor capacity of your dynamic brake.
Classification
Setup
If the setting of Pn601 is not correct, A.730 or A.731 (dynamic brake overloads) will not be detected correctly and there is a risk of equipment damage or fire.
3
(3) Not Using a Dynamic Brake
• Set Pn001 to n.
2.
• Not necessary to set Pn00D
• Set Pn601 to 0.
3-41
3-42
3 Wiring and Connection
3.9.4 Setting the Dynamic Brake Answer Function
3.9.4
Setting the Dynamic Brake Answer Function
With the dynamic brake answer function, you can use auxiliary contacts of the contactor that is used in the dynamic brake circuit and the dynamic brake answer signal (/DBANS) to detect welding or failure to operation.
To use the dynamic brake answer function, select a contactor that has auxiliary contacts.
Note: The dynamic brake answer function cannot be used with a Yaskawa dynamic brake unit because there are no auxiliary contacts on the contactor.
The dynamic brake answer signal is assigned with Pn515.2.
Parameter Meaning
When
Enabled
Classification n. 0 n. 1 n. 2 n. 3 n. 4 n. 5 n. 6
Detects dynamic brake (DB) contactor errors when the input signal of CN1-40 is ON (closed) while the DB is applied.
Detects DB contactor errors when the input signal of
CN1-41 is ON (closed) while the DB is applied.
Detects DB contactor errors when the input signal of
CN1-42 is ON (closed) while the DB is applied.
Detects DB contactor errors when the input signal of
CN1-43 is ON (closed) while the DB is applied.
Detects DB contactor errors when the input signal of
CN1-44 is ON (closed) while the DB is applied.
Detects DB contactor errors when the input signal of
CN1-45 is ON (closed) while the DB is applied.
Detects DB contactor errors when the input signal of
CN1-46 is ON (closed) while the DB is applied.
Pn515 n. 7 n. 8
[Factory setting]
Disables DB contactor error detection of DB answer signal 1.
After restart Setup n. 9 n. A n. B n. C n. D n. E n. F
Detects DB contactor errors when the input signal of
CN1-40 is OFF (open) while the DB is applied.
Detects DB contactor errors when the input signal of
CN1-41 is OFF (open) while the DB is applied.
Detects DB contactor errors when the input signal of
CN1-42 is OFF (open) while the DB is applied.
Detects DB contactor errors when the input signal of
CN1-43 is OFF (open) while the DB is applied.
Detects DB contactor errors when the input signal of
CN1-44 is OFF (open) while the DB is applied.
Detects DB contactor errors when the input signal of
CN1-45 is OFF (open) while the DB is applied.
Detects DB contactor errors when the input signal of
CN1-46 is OFF (open) while the DB is applied.
Example
If you use a dynamic brake contactor with NO contacts, input the dynamic brake answer signal (a signal from
NO auxiliary contacts) to CN1-45 and set Pn515 to n. E .
3.9 Selecting and Connecting a Dynamic Brake Unit
3.9.5
Installation Standards
Observe the following installation standards when you use a Yaskawa dynamic brake unit. Provide at least 70 mm on each side of the unit and at least 200 mm at both the top and bottom of the unit to enable fan and natural convection cooling.
Up
Mounting direction
70 min.
70 min.
SERVOPACK
Units: mm
If you use a dynamic brake resistor from a company other than Yaskawa, follow the specifications of the dynamic brake resistor when you install it.
3.9.6
Connections
(1) Using a Yaskawa Dynamic Brake Unit
A dynamic brake contactor is built into a Yaskawa dynamic brake unit.
The connections are shown in the following figure.
Note: The dynamic brake answer function (Pn515.2) cannot be used because there are no auxiliary contacts on the contactor.
Dynamic brake unit
24 V
DB
DU
DV
DW
CN115
DB24
DBON
DU
DV
DW
DB24
DBON
3
0 V
DB
3-43
3-44
3 Wiring and Connection
3.9.6 Connections
(2) Using a Dynamic Brake Resistor from Another Company
Using NO Contacts for the Dynamic Brake Contactor
SERVOPACK
CN1
47
24 V DB
For I/O power supply
24 V 0 V
45*
DU
DV
DW
CN115
DB24
DBON
Dynamic brake contactor
(Auxiliary contacts)
Dynamic brake resistor
0 V
DB
Main circuit surge absorption unit
Coil surge absorption unit
∗ The above figure is for using a dynamic brake contactor with NO contacts. The dynamic brake answer signal (a signal from NO auxiliary contacts) is input to CN1-45. To indicate an error if the input signal to CN1-45 turns OFF (open) while the dynamic brake is activated, the Pn515 parameter in the SERVOPACK must be set to n. E . If the dynamic brake answer signal is not used, Pn515 is set to n. 8 (default setting).
Note 1. If you assign more than one signal to the same input circuit, OR logic will be used and any of the input signals will cause the circuit to operate. This may result in unexpected operation.
2. The maximum current for DB24 and DBON is 300 mA.
3.9 Selecting and Connecting a Dynamic Brake Unit
Using NC Contacts for the Dynamic Brake Contactor
SERVOPACK
CN1
47
For I/O power supply
24 V 0 V
45*
Dynamic brake contactor
(Auxiliary contacts)
Dynamic brake resistor
DU
DV
DW
24 V DB
CN115
DB24
DBON
0 V
DB
Main circuit surge absorption unit
Coil surge absorption unit
∗ The above figure is for using a dynamic brake contactor with NC contacts. The dynamic brake answer signal (a signal from NC auxiliary contacts) is input to CN1-45. To indicate an error if the input signal to CN1-45 turns OFF (open) while the dynamic brake is activated, the Pn515 parameter in the SERVOPACK must be set to n. E dynamic brake answer signal is not used, Pn515 is set to n. 8 (default setting).
. If the
Note 1. If you assign more than one signal to the same input circuit, OR logic will be used and any of the input signals will cause the circuit to operate. This may result in unexpected operation.
2. The maximum current for DB24 and DBON is 300 mA.
If the coil current of NC dynamic brake contactors is 300 mA or higher, obtain an NO relay that can switch the contactor coil current and voltage and a power supply for the contactor coil.
SERVOPACK
CN1
47
45
DU
DV
DW
Power supply for contactor coil
NO relay
24V
DB
CN115
DB24
DBON
Power supply for contactor coil
For I/O power supply
24V
Dynamic brake contactor
(Auxiliary contacts)
0V
Dynamic brake resistor
Main circuit surge absorption unit
0V
DB
Coil surge absorption unit
3
3-45
3-46
3 Wiring and Connection
3.10.1 Wiring for Noise Control
3.10
Noise Control and Measures for Harmonic Suppression
This section describes the wiring for noise control and the DC reactor for harmonic suppression.
3.10.1
Wiring for Noise Control
• Because the SERVOPACKs and converters are designed as an industrial device, it provides no mechanism to prevent noise interference.
• The SERVOPACKs and converters use high-speed switching elements in the main circuit. Therefore peripheral devices may receive switching noise. If the equipment is to be used near private houses or if radio interference is a problem, take countermeasures against noise.
• If installation conditions by the EMC directive must be met, refer to 2.4 EMC Installation Conditions in Σ -V User’s Manual for Use with Large-Capacity Models Setup Rotational Motor (No.: SIEP S800000 89).
The SERVOPACKs and converters use microprocessors. Therefore it may receive switching noise from peripheral devices.
To prevent the noise from a SERVOPACK, converter, or the peripheral devices from causing a malfunction of any one of these devices, take the following precautions against noise as required.
• Position the input reference device and noise filter as close to a SERVOPACK or converter as possible.
• Always install a surge absorber in the relay, solenoid and electromagnetic contactor coils.
• Do not bundle or run the main circuit cables together with the I/O signal cables or the encoder cables in the same duct. Keep the main circuit cables separated from the I/O signal cables and the encoder cables with a gap of at least 30 cm.
• Do not share the power supply with an electric welder or electrical discharge machine. If the SERVOPACK is placed near equipment that generates high-frequency noise, install a noise filter on the input side of the main circuit power supply cables and control power supply cables, even if the same power supply is not used. As for the wiring of noise filter, refer to (1) Noise Filter shown below.
• Take the grounding measures correctly. As for the grounding, refer to (2) Correct Grounding.
3.10 Noise Control and Measures for Harmonic Suppression
(1) Noise Filter
The SERVOPACKs and converters have built-in microprocessors (CPUs), so protect them from external noise as much as possible by installing noise filters in the appropriate places.
The following is an example of wiring for noise control.
Noise filter
∗ 3
400 VAC
100/200 VAC
2.0 mm
2 min.
24-VDC power supply
+
-
L1
L2
L3
SERVOPACK and Converter
U
V
W
CN101
24 V
0 V
CN1
CN2
Servomotor
M
(FG)
ENC
2.0 mm 2 min.
Operating relay sequence
Signal generation circuit
(not included)
∗ 3
Noise filter
∗ 2
DC power supply
2.0 mm
2 min.
(Gronud plate)
∗ 1
Ground: Ground to an independent ground
∗1.
For ground wires connected to the ground plate, use a thick wire with a thickness of at least 2.0 mm
2 plain stitch cooper wire).
(preferably,
∗2.
should be twisted-pair wires.
∗3.
When using a noise filter, follow the precautions in 3.10.2 Precautions on Connecting Noise Filter .
(2) Correct Grounding
Take the following grounding measures to prevent the malfunction due to noise.
Grounding the Motor
Always connect servomotor frame terminal FG to the SERVOPACK ground terminal . Also be sure to ground the ground terminal .
If the servomotor is grounded via the machine, a switching noise current will flow from the main circuit of the
SERVOPACK and converter through the stray capacitance of the servomotor. To prevent the adverse effects of switching noise, always connect the ground terminal in the motor terminal box on the servomotor to the ground terminal on the SERVOPACK.
Noise on the I/O Signal Cable
If the I/O signal cable receives noise, ground the 0 V line (SG) of the I/O signal cable. If the servomotor main circuit cable is accommodated in a metal conduit, ground the conduit and its junction box. For all grounding, ground at one point only.
3
3-47
3-48
3 Wiring and Connection
3.10.2 Precautions on Connecting Noise Filter
3.10.2
Precautions on Connecting Noise Filter
Always observe the following installation and wiring instructions.
Some noise filters have large leakage currents. The grounding measures taken also affects the extent of the leakage current. If necessary, select an appropriate leakage current detector or leakage current breaker taking into account the grounding measures that are used and leakage current from the noise filter. Contact the manufacturer of the noise filter for details.
Do not put the input and output lines in the same duct or bundle them together.
Incorrect Correct
Noise
Filter
Ground plate
Noise
Filter
Ground plate
Noise
Filter
Noise
Filter
Ground plate Ground plate
Separate these circuits
Separate the noise filter ground wire from the output lines.
Do not accommodate the noise filter ground wire, output lines and other signal lines in the same duct or bundle them together.
Incorrect Correct
Noise
Filter
Noise
Filter
The ground wire can be close to input lines.
Ground plate Ground plate
3.10 Noise Control and Measures for Harmonic Suppression
Connect the noise filter ground wire directly to the ground plate.
Do not connect the noise filter ground wire to other ground wires.
Incorrect Correct
Noise
Filter
Converter SERVOPACK
P
N
P
N
Noise
Filter
Converter SERVOPACK
P P
N N
Shielded ground wire
Ground plate Ground plate
If a noise filter is located inside a control panel, first connect the noise filter ground wire and the ground wires from other devices inside the control panel to the ground plate for the control panel, then ground the plates.
Noise
Filter
Control Panel
Converter SERVOPACK
P
N
P
N
Converter SERVOPACK
P
N
P
N
Ground
Ground plate
3
3-49
3-50
3 Wiring and Connection
3.10.3 Connecting a Reactor for Harmonic Suppression
3.10.3
Connecting a Reactor for Harmonic Suppression
The converters have reactor connection terminals for power supply harmonic suppression that can be used as required.
Connect a reactor as shown in the following figure.
DC Reactor
Converter
DC reactor
1
2
400-VAC power supply
AC Reactor
AC reactor
U X
V
W
Y
Z
Converter
L1
L2
L3
Note 1. Connection terminals for DC reactor 1 and 2 are short-circuited at shipment. Remove the lead wire for short-circuit, and connect a DC reactor.
2. Reactors are not included. (Sold separately.)
3. To use the SERVOPACK with a DC reactor, use the terminals on the converters.
4
Operation
4.1 MECHATROLINKII Communications Settings . . . . . . . . . . . . . . . . . . . . 4-3
4.1.1 Setting Switches S2 and S3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
4.2 MECHATROLINKII Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
4.3 Basic Functions Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
4.3.1 Servomotor Rotation Direction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
4.3.2 Overtravel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
4.3.3 Software Limit Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
4.3.4 Holding Brakes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11
4.3.5 Stopping Servomotors after SV_OFF Command or Alarm Occurrence . . . . . . . . . . 4-16
4.3.6 Instantaneous Power Interruption Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-18
4.3.7 SEMI F47 Function (Torque Limit Function for Low DC Power Supply Voltage for Main Circuit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-19
4.3.8 Setting Motor Overload Detection Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-22
4.4 Trial Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24
4.4.1 Inspection and Checking before Trial Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24
4.4.2 Trial Operation via MECHATROLINKII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-25
4.4.3 Electronic Gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-26
4.4.4 Encoder Output Pulses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-29
4.4.5 Setting Encoder Output Pulse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-30
4.5 Test Without Motor Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-31
4.5.1 Motor Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-31
4.5.2 Motor Position and Speed Responses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-32
4.5.3 Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-33
4.5.4 Digital Operator Displays during Testing without Motor . . . . . . . . . . . . . . . . . . . . . . . 4-34
4.6 Limiting Torque . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-35
4.6.1 Internal Torque Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-35
4.6.2 External Torque Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-36
4.6.3 Checking Output Torque Limiting during Operation . . . . . . . . . . . . . . . . . . . . . . . . . 4-37
4
4-1
4-2
4 Operation
4.7 Absolute Encoders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-38
4.7.1 Connecting the Absolute Encoder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-39
4.7.2 Absolute Data Request (SENS ON Command) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-41
4.7.3 Battery Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-42
4.7.4 Absolute Encoder Setup and Reinitialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-44
4.7.5 Absolute Data Reception Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-46
4.7.6 Multiturn Limit Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-50
4.7.7 Multiturn Limit Disagreement Alarm (A.CC0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-51
4.7.8 Absolute Encoder Origin Offset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-52
4.8 Other Output Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-53
4.8.1 Servo Alarm Output Signal (ALM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-53
4.8.2 Warning Output Signal (/WARN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-53
4.8.3 Rotation Detection Output Signal (/TGON) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-54
4.8.4 Servo Ready Output Signal (/S-RDY) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-54
4.8.5 Speed Coincidence Output Signal (/V-CMP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-55
4.8.6 Positioning Completed Output Signal (/COIN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-56
4.8.7 Positioning Near Output Signal (/NEAR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-57
4.8.8 Speed Limit Detection Signal (/VLT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-58
4.9 Safety Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-60
4.9.1 Hard Wire Base Block (HWBB) Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-60
4.9.2 External Device Monitor (EDM1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-66
4.9.3 Application Example of Safety Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-68
4.9.4 Confirming Safety Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-69
4.9.5 Connecting a Safety Function Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-69
4.9.6 Precautions for Safety Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-70
4.1 MECHATROLINKII Communications Settings
4.1
MECHATROLINK-
II
Communications Settings
This section describes the switch settings necessary for MECHATROLINK-II communications.
4.1.1
Setting Switches S2 and S3
The S3 DIP switch is used to make the settings for MECHATROLINK-II communications.
The station address is set using the rotary switch (S2) and the DIP switch (S3).
M-II
S2
D
C
E
B
A
F
9
0
8
1
2
7
3
4
6
5
POWER LED
S3
ON
OFF
1 2 3 4 ᴾ
Seven-segment
LED display
(1) Settings for the S3 DIP Switch
The following table shows the settings of the DIP switch (S3).
SW2 Function
Pin 1 Sets the baud rate.
Pin 3 Sets the station address.
Pin 4 Reserved. (Do not change.)
Setting Description
OFF 4 Mbps (MECHATROLINK-I)
ON 10 Mbps (MECHATROLINK-II)
OFF 17 bytes
ON 32 bytes
OFF Station address = 40H + S2
ON Station address = 50H + S2
OFF −
Factory setting
ON
ON
OFF
OFF
• When connecting to a MECHATROLINKI network, turn OFF pins 1 and 2.
• When using a MECHATROLINKI network (Baud rate: 4 Mbps), the settings for the number of transmission bytes is disabled and the number of transmission bytes is always 17.
4
4-3
4-4
4 Operation
4.1.1 Setting Switches S2 and S3
(2) Setting the Station Address
The following table lists the possible settings of the rotary switch (S2) and the DIP switch (S3) that can be combined to form a station address.
D
E
F
9
A
7
8
B
C
2
3
0
1
4
5
6
The factory setting for the station address is 41H (S3 = OFF, S2 = 1).
S2
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Bit 3 of S3
OFF
OFF
OFF
OFF
OFF
47H
48H
49H
4AH
4BH
4CH
4DH
4EH
4FH
43H
44H
45H
46H
Station Address
Disabled
41H
42H
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
Bit 3 of S3
ON
ON
ON
D
E
F
9
A
7
8
B
C
2
3
0
1
4
5
6
S2
57H
58H
59H
5AH
5BH
5CH
5DH
5EH
5FH
53H
54H
55H
56H
Station Address
50H
51H
52H
• Turn the power OFF and then ON again to validate the new settings.
4.2
MECHATROLINK-
II
Commands
For information on the MECHATROLINK-II commands, refer to
TROLINK-II Commands (No.: SIEP S800000 54).
Σ -V Series User’s Manual MECHA-
4.3 Basic Functions Settings
4.3
Basic Functions Settings
4.3.1
Servomotor Rotation Direction
The servomotor rotation direction can be reversed with parameter Pn000.0 without changing the polarity of the speed/position reference. This causes the rotation direction of the servomotor to change, but the polarity of the signal, such as encoder output pulses, output from the SERVOPACK does not change. (refer to 4.4.4
Encoder Output Pulses )
The standard setting for forward rotation is counterclockwise (CCW) as viewed from the load end of the servomotor.
Pn000
Parameter
Forward/
Reverse
Reference
Direction of Motor Rotation and Encoder Output Pulse
Applicable
Overtravel (OT) n.
0
Sets CCW as forward direction.
[Factory setting]
Forward
Reference
Reverse
Reference
CCW
Motor speed
+ Torque reference Encoder output pulse
Motor speed
Time
PAO
PBO Phase B advanced
CW
+ Motor speed
Torque reference
Time
Encoder output pulse
PAO
Phase A advanced
PBO
Motor speed n.
1
Sets CW as forward direction.
(Reverse Rotation
Mode)
Forward
Reference
Reverse
Reference
CW
CCW
+
Motor speed
Torque reference
Motor speed
Encoder output pulse
Time
PAO
PBO Phase B advanced
+
Motor speed
Torque reference
Time
Encoder output pulse
PAO
PBO
Phase A advanced
Motor speed
Note: SigmaWin+ trace waveforms are shown in the above table.
P-OT
N-OT
P-OT
N-OT
4
4-5
4-6
4 Operation
4.3.2 Overtravel
4.3.2
Overtravel
The overtravel limit function forces movable machine parts to stop if they exceed the allowable range of motion and turn ON a limit switch.
For rotating application such as disc table and conveyor, overtravel function is not necessary. In such a case, no wiring for overtravel input signals is required.
CAUTION
• Installing limit switches
For machines that move using linear motion, connect limit switches to P-OT and N-OT of CN1 as shown below to prevent machine damage. To prevent a contact fault or disconnection from causing accidents, make sure that the limit switches are normally closed.
Forward direction
Servomotor
Limit switch
SERVOPACK
Limit switch
N-OT
CN1
43
P-OT
42
• Axes to which external force is applied in overtravel
Vertical axes:
Occurrence of overtravel may cause a workpiece to fall, because the /BK signal is on, that is when the brake is released. Set the parameter (Pn001 = n.
1 ) to bring the servomotor to zero clamp state after stopping to prevent a workpiece from falling.
Other axes to which external force is applied:
Overtravel will bring about a baseblock state after the servomotor stops, which may cause the servomotor to be pushed back by the load’s external force. To prevent this, set the parameter (Pn001 = n.
1 ) to bring the servomotor to zero clamp state after stopping.
For details on how to set the parameter, refer to (3) Servomotor Stopping Method When Overtravel is Used .
(1) Signal Setting
Type Name
Connector
Pin Number
Setting Meaning
Input
P-OT
N-OT
CN1-42
CN1-43
ON
OFF
ON
OFF
Forward run allowed.
Normal operation status.
Forward run prohibited. Forward overtravel.
Reverse run allowed. Normal operation status.
Reverse run prohibited. Reverse overtravel.
Rotation in the opposite direction is possible during overtravel by inputting the reference.
4.3 Basic Functions Settings
(2) Overtravel Function Setting
Parameters Pn50A and Pn50B can be set to enable or disable the overtravel function.
If the overtravel function is not used, no wiring for overtravel input signals will be required.
Parameter Meaning
When
Enabled
Pn50A
Pn50B n.2
[Factory setting] n.8
n.
3
[Factory setting] n.
8
Inputs the Forward Run Prohibited (P-OT) signal from
CN1-42.
Disables the Forward Run Prohibited (P-OT) signal.
Allows constant forward rotation.
Inputs the Reverse Run Prohibited (N-OT) signal from
CN1-43.
Disables the Reverse Run Prohibited (N-OT) signal.
Allows constant reverse rotation.
After restart
Classification
Setup
A parameter can be used to re-allocate input connector number for the P-OT and N-OT signals. Refer to 3.4.1
Input Signal Allocations for details.
Note: The factory settings of these parameters in a large-capacity Σ -V SERVOPACK are not all the same as those for a standard Σ -V SERVOPACK.
Make sure that you consider any differences in the factory settings if you copy the parameters from a standard Σ -V
SERVOPACK to a large-capacity Σ -V SERVOPACK.
(3) Servomotor Stopping Method When Overtravel is Used
There are three servomotor stopping methods when an overtravel is used.
• Dynamic brake
By short-circuiting the electric circuits, the servomotor comes to a quick stop.
• Decelerate to a stop
Stops by using emergency stop torque.
• Coast to a stop
Stops naturally, with no control, by using the friction resistance of the servomotor in operation.
After servomotor stopping, there are two modes.
• Coast mode
Stopped naturally, with no control, by using the friction resistance of the servomotor in operation.
• Zero clamp mode
A mode forms a position loop by using the position reference zero.
The servomotor stopping method when an overtravel (P-OT, N-OT) signal is input while the servomotor is operating can be set with parameter Pn001.
Pn001
Parameter n.
00
[Factory setting] n.
01
* n.
02 n.
1 n.
2
Stop Method
DB
Mode After
Stopping
DB
Coast
Coast
Deceleration to a stop
Zero clamp
Coast
When Enabled Classification
After restart Setup
∗ Always connect a dynamic brake circuit for these settings.
• A servomotor under torque control cannot be decelerated to a stop. The servomotor is stopped with the dynamic braking (DB) or coasts to a stop according to the setting of Pn001.0. After the servomotor stops, the servomotor will enter a coast state.
• For details on servomotor stopping methods after the SV_OFF command is received or an alarm occurs, refer to 4.3.5 Stopping Servomotors after SV_OFF Command or Alarm Occurrence .
4
4-7
4-8
4 Operation
4.3.2 Overtravel
When Servomotor Stopping Method is Set to Decelerate to Stop
Emergency stop torque can be set with Pn406.
Pn406
Emergency Stop Torque
Setting Range Setting Unit
Speed Position
Factory Setting
Torque
When Enabled
0 to 800 1% 800 Immediately
Classification
Setup
• The setting unit is a percentage of the rated torque.
• The factory setting is 800% so that the setting is large enough a value to operate the servomotor at maximum torque. The maximum value of emergency stop torque that is actually available, however, is limited to the maximum torque of the servomotor.
(4) Overtravel Warning Function
This function detects an overtravel warning (A.9A0) if overtravel occurs while the servomotor power is ON.
Using this function enables notifying the host controller when the SERVOPACK detects overtravel even if the overtravel signal is ON only momentarily.
To use the overtravel warning function, set digit 4 of Pn00D to 1 (detects overtravel warning).
Warning Output Timing
Command
Motion command ALM_CLR command
Servomotor power OFF ON
MECHA
Overtravel input signal
㧔 P-OT, N-OT signals 㧕
Disabled Enabled
Overtravel warning
㧔 A.9A0
㧕
Disabled
Normal operation
Enabled
Disabled
Warning status
Normal operation
Warning not detected.
<Notes>
• Warnings are detected for overtravel in the same direction as the reference.
• Warnings are not detected for overtravel in the reverse direction from the reference.
Example:A warning will not be output for a forward reference even if the N-OT signal (reverse run prohibited) turns ON.
• A warning can be detected in either the forward or reverse direction, when there is no reference.
• A warning will not be detected when the servomotor power is OFF even if overtravel occurs.
• A warning will not be detected when the servomotor power changes from OFF to ON even if overtravel status exists.
• To clear the overtravel warning, send a Clear Warning or Alarm command (ALM_CLR) regardless of the status of the servomotor power and the overtravel signal. If the warning is cleared by this method during an overtravel state, the occurrence of the warning will not be indicated until the overtravelling is corrected and reset.
• The overtravel warning will be detected when the software limit is in effect.
CAUTION
• The overtravel warning function only detects warnings. It does not affect on stopping for overtravel or motion operations at the host controller. The next step (e.g., the next motion or other command) can be executed even if an overtravel warning exists. However, depending on the processing specifications and programming for warnings in the host controller, operation may be affected when an overtravel warning occurs (e.g., motion may stop or not stop). Confirm the specifications and programming in the host controller.
• When an overtravel occurs, the SERVOPACK will perform stop processing for overtravel. Therefore, when an overtravel warning occurs, the servomotor may not reach the target position specified by the host controller. Check the feedback position to make sure that the axis is stopped at a safe position.
4.3 Basic Functions Settings
Related Parameter
Pn00D
Parameter n.0
[Factory setting] n.1
Meaning
Does not detect overtravel warning.
Detects overtravel warning.
When Enabled Classification
After restart Setup
4
4-9
4-10
4 Operation
4.3.3 Software Limit Settings
4.3.3
Software Limit Settings
The software limits set limits in software for machine movement that do not use the overtravel signals (P-OT and N-OT). If a software limit is exceeded, an emergency stop will be executed in the same way as it is for overtravel.
(1) Software Limit Function
The software limit function can be enabled or disabled.
Use the parameter Pn801.0 to enable the software limit function.
The software limit function can be enabled under the following conditions. Under all other circumstances, the software limits will not be enabled even if a software limit is exceeded.
• The ZRET command has been executed.
• REFE = 1 using the POS_SET command.
Enable or disable the software limits using one of the following settings.
Pn801
Parameter n.
0 n.
n.
1
2 n.
3
[Factory setting]
Description
Software limits enabled in both direction.
Forward software limit enabled.
Reverse software limit enabled.
Both software limits disabled.
When Enabled Classification
Immediately Setup
(2) Software Limit Check using References
Enable or disable software limit checks when target position references such as POSING or INTERPOLATE are input. When the input target position exceeds the software limit, a deceleration stop will be performed from the software limit set position.
When Enabled Classification
Pn801
Parameter n. 0
[Factory setting] n. 1
Description
No software limit check using references.
Software limit check using references.
Immediately Setup
(3) Software Limit Setting
Set software limits value in the positive and negative directions.
Because the limit zone is set according to the forward or reverse direction, the reverse limit must be less than the forward limit.
Pn804
Pn806
Forward Software Limit
Setting Range
-1073741823 to
1073741823
Reverse Software Limit
Setting Unit
1 Reference Unit
Setting Range
-1073741823 to
1073741823
Setting Unit
1 Reference Unit
Factory Setting
819191808
Factory Setting
-819191808
Position
When Enabled
Immediately
Classification
Setup
Position
When Enabled
Immediately
Classification
Setup
4.3 Basic Functions Settings
4.3.4
Holding Brakes
A holding brake is a brake that is used to hold the position of the movable part of the machine when the SER-
VOPACK and converter are turned OFF so that movable part does not move due to gravity or external forces.
Holding brakes are built into servomotors with brakes.
The holding brake is used in the following cases.
Rotation Vertical Shaft
Servomotor
Prevents the movable part from moving due to its own weight when the power is OFF.
Movable part of machine
Holding brake
Shaft with External Force Applied
External force
Movable part of machine
Servomotor
Holding brake
Prevents the movable part (table) from moving due to external force.
• The brake built into the servomotor with brakes is a de-energization brake, which is used only to hold and cannot be used for braking. Use the holding brake only to hold a stopped servomotor.
There is a delay in the braking operation. Set the following ON/OFF timing.
Servo ON command
(SV_ON)
OFF
OFF
Servomotor power
Brake signal (/BK)
OFF
Brake contact part
(lining)
Brake applied
*1
Position reference/
Speed reference
0
ON
ON
ON
Brake release
*1
OFF
*3
OFF
OFF
Brake applied
Motor speed
*2
MECHA
4
4-11
4 Operation
4.3.4 Holding Brakes
4-12
∗1.
The operation delay time of the brake is shown in the following table. The operation delay time is an example when the power supply is turned ON and OFF on the DC side. Be sure to evaluate the above times on the actual equipment before using the application.
Main Circuit Power
Supply Voltage
Three-phase
200 VAC
Three-phase
400 VAC
Servomotor
Model: SGMVV-
2BA B
3ZA B
3GA B
2BA D
3ZA D
3GA D
2BD B
3ZD B
3GD B
4ED B
5ED B
2BD D
3ZD D
3GD D
4ED D
Rated Speed
[min
-1
]
1500
800
1500
800
Voltage
24 VDC or
90 VDC
Brake Open Time
[ms]
500 max.
550 max.
700 max.
500 max.
550 max.
500 max.
550 max.
700 max.
Brake Operation
Time [ms]
150 max.
320 max.
150 max.
320 max.
150 max.
320 max.
An SGMVV-4ED D servomotor is not available in a model with a holding brake.
∗2.
After the SV_ON command has been sent and 50 ms has passed since the brake was released, output the reference from the host controller to the SERVOPACK.
∗3.
Use Pn506, Pn507, and Pn508 to set the timing of when the brake will be activated and when the servomotor power will be turned OFF.
(1) Wiring Example
Use the brake signal (/BK) and the brake power supply to form a brake ON/OFF circuit. The following diagram shows a standard wiring example.
The timing can be easily set using the brake signal (/BK).
SERVOPACK and converter
Servomotor with holding brake
Power supply
400 VAC
L1
L2
L3
U
V
W
M
CN2 ENC
BK
100/200 VAC
24-VDC power supply
+
-
CN101
24 V
0 V
CN1
(/BK+)
BK-RY
+24 V
(/BK-)
1D
0 V
Surge absorber
AC side DC side
Blue or yellow
White
Brake power supply
Red
AC DC
Black
BK-RY
BK-R Y: Brake control relay
Brake power supply for 90 V Input voltage 200-V models: LPSE-2H01-E
Input voltage 100-V models: LPDE-1H01-E
A 24-VDC power supply for a 24-VDC brake is not included.
4.3 Basic Functions Settings
• Select the optimum surge absorber in accordance with the applied brake current and brake power supply.
When using the LPSE-2H01-E power supply: Z10D471 (Made by SEMITEC
Corporation)
When using the LPDE-1H01-E power supply: Z10D271 (Made by SEMITEC
Corporation)
When using the 24-V power supply: Z15D121 (Made by SEMITEC Corporation)
• After the surge absorber is connected, check the total time the brake is applied for the system. Depending on the surge absorber, the total time the brake is applied can be changed.
• Configure the relay circuit to apply the holding brake by the emergency stop.
Relay Circuit Example
SERVOPACK
5 to 24 VDC
Emergency stop
Photocoupler
0 V
• The allocation of the /BK signal can be changed. Refer to (3) Brake Signal (/BK) Allocation to set the parameter Pn50F.
• When using a 24-V brake, separate the 24-VDC power supply from other power supplies, such as the one used for the I/O signals of CN1 connectors. Always install the
24-VDC power supply separately. If the power supply is shared, the I/O signals might malfunction.
(2) Brake Signal (/BK) Setting
This output signal controls the brake. The allocation of the /BK signal can be changed. Refer to (3) Brake Signal (/BK) Allocation for allocation.
The /BK signal turns OFF (applies the brake) when an alarm is detected or the SV_OFF command is received.
The brake OFF timing can be adjusted with Pn506.
Type
Output /BK
Name
Connector
Pin Number
CN1-25, CN1-26
Setting
ON (closed)
OFF (open)
Meaning
Releases the brake.
Applies the brake.
The /BK signal is still ON during overtravel and the brake is still released.
4
4-13
4-14
4 Operation
4.3.4 Holding Brakes
(3) Brake Signal (/BK) Allocation
Use parameter Pn50F.2 to allocate the /BK signal.
Parameter n. 0
Connector
Pin Number
+ Terminal - Terminal
– –
Meaning
The /BK signal is not used.
Pn50F n. 1
[Factory setting] n. 2 n. 3
CN1-25
CN1-27
CN1-29
CN1-26
CN1-28
CN1-30
The /BK signal is output from output terminal CN1-25, 26.
The /BK signal is output from output terminal CN1-27, 28.
The /BK signal is output from output terminal CN1-29, 30.
When
Enabled
Classification
After restart
Setup
When multiple signals are allocated to the same output terminal, the signals are output with OR logic. For the /BK signal, do not use the output terminal that is already being used for another signal.
(4) Brake ON Timing after the Servomotor Stops
When the servomotor stops, the /BK signal turns OFF at the same time as the SV_OFF command is received.
Use parameter Pn506 to change the timing to turn OFF the servomotor power after the SV_OFF command has been received.
Pn506
Brake Reference-Servo OFF Delay Time
Setting Range
0 to 50
Setting Unit
10 ms
Speed
Factory Setting
0
Position Torque
When Enabled
Immediately
Classification
Setup
• When using the servomotor to control a vertical axis, the machine movable part may shift slightly depending on the brake ON timing due to gravity or an external force. To eliminate this slight shift, set parameter so that the power to the servomotor turns
OFF after the brake is applied.
• This parameter changes the brake ON timing while the servomotor is stopped.
SV_OFF command
Servo ON Servo OFF
/BK output
Power to motor
MECHA
Brake released
(ON)
Brake applied
(OFF)
Power to motor No power to motor
Pn506
The servomotor will turn OFF immediately when an alarm occurs, regardless of the setting of this parameter. The machine movable part may shift due to gravity or external force before the brake operates.
4.3 Basic Functions Settings
(5) Brake Signal (/BK) Output Timing during Servomotor Rotation
If an alarm occurs while the servomotor is rotating, the servomotor will come to a stop and the brake signal
(/BK) will be turned OFF. The timing of brake signal (/BK) output can be adjusted by setting the brake reference output speed level (Pn507) and the waiting time for brake signal when motor running (Pn508).
Note: If the servomotor is set so that it comes to a zero-speed stop for an alarm, follow the information in (4) Brake ON
Timing after the Servomotor Stops after the servomotor comes to a stop for a zero position reference.
Pn507
Pn508
Brake Reference Output Speed Level
Setting Range
0 to 10000
Setting Unit
1 min
-1
Speed
Factory Setting
100
Waiting Time for Brake Signal When Motor Running
Setting Range
10 to 100
Setting Unit
10 ms
Speed
Factory Setting
50
Position Torque
When Enabled
Immediately
Classification
Setup
Position Torque Classification
When Enabled
Immediately Setup
/BK Signal Output Conditions
When Servomotor Rotating
The /BK signal goes to high level
(brake ON) when either of the following conditions is satisfied:
• When the motor speed falls below the level set in Pn507 after the power to the servomotor is turned OFF.
• When the time set in Pn508 is exceeded after the power to the servomotor is turned OFF.
SV_OFF command or alarm or power OFF
Motor speed
Power to motor
/BK output
Servo ON
ON
Brake released
(ON)
Servo OFF
Pn-507 Motor stopped by applying
DB or by coasting Pn001.0
OFF
Brake applied
(OFF)
Pn508
MECHA
• The servomotor will be limited to its maximum speed even if the value set in Pn507 is higher than the maximum speed.
• Do not allocate the rotation detection signal (/TGON) and the brake signal (/BK) to the same terminal. The /TGON signal will otherwise be turned ON by the falling speed on a vertical axis, and the brake may not operate.
For the /BK signal, do not use the terminal that is already being used for another signal.
4
4-15
4-16
4 Operation
4.3.5 Stopping Servomotors after SV_OFF Command or Alarm Occurrence
4.3.5
Stopping Servomotors after SV_OFF Command or Alarm Occurrence
The servomotor stopping method can be selected after the SV_OFF command is received or an alarm occurs.
• Dynamic braking (DB) is used for emergency stops. The DB circuit will operate frequently if the power is turned ON and OFF or the SV_ON command and SV_OFF command are received with a reference input applied to start and stop the servomotor, which may result in deterioration of the internal elements in the SERVOPACK and converter.
Use speed input references or position references to start and stop the servomotor.
• If you turn OFF the control power supply during operation without turning OFF the servo, the servomotor will coast to a stop. In this case, you cannot set the stop method in a parameter.
• To minimize the coasting distance of the servomotor to come to a stop when an alarm occurs, the zero-speed stopping method is factory-set for alarms to which the zerospeed stop method is applicable. The DB stopping method may be more suitable than the zero-speed stopping method, however, depending on the application.
For example, for multiple axes coupling operation (a twin-drive operation), machinery damage may result if a zero-speed stop alarm occurs for one of the coupled shafts and the other shaft stops by dynamic brake. In such cases, change the method to the
DB stopping method.
(1) Stopping Method for Servomotor after SV_OFF Command is Received
Use Pn001.0 to select the stopping method for the servomotor after the SV_OFF command is received.
Pn001
Parameter n.
0
*
[Factory setting] n.
n.
1
*
2
DB
Stop Mode
Coast
Mode After Stopping When Enabled Classification
DB
After restart Setup
Coast
Coast
∗ Always connect a dynamic brake circuit for these settings.
Note: Similar to the Coast Mode, the n.
low speed.
0 setting (which stops the servomotor by dynamic braking and then holds it in Dynamic Brake Mode) does not generate any braking force when the servomotor stops or when it rotates at very
(2) Stopping Method for Servomotor When an Alarm Occurs
There are two types of alarms (Gr.1 and Gr.2) that depend on the stopping method when an alarm occurs.
Select the stopping method for the servomotor when an alarm occurs using Pn001.0 and Pn00B.1.
The stopping method for the servomotor for a Gr.1 alarm is set to Pn001.0.
The stopping method for the servomotor for a Gr.2 alarm is set to Pn00B.1.
Refer to the information on alarm stopping methods in 9.1.1 List of Alarms .
4.3 Basic Functions Settings
Stopping Method for Servomotor for Gr.1 Alarms
The stopping method of the servomotor when a Gr.1 alarm occurs is the same as that in (1) Stopping Method for Servomotor after SV_OFF Command is Received .
Pn001
Parameter n.
0
*
[Factory setting] DB n.
1
* n.
2 Coast
Stop Mode
Mode After
Stopping
DB
Coast
Coast
When Enabled
After restart
Classification
Setup
∗ Always connect a dynamic brake circuit for these settings.
Stopping Method for Servomotor for Gr.2 Alarms n.
0
[Factory setting] n.
Pn00B
Parameter
Pn001
1
Stop Mode n.
0
*1
[Factory setting] Zero-speed n.
1
*1 stopping
*2 n.
2 n.
0
*1
[Factory setting] DB n.
1
*1 n.
2 Coast
Mode After
DB
Stopping
Coast
DB
Coast
When Enabled
After restart
Classification
Setup
∗1.
Always connect a dynamic brake circuit for these settings.
∗2.
Zero-speed stopping: The speed reference is set to 0 to stop quickly.
Note: The setting of Pn00B.1 is effective for position control and speed control. Pn00B.1 will be ignored for torque control and only the setting of Pn001.0 will be valid.
4
4-17
4-18
4 Operation
4.3.6 Instantaneous Power Interruption Settings
4.3.6
Instantaneous Power Interruption Settings
Determines whether to continue operation or turn OFF the servomotor’s power when the power supply voltage to the main circuit power supply of the SERVOPACK and converter is interrupted.
Pn509
Instantaneous Power Cut Hold Time
Setting Range
20 to 50000
Setting Unit
1 ms
Speed
Factory Setting
20
Position Torque Classification
When Enabled
Immediately Setup
If the power interruption time is shorter than the set value in Pn509, the servomotor will continue operation. If it is longer than the set value, the servomotor’s power will be turned OFF during the power interruption. The servomotor is turned ON when power supply to the main circuit recovers.
Set value for Pn509
≥
OFF time (t) Set value for Pn509 < OFF time (t)
Instantaneous power interruption Instantaneous power interruption
Main circuit power supply OFF time (t)
Main circuit power supply
OFF time (t)
Set value for
Pn509
Set value for
Pn509
Servomotor status
Power ON
Set value for
Pn509 ≥ OFF time (t)
Operation continues.
Instantaneous power interruption
Servomotor status
Set value for
Pn509 < OFF time (t)
Power OFF
Power ON
Forced OFF
Instantaneous power interruption
Note: If the instantaneous power interruption is longer than the set value of Pn509, the /S-RDY signal turns OFF.
• If the control power supply makes control impossible during an instantaneous power interruption, the same operation will be performed as for normally turning OFF the power supply, and the setting of Pn509 will be ignored.
• The holding time of the main circuit power supply varies with the output of the SER-
VOPACK. If the load on the servomotor is large and an undervoltage alarm (A.410) occurs, the setting of Pn509 will be ignored.
• The holding time of the control power supply (24 VDC) for the 400-V SERVOPACKs depends on the capability of the power supply (not included). Check the power supply before using the application.
If the uninterruptible power supplies are used for the control power supply and main circuit power supply, the
SERVOPACK can withstand an instantaneous power interruption period of 50,000 ms max.
4.3 Basic Functions Settings
4.3.7
SEMI F47 Function (Torque Limit Function for Low DC Power Supply Voltage for Main Circuit)
The torque limit function detects an undervoltage warning and limits the output current if the DC power supply voltage for the main circuit in the SERVOPACK drops to a specified value because the power was momentarily interrupted or the power supply voltage for the main circuit was temporality lowered.
This function complies with SEMI F47 standards for semiconductor production equipment.
Combining this function with the parameter for Instantaneous Power Cut Hold Time allows the servomotor to continue operating without stopping for an alarm or without recovery work even if the power supply voltage drops.
• This function is able to cope with instantaneous power interruptions in the voltage and time ranges stipulated in SEMI F47. An uninterruptible power supply (UPS) is required as a backup for instantaneous power interruptions that exceed these voltage and time ranges.
• This function is intended for voltage drops in the main circuit power supply. The following restrictions apply when it is used to provide an instantaneous power cut hold time in the control power supply.
<Control Power Supply Restrictions>
400-VAC voltage input SERVOPACK: Provide the control power supply from a 24-
VDC power supply that complies with SEMI F47 standards.
• Set the host controller and SERVOPACK torque limit so that a torque reference that exceeds the specified acceleration will not be output when the power supply for the main circuit is restored.
• Do not limit the torque to values lower than the holding torque for the vertical axis.
• This function limits torque within the range of the SERVOPACK's capability when the power is cut. It is not intended for use under all load and operating conditions. Use the actual machine to set parameters while confirming correct operation.
• Setting the Instantaneous Power Cut Hold Time lengthens the amount of time from when the power supply is turned OFF until the motor current turns OFF. Send the
SV_OFF command to instantly stop the motor current.
4
4-19
4-20
4 Operation
4.3.7 SEMI F47 Function (Torque Limit Function for Low DC Power Supply Voltage for Main Circuit)
(1) Execution Method
This function can be executed either with the host controller and the SERVOPACK or with the SERVOPACK only.
With the Host Controller and the SERVOPACK
The host controller limits the torque in response to an undervoltage warning.
The host controller removes the torque limit after the undervoltage warning is cleared.
Main circuit input power supply
Main circuit bus voltage
560 V
400 V
Main circuit power interruption time
Main circuit bus voltage drops slowly because output torque is limited.
Rotation
SERVOPACK
Main circuit bus voltage increases by recovery of the main circuit power.
Undervoltage warning detected
Torque limit starts.
Torque limit
0%
Undervoltage warning
Host controller Torque limit reference
The torque is limited in response to an undervoltage warning.
Torque limit ends.
0%
With the SERVOPACK only
The torque is limited in the SERVOPACK in response to an undervoltage warning.
The SERVOPACK controls the torque limit value in the set time after the undervoltage warning is cleared.
Use Pn008.1 to specify whether the function is executed by the host controller and SERVOPACK or by the
SERVOPACK only.
Main circuit power interruption time
Rotation
Main circuit input power supply
SERVOPACK
Main circuit bus voltage
Undervoltage warning detected
560 V
400 V
Torque limit starts.
Main circuit bus voltage drops slowly because output torque is limited.
Main circuit bus voltage increases by recovery of the main circuit power.
Setting value for Pn425
Torque limit
Setting value for Pn424
0%
4.3 Basic Functions Settings
(2) Related Parameters
Pn008
Parameter n.
0
[Factory setting] n.
1 n.
2
Meaning
Does not detect undervoltage.
Detects warning and limits torque by host controller.
Detects warning and limits torque by Pn424 and Pn425.
(Only in the SERVOPACK)
When Enabled Classification
After restart Setup
Pn424
Pn425
Torque Limit at Main Circuit Voltage Drop
Speed
Setting Range Setting Unit Factory Setting
0 to 100
Release Time for Torque Limit at Main Circuit
Voltage Drop
Setting Range
1%
*
Setting Unit
50
Speed
Factory Setting
0 to 1000 1 ms 100
∗ The setting unit is a percentage of the rated torque.
Pn509
Instantaneous Power Cut Hold Time
Setting Range
20 to 50000
Setting Unit
1 ms
Note: When using SEMI F47 function, set 1000 ms.
Speed
Factory Setting
20
Position Torque
When Enabled
Immediately
Classification
Setup
Position Torque Classification
When Enabled
Immediately Setup
Position Torque Classification
When Enabled
Immediately Setup
4
4-21
4-22
4 Operation
4.3.8 Setting Motor Overload Detection Level
4.3.8
Setting Motor Overload Detection Level
In this SERVOPACK, the detection timing of the warnings and alarms can be changed by changing how to detect an overload warning (A.910) and overload (low load) alarm (A.720).
The overload characteristics and the detection level of the overload (high load) alarm (A.710) cannot be changed.
(1) Changing Detection Timing of Overload Warning (A.910)
The overload warning level is set by default to 20% so that an overload warning is detected in 20% of the time required to detect an overload alarm. The time required to detect an overload warning can be changed by changing the setting of the overload warning level (Pn52B). This protective function enables the warning output signal (/WARN) to serve as a protective function and to be output at the best timing for your system.
The following graph shows an example of the detection of an overload warning when the overload warning level (Pn52B) is changed from 20% to 50%. An overload warning is detected in half of the time required to detect an overload alarm.
Overload detection time
Rotation
Detection curve of overload warning when
Pn52B = 50%
Detection curve of overload alarm
Detection curve of overload warning when Pn52B = 20% (factory setting)
100% 200% Torque reference [%]
Note: For details, refer to Overload Characteristics listed in the section for the relevant servomotor in the Large-Capacity
Σ -V Series Product Catalog (No.: KAEP S800000 86).
Pn52B
Overload Warning Level
Setting Range
1 to 100
Setting Unit
1%
Speed
Factory Setting
20
Position Torque Classification
When Enabled
Immediately Setup
4.3 Basic Functions Settings
(2) Changing Detection Timing of Overload (Low Load) Alarm (A.720)
An overload (low load) alarm (A.720) can be detected earlier to protect the servomotor from overloading. The time required to detect an overload alarm can be shortened by using the derated motor base current obtained with the following equation.
Note: The detection level of the overload (high load) alarm (A.710) cannot be changed.
Motor base current × Derating of base current at detecting overload of motor (Pn52C)
= Derated motor base current
Motor base current: Threshold value of motor current to start calculation for overload alarm
Derating of base current at detecting overload of motor (Pn52C): Derating of motor base current
The following graph shows an example of the detection of an overload alarm when Pn52C is set to 50%. The calculation for the overload of motors starts at 50% of the motor base current and then an overload alarm will be detected earlier.
Changing the setting of Pn52C will change the detection timing of the overload alarm, so the time required to detect the overload warning will also be changed.
Overload detection time
Rotation
Detection curve of overload alarm when
Pn52C = 100% (factory setting)
Detection curve of overload alarm when Pn52C = 50%
50% 100% 200% Torque reference [%]
Note: For details, refer to Overload Characteristics listed in the section for the relevant servomotor in the uct Catalog (No.: KAEP S800000 42).
Σ -V Series Prod-
Pn52C
Derating of Base Current at Detecting Overload of
Motor
Setting Range
10 to 100
Setting Unit
1%
Speed
Factory Setting
100
Position Torque Classification
When Enabled
After restart Setup
4
4-23
4-24
4 Operation
4.4.1 Inspection and Checking before Trial Operation
4.4
Trial Operation
This section describes a trial operation using MECHATROLINK-II communications.
4.4.1
Inspection and Checking before Trial Operation
To ensure safe and correct trial operation, inspect and check the following items before starting trial operation.
(1) Servomotors
Inspect and check the following items, and take appropriate measures before performing trial operation if any problem exists.
• Are all wiring and connections correct?
• Are all nuts and bolts securely tightened?
• If the servomotor has an oil seal, is the seal undamaged and is the servomotor oiled?
Note: When performing trial operation on a servomotor that has been stored for a long period of time, perform the inspection according to the procedures described in 1.10 Inspection and Maintenance .
(2) SERVOPACKs and Converters
Inspect and check the following items, and take appropriate measures before performing trial operation if any problem exists.
• Are all wiring and connections correct?
• Is the correct power supply voltage being supplied to the SERVOPACK and converter?
4.4 Trial Operation
4.4.2
Trial Operation via MECHATROLINK-
II
The following table provides the procedures for trial operation via MECHATROLINK-II.
Step
1
2
3
4
5
6
7
8
9
Description
Confirm that the wiring is correct, and then connect the I/O signal connector (CN1 connector).
Turn ON the power to the SERVOPACK and converter.
If the SERVOPACK and converter are recieving power, the CHARGE indicator on the SERVOPACK and converter will light up.
Also, the POWER and the COM LED indicators on the SERVOPACK will light up.
Note: If the COM LED does not turn ON, recheck the settings of
MECHATROLINK-II setting switches (S2, S3) and then turn the power OFF and ON again.
Send the CONNECT command.
In the response data from the SERVOPACK, the alarm code "00" is cleared to show normal operation.
The response data from the SERVOPACK may be confirmed with the
SMON command.
Check the product type using an ID_RD command.
A reply showing the product type, such as SGDV-750J11A, is received from the SERVOPACK.
Set the following items to the necessary settings for a trial operation.
• Electronic gear settings
• Rotational direction of servomotor
• Overtravel
Reference
3 Wiring and Connection
–
Σ -V Series User’s Manual
MECHATROLINK-II Commands
(No.: SIEP S800000 54)
4.4.3 Electronic Gear
4.3.1 Servomotor Rotation Direction
4.3.2 Overtravel
Save these settings (step 5).
If saving the settings in the controller, use the PRM_WR command.
If saving settings in the SERVOPACK, use the PPRM_WR command.
Send the SV_ON command.
A reply showing that the servomotor has switched to Drive status and that SVON=1 (servomotor power is ON) is received.
Run the servomotor at low speed.
<Example using a positioning command>
Command used: POSING
Command setting: Option = 0, Positioning position =10000 (If using the absolute encoder, add 10000 to the present position), rapid traverse speed= 400
Check the following points while running the servomotor at low speed
(step 8).
• Confirm that the rotational direction of the servomotor correctly coincides with the forward rotation or reverse rotation reference. If they do not coincide, reset the direction.
• Confirm that no unusual vibrations, noises, or temperature rises occur.
If any abnormalities are seen, correct the conditions.
Note: Because the running-in of the load machine is not sufficient at the time of the trial operation, the servomotor may become overloaded.
Σ -V Series User’s Manual
MECHATROLINK-II Commands
(No.: SIEP S800000 54)
–
4.3.1 Servomotor Rotation Direction
9.4 Troubleshooting Malfunction
Based on Operation and Conditions of the Servomotor
4
4-25
4-26
4 Operation
4.4.3 Electronic Gear
4.4.3
Electronic Gear
The electronic gear enables the workpiece travel distance per reference unit input from the host controller. The minimum unit of the position data moving a load is called a reference unit.
The section indicates the difference between using and not using an electronic gear when a workpiece is moved 10 mm in the following configuration.
Workpiece Rotation
Encoder resolution (20 bit) 1048576
Ball screw pitch: 6 mm
When the Electronic Gear is Not Used:
1 Calculate the revolutions.
1 revolution is 6 mm. Therefore, 10 ÷ 6 = 10/6 revolutions.
2 Calculate the required reference units.
1048576 reference units is 1 revolution. Therefore, 10/6 × 1048576 = 1747626.66 reference units.
3 Input 1747627 references as reference units.
Reference units must be calculated per reference. → complicated
When the Electronic Gear is Used:
The reference unit is 1 μ m. Therefore, to move the workpiece 10 mm (10000 μ m),
1 reference unit = 1 μ m, so 10000 1 = 10000 reference units.
Input 10000 reference units.
÷
Calculation of reference units per reference is not required. → simplified
4.4 Trial Operation
(1) Electronic Gear Ratio
Set the electronic gear ratio using Pn20E and Pn210.
Pn20E
Pn210
Electronic Gear Ratio (Numerator)
Setting Range
1 to 1073741824
Setting Unit
1
Electronic Gear Ratio (Denominator)
Setting Range
1 to 1073741824
Setting Unit
1
Factory Setting
4
Factory Setting
1
Position
When Enabled
After restart
Position
When Enabled
After restart
Classification
Setup
Classification
Setup
If the gear ratio of the servomotor and the load shaft is given as n/m where m is the rotation of the servomotor and n is the rotation of the load shaft,
Electronic gear ratio:
B
A
=
Pn20E
Pn210
=
Encoder resolution
Travel distance per load shaft revolution (reference units)
× m n
Encoder Resolution
Encoder resolution can be checked with servomotor model designation.
Rotation
SGMVV
Symbol
3
D
Specification
20-bit absolute
20-bit incremental
Encoder Resolutions
1048576
1048576
Electronic gear ratio setting range: 0.001 ≤ Electronic gear ratio (B/A) ≤ 4000
If the electronic gear ratio is outside this range, a parameter setting error 1 (A.040) will be output.
4
4-27
4-28
4 Operation
4.4.3 Electronic Gear
(2) Electronic Gear Ratio Setting Examples
The following examples show electronic gear ratio settings for different load configurations.
Step Operation
Ball Screw
Reference unit: 0.001 mm
Load shaft
20-bit encoder Ball screw pitch: 6 mm
Load Configuration
Disc Table
Reference unit: 0.01
°
Gear ratio:
1/100
Gear ratio
1/50
Load shaft
20-bit encoder
Belt and Pulley
Reference unit: 0.005 mm
Load shaft
Pulley diameter:
100 mm
20-bit encoder
1
Check machine specifications.
Ball screw pitch: 6 mm
Gear ratio: 1/1
Rotation angle per revolution: 360 °
Gear ratio: 1/100
Pulley diameter: 100 mm
(pulley circumference: 314 mm)
• Gear ratio: 1/50
2
3
4
5
6
Check the encoder resolution.
Determine the reference unit used.
Calculate the travel distance per load shaft revolution. (Reference unit)
1048576 (20-bit)
Reference unit: 0.001 mm
(1 μ m)
6 mm/0.001 mm = 6000
Calculate the electronic gear ratio.
Set parameters.
B
A
=
1048576
6000
Pn20E: 1048576
Pn210: 6000
1
1
1048576 (20-bit)
Reference unit: 0.01
°
360 ° /0.01
° = 36000
B
A
=
1048576
36000
Pn20E: 104857600
Pn210: 36000
100
1
1048576 (20-bit)
Reference unit: 0.005 mm
(5 μ m)
314 mm/0.005 mm =
62800
B
A
=
1048576
62800
Pn20E: 52428800
Pn210: 62800
50
1
4.4 Trial Operation
4.4.4
Encoder Output Pulses
The encoder pulse output is a signal that is output from the encoder and processed inside the SERVOPACK. It is then output externally in the form of two phase pulse signal (phases A and B) with a 90 ° phase differential.
It is used as the position feedback to the host controller.
Signals and output phase form are as shown below.
(1) Signals
Type
Signal
Name
PAO
/PAO
PBO
Output
/PBO
PCO
/PCO
Connector
Pin Number
CN1-33
CN1-34
CN1-35
CN1-36
CN1-19
CN1-20
Name
Encoder output pulse: phase A
Encoder output pulse: phase B
Encoder output pulse: phase C
Remarks
These encoder pulse output pins output the number of pulses per motor revolution that is set in Pn212. Phase
A and phase B are different from each other in phase by an electric angle of 90 ° .
One pulse is output per motor rotation.
Host controller SERVOPACK Rotation
CN1 CN2
PAO
PBO
PCO
Dividing circuit
(Pn212)
Converts serial data to pulse.
Serial data
ENC
(2) Output Phase Form
Forward rotation (phase B leads by 90 ° ) Reverse rotation (phase A leads by 90 ° )
90°
90°
Phase A
Phase B
Phase C t
Phase A
Phase B
Phase C t
Note: The pulse width for phase C (origin pulse) changes according to the setting of the encoder output pulses (Pn212) and becomes the same as that for phase A.
Even in reverse rotation mode (Pn000.0 = 1), the output phase form is the same as that for the standard setting
(Pn000.0 = 0) above.
If using the SERVOPACK’s phase-C pulse output for a zero point return, rotate the servomotor two or more times before starting a zero point return. If the servomotor cannot be rotated two or more times, perform a zero point return at a motor speed of 600 min
-1 or below. If the motor speed is faster than 600 min
-1
, the phase-C pulse may not be output correctly.
4
4-29
4-30
4 Operation
4.4.5 Setting Encoder Output Pulse
4.4.5
Setting Encoder Output Pulse
Set the encoder output pulse using the following parameter.
Pn212
Encoder Output Pulses
Setting Range
16 to 1073741824
Setting Unit
1 P/rev
Speed
Factory Setting
2048
Position Torque
When Enabled
After restart
Classification
Setup
Pulses from the encoder per revolution are divided inside the SERVOPACK by the number set in this parameter before being output. Set the number of encoder output pulses according to the system specifications of the machine or host controller.
Setting Range of Encoder Output
Pulses (P/Rev)
16 to 16384
16386 to 32768
32772 to 65536
65544 to 131072
131088 to 262144
Setting Unit
1
2
4
8
16
Upper Limit of Servomotor Speed for
Set Encoder Output Pulses [min
-1
]
6000
3000
1500
750
375
Note 1. An encoder output pulse setting error (A.041) will occur if the setting does not satisfy the required conditions listed in the table.
Pn212 = 25000 (P/Rev) is accepted, but
Pn212 = 25001 (P/Rev) is not accepted. The alarm A.041 is output because the setting unit differs from that in the above table.
2. The upper limit of the pulse frequency is approximately 1.6 Mpps.
The servomotor speed is limited if the setting value of the encoder output pulses (Pn212) is large.
An overspeed of encoder output pulse rate alarm (A.511) will occur if the motor speed exceeds the upper limit specified in the above table.
Output Example: When Pn212 = 16 (16-pulse output per one revolution), PAO and PBO are output as shown
below.
Preset value: 16
Rotation
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
PAO
PBO
One revolution
4.5 Test Without Motor Function
4.5
Test Without Motor Function
The test without a motor is used to check the operation of the host controller and peripheral devices by simulating the operation of the servomotor in the SERVOPACK, i.e., without actually operating a servomotor. This function enables you to check wiring, verify the system while debugging, and verify parameters, thus shortening the time required for setup work and preventing damage to the machine that may result from possible malfunctions. The operation of the motor can be checked during performing this function regardless of whether the motor is actually connected or not.
Reference
Host controller
SERVOPACK
Reference
Simulates the operation without motor.
M-II
Response Response
Use Pn00C.0 to enable or disable the test without a motor.
Pn00C
Parameter n.
0
[Factory setting] n.
1
Meaning
Disables the test without a motor.
Enables the test without a motor.
When
Enabled
After restart
Classification
Setup
4.5.1
Motor Information
The motor information that is used for a test without a motor is given below.
(1) When Motor is Connected
If a motor is connected, the information from the connected motor is used for the motor and encoder scale information. The set values of Pn00C.1 and Pn00C.2 are not used.
(2) When Motor is Not Connected
The information for the virtual motor that is stored in the SERVOPACK is used. The set values of Pn00C.1 and Pn00C.2 are used for the encoder information.
Encoder Resolution
The encoder information for the motor is set in Pn00C.1. The setting of Pn00C.1 is not used for an external encoder with fully-closed loop control.
Pn00C
Parameter Meaning
When
Enabled
Classification n.
0
[Factory setting] n.
1
Sets the encoder resolution for the test without a motor to 13 bits.
Sets the encoder resolution for the test without a motor to 20 bits.
After restart Setup
4
4-31
4-32
4 Operation
4.5.2 Motor Position and Speed Responses
Encoder Type
The encoder information for the motor is set in Pn00C.2. An external encoder with fully-closed loop control is always regarded as an incremental encoder.
Pn00C
Parameter Meaning
When
Enabled
Classification n.
0
[Factory setting] n.
1
Sets an incremental encoder as an encoder type for the test without a motor.
Sets an absolute encoder as an encoder type for the test without a motor.
After restart Setup
(3) When External Encoder for Fully-closed Loop Control is Connected
The information from an external encoder is used as the encoder information.
(4) When External Encoder for Fully-closed Loop Control is Not Connected
The encoder information stored in the SERVOPACK is used for the encoder information.
• Resolution: 256
• Incremental encoder
4.5.2
Motor Position and Speed Responses
For the test without a motor, the following responses are simulated for references from the host controller according to the gain settings for position or speed control.
• Servomotor position
• Servomotor speed
• Encoder position
The load model, however, will be a rigid system with the moment of inertia ratio that is set in Pn103.
4.5 Test Without Motor Function
4.5.3
Limitations
The following functions cannot be used during the test without a motor.
• Regeneration and dynamic brake operation
• Brake output signal (The brake output signal can be checked with the I/O signal monitor function of the SigmaWin+.)
• Items marked with " × " in the following utility function table.
Fn No.
Contents
Can be used or not
Motor not connected
Motor connected
Fn000 Alarm history display
Fn002 JOG operation
Fn003 Origin search
Fn004 Program JOG operation
Fn005 Initializing parameter settings
Fn006 Clearing alarm history
Fn008 Absolute encoder multiturn reset and encoder alarm reset
Fn00C Offset adjustment of analog monitor output
Fn00D Gain adjustment of analog monitor output
Fn00E Automatic offset-signal adjustment of the motor current detection signal
Fn00F Manual offset-signal adjustment of the motor current detection signal
Fn010 Write prohibited setting
Fn011 Servomotor model display
Fn012 Software version display
Fn013
Multiturn limit value setting change when a multiturn limit disagreement alarm occurs
Fn014 Resetting configuration error in option modules
Fn01B Vibration detection level initialization
Fn01E Display of SERVOPACK and servomotor ID
Fn01F Display of servomotor ID in feedback option module
Fn020 Origin setting
Fn030 Software reset
Fn200 Tuning-less levels setting
Fn201 Advanced autotuning
Fn202 Advanced autotuning by reference
Fn203 One-parameter tuning
Fn204 Anti-resonance control adjustment function
Fn205 Vibration suppression function
Fn206 EasyFFT
Fn207 Online vibration monitor
Note: : Can be used
× : Cannot be used
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
4
4-33
4-34
4 Operation
4.5.4 Digital Operator Displays during Testing without Motor
4.5.4
Digital Operator Displays during Testing without Motor
An asterisk ( ∗ ) is displayed before status display to indicate the test without a motor operation is in progress.
∗ B B − P R M / M O N
U n 0 0 0 = 0 0 0 0 0 0
−
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 8 = 0 0 0 0 0 0 0 0 0 0 0
U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0
(Example: Status of power to the servomotor is OFF)
*RUN
*BB
*PT NT
*P-OT
*N-OT
*HBB
Display Status
Power is supplied to the servomotor.
Power to the servomotor is OFF.
Forward or reverse run is prohibited.
Forward run is prohibited.
Reverse run is prohibited.
In hard-wire base block (safety) state.
Note: The test without a motor status is not displayed during alarm occurs (A.
).
4.6 Limiting Torque
4.6
Limiting Torque
The SERVOPACK provides the following four methods for limiting output torque to protect the machine.
Limiting Method
Internal torque limit
External torque limit
Torque limit with P_TLIM,
N_TLIM commands
*
Description
Always limits torque by setting the parameter.
Limits torque by input signal from the host controller.
Limit torque by using the P_TLIM and N_TLIM commands.
Reference Section
4.6.1
4.6.2
–
Torque limit with P_CL/
N_CL signals of OPTION
Field and P_TLIM/N_TLIM commands
*
Combines torque limit methods by using an external input and
P_TLIM and N_TLIM commands.
∗ For details, refer to Σ -V Series User’s Manual MECHATROLINK-II Commands (No.: SIEP S800000 54).
Note: The maximum torque of the servomotor is used when the set value exceeds the maximum torque.
–
4.6.1
Internal Torque Limit
This function always limits maximum output torque by setting values of following parameters.
Pn402
Pn403
Forward Torque Limit
Setting Range
0 to 800
Reverse Torque Limit
Setting Range
0 to 800
Setting Unit
1%
Speed
Factory Setting
800
Speed
Factory Setting
800
Position Torque
When Enabled
Immediately
Position Torque
When Enabled
Immediately
Classification
Setup
Classification
Setup
Maximum torque
Speed
Setting Unit
1%
The setting unit is a percentage of the rated torque.
Note: If the settings of Pn402 and Pn403 are too low, the torque may be insufficient for acceleration or deceleration of the servomotor.
Torque waveform
No Internal Torque Limit
(Maximum torque can be output)
Internal Torque Limit
Rotation
Limiting torque
Speed
Pn402 t t
Pn403
4
4-35
4-36
4 Operation
4.6.2 External Torque Limit
4.6.2
External Torque Limit
Use this function to limit torque by inputting a signal from the host controller at specific times during machine operation. For example, some pressure must continually be applied (but not enough to damage the workpiece) when the robot is holding a workpiece or when a device is stopping on contact.
(1) Input Signals
Use the following input signals to limit a torque by external torque limit.
Type
Input
Input
Signal
Name
/P-CL
/N-CL
Connector
Pin Number
Setting
Must be allocated
Must be allocated
ON
(closed)
OFF
(open)
ON
(closed)
OFF
(open)
Meaning
Pn403
Limit value
Forward external torque limit ON
The smaller value of these settings: Pn402 or Pn404
Forward external torque limit
OFF
Pn402
Reverse external torque limit
OFF
Note: Use parameter Pn50B.2 and Pn50B.3 to allocate the /P-CL signal and the /N-CL signal for use. For details, refer to
3.4.1 Input Signal Allocations .
(2) Related Parameters
Set the following parameters for external torque limit.
Pn402
Pn403
Pn404
Pn405
Forward Torque Limit
Setting Range
0 to 800
Reverse Torque Limit
Setting Range
0 to 800
Setting Unit
1%
Setting Unit
1%
Forward External Torque Limit
Setting Range
0 to 800
Setting Unit
1%
Reverse External Torque Limit
Setting Range
0 to 800
Setting Unit
1%
Speed
Factory Setting
800
Speed
Factory Setting
800
Speed
Factory Setting
100
Speed
Factory Setting
100
Position Torque
When Enabled
Immediately
Position Torque
When Enabled
Immediately
Position Torque
When Enabled
Immediately
Position Torque
When Enabled
Immediately
Classification
Setup
Classification
Setup
Classification
Setup
Classification
Setup
The setting unit is a percentage of the rated torque.
Note: If the settings of Pn402, Pn403, Pn404, and Pn405 are too low, the torque may be insufficient for acceleration or deceleration of the servomotor.
4.6 Limiting Torque
(3) Changes in Output Torque during External Torque Limiting
The following diagrams show the change in output torque when the internal torque limit is set to 800%.
In this example, the servomotor rotation direction is Pn000.0 = 0 (Sets CCW as forward direction).
/P-CL
OFF ON
OFF
Pn402
Speed
Pn402
Pn404
0
Speed
0
Torque Torque
/N-CL
Pn403
Pn402
Speed
Pn403
Pn402
Pn404
Speed
ON
0
Pn405
0
Pn405
Torque Torque
Pn403 Pn403
4.6.3
Checking Output Torque Limiting during Operation
The following signal can be output to indicate that the servomotor output torque is being limited.
Type Signal Name
Connector
Pin Number
Setting Meaning
Output /CLT Must be allocated
ON (closed)
OFF (open)
Servomotor output torque is being limited.
Servomotor output torque is not being limited.
Note: Use parameter Pn50F.0 to allocate the /CLT signal for use. For details, refer to 3.4.2 Output Signal Allocations .
4
4-37
4-38
4 Operation
4.7
Absolute Encoders
If using an absolute encoder, a system to detect the absolute position can be designed for use with the host controller. As a result, an operation can be performed without a zero point return operation immediately after the power is turned ON.
A battery case is required to save position data in the absolute encoder.
The battery is attached to the battery case of the encoder cable.
If an encoder cable with a battery case is not used, install a battery to the host controller.
PROHIBITED
• Do not install batteries in both the host controller and battery case. It is dangerous because that sets up a loop circuit between the batteries.
Set Pn002.2 to 0 (factory setting) to use the absolute encoder.
Pn002
Parameter Meaning n. 0
[Factory setting] Uses the absolute encoder as an absolute encoder.
n. 1 Uses the absolute encoder as an incremental encoder.
When
Enabled
After restart
A battery is not required when using the absolute encoder as an incremental encoder.
Classification
Setup
The output range of the rotational serial data for the absolute position detecting system used for Σ V large-capacity servo drives is different from that of SGDB Σ servo drives. As a result, the infinite-length positioning system of the Σ servo drives must be changed for use with Σ V large-capacity servo drives. Be sure to make the following system modifications.
Σ
SERVOPACK
Series
SGDB
Σ II ,
Σ V (large-capacity)
Series
SGDM
SGDH
SGDV
Absolute
Encoder
Resolution
Output Range of Rotational
Serial Data
12-bit
15-bit
17-bit
20-bit
-99999 to
+ 99999
-32768 to
+ 32767
Action when Limit Is Exceeded
• When the upper limit (+99999) is exceeded in the forward direction, the rotational serial data will be 0.
• When the lower limit (-99999) is exceeded in the reverse direction, the rotational serial data will be 0.
• When the upper limit (+32767) is exceeded in the forward direction, the rotational serial data will be -32768.
*
• When the lower limit (-32768) is exceeded in the reverse direction, the rotational serial data will be +32767.
*
∗ The action differs when the multiturn limit setting (Pn205) is changed. Refer to 4.7.6 Multiturn
Limit Setting .
4.7 Absolute Encoders
4.7.1
Connecting the Absolute Encoder
The following diagram shows the connection between a servomotor with an absolute encoder, the SERVO-
PACK, and the host controller.
(1) Using an Encoder Cable with a Battery Case
Host controller MECHA
Absolute encoder
∗
1
ENC
∗
2
PS
/PS
SERVOPACK
Phase A
CN1
33
34
Phase B 35
36
CN2
5
6
Phase C 19
20
Output line-driver
SN75ALS174 manufactured by Texas
Instruments or the equivalent
16 SG
PAO
/PAO
PBO
/PBO
PCO
/PCO
∗
2
R
R
R
Phase A
Phase B
Phase C
0 V
FG
BAT(+)
BAT(-)
3
4
∗
3
Battery
PG5 V
PG0 V
1
2
Connector shell
Encoder cable with battery case
Connector shell
Applicable line receiver: SN75ALS175 or MC3486 manufactured by Texas
Instruments or the equivalent
Terminating resistance R: 220 to 470
Ω
∗1.
The absolute encoder pin numbers for the connector wiring depend on the servomotors.
∗2.
: represents shielded twisted-pair wires.
∗3.
When using an absolute encoder, provide power by installing an encoder cable with a JUSP-BA01-E Battery Case or install a battery on the host controller.
4
4-39
4-40
4 Operation
4.7.1 Connecting the Absolute Encoder
(2) Installing the Battery in the Host Controller
Absolute encoder
∗
1
ENC
∗
2
PS
/PS
SERVOPACK
Phase A
Phase B
CN2
5
6
Phase C
Output line-driver
SN75ALS174 manufactured by Texas
Instruments or the equivalent
1
CN1
33
34
35
36
19
20
PAO
/PAO
PBO
/PBO
PCO
/PCO
SG
∗
2
R
R
R
Host controller
Phase A
Phase B
Phase C
MECHA
BAT(+)
BAT(-)
PG5 V
PG0 V
3
4
1
2
CN1
21
22
BAT (+)
BAT (-)
+
-
Battery
∗
3
FG
Connector shell
Connector shell
Applicable line receiver: SN75ALS175 or
MC3486 manufactured by Texas
Instruments or the equivalent
Terminating resistance R: 220 to 470
Ω
∗1.
The absolute encoder pin numbers for the connector wiring depend on the servomotors.
∗2.
: represents shielded twisted-pair wires.
0 V
∗3.
When using an absolute encoder, provide power by installing an encoder cable with a JUSP-BA01-E Battery Case or install a battery on the host controller.
4.7 Absolute Encoders
4.7.2
Absolute Data Request (SENS ON Command)
The Turn Encoder Power Supply ON command (SENS_ON) must be sent to obtain absolute data as an output from the SERVOPACK.
The SENS_ON command is sent at the following timing.
SERVOPACK control power supply
OFF
ON
5 seconds max.
ON (Normal status)
ALM signal OFF
(Alarm status)
SENS_ON
(Turn Encoder Power
Supply ON)
OFF
ON
OFF
PAO
PBO
Undefined
Undefined
Rotational serial data
Initial incremental pulses
(Phase A)
Incremental pulses
(Phase A)
Initial incremental pulses
Incremental pulses
(Phase B) (Phase B)
ON
Servomotor power
50 ms
60 ms max.
(90 ms typ.)
Approx.
15 ms
400 ms max.
1 to 3 ms
The servomotor will not be turned ON even if the
SV_ON command is received during this interval.
∗ Send the SENS_OFF command to turn OFF the control power supply.
*
OFF
OFF
OFF
OFF
M-II
4
4-41
4-42
4 Operation
4.7.3 Battery Replacement
4.7.3
Battery Replacement
If the battery voltage drops to approximately 2.7 V or less, an absolute encoder battery error alarm (A.830) or an absolute encoder battery error warning (A.930) will be displayed.
If this alarm or warning is displayed, replace the batteries using the following procedure.
Use Pn008.0 to set either an alarm (A.830) or a warning (A.930).
When
Enabled
Classification
Pn008
Parameter Meaning n.
0
[Factory setting] n.
1
Outputs the alarm A.830 when the battery voltage drops.
Outputs the warning A.930 when the battery voltage drops.
After restart Setup
• If Pn008.0 is set to 0, alarm detection will be enabled for 4 seconds after the ALM signal outputs max. 5 seconds when the control power is turned ON.
No battery-related alarm will be displayed even if the battery voltage drops below the specified value after these 4 seconds.
• If Pn008.0 is set to 1, alarm detection will be always enabled after the ALM signal outputs max. 5 seconds when the control power supply is turned ON.
ON Rotation
Control power
ALM
OFF
Alarm status
5 s max.
Normal status
4 s
Alarm A.830
(Pn008.0 = 0)
Battery voltage being monitored
Warning A.930
(Pn008.0 = 1)
Battery voltage being monitored
(1) Battery Replacement Procedure
Using an Encoder Cable with a Battery Case
1. Turn ON the control power supply to only the SERVOPACK and converter.
2. Open the battery case cover.
Open the cover.
Rotation
4.7 Absolute Encoders
3. Remove the old battery and mount the new JZSP-BA01 battery as shown below.
To the SERVOPACK
Rotation
Encoder Cable
Mount the JZSP-BA01 battery.
4. Close the battery case cover.
Close the cover.
Rotation
5. After replacing the battery, turn OFF the control power supply to clear the absolute encoder battery error alarm (A.830).
6. Turn ON the control power supply again.
7. Check that the alarm display has been cleared and that the SERVOPACK and converter operate normally.
If the control power supply to the SERVOPACK and converter is turned OFF and the battery is disconnected (which includes disconnecting the encoder cable), the absolute encoder data will be deleted.
4
4-43
4-44
4 Operation
4.7.4 Absolute Encoder Setup and Reinitialization
Installing a Battery in the Host Controller
1. Turn ON the control power supply to only the SERVOPACK and converter.
2. Remove the old battery and mount the new battery.
3. After replacing the battery, turn OFF the control power supply to clear the absolute encoder battery error alarm (A.830).
4. Turn ON the control power supply again.
5. Check that the alarm display has been cleared and that the SERVOPACK and converter operate normally.
4.7.4
Absolute Encoder Setup and Reinitialization
CAUTION
• The rotational data will be a value between -2 and +2 rotations when the absolute encoder setup is executed. The reference position of the machine system will change. Set the reference position of the host controller to the position after setup.
If the machine is started without adjusting the position of the host controller, unexpected operation may cause injury or damage to the machine. Take sufficient care when operating the machine.
Setting up and reinitialization of the absolute encoder are necessary in the following cases.
• When starting the machine for the first time
• When an encoder backup error alarm (A.810) is generated
• When an encoder checksum error alarm (A.820) is generated
• When initializing the rotational serial data of the absolute encoder
Set up the absolute encoder with Fn008.
(1) Precautions on Setup and Reinitialization
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
• Set up or reinitialize the encoder when the servomotor power is OFF.
• If the following absolute encoder alarms are displayed, cancel the alarm by using the same method as the set up (initializing) with Fn008. They cannot be canceled with the SERVOPACK Clear Warning or Alarm command (ALM_CLR).
• Encoder backup error alarm (A.810)
• Encoder checksum error alarm (A.820)
• Any other alarms (A.8
power.
) that monitor the inside of the encoder should be canceled by turning OFF the
(2) Procedure for Setup and Reinitialization
Follow the steps below to setup or reinitialize the absolute encoder.This setting can be performed using the adjustment command (ADJ). For details, refer to
(No.: SIEP S800000 54).
Σ -V Series User’s Manual MECHATROLINK-II Commands
Step
1
Panel Display
B B
F U N C T I O N -
F n 0 0 6 : A l m H i s t C l r
F n 0 0 8 : M t u r n C l r
F n 0 0 9 : R e f A d j
F n 0 0 A : V e l A d j
2
B B
M u l t i t u r n C l e a r
P G C L 1
Keys Description
Press the press the
Key to select the utility function. And
or Key to select the Fn008.
Press the Key to view the execution display of
Fn008.
4.7 Absolute Encoders
(cont’d)
Step
3
Panel Display
B B
M u l t i t u r n C l e a r
P G C L 5
Keys
Keep pressing the
Description changed to "PGCL5."
Key until "PGCL1" is
4
B B
M u l t i t u r n C l e a r
P G C L 5
Press the Key to setup the absolute encoder.
After completing the setup, "DONE" is flashed for approximately one second and "BB" is displayed.
5
B B
-
F U N C T I O N
-
F n 0 0 6 : A l m H i s t C l r
F n 0 0 8 : M t u r n C l r
F n 0 0 9 : R e f A d j
F n 0 0 A : V e l A d j
Press the cedure 1.
6 To enable the change in the setting, turn the power OFF and ON again.
Key to return to the display of the pro-
4
4-45
4-46
4 Operation
4.7.5 Absolute Data Reception Sequence
4.7.5
Absolute Data Reception Sequence
The sequence in which the SERVOPACK receives outputs from the absolute encoder and transmits them to host controller is shown below.
(1) Outline of Absolute Data
The serial data, pulses, etc., of the absolute encoder that are output from the SERVOPACK are output from the
PAO, PBO, and PCO signals as shown below.
Host controller SERVOPACK
MECHA
CN1 CN2
PAO
PBO
PCO
Dividing circuit
(Pn212)
Serial data→ pulse conversion
Serial data
ENC
Signal Name
PAO
PBO
PCO
Status
At initialization
Contents
Rotational serial data
Initial incremental pulses
Normal Operations Incremental pulses
At initialization Initial incremental pulses
Normal Operations Incremental pulses
Always Origin pulses
Phase-C Output Specifications
The pulse width of phase C (origin pulse) changes depending on the encoder output pulse (Pn212), becoming the same width as phase A.
The output timing is one of the following.
• Synchronized with the rising edge of phase A
• Synchronized with the falling edge of phase A
• Synchronized with the rising edge of phase B
• Synchronized with the falling edge of phase B
Note: When host controller receives the data of absolute encoder, do not perform counter reset using the output of PCO signal.
(2) Absolute Data Reception Sequence
1. Send the Turn Encoder Power Supply ON (SENS_ON) command from the host controller.
2. After 100 ms, the system is set to rotational serial data reception standby and the incremental pulse up/ down counter is cleared to zero.
3. Eight characters of rotational serial data is received.
4. The system enters a normal incremental operation state about 400 ms after the last rotational serial data is received.
SENS_ON
(Turn Encoder
Power Supply ON)
Rotational serial data
M-II
PAO
PBO
Undefined
Undefined
Initial incremental pulses
(Phase A) (Phase A)
Incremental pulses
Initial incremental pulses
Incremental pulses
(Phase B) (Phase B)
50 ms
60 ms min.
90 ms typ.
Approx. 15 ms
400 ms max.
1 to 3 ms
4.7 Absolute Encoders
Note: The output pulses are phase-B advanced if the servomotor is turning forward regardless of the setting in Pn000.0.
Rotational serial data:
Indicates how many turns the motor shaft has made from the reference position, which was the position at setup.
Initial incremental pulses:
Initial incremental pulses which provide absolute data are the number of pulses required to rotate the motor shaft from the servomotor origin to the present position.
Just as with normal incremental pulses, these pulses are divided by the dividing circuit inside the SERVO-
PACK and then output.
The initial incremental pulse speed depends on the setting of the encoder output pulses (Pn212). Use the following formula to obtain the initial incremental pulse speed.
Setting of the Encoder Output Pulses
(Pn212)
16 to 16384
16386 to 32768
32772 to 65536
65544 to 131072
131088 to 262144
Formula of the Initial Incremental Pulse Speed
680 × Pn212
16384
[kpps]
680 × Pn212
32768
[kpps]
680 × Pn212
65536
[kpps]
680 × Pn212
131072
[kpps]
680 × Pn212
262144
[kpps]
Coordinate value
Value of M
- 1
-1
0
Reference position
(at setup)
+1
±
0
M
×
R
+1
P
E
P
S
P
M
Final absolute data P
M is calculated by following formula.
Current position
+2
+2
P
O
+3
Rotation
P
E
= M × R + P
O
P
S
= M
S
× R + P
S
’
P
M
= P
E
- P
S
Signal
M
S
P
S
’
P
M
R
P
E
M
P
O
P
S
Current value read by encoder
Rotational serial data
Number of initial incremental pulses
Meaning
Absolute data read at setup (This is saved and controlled by the host controller.)
Rotational serial data read at setup
Number of initial incremental pulses read at setup
Current value required for the user’s system
Number of pulses per encoder revolution (pulse count after dividing, value of Pn212)
Note: The following formula applies in reverse mode. (Pn000.0 = 1)
P
P
E
S
= –M × R + P
= M
S
P
M
= P
E
× R + P
S
– P
S
O
'
4
4-47
4-48
4 Operation
4.7.5 Absolute Data Reception Sequence
(3) Rotational Serial Data Specifications and Initial Incremental Pulses
Rotational Serial Data Specifications
The rotational serial data is output from PAO signal.
Data Transfer
Method
Baud rate
Start bits
Stop bits
Parity
Character code
Data format
Start-stop Synchronization (ASYNC)
9600 bps
1 bit
1 bit
Even
ASCII 7-bit code
8 characters, as shown below.
"P"
"+" or " - "
"0" to "9"
Rotational data in five digits
"CR"
Rotation
0 0 0 0 0 1 0 1 0 1
Data Stop bit
Start bit Even parity
Note 1. Data is "P+00000" (CR) or "P-00000" (CR) when the number of revolutions is zero.
2. The revolution range is "-32768" to "+32767". When this range is exceeded, the data changes from "+32767" to "-32678" or from "-32678" to "+32767". When changing multiturn limit, the range changes. For details, refer to 4.7.6 Multiturn Limit Setting .
Initial Incremental Pulses
The initial incremental pulses are output after division inside the SERVOPACK in the same way as for normal incremental pulses. Refer to 4.4.4 Encoder Output Pulses for details.
4.7 Absolute Encoders
(4) Transferring Alarm Contents
If an absolute encoder is used, the contents of alarms detected by the SERVOPACK are transmitted in serial data to the host controller from the PAO output when the Turn Encoder Power Supply OFF command
(SENS_OFF) is received.
Note: The SENS_OFF command cannot be received while the servomotor power is ON.
Output example of alarm contents are as shown below.
Turn Encoder
Power Supply
OFF
(SENS_OFF)
Error detection
Encoder power supply ON
Encoder power supply OFF
M-II
Panel Display or
Overspeed
PAO Output
Incremental pulse
Enlarged view
Serial Data
Serial Data Format
A L M 5 1 .
CR "
Upper 2 digits
4
4-49
4-50
4 Operation
4.7.6 Multiturn Limit Setting
4.7.6
Multiturn Limit Setting
The multiturn limit setting is used in position control applications for a turntable or other rotating device. For example, consider a machine that moves the turntable in the following diagram in only one direction.
Turntable
Rotation
Gear
Servomotor
Because the turntable moves in only one direction, the upper limit for revolutions that can be counted by an absolute encoder will eventually be exceeded. The multiturn limit setting is used in cases like this to prevent fractions from being produced by the integral ratio of the motor revolutions and turntable revolutions.
For a machine with a gear ratio of n:m, as shown above, the value of m minus 1 will be the setting for the multiturn limit setting (Pn205).
Multiturn limit setting (Pn205) = m-1
The case in which the relationship between the turntable revolutions and motor revolutions is m = 100 and n =
3 is shown in the following graph.
Pn205 is set to 99.
Pn205 = 100 − 1 = 99
Table rotations
4
3
2
1
0
9
8
7
6
5
Rotation
Rotational data
Table rotations
Set value of Pn205 = 99
100 200 300 0
Motor rotations
Rotational serial data
100
50
Pn205
Multiturn Limit Setting
Setting Range
0 to 65535
Setting Unit
1 Rev
Speed
Factory Setting
65535
Position Torque
When Enabled
After restart
Classification
Setup
Note: This parameter is valid when the absolute encoder is used.
The range of the data will vary when this parameter is set to anything other than the factory setting.
1. When the motor rotates in the reverse direction with the rotational data at 0, the rotational data will change to the setting of Pn205.
2. When the motor rotates in the forward direction with the rotational data at the Pn205 setting, the rotational data will change to 0.
4.7 Absolute Encoders
Set the value, the desired rotational amount -1, to Pn205.
Factory Setting (= 65535)
+32767
Forward Reverse
Rotational
0 data
Other Setting ( ≠ 65535)
Pn205 setting value
Rotational data
0
Forward Reverse
Motor rotations
-32768 Motor rotations
4.7.7
Multiturn Limit Disagreement Alarm (A.CC0)
When the multiturn limit set value is changed with parameter Pn205, a multiturn limit disagreement alarm
(A.CC0) will be displayed because the value differs from that of the encoder.
Alarm
Display
Alarm Name Alarm Output Meaning
A.CC0
Multiturn Limit Disagreement OFF (H)
Different multiturn limits have been set in the encoder and SERVOPACK.
If this alarm is displayed, perform the operation described below and change the multiturn limit value in the encoder to the value set in Pn205.
This setting can be performed with the adjustment command (ADJ).
For information the adjustment command (ADJ), refer to
Commands (No.: SIEP S800000 54).
Σ -V Series User’s Manual MECHATROLINK-II
Step
1
Display after Operation
A . C C 0
F U N C T I O N -
F n 0 1 2 : S o f t V e r
F n 0 1 3 : M t u r n L m S e t
F n 0 1 4 : O p t I n i t
F n 0 1 B : V i b l v l I n i t
Keys
Press the press the
Operation
Key to select the utility function. And
or Key to select the Fn013.
2
3
A . C C 0
ޓ M u l t i t u r n L i m i t
ޓ ޓ ޓ S e t
ޓ ޓ S t a r t : [ D A T A ]
ޓ ޓ R e t u r n : [ S E T ]
A . C C 0
M u l t i t u r n L i m i t
S e t
S t a r t : [ D A T A ]
R e t u r n : [ S E T ]
Press the Key to view the execution display of
Fn013.
Note: If the display is not switched and “NO-OP” is displayed in the status display, the Write Prohibited Setting (Fn010 = 0001) is set. Check the setting and reset.
Press the Key to set the multiturn limit value.
When the setting is completed, the status display shows "DONE" for one second. The status display then returns to show "A.CC0" again.
Note: If the Key is pressed instead of the
Key, the multiturn limit value will not be reset.
4
A . C C 0
F U N C T I O N -
F n 0 1 2 : S o f t V e r
F n 0 1 3 : M t u r n L m S e t
F n 0 1 4 : O p t I n i t
F n 0 1 B : V i b l v l I n i t
Press the dure 1.
5 To enable the change in the setting, turn the power OFF and ON again.
Key to return to the display the proce-
4
4-51
4-52
4 Operation
4.7.8 Absolute Encoder Origin Offset
4.7.8
Absolute Encoder Origin Offset
If using the absolute encoder, the positions of the encoder and the offset of the machine coordinate system
(APOS) can be set. Use Pn808 to make the setting. After the SENS_ON command is received by MECHA-
TROLINK communications, this parameter will be enabled.
Pn808
Absolute Encoder Origin Offset
Setting Range
-1073741823 to
1073741823
Setting Unit
1 reference unit
Factory Setting
Position
When Enabled
0 Immediately
<Example>
If the encoder position (X) is set at the origin of the machine coordinate system (0), Pn808 = X.
Classification
Setup
Origin
MECHA
Machine coordinate system position
(APOS)
Encoder position
Encoder position: Origin
Pn808 Encoder position
4.8 Other Output Signals
4.8
Other Output Signals
This section explains other output signals.
Use these signals according to the application needs, e.g., for machine protection.
4.8.1
Servo Alarm Output Signal (ALM)
This section describes signals that are output when the SERVOPACK detects errors and resetting methods.
(1) Servo Alarm Output Signal (ALM)
This signal is output when the SERVOPACK detects an error.
Configure an external circuit so that this alarm output turns OFF the main circuit power supply to the SERVOPACK and converter whenever an error occurs.
Type
Signal
Name
Connector
Pin Number
Setting Meaning
Output ALM CN1-31, 32
ON (closed)
OFF (open)
Normal status
Alarm status
(2) Alarm Reset Method
If a servo alarm (ALM) occurs, use one of the following methods to reset the alarm after eliminating the cause of the alarm.
Be sure to eliminate the cause of the alarm before resetting it.
If the alarm is reset and operation continued without eliminating the cause of the alarm, it may result in damage to the equipment or fire.
Resetting Alarms by Sending Clear Warning or Alarm Command (ALM_CLR)
For details, refer to Σ -V Series User’s Manual, MECHATROLINK-II Commands (No.: SIEP S800000 54).
Resetting Alarms Using the Digital Operator
Press the ALARM RESET Key on the digital operator. For details, refer to tion of Digital Operator (No.: SIEP S800000 55).
Σ -V Series User’s Manual, Opera-
4.8.2
Warning Output Signal (/WARN)
This signal is for a warning issued before the occurrence of an alarm.
Refer to 9.2.1 List of Warnings .
(1) Signal Specifications
Type
Signal
Name
Connector Pin
Number
Setting Meaning
Output /WARN Must be allocated
ON (closed)
OFF (open)
Warning status
Normal status
Note: Use parameter Pn50F.3 to allocate the /WARN signal for use. For details, refer to 3.4.2 Output Signal Allocations .
4
4-53
4-54
4 Operation
4.8.3 Rotation Detection Output Signal (/TGON)
4.8.3
Rotation Detection Output Signal (/TGON)
This output signal indicates that the servomotor is rotating at the speed set for Pn502 or a higher speed.
(1) Signal Specifications
Type
Signal
Name
Connector Pin
Number
Setting Meaning
Output /TGON Must be allocated
ON (closed)
OFF (open)
Servomotor is rotating with the motor speed above the setting in Pn502.
Servomotor is rotating with the motor speed below the setting in Pn502.
Note: Use parameter Pn50E.2 to allocate the /TGON signal for use. For details, refer to 3.4.2 Output Signal Allocations .
(2) Related Parameter
Set the range in which the /TGON signal is output using the following parameter.
Pn502
Rotation Detection Level
Setting Range
1 to 10000
Setting Unit
1 min
-1
Speed
Factory Setting
Position Torque
When Enabled
20 Immediately
Classification
Setup
4.8.4
Servo Ready Output Signal (/S-RDY)
This signal is turned ON when the SERVOPACK is ready to accept the servo ON (SV_ON) command.
The /S-RDY signal is turned ON under the following conditions.
• The main circuit power supply is ON.
• No hard wire base block state
• No servo alarms
• The Turn Encoder Power Supply ON (SENS_ON) command is received. (When an absolute encoder is used.)
If an absolute encoder is used, the output of absolute data to the host controller must have been completed when the SENS_ON command is received.
For details on the hard wire base block function, refer to 4.9.1 Hard Wire Base Block (HWBB) Function .
(1) Signal Specifications
Type
Signal
Name
Connector Pin
Number
Setting Meaning
Output /S-RDY Must be allocated
ON (closed)
OFF (open)
The SERVOPACK is ready to accept the SV_ON command.
The SERVOPACK is not ready to accept the
SV_ON command.
Note 1. Use parameter Pn50E.3 to allocate the /S-RDY signal for use. For details, refer to 3.4.2 Output Signal Allocations .
2. For details on the hard wire base block function and the servo ready output signal, refer to 4.9.1 Hard Wire Base
Block (HWBB) Function .
4.8 Other Output Signals
4.8.5
Speed Coincidence Output Signal (/V-CMP)
The speed coincidence output signal (/V-CMP) is output when the actual servomotor speed is the same as the reference speed. The host controller uses the signal as an interlock. This signal is the output signal during speed control.
Type
Signal
Name
Connector Pin
Number
Setting Meaning
Output /V-CMP Must be allocated
ON (closed)
OFF (open)
Speed coincides.
Speed does not coincide.
Note: Use parameter Pn50E.1 to allocate the /V-CMP signal for use. Refer to 3.4.2 Output Signal Allocations for details.
Pn503
Speed Coincidence Signal Output Width
Setting Range
0 to 100
Setting Unit
1 min
-1
Speed
Factory Setting
10
When Enabled
Immediately
Classification
Setup
The /V-CMP signal is output when the difference between the reference speed and actual motor speed is below this setting.
Motor speed
Rotation
Pn503
Reference speed
/V-CMP is output in this range.
<Example>
The /V-CMP signal is output at 1900 to 2100 min min -1 .
-1
if the Pn503 is set to 100 and the reference speed is 2000
4
4-55
4-56
4 Operation
4.8.6 Positioning Completed Output Signal (/COIN)
4.8.6
Positioning Completed Output Signal (/COIN)
This signal indicates that servomotor movement has been completed during position control.
When the difference between the number of references output by the host controller and the travel distance of the servomotor (position error) drops below the set value in the parameter, the positioning completion signal will be output.
Use this signal to check the completion of positioning from the host controller.
Type
Signal
Name
Output /COIN
Connector
Pin Number
Must be allocated
Setting
ON (closed)
OFF (open)
Meaning
Positioning has been completed.
Positioning is not completed.
Note: Use parameter Pn50E.0 to allocate the /COIN signal for use. Refer to 3.4.2 Output Signal Allocations for details.
Pn522
Positioning Completed Width
Setting Range
0 to 1073741824
Setting Unit
1 reference unit
Factory Setting
7
Position
When Enabled
Immediately
The positioning completed width setting has no effect on final positioning accuracy.
Reference
Motor speed
Motor speed
Classification
Setup
Position error
/COIN
Pn522
Time
Time
Time
Effective at ON (close).
Note: If the parameter is set to a value that is too large, a positioning completed signal might be output if the position error is low during a low speed operation. This will cause the positioning completed signal to be output continuously. If this signal is output unexpectedly, reduce the set value until it is no longer output.
If the position error is kept to a minimum when the positioning completed width is small, use Pn207.3 to change output timing for the /COIN signal.
Pn207
Parameter Name Meaning n.0
[Factory setting] n.1
n.2
/COIN Output
Timing
When the absolute value of the position error is below the positioning completed width (Pn522).
When the absolute value of the position error is below the positioning completed width (Pn522), and the reference after applying the position reference filter is 0.
When the absolute value of the position error is below the positioning completed width (Pn522), and the position reference input is 0.
When
Enabled
After restart
Classification
Setup
4.8 Other Output Signals
4.8.7
Positioning Near Output Signal (/NEAR)
Before confirming that the positioning completed signal has been received, the host controller first receives a positioning near signal and can prepare the operating sequence after positioning has been completed. The time required for this sequence after positioning can be shortened.
This signal is generally used in combination with the positioning completed output signal.
Type
Signal
Name
Connector
Pin Number
Setting Meaning
Output /NEAR Must be allocated
ON (closed)
OFF (open)
The servomotor has reached a point near to positioning completed.
The servomotor has not reached a point near to positioning completed.
Note: Use parameter Pn510.0 to allocate the /NEAR signal for use. Refer to 3.4.2 Output Signal Allocations for details.
NEAR Signal Width
Position
Classification
Pn524
Setting Range
1 to 1073741824
Setting Unit
1 reference unit
Factory Setting
1073741824
When Enabled
Immediately Setup
The positioning near signal (/NEAR) is output when the difference between the number of references output by the host controller and the travel distance of the servomotor (position error) is less than the set value.
Motor speed Reference
Motor speed
Position error
0
/NEAR
/COIN
Pn524 Pn522 Time
Time
Time
Effective at ON (close).
Effective at ON (close).
Time
Note: Normally, the value of Pn524 should be larger than that for the positioning completed width (Pn522).
4
4-57
4-58
4 Operation
4.8.8 Speed Limit Detection Signal (/VLT)
4.8.8
Speed Limit Detection Signal (/VLT)
This function limits the speed of the servomotor to protect the machine.
A servomotor in torque control is controlled to output the specified torque, but the motor speed is not controlled. Therefore, if an excessive reference torque is set for the load torque on the machinery side, the speed of the servomotor may increase greatly. If that may occur, use this function to limit the speed.
Note: The actual limit value of motor speed depends on the load conditions of the servomotor.
With No Speed Limit With Speed Limit
Motor speed
Maximum speed
Danger of damage due to critical speed.
Motor speed
Limiting speed
Safe operation with speed limit.
Time
Time
Refer to the following parameters for speed limit.
(1) Signals Output during Servomotor Speed Limit
The following signal is output when the motor speed reaches the limit speed.
Type
Signal
Name
Connector
Pin Number
Setting Meaning
Output /VLT Must be allocated
ON (closed)
OFF (open)
Servomotor speed limit being applied.
Servomotor speed limit not being applied.
Note: Use parameter Pn50F.1 to allocate the /VLT signal for use. For details, refer to 3.4.2 Output Signal Allocations .
(2) Speed Limit Setting
Select the speed limit mode with Pn002.1.
Pn002
Parameter Meaning n.
0
[Factory setting] n.
1
VLIM (the speed limit value during torque control) is not available. Uses the value set in Pn407 as the speed limit (internal speed limit function).
VLIM operates as the speed limit value (external speed limit function).
When
Enabled
After restart
Classification
Setup
4.8 Other Output Signals
Internal Speed Limit Function
If the internal speed limit function is selected in Pn002.1, set the limit of the maximum speed of the servomotor in Pn407. The limit of the speed in Pn408.1 can be either the maximum speed of the servomotor or the overspeed alarm detection speed. Select the overspeed alarm detection speed to limit the speed to the maximum speed of the servomotor or the equivalent.
Pn407
Speed Limit During Torque Control
Setting Range
0 to 10000
Setting Unit
1 min
-1
Factory Setting
10000
Torque
When Enabled
Immediately
Classification
Setup
Note: The servomotor’s maximum speed or the overspeed alarm detection speed will be used when the setting in this parameter exceeds the maximum speed of the servomotor used.
Parameter Meaning
When
Enabled
Classification
Pn408 n.
0
[Factory setting] n.
1
Uses the smaller value of the maximum motor speed and the value of Pn407 as the speed limit value.
Uses the smaller value of the overspeed alarm detection speed and the value of Pn407 as speed limit value.
After restart Setup
External Speed Limit Function
If the external speed limit function is selected in Pn002.1, the motor speed is controlled by the speed limit value (VLIM). For details, refer to
S800000 54).
Σ -V Series User’s Manual, MECHATROLINK-II Commands (No: SIEP
4
4-59
4-60
4 Operation
4.9.1 Hard Wire Base Block (HWBB) Function
4.9
Safety Function
The safety function is incorporated in the SERVOPACK to reduce the risk associated with the machine by protecting workers from injury and by securing safe machine operation. Especially when working in hazardous areas inside the safeguard, as for machine maintenance, it can be used to avoid adverse machine movement.
4.9.1
Hard Wire Base Block (HWBB) Function
The Hard Wire Base Block function (hereinafter referred to as HWBB function) is a safety function designed to baseblock the servomotor (shut off the motor current) by using the hardwired circuits. Each circuit for two channel input signals blocks the run signal to turn off the power module that controls the motor current, and the motor current is shut off. (Refer to the diagram below.)
Power supply
Converter
24-V power supply
Switch
Fuse
0 V
/HWBB1+ 4
/HWBB1-
3
SERVOPACK
CN8
/HWBB2+
6
/HWBB2-
5
Control circuit
Run signal
Block
Block
Power module
Motor
Note: For safety function signal connections, the input signal is the 0 V common and the output signal is the source output.
This is the opposite of other signals described in this manual. To avoid confusion, the ON and OFF status of signals for safety functions are defined as follows:
ON: The state in which the relay contacts are closed or the transistor is ON and current flows into the signal line.
OFF: The state in which the relay contacts are open or the transistor is OFF and no current flows into the signal line.
(1) Risk Assessment
When using the HWBB function, be sure to perform a risk assessment of the servo system in advance. Make sure that the safety level of the standards is met. For details about the standards, refer to Harmonized Standards at the front of this manual.
Note 1. Applications for certification are pending to show that SERVOPACKs comply with rules and regulations for
North American and other safety standards, including those for safe performance.
2. To meet the performance level d (PLd) in EN ISO 13849-1, the EDM signal must be monitored by a host controller. If the EDM signal is not monitored by a host controller, the system only qualifies for the performance level c
(PLc).
The following risks can be estimated even if the HWBB function is used. These risks must be included in the risk assessment.
• The servomotor will move in an application where external force is applied to the servomotor (for example, gravity on the vertical axis). Take measures to secure the servomotor, such as installing a mechanical brake.
• The servomotor may move within the electric angle of 180 degrees in case of the power module failure, etc.
Make sure that safety is ensured even in that situation.
The maximum motor rotation angle is 1/6 of a rotation (This is the converted rotation angle for the motor shaft).
• The HWBB function does not shut off the power to the SERVOPACK and converter or electrically isolate them. Take measures to shut off the power to the SERVOPACK and converter before performing maintenance on them.
4.9 Safety Function
(2) Hard Wire Base Block (HWBB) State
The SERVOPACK will be in the following state if the HWBB function operates. If the /HWBB1 or /HWBB2 signal is OFF, the HWBB function will operate and the SERVOPACK will enter a hard wire baseblock
(HWBB) state.
The HWBB function operates after the servomotor power is turned OFF.
/HWBB1
/HWBB2
ON
(Normal operation)
OFF
(Motor current shut-off request)
M-
II command
Motion command, etc.
SV_OFF command
SMON command, etc.
Status field
SVON
1 0
IO monitor field
HBB
0
SERVOPACK state
Operation BB state
1
HWBB state
M-II
The HWBB function operates while the servomotor power is ON.
/HWBB1
/HWBB2
ON
(Normal operation)
M-
II command
Motion command, etc.
Status field
SVON
1
OFF
(Motor current shut-off request)
SMON command, etc.
0
IO monitor field
HBB
SERVOPACK state
0
Operation
1
HWBB state
4
4-61
4-62
4 Operation
4.9.1 Hard Wire Base Block (HWBB) Function
(3) Resetting the HWBB State
Usually after the servo OFF command (SV_OFF: 32H) is received and the servomotor power is OFF, the
SERVOPACK will then enter a hard wire baseblock (HWBB) state with the /HWBB1 and /HWBB2 signals turned OFF. By then turning the /HWBB1 and /HWBB2 signals ON in this state, the SERVOPACK will enter a baseblock (BB) state and can accept the servo ON command (SV_ON: 31H).
OFF
/HWBB1
/HWBB2
(Motor current shut-off request)
ON
(Normal operation)
M-II
M-
II
Command
Status field
SVON
SMON
Command, etc.
0 0
SV_ON
Command
1
IO monitor field
HBB
1 0 0
SERVOPACK state
HWBB state BB state Operation
If the /HWBB1 and /HWBB2 signals are OFF and the servo ON command is received, the HWBB state will be maintained after the /HWBB1 and /HWBB2 signals are turned ON.
Send the servo OFF command, and the SERVOPACK is placed in a BB state. Then send the servo ON command again.
/HWBB1
/HWBB2
OFF
(Motor current shut-off request)
ON
(Normal operation)
M-
II
Command
SV_ON
Command
SV_OFF
Command
SV_ON
Command
Status field
SVON
0 0
1 0
1
M-II
0
IO monitor field
HBB
SERVOPACK state
HWBB state BB state Operation
Note: Even if the servomotor power is turned OFF by turning OFF the main circuit power, the HWBB status is retained until a servo OFF command is received.
4.9 Safety Function
(4) Related Commands
If the HWBB function is working with the /HWBB1 or /HWBB2 signal turned OFF, the setting of IO monitoring field D10 (HBB) changes to 1, so the status of the upper level apparatus can be known by looking at the setting of this bit.
If the status becomes HWBB status during the execution of the next command, a command warning is issued.
If a warning is given, clear the alarm to return to normal operational status. After stopping or canceling the action command, using the sequence of commands to return to the HWBB status is recommended.
Object Action Commands
Servo ON (SV_ON)
Interpolating (INTERPORATE)
Positioning (POSING)
Constant speed feed (FEED)
Interpolating with position detection function (LATCH)
External input positioning (EX_POSING)
Homing (ZRET)
(5) Error Detection in HWBB Signal
If only the /HWBB1 or /HWBB2 signal is input, an A.Eb1 alarm (Safety Function Signal Input Timing Error) will occur unless the other signal is input within 10 seconds. This makes it possible to detect failures, such as disconnection of the HWBB signals.
CAUTION
• The safety function signal input timing error alarm (A.Eb1) is not a safety-related part of a control system. Keep this in mind in the system design.
4
4-63
4-64
4 Operation
4.9.1 Hard Wire Base Block (HWBB) Function
(6) Connection Example and Specifications of Input Signals (HWBB Signals)
The input signals must be redundant. A connection example and specifications of input signals (HWBB signals) are shown below.
For safety function signal connections, the input signal is the 0 V common and the output signal is the source output. This is opposite to other signals described in this manual. To avoid confusion, the ON and OFF status of signals for safety functions are defined as follows:
ON: The state in which the relay contacts are closed or the transistor is ON and current flows into the signal line.
OFF: The state in which the relay contacts are open or the transistor is OFF and no current flows into the signal line.
Connection Example
24-V power supply
Fuse
Use a switch that has micro-current contacts.
0 V
Switch
SERVOPACK
CN8
/HWBB1+ 4
/HWBB1- 3
/HWBB2+
6
/HWBB2-
5
Specifications
Type
Signal
Name
Connector
Pin Number
Setting Meaning
Input
/HWBB1
/HWBB2
CN8-4
CN8-3
CN8-6
CN8-5
ON (closed) Does not use the HWBB function. (normal operation)
OFF (open)
Uses the HWBB function. (motor current shut-off request)
ON (closed) Does not use the HWBB function. (normal operation)
OFF (open)
Uses the HWBB function. (motor current shut-off request)
The input signals (HWBB signals) have the following electrical characteristics.
Items
Internal Impedance
Operation Movable Voltage Range
Maximum Delay Time
3.3 k Ω
Characteristics
+11 V to + 25 V
20 ms
Remarks
−
−
Time from the /HWBB1 and /HWBB2 signals are OFF to the HWBB function operates.
If the HWBB function is requested by turning OFF the /HWBB1 and /HWBB2 input signals on the two channels, the power supply to the servomotor will be turned OFF within 20 ms (see below).
Within 20 ms
/HWBB1
/HWBB2
ON
(Normal operation)
OFF (Motor current shut-off request)
SERVOPACK
State
Normal operation HWBB state
Note 1. The OFF status is not recognized if the total OFF time of the /HWBB1 and /HWBB2 signals is 0.5 ms or shorter.
2. The status of the input signals can be checked using monitor displays. Refer to 7.5 Monitoring Safety Input Signals .
4.9 Safety Function
(7) Operation with Utility Functions
The HWBB function works while the SERVOPACK operates in the utility function.
If any of the following utility functions is being used with the /HWBB1 and /HWBB2 signals turned OFF, the
SERVOPACK cannot be operated by turning ON the /HWBB1 and /HWBB2 signals. Cancel the utility function first, and then set the SERVOPACK to the utility function again and restart operation.
• JOG operation (Fn002)
• Origin search (Fn003)
• Program JOG operation (Fn004)
• Advanced autotuning (Fn201)
• EasyFFT (Fn206)
• Automatic offset-signal adjustment of motor current detection signal (Fn00E)
(8) Servo Ready Output (/S-RDY)
The servo ON (SV_ON: 31H) command will not be accepted in the HWBB state. Therefore, the servo ready output will turn OFF. The servo ready output will turn ON if the servomotor power is OFF (set to BB state) when both the /HWBB1 and /HWBB2 signals are ON.
The following diagram shows an example where the main circuit power supply is turned ON, the Turn
Encoder Power Supply ON (SENS_ON) command is sent (with an absolute encoder), and no servo alarm occurs.
/HWBB1
/HWBB2
ON
(Normal operation)
OFF
(Motor current shut-off request)
ON
(Normal operation)
MECHA
OFF
Servomotor
Power
ON
SERVOPACK
State
Operating HWBB state BB state
/S-RDY
ON
OFF
ON
(9) Brake Signal (/BK)
When the /HWBB1 or /HWBB2 signal is OFF and the HWBB function operates, the brake signal (/BK) will turn OFF. At that time, Pn506 (brake reference - servo OFF delay time) will be disabled. Therefore, the servomotor may be moved by external force until the actual brake becomes effective after the brake signal (/BK) turns OFF.
CAUTION
• The brake signal is not a safety-related part of a control system. Be sure to design the system so that the system will not be put into danger if the brake signal fails in the HWBB state. Moreover, if a servomotor with a brake is used, keep in mind that the brake for the servomotor is used only to prevent the movable part from being moved by gravity or an external force and it cannot be used to brake the servomotor.
4
4-65
4-66
4 Operation
4.9.2 External Device Monitor (EDM1)
(10) Dynamic Brake
If the dynamic brake is enabled in Pn001.0 (Stopping Method for Servomotor after SV_OFF Command is
Received), the servomotor will come to a stop under the control of the dynamic brake when the HWBB function works while the /HWBB1 or /HWBB2 signal is OFF.
CAUTION
• The dynamic brake is not a safety-related part of a control system. Be sure to design the system so that the system will not be put into danger if the servomotor coasts to a stop in the HWBB state. Usually, use a sequence in which the HWBB state occurs after the servomotor is stopped using the reference.
• If the application frequently uses the HWBB function, do not use the dynamic brake to stop the servomotor. Otherwise element deterioration in the SERVOPACK and converter may result. To prevent internal elements from deteriorating, use a sequence in which the HWBB state occurs after the servomotor has come to a stop.
(11) Servo Alarm Output Signal (ALM)
In the HWBB state, the servo alarm output signal (ALM) is not sent.
4.9.2
External Device Monitor (EDM1)
The external device monitor (EDM1) functions to monitor failures in the HWBB function. Connect the monitor to feedback signals to the safety function device.
Note: To meet the performance level d (PLd) in EN ISO13849-1, the EDM signal must be monitored by a host controller.
If the EDM signal is not monitored by a host controller, the system only qualifies for the performance level c (PLc).
Failure Detection Signal for EDM1 Signal
The relation of the EDM1, /HWBB1, and /HWBB2 signals is shown below.
Detection of failures in the EDM1 circuit can be checked using the following four status of the EDM1 signal in the table. Failures can be detected if the failure status can be confirmed, e.g., when the power supply is turned ON.
Signal
Name
/HWBB1
/HWBB2
EDM1
ON
ON
OFF
ON
OFF
OFF
Logic
OFF
ON
OFF
OFF
OFF
ON
WARNING
• The EDM1 signal is not a safety output. Use it only for monitoring a failure.
4.9 Safety Function
(1) Connection Example and Specifications of EDM1 Output Signal
Connection example and specifications of EDM1 output signal are explained below.
For safety function signal connections, the input signal is the 0 V common and the output signal is the source output. This is opposite to other signals described in this manual. To avoid confusion, the ON and OFF status of signals for safety functions are defined as follows:
ON: The state in which the relay contacts are closed or the transistor is ON and current flows into the signal line.
OFF: The state in which the relay contacts are open or the transistor is OFF and no current flows into the signal line.
Connection Example
EDM1 output signal is used for source circuit.
SERVOPACK
CN8
Host controller
8 EDM1+
24-V power supply
7 EDM1-
0 V
Specifications
Type
Output
Signal
Name
EDM1
Connector
Pin Number
CN8-8
CN8-7
Setting
ON (closed)
OFF (open)
Meaning
Both the /HWBB1 and the /HWBB2 signals are working normally.
The /HWBB1 signal, the /HWBB2 signal or both are not working normally.
Electrical characteristics of EDM1 signal are as follows.
Items
Maximum Allowable Voltage
Maximum Current
Maximum Voltage Drop at ON
Characteristics
30 VDC
50 mADC
1.0 V
Maximum Delay Time 20 ms
Remarks
−
−
Voltage between EDM1+ and EDM1- when current is 50 mA
Time from the change in /HWBB1 or /HWBB2 until the change in EDM1
4
4-67
4-68
4 Operation
4.9.3 Application Example of Safety Functions
4.9.3
Application Example of Safety Functions
An example of using safety functions is shown below.
(1) Connection Example
In the following example, a safety unit is used and the HWBB function operates when the guard opens.
Guard
Close
Limit switch
24-V power supply
Open
Fuse
Safety unit G9SX-BC202 manufactured by OMRON Corp.
A1
Power supply input
A2
T11 T12 T21 T22
Input
Reset/feedback input
T31 T32 T33
Output
S24 S14
CN8
/HWBB1+ 4
SERVOPACK
0 V
/HWBB1-
/HWBB2+
3
6
/HWBB2- 5
EDM1+ 8
EDM17
When a guard opens, both of signals, the /HWBB1 and the /HWBB2, turn OFF, and the EDM1 signal turns
ON. Since the feedback is ON when the guard closes, the safety unit is reset, and the /HWBB1 and the /
HWBB2 signals turn ON, and the operation becomes possible.
Note: The EDM1 signal is used as a sourcing output. Connect the EDM1 so that the current flows from EMD1+ to EMD1-.
(2) Failure Detection Method
In case of a failure such as the /HWBB1 or the /HWBB2 signal remains ON, the safety unit is not reset when the guard closes because the EDM1 signal keeps OFF. Therefore starting is impossible, then the failure is detected.
In this case, an error in the external device, disconnection or short-circuiting of the external wiring, or a failure in the SERVOPACK or converter must be considered. Find the cause and correct the problem.
4.9 Safety Function
(3) Procedure
1 Request to open the guard.
2
When the servomotor is operating, the host controller stops the servomotor and sends the servo OFF command (SV_OFF).
3 Open the guard and enter.
4
The /HWBB1 and /HWBB2 signals are
OFF and HWBB function operates.
(The operation in the guard is available.)
5
After completing the operation, leave and close the guard.
6
The host controller sends the servo ON command (SV_ON).
4.9.4
Confirming Safety Functions
When starting the equipment or replacing the SERVOPACK or converter for maintenance, be sure to conduct the following confirmation test on the HWBB function after wiring.
• When the /HWBB1 and /HWBB2 signals turn OFF, check that the digital operator displays "Hbb" and that the servomotor does not operate.
• Check the ON/OFF states of the /HWBB1 and /HWBB2 signals with Un015.
→ If the ON/OFF states of the signals do not coincide with the display, an error in the external device, disconnection or short-circuiting of the external wiring, or a failure in the SERVOPACK or converter must be considered. Find the cause and correct the problem.
• Check with the display of the feedback circuit input of the connected device to confirm that the EDM1 signal is OFF while in normal operation.
4.9.5
Connecting a Safety Function Device
Connect a safety function device using the following procedure.
1.
Remove the safety function’s jumper connector from CN8.
M-II
4
Safety function’s jumper connector
Hold the jumper connector with two fingers and pull it out.
2.
Connect a safety function device to CN8.
Note: When not using the safety function, use the SERVOPACK with the safety function’s jumper connector (JZSP-
CVH05-E provided as an accessory) inserted in CN8. If the SERVOPACK is used without the jumper connector inserted into CN8, no current will flow to the servomotor and no torque will be output. In this case, "Hbb" will be displayed on the digital operator.
4-69
4-70
4 Operation
4.9.6 Precautions for Safety Functions
4.9.6
Precautions for Safety Functions
WARNING
• To check that the HWBB function satisfies the safety requirements of the system, be sure to conduct a risk assessment of the system.
Incorrect use of the machine may cause injury.
• The servomotor rotates if there is external force (e.g., gravity in a vertical axis) when the HWBB function is operating. Therefore, use an appropriate device independently, such as a mechanical brake, that satisfies safety requirements.
Incorrect use of the machine may cause injury.
• While the HWBB function is operating, the motor may rotate within an electric angle of 180 ° or less as a result of failure of the SERVOPACK or converter. Use the HWBB function for applications only after checking that the rotation of the motor will not result in a dangerous condition.
Incorrect use of the machine may cause injury.
• The dynamic brake and the brake signal are not safety-related parts of a control system. Be sure to design the system that these failures will not cause a dangerous condition when the HWBB function operates.
Incorrect use of the machine may cause injury.
• Connect devices meeting safety standards for the signals for safety functions.
Incorrect use of the machine may cause injury.
• If the HWBB function is used for an emergency stop, turn OFF the power supply to the servomotor with independent electric or mechanical parts.
Incorrect use of the machine may cause injury.
• The HWBB function does not shut off the power to the SERVOPACK and converter or electrically isolate it.
Take measures to shut off the power to the SERVOPACK and converter when performing maintenance on it.
Failure to observe this warning may cause an electric shock.
5
Adjustments
5.1 Type of Adjustments and Basic Adjustment Procedure . . . . . . . . . . . . . . 5-3
5.1.1 Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
5.1.2 Basic Adjustment Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4
5.1.3 Monitoring Operation during Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5
5.1.4 Safety Precautions on Adjustment of Servo Gains . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-8
5.2 Tuning-less Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11
5.2.1 Tuning-less Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11
5.2.2 Tuning-less Levels Setting (Fn200) Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-14
5.2.3 Related Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17
5.3 Advanced Autotuning (Fn201) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18
5.3.1 Advanced Autotuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18
5.3.2 Advanced Autotuning Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-21
5.3.3 Related Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-27
5.4 Advanced Autotuning by Reference (Fn202) . . . . . . . . . . . . . . . . . . . . . 5-28
5.4.1 Advanced Autotuning by Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-28
5.4.2 Advanced Autotuning by Reference Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-30
5.4.3 Related Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-34
5.5 One-parameter Tuning (Fn203) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-35
5.5.1 One-parameter Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-35
5.5.2 One-parameter Tuning Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-36
5.5.3 One-parameter Tuning Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-43
5.5.4 Related Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-44
5.6 Anti-Resonance Control Adjustment Function (Fn204) . . . . . . . . . . . . . 5-45
5.6.1 Anti-Resonance Control Adjustment Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-45
5.6.2 Anti-Resonance Control Adjustment Function Operating Procedure . . . . . . . . . . . . 5-46
5.6.3 Related Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-51
5.7 Vibration Suppression Function (Fn205) . . . . . . . . . . . . . . . . . . . . . . . . 5-52
5.7.1 Vibration Suppression Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-52
5.7.2 Vibration Suppression Function Operating Procedure . . . . . . . . . . . . . . . . . . . . . . . 5-53
5.7.3 Related Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-56
5
5-1
5-2
5 Adjustments
5.8 Additional Adjustment Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-57
5.8.1 Switching Gain Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-57
5.8.2 Manual Adjustment of Friction Compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-61
5.8.3 Current Control Mode Selection Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-63
5.8.4 Current Gain Level Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-63
5.8.5 Speed Detection Method Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-63
5.8.6 Backlash Compensation Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-64
5.8.7 Position Integral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-70
5.9 Compatible Adjustment Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-71
5.9.1 Feedforward Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-71
5.9.2 Mode Switch (P/PI Switching) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-72
5.9.3 Torque Reference Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-74
5.1 Type of Adjustments and Basic Adjustment Procedure
5.1
Type of Adjustments and Basic Adjustment Procedure
This section describes type of adjustments and the basic adjustment procedure.
5.1.1
Adjustments
Adjustments (tuning) are performed to optimize the responsiveness of the SERVOPACK.
The responsiveness is determined by the servo gain that is set in the SERVOPACK.
The servo gain is set using a combination of parameters, such as speed loop gain, position loop gain, filters, friction compensation, and moment of inertia ratio. These parameters influence each other. Therefore, the servo gain must be set considering the balance between the set values.
Generally, the responsiveness of a machine with high rigidity can be improved by increasing the servo gain. If the servo gain of a machine with low rigidity is increased, however, the machine will vibrate and the responsiveness may not be improved. In such case, it is possible to suppress the vibration with a variety of vibration suppression functions in the SERVOPACK.
The servo gains are factory-set to appropriate values for stable operation. The following utility function can be used to adjust the servo gain to increase the responsiveness of the machine in accordance with the actual conditions. With this function, parameters related to adjustment above will be adjusted automatically and the need to adjust them individually will be eliminated.
This section describes the following utility adjustment functions.
Utility Function for Adjustment
Tuning-less Levels Setting
(Fn200)
Advanced Autotuning (Fn201)
Advanced Autotuning by
Reference (Fn202)
One-parameter Tuning
(Fn203)
Outline
Applicable
Control Method
This function is enabled when the factory settings are used. This function can be used to obtain a stable response regardless of the type of machine or changes in the load.
The following parameters are automatically adjusted using internal references in the SERVOPACK during automatic operation.
• Moment of inertia ratio
• Gains (position loop gain, speed loop gain, etc.)
• Filters (torque reference filter, notch filter)
• Friction compensation
• Anti-resonance control adjustment function
• Vibration suppression function
The following parameters are automatically adjusted with the position reference input from the host controller while the machine is in operation.
• Gains (position loop gain, speed loop gain, etc.)
• Filters (torque reference filter, notch filter)
• Friction compensation
• Anti-resonance control adjustment function
• Vibration suppression function
The following parameters are manually adjusted with the position or speed reference input from the host controller while the machine is in operation.
• Gains (position loop gain, speed loop gain, etc.)
• Filters (torque reference filter, notch filter)
• Friction compensation
• Anti-resonance control adjustment function
Speed and Position
Speed and Position
Position
Speed and Position
Anti-Resonance Control
Adjustment Function (Fn204)
Vibration Suppression
Function (Fn205)
This function effectively suppresses continuous vibration.
This function effectively suppresses residual vibration if it occurs when positioning.
Speed and Position
Position
5
5-3
5-4
5 Adjustments
5.1.2 Basic Adjustment Procedure
5.1.2
Basic Adjustment Procedure
The basic adjustment procedure is shown in the following flowchart. Make suitable adjustments considering the conditions and operating requirements of the machine.
Start adjusting servo gain.
(1) Adjust using Tuning-less Function.
Runs the servomotor without any adjustments.
Refer to 5.2 Tuning-less Function .
Results OK?
Yes
Completed.
No
(2) Adjust using Advanced Autotuning.
Automatically adjusts the moment of inertia ratio, gains, and filters with internal references in the SERVOPACK.
Refer to 5.3 Advanced Autotuning (Fn201) .
Results OK?
Yes
Completed.
No
(3) Adjust using Advanced Autotuning by Reference.
Automatically adjusts gains and filters with user reference inputs.
Refer to 5.4 Advanced Autotuning by Reference (Fn202) .
Results OK?
Yes
Completed.
No
(4) Adjust using One-parameter Tuning.
Manually adjusts gains and filters.
Position loop gain, speed loop gain, filters, and friction compensation adjustments are available.
Refer to 5.5 One-parameter Tuning (Fn203) .
Results OK?
Yes
Completed.
No
Continuous vibration occurs.
Reduce the vibration using Anti-resonance Control Adjustment Function.
Refer to 5.6 Anti-Resonance Control Adjustment Function (Fn204) .
Residual vibration occurs at positioning.
Reduce the vibration using Vibration Suppression Function.
Refer to 5.7 Vibration Suppression Function (Fn205) .
No
Results OK?
Yes
Completed.
5.1 Type of Adjustments and Basic Adjustment Procedure
5.1.3
Monitoring Operation during Adjustment
Check the operating status of the machine and signal waveform when adjusting the servo gain. Connect a measuring instrument, such as a memory recorder, to connector CN5 analog monitor connector on the SERVO-
PACK to monitor analog signal waveform.
The settings and parameters for monitoring analog signals are described in the following sections.
(1) Connector CN5 for Analog Monitor
To monitor analog signals, connect a measuring instrument with cable (JZSP-CA01-E) to the connector CN5.
Connection Example
M-II
CN5
JZSP-CA01-E
Line Color
White
Red
Black (2 lines)
CN5
Black
Black
White
Red
Signal Name
Analog monitor 1
Analog monitor 2
GND
White
Black
Measuring probe
Probe GND
Measuring probe
Measuring instrument*
Red
Black
Probe GND
∗ Measuring instrument is not included.
Factory Setting
Torque reference: 1 V/100% rated torque
Motor speed: 1 V/1000 min
-1
Analog monitor GND: 0 V
(2) Monitor Signal
The shaded parts in the following diagram indicate analog output signals that can be monitored.
SERVOPACK
Speed feedforward
MECHA
Torque reference
Speed reference
Position reference speed
Torque feedforward
Speed reference
Position reference
Speed conversion
Position loop
Electronic gear
Backlash compensation
-
+
+
+
−
Error counter
1
Electronic gear
Position error
Positioning completed
Completion of position reference
Position amplifier error
Error counter
Kp
Motor rotational speed
+
−
1
Electronic gear
∗ Available when the fully-closed loop control is being used.
Active gain
Torque reference
+ +
−
Speed loop
+ +
Current loop
External encoder speed
∗
CN2
(U/V/W)
Error counter
Speed conversion
∗
Motor - load position error
Speed conversion
M
ENC
CN31
Load
∗
External
ENC
Fully-closed
∗ loop control
5
5-5
5-6
5 Adjustments
5.1.3 Monitoring Operation during Adjustment
The following signals can be monitored by selecting functions with parameters Pn006 and Pn007.
Pn006 is used for analog monitor 1 and Pn007 is used for analog monitor 2.
Description
Unit Remarks
Parameter
Monitor Signal n.
00
[Pn007
Factory
Setting]
Motor rotating speed n.
01 Speed reference n.
02
[Pn006
Factory
Setting]
Torque reference n.
03 Position error n.
04 Position amplifier error
Pn006
Pn007 n.
05 Position reference speed n.
06 Reserved (Do not set.) n.
07 Motor-load position error n.
08 Positioning completed n.
09 Speed feedforward n.
0A Torque feedforward n.
0B Active gain
* n.
0C Completion of position reference n.
0D External encoder speed
1 V/1000 min
-1
1 V/1000 min
-1
1 V/100% rated torque
−
−
−
0.05 V/1 reference unit 0 V at speed/torque control
0.05 V/1 encoder pulse unit
Position error after electronic gear conversion
1 V/1000 min
-1
−
0.01 V/1 reference unit
−
−
−
Positioning completed:
5 V
Positioning not completed: 0 V
1 V/1000 min
-1
Completion indicated by output voltage.
1 V/100% rated torque
1st gain: 1 V
2nd gain: 2 V
Completed: 5 V
Not completed: 0 V
1 V/1000 min
-1
−
−
Gain type indicated by output voltage.
Completion indicated by output voltage.
Value at motor shaft
∗ Refer to 5.8.1 Switching Gain Settings for details.
5.1 Type of Adjustments and Basic Adjustment Procedure
(3) Setting Monitor Factor
The output voltages on analog monitors 1 and 2 are calculated by the following equations.
Analog monitor 1 output voltage = (-1)
Analog monitor 2 output voltage = (-1)
×
×
Signal selection
(Pn006=n.00
غغ )
Signal selection
(Pn007=n.00
غغ )
×
Multiplier + Offset voltage [V]
(Pn552)
(Pn550)
×
Multiplier + Offset voltage [V]
(Pn553) (Pn551)
<Example>
Analog monitor output at n.
00 (motor rotating speed setting)
When multiplier is set to
×
1:
Analog monitor output voltage [V]
+6 V
When multiplier is set to
×
10:
Analog monitor output voltage[V]
+10 V (approx.)
+8 V
+6 V
Rotation
-6000
+6000 Motor speed
[min -1 ]
-800 -600
+600 +800 Motor speed
[min -1 ]
-6 V
-6 V
-8 V
-10 V (approx.)
Note: Linear effective range: within ± 8 V
Output resolution: 16-bit
(4) Related Parameters
Use the following parameters to change the monitor factor and the offset.
Pn550
Pn551
Pn552
Pn553
Analog Monitor 1 Offset Voltage
Setting Range
-10000 to 10000
Setting Unit
0.1 V
Analog Monitor 2 Offset Voltage
Setting Range
-10000 to 10000
Setting Unit
0.1 V
Analog Monitor Magnification ( × 1)
Setting Range
-10000 to 10000
Setting Unit
× 0.01
Analog Monitor Magnification ( × 2)
Setting Range
-10000 to 10000
Setting Unit
× 0.01
Speed
Factory Setting
0
Speed
Factory Setting
0
Speed
Factory Setting
100
Speed
Factory Setting
100
Position Torque
When Enabled
Immediately
Position Torque
When Enabled
Immediately
Position Torque
When Enabled
Immediately
Position Torque
When Enabled
Immediately
Classification
Setup
Classification
Setup
Classification
Setup
Classification
Setup 5
5-7
5-8
5 Adjustments
5.1.4 Safety Precautions on Adjustment of Servo Gains
5.1.4
Safety Precautions on Adjustment of Servo Gains
CAUTION
• If adjusting the servo gains, observe the following precautions.
• Do not touch the rotating section of the servomotor while power is being supplied to the motor.
• Before starting the servomotor, make sure that the SERVOPACK can come to an emergency stop at any time.
• Make sure that a trial operation has been performed without any trouble.
• Install a safety brake on the machine.
Set the following protective functions of the SERVOPACK to the correct settings before starting to adjust the servo gains.
(1) Overtravel Function
Set the overtravel function. For details on how to set the overtravel function, refer to 4.3.2 Overtravel .
(2) Torque Limit
The torque limit calculates the torque required to operate the machine and sets the torque limits so that the output torque will not be greater than required. Setting torque limits can reduce the amount of shock applied to the machine when troubles occur, such as collisions or interference. If a torque limit is set lower than the value that is needed for operation, overshooting or vibration can be occurred.
For details, refer to 4.6 Limiting Torque .
(3) Excessive Position Error Alarm Level
The excessive position error alarm is a protective function that will be enabled when the SERVOPACK is used in position control.
If this alarm level is set to a suitable value, the SERVOPACK will detect an excessive position error and will stop the servomotor if the servomotor does not operate according to the reference. The position error indicates the difference between the position reference value and the actual motor position.
The position error can be calculated from the position loop gain (Pn102) and the motor speed with the following equation.
Position Error [reference unit] =
Motor Speed [min ]
60
Encoder Resolution *1
Pn102 [0.1/s]/10 *2, *3
• Excessive Position Error Alarm Level (Pn520 [1 reference unit])
Pn210
Pn20E
Rotation
Pn520 >
60
×
Encoder Resolution
Pn102 [0.1/s]/10
*1
*2, *3
×
Pn210
Pn20E
× (1.2 to 2) *4
Rotation
∗1.
Refer to 4.4.3 Electronic Gear .
∗2.
When model following control is enabled (Pn140 is set to n.
1), use the set value of Pn141 and not that of
Pn102.
∗3.
To check the Pn102 setting, change the parameter display setting to display all parameters (Pn00B.0 = 1).
∗4.
At the end of the equation, a coefficient is shown as " × (1.2 to 2)." This coefficient is used to add a margin that prevents a position error overflow alarm (A.d00) from occurring in actual operation of the servomotor.
Set the level to a value that satisfies these equations, and no position error overflow alarm (A.d00) will be generated during normal operation. The servomotor will be stopped, however, if it does not operate according to the reference and the SERVOPACK detects an excessive position error.
The following example outlines how the maximum limit for position deviation is calculated. These conditions apply.
• Maximum speed = 6000
• Encoder resolution = 1048576 (20 bits)
• Pn102 = 400
•
Pn210
Pn20E
=
1
1
Under these conditions, the following equation is used to calculate the maximum limit (Pn520).
5.1 Type of Adjustments and Basic Adjustment Procedure
Pn520 =
=
6000
60
×
1048576
400/10
2621440 × 2
×
1
1
× 2
Rotation
= 5242880 (The factory setting of Pn520)
If the acceleration/deceleration of the position reference exceeds the capacity of the servomotor, the servomotor cannot perform at the requested speed, and the allowable level for position error will be increased as not to satisfy these equations. If so, lower the level of the acceleration/deceleration for the position reference so that the servomotor can perform at the requested speed or increase the excessive position error alarm level
(Pn520).
Related Parameter
Pn520
Excessive Position Error Alarm Level
Setting Range
1 to 1073741823
Setting Unit
1 reference unit
Related Alarm
Position
Factory Setting
5242880
When Enabled
Immediately
Classification
Setup
Alarm
Display
A.d00
Alarm Name Meaning
Position Error Overflow Position errors exceeded parameter Pn520.
(4) Vibration Detection Function
Set the vibration detection function to an appropriate value with the vibration detection level initialization
(Fn01B). For details on how to set the vibration detection function, refer to 6.16 Vibration Detection Level
Initialization (Fn01B) .
(5) Excessive Position Error Alarm Level at Servo ON
If position errors remain in the error counter when turning ON the servomotor power, the servomotor will move and this movement will clear the counter of all position errors. Because the servomotor will move suddenly and unexpectedly, safety precautions are required. To prevent the servomotor from moving suddenly, select the appropriate level for the excessive position error alarm level at servo ON (Pn526) to restrict operation of the servomotor.
Related Parameters
Pn526
Excessive Position Error Alarm Level at Servo ON
Setting Range
1 to 1073741823
Setting Unit
1 reference unit
Position
Factory Setting
5242880
When Enabled
Immediately
Classification
Setup
Pn528
Excessive Position Error Warning Level at Servo ON
Setting Range
10 to 100
Setting Unit
1%
Position
Factory Setting
100
When Enabled
Immediately
Classification
Setup
Pn529
Speed Limit Level at Servo ON
Setting Range
0 to 10000
Setting Unit
1 min
-1
Position
Factory Setting
10000
When Enabled
Immediately
Classification
Setup
5
5-9
5-10
5 Adjustments
5.1.4 Safety Precautions on Adjustment of Servo Gains
Related Alarms
Alarm
Display
Alarm Name Meaning
A.d01
A.d02
Position Error Overflow
Alarm at Servo ON
Position Error Overflow
Alarm by Speed Limit at
Servo ON
This alarm occurs if the servomotor power is turned ON when the position error is greater than the set value of Pn526 while the servomotor power is
OFF.
When the position errors remain in the error counter, Pn529 limits the speed if the servomotor power is turned ON. If Pn529 limits the speed in such a state, this alarm occurs when position references are input and the number of position errors exceeds the value set for the excessive position error alarm level (Pn520).
When an alarm occurs, refer to 9 Troubleshooting and take the corrective actions.
5.2 Tuning-less Function
5.2
Tuning-less Function
The tuning-less function is enabled in the factory settings. If resonance is generated or excessive vibration occurs, refer to 5.2.2 Tuning-less Levels Setting (Fn200) Procedure and change the set value of Pn170.2 for the rigidity level and the set value in Pn170.3 for the load level.
CAUTION
• The tuning-less function is enabled in the factory settings. A sound may be heard for a moment when the
SV_ON command is received for the first time after the servo drive is mounted to the machine. This sound does not indicate any problems; it means that the automatic notch filter was set. The sound will not be heard from the next time the SV_ON command is received. For details on the automatic notch filter, refer to (3) Automatically Setting the Notch Filter on the next page.
• The servomotor may vibrate if the load moment of inertia exceeds the allowable load value.
If vibration occurs, set the mode to 2 in Fn200 or lower the adjustment level.
5.2.1
Tuning-less Function
The tuning-less function obtains a stable response without manual adjustment regardless of the type of machine or changes in the load.
(1) Enabling/Disabling Tuning-less Function
The following parameter is used to enable or disable the tuning-less function.
Pn170
Parameter n.
0 n.
1
Meaning
Disables tuning-less function.
n.
1
[Factory setting] Enables tuning-less function. n.
0
[Factory setting]
Used as speed control.
Used as speed control and host controller used as position control.
When Enabled Classification
After restart Setup
(2) Application Restrictions
The tuning-less function can be used in position control or speed control. This function is not available in torque control. The following application restrictions apply to the tuning-less function.
Vibration detection level initialization
(Fn01B)
Function
Advanced autotuning (Fn201)
Advanced autotuning by reference (Fn202)
One-parameter tuning (Fn203)
Anti-resonance control adjustment function (Fn204)
Vibration suppression function (Fn205)
EasyFFT (Fn206)
Friction compensation
Availability
Available
Available
(Some conditions apply)
Not available
Not available
Not available
Not available
Available
Not available
Remarks
–
• This function can be used when the moment of inertia is calculated.
• While this function is being used, the tuning-less function cannot be used. After completion of the autotuning, it can be used again.
–
–
–
–
While this function is being used, the tuningless function cannot be used. After completion of the EasyFFT, it can be used again.
–
5
5-11
5-12
5 Adjustments
5.2.1 Tuning-less Function
Function
Gain switching
Offline moment of inertia calculation
*
Mechanical analysis *
Availability
Not available
Not available
Available
(cont’d)
Remarks
–
Disable the tuning-less function by setting
Pn170.0 to 0 before executing this function.
While this function is being used, the tuningless function cannot be used. After completion of the analysis, it can be used again.
∗ Operate using SigmaWin+.
(3) Automatically Setting the Notch Filter
Usually, set this function to Auto Setting. (The notch filter is factory-set to Auto Setting.)
If this function is set to Auto Setting, vibration will be detected automatically and the notch filter will be set when the tuning-less function is enabled.
Set this function to Not Auto Setting only if you do not change the notch filter setting before executing tuningless function.
Pn460
Parameter n. 0 n. 1
[Factory setting]
Meaning
Does not set the 2nd notch filter automatically with utility function.
Set the 2nd notch filter automatically with utility function.
When Enabled Classification
Immediately Tuning
(4) Tuning-less Level Settings
Two tuning-less levels are available: the rigidity level and load level. Both levels can be set in the Fn200 utility function or in the Pn170 parameter.
Rigidity Level a) Using the utility function
To change the setting, refer to 5.2.2 Tuning-less Levels Setting (Fn200) Procedure .
Digital Operator Display
Level 0
Level 1
Level 2
Level 3
Level 4 [Factory setting]
Rigidity level 0
Rigidity level 1
Rigidity level 2
Rigidity level 3
Rigidity level 4
Meaning b) Using the parameter
Pn170
Parameter n. 0 n. 1 n. 2 n. 3 n. 4
[Factory setting]
Meaning
Rigidity level 0 (Level 0)
Rigidity level 1 (Level 1)
Rigidity level 2 (Level 2)
Rigidity level 3 (Level 3)
Rigidity level 4 (Level 4)
When Enabled Classification
Immediately Setup
5.2 Tuning-less Function
Load Level a) Using the utility function
To change the setting, refer to 5.2.2 Tuning-less Levels Setting (Fn200) Procedure .
Digital Operator Display
Mode 0
Mode 1 [Factory setting]
Mode 2
Load level : Low
Load level : Medium
Load level : High
Meaning b) Using the parameter
Pn170
Parameter n.0
Meaning
Load level : Low (Mode 0) n.1
[Factory setting] Load level : Medium (Mode 1) n.2
Load level : High (Mode 2)
When Enabled Classification
Immediately Setup
5
5-13
5-14
5 Adjustments
5.2.2 Tuning-less Levels Setting (Fn200) Procedure
5.2.2
Tuning-less Levels Setting (Fn200) Procedure
CAUTION
• To ensure safety, perform the tuning-less function in a state where the SERVOPACK can come to an emergency stop at any time.
The procedure to use the tuning-less function is given below.
Operate the tuning-less function from the digital operator (option) or SigmaWin+.
For the basic operation of the digital operator, refer to tor (No.: SIEP S800000 55).
Σ -V Series User’s Manual, Operation of Digital Opera-
(1) Preparation
Check the following settings before performing the tuning-less function. If the settings are not correct, "NO-
OP" will be displayed during the tuning-less function.
• The tuning-less function must be enabled (Pn170.0 = 1).
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
• The test without a motor function must be disabled. (Pn00C.0 = 0).
(2) Operating Procedure with Digital Operator
Keys Step
1
Display after Operation
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧜㧤㧜㧦㧼㨛㨘㨑ޓ㧰㨑㨠㨑㨏㨠
㧲㨚㧞㧜㧜㧦㨀㨡㨚㨑㧸㨢㨘ޓ㧿㨑㨠
㧲㨚㧞㧜㧝㧦㧭㧭㨀
㧲㨚㧞㧜㧞㧦㧾㨑㨒㧙㧭㧭㨀
2
㧾㨁㧺 ̆㨀㨡㨚㨑㧸㨢㨘㧿㨑㨠̆
ޓ㧹㨛㨐㨑㧩
3
㧾㨁㧺 ̆㨀㨡㨚㨑㧸㨢㨘㧿㨑㨠̆
ޓ㧸㨑㨢㨑㨘㧩㧠
4
㧾㨁㧺 ̆㨀㨡㨚㨑㧸㨢㨘㧿㨑㨠 ̆
ޓ㧸㨑㨢㨑㨘㧩㧠
ޓޓޓޓޓ㧺㧲㧞
2nd notch filter
5
㧾㨁㧺 ̆㨀㨡㨚㨑㧸㨢㨘㧿㨑㨠̆
ޓ㧸㨑㨢㨑㨘㧩㧠
Operation
Press the Key to view the main menu for the utility function.
Use the select Fn200.
or Key to move through the list,
Press the Key to display the load level setting screen for Fn200 (Tuning-less Levels setting).
Notes:
• If the response waveform causes overshooting or if the load moment of inertia exceeds the allowable level (i.e., outside the scope of product guarantee), press the Key and change the mode setting to
2.
• If a high-frequency noise is heard, press the
Key and change the mode setting to 0.
Press the Key to display the rigidity level of the tuning-less mode setting screen.
Press the Key or the ity level.
Key to select the rigid-
Select the rigidity level from 0 to 4. The larger the value, the higher the gain is and the better response performance will be. (The factory setting is 4.)
Notes:
• Vibration may occur if the rigidity level is too high.
Lower the rigidity level if vibration occurs.
• If a high-frequency noise is heard, press the
Key to automatically set a notch filter to the vibration frequency.
Press the Key. “DONE” will flash for approximately two seconds and then “RUN” will be displayed. The settings are saved in the SERVOPACK.
5.2 Tuning-less Function
(cont’d)
Step Display after Operation Keys Operation
6
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧜㧟㧜
㧲㨚㧞㧜㧜
㧲㨚㧞㧜㧝
㧲㨚㧞㧜㧞
Press the Key to complete the tuning-less function. The screen in step 1 will appear again.
Note: If the rigidity level is changed, the automatically set notch filter will be canceled. If vibration occurs, however, the notch filter will be set again automatically.
(3) Alarm and Corrective Actions
The autotuning alarm (A.521) will occur if resonance sound is generated or excessive vibration occurs during position control. In such case, take the following actions.
Resonance Sound
Reduce the setting of the rigidity level or load level.
Excessive Vibration during Position Control
Take one of the following actions to correct the problem.
• Increase the setting of the rigidity level or reduce the load level.
• Increase the setting of Pn170.3 or reduce the setting of Pn170.2.
(4) Parameters Disabled by Tuning-less Function
When the tuning-less function is enabled in the factory settings, the settings of these parameters are not available: Pn100, Pn101, Pn102, Pn103, Pn104, Pn105, Pn106, Pn160, Pn139, and Pn408. These gain-related parameters, however, may become effective depending on the executing conditions of the functions specified in the following table. For example, if EasyFFT is executed when the tuning-less function is enabled, the settings in Pn100, Pn104, Pn101, Pn105, Pn102, Pn106, and Pn103, as well as the manual gain switch setting, will be enabled, but the settings in Pn408.3, Pn160.0, and Pn139.0 will be not enabled
.
Item
Parameters Disabled by Tuning-less Function
Name Pn Number
Related Functions and Parameters*
Torque
Control
Easy
FFT
Mechanical
Analysis (Vertical Axis
Mode)
Gain
Advanced
Control
Speed Loop Gain
2nd Speed Loop Gain
Speed Loop Integral Time Constant
2nd Speed Loop Integral Time Constant
Position Loop Gain
2nd Position Loop Gain
Moment of Inertia Ratio
Friction Compensation Function Selection
Anti-resonance Control Adjustment
Selection
Gain Switching
Gain Switching Selection Switch
∗ : Parameter enabled
× : Parameter disabled
Pn100
Pn104
Pn101
Pn105
Pn102
Pn106
Pn103
Pn408.3
Pn160.0
Pn139.0
×
×
×
×
×
×
×
×
×
×
×
5
5-15
5-16
5 Adjustments
5.2.2 Tuning-less Levels Setting (Fn200) Procedure
(5) Tuning-less Function Type
The following table shows the types of tuning-less functions for the version of SERVOPACK software.
Tuning-less Type
Tuning-less type 1
Tuning-less type 2
Meaning
−
The level of noise produced is lower than that of Type 1.
Pn14F
Parameter n.
0 n.
1
[Factory setting]
Meaning
Tuning-less type 1
Tuning-less type 2
When Enabled Classification
After restart Tuning
5.2 Tuning-less Function
5.2.3
Related Parameters
The following table lists parameters related to this function and their possibility of being changed while executing this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes : Parameters can be changed using SigmaWin+ while this function is being executed.
No : Parameters cannot be changed using SigmaWin+ while this function is being executed.
• Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
Parameter
Pn170
Pn401
Pn40C
Pn40D
Name
Tuning-less Function Related Switch
Torque Reference Filter Time Constant
2nd Notch Filter Frequency
2nd Notch Filter Q Value
Mid-execution changes
No
No
No
No
Automatic changes
Yes
Yes
Yes
Yes
5
5-17
5-18
5 Adjustments
5.3.1 Advanced Autotuning
5.3
Advanced Autotuning (Fn201)
This section describes the adjustment using advanced autotuning.
• Advanced autotuning starts adjustments based on the set speed loop gain (Pn100).
Therefore, precise adjustments cannot be made if there is vibration when starting adjustments. In this case, make adjustments after lowering the speed loop gain
(Pn100) until vibration is eliminated.
• Before performing advanced autotuning with the tuning-less function enabled
(Pn170.0 = 1: Factory setting), always set Jcalc to ON to calculate the load moment of inertia. The tuning-less function will automatically be disabled, and the gain will be set by advanced autotuning.
With Jcalc set to OFF so the load moment of inertia is not calculated, "Error" will be displayed on the panel operator, and advanced autotuning will not be performed.
• If the operating conditions, such as the machine-load or drive system, are changed after advanced autotuning, then change the following related parameters to disable any values that were adjusted before performing advanced autotuning once again with the setting to calculate the moment of inertia (Jcalc = ON). If advanced autotuning is performed without changing the parameters, machine vibration may occur, resulting in damage to the machine.
Pn00B.0 = 1 (Displays all parameters.)
Pn140.0 = 0 (Does not use model following control.)
Pn160.0 = 0 (Does not use anti-resonance control.)
Pn408 = n.00 0 (Does not use friction compensation, 1st notch filter, or 2nd notch filter.)
5.3.1
Advanced Autotuning
Advanced autotuning automatically operates the servo system (in reciprocating movement in the forward and reverse directions) within set limits and adjust the SERVOPACK automatically according to the mechanical characteristics while the servo system is operating.
Advanced autotuning can be performed without connecting the host controller.
The following automatic operation specifications apply.
• Maximum speed: Rated motor speed × 2/3
• Acceleration torque: Approximately 100% of rated motor torque
The acceleration torque varies with the influence of the moment of inertia ratio
(Pn103), machine friction, and external disturbance.
• Travel distance: The travel distance can be set freely. The distance is factory-set to a value equivalent to 3 motor rotations.
Movement speed
M-II
Rated motor speed
×
2/3
Rotation
Travel distance t: time
Reference
Response
SERVOPACK
Execute advanced autotuning after a JOG operation to move the position to ensure a suitable movement range.
Rated motor speed
×
2/3
Rated motor torque
Approx. 100%
Rated motor torque
Approx. 100%
Automatic operation t: time
5.3 Advanced Autotuning (Fn201)
Advanced autotuning performs the following adjustments.
• Moment of inertia ratio
• Gains (e.g., position loop gain and speed loop gain)
• Filters (torque reference filter and notch filter)
• Friction compensation
• Anti-resonance control
• Vibration suppression (Mode = 2 or 3)
Refer to 5.3.3 Related Parameters for parameters used for adjustments.
CAUTION
• Because advanced autotuning adjusts the SERVOPACK during automatic operation, vibration or overshooting may occur. To ensure safety, perform advanced autotuning in a state where the SERVOPACK can come to an emergency stop at any time.
(1) Preparation
Check the following settings before performing advanced autotuning.
The message “NO-OP” indicating that the settings are not appropriate will be displayed, if all of the following conditions are not met.
• The main circuit power supply must be ON.
• There must be no overtravel.
• The servomotor power must be OFF.
• The control method must not be set to torque control.
• The gain selection switch must be in manual switching mode (Pn139.0 = 0).
• Gain setting 1 must be selected.
• The test without a motor function must be disabled (Pn00C.0 = 0).
• All alarms and warning must be cleared.
• The hardwire baseblock (HWBB) must be disabled.
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
• Jcalc must be set to ON to calculate the load moment of inertia when the tuning-less function is enabled
(Pn170.0 = 1: factory setting) or the tuning-less function must be disabled (Pn170.0 = 0).
Note:
• If advanced autotuning is started while the SERVOPACK is in speed control, the mode will change to position control automatically to perform advanced autotuning. The mode will return to speed control after completing the adjustment. To perform advanced autotuning in speed control, set the mode to 1 (Mode = 1).
(2) When Advanced Autotuning Cannot Be Performed
Advanced autotuning cannot be performed normally under the following conditions. Refer to 5.4 Advanced
Autotuning by Reference (Fn202) and 5.5 One-parameter Tuning (Fn203) for details.
• The machine system can work only in a single direction.
• The operating range is within 0.5 rotation.
5
5-19
5-20
5 Adjustments
5.3.1 Advanced Autotuning
(3) When Advanced Autotuning Cannot Be Performed Successfully
Advanced autotuning cannot be performed successfully under the following conditions. Refer to 5.4
Advanced Autotuning by Reference (Fn202) and 5.5 One-parameter Tuning (Fn203) for details.
• The operating range is not applicable.
• The moment of inertia changes within the set operating range.
• The machine has high friction.
• The rigidity of the machine is low and vibration occurs when positioning is performed.
• The position integration function is used.
• P control operation (proportional control) is used.
Note:If a setting is made for calculating the moment of inertia, an error will result when P control operation is selected using /V_PPI of OPTION field while the moment of inertia is being calculated.
• The mode switch is used.
Note:If a setting is made for calculating the moment of inertia, the mode switch function will be disabled while the moment of inertia is being calculated. At that time, PI control will be used. The mode switch function will be enabled after calculating the moment of inertia.
• Speed feedforward or torque feedforward is input.
• The positioning completed width (Pn522) is too small.
• Advanced autotuning makes adjustments by referring to the positioning completed width (Pn522). If the SERVOPACK is operated in position control (Pn000.1=1), set the electronic gear ratio (Pn20E/Pn210) and positioning completed width (Pn522) to the actual value during operation. If the SERVOPACK is operated in speed control
(Pn000.1=0), set Mode to 1 to perform advanced autotuning.
• Unless the positioning completed signal (/COIN) is turned ON within approximately 3 seconds after positioning has been completed, "WAITING" will flash. Furthermore, unless the positioning completed signal (/COIN) is turned ON within approximately 10 seconds, "Error" will flash for 2 seconds and tuning will be aborted.
Change only the overshoot detection level (Pn561) to finely adjust the amount of overshooting without changing the positioning completed width (Pn522). Because Pn561 is set by default to 100%, the allowable amount of overshooting is the same amount as that for the positioning completed width.
When Pn561 is set to 0%, the amount of overshooting can be adjusted to prevent overshooting the positioning completed width. If the setting of Pn561 is changed, however, the positioning time may be extended.
Pn561
Overshoot Detection Level
Setting Range
0 to 100
Setting Unit
1%
Speed Position Torque
Factory Setting
100
When Enabled
Immediately
Classification
Setup
5.3 Advanced Autotuning (Fn201)
5.3.2
Advanced Autotuning Procedure
The following procedure is used for advanced autotuning.
Advanced autotuning is performed from the digital operator (option) or SigmaWin+.
The operating procedure from the digital operator is described here.
Refer to the Σ -V Series User’s Manual, Operation of Digital Operator operations of the digital operator.
(No.: SIEP S800000 55) for basic key
CAUTION
• When using the SERVOPACK with Jcalc = OFF (moment of inertia is not calculated), be sure to set a suitable value for the moment of inertia ratio (Pn103). If the setting greatly differs from the actual moment of inertia ratio, normal control of the SERVOPACK may not be possible, and vibration may result.
• When using the MP2000 Series with phase control, select the mode = 1 (standard level). If 2 or 3 is selected, phase control of the MP2000 Series may not be possible.
(1) Operating Procedure
Step
1
2
Display after Operation
㧮㧮 ޓ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧜㧦㨀㨡㨚㨑㧸㨢㨘ޓ㧿㨑㨠
㧲㨚㧞㧜㧝㧦㧭㧭㨀
㧲㨚㧞㧜㧞㧦㧾㨑㨒㧭㧭㨀
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
Status Display
㧮㧮 㧭㨐㨢㨍㨚㨏㨑㨐ޓ㧭㨀
ޓ㧶㨏㨍㨘㨏㧩㧻㧺
ޓ㧹 㨛 㨐 㨑㧩㧞ޓ㨀㨥㨜㨑㧩㧞
ޓ㧿㨠㨞㨛㨗㨑㧩㧗㧜㧜㧤㧜㧜㧜㧜㧜
ޓޓޓޓޓޓ㧔㧜㧜㧜㧟㧚㧜㧕㨞㨑㨢
Keys Operation
Press the Key to view the main menu for the utility function.
Use the or Key to move through the list, select Fn201.
Press the Key to display the initial setting screen for Fn201(Advanced Autotuning).
3
3-1
3-2
3-3
㧮㧮 㧭㨐㨢㨍㨚㨏㨑㨐ޓ㧭㨀
ޓ㧶㨏㨍㨘㨏㧩㧻㧺
ޓ㧹 㨛 㨐 㨑㧩㧞ޓ㨀㨥㨜㨑㧩㧞
ޓ㧿㨠㨞㨛㨗㨑㧩㧗㧜㧜㧤㧜㧜㧜㧜㧜
ޓޓޓޓޓޓ㧔㧜㧜㧜㧟㧚㧜㧕㨞㨑㨢
Press the , steps 3-1 to 3-4.
, or Key and set the items in
Calculating Moment of Inertia
Select the mode to be used.
Usually, set Jcalc to ON.
Jcalc = ON: Moment of inertia calculated [Factory setting]
Jcalc = OFF: Moment of inertia not calculated
Note:
If the moment of inertia ratio is already known from the machine specifications, set the value in Pn103 and set Jcalc to OFF.
Mode Selection
Select the mode.
Mode = 1: Makes adjustments considering response characteristics and stability (Standard level).
Mode = 2: Makes adjustments for positioning [Factory setting].
Mode = 3: Makes adjustments for positioning, giving priority to overshooting suppression.
Type Selection
Select the type according to the machine element to be driven. If there is noise or the gain does not increase, better results may be obtained by changing the rigidity type.
Type = 1: For belt drive mechanisms
Type = 2: For ball screw drive mechanisms [Factory setting]
Type = 3: For rigid systems in which the servomotor is directly coupled to the machine (without gear or other
transmissions)
5
5-21
5-22
5 Adjustments
5.3.2 Advanced Autotuning Procedure
Step
3-4
(cont’d)
Display after Operation Keys Operation
STROKE (Travel Distance) Setting
Travel distance setting range:
The travel distance setting range is from -99990000 to +99990000 [reference unit]. Specify the STROKE
(travel distance) in increments of 1000 reference units. The negative (-) direction is for reverse rotation, and the positive (+) direction is for forward rotation.
Initial value:
About 3 rotations
Notes:
• Set the number of motor rotations to at least 0.5; otherwise, "Error" will be displayed and the travel distance cannot be set.
• To calculate the moment of inertia and ensure precise tuning, it is recommended to set the number of motor rotations to around 3.
4
㧮㧮 㧭 㨐㨢㨍㨚㨏㨑㨐 㧭㨀
㧼㨚㧝㧜㧟㧩㧜㧜㧝㧜㧜
㧼㨚㧝㧜㧜㧩㧜㧜㧠㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧞㧜㧜㧜
㧼㨚㧝㧜㧞㧩㧜㧜㧠㧜㧜
Press the Key. The advanced autotuning execution screen will be displayed.
5
6
7
R U N 㧭 㨐㨢㨍㨚㨏㨑㨐 㧭㨀
㧼㨚㧝㧜㧟㧩㧜㧜㧝㧜㧜
㧼㨚㧝㧜㧜㧩㧜㧜㧠㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧞㧜㧜㧜
㧼㨚㧝 㧠 㧝㧩㧜㧜㧡㧜㧜
㧭㧰㧶 㧭㨐㨢㨍㨚㨏㨑㨐 㧭㨀
㧼㨚㧝㧜㧟㧩㧜㧜㧟㧜㧜
㧼㨚㧝㧜㧜㧩㧜㧜㧠㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧞㧜㧜
㧼㨚㧝㧠㧝㧩㧜㧜㧡㧜㧜
Display example:
After the moment of inertia is calculated.
–
Press the Key. The servomotor power will be
ON and the display will change from "BB" to
"RUN."
Note: If the mode is set to 1, Pn102 is displayed. If the mode is set to 2 or 3, the Pn102 display will change to the Pn141.
Calculates the moment of inertia.
Press the Key if a positive (+) value is set in
STROKE (travel distance), or press the Key if a negative (-) value is set. Calculation of the moment of inertia will start. While the moment of inertia is being calculated, the set value for Pn103 will flash and
“ADJ” will flash instead of “RUN.” When calculating the moment of inertia is completed, the display will stop flashing and the moment of inertia is displayed. The servomotor will remain ON, but the auto run operation will be stopped temporarily.
Notes:
• The wrong key for the set travel direction is pressed, the calculation will not start.
• If the moment of inertia is not calculated (Jcalc =
OFF), the set value for Pn103 will be displayed.
• If "NO-OP" or "Error" is displayed during operation, press the Key to cancel the function.
Refer to (2) Failure in Operation and take a corrective action to enable operation.
After the servomotor is temporarily stopped, press the
Key to save the calculated moment of inertia ratio in the SERVOPACK. “DONE” will flash for one second, and “ADJ” will be displayed again.
Note:
To end operation by calculating only the moment of inertia ratio and without adjusting the gain, press the Key to end operation.
5.3 Advanced Autotuning (Fn201)
Step
8
Display after Operation
A 㧰㧶 㧭 㨐㨢㨍㨚㨏㨑㨐 㧭㨀
㧼㨚㧝㧜㧟㧩㧜㧜㧟㧜㧜
㧼㨚㧝㧜㧜㧩㧜㧝㧜㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧜㧢㧟㧢
㧼㨚㧝㧠㧝㧩㧜㧝㧡㧜㧜
Keys
(cont’d)
Operation
Gain Adjustment
When the or Key is pressed according to the sign (+ or -) of the value set for stroke (travel distance), the calculated value of the moment of inertia ratio will be saved in the SERVOPACK and the auto run operation will restart. While the servomotor is running, the filters, and gains will be automatically set. "ADJ" will flash during the auto setting operation.
Note: Precise adjustments cannot be made and
"Error" will be displayed as the status if there is machine resonance when starting adjustments.
If that occurs, make adjustments using oneparameter tuning (Fn203).
When the adjustment has been completed normally, the servomotor power will turn OFF, and "END" will flash for approximately two seconds and then "ADJ" will be displayed on the status display.
9
㧭㧰㧶 㧭 㨐㨢㨍㨚㨏㨑㨐 㧭㨀
㧼㨚㧝㧜㧟㧩㧜㧜㧟㧜㧜
㧼㨚㧝㧜㧜㧩㧜㧝㧜㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧜㧢㧟㧢
㧼㨚㧝㧠㧝㧩㧜㧝㧡㧜㧜
10
㧮㧮 㧭㨐㨢㨍㨚㨏㨑㨐 㧭㨀
㧼㨚㧝㧜㧟㧩㧜㧜㧟㧜㧜
ME
㧼㨚㧝㧜㧜㧩㧜㧝㧜㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧜㧢㧟㧢
㧼㨚㧝㧠㧝㧩㧜㧝㧡㧜㧜
CHA
Press the Key. The adjusted values will be saved in the SERVOPACK.
"DONE" will flash for approximately two seconds, and "BB" will be displayed.
Note: Press the Key to not save the values. The display will return to that shown in step 1.
11 Turn ON the SERVOPACK power supply again after executing advanced autotuning.
(2) Failure in Operation
When "NO-OP" Flashes on the Display
Probable Cause
The main circuit power supply was OFF.
An alarm or warning occurred.
Overtraveling occurred.
Gain setting 2 was selected by gain switching.
The HWBB function operated.
Corrective Actions
Turn ON the main circuit power supply.
Remove the cause of the alarm or the warning.
Remove the cause of the overtravel.
Disable the automatic gain switching.
Disable the HWBB function.
5
5-23
5-24
5 Adjustments
5.3.2 Advanced Autotuning Procedure
When "Error" Flashes on the Display
Error
The gain adjustment was not successfully completed.
Machine vibration is occurring or the positioning completed signal (/COIN) is turning
ON and OFF when the servomotor is stopped.
Probable Cause Corrective Actions
• Increase the set value for Pn522.
• Change the mode from 2 to 3.
• If machine vibration occurs, suppress the vibration with the anti-resonance control adjustment function and the vibration suppression function.
An error occurred during the calculation of the moment of inertia.
Refer to the following table
Inertia .
When an Error Occurs during Calculation of Moment of
Travel distance setting error
The travel distance is set to approximately
0.5 rotation or less, which is less than the minimum adjustable travel distance.
The positioning completed signal (/COIN) did not turn ON within approximately 10 seconds after positioning adjustment was completed.
The moment of inertia cannot be calculated when the tuning-less function was activated.
The positioning completed width is too narrow or proportional control (P control) is being used.
When the tuning-less function was activated, Jcalc was set to OFF so the moment of inertia was not calculated.
Increase the travel distance. It is recommended to set the number of motor rotations to around 3.
• Increase the set value for Pn522.
• Set 0 to V_PPI in the OPTION field.
• Turn OFF the tuning-less function.
• Set Jcalc to ON , so the moment of inertia will be calculated.
When an Error Occurs during Calculation of Moment of Inertia
The following table shows the probable causes of errors that may occur during the calculation of the moment of inertia with the Jcalc set to ON, along with corrective actions for the errors.
Error
Display
Err1
Err2
Err3
Err4
Err5
Probable Cause Corrective Actions
The SERVOPACK started calculating the moment of inertia, but the calculation was not completed.
• Increase the speed loop gain (Pn100).
• Increase the STROKE (travel distance).
The moment of inertia fluctuated greatly and did not converge within 10 tries.
Low-frequency vibration was detected.
The torque limit was reached.
Set the calculation value based on the machine specifications in Pn103 and execute the calculation with the
Jcalc set to OFF.
Double the set value of the moment of inertia calculating start level (Pn324).
• When using the torque limit, increase the torque limit.
• Double the set value of the moment of inertia calculating start level (Pn324).
While calculating the moment of inertia, the speed control was set to proportional control by setting 1 to V_PPI in the OPTION field.
Operate the SERVOPACK with PI control while calculating the moment of inertia.
5.3 Advanced Autotuning (Fn201)
(3) Related Functions on Advanced Autotuning
This section describes functions related to advanced tuning.
Notch Filter
Usually, set this function to Auto Setting. (The notch filter is factory-set to Auto Setting.)
If this function is set to Auto Setting, vibration will be detected automatically during advanced autotuning and the notch filter will be set.
Set this function to Not Auto Setting only if you do not change the notch filter setting before executing advanced autotuning.
Pn460
Parameter n.
0 n.
1
[Factory setting] n. 0 n. 1
[Factory setting]
Function
Does not set the 1st notch filter automatically with the utility function.
Sets the 1st notch filter automatically with the utility function.
Does not set the 2nd notch filter automatically with the utility function.
Sets the 2nd notch filter automatically with the utility function.
When Enabled Classification
Immediately Tuning
Anti-Resonance Control Adjustment
This function reduces low vibration frequency, which the notch filter does not detect.
Usually, set this function to Auto Setting. (The anti-resonance control is factory-set to Auto Setting.)
When this function is set to Auto Setting, vibration will be automatically detected during advanced autotuning and anti-resonance control will be automatically adjusted and set.
Pn160
Parameter n.
0 n.
1
[Factory setting]
Function
Does not use the anti-resonance control automatically with the utility function.
Uses the anti-resonance control automatically with the utility function.
When Enabled Classification
Immediately Tuning
Vibration Suppression
The vibration suppression function suppresses transitional vibration at frequency as low as 1 to 100 Hz that is generated mainly when positioning if the machine stand vibrates.
Usually, set this function to Auto Setting. (The vibration suppression function is factory-set to Auto Setting.)
When this function is set to Auto Setting, vibration will be automatically detected during advanced autotuning and vibration suppression will be automatically adjusted and set.
Set this function to Not Auto Setting only if you do not change the setting for vibration suppression before executing advanced autotuning.
Note: This function uses model following control. Therefore, the function can be executed only if the mode is set to 2 or 3.
• Related Parameter
Pn140
Parameter n. 0 n. 1
[Factory setting]
Function
Does not use the vibration suppression function automatically with the utility function.
Uses the vibration suppression function automatically with the utility function.
When Enabled Classification
Immediately Tuning
5
5-25
5-26
5 Adjustments
5.3.2 Advanced Autotuning Procedure
Friction Compensation
This function compensates for changes in the following conditions.
• Changes in the viscous resistance of the lubricant, such as the grease, on the sliding parts of the machine
• Changes in the friction resistance resulting from variations in the machine assembly
• Changes in the friction resistance due to aging
The conditions for applying friction compensation depend on the mode. The friction compensation setting in
Pn408.3 applies when the Mode is 1. The friction compensation function is always enabled regardless of the friction compensation setting in Pn408.3 when the Mode is 2 or 3.
Friction
Compensation
Selecting
Pn408 n.0
[Factory setting]
Mode n.1
Mode = 1 Mode = 2
Adjusted without the friction compensation function
Adjusted with the friction compensation function
Adjusted with the friction compensation function
Mode = 3
Adjusted with the friction compensation function
Feedforward
If Pn140 is set to the factory setting and the mode setting is changed to 2 or 3, the feedforward gain (Pn109), speed feedforward (VFF) input, and torque feedforward (TFF) input will be disabled.
Set Pn140.3 to 1 if model following control is used together with the speed feedforward (VFF) input and torque feedforward (TFF) input from the host controller.
Pn140
Parameter n.0
[Factory setting] n.1
Function
Model following control is not used together with the speed/torque feedforward input.
Model following control is used together with the speed/torque feedforward input.
When Enabled Classification
Immediately Tuning
Refer to Σ -V Series User’s Manual MECHATROLINK-II Commands (No.: SIEP S800000 54) for details.
• Model following control is used to make optimum feedforward settings in the SERVO-
PACK when model following control is used with the feedforward function. Therefore, model following control is not normally used together with either the speed feedforward (VFF) input or torque feedforward (TFF) input from the host controller. However, model following control can be used with the speed feedforward (VFF) input or torque feedforward (TFF) input if required. An improper feedforward input may result in overshooting.
5.3 Advanced Autotuning (Fn201)
5.3.3
Related Parameters
The following table lists parameters related to this function and their possibility of being changed while executing this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes : Parameters can be changed using SigmaWin+ while this function is being executed.
No : Parameters cannot be changed using SigmaWin+ while this function is being executed.
• Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
Parameter
Pn161
Pn163
Pn531
Pn533
Pn534
Pn535
Pn536
Pn141
Pn142
Pn143
Pn144
Pn145
Pn146
Pn147
Pn160
Pn125
Pn401
Pn408
Pn409
Pn40A
Pn40C
Pn40D
Pn140
Pn100
Pn101
Pn102
Pn103
Pn121
Pn123
Pn124
Name
Speed Loop Gain
Speed Loop Integral Time Constant
Position Loop Gain
Moment of Inertia Ratio
Friction Compensation Gain
Friction Compensation Coefficient
Friction Compensation Frequency Correction
Friction Compensation Gain Correction
Torque Reference Filter Time Constant
Torque Related Function Switch
1st Notch Filter Frequency
1st Notch Filter Q Value
2nd Notch Filter Frequency
2nd Notch Filter Q Value
Model Following Control Related Switch
Model Following Control Gain
Model Following Control Gain Compensation
Model Following Control Bias (Forward Direction)
Model Following Control Bias (Reverse Direction)
Vibration Suppression 1 Frequency A
Vibration Suppression 1 Frequency B
Model Following Control Speed Feedforward Compensation
Anti-Resonance Control Related Switch
Anti-Resonance Frequency
Anti-Resonance Damping Gain
Program JOG Movement Distance
Program JOG Movement Speed
Program JOG Acceleration/Deceleration Time
Program JOG Waiting Time
Number of Times of Program JOG Movement
No
No
No
No
No
No
Yes
No
No
No
No
No
No
No
Yes
No
No
Mid-execution changes
No
No
No
No
No
Yes
No
No
No
No
No
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Automatic changes
Yes
Yes
Yes
No
Yes
5
5-27
5-28
5 Adjustments
5.4.1 Advanced Autotuning by Reference
5.4
Advanced Autotuning by Reference (Fn202)
Adjustments with advanced autotuning by reference are described below.
• Advanced autotuning by reference starts adjustments based on the set speed loop gain (Pn100). Therefore, precise adjustments cannot be made if there is vibration when starting adjustments. In this case, make adjustments after lowering the speed loop gain (Pn100) until vibration is eliminated.
5.4.1
Advanced Autotuning by Reference
Advanced autotuning by reference is used to automatically achieve optimum tuning of the SERVOPACK in response to the user reference inputs from the host controller.
Advanced autotuning by reference is performed generally to fine-tune the SERVOPACK after advanced autotuning of the SERVOPACK has been performed.
If the moment of inertia ratio is correctly set to Pn103, advanced autotuning by reference can be performed without performing advanced autotuning.
Movement speed
Reference
M-II
Reference
Response
Travel distance
Host controller
SERVOPACK
Advanced autotuning by reference performs the following adjustments.
• Gains (e.g., position loop gain and speed loop gain)
• Filters (torque reference filter and notch filter)
• Friction compensation
• Anti-resonance control
• Vibration suppression
Refer to 5.4.3 Related Parameters for parameters used for adjustments.
CAUTION
• Because advanced autotuning by reference adjusts the SERVOPACK during automatic operation, vibration or overshooting may occur. To ensure safety, perform advanced autotuning by reference in a state where the SERVOPACK can come to an emergency stop at any time.
5.4 Advanced Autotuning by Reference (Fn202)
(1) Preparation
Check the following settings before performing advanced autotuning by reference. The message “NO-OP” indicating that the settings are not appropriate will be displayed, if all of the following conditions are not met.
• The SERVOPACK must be in Servo Ready status (Refer to 4.8.4
).
• There must be no overtravel.
• The servomotor power must be OFF.
• The position control must be selected when the servomotor power is ON.
• The gain selection switch must be in manual switching mode (Pn139.0 = 0).
• Gain setting 1 must be selected.
• The test without a motor function must be disabled. (Pn00C.0 = 0).
• All warnings must be cleared.
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
• The tuning-less function must be disabled (Pn170.0 = 0).
(2) When Advanced Autotuning by Reference Cannot Be Performed Successfully
Advanced autotuning by reference cannot be performed successfully under the following conditions. If the result of autotuning is not satisfactory, perform one-parameter tuning (Fn203). Refer to 5.5 One-parameter
Tuning (Fn203) for details.
• The travel distance in response to references from the host controller is smaller than the set positioning completed width (Pn522).
• The motor speed in response to references from the host controller is smaller than the set rotation detection level (Pn502).
• The stopping time, i.e., the period while the positioning completed /COIN signal is OFF, is 10 ms or less.
• The rigidity of the machine is low and vibration occurs when positioning is performed.
• The position integration function is used.
• P control operation (proportional control) is performed.
• The mode switch is used.
• The positioning completed width (Pn522) is too small.
• Advanced autotuning by reference starts adjustments based on the positioning completed width (Pn522). Set the electronic gear ratio (Pn20E/Pn210) and positioning completed width (Pn522) to the actual value during operation.
• Unless the positioning completed signal (/COIN) is turned ON within approximately 3 seconds after positioning has been completed, "WAITING" will flash. Furthermore, unless the positioning completed signal (/COIN) is turned ON within approximately 10 seconds, "Error" will flash for 2 seconds and tuning will be aborted.
Change only the overshoot detection level (Pn561) to finely adjust the amount of overshooting without changing the positioning completed width (Pn522). Because Pn561 is set by default to 100%, the allowable amount of overshooting is the same amount as that for the positioning completed width.
When Pn561 is set to 0%, the amount of overshooting can be adjusted without any overshooting in the positioning completed width. If the setting of Pn561 is changed, however, the positioning time may be extended.
Pn561
Overshoot Detection Level
Setting Range
0 to 100
Setting Unit
1%
Speed Position Torque
Factory Setting
100
When Enabled
Immediately
Classification
Setup
5
5-29
5-30
5 Adjustments
5.4.2 Advanced Autotuning by Reference Procedure
5.4.2
Advanced Autotuning by Reference Procedure
The following procedure is used for advanced autotuning by reference.
Advanced autotuning by reference is performed from the digital operator (option) or SigmaWin+.
Here, the operating procedure from the digital operator is described.
Refer to the Σ -V Series User’s Manual, Operation of Digital Operator operations of the digital operator.
(No.: SIEP S800000 55) for basic key
CAUTION
• When using the MP2000 Series with phase control, select the mode = 1 (standard level). If 2 or 3 is selected, phase control of the MP2000 Series may not be possible.
(1) Operating Procedure
Set the correct moment of inertia ratio in Pn103 by using the advanced autotuning before performing this procedure.
Step
1
2
Display after Operation
㧮㧮 ޓ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧝㧦㧭㧭㨀
㧲㨚㧞㧜㧞㧦㧾㨑㨒㧭㧭㨀
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
㧲㨚㧞㧜㧠㧦㧭㨂㨕㨎ޓ㧿㨡㨜
Status Display
㧮㧮 㧭㨐㨢㨍㨚㨏㨑㨐 㧭㨀
ޓ㧹 㨛 㨐 㨑㧩㧟ޓ㨀㨥㨜㨑㧩㧞
Keys Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn202.
Key to move through the list and
Press the Key to display the initial setting screen for Fn202(Advanced Autotuning by Reference).
3
㧮㧮 㧭㨐㨢㨍㨚㨏㨑㨐 㧭㨀
ޓ㧹 㨛 㨐 㨑㧩㧟ޓ㨀㨥㨜㨑㧩㧞
Press the , steps 3-1 and 3-2.
, or Key and set the items in
3-1
3-2
4
5
Mode Selection
Select the mode.
Mode = 1: Makes adjustments considering response characteristics and stability (Standard level).
Mode = 2: Makes adjustments for positioning [Factory setting].
Mode = 3: Makes adjustments for positioning, giving priority to overshooting suppression.
Type Selection
Select the type according to the machine element to be driven.
If there is noise or the gain does not increase, better results may be obtained by changing the rigidity type.
Type = 1: For belt drive mechanisms
Type = 2: For ball screw drive mechanisms [Factory setting]
Type = 3: For rigid systems in which the servomotor is directly coupled to the machine (without gear or other
transmissions)
㧮㧮 㧭㨐㨢㨍㨚㨏㨑㨐 㧭㨀
㧼㨚㧝㧜㧟㧩㧜㧜㧟㧜㧜
㧼㨚㧝㧜㧜㧩㧜㧜㧠㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧞㧜㧜㧜
㧼㨚㧝㧠㧝㧩㧜㧜㧡㧜㧜
Press the Key. The advanced autotuning by reference execution screen will be displayed.
Note: If the mode is set to 1, Pn102 is displayed. If the mode is set to 2 or 3, the Pn102 display will change to the Pn141.
㧾㨁㧺 㧭㨐㨢㨍㨚㨏㨑㨐 㧭㨀
㧼㨚㧝㧜㧟㧩㧜㧜㧟㧜㧜
㧼㨚㧝㧜㧜㧩㧜㧜㧠㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧞㧜㧜㧜
㧼㨚㧝㧠㧝㧩㧜㧜㧡㧜㧜
– Send an SV_ON command from the host controller.
5.4 Advanced Autotuning by Reference (Fn202)
Step
6
Display after Operation
㧭㧰㧶 㧭㨐㨢㨍㨚㨏㨑㨐 㧭㨀
㧼㨚㧝㧜㧟㧩㧜㧜㧟㧜㧜
㧼㨚㧝㧜㧜㧩㧜㧝㧜㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧜㧢㧟㧢
㧼㨚㧝㧠㧝㧩㧜㧝㧡㧜㧜
Keys
(cont’d)
Operation
Input a reference from the host controller and then press the or Key to start the adjustment.
"ADJ" will flash during adjustment on the status display.
Note: Adjustment cannot be performed during "BB" is shown on the status display.
7
㧭㧰㧶 㧭㨐㨢㨍㨚㨏㨑㨐 㧭㨀
㧼㨚㧝㧜㧟㧩㧜㧜㧟㧜㧜
㧼㨚㧝㧜㧜㧩㧜㧝㧜㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧜㧢㧟㧢
㧼㨚㧝㧠㧝㧩㧜㧝㧡㧜㧜
–
When the adjustment has been completed normally,
"END" will flash for approximately two seconds and
"ADJ" will be displayed.
8
㧾㨁㧺 㧭㨐㨢㨍㨚㨏㨑㨐 㧭㨀
㧼㨚㧝㧜㧟㧩㧜㧜㧟㧜㧜
㧼㨚㧝㧜㧜㧩㧜㧝㧜㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧜㧢㧟㧢
㧼㨚㧝㧠㧝㧩㧜㧝㧡㧜㧜
Press the Key to save the settings. "DONE" will flash for approximately two seconds and "RUN" will be displayed.
Note: Not to save the values set in step 6, press the
Key. The display will return to that shown in step 1.
9 Turn ON the SERVOPACK power supply again after executing advanced autotuning by reference.
(2) Failure in Operation
When "NO-OP" Flashes on the Display
Probable Cause
The main circuit power supply was OFF.
An alarm or warning occurred.
Overtraveling occurred.
Gain setting 2 was selected by gain switching.
HWBB operated.
When "Error" Flashes on the Display
Corrective Actions
Turn ON the main circuit power supply.
Remove the cause of the alarm or the warning.
Remove the cause of the overtravel.
Disable the automatic gain switching.
Disable the HWBB function.
Error
The gain adjustment was not successfully completed.
Probable Cause
Machine vibration is occurring or the positioning completed signal (/COIN) is turning
ON and OFF when the servomotor is stopped.
Corrective Actions
• Increase the set value for Pn522.
• Change the mode from 2 to 3.
• If machine vibration occurs, suppress the vibration with the anti-resonance control adjustment function and the vibration suppression function.
The positioning completed signal
(/COIN) did not turn ON within approximately 10 seconds after positioning adjustment was completed.
The positioning completed width is too narrow or proportional control (P control) is being used.
• Increase the set value for Pn522.
• Set 0 to V_PPI of OPTION field.
5
5-31
5-32
5 Adjustments
5.4.2 Advanced Autotuning by Reference Procedure
(3) Related Functions on Advanced Autotuning by Reference
This section describes functions related to advanced autotuning by reference.
Notch Filter
Usually, set this function to Auto Setting. (The notch filter is factory-set to Auto Setting.)
If this function is set to Auto Setting, vibration will be detected automatically during advanced autotuning by reference, and the notch filter will be set.
Set this function to Not Auto Setting only if you do not change the notch filter setting before executing advanced autotuning by reference.
Pn460
Parameter n.
n. 0
0 n.
1
[Factory setting] n. 1
[Factory setting]
Function
Does not set the 1st notch filter automatically with the utility function.
Sets the 1st notch filter automatically with the utility function.
Does not set the 2nd notch filter automatically with the utility function.
Sets the 2nd notch filter automatically with the utility function.
When Enabled Classification
Immediately Tuning
Anti-Resonance Control Adjustment
This function reduces low vibration frequency, which the notch filter does not detect.
Usually, set this function to Auto Setting. (The anti-resonance control is factory-set to Auto Setting.)
When this function is set to Auto Setting, vibration will be automatically detected during advanced autotuning by reference and anti-resonance control will be automatically adjusted and set.
Pn160
Parameter n.
0 n.
1
[Factory setting]
Function
Does not use the anti-resonance control automatically with the utility function.
Uses the anti-resonance control automatically with the utility function.
When Enabled Classification
Immediately Tuning
Vibration Suppression
The vibration suppression function suppresses transitional vibration at frequency as low as 1 to 100 Hz that is generated mainly when positioning if the machine stand vibrates.
Usually, set this function to Auto Setting. (The vibration suppression function is factory-set to Auto Setting.)
When this function is set to Auto Setting, vibration will be automatically detected during advanced autotuning by reference and vibration suppression will be automatically adjusted and set.
Set this function to Not Auto Setting only if you do not change the setting for vibration suppression before executing advanced autotuning by reference.
Note: This function uses model following control. Therefore, the function can be executed only if the mode is set to 2 or 3.
• Related Parameters
Pn140
Parameter n. 0 n. 1
[Factory setting]
Function
Does not use the vibration suppression function automatically.
Uses the vibration suppression function automatically.
When Enabled Classification
Immediately Tuning
5.4 Advanced Autotuning by Reference (Fn202)
Friction Compensation
This function compensates for changes in the following conditions.
• Changes in the viscous resistance of the lubricant, such as the grease, on the sliding parts of the machine
• Changes in the friction resistance resulting from variations in the machine assembly
• Changes in the friction resistance due to aging
Conditions to which friction compensation is applicable depend on the mode. The friction compensation setting in Pn408.3 applies when the mode is 1. Mode = 2 and Mode = 3 are adjusted with the friction compensation function regardless of the friction compensation setting in P408.3.
Friction
Compensation
Selecting
Pn408 n.0
[Factory setting]
Mode n.1
Mode = 1 Mode = 2
Adjusted without the friction compensation function
Adjusted with the friction compensation function
Adjusted with the friction compensation function
Mode = 3
Adjusted with the friction compensation function
Feedforward
If Pn140 is set to the factory setting and the mode setting is changed to 2 or 3, the feedforward gain (Pn109), speed feedforward (VFF) input, and torque feedforward (TFF) input will be disabled.
Set Pn140.3 to 1 if model following control is used together with the speed feedforward (VFF) input and torque feedforward (TFF) input from the host controller.
Pn140
Parameter n.0
[Factory setting] n.1
Function
Model following control is not used together with the speed/torque feedforward input.
Model following control is used together with the speed/torque feedforward input.
When Enabled Classification
Immediately Tuning
Refer to Σ -V Series User’s Manual MECHATROLINK-II Commands (No.: SIEP S800000 54) for details.
• Model following control is used to make optimum feedforward settings in the SERVO-
PACK when model following control is used with the feedforward function. Therefore, model following control is not normally used together with either the speed feedforward (VFF) input or torque feedforward (TFF) input from the host controller. However, model following control can be used with the speed feedforward (VFF) input or torque feedforward (TFF) input if required. An improper feedforward input may result in overshooting.
5
5-33
5-34
5 Adjustments
5.4.3 Related Parameters
5.4.3
Related Parameters
The following table lists parameters related to this function and their possibility of being changed while executing this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes : Parameters can be changed using SigmaWin+ while this function is being executed.
No : Parameters cannot be changed using SigmaWin+ while this function is being executed.
• Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
Parameter
Pn125
Pn401
Pn408
Pn409
Pn40A
Pn40C
Pn40D
Pn140
Pn100
Pn101
Pn102
Pn103
Pn121
Pn123
Pn124
Pn141
Pn142
Pn143
Pn144
Pn145
Pn146
Pn147
Pn160
Pn161
Pn163
Name
Speed Loop Gain
Speed Loop Integral Time Constant
Position Loop Gain
Moment of Inertia Ratio
Friction Compensation Gain
Friction Compensation Coefficient
Friction Compensation Frequency Correction
Friction Compensation Gain Correction
Torque Reference Filter Time Constant
Torque Related Function Switch
1st Notch Filter Frequency
1st Notch Filter Q Value
2nd Notch Filter Frequency
2nd Notch Filter Q Value
Model Following Control Related Switch
Model Following Control Gain
Model Following Control Gain Compensation
Model Following Control Bias (Forward Direction)
Model Following Control Bias (Reverse Direction)
Vibration Suppression 1 Frequency A
Vibration Suppression 1 Frequency B
Model Following Control Speed Feedforward Compensation
Anti-Resonance Control Related Switch
Anti-Resonance Frequency
Anti-Resonance Damping Gain
No
No
No
No
No
Yes
No
No
No
Yes
No
No
Mid-execution changes
No
No
No
No
No
Yes
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Automatic changes
Yes
Yes
Yes
No
Yes
5.5 One-parameter Tuning (Fn203)
5.5
One-parameter Tuning (Fn203)
Adjustments with one-parameter tuning are described below.
5.5.1
One-parameter Tuning
One-parameter tuning is used to manually make tuning level adjustments during operation with a position reference or speed reference input from the host controller.
One-parameter tuning enables automatically setting related servo gain settings to balanced conditions by adjusting one or two tuning levels.
One-parameter tuning performs the following adjustments.
• Gains (e.g., position loop gain and speed loop gain)
• Filters (torque reference filter and notch filter)
• Friction compensation
• Anti-resonance control
Refer to 5.5.4 Related Parameters for parameters used for adjustments.
Perform one-parameter tuning if satisfactory response characteristics is not obtained with advanced autotuning or advanced autotuning by reference.
To fine-tune each servo gain after one-parameter tuning, refer to 5.8 Additional Adjustment Function .
CAUTION
• Vibration or overshooting may occur during adjustment. To ensure safety, perform one-parameter tuning in a state where the SERVOPACK can come to an emergency stop at any time.
Preparation
Check the following settings before performing one-parameter tuning.
The message “NO-OP” indicating that the settings are not appropriate will be displayed, if all of the following conditions are not met.
• The test without a motor function must be disabled (Pn00C.0 = 0).
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
• The tuning-less function must be disabled (Pn170.0 = 0).
• The tuning mode must be set to 0 or 1 when performing speed control.
• The main circuit power must be ON.
• All alarms must be cleared.
• The hardwire baseblock (HWBB) must be disabled.
5
5-35
5-36
5 Adjustments
5.5.2 One-parameter Tuning Procedure
5.5.2
One-parameter Tuning Procedure
The following procedure is used for one-parameter tuning.
There are the following two operation procedures depending on the tuning mode being used.
• When the tuning mode is set to 0 or 1, the model following control will be disabled and one-parameter tuning will be used as the tuning method for applications other than positioning.
• When the tuning mode is set to 2 or 3, the model following control will be enabled and it can be used for tuning for positioning.
One-parameter tuning is performed from the digital operator (option) or SigmaWin+.
Make sure that the moment of inertia ratio (Pn103) is set correctly using advance autotuning before beginning operation.
The following section provides the operating procedure from the digital operator.
Refer to the Σ -V Series User’s Manual, Operation of Digital Operator operations of the digital operator.
(No.: SIEP S800000 55) for basic key
CAUTION
• When using the MP2000 Series with phase control, select the tuning mode = 0 or 1. If 2 or 3 is selected, phase control of the MP2000 Series may not be possible.
(1) Digital Operator Operating Procedure
Setting the Tuning Mode 0 or 1
Step
1
Display after Operation
㧮㧮ޓ ޓ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧞㧦㧾㨑㨒㧭㧭㨀
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
㧲㨚㧞㧜㧠㧦㧭㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧡㧦㨂㨕㨎ޓ㧿㨡㨜
2
Status Display
㧮 㧮 ̆ 㧻 㨚 㨑 㧼 㨞 㨙 㨀 㨡 㨚̆
㧼 㨚 㧝 㧜 㧟 㧩 㧜 㧜 㧟 㧜 㧜
Keys Operation
Press the Key to view the main menu for the utility function.
Press the or and select Fn203.
Key to move through the list
Press the Key to display the moment of inertia ratio set in Pn103 at present. Move the digit with the
or Key and change the value with the
3
㧮 㧮 ̆ 㧻 㨚 㨑 㧼 㨞 㨙 㨀 㨡 㨚̆
㧿 㨑 㨠 㨠 㨕 㨚 㨓
㨀 㨡 㨚 㨕 㨚 㨓 㧹 㨛 㨐 㨑 㧩 㧜
㨀 㨥 㨜 㨑 㧩 㧞
Press the Key to display the initial setting screen for one-parameter tuning.
4
4-1
㧮 㧮 ̆ 㧻 㨚 㨑 㧼 㨞 㨙 㨀 㨡 㨚̆
㧿 㨑 㨠 㨠 㨕 㨚 㨓
㨀 㨡 㨚 㨕 㨚 㨓 㧹 㨛 㨐 㨑 㧩 㧜
㨀 㨥 㨜 㨑 㧩 㧞
Press the , steps 4-1 and 4-2.
Tuning Mode
Select the tuning mode. Select the tuning mode 0 or 1.
Tuning Mode = 0: Makes adjustments giving priority to stability.
Tuning Mode = 1: Makes adjustments giving priority to responsiveness.
, or Key and set the items in
5.5 One-parameter Tuning (Fn203)
Step
4-2
(cont’d)
Display after Operation Keys Operation
Type Selection
Select the type according to the machine element to be driven.
If there is noise or the gain does not increase, better results may be obtained by changing the rigidity type.
Type = 1: For belt drive mechanisms
Type = 2: For ball screw drive mechanisms [Factory setting]
Type = 3: For rigid systems in which the servomotor is directly coupled to the machine (without gear or other
transmissions).
5
㧾㨁㧺 ̆ 㧻 㨚 㨑 㧼 㨞 㨙 㨀 㨡 㨚̆
㧿㨑㨠㨠㨕㨚 㨓
㨀 㨡 㨚 㨕 㨚 㨓 㧹 㨛 㨐 㨑 㧩 㧜
㨀 㨥 㨜 㨑 㧩 㧞
–
If the servomotor power is OFF, send an SV_ON command from the host controller. The display will change from "BB" to "RUN."
If the servomotor power is ON, go to step 6.
6
㧾㨁㧺 ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧼㨚㧝㧜㧜㧩㧜㧜㧠㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧞㧜㧜㧜
㧼㨚㧝㧜㧞㧩㧜㧜㧠㧜㧜
Press the Key to display the set value.
7
8
㧾㨁㧺 ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧸㧱㨂㧱㧸 㧩 㧜㧜㧡㧜
ޓ㧺㧲㧝ޓ㧺㧲㧞
㧭㧾㧱㧿
㧾㨁㧺 ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧸㧱㨂㧱㧸 㧩 㧜㧜㧡㧜
ޓ㧺㧲㧝ޓ㧺㧲㧞
㧭㧾㧱㧿
Press the Key again to display the LEVEL setting screen.
If readjustment is required, select the digit with the
or Key or change the LEVEL with the or Key. Check the response.
If readjustment is not required, go to step 9.
Note: The higher the level, the greater the responsiveness will be. If the value is too large, however, vibration will occur.
• If vibration occurs, press the Key. The SER-
VOPACK will automatically detect the vibration frequencies and make notch filter or an anti-resonance control settings. When the notch filter is set,
"NF1" or "NF2" will be displayed on the bottom row. When the anti-resonance control is set,
"ARES" will be displayed in the lower right corner.
㧾㨁㧺 ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
ޓޓޓ㧸㧱㨂㧱㧸㧩㧜㧜㧣㧜
• If the vibration is great, the vibration frequency will be detected automatically even if the Key is not pressed and a notch filter or an anti-resonance control will be set.
Note: The status display will always be RUN when the servomotor power is ON.
5
5-37
5-38
5 Adjustments
5.5.2 One-parameter Tuning Procedure
Step
9
Display after Operation
㧾㨁㧺 ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧼㨚㧝㧜㧜㧩㧜㧜㧡㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧝㧢㧜
㧼㨚㧝㧜㧞㧩㧜㧜㧡㧜㧜
10
㧾㨁㧺 ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧼㨚㧝㧜㧜㧩㧜㧜㧡㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧝㧢㧜
㧼㨚㧝㧜㧞㧩㧜㧜㧡㧜㧜
11
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧞㧦㧾㨑㨒㧭㧭㨀
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
㧲㨚㧞㧜㧠㧦㧭㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧡㧦㨂㨕㨎ޓ㧿㨡㨜
Keys
(cont’d)
Operation
Press the Key. A confirmation screen will be displayed after LEVEL adjustment.
• Press the Key to save the adjusted values.
After the data is saved, “DONE” will flash for approximately two seconds and then “RUN” will be displayed.
• To return to the previous value, press the Key.
• Press the Key to readjust the level without saving the values.
Press the Key to complete the one-parameter tuning operation. The screen in step 1 will appear again.
5.5 One-parameter Tuning (Fn203)
Setting the Tuning Mode 2 or 3
Step
1
Display after Operation
㧮㧮ޓ ޓ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧞㧦㧾㨑㨒㧭㧭㨀
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
㧲㨚㧞㧜㧠㧦㧭㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧡㧦㨂㨕㨎ޓ㧿㨡㨜
2
Status Display
㧮 㧮 ̆ 㧻 㨚 㨑 㧼 㨞 㨙 㨀 㨡 㨚̆
㧼 㨚 㧝 㧜 㧟 㧩 㧜 㧜 㧟 㧜 㧜
Keys Operation
Press the Key to view the main menu for the utility function.
Press the or and select Fn203.
Key to move through the list
Press the Key to display the moment of inertia ratio set in Pn103 at present. Move the digit with the
or Key and change the value with the
3
㧮 㧮 ̆ 㧻 㨚 㨑 㧼 㨞 㨙 㨀 㨡 㨚̆
㧿 㨑 㨠 㨠 㨕 㨚 㨓
㨀 㨡 㨚 㨕 㨚 㨓 㧹 㨛 㨐 㨑 㧩 㧞
㨀 㨥 㨜 㨑 㧩 㧞
Press the Key to display the initial setting screen for one-parameter tuning.
4
4-1
4-2
5
㧮 㧮 ̆ 㧻 㨚 㨑 㧼 㨞 㨙 㨀 㨡 㨚̆
㧿 㨑 㨠 㨠 㨕 㨚 㨓
㨀 㨡 㨚 㨕 㨚 㨓 㧹 㨛 㨐 㨑 㧩 㧞
㨀 㨥 㨜 㨑 㧩 㧞
Press the , steps 4-1 and 4-2.
, or Key and set the items in
Tuning Mode
Select the tuning mode. Select the tuning mode 2 or 3.
Tuning Mode = 2: Enables model following control and makes adjustments for positioning.
Tuning Mode = 3: Enables model following control, makes adjustments for positioning, and suppresses overshooting.
Type Selection
Select the type according to the machine element to be driven.
If there is noise or the gain does not increase, better results may be obtained by changing the rigidity type.
Type = 1: For belt drive mechanisms
Type = 2: For ball screw drive mechanisms [Factory setting]
Type = 3: For rigid systems in which the servomotor is directly coupled to the machine (without gear or other
transmissions).
㧾㨁㧺 ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
ޓ㧿㨑㨠㨠㨕㨚㨓
㨀㨡㨚㨕㨚㨓ޓ㧹㨛㨐㨑㧩㧞
ޓޓޓޓޓޓޓ㨀㨥㨜㨑㧩㧞
–
If the servomotor power is OFF, send an SV_ON command from the host controller. The display will change from "BB" to "RUN."
If the servomotor power is ON, go to step 6.
6
㧾㨁㧺 ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧼㨚㧝㧜㧜㧩㧜㧜㧠㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧞㧜㧜㧜
㧼㨚㧝㧠㧝㧩㧜㧜㧡㧜㧜
Press the Key to display the set value.
7
㧾㨁㧺ޓ ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧲㧲ޓ㧸㧱㨂㧱㧸㧩㧜㧜㧡㧜㧚㧜
㧲㧮ޓ㧸㧱㨂㧱㧸㧩㧜㧜㧠㧜㧚㧜
Press the Key again to display FF LEVEL and
FB LEVEL setting screens.
5
5-39
5-40
5 Adjustments
5.5.2 One-parameter Tuning Procedure
Step
8
9
10
11
Display after Operation
㧾㨁㧺ޓ ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧲㧲ޓ㧸㧱㨂㧱㧸㧩㧜㧜㧡㧜㧚㧜
㧲㧮ޓ㧸㧱㨂㧱㧸㧩㧜㧜㧠㧜㧚㧜
Keys
(cont’d)
Operation
If readjustment is required, select the digit with the
or Key or change the FF LEVEL and FB
LEVEL with the or Key. Check the response.
If readjustment is not required, go to step 9.
Note: The higher the FF LEVEL, the positioning time will be shorter and the response will be better.
If the level is too high, however, overshooting or vibration may occur. Overshooting will be reduced if the FB LEVEL is increased.
If Vibration Occurs
• If vibration occurs, press the Key. The SER-
VOPACK will automatically detect the vibration frequencies and make notch filter or an anti-resonance control settings. When the notch filter is set,
“NF1” and “NF2” are displayed on the bottom row.
When the anti-resonance control is set, “ARES” will be displayed on the bottom low.
㧾㨁㧺ޓ ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧲㧲ޓ㧸㧱㨂㧱㧸㧩㧜㧜㧡㧜㧚㧜
㧲㧮ޓ㧸㧱㨂㧱㧸㧩㧜㧜㧠㧜㧚㧜
ޓ㧺㧲㧝ޓޓ㧺㧲㧞ޓޓ㧭㧾㧱㧿
If Vibration Is Large
• Even if the Key is not pressed, the SERVO-
PACK will automatically detect the vibration frequencies and make notch filter or anti-resonance control settings.
Notes:
• If the FF LEVEL is changed when the servomotor is in operation, it will not be reflected immediately.
The changes will be effective after the servomotor comes to a stop with no reference input and then the servomotor starts operation If the FF LEVEL is changed too much during operation, vibration may occur because the responsiveness is changed rapidly when the settings become effective.
• The message “FF LEVEL” flashes until the machine reaches the effective FF LEVEL. If the servomotor does not stop within approximately 10 seconds after changing the setting, a timeout will occur. The setting will be returned to the previous value.
㧾㨁㧺 ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧼㨚㧝㧜㧜㧩㧜㧜㧠㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧞㧜㧜㧜
㧼㨚㧝㧠㧝㧩㧜㧜㧡㧜㧜
㧺㧲㧝
Press the Key to display the confirmation screen after level adjustment.
㧾㨁㧺 ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧼㨚㧝㧜㧜㧩㧜㧜㧠㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧞㧜㧜㧜
㧼㨚㧝㧠㧝㧩㧜㧜㧡㧜㧜
㧺㧲㧝
• Press the Key to save the adjusted values.
After the data is saved, “DONE” will flash for approximately two seconds and then “RUN” will be displayed.
• To return to the previous value, press the Key.
• Press the Key to readjust the level without saving the values.
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧞㧦㧾㨑㨒㧭㧭㨀
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
㧲㨚㧞㧜㧠㧦㧭㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧡㧦㨂㨕㨎ޓ㧿㨡㨜
Press the Key to complete the one-parameter tuning operation. The screen in step 1 will appear again.
Note: The status display will always be RUN when the servomotor power is ON.
5.5 One-parameter Tuning (Fn203)
(2) Related Functions on One-parameter Tuning
This section describes functions related to one-parameter tuning.
Notch Filter
Usually, set this function to Auto Setting. (The notch filter is factory-set to Auto Setting.)
If this function is set to Auto Setting, vibration will be detected automatically during one-parameter tuning and the notch filter will be set.
Set this function to Not Auto Setting only if you do not change the notch filter setting before executing oneparameter tuning.
Pn460
Parameter n.
n. 0
0 n.
1
[Factory setting] n. 1
[Factory setting]
Function
Does not set the 1st notch filter automatically with the utility function.
Sets the 1st notch filter automatically with the utility function.
Does not set the 2nd notch filter automatically with the utility function.
Sets the 2nd notch filter automatically with the utility function.
When Enabled Classification
Immediately Tuning
Anti-Resonance Control Adjustment
This function reduces low vibration frequency, which the notch filter does not detect.
Usually, set this function to Auto Setting. (The anti-resonance control is factory-set to Auto Setting.)
When this function is set to Auto Setting, vibration will be automatically detected during one-parameter tuning and anti-resonance control will be automatically adjusted and set.
When Enabled Classification
Pn160
Parameter n.
0 n.
1
[Factory setting]
Function
Does not use the anti-resonance control automatically with the utility function.
Uses the anti-resonance control automatically with the utility function.
Immediately Tuning
"ARES" will flash on the digital operator when anti-resonance control adjustment function is set.
㧾㨁㧺 ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧲㧲ޓ㧸㧱㨂㧱㧸ޓ㧩ޓ㧜㧜㧡㧜
㧲㧮ޓ㧸㧱㨂㧱㧸ޓ㧩ޓ㧜㧜㧠㧜ޓ
ޓ
ޓ㧺㧲㧝ޓ㧺㧲㧞ޓޓޓ㧭㧾㧱㧿
5
5-41
5-42
5 Adjustments
5.5.2 One-parameter Tuning Procedure
Friction Compensation
This function compensates for changes in the following conditions.
• Changes in the viscous resistance of the lubricant, such as the grease, on the sliding parts of the machine
• Changes in the friction resistance resulting from variations in the machine assembly
• Changes in the friction resistance due to aging
Conditions to which friction compensation is applicable depend on the tuning mode. The friction compensation setting in F408.3 applies when the mode is 0 or 1. Tuning Mode = 2 and Tuning Mode = 3 are adjusted with the friction compensation function regardless of the friction compensation setting in P408.3.
Friction
Compensation
Selecting
Pn408 n.0
[Factory setting]
Mode n.1
Tuning Mode = 0 Tuning Mode = 1 Tuning Mode = 2 Tuning Mode = 3
Adjusted without the friction compensation function
Adjusted without the friction compensation function
Adjusted with the friction compensation function
Adjusted with the friction compensation function
Adjusted with the friction compensation function
Adjusted with the friction compensation function
Feedforward
If Pn140 is set to the factory setting and the tuning mode setting is changed to 2 or 3, the feedforward gain
(Pn109), speed feedforward (VFF) input, and torque feedforward (TFF) input will be disabled.
Set Pn140.3 to 1 if model following control is used together with the speed feedforward (VFF) input and torque feedforward (TFF) input from the host controller.
Function When Enabled Classification
Pn140
Parameter n.0
[Factory setting] n.1
Model following control is not used together with the speed/torque feedforward input.
Model following control is used together with the speed/torque feedforward input.
Immediately Tuning
Refer to Σ -V Series User’s Manual MECHATROLINK-II Commands (No.: SIEP S800000 54) for details.
• Model following control is used to make optimum feedforward settings in the SERVO-
PACK when model following control is used with the feedforward function. Therefore, model following control is not normally used together with either the speed feedforward (VFF) input or torque feedforward (TFF) input from the host controller. However, model following control can be used with the speed feedforward (VFF) input or torque feedforward (TFF) input if required. An improper feedforward input may result in overshooting.
5.5 One-parameter Tuning (Fn203)
5.5.3
One-parameter Tuning Example
The following procedure is used for one-parameter tuning on the condition that the tuning mode is set to 2 or
3. This mode is used to reduce positioning time.
Step Measuring Instrument Display Example
1
Position error
Reference speed
M
E
C
H
A
Operation
Measure the positioning time after setting the moment of inertia ratio (Pn103) correctly. Tuning will be completed if the specifications are met here. The tuning results will be saved in the SERVOPACK.
Positioning completed signal
2
The positioning time will become shorter if the FF level is increased. The tuning will be completed if the specifications are met. The tuning results will be saved in the SERVOPACK.
If overshooting occurs before the specifications are met, go to step 3.
3
4
5 –
Overshooting will be reduced if the FB level is increased. If the overshooting is eliminated, go to step 4.
The graph shows overshooting generated with the FF level increased after step 3. In this state, the overshooting occurs, but the positioning settling time is shorter. The tuning will be completed if the specifications are met. The adjustment results are saved in the SERVOPACK. If overshooting occurs before the specifications are met, repeat steps 3 and 4.
If vibration occurs before the overshooting is eliminated, the vibration will be suppressed by the automatic notch filter and anti-resonance control.
Note: The vibration frequencies may not be detected if the vibration is too small. If that occurs, press the to forcibly detect the vibration frequencies.
Key
The adjustment results are saved in the SERVOPACK.
5
5-43
5-44
5 Adjustments
5.5.4 Related Parameters
5.5.4
Related Parameters
The following table lists parameters related to this function and their possibility of being changed while executing this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes : Parameters can be changed using SigmaWin+ while this function is being executed.
No : Parameters cannot be changed using SigmaWin+ while this function is being executed.
• Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
Parameter
Pn125
Pn401
Pn408
Pn409
Pn40A
Pn40C
Pn40D
Pn140
Pn100
Pn101
Pn102
Pn103
Pn121
Pn123
Pn124
Pn141
Pn142
Pn143
Pn144
Pn145
Pn146
Pn147
Pn160
Pn161
Pn163
Name
Speed Loop Gain
Speed Loop Integral Time Constant
Position Loop Gain
Moment of Inertia Ratio
Friction Compensation Gain
Friction Compensation Coefficient
Friction Compensation Frequency Correction
Friction Compensation Gain Correction
Torque Reference Filter Time Constant
Torque Related Function Switch
1st Notch Filter Frequency
1st Notch Filter Q Value
2nd Notch Filter Frequency
2nd Notch Filter Q Value
Model Following Control Related Switch
Model Following Control Gain
Model Following Control Gain Compensation
Model Following Control Bias (Forward Direction)
Model Following Control Bias (Reverse Direction)
Vibration Suppression 1 Frequency A
Vibration Suppression 1 Frequency B
Model Following Control Speed Feedforward Compensation
Anti-Resonance Control Related Switch
Anti-Resonance Frequency
Anti-Resonance Damping Gain
No
No
No
No
No
Yes
No
No
No
Yes
No
No
Mid-execution changes
No
No
No
No
No
Yes
No
No
No
No
No
No
No
Yes
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Automatic changes
Yes
Yes
Yes
No
Yes
5.6 Anti-Resonance Control Adjustment Function (Fn204)
5.6
Anti-Resonance Control Adjustment Function (Fn204)
This section describes the anti-resonance control adjustment function.
5.6.1
Anti-Resonance Control Adjustment Function
The anti-resonance control adjustment function increases the effectiveness of the vibration suppression after one-parameter tuning. This function is effective in supporting anti-resonance control adjustment if the vibration frequencies are from 100 to 1000 Hz.
This function rarely needs to be used because it is automatically set by the advanced autotuning or advanced autotuning by reference input. Use this function only if fine-tuning is required, or vibration detection is failed and readjustment is required.
Perform one-parameter tuning (Fn203) or use another method to improve the response characteristics after performing this function. If the anti-resonance gain is increased with one-parameter tuning performed, vibration may result again. If that occurs, perform this function again to fine-tune the settings.
CAUTION
• If this function is executed, related parameters will be set automatically. Therefore, there will be a large response change after this function is executed. Enable the function in a state where the machine can come to an emergency stop at any time to ensure the safety operation of the machine.
• Be sure to set a suitable value for the moment of inertia ratio (Pn103) using advanced autotuning before executing the anti-resonance control adjustment function. If the setting greatly differs from the actual moment of inertia ratio, normal control of the machine may not be possible, and vibration may result.
• This function detects vibration between 100 and 1000 Hz. Vibration will not be detected for frequencies outside of this range, and instead, "F----" will be displayed. If that occurs, use one-parameter tuning with tuning mode 2 selected to automatically set a notch filter or use the vibration suppression function (Fn205).
• Vibration can be reduced more effectively by increasing the anti-resonance damping gain (Pn163). The amplitude of vibration may become larger if the damping gain is excessively high. Increase the damping gain from about 0% to 200% in 10% increments while checking the effect of vibration reduction. If the effect of vibration reduction is still insufficient at a gain of 200%, cancel the setting, and lower the control gain using a different method, such as one-parameter tuning.
(1) Before Performing Anti-Resonance Control Adjustment Function
Check the following settings before performing anti-resonance control adjustment function.
The message “NO-OP” indicating that the settings are not appropriate will be displayed, if all of the following conditions are not met.
• The tuning-less function must be disabled (Pn170.0 = 0).
• The test without a motor function must be disabled (Pn00C.0 = 0).
• The control must not be set to torque control.
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
5
5-45
5-46
5 Adjustments
5.6.2 Anti-Resonance Control Adjustment Function Operating Procedure
5.6.2
Anti-Resonance Control Adjustment Function Operating Procedure
With this function, an operation reference is sent, and the function is executed while vibration is occurring.
Anti-resonance control adjustment function is performed from the digital operator (option) or SigmaWin+.
The following methods can be used for the anti-resonance control adjustment function.
• Using anti-resonance control for the first time
• With undetermined vibration frequency
• With determined vibration frequency
• For fine-tuning after adjusting the anti-resonance control
The following describes the operating procedure from the digital operator.
Refer to the Σ -V Series User’s Manual, Operation of Digital Operator operations of the digital operator.
(No.: SIEP S800000 55) for basic key
(1) Using Anti-Resonance Control for the First Time
With Undetermined Vibration Frequency
Step
1
2
Display after Operation
㧾㨁㧺ޓ ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
㧲㨚㧞㧜㧠㧦㧭㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧡㧦㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧢㧦㧱㨍㨟㨥ޓ㧲㧲㨀
Status Display
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨀㨡㨚㨕㨚㨓 㧹㨛㨐㨑 㧩 㧜
Keys Operation
Press the Key to view the main menu for the utility function.
Use the select Fn204.
or Key to move through the list,
Press the Key to display the initial setting screen for tuning mode.
3
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨀㨡㨚㨕㨚㨓 㧹㨛㨐㨑 㧩 㧜
4
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧙㧙㧙㧙 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧜㧜㧜
Press the or
"0."
Key and set the tuning mode
Press the Key while "Tuning Mode = 0" is displayed. The screen shown on the left will appear. The detection of vibration frequencies will start and
"freq" will flash. Return to step 3 if vibration is not detected.
Note: If vibration is not detected even when vibration is occurring, lower the vibration detection sensitivity (Pn311). When this parameter is lowered, the detection sensitivity will be increased.
Vibration may not be detected accurately if too small value is set.
The vibration frequency will be displayed in “freq” if vibration is detected.
Rotati on
5
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧜㧜㧜
–
Example of measured waveform
5.6 Anti-Resonance Control Adjustment Function (Fn204)
Step
6
Display after Operation
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧜㧜㧜
Keys
(cont’d)
Operation
Press the Key. The cursor will move to "damp," and the flashing of "freq" will stop.
the or
Key, press
Key to set the damping gain.
Rotati on
7
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧝㧞㧜
8
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧝㧞㧜
9
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧞㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧝㧞㧜
10
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧞㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧝㧞㧜
11
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
㧲㨚㧞㧜㧠㧦㧭㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧡㧦㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧢㧦㧱㨍㨟㨥ޓ㧲㧲㨀
Example of measured waveform
Note: Increase the damping gain from about 0% to
200% in 10% increments while checking the effect of vibration reduction. If vibration reduction is still insufficient at a gain of 200%, cancel the setting, and lower the control gain by using a different method, such as one-parameter tuning.
If fine tuning of the frequency is necessary, press the
Key. The cursor will move from "damp" to
"freq." If fine-tuning is not necessary, skip step 9 and go to step 10. the or
Key, press
Key to fine-tune the frequency.
Press the Key to save the settings. "DONE" will flash for approximately two seconds and "RUN" will be displayed.
Press the Key to complete the anti-resonance control adjustment function. The screen in step 1 will appear again.
5
5-47
5-48
5 Adjustments
5.6.2 Anti-Resonance Control Adjustment Function Operating Procedure
With Determined Vibration Frequency
Step
1
Display after Operation
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
㧲㨚㧞㧜㧠㧦㧭㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧡㧦㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧢㧦㧱㨍㨟㨥ޓ㧲㧲㨀
2
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨀㨡㨚㨕㨚㨓 㧹㨛㨐㨑 㧩 㧜
Keys
3
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㨀㨡㨚㨕㨚㨓 㧹㨛㨐㨑 㧩 㧝
4
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧝㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧜㧜㧜
Operation
Press the Key to view the main menu for the utility function.
Use the select Fn204.
or Key to move through the list,
Press the Key to display the initial setting screen for tuning mode.
Press the or
"1."
Key and set the tuning mode
Press the Key while "Tuning Mode = 1" is displayed. The screen shown on the left will appear and
"freq" will flash.
Rotati on
5
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧝㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧜㧜㧜
6
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧜㧜㧜
Example of measured waveform
Select the digit with the the or
or Key, and press
Key to adjust the frequency.
Press the Key. The cursor will move to "damp."
Select the digit with the the or
or Key, and press
Key to adjust the damping gain.
Rotati on
7
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧜㧞㧜
Example of measured waveform
Note: Increase the damping gain from about 0% to
200% in 10% increments while checking the effect of vibration reduction. If vibration reduction is still insufficient at a gain of 200%, cancel the setting, and lower the control gain by using a different method, such as one-parameter tuning.
5.6 Anti-Resonance Control Adjustment Function (Fn204)
Step
8
Display after Operation
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧝㧞㧜
9
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧝㧞㧜
10
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧝㧞㧜
11
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
㧲㨚㧞㧜㧠㧦㧭㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧡㧦㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧢㧦㧱㨍㨟㨥ޓ㧲㧲㨀
Keys
(cont’d)
Operation
If fine tuning of the frequency is necessary, press the
Key. The cursor will move from "damp" to
"freq." If fine-tuning is not necessary, skip step 9 and go to step 10. the or
Key, press
Key to fine-tune the frequency.
Press the Key to save the settings. "DONE" will flash for approximately two seconds and "RUN" will be displayed.
Press the Key to complete the anti-resonance control adjustment function. The screen in step 1 will appear again.
5
5-49
5-50
5 Adjustments
5.6.2 Anti-Resonance Control Adjustment Function Operating Procedure
(2) For Fine-tuning After Adjusting the Anti-Resonance Control
Keys Step
1
Display after Operation
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
㧲㨚㧞㧜㧠㧦㧭㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧡㧦㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧢㧦㧱㨍㨟㨥ޓ㧲㧲㨀
2
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㨀㨡㨚㨕㨚㨓 㧹㨛㨐㨑 㧩 㧝
Operation
Press the Key to view the main menu for the utility function.
Use the select Fn204.
or Key to move through the list,
Press the Key to display the "Tuning Mode = 1" as shown on the left.
3
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧝㧞㧜
4
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧝㧡㧜
5
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧜㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧝㧡㧜
6
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧞㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧝㧡㧜
7
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨒㨞㨑㨝 㧩 㧜㧠㧞㧜 㧴㨦
㨐㨍㨙㨜 㧩 㧜㧝㧡㧜
8
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
㧲㨚㧞㧜㧠㧦㧭㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧡㧦㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧢㧦㧱㨍㨟㨥ޓ㧲㧲㨀
Press the Key while "Tuning Mode = 1" is displayed. The screen shown on the left will appear and
"damp" will flash.
Select the digit with the or Key, and press the or Key to set the damping gain.
Note: Increase the damping gain from about 0% to
200% in 10% increments while checking the effect of vibration reduction. If vibration reduction is still insufficient at a gain of 200%, cancel the setting, and lower the control gain by using a different method, such as one-parameter tuning.
If fine tuning of the frequency is necessary, press the
Key. The cursor will move from "damp" to
"freq." If fine-tuning is not necessary, skip step 6 and go to step 7.
Select the digit with the the or
or Key, and press
Key to fine-tune the frequency.
Press the Key to save the settings. "DONE" will flash for approximately two seconds and "RUN" will be displayed.
Press the Key to complete the anti-resonance control adjustment function. The screen in step 1 will appear again.
5.6 Anti-Resonance Control Adjustment Function (Fn204)
5.6.3
Related Parameters
The following table lists parameters related to this function and their possibility of being changed while executing this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes : Parameters can be changed using SigmaWin+ while this function is being executed.
No : Parameters cannot be changed using SigmaWin+ while this function is being executed.
• Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
Parameter
Pn160
Pn161
Pn162
Pn163
Pn164
Pn165
Name
Anti-Resonance Control Related Switch
Anti-Resonance Frequency
Anti-Resonance Gain Compensation
Anti-Resonance Damping Gain
Anti-Resonance Filter Time Constant 1 Compensation
Anti-Resonance Filter Time Constant 2 Compensation
Mid-execution changes
Yes
No
Yes
No
Yes
Yes
Automatic changes
Yes
Yes
No
Yes
No
No
5
5-51
5-52
5 Adjustments
5.7.1 Vibration Suppression Function
5.7
Vibration Suppression Function (Fn205)
The vibration suppression function is described in this section.
5.7.1
Vibration Suppression Function
The vibration suppression function suppresses transitional vibration at frequency as low as 1 to 100 Hz that is generated mainly when positioning if the machine stand vibrates.
This function is set automatically when advanced autotuning or advanced autotuning by reference is executed.
In most cases, this function is not necessary. Use this function only if fine-tuning is required or readjustment is required as a result of a failure to detect vibration.
Perform one-parameter tuning (Fn203) if required to improve the response characteristics after performing this function.
CAUTION
• If this function is executed, related parameters will be set automatically. Therefore, there will be a large response change after this function is enabled or disabled. Enable the function in a state where the machine can come to an emergency stop at any time to ensure the safety operation of the machine.
• Be sure to set a suitable value for the moment of inertia ratio (Pn103) using advanced autotuning before executing the vibration suppression function. If the setting greatly differs from the actual moment of inertia ratio, normal control of the SERVOPACK may not be possible, and vibration may result.
• Phase control of the MP2000 Series may not be possible, if the vibration suppression function is performed when using the MP2000 Series with phase control.
• This function detects vibration frequency between 1 to 100 Hz. Vibration will not be detected for frequencies outside of this range, and instead, "F-----" will be displayed.
• Frequency detection will not be performed if no vibration results from position error or the vibration frequencies are outside the range of detectable frequencies. If so, use a device, such as a displacement sensor or vibration sensor, to measure the vibration frequency.
• If vibration frequencies automatically detected are not suppressed, the actual frequency and the detected frequency may differ. Fine-tune the detected frequency if necessary.
(1) Preparation
Check the following settings before performing the vibration suppression function.
The message “NO-OP” indicating that the settings are not appropriate will be displayed, if all of the following conditions are not met.
• The control must be set to position control.
• The tuning-less function must be disabled (Pn170.0 = 0).
• The test without a motor function must be disabled (Pn00C.0 = 0).
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
(2) Items Influencing Performance
If continuous vibration occurs when the servomotor is not rotating, the vibration suppression function cannot be used to suppress the vibration effectively. If the result is not satisfactory, perform anti-resonance control adjustment function (Fn204) or one-parameter tuning (Fn203).
5.7 Vibration Suppression Function (Fn205)
(3) Detection of Vibration Frequencies
Frequency detection may not be possible if there is not enough vibration to affect the position error.
The detection sensitivity can be adjusted by changing the setting for the remained vibration detection width
(Pn560) which is set as a percentage of the positioning completed width (Pn522). Perform the detection of vibration frequencies again after adjusting the remained vibration detection width (Pn560).
Remained Vibration Detection Width
Position
Setting Unit
0.1%
Factory Setting
400
When Enabled
Immediately
Classification
Pn560
Setting Range
1 to 3000 Setup
Note: As a guideline, change the setting 10% at a time. The smaller the set value is, the higher the detection sensitivity will be. If the value is too small, however, the vibration may not be detected accurately.
The vibration frequencies that are automatically detected may vary somewhat with each positioning operation.
Perform positioning several times and make adjustments while checking the effect of vibration suppression.
5.7.2
Vibration Suppression Function Operating Procedure
The following procedure is used for vibration suppression function.
Vibration suppression function is performed from the digital operator (option) or SigmaWin+.
The operating procedure from the digital operator is described here.
Refer to the Σ -V Series User’s Manual, Operation of Digital Operator operations of the digital operator.
(No.: SIEP S800000 55) for basic key
Note: If this function is aborted by pressing the MODE/SET Key, the SERVOPACK will continue operating until the servomotor comes to a stop. After the servomotor stops, the set value will return to the previous value.
The operating flow of the vibration suppression function is shown below.
(1) Operating Flow
Execute steps 1 to 3 in the following page.
Vibration detected?
Yes
Execute steps 4 to 8 in the following page.
No
Adjust vibration using measuring device.
Completed
5
5-53
5-54
5 Adjustments
5.7.2 Vibration Suppression Function Operating Procedure
(2) Operating Procedure
Step Display after Operation Keys Operation
1 Input a operation reference and take the following steps while repeating positioning.
2
3
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧠㧦㧭㧙㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧡㧦㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧢㧦㧱㨍㨟㨥ޓ㧲㧲㨀
㧲㨚㧞㧜㧣㧦㨂㧙㧹㨛㨚㨕㨠㨛㨞
㧾㨁㧺 ̆㨂㨕㨎 㧿㨡㨜̆
㧹㨑㨍㨟㨡㨞㨑 㨒㧩㧜㧝㧜㧚㧠㧴㨦
㧿㨑㨠㨠㨕㨚㨓 㨒㧩㧜㧡㧜㧚㧠㧴㨦
Press the Key to view the main menu for the utility function.
Use the select Fn205.
or Key to move through the list,
Press the Key. The display shown on the left will appear.
Measure f: Measurement frequency
Setting f: Setting frequency [Factory-set to the set value for Pn145]
If the setting frequency and actual operating frequency are different, "Setting" will flash.
Note:
Frequency detection will not be performed if there is no vibration or the vibration frequency is outside the range of detectable frequencies.
The following screen will be displayed if vibration is not detected. If the vibration frequencies are not detected, prepare a means of detecting and measuring the vibration. When the vibration frequencies are measured, go to step 5 and manually set the measured vibration frequency to “Setting f.”
㧾㨁㧺 ̆㨂㨕㨎 㧿㨡㨜̆
㧹㨑㨍㨟㨡㨞㨑㨒 㧩㧙㧙㧙㧙㧙㧴㨦
㧿㨑㨠㨠㨕㨚㨓㨒 㧩㧜㧡㧜㧚㧜㧴㨦
4
㧾㨁㧺 ̆㨂㨕㨎 㧿㨡㨜̆
㧹㨑㨍㨟㨡㨞㨑 㨒㧩㧜㧝㧜㧚㧠㧴㨦
㧿㨑㨠㨠㨕㨚㨓 㨒㧩㧜㧝㧜㧚㧠㧴㨦
Press the Key. The displayed “Measure f” value will be displayed as the “Setting f” value as well.
Rotation
Position
Error
5
㧾㨁㧺 ̆㨂㨕㨎 㧿㨡㨜̆
㧹㨑㨍㨟㨡㨞㨑 㨒㧩㧜㧝㧜㧚㧠㧴㨦
㧿㨑㨠㨠㨕㨚㨓 㨒㧩㧜㧝㧞㧚㧠㧴㨦
Torque reference
Example of measured waveform
If the vibration is not completely suppressed, select the digit with the or Key, and press the
or Key to fine-tune the frequency “setting f.” Skip this step and go to step 7 if the fine-tuning of the frequency is not necessary.
Note: If the setting frequency and actual operating frequency are different, "Setting" will flash.
5.7 Vibration Suppression Function (Fn205)
Step Display after Operation
6
㧾㨁㧺 ̆㨂㨕㨎 㧿㨡㨜̆
㧹㨑㨍㨟㨡㨞㨑 㨒㧩㧜㧝㧜㧚㧠㧴㨦
㧿㨑㨠㨠㨕㨚㨓 㨒㧩㧜㧝㧞㧚㧠㧴㨦
Keys
(cont’d)
Operation
Press the Key. The "Setting f" will change to usual display and the frequency currently displayed will be set for the vibration suppression function
.
Rotation
Position
Error
7
㧾㨁㧺 ޓޓ ̆㨂㨕㨎 㧿㨡㨜̆
㧹㨑㨍㨟㨡㨞㨑㨒 㧩㧙㧙㧙㧙㧙㧴㨦
㧿㨑㨠㨠㨕㨚㨓㨒 㧩㧜㧝㧞㧚㧠㧴㨦
Torque reference
Example of measured waveform
Press the Key to save the setting. "DONE" will flash for approximately two seconds and "RUN" will be displayed again.
8
㧾㨁㧺 ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧠
㧲㨚㧞㧜㧡
㧲㨚㧞㧜㧢
㧲㨚㧞㧜㧣
Press the Key to complete the vibration suppression function. The screen in step 1 will appear again.
No settings related to the vibration suppression function will be changed during operation.
If the servomotor does not stop approximately 10 seconds after the setting changes, a timeout error will result and the previous setting will be automatically enabled again.
The vibration suppression function will be enabled in step 6. The motor response, however, will change when the servomotor comes to a stop with no reference input.
(3) Related Function on Vibration Suppression Function
This section describes functions related to vibration suppression function.
Feedforward
The feedforward gain (Pn109), speed feedforward (VFF) input, and torque feedforward (TFF) input will be disabled in the factory setting.
Set Pn140.3 to 1 if model following control is used together with the speed feedforward (VFF) input and torque feedforward (TFF) input from the host controller.
Pn140
Parameter n.0
[Factory setting] n.1
Function
Model following control is not used together with the speed/torque feedforward input.
Model following control is used together with the speed/torque feedforward input.
When Enabled Classification
Immediately Tuning
Refer to Σ -V Series User’s Manual MECHATROLINK-II Commands (No.: SIEP S800000 54) for details.
5
5-55
5-56
5 Adjustments
5.7.3 Related Parameters
• Model following control is used to make optimum feedforward settings in the SERVO-
PACK when model following control is used with the feedforward function. Therefore, model following control is not normally used together with either the speed feedforward (VFF) input or torque feedforward (TFF) input from the host controller. However, model following control can be used with the speed feedforward (VFF) input or torque feedforward (TFF) input if required. An improper feedforward input may result in overshooting.
5.7.3
Related Parameters
The following table lists parameters related to this function and their possibility of being changed while executing this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes : Parameters can be changed using SigmaWin+ while this function is being executed.
No : Parameters cannot be changed using SigmaWin+ while this function is being executed.
• Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
Parameter
Pn140
Pn141
Pn142
Pn143
Pn144
Pn145
Pn146
Pn147
Pn14A
Pn14B
Name
Model Following Control Related Switch
Model Following Control Gain
Model Following Control Gain Compensation
Model Following Control Bias (Forward Direction)
Model Following Control Bias (Reverse Direction)
Vibration Suppression 1 Frequency A
Vibration Suppression 1 Frequency B
Model Following Control Speed Feedforward Compensation
Vibration Suppression 2 Frequency
Vibration Suppression 2 Compensation
Mid-execution changes
Yes
No
No
No
No
No
No
No
No
No
Automatic changes
Yes
Yes
No
No
No
Yes
Yes
No
No
No
5.8 Additional Adjustment Function
5.8
Additional Adjustment Function
This section describes the functions that can be used for additional fine tuning after making adjustments with advanced autotuning, advanced autotuning by reference, or one-parameter tuning.
• Switching gain settings
• Friction compensation
• Current control mode selection
• Current gain level setting
• Speed detection method selection
5.8.1
Switching Gain Settings
Two gain switching functions are available, manual switching and automatic switching. The manual switching function uses an external input signal to switch gains, and the automatic switching function switches gains automatically.
By using the gain switching function, the positioning time can be shortened by increasing the gain during positioning and vibration can be suppressed by decreasing the gain while it is stopped.
Pn139
Note: n.
Parameter n.
0
[Factory setting] n.
2
Function
Manual gain switching
Automatic gain switching
1 is reserved. Do not use.
When Enabled Classification
Immediately
For the gain combinations for switching, refer to (1) Gain Combinations for Switching .
Tuning
For the manual gain switching, refer to (2) Manual Gain Switching .
For the automatic gain switching, refer to (3) Automatic Gain Switching .
(1) Gain Combinations for Switching
Setting
Gain
Setting 1
Gain
Setting 2
Speed Loop
Gain
Pn100
Speed Loop
Gain
Pn104
2nd Speed Loop
Gain
Speed Loop
Integral Time
Constant
Pn101
Speed Loop
Integral Time
Constant
Pn105
2nd Speed Loop
Integral Time
Constant
Position Loop
Pn102
Position Loop
Gain
Gain
Pn106
2nd Position
Loop Gain
Torque Reference
Filter
Pn401
Torque Reference Filter Time
Constant
Model
Following
Control Gain
Pn141
Model Following Control
Gain
*
Pn412
1st Step 2nd
Torque Reference Filter Time
Constant
Pn148
*
2nd Model Following Control
Gain
Model
Following
Control Gain
Compensation
Pn142
*
Model Following Control
Gain Compensation
Pn149
*
2nd Model Following Control
Gain Compensation
Friction
Compensation
Gain
Pn121
Friction Compensation Gain
Pn122
2nd Gain for
Friction
Compensation
∗ The switching gain settings for the model following control gain and the model following control gain compensation are available only for manual gain switching. To enable the gain switching of these parameters, a gain switching input signal must be sent, and the following conditions must be met.
• No command being executed.
• Motor having been completely stopped.
If these conditions are not satisfied, the applicable parameters will not be switched although the other parameters shown in this table will be switched.
5
5-57
5-58
5 Adjustments
5.8.1 Switching Gain Settings
(2) Manual Gain Switching
Manual gain switching uses G-SEL of OPTION field to switch between gain setting 1 and gain setting 2.
Type Command Name
Input G-SEL of OPTION field
0
1
Setting Meaning
Switches to gain setting 1.
Switches to gain setting 2.
(3) Automatic Gain Switching
Automatic gain switching is enabled only in position control. The switching conditions are specified using the following settings.
Parameter Setting
Pn139 n.
2
Switching Condition
Condition A satisfied.
Condition A not satisfied.
Setting
Gain setting 1 to gain setting 2
Gain setting 2 to gain setting 1
Select one of the following settings for switching condition A.
Pn139
Parameter
Switching Condition A for Position Control
For Other than
Position Control
(No Switching) n.
0
[Factory setting] n.
n.
n.
n.
n.
1
2
3
4
5
Positioning completed signal (/COIN) ON
Positioning completed signal (/COIN) OFF
Positioning near signal
(/NEAR) ON
Positioning near signal
(/NEAR) OFF
No output for position reference filter and position reference input OFF
Position reference input
ON
Fixed in gain setting 1
Fixed in gain setting 2
Fixed in gain setting 1
Fixed in gain setting 2
Fixed in gain setting 1
Fixed in gain setting 2
Switching Wait
Time
Pn135
Gain Switching
Waiting Time 1
Pn136
Gain Switching
Waiting Time 2
When
Enabled
Immediately
Switching Time
Pn131
Gain Switching
Time 1
Pn132
Gain Switching
Time 2
Classification
Tuning
Automatic switching pattern 1 (Pn139.0 = 2)
Condition A satisfied
Switching Waiting Time 1 Pn135
Switching Time 1 Pn131
Gain
Settings 1
Pn100
Pn101
Pn102
Pn121
Pn401
Switching Waiting Time 2 ޓ Pn136
Switching Time 2 ޓ Pn132
Condition A not satisfied
Gain
Settings 2
Pn104
Pn105
Pn106
Pn122
Pn412
5.8 Additional Adjustment Function
Relationship between the Waiting and Switching Times for Gain Switching
In this example, the "positioning completed signal (/COIN) ON" condition is set as condition A for automatic gain switching. The position loop gain is switched from the value in Pn102 (position loop gain) to the value in
Pn106 (2nd position loop gain). When the /COIN signal goes ON, the switching operation begins after the waiting time set in Pn135. The switching operation changes the position loop gain linearly from Pn102 to
Pn106 within the switching time set in Pn131.
Pn102
Position Loop Gain
Switching
Waiting Time
Pn135
Switching Time
Pn131
Pn106
2nd Position
Loop Gain
/COIN
Switching condition A satisfied
Note: Automatic gain switching is available in the PI and I-P controls (Pn10B).
(4) Related Parameters
Pn100
Pn101
Pn102
Speed Loop Gain
Setting Range
10 to 20000
Setting Unit
0.1 Hz
Speed Loop Integral Time Constant
Setting Range
15 to 51200
Setting Unit
0.01 ms
Position Loop Gain
Setting Range
10 to 20000
Setting Unit
0.1/s
Pn401
Torque Reference Filter Time Constant
Setting Range
0 to 65535
Setting Unit
0.01 ms
Pn141
Model Following Control Gain
Setting Range
10 to 20000
Setting Unit
0.1/s
Pn142
Model Following Control Gain Compensation
Setting Range
500 to 2000
Friction Compensation Gain
Setting Unit
0.1%
Pn121
Pn104
Setting Range
10 to 1000
2nd Speed Loop Gain
Setting Range
10 to 20000
Setting Unit
1%
Setting Unit
0.1 Hz
500
Speed
Factory Setting
400
Speed
Factory Setting
2000
Factory Setting
400
Speed Position
Factory Setting
100
Factory Setting
Factory Setting
1000
Speed
Factory Setting
100
Speed
Factory Setting
400
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
Torque
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
5
5-59
5-60
5 Adjustments
5.8.1 Switching Gain Settings
2nd Speed Loop Integral Time Constant
Factory Setting
2000
Speed
Pn105
Setting Range
15 to 51200
2nd Position Loop Gain
Pn106
Pn412
Pn148
Pn149
Pn122
Setting Unit
0.01 ms
Setting Range
10 to 20000
Setting Unit
0.1/s
1st Step 2nd Torque Reference Filter Time
Constant
Setting Range Setting Unit
0 to 65535 0.01 ms
Setting Range
500 to 2000
Setting Unit
0.1%
2nd Gain for Friction Compensation
Factory Setting
Speed
400
Position
Factory Setting
100
2nd Model Following Control Gain
Setting Range
10 to 20000
Setting Unit
0.1/s
2nd Model Following Control Gain Compensation
Factory Setting
500
Factory Setting
1000
Setting Range
10 to 1000
Setting Unit
1%
Speed
Factory Setting
100
Position
When Enabled
Immediately
Position
When Enabled
Immediately
(cont’d)
Classification
Tuning
Classification
Tuning
Torque
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
(5) Parameters for Automatic Gain Switching
Pn131
Pn132
Pn135
Pn136
Gain Switching Time 1
Setting Range
0 to 65535
Gain Switching Time 2
Setting Unit
1 ms
Setting Range
0 to 65535
Setting Unit
Gain Switching Waiting Time 1
1 ms
Setting Range
0 to 65535
Setting Unit
Gain Switching Waiting Time 2
1 ms
Setting Range
0 to 65535
Setting Unit
1 ms
Factory Setting
0
Factory Setting
0
Factory Setting
0
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
Factory Setting
0
(6) Related Monitor
Monitor No. (Un)
Un014
Name
Effective gain monitor
Value
1
2
For gain setting 1
Remarks
For gain setting 2
Note: When using the tuning-less function, gain setting 1 is enabled.
Parameter No.
Analog Monitor
Name Output Value
Pn006
Pn007 n.
0B
Effective gain monitor
1 V
2 V
Remarks
Gain setting 1 is enabled.
Gain setting 2 is enabled.
5.8 Additional Adjustment Function
5.8.2
Manual Adjustment of Friction Compensation
Friction compensation rectifies the viscous friction change and regular load change.
The friction compensation function can be automatically adjusted with advanced autotuning (Fn201), advanced autotuning by reference input (Fn202), or one-parameter tuning (Fn203). This section describes the steps to follow if manual adjustment is required.
(1) Required Parameter Settings
The following parameter settings are required to use friction compensation.
Pn408
Parameter n.0
[Factory setting] n.1
Function
Does not use friction compensation.
Uses friction compensation.
When Enabled Classification
Immediately Setup
Pn121
Pn123
Pn124
Pn125
Friction Compensation Gain
Setting Range
10 to 1000
Setting Unit
1%
Friction Compensation Coefficient
Setting Range
0 to 100
Setting Unit
1%
Friction Compensation Frequency Correction
Setting Range
-10000 to 10000
Setting Unit
0.1 Hz
Friction Compensation Gain Correction
Setting Range
1 to 1000
Setting Unit
1%
Speed
Factory Setting
100
Speed
Factory Setting
0
Speed
Factory Setting
0
Speed
Factory Setting
100
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
Position
When Enabled
Immediately
Classification
Tuning
5
5-61
5-62
5 Adjustments
5.8.2 Manual Adjustment of Friction Compensation
(2) Operating Procedure for Friction Compensation
The following procedure is used for friction compensation.
CAUTION
• Before using friction compensation, set the moment of inertia ratio (Pn103) as accurately as possible. If the wrong moment of inertia ratio is set, vibration may result.
Step
1
Operation
Set the following parameters for friction compensation to the factory setting as follows.
Friction compensation gain (Pn121): 100
Friction compensation coefficient (Pn123): 0
Friction compensation frequency correction (Pn124): 0
Friction compensation gain correction (Pn125): 100
Note: Always use the factory-set values for friction compensation frequency correction (Pn124) and friction compensation gain correction (Pn125).
To check the effect of friction compensation, gradually increase the friction compensation coefficient (Pn123).
Note: Usually, set the friction compensation coefficient value to 95% or less. If the effect is insufficient, increase the friction compensation gain (Pn121) by 10% increments until it stops vibrating.
2
Effect of Parameters for Adjustment
Pn121: Friction Compensation Gain
This parameter sets the responsiveness for external disturbance. The higher the set value is, the better the responsiveness will be. If the equipment has a resonance frequency, however, vibration may result if the set value is excessively high.
Pn123: Friction Compensation Coefficient
This parameter sets the effect of friction compensation. The higher the set value is, the more effective friction compensation will be. If the set value is excessively high, however, the vibration will occur easily. Usually, set the value to 95% or less.
Effect of Adjustment
The following graph shows the responsiveness with and without proper adjustment.
Insufficient responsiveness because of friction
Small friction
Responsiveness
ᡂᄢ㧘ᡂዊ friction compensation.
MECHA
3
Large friction
Without friction compensation With friction compensation
5.8 Additional Adjustment Function
5.8.3
Current Control Mode Selection Function
This function reduces high-frequency noises while the servomotor is being stopped. This function is enabled by default.
Pn009
Parameter n. 0 n. 1
[Factory setting]
Meaning
Selects the current control mode 1.
Selects the current control mode 2 (low noise).
When Enabled
After restart
Classification
Tuning
• If current control mode 2 is selected, the load ratio may increase while the servomotor is being stopped.
5.8.4
Current Gain Level Setting
This function reduces noises by adjusting the parameter value for current control inside the SERVOPACK according to the speed loop gain (Pn100). The noise level can be reduced by reducing the current gain level
(Pn13D) from its factory setting of 2000% (disabled). If the set value of Pn13D is decreased, the level of noise will be lowered, but the response characteristics of the SERVOPACK will also be degraded. Adjust the current gain level within the allowable range at which SERVOPACK response characteristics can be secured.
Pn13D
Current Gain Level
Setting Range
100 to 2000
Speed Position
Factory Setting
2000
When Enabled
Immediately
Classification
Setting Unit
1% Tuning
• If the parameter setting of the current gain level is changed, the responses characteristics of the speed loop will also change. The SERVOPACK must, therefore, be readjusted again.
5.8.5
Speed Detection Method Selection
This function can ensure smooth movement of the servomotor while the servomotor is running. Set the value of Pn009.2 to 1 and select speed detection 2 to smooth the movement of the servomotor while the servomotor is running.
Pn009
Parameter n. 0
[Factory setting] n. 1
Meaning
Selects speed detection 1.
Selects speed detection 2.
When Enabled
After restart
Classification
Tuning
• If the speed detection method is changed, the response characteristics of the speed loop will change and the SERVOPACK must be readjusted again.
5
5-63
5-64
5 Adjustments
5.8.6 Backlash Compensation Function
5.8.6
Backlash Compensation Function
(1) Overview
When driving a machine with backlash, there will be a deviation between the travel distance in the position reference that is managed by the host controller and the travel distance of the actual machine. Use backlash compensation function to add the backlash compensation value to the position reference and use the result to drive the servomotor. This means that the travel distance of the actual machine will be the same as the travel distance in the host controller.
Note: This function is supported only for position control.
Travel distance by position reference
Machine axis
Backlash compensation value
Travel distance by position reference
MECHA
Motor axis
Reference forward rotational direction
Machine axis (e.g. table)
Motor axis
Backlash (play due to mechanical precision)
(2) Related Parameter
Set the following parameter to use backlash compensation.
Backlash Compensation Direction
Set the direction in which to apply backlash compensation.
Pn230
Parameter n.
[Factory
0 setting] n. 1
Function
Compensates with a reference in the forward direction.
When Enabled Classification
After restart Setup
Compensates with a reference in the reverse direction.
Backlash Compensation Value
Set the amount of backlash compensation to add to the position reference.
The amount is set in increments of 0.1 reference unit. However, when the amount is converted to encoder pulses, it is rounded off at the decimal point.
Example: If Pn231 is set to 6,553.6 [reference unit] and the electronic gear ratio (Pn20E/Pn210) is set to 4/1, then the pulse equivalent is 6,553.6 × 4 = 26,214.4 [pulses].
⇒ The backlash compensation value will be 26,214 encoder pulses.
Pn231
Backlash compensation value
Setting Range
-500000 to 500000
Position
Setting Unit Factory Setting When Enabled
0.1 reference unit
0 Immediately
Classification
Setup
5.8 Additional Adjustment Function
• The backlash compensation value is restricted by the following formula. The specified compensation is not performed if this condition is not met.
Pn231 ≤
Pn210
Pn20E
×
Maximum motor speed [min -1 ]
60
× Encoder resolution × 0.00025
∗ For details on encoder resolution, refer to 8.3.5 Electronic Gear . With fully-closed loop control, substitute the number of external encoder pulses per motor revolution for “encoder resolution” in the formula above.
Example 1:
Assuming Pn20E = 4, Pn210 = 1, maximum motor speed = 6000 [min
-1
], encoder resolution = 1048576 (20 bits):
1/4 × 6000/60 × 1048576 × 0.00025 = 6553.6 [reference units]
⇒ The upper limit for the backlash compensation is 6553.6 [reference units].
Example 2:
When using the conditions Pn20E = 4, Pn210 = 1, maximum motor speed = 6000 [min
-1
], external encoder pitch count (Pn20A) = 500, JZDP-D00 -000 (signal resolution: 1/256):
1/4 × 6000/60 × (500 × 256) × 0.00025 = 800.0 [reference units]
⇒ The upper limit for the backlash compensation is 800.0 [reference units].
• Do not exceed the upper limit of the backlash compensation value. The upper limit of the backlash compensation value can be confirmed in Un031.
Backlash Compensation Time Constant
Set a time constant for a first order lag filter to use when adding the backlash compensation value (Pn231) to the position reference.
If you set Pn233 to 0, the first order lag filter is disabled.
Pn233
Un No.
Un030
Un031
Backlash compensation time constant
Setting Range
0 to 65535
Position
Setting Unit Factory Setting When Enabled
0.01 ms 0 Immediately
Displayed Information
The current backlash compensation value
Backlash compensation setting limit value
(4) Compensation Operation
This section describes the operation that is performed for backlash compensation.
Classification
Setup
Note: Changes to the set value are applied when there is no position reference input and the servomotor is stopped. The current operation is not affected if the set value is changed during servomotor operation.
(3) Related Monitor
The following monitoring parameters provide information on backlash compensation.
Unit
0.1 reference unit
0.1 reference unit
Note: The following figures are for when backlash compensation is applied for references in the forward direction
(Pn230.0 = 0). The following monitoring information is provided in the figures: TPOS (target position in the reference coordinate system), POS (reference position in the reference coordinate system), and APOS (feedback position in the machine coordinate system). The monitoring information includes the feedback position in machine coordinate system (APOS) and other feedback information. The backlash compensation value is subtracted from the feedback positions in the monitoring information, so it is not necessary for the host controller to consider the backlash compensation value.
5
5-65
5-66
5 Adjustments
5.8.6 Backlash Compensation Function
CAUTION
• The encoder output pulse will output the number of encoder pulses for which driving was actually performed, including the backlash compensation value. If using the encoder output pulse for position feedback at the host controller, must consider the backlash compensation value.
When Servo is ON
The backlash compensation value (Pn231) is added in the compensation direction when the servo is ON (i.e., the servomotor is powered) and a reference is input in the same direction as the backlash compensation direction (Pn230.0). If there is a reference input in the direction opposite to the backlash compensation direction, the backlash compensation value is not added (i.e., backlash compensation is not performed).
The relationship between APOS and the servomotor shaft position is as follows:
• If a reference is input in the compensation direction: APOS = Motor shaft position - Pn231
• If a reference is input in the direction opposite to the compensation direction: APOS = Motor shaft position
The following figure shows driving the servomotor in the forward direction from target position TPOS0 to
TPOS1 and then to TPOS2, and then returning from TPOS2 to TPOS1 and then to TPOS0.
Backlash compensation is applied when moving from TPOS0 to TPOS1, but not when moving from TPOS2 to
TPOS1.
Servo ON MECHA
If a reference is input in the compensation direction
POS
APOS
Machine axis
Target position
TPOS0
Travel distance 䋱
Target position
TPOS1
Travel distance 䋲
Target position
TPOS2
Pn231
Travel distance 䋱 Travel distance 䋲
Motor axis
Machine axis
Motor axis
Backlash (= Pn231)
If a reference is input in the direction opposite to the compensation direction
POS
APOS
Machine axis
Travel distance 䋱 Travel distance 䋲
Travel distance 䋱 Travel distance 䋲
Pn231
Motor axis
Machine axis
Motor axis
Backlash (= Pn231)
5.8 Additional Adjustment Function
When Servo is OFF
Backlash compensation is not applied when the servo is OFF (i.e., when the servomotor is not powered).
Therefore, the reference position POS moves by only the backlash compensation value.
The relationship between APOS and the servomotor shaft position is as follows:
• When servo is OFF: APOS = Servomotor shaft position
The following figure shows what happens when the servo is turned OFF after driving the servomotor in the forward direction from target position TPOS0 to TPOS1. Backlash compensation is not applied when the servo is OFF (i.e., the SERVOPACK manages the position data so that APOS and POS are the same).
Servo OFF MECHA
Target position
TPOS0
Target position
TPOS1
Travel distance
POS
APOS
Status with no backlash compensation POS = APOS
Machine axis
Pn231
Travel distance
Motor axis
Machine axis
Motor axis
Backlash 䋨 = Pn231 䋩
When There is Overtravel
When there is overtravel (i.e., when driving is prohibited due to an overtravel signal or software limit), the operation is the same as for When Servo is OFF , i.e., backlash compensation is not applied.
When Control is Changed
Backlash compensation is performed only for position control.
Backlash compensation is not applied if changing from position control to any other type of control.
Backlash compensation is applied in the same way as When Servo is ON if changing from any other type of control to position control.
When Safety Module Active Mode is Used
During an operation in active mode function, the operation is the same as for When Servo is OFF , i.e., backlash compensation is not applied.
5
5-67
5-68
5 Adjustments
5.8.6 Backlash Compensation Function
(5) Monitor Functions (Un Monitoring)
Un No.
Displayed Information
Un007 Input reference speed
Un008 Position error amount
Un00C Input reference counter
Un00D Feedback pulse counter
Un00E
Fully-closed feedback pulse counter
Un013 Feedback pulse counter
Unit min
-1
Reference unit
Reference unit
Encoder pulse
External encoder resolution
Reference unit
Specification
Indicates the input reference speed before backlash compensation.
Displays the position error with respect to the position reference after backlash compensation.
Displays the input reference counter before backlash compensation.
Displays the pulse count of the actually driven motor encoder.
Displays the pulse count of the actually driven external encoder.
Displays the pulse count of the actually driven encoder in reference units.
(6) MECHATROLINK Monitor Information
This section describes the information that is set for the MECHATROLINK monitoring information (Monitor
1, Monitor 2, Monitor 3, and Monitor 4) and the backlash compensation operation.
Monitor
Code
0
1
2
3
4
5
6
E
F
Designation
POS
Meaning
Reference position in the reference coordinate system (after the position reference filter)
MPOS Reference position
PERR Position error
APOS
LPOS
IPOS
TPOS
OMN1
OMN2
Feedback position in the machine coordinate system
Feedback latch position in the machine coordinate system
Reference position in the reference coordinate system (before the position reference filter)
Target position in the reference coordinate system
Option monitor 1
(selected with Pn824)
Option monitor 2
(selected with Pn825)
Unit Remarks
Reference unit
Reference unit
Reference unit
Reference unit
Reference unit
Reference unit
Reference unit
–
–
–
–
Feedback position with the backlash compensation subtracted
Feedback position with the backlash compensation subtracted
–
–
–
– –
5.8 Additional Adjustment Function
Parameters Monitor Information
0003H Position error (lower 32 bits)
Pn824
Pn825
0004H Position error (upper 32 bits)
000AH Encoder count (lower 32 bits)
000BH Encoder count (upper 32 bits)
000CH FPG count (lower 32 bits)
000DH FPG count (upper 32 bits)
0017H Un007: Input reference speed
0018H Un008: Position error amount
001CH Un00C: Input reference counter
001DH Un00D: Feedback pulse counter
001EH
Un00E: Fully-closed feedback pulse counter
0080H
Previous value of latched feedback position (LPOS)
Related Monitoring Diagrams
Output Unit
Reference unit
Reference unit
Reference unit
Reference unit
Reference unit
Reference unit min
-1
Reference unit
Reference unit
Encoder pulse
External encoder resolution
Encoder pulse
Remarks
–
–
Count value of the actually driven motor encoder
Count value of the actually driven external encoder
Same as monitor display Un007
Same as monitor display Un008
Same as monitor display Un00C
Same as monitor display Un00D
Same as monitor display Un00E
Feedback position with the backlash compensation subtracted
MECHA
[M]: IPOS
[M]: TPOS
[M]: MPOS
([M]: POS)
Position reference
Position reference filter
Speed conversation
Electronic gear
[U][M]: Un00C
[A][T]: Position reference speed
[U][M]: Un007
Backlash compensation function
㧗
[A][T]: Speed feedforward
[A][T]: Position amplifier error
㧙
Feedforward
Error counter
Kp
<Legend symbols>
[A]: Analog monitoring
[U]: Monitor display
(Un monitoring)
[O]: Outpur signal
[T]: Trace data object
[M]: MECHATROLINK
monitor information
㧗 㧗
Speed/ current loop
㧹 Load
Speed conversation
ENC
External
ENC
[M]: PERR
Error counter
㧗
㧙
㧗 㧙
Error counter
[U]: Un013
㧝
Electronic gear
[A][T][M]: Position error
[U][M]: Un008
Output signal processing
[A][O][T]: Positioning completed
[A][T]: Completion of position reference
[O][T]: Position near [M]: APOS
[M]: Previous value for LPOS
[M]: LPOS
㧝
Electronic gear
㧝
Electronic gear
Latch signal
Backlash compensation function
[U][M]: Un00D
[U][M]: Un00E
[M]: PG count
[M]: FPG count
5
5-69
5-70
5 Adjustments
5.8.7 Position Integral
5.8.7
Position Integral
The position integral is the integral function of the position loop. It is used for the electronic cams and electronic shafts when using the SERVOPACK with Yaskawa MP900/2000 machine controllers.
Pn11F
Position Integral Time Constant
Setting Range
0 to 50000
Setting Unit
0.1 ms
Factory Setting
0
Position
When Enabled
Immediately
Classification
Tuning
5.9 Compatible Adjustment Function
5.9
Compatible Adjustment Function
The Σ -V large-capacity SERVOPACKs have adjustment functions as explained in sections 5.1
to 5.8
to make machine adjustments.
This section explains compatible functions provided by earlier models, such as the Σ -II large-capacity SER-
VOPACK.
5.9.1
Feedforward Reference
This function applies feedforward compensation to position control and shortens positioning time.
Differential
Pn109
Feedforward Gain
MECHA
Position reference
Pn10A
Feedforward Filter
Time Constant
+ + +
Position loop gain (Kp)
-
Feedback pulse
Feedforward Gain
Setting Range
0 to 100
Position
When Enabled
Immediately
Classification
Pn109
Setting Unit
1%
Factory Setting
0 Tuning
Feedforward Filter Time Constant
Position
Setting Unit
0.01 ms
Factory Setting
0
When Enabled
Immediately
Classification
Pn10A
Setting Range
0 to 6400 Tuning
Note: Too high value may cause the machine to vibrate. For ordinary machines, set 80% or less in this parameter.
5
5-71
5-72
5 Adjustments
5.9.2 Mode Switch (P/PI Switching)
5.9.2
Mode Switch (P/PI Switching)
The mode switch automatically switches between proportional and PI control. Set the switching condition with Pn10B.0 and set the level of detection points with Pn10C, Pn10D, Pn10E, and Pn10F.
Overshooting caused by acceleration and deceleration can be suppressed and the settling time can be reduced by setting the switching condition and detection points.
With Mode Switch
Motor speed
Without Mode Switch
Overshoot
Actual servomotor operation
Motor speed
Reference
Overshoot
Settling time
Time
Settling time
Time
(1) Related Parameters
Select the switching condition of the mode switch with Pn10B.0.
Parameter Mode Switch Selection
Pn10B n.
0
[Factory setting] n.
n.
n.
n.
1
2
3
4
Uses an internal torque reference level for the switching conditions.
Uses a speed reference level for the switching conditions.
Uses an acceleration level for the switching conditions.
Uses a position error level for the switching conditions.
Does not use mode switch function.
Parameter
Containing
Detection
Point Setting
When
Enabled
Classification
Pn10C
Pn10D
Pn10E
Pn10F
−
Immediately
Setup
Parameters to Set the Level of Detection Points
Pn10C
Mode Switch (Torque Reference)
Setting Range
0 to 800
Setting Unit
1%
Pn10D
Mode Switch (Speed Reference)
Setting Range
0 to 10000
Setting Unit
1 min
-1
Pn10E
Mode Switch (Acceleration)
Setting Range
0 to 30000
Setting Unit
1 min
-1
/s
Pn10F
Mode Switch (Position Error)
Setting Range
0 to 10000
Setting Unit
1 reference unit
Speed
Factory Setting
200
Speed
Factory Setting
0
Speed
Factory Setting
0
Factory Setting
0
Position
When Enabled
Immediately
Position
When Enabled
Immediately
Position
When Enabled
Immediately
Position
When Enabled
Immediately
Classification
Tuning
Classification
Tuning
Classification
Tuning
Classification
Tuning
5.9 Compatible Adjustment Function
(2) Operating Examples for Different Switching Conditions
Using the Torque Reference [Factory Setting]
With this setting, the speed loop is switched to P control when the value of torque reference input exceeds the torque set in Pn10C. The factory setting for the torque reference detection point is 200% of the rated torque.
Speed
Speed reference
Motor speed Rotation
Time
+Pn10C
Torque
Reference
0
- Pn10C
Torque reference
PI P PI Control P PI Control
Using the Speed Reference
With this setting, the speed loop is switched to P control when the value of speed reference input exceeds the speed set in Pn10D.
Speed
Speed reference
Motor speed
Rotation
Pn10D
PI P Control
Time
PI Control
Using Acceleration
With this setting, the speed loop is switched to P control when the speed reference exceeds the acceleration set in Pn10E.
Speed
Speed reference
Motor speed
Rotation
Time
Motor acceleration
+Pn10E
Acceleration 0
- Pn10E
PI P PI Control P PI Control
Using the Position Error
With this setting, the speed loop is switched to P control when the position error exceeds the value set in
Pn10F.
This setting is effective with position control only.
Speed reference
Speed
Motor speed
Time
Position error
Pn10F
PI P Control PI Control
5
5-73
5-74
5 Adjustments
5.9.3 Torque Reference Filter
5.9.3
Torque Reference Filter
As shown in the following diagram, the torque reference filter contains first order lag filter and notch filters arrayed in series, and each filter operates independently. The notch filters can be enabled and disabled with the
Pn408.
Rotation
Torque Related
Function Switch
Pn408
Torque reference before filtering
Torque
Reference
Filter
(Pn401)
*
2nd
Torque
Reference
Filter
(Pn40F,
Pn410)
1st Notch
Filter
(Pn409,
Pn40A, and Pn40B)
2nd
Notch
Filter
(Pn40C,
Pn40D, and
Pn40E)
Torque reference after filtering
First order lag filter Second order lag filter
Notch filter Notch filter
* The 2nd torque reference filter is enabled when Pn40F is set to a value less than
5000 and disabled when Pn40F is set to 5000 (factory setting).
(1) Torque Reference Filter
If you suspect that machine vibration is being caused by the servo drive, try adjusting the filter time constants with Pn401. This may stop the vibration. The lower the value, the better the response will be, but there may be a limit that depends on the machine conditions.
Pn401
Torque Reference Filter Time Constant
Setting Range
0 to 65535
Setting Unit
0.01 ms
Speed Position Torque
Factory Setting
100
When Enabled
Immediately
Classification
Tuning
Torque
Reference Filter Setting Guide
Use the speed loop gain (Pn100 [Hz]) and the torque filter time constant (Pn401 [ms]) to set the torque reference filter.
Adjusted value for stable control: Pn401 [ms] ≤ 1000/ (2 π × Pn100 [Hz] × 4)
Critical gains: Pn401 [ms] < 1000/ (2 π × Pn100 [Hz] × 1)
Pn40F
Pn410
2nd Step 2nd Torque Reference Filter
Frequency
Setting Range
100 to 5000
Setting Unit
1 Hz
2nd Step 2nd Torque Reference Filter
Q Value
Setting Range
50 to 100
Setting Unit
0.01
∗ The filter is disabled if 5000 is set.
Speed Position Torque
Factory Setting
5000
*
When Enabled
Immediately
Speed Position Torque
Factory Setting
50
When Enabled
Immediately
Classification
Tuning
Classification
Tuning
5.9 Compatible Adjustment Function
(2) Notch Filter
The notch filter can eliminate specific frequency elements generated by the vibration of sources such as resonance of the shaft of a ball screw. The notch filter puts a notch in the gain curve at the specific vibration frequency. The frequency characteristics near the notch can be reduced or removed with this filter. A higher Q value produces a sharper notch and phase delay.
Q value = 1.0
Notch Filter
Q value = 0.7
Notch Filter
100
0
Gain
(db)
-100
-200
-300
10
2
10
3
Frequency (Hz)
Notch Filter
10
4
0
-100
Phase
(deg)
-200
-300
-400
10
2
10
3
Frequency (Hz)
10
4
The notch filter can be enabled or disabled with Pn408.
100
0
Gain
(db)
-100
-200
-300
10
2
0
-100
Phase
(deg)
-200
-300
-400
10
2
Pn408
Parameter n.
0
[Factory setting] n.
1 n. 0
[Factory setting] n. 1
Meaning
Disables 1st notch filter.
Enables 1st notch filter.
Disables 2nd notch filter.
Enables 2nd notch filter.
Set the machine's vibration frequency as a parameter of the notch filter.
10
3
Frequency (Hz)
Notch Filter
10
3
Frequency (Hz)
10
4
10
4
When Enabled Classification
Immediately Setup
Pn409
Pn40A
Pn40B
Pn40C
Pn40D
1st Notch Filter Frequency
Setting Range
50 to 5000
1st Notch Filter Q Value
Setting Unit
1 Hz
Setting Range
50 to 1000
1st Notch Filter Depth
Setting Unit
0.01
Setting Range
0 to 1000
Setting Unit
2nd Notch Filter Frequency
0.001
Setting Range
50 to 5000
2nd Notch Filter Q Value
Setting Unit
1 Hz
Setting Range
50 to 1000
Setting Unit
0.01
Speed Position Torque
Factory Setting
5000
When Enabled
Immediately
Speed Position Torque
Factory Setting
70
When Enabled
Immediately
Speed Position Torque
Factory Setting
0
When Enabled
Immediately
Speed Position Torque
Factory Setting
5000
When Enabled
Immediately
Speed Position Torque
Factory Setting
70
When Enabled
Immediately
Classification
Tuning
Classification
Tuning
Classification
Tuning
Classification
Tuning
Classification
Tuning
5
5-75
5-76
5 Adjustments
5.9.3 Torque Reference Filter
Pn40E
2nd Notch Filter Depth
Setting Range
0 to 1000
Setting Unit
0.001
Speed Position Torque
Factory Setting
0
When Enabled
Immediately
(cont’d)
Classification
Tuning
• Sufficient precautions must be taken when setting the notch filter frequencies. Do not set the notch filter frequencies (Pn409 or Pn40C) that is close to the speed loop’s response frequency. Set the frequencies at least four times higher than the speed loop’s response frequency. Setting the notch filter frequency too close to the response frequency may cause vibration and damage the machine.
• Change the notch filter frequencies (Pn409 or Pn40C) only when the servomotor is stopped. Vibration may occur if the notch filter frequency is changed when the servomotor is rotating.
Utility Functions (Fn
6
)
6.1 List of Utility Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
6.2 Alarm History Display (Fn000) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
6.3 JOG Operation (Fn002) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
6.4 Origin Search (Fn003) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
6.5 Program JOG Operation (Fn004) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8
6.6 Initializing Parameter Settings (Fn005) . . . . . . . . . . . . . . . . . . . . . . . . . . 6-12
6.7 Clearing Alarm History (Fn006) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-13
6.8 Offset Adjustment of Analog Monitor Output (Fn00C) . . . . . . . . . . . . . . 6-14
6.9 Gain Adjustment of Analog Monitor Output (Fn00D) . . . . . . . . . . . . . . . 6-16
6.10 Automatic Offset-Signal Adjustment of the Motor Current
Detection Signal (Fn00E) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-18
6.11 Manual Offset-Signal Adjustment of the Motor Current
Detection Signal (Fn00F) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-19
6.12 Write Prohibited Setting (Fn010) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-21
6.13 Servomotor Model Display (Fn011) . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-23
6.14 Software Version Display (Fn012) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-24
6.15 Resetting Configuration Errors in Option Modules (Fn014) . . . . . . . . . 6-25
6.16 Vibration Detection Level Initialization (Fn01B) . . . . . . . . . . . . . . . . . . 6-26
6.17 Display of SERVOPACK and Servomotor ID (Fn01E) . . . . . . . . . . . . . 6-28
6.18 Display of Servomotor ID in Feedback Option Module (Fn01F) . . . . . . 6-30
6.19 Origin Setting (Fn020) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-31
6.20 Software Reset (Fn030) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-32
6.21 EasyFFT (Fn206) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-33
6.22 Online Vibration Monitor (Fn207) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-37
6
6-1
6-2
6 Utility Functions (Fn )
6.1
List of Utility Functions
Utility functions are used to execute the functions related to servomotor operation and adjustment.
Each utility function has a number starting with Fn.
The following table lists the utility functions and reference section.
Function
No.
Fn00F
Fn010
Fn011
Fn012
Fn013
Fn014
Fn01B
Fn01E
Fn01F
Fn020
Fn030
Fn200
Fn201
Fn202
Fn000
Fn002
Fn003
Fn004
Fn005
Fn006
Fn008
Fn00C
Fn00D
Fn00E
Fn203
Fn204
Fn205
Fn206
Fn207
Function
Alarm history display
JOG operation
Origin search
Program JOG operation
Initializing parameter settings
Clearing alarm history
Absolute encoder multiturn reset and encoder alarm reset
Offset adjustment of analog monitor output
Gain adjustment of analog monitor output
Automatic offset-signal adjustment of the motor current detection signal
Manual offset-signal adjustment of the motor current detection signal
Write prohibited setting
Servomotor model display
Software version display
Multiturn limit value setting change when a multiturn limit disagreement alarm occurs
Resetting configuration error in option modules
Vibration detection level initialization
Display of SERVOPACK and servomotor ID
Display of servomotor ID in feedback option module
Origin setting
Software reset
Tuning-less levels setting
Advanced autotuning
Advanced autotuning by reference
One-parameter tuning
Anti-resonance control adjustment function
Vibration suppression function
EasyFFT
Online vibration monitor
Reference
Section
6.15
6.16
6.17
6.18
6.19
6.20
6.10
6.11
6.12
6.13
6.14
4.7.7
5.2.2
5.3.2
5.4.2
5.5.2
5.6.2
5.7.2
6.21
6.22
6.2
6.3
6.4
6.5
6.6
6.7
4.7.4
6.8
6.9
Note: Execute the utility function with either a digital operator or SigmaWin+. If they are used together, "no_oP" or "NO-
OP" will be displayed when the utility function is executed.
6.2 Alarm History Display (Fn000)
6.2
Alarm History Display (Fn000)
This function displays the last ten alarms that have occurred in the servo drive.
The latest ten alarm numbers and time stamps * can be checked.
∗ Time Stamps
A function that measures the ON times of the control power supply and main circuit power supply in 100-ms units and displays the total operating time when an alarm occurs. The time stamp operates around the clock for approximately 13 years.
<Example of Time Stamps>
If 36000 is displayed,
3600000 [ms] = 3600 [s] = 60 [min] = 1 [h]
Therefore, the total number of operating hours is 1 hour.
(1) Preparation
There are no tasks that must be performed before displaying the alarm history.
(2) Operating Procedure
Use the following procedure.
Step
1
Display after Operation
B B − F U N C T I O N −
F n 2 0 7 : V − M o n i t o r
F n 0 0 0 : A l m H i s t o r y
F n 0 0 2 : J O G
F n 0 0 3 : Z − S e a r c h
Keys Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn000.
Key to move through the list and
2
A . D 0 0 − A L A R M −
0 : D 0 0 0 0 0 0 1 2 0 7 1 9 6
1 : 7 2 0 0 0 0 0 0 0 3 2 6 5 1
2 : 5 1 1 0 0 0 0 0 0 0 9 0 4 3
3 : − − −
Press the Key. The display changes to the Fn000 execution display.
3
A . D 0 0 − A L A R M −
1 : 7 2 0 0 0 0 0 0 0 3 2 6 5 1
2 : 5 1 1 0 0 0 0 0 0 0 9 0 4 3
3 : − − −
4 :
− − −
Time stamp
Alarm no.
Alarm history no.
0: Latest
9: Oldest
Press the or Key to scroll through the alarm history. The alarm history can be viewed.
4
B B − F U N C T I O N −
F n 2 0 7 : V − M o n i t o r
F n 0 0 0 : A l m H i s t o r y
F n 0 0 2 : J O G
F n 0 0 3 : Z − S e a r c h
Press the Key.
The display returns to the main menu of the utility function.
Note:
• If the same alarm occurs after more than one hour, the alarm will be saved. If it occurs in less than one hour, it will not be saved.
• The display " .---" means no alarm occurs.
• Delete the alarm history using the parameter Fn006. The alarm history is not cleared on alarm reset or when the main circuit power supply to the SERVOPACK and converter is turned OFF.
6
6-3
6-4
6 Utility Functions (Fn )
6.3
JOG Operation (Fn002)
JOG operation is used to check the operation of the servomotor under speed control without connecting the
SERVOPACK to the host controller.
CAUTION
• While the SERVOPACK is in JOG operation, the overtravel function will be disabled. Consider the operating range of the machine when performing JOG operation for the SERVOPACK.
(1) Preparation
The following conditions must be met to perform a jog operation.
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
• The main circuit power supply must be ON.
• All alarms must be cleared.
• The hardwire baseblock (HWBB) must be disabled.
• The servomotor power must be OFF.
• The JOG speed must be set considering the operating range of the machine.
Set the jog speed in Pn304.
Pn304
Jog Speed
Setting Range
0 to 10000
Setting Unit
1 min
-1
Speed
Factory Setting
Position Torque
When Enabled
500 Immediately
Classification
Setup
(2) Operating Procedure
Use the following procedure. The following example is for when Pn000.0 is set to 0 (CCW is forward direction) as the rotation direction of the motor.
Step Display after Operation Keys
1
B B − F U N C T I O N −
F n 0 0 0 : A l m H i s t o r y
F n 0 0 2 : J O G
F n 0 0 3 : Z − S e a r c h
F n 0 0 4 : P r o g r a m J O G
Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn002.
Key to move through the list and
2
B B − J O G −
P n 3 0 4 = 0 0 5 0 0
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0
Press the Key. The display changes to the Fn002 execution display.
3
4
5
6
B B − J O G −
P n 3 0 4 = 0 0 5 0 0
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0
B B − J O G −
P n 3 0 4 = 0 1 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0
B B − J O G −
P n 3 0 4 = 0 1 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0
R U N − J O G −
P n 3 0 4 = 0 1 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0
Press the Key.
The cursor moves to the setting side (the right side) of
Pn304 (JOG speed).
Press the or Key and the or min
-1
.
Key to set the JOG speed (Pn304) to 1000
Press the Key.
The setting value is entered, and the cursor moves to the parameter number side (the left side).
Press the Key.
The status display changes from "BB" to "RUN", and the servomotor power turns ON.
6.3 JOG Operation (Fn002)
Step Display after Operation Keys
(cont’d)
Operation
The servomotor will rotate at the present speed set in
Pn304 while the Key (for forward rotation) or
Key (for reverse rotation) is pressed.
7
R U N − J O G −
P n 3 0 4 = 0 1 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0
Forward
8
B B − J O G −
P n 3 0 4 = 0 1 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0
Reverse
After having confirmed the correct motion of servomotor, press the Key.
The status display changes from "RUN" to "BB", and the servomotor power turns OFF.
9
B B − F U N C T I O N −
F n 0 0 0 : A l m H i s t o r y
F n 0 0 2 : J O G
F n 0 0 3 : Z
−
S e a r c h
F n 0 0 4 : P r o g r a m J O G
Press the Key.
The display returns to the main menu of the utility function.
10 To enable the change in the setting, turn the power OFF and ON again.
6
6-5
6-6
6 Utility Functions (Fn )
6.4
Origin Search (Fn003)
The origin search is designed to position the origin pulse position of the incremental encoder (phase C) and to clamp at the position.
CAUTION
• Perform origin searches without connecting the coupling.
The forward run prohibited (P-OT) and reverse run prohibited (N-OT) signals are not effective in origin search mode.
This function is used when the motor shaft needs to be aligned to the machine.
Motor speed at the time of execution: 60 min
-1
Machine
Servomotor Rotation
For aligning the motor shaft to the machine
(1) Preparation
The following conditions must be met to perform the origin search.
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
• The main circuit power supply must be ON.
• All alarms must be cleared.
• The hardwire baseblock (HWBB) must be disabled.
• The servomotor power must be OFF.
6.4 Origin Search (Fn003)
(2) Operating Procedure
Use the following procedure.
Step
1
Display after Operation
B B − F U N C T I O N −
F n 0 0 2 : J O G
F n 0 0 3 : Z − S e a r c h
F n 0 0 4 : P r o g r a m J O G
F n 0 0 5 : P r m I n i t
Keys Operation
Press the ity function.
Key to view the main menu for the util-
Use the or select Fn003.
Key to move through the list and
2
B B − Z − S e a r c h −
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 3 = 0 0 0 0 0 0 0 0 7 7 4
U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0
Press the Key. The display changes to the Fn003 execution display.
3
4
5
R U N − Z − S e a r c h −
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 3 = 0 0 0 0 0 0 0 0 7 7 4
U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0
R U N
−
C o m p l e t e
−
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 3 = 0 0 0 0 0 0 0 0 0 0 0
U n 0 0 D = 0 0 0 0 0 0 0 1 D 5 8
B B − Z − S e a r c h −
U n 0 0 0 = 0 0 0 0 0 0
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 3 = 0 0 0 0 0 0 0 0 0 0 0
U n 0 0 D = 0 0 0 0 0 0 0 1 D 5 8
Press the Key.
The status display changes from "BB" to "RUN", and the servomotor power turns ON.
Note: If the servomotor is already at the zero position,
"-Complete-" is displayed.
Pressing the Key will rotate the servomotor in the forward direction. Pressing the Key will rotate the servomotor in the reverse direction. The rotation direction of the servomotor changes according to the setting of Pn000.0 as shown in the following table.
Parameter key key
Pn000 n.
n.
0
1
CCW
CW
CW
CCW
Note: Direction when viewed from the load of the servomotor.
Press the or Key until the servomotor stops.
If the origin search completed normally, "-Complete-" is displayed on the right top on the screen.
When the origin search is completed, press the
Key.
The status display changes from "RUN" to "BB", and the servomotor turns OFF. The display "-Complete-" changes to "-Z-Search-."
6
B B − F U N C T I O N −
F n 0 0 2 : J O G
F n 0 0 3 : Z − S e a r c h
F n 0 0 4 : P r o g r a m J O G
F n 0 0 5 : P r m I n i t
Press the Key.
The display returns to the main menu of the utility function.
7 To enable the change in the setting, turn the power OFF and ON again.
6
6-7
6-8
6 Utility Functions (Fn )
6.5
Program JOG Operation (Fn004)
The program JOG operation is a utility function, that allows continuous operation determined by the preset operation pattern, movement distance, movement speed, acceleration/deceleration time, waiting time, and number of times of movement.
This function can be used to move the servomotor without it having to be connected to a host controller for the machine as a trial operation in JOG operation mode. Program JOG operation can be used to confirm the operation and for simple positioning operations.
(1) Preparation
The following conditions must be met to perform the program JOG operation.
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
• The main circuit power supply must be ON.
• All alarms must be cleared.
• The hardwire baseblock (HWBB) must be disabled.
• The servomotor power must be OFF.
• The travel distance and speed must be set correctly considering the machine operation range and safe operation speed.
• There must be no overtravel.
(2) Additional Information
• The functions that are applicable for position control, such as position reference filter, can be used.
• The overtravel function is enabled in this function.
(3) Program JOG Operation Patterns
The following describes an example of program JOG operation pattern. The following example is given when the rotating direction of the servomotor is set as Pn000.0 = 0 (Forward rotation by forward reference).
Pn530.0 = 0
(Waiting time Pn535 → Forward movement Pn531) × Number of movements Pn536
Number of times of movement Pn536
Speed
Diagram
Movement speed
Pn533
Pn531
Movement distance
At zero speed
Press the
Key.
Waiting time
Pn535
Accel/Decel time
Pn534
Waiting time
Pn535
Pn531
Movement distance
Waiting time
Pn535
Pn531
Movement distance
Servomotor
Run Status
(Stop) (Forward) (Stop) (Forward) (Stop) (Forward)
Note: When Pn536 (number of times of program JOG movement) is set to 0, infinite time operation is enabled. To stop infinite time operation, press the JOG/SVON Key to turn OFF the servomotor power.
6.5 Program JOG Operation (Fn004)
Pn530.0 = 1
(Waiting time Pn535 → Reverse movement Pn531) × Number of movements Pn536
Number of movements Pn536
Speed
Diagram
At zero speed
Movement speed
Pn533
Pn531
Movement distance
Pn531
Movement distance
Pn531
Movement distance
Press the
Key.
Waiting time
Accel/Decel time
Pn534
Pn535
Waiting time
Pn535
Waiting time
Pn535
Servomotor
Run Status
(Stop) (Reverse) (Stop) (Reverse) (Stop) (Reverse)
Note: When Pn536 (Number of Times of Program JOG Movement) is set to 0, infinite time operation is enabled. To stop infinite time operation, press the JOG/SVON Key to turn the servomotor power OFF.
Pn530.0 = 2
(Waiting time Pn535 → Forward movement Pn531) × Number of movements Pn536
(Waiting time Pn535 → Reverse movement Pn531) × Number of movements Pn536
Number of movements Pn536 Number of movements Pn536
Speed
Diagram
Movement speed
Pn533
Pn531
Movement distance
At zero speed
Press the
Key.
Waiting time
Pn535
Accel/Decel time
Pn534
Waiting time
Pn535
Pn531
Movement distance
Accel/Decel time
Waiting time
Pn534
Pn535
Waiting time
Pn535
Pn531
Movement distance
Pn531
Movement distance
Servomotor
Run Status
(Stop) (Forward) (Stop) (Forward)
Note: When Pn530.0 is set to 2, infinite time operation is disabled.
(Stop) (Reverse) (Stop) (Reverse)
Pn530.0 = 3
(Waiting time Pn535 → Reverse movement Pn531) × Number of movements Pn536
(Waiting time Pn535 → Forward movement Pn531) × Number of movements Pn536
Number of movements Pn536 Number of movements Pn536
Movement speed
Pn533
Speed
Diagram
Press the
Waiting time
Pn535
Accel/Decel time
Pn534 Waiting time
Pn535
Key.
At zero speed
Pn531
Movement distance
Pn531
Movement distance
Waiting time
Pn535
Pn531
Movement distance
Accel/Decel time
Pn533
Pn534
Movement speed
Waiting time
Pn535
Pn531
Movement distance
Servomotor
Run Status
(Stop) (Reverse) (Stop) (Reverse)
Note: When Pn530.0 is set to 3, infinite time operation is disabled.
(Stop) (Forward) (Stop) (Forward)
Movement speed
Pn533
6
6-9
6-10
6 Utility Functions (Fn )
Pn530.0 = 4
(Waiting time Pn535 → Forward movement Pn531 → Waiting time Pn535 → Reserve movement Pn531)
× Number of movements Pn536
Number of movements Pn536
Speed
Diagram
Pn531
Movement distance
At zero speed
Press the
Key.
Waiting time
Pn535
Waiting time
Accel/Decel time
Pn534
Pn535
Movement speed
Pn533
Pn531
Movement distance
Pn533
Movement speed
Servomotor
Run Status
(Stop) (Forward) (Stop) (Reverse) (Stop)
Note: When Pn536 (number of times of program JOG movement) is set to 0, infinite time operation is enabled. To stop infinite time operation, press the JOG/SVON Key to turn OFF the servomotor power.
Pn530.0 = 5
(Waiting time Pn535 → Reverse movement Pn531 → Waiting time Pn535 → Forward movement Pn531)
× Number of movements Pn536
Number of movements Pn536
Speed
Diagram
Waiting time
Pn535
Press the
Key.
Accel/Decel time
Pn534
Waiting time
Pn535
At zero speed
Pn531
Movement distance
Movement speed
Pn533
Pn531
Movement distance
Pn533
Movement speed
Servomotor
Run Status
(Stop) (Reverse) (Stop) (Forward) (Stop)
Note: When Pn536 (number of times of program JOG movement) is set to 0, infinite time operation is enabled. To stop infinite time operation, press the JOG/SVON Key to turn the servomotor power OFF.
(4) Related Parameters
The following parameters set the program JOG operation pattern. Do not change the settings while the program JOG operation is being executed.
Pn530
Program JOG Operation Related Switch
Setting Range
0000 to 0005
Setting Unit
− 0000
Speed
Factory Setting
Position Torque
When Enabled
Immediately
Pn531
Program JOG Movement Distance
Setting Range
1 to 1073741824
Setting Unit
1 reference unit
Speed
Factory Setting
32768
Position Torque
When Enabled
Immediately
Classification
Setup
Classification
Setup
6.5 Program JOG Operation (Fn004)
(cont’d)
Pn533
Pn534
Pn535
Pn536
Program JOG Movement Speed
Setting Range Setting Unit
Speed
Factory Setting
Position Torque
When Enabled
1 to 10000 1 min
-1 500 Immediately
Program JOG Acceleration/Deceleration Time
Speed Position Torque
Setting Range
2 to 10000
Setting Unit
1 ms
Factory Setting
100
When Enabled
Immediately
Program JOG Waiting Time
Speed Position Torque
Setting Range
0 to 10000
Setting Unit
1 ms
Factory Setting
100
When Enabled
Immediately
Number of Times of Program JOG Movement
Speed Position Torque
Setting Range
0 to 1000
Setting Unit
1 time
Factory Setting
1
When Enabled
Immediately
Classification
Setup
Classification
Setup
Classification
Setup
Classification
Setup
(5) Operating Procedure
Use the following procedure to perform the program JOG operation after setting a program JOG operation pattern.
Step Display after Operation Keys Operation
1
B B − F U N C T I O N −
F n 0 0 3 : Z − S e a r c h
F n 0 0 4 : P r o g r a m J O G
F n 0 0 5 : P r m I n i t
F n 0 0 6 : A l m H i s t C l r
Press the Key to view the main menu for the utility function.
Use the or select Fn004.
Key to move through the list and
2
B B − P R G J O G −
P n 5 3 1 = 0 0 0 3 2 7 6 8
P n 5 3 3 = 0 0 5 0 0
P n 5 3 4 = 0 0 1 0 0
P n 5 3 6 = 0 0 0 1 0
Press the Key. The display changes to the Fn004 execution display.
3
*
B B − P R G J O G −
P n 5 3 1 = 0 0 0 3 2 7 6 8
P n 5 3 3 = 0 0 5 0 0
P n 5 3 4 = 0 0 1 0 0
P n 5 3 6 = 0 0 0 1 0
Confirm that the parameters have been set.
Press the Key to view Pn530.
Press the Key to view the parameters in the following order: Pn530 → Pn531 → Pn533 → Pn534 →
Pn535 → Pn536.
4
R U N − P R G J O G −
P n 5 3 1 = 0 0 0 3 2 7 6 8
P n 5 3 3 = 0 0 5 0 0
P n 5 3 4 = 0 0 1 0 0
P n 5 3 6 = 0 0 0 1 0
Press the Key.
The status display changes from "BB" to "RUN", and the servomotor power turns ON.
5
6
R U N − P R G J O G −
P n 5 3 1 = 0 0 0 3 2 7 6 8
P n 5 3 3 = 0 0 5 0 0
P n 5 3 4 = 0 0 1 0 0
P n 5 3 6 = 0 0 0 1 0
R U N − P R G J O G −
P n 5 3 1 = 0 0 0 3 2 7 6 8
P n 5 3 3 = 0 0 5 0 0
P n 5 3 4 = 0 0 1 0 0
P n 5 3 6 = 0 0 0 1 0
Press the (forward movement start) or
(reverse movement start) Key according to the first movement direction of the preset operation pattern.
The servomotor starts moving after the preset waiting time in Pn535.
Note: Pressing the Key again changes the status to "BB" (baseblocked status) and stops movement even during operation.
When the set program JOG operation movement is completed, "END" is displayed for one second, and then "RUN" is displayed.
Press the Key. The servomotor becomes baseblocked status. The display returns to the main menu of the utility function.
7 To enable the change in the setting, turn the power OFF and ON again.
∗ The settings can be changed for a parameter.
6
6-11
6-12
6 Utility Functions (Fn )
6.6
Initializing Parameter Settings (Fn005)
This function is used when returning to the factory settings after changing parameter settings.
• Be sure to initialize the parameter settings while the servomotor power is OFF .
• After initialization, turn OFF the power supply and then turn ON again to validate the settings.
Note: Any value adjusted with Fn00C, Fn00D, Fn00E, and Fn00F cannot be initialized by Fn005.
(1) Preparation
The following conditions must be met to initialize the parameter values.
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
• The servomotor power must be OFF.
(2) Operating Procedure
Use the following procedure.
Step
1
Display after Operation
B B − F U N C T I O N −
F n 0 0 4 : P r o g r a m J O G
F n 0 0 5 : P r m I n i t
F n 0 0 6 : A l m H i s t C l r
F n 0 0 8 : M t u r n C l r
2
B B
P a r a m e t e r l n i t
S t a r t : [ D A T A ]
R e t u r n : [ S E T ]
Keys
Press the
Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn005.
Key to move through the list and
Key. The display changes to the Fn005 execution display.
3
B B
P a r a m e t e r l n i t
S t a r t : [ D A T A ]
R e t u r n : [ S E T ]
Press the Key to initialize parameters.
During initialization, "Parameter Init" is flashing in the display.
After the initialization is completed, "Parameter Init" stops flashing and the status display changes as follows: "BB" to "DONE" to "BB."
Note: Press the Key not to initialize parameters.
The display returns to the main menu of the utility function.
4 To enable the change in the setting, turn the power OFF and ON again.
6.7 Clearing Alarm History (Fn006)
6.7
Clearing Alarm History (Fn006)
The clear alarm history function deletes all of the alarm history recorded in the SERVOPACK.
Note: The alarm history is not deleted when the alarm reset is executed or the main circuit power supply of the SERVO-
PACK is turned OFF.
(1) Preparation
The follow conditions must be met to clear the alarm history.
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
(2) Operating Procedure
Use the following procedure.
Keys Step
1
Display after Operation
B B − F U N C T I O N −
F n 0 0 5 : P r m I n i t
F n 0 0 6 : A l m H i s t C l r
F n 0 0 8 : M t u r n C l r
F n 0 0 9 : R e f A d j
2
B B
A l a r m H i s t o r y
D a t a C l e a r
S t a r t : [ D A T A ]
R e t u r n : [ S E T ]
3
B B
A l a r m H i s t o r y
D a t a C l e a r
S t a r t : [ D A T A ]
R e t u r n : [ S E T ]
Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn006.
Key to move through the list and
Press the Key. The display changes to the Fn006 execution display.
Press the Key to clear the alarm history.
While clearing the data, "DONE" is displayed in the status display. After the data has been successfully cleared, "BB" is displayed.
Note: Press the Key not to clear the alarm history. The display returns to the main menu of the utility function.
6
6-13
6 Utility Functions (Fn )
6.8
Offset Adjustment of Analog Monitor Output (Fn00C)
This function is used to manually adjust the offsets for the analog monitor outputs (torque reference monitor output and motor speed monitor output). The offset values are factory-set before shipping. Therefore, the user need not usually use this function.
(1) Adjustment Example
An example of offset adjustment to the motor speed monitor is shown below.
Analog monitor output voltage
Offset adjustment
Motor speed
6-14
Item
Offset Adjustment Range
Adjustment Unit
Specifications
-2.4 V to + 2.4 V
18.9 mV/LSB
Note:
• The adjustment value will not be initialized when parameter settings are initialized using Fn005.
• Make offset adjustment with a measuring instrument connected, so that the analog monitor output is zero. An example of settings for a zero analog monitor output is shown below.
• While the servomotor is not turned ON, set the monitor signal to the torque reference.
• In speed control, set the monitor signal to the position error.
(2) Preparation
The following condition must be met to adjust the offsets of the analog monitor output.
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
(3) Operating Procedure
Use the following procedure to perform the offset adjustment of analog monitor output.
Keys Step
1
Display after Operation
B B − F U N C T I O N −
F n 0 0 B : T r q A d j
F n 0 0 C : M o n Z e r o A d j
F n 0 0 D : M o n G a i n A d j
F n 0 0 E : C u r A u t o A d j
2
B B − Z e r o A D J −
C H 1 = − 0 0 0 0 2
C H 2 = − 0 0 0 0 1
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn00C.
Key to move through the list and
Press the Key. The display changes to the Fn00C execution display.
6.8 Offset Adjustment of Analog Monitor Output (Fn00C)
Step
3
4
Display after Operation
B B
−
Z e r o A D J
−
C H 1 = − 0 0 0 0 5
C H 2 = − 0 0 0 0 1
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
B B − Z e r o A D J −
C H 1 = − 0 0 0 0 5
C H 2 = − 0 0 0 0 1
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
5
B B − Z e r o A D J −
C H 1 = − 0 0 0 0 5
C H 2 = − 0 0 0 0 6
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
6
B B − Z e r o A D J −
C H 1 =
−
0 0 0 0 5
C H 2 = − 0 0 0 0 6
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
7
B B − F U N C T I O N −
F n 0 0 B : T r q A d j
F n 0 0 C : M o n Z e r o A d j
F n 0 0 D : M o n G a i n A d j
F n 0 0 E : C u r A u t o A d j
Keys
(cont’d)
Operation
Press the or Key to adjust the offset of CH1
(torque reference monitor).
Adjust the offset so that the measurement instrument reading is as close to 0 V as possible.
After the offset adjustment of CH1 has completed, adjust the offset of CH2 (motor rotating speed monitor).
Press the Key. The cursor moves to CH2 side.
Adjust the offset of CH2 in the same way as for CH1.
Press the or Key to adjust the offset of
CH2.
Adjust the offset so that the measurement instrument reading is as close to 0 V as possible.
After having completed the offset adjustment both for
CH1 and CH2, press the Key.
The adjustment results are saved in the SERVO-
PACK, and the status display shows "DONE" for one second. The status display then returns to show "BB" again.
Press the Key.
The display returns to the main menu of the utility function.
6
6-15
6-16
6 Utility Functions (Fn )
6.9
Gain Adjustment of Analog Monitor Output (Fn00D)
This function is used to manually adjust the gains for the analog monitor outputs (torque reference monitor output and motor rotating speed monitor output). The gain values are factory-set before shipping. Therefore, the user need not usually use this function.
(1) Adjustment Example
An example of gain adjustment to the motor rotating speed monitor is shown below.
Rotation
Analog monitor output voltage
1 [V]
Gain adjustment
1000 [min
-1
]
Motor speed
Item
Gain-adjustment Range
Adjustment Unit
Specifications
100 ± 50%
0.4%/LSB
The gain adjustment range is made with a 100% output set as a center value (adjustment range: 50% to 150%).
The following is a setting example.
<Setting the Set Value to -125>
100% + (–125 × 0.4) = 50%
Therefore, the monitor output voltage is 0.5 time as high.
<Setting the Set Value to 125>
100% + (125 × 0.4) = 150%
Therefore, the monitor output voltage is 1.5 times as high.
Note: The adjustment value will not be initialized when parameter settings are initialized using Fn005.
(2) Preparation
The following condition must be met to adjust the gain of the analog monitor output.
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
6.9 Gain Adjustment of Analog Monitor Output (Fn00D)
(3) Operating Procedure
Use the following procedure to perform the gain adjustment of analog monitor output.
Keys Step
1
Display after Operation
B B − F U N C T I O N −
F n 0 0 C : M o n Z e r o A d j
F n 0 0 D : M o n G a i n A d j
F n 0 0 E : C u r A u t o A d j
F n 0 0 F : C u r M a n u A d j
2
3
4
5
B B − G a i n A D J −
C H 1 =
−
0 0 0 0 1
C H 2 = − 0 0 0 0 1
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
B B − G a i n A D J −
C H 1 = − 0 0 1 2 5
C H 2 = − 0 0 0 0 1
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
B B − G a i n A D J −
C H 1 = − 0 0 1 2 5
C H 2 = − 0 0 0 0 1
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
B B − G a i n A D J −
C H 1 = − 0 0 1 2 5
C H 2 =
−
0 0 1 2 5
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
6
B B − G a i n A D J −
C H 1 = − 0 0 1 2 5
C H 2 = − 0 0 1 2 5
U n 0 0 2 = 0 0 0 0 0 0
U n 0 0 0 = 0 0 0 0 0 0
7
B B
−
F U N C T I O N
−
F n 0 0 C : M o n Z e r o A d j
F n 0 0 D : M o n G a i n A d j
F n 0 0 E : C u r A u t o A d j
F n 0 0 F : C u r M a n u A d j
Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn00D.
Key to move through the list and
Press the Key. The display changes to the Fn00D execution display.
Press the or Key to adjust the gain adjustment width of CH1 (torque reference monitor).
After the gain adjustment of CH1 has completed, adjust the gain adjustment width of CH2 (motor rotating speed monitor).
Press the Key. The cursor moves to CH2 side.
Adjust the gain of CH2 in the same way as for CH1.
Press the or ment width of CH2.
Key to adjust the gain adjust-
After having completed the adjustment both for CH1 and CH2, press the Key.
The adjustment results are saved in the SERVO-
PACK, and the status display shows "DONE" for one second. The status display then returns to show "BB" again.
Press the Key.
The display returns to the main menu of the utility function.
6
6-17
6-18
6 Utility Functions (Fn )
6.10
Automatic Offset-Signal Adjustment of the Motor Current
Detection Signal (Fn00E)
Perform this adjustment only if highly accurate adjustment is required for reducing torque ripple caused by current offset. The user need not usually use this function.
• Be sure to perform this function while the servomotor power is OFF.
• Execute the automatic offset adjustment if the torque ripple is too big when compared with those of other SERVOPACKs.
Note: The adjusted value is not initialized by executing the Fn005 function (Initializing Parameter Settings).
(1) Preparation
The following conditions must be met to automatically adjust the offset of the motor current detection signal.
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
• The SERVOPACK must be in Servo Ready status (Refer to 4.8.4
).
• The servomotor power must be OFF.
(2) Operating Procedure
Use the following procedure.
Keys Step
1
Display after Operation
B B − F U N C T I O N −
F n 0 0 D : M o n G a i n A d j
F n 0 0 E : C u r A u t o A d j
F n 0 0 F : C u r M a n u A d j
F n 0 1 0 : P r m P r o t e c t
2
B B
A u t o O f f s e t
−
A D J
o f M o t o r C u r r e n t
S t a r t : [ D A T A ]
R e t u r n : [ S E T ]
3
B B
A u t o O f f s e t − A D J
o f M o t o r C u r r e n t
S t a r t : [ D A T A ]
R e t u r n : [ S E T ]
Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn00E.
Key to move through the list and
Press the Key. The display changes to the Fn00E execution display.
Press the Key to start the automatic offset-signal adjustment of motor current detection.
When the adjustment is completed, the status display shows "DONE" for one second. The status display then returns to show "BB" again.
Note: Press the Key to cancel the automatic adjustment. The display returns to the main menu of the utility function.
6.11 Manual Offset-Signal Adjustment of the Motor Current Detection Signal (Fn00F)
6.11
Manual Offset-Signal Adjustment of the Motor Current
Detection Signal (Fn00F)
Use this function only if the torque ripple is still high after the automatic offset-signal adjustment of the motor current detection signal (Fn00E).
If this function is adjusted incorrectly and then executed, characteristics of the servomotor performance could be affected.
Observe the following precautions when performing manual servo tuning.
• Run the servomotor at a speed of approximately 100 min
-1
.
• Adjust the offset while monitoring the torque reference with the analog monitor until the ripple of torque reference monitor's waveform is minimized.
• Adjust the phase-U and phase-V offset amounts alternately several times until these offsets are well balanced.
Note: The adjusted value is not initialized by executing the Fn005 function (Initializing Parameter Settings).
(1) Preparation
The following condition must be met to manually adjust the offset of the motor current detection signal.
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
• The main circuit power must be ON.
• All alarms must be cleared.
• The hardwire baseblock (HWBB) must be disabled.
(2) Operating Procedure
Use the following procedure.
Step
1
Display after Operation
B B − F U N C T I O N −
F n 0 0 F : C u r M a n u A d j
F n 0 1 0 : P r m P r o t e c t
F n 0 1 1 : M o t o r I n f o
F n 0 1 2 : S o f t V e r
2
3
B B
M a n u a l O f f s e t − A D J
o f M o t o r C u r r e n t
Z A D J I U = - 0 0 0 0 9
Z A D J I V = - 0 0 0 0 6
R U N
M a n u a l O f f s e t
−
A D J
o f M o t o r C u r r e n t
Z A D J I U = - 0 0 0 0 9
Z A D J I V = - 0 0 0 0 6
Keys
–
Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn00F.
Key to move through the list and
Press the Key.
The display changes to the Fn00F execution display.
4
R U N
M a n u a l O f f s e t − A D J
o f M o t o r C u r r e n t
Z A D J I U = - 0 0 0 1 9
Z A D J I V = - 0 0 0 0 6
5
R U N
M a n u a l O f f s e t − A D J
o f M o t o r C u r r e n t
Z A D J I U = - 0 0 0 1 9
Z A D J I V = - 0 0 0 0 6
Send an SV_ON command from the host controller.
Adjust the phase-U offset.
Press the amount.
or Key to adjust the offset
Adjust the offset amount by 10 in the direction that the torque ripple is reduced.
Adjustment range: -512 to +511
(ZADJIU: Offset value of phase-U current)
Adjust the phase-V offset.
Press the Key. The cursor moves to the phase-V side.
6
6-19
6-20
6 Utility Functions (Fn )
Step
6
7
(cont’d)
Display after Operation Keys Operation
R U N
M a n u a l O f f s e t − A D J
o f M o t o r C u r r e n t
Z A D J I U = - 0 0 0 1 9
Z A D J I V = - 0 0 0 1 6
Press the amount.
or Key to adjust the offset
Adjust the offset amount by 10 in the direction that the torque ripple is reduced.
Adjustment range: -512 to +511
(ZADJIV: Offset value of phase-V current)
Repeat the operations of steps 4 to 6 (phase-U and-V alternately) until adjusting the offset amounts both for phase-U and -V in both directions cannot reduce the torque ripple any more.
Then, perform the same operation by adjusting by smaller amount.
R U N
M a n u a l O f f s e t − A D J
o f M o t o r C u r r e n t
Z A D J I U = - 0 0 0 1 9
Z A D J I V = - 0 0 0 1 6
Press the Key to save the result of adjustment in the SERVOPACK.
When the saving is completed, the status display shows "DONE" for one second. The status display then returns to show "RUN" again.
8
R U N − F U N C T I O N −
F n 0 0 F : C u r M a n u A d j
F n 0 1 0 : P r m P r o t e c t
F n 0 1 1 : M o t o r I n f o
F n 0 1 2 : S o f t V e r
Press the Key.
The display returns to the main menu of the utility function.
6.12 Write Prohibited Setting (Fn010)
6.12
Write Prohibited Setting (Fn010)
This function prevents changing parameters by mistake and sets restrictions on the execution of the utility function.
Parameter changes and execution of the utility function become restricted in the following manner when Write prohibited (P.0001) is assigned to the write prohibited setting parameter (Fn010).
• Parameters: Cannot be changed. If you attempt to change it, "NO-OP" will flash on the display and the screen will return to the main menu.
• Utility Function: Some functions cannot be executed. (Refer to the following table.) If you attempt to execute these utility functions, "NO-OP" will flash on the display and the screen will return to the main menu.
Fn202
Fn203
Fn204
Fn205
Fn206
Fn207
Fn014
Fn01B
Fn01E
Fn01F
Fn020
Fn030
Fn200
Fn201
Parameter
No.
Fn000
Fn002
Fn003
Fn004
Fn005
Fn006
Fn008
Fn00C
Fn00D
Fn00E
Fn00F
Fn010
Fn011
Fn012
Fn013
Function
Alarm history display
JOG operation
Origin search
Program JOG operation
Initializing parameter settings
Clearing alarm history
Absolute encoder multiturn reset and encoder alarm reset
Offset adjustment of analog monitor output
Gain adjustment of analog monitor output
Automatic offset-signal adjustment of the motor current detection signal
Manual offset-signal adjustment of the motor current detection signal
Write prohibited setting
Servomotor model display
Software version display
Multiturn limit value setting change when a multiturn limit disagreement alarm occurs
Resetting configuration error in option modules
Vibration detection level initialization
Display of SERVOPACK and servomotor ID
Display of servomotor ID in feedback option module
Origin setting
Software reset
Tuning-less levels setting
Advanced autotuning
Advanced autotuning by reference
One-parameter tuning
Anti-resonance control adjustment function
Vibration suppression function
EasyFFT
Online vibration monitor
Write Prohibited
Setting
Executable
Cannot be executed
Cannot be executed
Cannot be executed
Cannot be executed
Cannot be executed
Cannot be executed
Cannot be executed
Cannot be executed
Cannot be executed
Cannot be executed
–
Executable
Executable
Cannot be executed
Cannot be executed
Cannot be executed
Executable
Executable
Cannot be executed
Executable
Cannot be executed
Cannot be executed
Cannot be executed
Cannot be executed
Cannot be executed
Cannot be executed
Cannot be executed
Cannot be executed
Reference
Section
6.2
6.3
6.4
6.5
6.6
6.7
4.7.4
6.8
6.9
6.10
6.11
6.12
6.13
6.14
4.7.7
5.4.2
5.5.2
5.6.2
5.7.2
6.21
6.22
6.15
6.16
6.17
6.18
6.19
6.20
5.2.2
5.3.2
6
6-21
6-22
6 Utility Functions (Fn )
(1) Preparation
There are no tasks that must be performed before the execution.
(2) Operating Procedure
Follow the steps to set enable or disable writing.
Setting values are as follows:
• " P.0000
" : Write permitted (Releases write prohibited mode.) [Factory setting]
• " P.0001
" : Write prohibited (Parameters become write prohibited from the next power ON.)
Step
1
Display after Operation
B B − F U N C T I O N −
F n 0 0 F : C u r M a n u A d j
F n 0 1 0 : P r m P r o t e c t
F n 0 1 1 : M o t o r I n f o
F n 0 1 2 : S o f t V e r
Keys Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn010.
Key to move through the list and
2
B B
P a r a m e t e r
W r i t e P r o t e c t
P . 0 0 0 0
Press the Key. The display changes to the Fn010 execution display.
3
B B
P a r a m e t e r
W r i t e P r o t e c t
P . 0 0 0 1
Press the or Key to select one of the following settings.
P.0000: Write permitted [Factory setting]
P.0001: Write prohibited
4
B B
P a r a m e t e r
W r i t e P r o t e c t
P . 0 0 0 1
Press the Key. The setting value is written into the SERVOPACK, and the status display changes as follows: "BB" to "DONE" to "BB."
Note: Saved settings will be enabled after the SER-
VOPACK is restarted.
5 To enable the change in the setting, turn the power OFF and ON again.
Note: To make the setting available, change the setting to P.0000 as shown in step 3.
6.13 Servomotor Model Display (Fn011)
6.13
Servomotor Model Display (Fn011)
This function is used to check the servomotor model, voltage, capacity, encoder type, and encoder resolution.
If the SERVOPACK has been custom-made, you can also check the specification codes of SERVOPACKs.
(1) Preparation
There are no tasks that must be performed before the execution.
(2) Operating Procedure
Use the following procedure.
Step
1
Display after Operation
㧮㧮ޓޓޓޓ㧙㧲㨁㧺㧯㨀㧵㧻㧺㧙
㧲㨚㧜㧝㧜㧦㧼㨞㨙ޓ㧼㨞㨛㨠㨑㨏㨠
㧲㨚㧜㧝㧝㧦㧹㨛㨠㨛㨞ޓ㧵㨚㨒㨛
㧲㨚㧜㧝㧞㧦㧿㨛㨒㨠ޓ㨂㨑㨞
㧲㨚㧜㧝㧟㧦㧹㨠㨡㨞㨚㧸㨙㧿㨑㨠ޓ
Keys Operation
Press the Key to view the main menu for the utility function.
Use the select Fn011.
or Key to move through the list and
2
Servomotor Model
Code Model
71
73
SGMVV-
SGMVV-
B
D
Servomotor input voltage
B B − M o t o r l n f o −
T Y P E 7 1 A C 4 0 0 V
2 2 0 0 0 W
E N C O R D E R 0 1 2 0 b i t
Press the Key. The display changes to the Fn011 execution display and shows the information about the servomotor and encoder being used.
3
Code
01
Encoder Type
00 Incremental
Type
Multiturn absolute value
Servomotor capacity
Encoder
Resolution
Code Resolution
20 20 bit
㧮㧮ޓޓޓޓޓ㧙㧲㨁㧺㧯㨀㧵㧻㧺㧙
㧲㨚㧜㧝㧜㧦㧼㨞㨙ޓ㧼㨞㨛㨠㨑㨏㨠
㧲㨚㧜㧝㧝㧦㧹㨛㨠㨛㨞ޓ㧵㨚㨒㨛
㧲㨚㧜㧝㧞㧦㧿㨛㨒㨠ޓ㨂㨑㨞
㧲㨚㧜㧝㧟㧦㧹㨠㨡㨞㨚㧸㨙㧿㨑㨠ޓ
Press the Key. The display returns to the main menu of the utility function.
6
6-23
6-24
6 Utility Functions (Fn )
6.14
Software Version Display (Fn012)
Select Fn012 to check the SERVOPACK and encoder software version numbers.
(1) Preparation
There are no tasks that must be performed before the execution.
(2) Operating Procedure
Use the following procedure.
Keys Step
1
Display after Operation
B B − F U N C T I O N −
F n 0 1 1 : M o t o r I n f o
F n 0 1 2 : S o f t V e r
F n 0 1 3 : M t u r n L m S e t
F n 0 1 4 : O p t I n i t
2
B B − S o f t V e r −
D R I V E R
V e r . = 0 0 0 1
E N C O D E R
V e r . = 0 0 0 3
3
B B − F U N C T I O N −
F n 0 1 1 : M o t o r I n f o
F n 0 1 2 : S o f t V e r
F n 0 1 3 : M t u r n L m S e t
F n 0 1 4 : O p t I n i t
Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn012.
Key to move through the list and
Press the Key. The display changes to the Fn012 execution display.
The software versions of the SERVOPACK and the connected encoder will appear.
Note: If the servomotor is not connected, "Not connect" is displayed.
Press the Key. The display returns to the main menu of the utility function.
6.15 Resetting Configuration Errors in Option Modules (Fn014)
6.15
Resetting Configuration Errors in Option Modules (Fn014)
The SERVOPACK with option module recognizes installation status and types of option modules that are connected to SERVOPACK. If an error is detected, the SERVOPACK issues an alarm. This function clears these alarms.
Note 1. Alarms related to option module can be cleared only by this function. These alarms cannot be cleared by alarm reset or turning OFF the main circuit power supply.
2. Before clearing the alarm, perform corrective action for the alarm.
(1) Preparation
The following condition must be met to clear detection alarms of the option module.
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
(2) Operating Procedure
Use the following procedure.
Keys Step
1
2
Display after Operation
B B − F U N C T I O N −
F n 0 1 3 : M t u r n L m S e t
F n 0 1 4 : O p t I n i t
F n 0 1 B : V i b l v l I n i t
F n 0 1 E : S v M o t O p I D
B B
−
O p t I n i t
−
0 2 : S a f e t y O p t
0 3 : F e e d b a c k O p t
3
B B − O p t I n i t −
0 2 : S a f e t y O p t
0 3 : F e e d b a c k O p t
Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn014.
Key to move through the list and
Press the Key. The display changes to the Fn014 execution display.
Press the to be cleared.
or Key to select an option module
4
B B − O p t I n i t −
F e e d b a c k O p t
I n i t i a l i z e
S t a r t : [ D A T A ]
R e t u r n : [ S E T ]
Press the appears.
Key. The display shown on the left
5
B B − O p t I n i t −
0 2 : S a f e t y O p t
0 3 : F e e d b a c k O p t
Press the Key to clear the configuration error of the option module.
The error is cleared and the status display shows
"DONE" for one second. The status display then returns to step 3.
6
B B − F U N C T I O N −
F n 0 1 3 : M t u r n L m S e t
F n 0 1 4 : O p t I n i t
F n 0 1 B : V i b l L v l I n i t
F n 0 1 E : S v M o t O p I D
Press the Key. The display returns to the main menu of the utility function.
7 To enable the change in the setting, turn the power OFF and ON again.
6
6-25
6-26
6 Utility Functions (Fn )
6.16
Vibration Detection Level Initialization (Fn01B)
This function detects vibration when servomotor is connected to a machine in operation and automatically adjusts the vibration detection level (Pn312) to output more exactly the vibration alarm (A.520) and the vibration warning (A.911).
The vibration detection function detects vibration elements according to the motor speed.
Parameter n.
0
[Factory setting]
Meaning
Does not detect vibration.
When Enabled Classification
Pn310 n.
1
Outputs the warning (A.911) when vibration is detected.
Outputs the alarm (A.520) when vibration is detected.
Immediately Setup n.
2
If the vibration exceeds the detection level calculated by the following formula, the alarm or warning will be output according to the setting of vibration detection switch (Pn310).
Rotation
Vibration detection level (Pn312 [min
Detection level = ޓ
-1
])
100
×
Vibration detection sensitivity (Pn311 [%])
• Use this function if the vibration alarm (A.520) or the vibration warning (A.911) is not output correctly when a vibration at the factory setting of the vibration detection level (Pn312) is detected. In other cases, it is not necessary to use this function.
• The vibration alarm or warning detection sensibility differs depending on the machine conditions. In this case, fine-tune the setting of the vibration detection sensitivity (Pn311) using the above detection level formula as a guide.
Pn311
Vibration Detection Sensitivity
Setting Range
50 to 500
Setting Unit
1%
Speed Position
Factory Setting
100
Torque
When Enabled
Immediately
Classification
Tuning
• The vibration may not be detected because of improper servo gains. Also, not all kinds of vibrations can be detected. Use the detection result as a guideline.
• Set a proper moment of inertia ratio (Pn103). Improper setting may result in the vibration alarm, warning misdetection, or non-detection.
• The references that are used to operate your system must be input to execute this function.
• Execute this function under the operating condition for which the vibration detection level should be set.
• Execute this function while the motor speed reaches at least 10% of its maximum.
(1) Preparation
The following conditions must be met to initialize the vibration detection level.
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
• The test without a motor function must be disabled (Pn00C.0 = 0).
(2) Operating Procedure
Use the following procedure.
Step
1
Display after Operation
R U N − F U N C T I O N −
F n 0 1 4 : O p t I n i t
F n 0 1 B : V i b l v l I n i t
F n 0 1 E : S v M o t O p I D
F n 0 1 F : F B O p M o t I D
Keys Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn01B.
Key to move through the list and
6.16 Vibration Detection Level Initialization (Fn01B)
Step
2
Display after Operation
R U N
V i b r a t i o n D e t e c t
L e v e l I n i t
S t a r t : [ D A T A ]
R e t u r n : [ S E T ]
3
R U N
V i b r a t i o n D e t e c t
L e v e l I n i t
I n i t
4
5
R U N
V i b r a t i o n D e t e c t
L e v e l I n i t
D 㧻 㧺 㧱
R U N
−
F U N C T I O N
−
F n 0 1 4 : O p t I n i t
F n 0 1 B : V i b l v l I n i t
F n 0 1 E : S v M o t O p I D
F n 0 1 F : F B O p M o t I D
Keys
(cont’d)
Operation
Press the Key. The display changes to the Fn01B execution display.
Press the Key.
"Init" is displayed flashing, and the vibration level is detected and initialized.
Note: Continues initialization until the Key is pressed again.
Press the Key. The display changes from "Init" to "DONE," for one second and the new setting of
Pn312 becomes enabled.
Press the Key. The display returns to the main menu of the utility function.
(3) Related Parameters
The following table lists parameters related to this function and their possibility of being changed while executing this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes : Parameters can be changed using SigmaWin+ while this function is being executed.
No : Parameters cannot be changed using SigmaWin+ while this function is being executed.
• Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
Parameter
Pn311
Pn312
Name
Vibration Detection Sensitivity
Vibration Detection Level
Mid-execution changes
Yes
No
Automatic changes
No
Yes
6
6-27
6-28
6 Utility Functions (Fn )
6.17
Display of SERVOPACK and Servomotor ID (Fn01E)
This function displays ID information for SERVOPACK, servomotor, encoder, and option module connected to the SERVOPACK. The ID information of some option modules (SGDV-OFA01A) is not stored in the SER-
VOPACK. "Not available" will be displayed for these option modules.
To use this function, the digital operator (JUSP-OP05A-1-E) or SigmaWin+ is needed.
Refer to Σ -V Series User's Manual, Operation of Digital Operator procedure of the digital operator.
(No.: SIEP S800000 55) for the operating
The following items can be displayed.
Feedback Option
Module ID
*
ID
SERVOPACK ID
Servomotor ID
Encoder ID
Safety Option Module
ID
*
Items to be Displayed
• SERVOPACK model
• SERVOPACK serial number
• SERVOPACK manufacturing date
• SERVOPACK input voltage (V)
• Maximum applicable motor capacity (W)
• Maximum applicable motor rated current (Arms)
• Servomotor model
• Servomotor order number
• Servomotor manufacturing date
• Servomotor input voltage (V)
• Servomotor capacity (W)
• Servomotor rated current (Arms)
• Encoder model
• Encoder serial number
• Encoder manufacturing date
• Encoder type/resolution
• Safety Option Module model
• Safety Option Module serial number
• Safety Option Module manufacturing date
• Safety Option Module ID number
• Feedback Option Module model
• Feedback Option Module serial number (Reserved area)
• Feedback Option Module manufacturing date
• Feedback Option Module ID
∗ If the option module is not connected, "Not connect" will be displayed after the module name.
(1) Preparation
There are no tasks that must be performed before the execution.
6.17 Display of SERVOPACK and Servomotor ID (Fn01E)
(2) Operating Procedure
Use the following procedure.
Step
1
2
Display after Operation
Rotation
−
F U N C T I O N
−
F n 0 1 B : V i b l v l I n i t
F n 0 1 E : S v M o t O p I D
F n 0 1 F : F B O p M o t I D
F n 0 2 0 : S − O r i g S e t
M-II Serial number
SERVOPACK model
B B − S v M o t O p I D −
D r i v e r
S G D V − 7 5 0 J 1 1 A
D 0 0 2 4 1 2 3 4 5 9 0 0 0 1
1 2 . 0 7 4 0 0 V , 2 2 0 0 0 W
3
4
Manufacturing date
SERVOPACK input voltage
SERVOPACK capacity
Servomotor order number
Servomotor model
B B − S v M o t O p I D −
M o t o r
S G M V V − 2 B D D B 2 N
1 2 3 4 5 6 − 1 − B K 1
1 2 . 0 7 4 0 0 V , 2 2 0 0 0 W
Manufacturing date
Servomotor voltage
Servomotor capacity
Rotation
Encoder serial number
Encoder model
B B ޓ − S v M o t O p I D −
E n c o d e r
U T T I H − B 2 0 F N
Q 1 2 3 4 5 − 0 0 1 − B K 6
1 2 . 0 7 2 0 b i t − I N C
Manufacturing date
Encoder resolution
Encoder type
5
R U N − F U N C T I O N −
F n 0 1 B : V i b l v l I n i t
F n 0 1 E : S v M o t O p I D
F n 0 1 F : F B O p M o t I D
Rotati on
F n 0 2 0 : S − O r i g S e t
Keys Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn01E.
Key to move through the list and
Press the Key.
The display changes to the Fn01E execution display.
The SERVOPACK ID information is displayed. Use the or Key to scroll left and right and to view other information.
Press the Key.
The servomotor ID information is displayed. Use the
or Key to scroll left and right and to view other information.
Press the Key.
The encoder ID information is displayed.
Use the or Key to scroll left and right and to view other information.
Press the Key.
The display returns to the main menu of the utility function.
6
6-29
6-30
6 Utility Functions (Fn )
6.18
Display of Servomotor ID in Feedback Option Module (Fn01F)
This function displays ID information for servomotor and encoder in Feedback Option Module connected to the SERVOPACK. If the option module is not connected, "Not connect" will be displayed after the module name.
To use this function, the digital operator (JUSP-OP05A-1-E) or SigmaWin+ is needed.
Refer to Σ -V Series User's Manual, Operation of Digital Operator procedure of the digital operator.
(No.: SIEP S800000 55) for the operating
The following items can be displayed.
ID
Servomotor ID
Encoder ID
Items to be Displayed
• Servomotor model
• Servomotor order number
• Servomotor input voltage (V)
• Servomotor capacity (W)
• Servomotor rated current (Arms)
• Encoder model
• Encoder serial number
• Encoder type/resolution (Two types of resolution display available: Number of bits and number of pulses/rev.)
(1) Preparation
There are no tasks that must be performed before the execution.
(2) Operating Procedure
Use the following procedure.
Step
1
Display after Operation
B B − F U N C T I O N −
F n 0 1 E : S v M o t O p I D
F n 0 1 F : F B O p M o t I D
F n 0 2 0 : S − O r i g S e t
F n 0 3 0 : S o f t R e s e t
Keys Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn01F.
Key to move through the list and
2
*
3
Servomotor order number
Servomotor model
B B
−
F B O p M o t I D
−
M o t o r
S G M V V − 2 B D D B 2 N
1 2 3 4 5 6 − 1 − B K 1
4 0 0 V , 2 2 0 0 0 W
Input voltage Capacity
Encoder type/resolution
Encoder serial number
Encoder model
B B − F B O p M o t I D −
E n c o d e r
U T T I H − B 2 0 F N
Q 1 2 3 4 5 − 0 0 1 − B K 6
2 0 b i t
−
I N C
Press the Key.
The display changes to the Fn01F execution display.
The servomotor ID information is displayed. Use the
or Key to scroll left and right and to view other information.
Press the Key.
The encoder ID information is displayed.
Use the or Key to scroll left and right and to view other information.
4
B B − F U N C T I O N −
F n 0 1 E : S v M o t O p I D
F n 0 1 F : F B O p M o t I D
F n 0 2 0 : S − O r i g S e t
F n 0 3 0 : S o f t R e s e t
Press the Key.
The display returns to the main menu of the utility function.
∗ When fully-closed loop control is being used, step 2 is not included.
6.19 Origin Setting (Fn020)
6.19
Origin Setting (Fn020)
When using an external absolute encoder for fully-closed loop control, this function is used to set the current position of the external absolute encoder as the origin (zero point position).
This function can be used with the following products.
Mitutoyo Corporation
ABS ST780A series
Model: ABS ST78 A/ST78 AL
• After execution of origin setting, the servo ready (/S-RDY) signal will become inactive because the system position data will have been changed. Always turn the power supply OFF and then ON again after execution of origin setting.
(1) Preparation
The following conditions must be met to set the origin.
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
• The servomotor power must be OFF.
(2) Operating Procedure
Use the following procedure.
Step
1
Display after Operation
B B − F U N C T I O N −
F n 0 1 F : F B O p M o t I D
F n 0 2 0 : S − O r i g S e t
F n 0 3 0 : S o f t R e s e t
F n 0 8 0 : P o l e D e t e c t
Keys Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn020.
Key to move through the list and
2
B B
S c a l e O r i g i n S e t
O R G S E T 1
Press the Key. The display changes to the Fn020 execution display.
B B
3
S c a l e O r i g i n S e t
Press the or Key to "ORGSET5".
O R G S E T 5
4
B B
S c a l e O r i g i n S e t
Press the key to start setting the origin. The message, "Scale Origin Set," flashes while the origin is being set. After the origin has been successfully set, the displayed status changes as follows: "BB" to
"DONE" to "BB".
5 To enable the change in the setting, turn the power OFF and ON again.
6
6-31
6-32
6 Utility Functions (Fn )
6.20
Software Reset (Fn030)
This function enables resetting the SERVOPACK internally from software. This function is used when resetting alarms and changing the settings of parameters that normally require restarting the SERVOPACK. This function can be used to change those parameters without restarting the SERVOPACK.
• Start software reset operation after the servomotor power is OFF.
• This function resets the SERVOPACK independently of host controller. The SERVO-
PACK carries out the same processing as when the power supply is turned ON and outputs the ALM signal. The status of other output signals may be forcibly changed.
(1) Preparation
The following condition must be met to perform a software reset.
• The servomotor power must be OFF.
(2) Operating Procedure
Use the following procedure.
Step
1
Display after Operation
B B − F U N C T I O N −
F n 0 2 0 : S − O r i g S e t
F n 0 3 0 : S o f t R e s e t
F n 0 8 0 : P o l e D e t e c t
F n 2 0 0 : T u n e L v l S e t
2
B B
S o f t w a r e R e s e t
R E S E T 1
Keys Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn030.
Key to move through the list and
Press the Key. The display changes to the Fn030 execution display.
3
4
B B
S o f t w a r e R e s e t
R E S E T 5
B B
S o f t w a r e R e s e t
Press the or Key to select "RESET5".
5
F i l e F i r s t L o a d i n g
P l e a s e W a i t . . .
–
Press the Key to execute the software reset.
After the software reset starts, "RESET5" will no longer be displayed.
After the reset has been successfully completed, the screen which appears when the power is turned ON will be displayed. The screen will then show parameters or monitor displays.
6
B B − F U N C T I O N −
F n 0 2 0 : S − O r i g S e t
F n 0 3 0 : S o f t R e s e t
F n 0 8 0 : P o l e D e t e c t
F n 2 0 0 : T u n e L v l S e t
Press the Key.
The display returns to the main menu of the utility function.
6.21 EasyFFT (Fn206)
6.21
EasyFFT (Fn206)
EasyFFT sends a frequency waveform reference from the SERVOPACK to the servomotor and slightly rotates the servomotor several times over a certain period, thus causing machine vibration. The SERVOPACK detects the resonance frequency from the generated vibration and makes notch filter settings according to the resonance frequency detection. The notch filter is effective for the elimination of high-frequency vibration and noise.
Execute this function after the servomotor power is turned OFF if operation of the SERVOPACK results in high-frequency vibration and noise.
WARNING
• The servomotor rotates slightly when EasyFFT is executed. Do not touch the servomotor or machine during execution of EasyFFT, otherwise injury may result.
CAUTION
• Use the EasyFFT when the servo gain is low, such as in the initial stage of servo adjustment. If EasyFFT is executed after increasing the gain, the servo system may vibrate depending on the machine characteristics or gain balance.
Periodic waveform reference
Response
M-II
Rotates the shaft slightly
Slight movement
SERVOPACK
In addition to this function, online vibration monitor (Fn207) can be used to detect machine vibration and automatically make notch filter settings.
If a Σ -V large-capacity SERVOPACK is used to make adjustments, it is recommended to use advanced autotuning. This built-in EasyFFT function is used to maintain interchangeability with previous models. There is normally no need to use it.
(1) Preparation
The following conditions must be met to perform EasyFFT.
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
• The main circuit power supply must be ON.
• All alarms must be cleared.
• The hardwire baseblock (HWBB) must be disabled.
• The servomotor power must be OFF.
• There must be no overtravel.
• The test without a motor function must be disabled (Pn00C.0 = 0).
• An external reference must not be input.
6
6-33
6-34
6 Utility Functions (Fn )
(2) Operating Procedure
Use the following procedure.
Step Display after Operation
1
B B − F U N C T I O N −
F n 2 0 5 : V i b S u p
F n 2 0 6 : E a s y F F T
F n 2 0 7 : V - M o n i t o r
F n 0 0 0 : A l m H i s t o r y
2
B B − E a s y F F T −
S e t t i n g
I n p u t = 0 1 5 %
3
B B − E a s y F F T −
S e t t i n g
I n p u t = 0 1 5 %
4
R U N − E a s y F F T −
R e a d y
I n p u t = 0 1 5 %
5
R U N
−
E a s y F F T
−
M e a s u r e
I n p u t = 0 1 5 %
6
B B − E a s y F F T −
R e s u l t
I n p u t = 0 1 5 %
R e s = 1 2 5 0 H z
F i l t e r 1 1 2 5 0 H z
Keys Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn206.
Key to move through the list and
Press the Key. The display changes to the Fn206 execution display.
The cursor is on the setting of "Input." Press the or Key to set the sweep torque reference amplitude (Pn456)
Setting range: 1 to 800.
Note: When making the initial settings for EasyFFT, do not change the setting for the reference amplitude. Start with the original value of 15.
Increasing reference amplitude increases the detection accuracy, but the vibration and noise from the machine will increase. Increase the amplitude value little by little.
Press the Key to turn the servomotor power ON.
The display “BB” and “Setting” changes to “RUN” and “Ready.”
Press the (forward run start) Key or
(reverse run start) Key to run the servomotor and start the frequency measurement. "Measure" is displayed during the measurement.
Within a quarter turn, the servomotor will move forward and then in reverse several times.
Notes:
• Press the Key to cancel the measurement. The servomotor stops moving and the power turns OFF.
The detection of the resonance frequency is not completed.
• The actions of the servomotor are very minute in this operation. Also at the same time, the servomotor emits a noise. To ensure safety, do not enter the working envelope of the motor.
When the detection processing is successfully completed, "Measure" stops flashing and the results and the notch filter value to be set are displayed. If the processing was not completed, "No Measure" is displayed. To check the results, go to step 8.
< Important >
If two seconds or more are required for the operation although detection was successfully completed, the detection accuracy might be insufficient. Increasing reference amplitude more than 15 increases the detection accuracy, but the vibration and noise from the machine will increase. Increase the amplitude value little by little.
Notes:
• If a notch filter has been set and is being used, "*" is displayed on the second line.
• If the first stage notch filter has been set, the second stage notch filter value is displayed. If the first and second stage notch filters have been set, only the result of frequency detection is displayed.
6.21 EasyFFT (Fn206)
Step
7
Display after Operation
B B − E a s y F F T −
R e a d y
I n p u t = 0 1 5 %
Keys
(cont’d)
Operation
To exit the EasyFFT function at this stage, press the Key. The power to the servomotor is turned
OFF and the display returns to the main menu of the utility function.
To remeasure the vibration frequency, press the Key to return to step 4. Execute steps 5 to 7.
8
D 㧻 㧺 㧱 − E a s y F F T −
R e s u l t
I n p u t = 0 1 5 %
R e s = 1 2 5 0 H z
F i l t e r 1 1 2 5 0 H z
Press the Key after the normal completion of frequency detection. The notch filter frequencies are automatically updated to the optimum values.
The status display shows "DONE" and the display shown on the left appears.
If the first stage notch filter frequency has been set
(Pn408.0 = 1), the second stage notch filter frequency
(Pn 40C) will automatically be updated.
Notes:
• If the first stage or the second stage notch filter frequency has already been set (Pn408 = n. 1 1), the notch filter frequency cannot be set.
• If the frequency detected by this function is not used, set the notch filter to be invalid (Pn408.0 =
0).
9
B B − F U N C T I O N −
F n 2 0 5 : V i b S u p
F n 2 0 6 : E a s y F F T
F n 2 0 7 : V - M o n i t o r
F n 0 0 0 : A l m H i s t o r y
Press the Key.
The servomotor enters a baseblocked status. The display returns to the main menu of the utility function.
10 To enable the change in the setting, turn the power OFF and ON again.
6
6-35
6-36
6 Utility Functions (Fn )
(3) Related Parameters
The following table lists parameters related to this function and their possibility of being changed while executing this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes : Parameters can be changed using SigmaWin+ while this function is being executed.
No : Parameters cannot be changed using SigmaWin+ while this function is being executed.
• Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
Parameter
Pn408
Pn409
Pn40A
Pn40C
Pn40D
Pn456
Name
Torque Related Function Switch
1st Notch Filter Frequency
1st Notch Filter Q Value
2nd Notch Filter Frequency
2nd Notch Filter Q Value
Sweep Torque Reference Amplitude
Mid-execution changes
Yes
No
No
No
No
No
Automatic changes
Yes
Yes
No
Yes
No
No
6.22 Online Vibration Monitor (Fn207)
6.22
Online Vibration Monitor (Fn207)
If vibration is generated during operation and this function is executed while the servomotor power is still ON, the machine vibration can sometimes be suppressed by setting a notch filter or torque reference filter for the vibration frequencies.
When online, vibration frequency caused by machine resonance will be detected and the frequency that has the highest peak will be displayed on the panel operator. The effective torque reference filter or notch filter frequency for the vibration frequencies will be automatically selected and the related parameters will be automatically set.
In addition to this function, EasyFFT (Fn206) can be used to detect machine vibration and automatically make notch filter settings. Use the following flowchart to determine how these functions should be used.
If a Σ -V large-capacity SERVOPACK is used to make adjustments, it is recommended that you use advanced autotuning. This built-in function is used to maintain interchangeability with previous models. There is normally no need to use it.
How to use EasyFFT (Fn206) and online vibration monitor (Fn207), when they are mainly used for servo gain adjustment.
Start
Vibration with high-frequency noise
during operation
Yes
Turn OFF the servomotor power, and execute EasyFFT (Fn206)
No
Adjust servo gain
No
Vibration
Yes
With the servomotor power ON, execute online vibration monitor (Fn207)
End
(1) Preparation
The following conditions must be met to perform online vibration monitoring.
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
• The servomotor power must be ON.
• There must be no overtravel.
• The correct moment of inertia (Pn103) must be set.
• The test without a motor function must be disabled (Pn00C.0 = 0).
6
6-37
6-38
6 Utility Functions (Fn )
(2) Operating Procedure
Use the following procedure.
Step
1
2
Display after Operation
R U N − F U N C T I O N −
F n 2 0 6 : E a s y F F T
F n 2 0 7 : V − M o n i t o r
F n 0 0 0 : A l m H i s t o r y
F n 0 0 1 : J O G
R U N − V − M O N I T O R −
M e a s u r e
F 1 = − − − −
F 2 = − − − −
F 3 = − − − −
3
R U N − V − M O N I T O R −
M e a s u r e
F 1 = − − − −
F 2 = − − − −
F 3 = − − − −
4
R U N − V − M O N I T O R −
M e a s u r e
F 1 = 0 8 5 0 [ H z ]
F 2 = 1 6 0 0 [ H z ]
F 3 = 0 2 2 5 [ H z ]
5
D O N E − V − M O N I T O R −
S E T T I N G D O N E
F 1 = 0 8 5 0 [ H z ]
F 2 = 1 6 0 0 [ H z ]
F 3 = 0 2 2 5 [ H z ]
6
R U N − F U N C T I O N −
F n 2 0 6 : E a s y F F T
F n 2 0 7 : V − M o n i t o r
F n 0 0 0 : A l m H i s t o r y
F n 0 0 1 : J O G
Keys Operation
Press the Key to view the main menu for the utility function.
Use the or select Fn207.
Key to move through the list and
Press the Key.
The display changes to the Fn207 execution display.
Press the Key for at least one second to start vibration detection. The Key must be pressed until "Measure" flashes on the display. After this message appears, the Key does not have to be pressed and the detection continues automatically.
When the vibration detection has completed, "Measure" stops flashing and the detection processing ends automatically. When the detection processing has completed normally, the vibrations with three largest peak values in vibration frequency are displayed for
F1, F2, and F3.
Notes:
• Press the Key to quit the online vibration monitor function. The display returns to the main menu of the utility function.
• A detected frequency can be displayed. For a vibration with undetectable peak frequency, "----" is displayed. If no frequency was detected, "----" is displayed for F1, F2, and F3.
• If the frequency could not be successfully detected,
"NO MONITOR" is displayed.
After the detection has normally completed, press the
Key. The optimum frequency (time constant) of notch filter or torque reference filter for F1 is set automatically. At the same time, the parameter Pn409 is updated for a notch filter, or the parameter Pn401 is updated for a torque reference filter.
After the setting is successfully completed, "DONE" flashes.
Press the Key.
The display returns to the main menu of the utility function.
6.22 Online Vibration Monitor (Fn207)
(3) Related Parameters
The following table lists parameters related to this function and their possibility of being changed while executing this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes : Parameters can be changed using SigmaWin+ while this function is being executed.
No : Parameters cannot be changed using SigmaWin+ while this function is being executed.
• Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
Parameter
Pn401
Pn408
Pn409
Pn40A
Pn40C
Pn40D
Name
Torque Reference Filter Time Constant
Torque Related Function Switch
1st Notch Filter Frequency
1st Notch Filter Q Value
2nd Notch Filter Frequency
2nd Notch Filter Q Value
Mid-execution changes
No
Yes
No
No
No
No
Automatic changes
Yes
Yes
Yes
No
No
No
6
6-39
Monitor Displays (Un
7
)
7.1 List of Monitor Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
7.2 Viewing Monitor Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3
7.3 Monitoring Input Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4
7.3.1 Interpreting Input Signal Display Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4
7.3.2 Input Signal Display Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-5
7.4 Monitoring Output Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6
7.4.1 Interpreting Output Signal Display Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6
7.4.2 Output Signal Display Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6
7.5 Monitoring Safety Input Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7
7.5.1 Interpreting Safety Input Signal Display Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7
7.5.2 Safety Input Signal Display Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7
7
7-1
7 Monitor Displays (Un )
7.1
List of Monitor Displays
The monitor displays can be used for monitoring the I/O signal status, and SERVOPACK internal status.
Refer to the following table.
7-2
∗1.
For details, refer to 7.3 Monitoring Input Signals .
∗2.
For details, refer to 7.4 Monitoring Output Signals .
∗3.
For details, refer to 4.4.3 Electronic Gear .
∗4.
For details, refer to 8.3.3 Setting Encoder Output Pulses (PAO, PBO, and PCO) .
7.2 Viewing Monitor Displays
7.2
Viewing Monitor Displays
The monitor display can be checked or viewed in the Parameter/Monitor (-PRM/MON-) window of the digital operator.
The following figure shows four factory settings that are first displayed if viewing monitor displays.
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙
㨁㨚㧜㧜㧜㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧞㧩ޓ㧜㧜㧜㧜㧜
Indicates that the value of Un000
(motor rotating speed) is 0 min
-1
.
㨁㨚㧜㧜㧤㧩ޓ㧜㧜㧜㧜㧜
㨁㨚㧜㧜㧰㧩㧜㧜㧜㧜㧜㧜㧜㧜
MECHA
To view any items that are not shown, press the or Key to scroll through the list.
Motor rotating speed U n 0 0 0 = 0 0 0 0 0 MECHA
Speed reference U n 0 0 1 = 0 0 0 0 0
Internal torque reference U n 0 0 2 = 0 0 0 0 0
Rotational angle 1 (encoder pulses from the phase-C origin) U n 0 0 3 = 0 0 0 0 0
Rotation angle 2 (from polarity origin (electric angle)) U n 0 0 4 = 0 0 0 9 0
Feedback pulse counter U n 0 0 D = 0 0 0 0 0 0 0 0
7
7-3
7-4
7 Monitor Displays (Un )
7.3.1 Interpreting Input Signal Display Status
7.3
Monitoring Input Signals
The status of input signals can be checked with the input signal monitor (Un005). The procedure for the method of interpreting the display and a display example are shown below.
7.3.1
Interpreting Input Signal Display Status
The input signal monitor (Un005) can be read in the following way. The upper level indicates OFF, and the lower level indicates ON. All undefined digits are shown in the lower level (ON).
U n 0 0 5 =
MECHA
8 7 6 5 4 3 2 1 digit
Note: The monitor display and the number of digits shown in a large-capacity Σ -V SERVOPACK are different from those for a standard Σ -V SERVOPACK. Make sure you are reading the displays correctly when checking signal operation.
Display LED
Number
1
4
5
2
3
6
7
8
Input Terminal Name
CN1-40
CN1-41
CN1-42
CN1-43
CN1-44
CN1-45
CN1-46
–
Note: Input signals use the following circuit configuration.
• OFF: Open
• ON: Short-circuited
Example
Signal Name
(Factory Setting)
SI0
/DEC
P-OT
N-OT
/EXT1
/EXT2
/EXT3
Reserved
OFF (open)
7.3.2
Input Signal Display Example
Input signals are displayed as shown below.
• When the /DEC signal is ON
U n 0 0 5 =
The second digit is in the lower level.
MECHA
8 7 6 5 4 3 2 1 digit
• When the /DEC signal is OFF
The second digit is in the upper level.
MECHA
U n 0 0 5 =
8 7 6 5 4 3 2 1 digit
• When the P-OT signal is activated
The third digit is in the upper level.
MECHA
U n 0 0 5 =
8 7 6 5 4 3 2 1 digit
7.3 Monitoring Input Signals
7
7-5
7-6
7 Monitor Displays (Un )
7.4.1 Interpreting Output Signal Display Status
7.4
Monitoring Output Signals
The status of output signals can be checked with the output signal monitor (Un006). The procedure for the method of interpreting the display and a display example are shown below.
7.4.1
Interpreting Output Signal Display Status
The output signal monitor (Un006) can be read in the following way. The upper level indicates OFF, and the lower level indicates ON. All undefined digits are shown in the lower level (ON).
U n 0 0 6 =
8 7 6 5 4 3 2 1 digit
MECHA
Display LED
Number
7
8
5
6
3
4
1
2
Output Terminal Name
CN1-31, -32
CN1-25, -26
CN1-27, -28
CN1-29, -30
−
−
−
−
Note: Output signals use the following circuit configuration.
• OFF: Transistor OFF
• ON: Transistor ON
Example
Signal Name
(Factory Setting)
ALM
/BK
SO2
SO3
Reserved
Reserved
Reserved
Reserved
ON: Transistor ON
7.4.2
Output Signal Display Example
Output signals are displayed as shown below.
• When the ALM signal is OFF
U n 0 0 6 =
The first digit is in the upper level.
MECHA
8 7 6 5 4 3 2 1 digit
7.5 Monitoring Safety Input Signals
7.5
Monitoring Safety Input Signals
The status of safety input signals can be checked with the safety I/O signal monitor (Un015). The procedure for the method of interpreting the display and a display example are shown below.
7.5.1
Interpreting Safety Input Signal Display Status
The safety I/O signal monitor (Un015) can be read in the following way. The upper level indicates ON, and the lower level indicates OFF. All undefined digits are shown in the lower level (OFF).
U n 0 1 5 =
8 7 6 5 4 3 2 1 digit
MECHA
Display LED Number
1
2
3
4
5
6
7
8
Input Terminal Name
CN8-3, -4
CN8-5, -6
−
−
−
−
−
−
Note: Input signals use the following circuit configuration.
• OFF: Open
• ON: Short-circuited
Example
Signal Name
/HWBB1
/HWBB2
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
ON (short-circuited)
7.5.2
Safety Input Signal Display Example
Safety input signals are displayed as shown below.
• When the /HWBB1 signal turns OFF to activate the HWBB function
The first digit is in the lower level.
MECHA
U n 0 1 5 =
8 7 6 5 4 3 2 1 digit
7
7-7
8
Fully-closed Loop Control
8.1 System Configuration and Connection Example for
SERVOPACK with Fully-closed Loop Control . . . . . . . . . . . . . . . . . . . . . 8-2
8.1.1 System Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
8.1.2 Internal Block Diagram of Fully-closed Loop Control . . . . . . . . . . . . . . . . . . . . . . . . . 8-3
8.1.3 Serial Converter Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-4
8.1.4 Example of Connections to External Encoders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6
8.1.5 Encoder Output Pulse Signals from SERVOPACK with an External Encoder by Renishaw plc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-7
8.1.6 Precautions When Using an External Incremental Encoder by Magnescale . . . . . . . 8-8
8.2 SERVOPACK and Converter Startup Procedure . . . . . . . . . . . . . . . . . . 8-12
8.3 Parameter Settings for Fully-closed Loop Control . . . . . . . . . . . . . . . . . 8-14
8.3.1 Motor Rotation Direction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-15
8.3.2 Sine Wave Pitch (Frequency) for an External Encoder . . . . . . . . . . . . . . . . . . . . . . . 8-17
8.3.3 Setting Encoder Output Pulses (PAO, PBO, and PCO) . . . . . . . . . . . . . . . . . . . . . . 8-17
8.3.4 External Absolute Encoder Data Reception Sequence . . . . . . . . . . . . . . . . . . . . . . . 8-18
8.3.5 Electronic Gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-21
8.3.6 Alarm Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-22
8.3.7 Analog Monitor Signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-23
8.3.8 Speed Feedback Method during Fully-closed Loop Control . . . . . . . . . . . . . . . . . . . 8-23
8
8-1
8 Fully-closed Loop Control
8.1.1 System Configuration
8.1
System Configuration and Connection Example for
SERVOPACK with Fully-closed Loop Control
This section describes the system configuration and connection example for the SERVOPACK with fullyclosed loop control.
8.1.1
System Configuration
The following figure shows an example of the system configuration.
SERVOPACK with Fully-closed Module
M-II
8-2
Servomotor main circuit cable
Connection cable for serial converter unit
ޓ
Serial converter unit
Model: JZDP-D00 -000-E
External encoder cable
External encoder
(Not included)
Note 1. The figure above shows a connection example of an external encoder. Refer to 1.6 Examples of Servo System
Configurations for details on the power supply and peripheral devices.
2. In fully-closed loop control, rattling or twisting of mechanical parts may cause vibration, delaying the positioning process.
8.1 System Configuration and Connection Example for SERVOPACK with Fully-closed Loop Control
8.1.2
Internal Block Diagram of Fully-closed Loop Control
Internal block diagram of fully-closed loop control is shown below.
With Position Control
SERVOPACK
MECHATROLINK move command Electronic gear
Error counter
Position control loop
Speed feedback
㧗
㧙
Pn22A
Speed loop
Speed conversion
MECHATROLINK
Monitor data
Encoder output pulse
1
Electronic gear
Unit conversion
Pn20A
Speed conversion
Alarm detection
Divider
Motor
Encoder
A.d10
MECHA
Machine
External encoder ޓ
Serial conversion
Note: Either an incremental or an absolute encoder can be used. When the absolute encoder is used, set 1 to Pn002.2 (use the absolute encoder as an incremental encoder).
With Speed Control
SERVOPACK MECHA
MECHATROLINK move command 㧗
Motor Machine
㧙
Speed loop
Speed feedback
Pn22A Speed conversion
Encoder
MECHATROLINK monitor data 1
Electronic gear Unit conversion
Pn20A Alarm detection
A.d10
External encoder ޓ
Encoder output pulse
Speed conversion
Divider
Serial conversion
8
8-3
8-4
8 Fully-closed Loop Control
8.1.3 Serial Converter Unit
8.1.3
Serial Converter Unit
This section provides the specification of the serial converter unit.
(1) Model: JZDP-D00 -E
Characteristics and Specifications
Electrical
Characteristics
Mechanical
Characteristics
Environmental
Conditions
Items
Power Supply Voltage
Current Consumption
∗ 1
Signal Resolution
Max. Response Frequency
Analog Input Signals
∗ 2
(cos, sin, Ref)
Output Signal
∗ 3
Output Method
Output Circuit
Approx. Mass
Vibration Resistance
Shock Resistance
Surrounding air Temperature
Storage Temperature
Humidity
Altitude
Specifications
+5.0 V ± 5%, ripple content 5% max.
120 mA Typ. 350 mA max.
1/256 pitch (1 cycle) of input 2-phase sine wave pitch
250 kHz
Differential input amplitude: 0.4 V to 1.2 V
Input signal level: 1.5 V to 3.5 V
Position data, alarms
Serial data communications
Balanced type transceiver (SN75LBC176 or the equivalent), internal terminating resistor: 120 Ω
150 g
98 m/s
2
max. (10 to 2500 Hz) in three directions
980 m/s
2
, (11 ms) two times in three directions
0 ° C to 55 ° C
-20 ° C to +80 ° C
20% to 90%RH (without condensation)
1000 m max.
* 1. The current consumption of the external encoder is not included in this value.
The current consumption of the external encoder must be taken into consideration for the current capacity of host controller that supplies the power.
* 2. Input a value within the specified range. Otherwise, incorrect position information is output, and the device may be damaged.
* 3. The transmission is enabled 100 to 300 ms after the power turns ON.
8.1 System Configuration and Connection Example for SERVOPACK with Fully-closed Loop Control
(2) Analog Signal Input Timing
Input the analog signals with the timing shown in the following figure.
The /cos and /sin signals are the differential signals when the cos and sin signals are shifted 180 ° . The specifications of the cos, /cos, sin, and /sin signals are identical except for the phases.
The Ref and /Ref signals are input to the comparator. Input a signal that will exceed the hysteresis of the comparator (i.e., the broken lines in the following figure).
When they are crossed, the output data will be counted up.
100%
*1 cos
(A+)
12.5%
12.5% cos, /cos, sin, and
/sin input voltage range: 1.5 V to 3.5 V
/cos
(A-) sin
(B+)
/sin
(B-)
*2
12.5% min.
12.5% min.
Ref and /Ref input voltage range:
1.5 V to 3.5 V
/Ref
(R-)
Ref
(R+)
75% max.
Zero Point
75% max.
SERVOPACK origin pulse output position
Count-Up Direction
∗1.
If the analog signal amplitude declines to approximately 0.35 V because of the differential amplitude, the serial converter unit will output an alarm.
∗2.
This is the hysteresis width.
• Never perform insulation resistance and withstand voltage tests.
• When low-voltage analog signals are input to the serial converter unit, noise influence on the analog signals affects the unit’s ability to output correct position information.
The analog cable must be as short as possible and shielded.
• Use the serial converter unit in a location without gases such as H
2
S.
• Do not connect or disconnect the unit while power is being supplied, or the unit may be damaged.
• When using multiple axes, use a shielded cable for each axis. Do not use a shielded cable for multiple axes.
• If you use any external encoder other than a recommended external encoder, evaluate the system in advance before you use it.
8
8-5
8-6
8 Fully-closed Loop Control
8.1.4 Example of Connections to External Encoders
8.1.4
Example of Connections to External Encoders
(1) External Encoder by Heidenhain
Model: LIDA 8 , LIF48
SERVOPACK with
Fully-closed Module
Serial converter unit
JZDP-D003-000-E
CN31 CN1 CN2
External encoder by Heidenhain
JZSP-CLP70-E
Model: LIC4100-series Model
SERVOPACK with
Fully-closed Module
CN31
Interface unit by Heidenhain
EIB3391
Connection cable by Heidenhain
External encoder by Heidenhain
Connection cable by Heidenhain
(2) External Encoder by Renishaw plc
SERVOPACK with
Fully-closed Module
CN31
Serial converter unit
JZDP-D005-000-E External encoder by Renishaw plc
CN1 CN2
JZSP-CLP70-E
D-sub 15-pin connector
(3) External Encoder by Mitutoyo Corporation
The serial converter unit is not needed when using the external encoder made by Mitutoyo Corporation.
This external encoder is an absolute encoder.
SERVOPACK with
Fully-closed Module
External encoder by Mitutoyo Corporation
CN31
JZSP-CLP70-E Connection cable by Mitutoyo Corporation
(4) External Encoder by Magnescale Co., Ltd.
Model: SR75, SR85, SR77
∗ 1
, SR87
∗ 1
, RU77
∗ 2
The serial converter unit is not needed when using the external encoder made by Magnescale Co., Ltd.
∗1.
The SR77 and SR87 models are external absolute encoder.
∗2.
The RU77 is rotational external absolute encoder.
SERVOPACK with
Fully-closed Module
External encoder by
Magnescale Co., Ltd.
CN31
Connection cable by Magnescale Co., Ltd.
Model: SL700, SL710, SL720, SL730
SERVOPACK with
Fully-closed Module
Head with interpolator
PL101-RY
CN31
JZSP-CMP 0-E Connection cable by
Magnescale Co., Ltd.
External encoder by
Magnescale Co., Ltd.
8.1 System Configuration and Connection Example for SERVOPACK with Fully-closed Loop Control
8.1.5
Encoder Output Pulse Signals from SERVOPACK with an External Encoder by Renishaw plc
The output position of the zero point signal (Ref) will depend on the direction of movement for some models of external encoders by Renishaw plc.
In such case, the phase-C pulses of the SERVOPACK are output at two positions.
For details on the specifications of the zero-point signals for a external encoder, refer to the manual for the
Renishaw external encoder.
(1) When Passing 1st Zero Point Signal (Ref) in Forward Direction and Returning after
Power ON
Machine position
Phase-C detection position
Phase-C detection position
Power ON
Zero point signal
㧔 Ref 㧕
Time
Phase C
No zero point signal (Ref) is sent from the external encoder.
However, a phase-C pulse will be sent from the SERVOPACK when moving in the reverse direction, because it is the same position from which a phase-C pulse was sent from the
SERVOPACK when moving in a forward direction.
Second pulse is half as wide as the phase-A pulse.
(2) When Passing 1st Zero Point Signal (Ref) in Reverse Direction and Returning after
Power ON
Machine position
Phase-C detection position
Phase-C detection position
Power ON
Zero point signal
㧔 Ref 㧕
Time
Phase C
No zero point signal (Ref) is sent from the external encoder.
However, a phase-C pulse will be sent from the SERVOPACK when moving in the forward direction, because it is the same position from which a phase-C pulse was sent from the
SERVOPACK when moving in a reverse direction.
Second pulse is half as wide as the phase-A pulse.
8
8-7
8-8
8 Fully-closed Loop Control
8.1.6 Precautions When Using an External Incremental Encoder by Magnescale
8.1.6
Precautions When Using an External Incremental Encoder by Magnescale
When an external incremental encoder by Magnescale Co., Ltd. is used, the count direction of the encoder determines if a phase-C pulse (CN1-19, CN1-20) is output and counted.
Note: The count direction (counting up or down) of the encoder determines if a phase-C pulse is output. The output of the pulse does not depend on the settings of these parameters: Pn000.0 (motor rotational direction ) and Pn002.3 (external encoder usage method).
Model
SL710
SL720
SL730
SR75
SR85
Interpolator
PL101-RY
Scale pitch ( μ m)
800
800
800
80
80
When Passing 1st Zero Point in Forward Direction and Returning after Power ON
After the power is turned on, the phase-C pulse (CN1-19, CN1-20) is output when the external encoder moves forward and its detection head first passes the phase-C detection position. After the detection head of the encoder passes the detection position in a forward direction, the phase-C pulse is output when the head passes the position regardless of the direction of the encoder’s movement.
Rotation
Scale count-up direction
Phase-C detection position
Power ON
Time
Phase-C pulse output
The phase-C pulse is also output when the detection head of the encoder passes this point in reverse, because the SERVOPACK has recorded the position where the phase-C pulse was originally output when first passing the position in the forward direction.
8.1 System Configuration and Connection Example for SERVOPACK with Fully-closed Loop Control
When Passing 1st Zero Point in Reverse Direction and Returning after Power ON
After the power is turned on, the phase-C pulse (CN1-19, CN1-20) is not output when the external encoder moves reverse and its head first passes the phase-C detection position. The phase-C pulse is output for the first time when the external encoder moves forward and its head passes the detection position. After the detection head of the encoder first passes the detection position in the forward direction, the phase-C pulse is output when the head passes the position regardless of the direction of the encoder’s movement.
Scale count-up direction
Rotation
Phase-C detection position
Power ON
Phase-C pulse output
The phase-C pulse is not output when passing the detection position in reverse direction first.
Time
The phase-C pulse is also output when passing this point in reverse, because the SERVOPACK has recorded the position where the phase-C pulse was originally output when first passing the position in the forward direction.
8
8-9
8-10
8 Fully-closed Loop Control
8.1.6 Precautions When Using an External Incremental Encoder by Magnescale
When Using an External Encoder with Multiple Zero Points and Passing 1st
Forward Direction and Returning after Power ON
Zero Point in
When using an external encoder with multiple zero points, the same logic as that explained earlier for an encoder with only one zero point applies to each zero point.
See When Passing 1st Zero Point in Forward Direction and Returning after Power ON.
Scale count-up direction
Zero point 1 detection position
Zero point 2 detection position
Power ON
Time
Phase-C pulse output
Zero point 1 Zero point 1 Zero point 2 Zero point 2
The phase-C pulse is also output when passing this point in reverse, because the SERVOPACK has recorded the position where the phase-C pulse was originally output when first passing the position in the forward direction.
Even after zero point 1 has first been passed in the forward direction, the phase-C pulse is not output here because zero point 2 is passed in reverse direction.
When Using an External Encoder with Multiple Zero Points and Passing 1st
Reverse Direction and Returning after Power ON
Zero Point in
When using an external encoder with multiple zero points, the same logic as that explained earlier for an encoder with only one zero point applies to each zero point.
See When Passing 1st Zero Point in Reverse Direction and Returning after Power ON .
Scale count-up direction
Zero point 1 detection position
Zero point 2 detection position
Zero point 3 detection position
Time
Power ON
Phase-C pulse output
Zero point 1 Zero point 3 Zero point 3
Phase-C pulse is not output when passing a zero point in reverse direction.
To output the phase-C pulse when a detection point is passed in reverse, set the following parameter to 1.
Pn081
Parameter n.
0
[Factory Setting] n.
1
Meaning
Outputs phase-C pulse only in forward direction.
Outputs phase-C pulse in forward and reverse direction.
When Enabled
After restart
Classification
Setup
8.1 System Configuration and Connection Example for SERVOPACK with Fully-closed Loop Control
• Setting of Pn081.0
Do not change the factory setting if the zero point position of the existing equipment must remain as is.
• When Pn081.0 = 1, the width of the phase-C pulse output is narrower than that of the phase-A pulse in some cases.
• As shown in the following figure, there is a one-eighth scale pitch difference in positions between the two settings (Pn081.0 = 1 and Pn081.0 = 0) for the phase-C pulse output, the zero point return command, and the phase-C detection by phase-
C latch function.
Moves to forward
1 scale pitch
Pn081.0 = 0
Zero point
1/8 scale pitch
Pn081.0 = 1
Zero point
8
8-11
8 Fully-closed Loop Control
8.2
SERVOPACK and Converter Startup Procedure
First check that the SERVOPACK and converter operate correctly with semi-closed loop control, then check that they operate correctly with fully-closed loop control.
The following describes the startup procedure for the SERVOPACK in fully-closed loop control.
8-12
Procedure
1
2
3
Description Operation
Check operation of the whole sequence in semi-closed loop control and without any load.
Items to Check
• Power supply circuit wiring
• Servomotor wiring
• Encoder wiring
• Wiring of I/O signal lines from the host controller
• Servomotor rotation direction, speed, and number of rotations
• Operation of safety mechanisms, such as the brakes and the overtravel mechanism
Check operation of the system connected with the machine and servomotor in semi-closed loop control mode.
Set the parameters so that the SER-
VOPACK operates correctly in semi-closed loop control (Pn002.3
= 0) without any load and check the following points.
• Is there an error with the SER-
VOPACK or converter?
• Does the JOG operation operate correctly when operating the
SERVOPACK in standalone mode?
• Do the I/O signals turn ON/OFF correctly?
• Does the servomotor turn ON when the SV_ON command is sent from the host controller?
• Does the servomotor operate correctly when the position reference is input by the host controller?
Connect the servomotor to the machine.
Set the moment of inertia ratio
(Pn103) using the advanced autotuning function.
Check that the machine operates in the correct direction, distance, and speed as directed by the host controller.
Items to Check
• Initial responsiveness of the system connected with the machine
• Movement direction, distance, and speed of the machine specified by the host controller
Check the external encoder.
Item to Check
• Are signals from the external encoder received correctly?
Set parameters related to the fullyclosed loop control and move the machine with your hand without turning ON the power supply to the servomotor. Check the following status with the digital operator or
SigmaWin+.
• Does the fully-closed feedback pulse counter (Un00E) count up when the servomotor moves in the forward direction?
• Is the distance the machine moved about visually the same as the amount counted by the fully-closed feedback pulse counter (Un00E)?
Note: The unit for fully-closed feedback pulse counter
(Un00E) is one pulse, which is equivalent to the external encoder sine wave pitch divided by the number of divisions
*
.
∗ Refer to 8.3.5 Electronic Gear for details on the number of divisions.
Parameters Requiring
Settings
• Basic Function Select Switch
0 (Pn000)
• Application Function Select
Switch 1 (Pn001)
• External Encoder Usage
(Pn002.3)
• Electronic Gear Ratio
(Numerator) (Pn20E)
• Electronic Gear Ratio
(Denominator) (Pn210)
• Input Signal Selection
(Pn50A, Pn50B, Pn511)
• Output Signal Selection
(Pn50E, Pn50F, Pn510)
• Moment of inertia ratio
(Pn103)
• External Encoder Usage
(Pn002.3)
• Number of External Scale
Pitch (Pn20A)
• Electronic Gear Ratio
(Numerator) (Pn20E)
• Electronic Gear Ratio
(Denominator) (Pn210)
• Encoder Output Resolution
(Pn281)
• Excessive Error Level
Between Servomotor and
Load Positions (Pn51B)
• Positioning Completed
Width (Pn522)
• Multiplier per One Fullyclosed Rotation (Pn52A)
Controller
SERVOPACK or host controller
Host controller
−
8.2 SERVOPACK and Converter Startup Procedure
(cont’d)
Procedure
4
5
Description Operation
Perform a program JOG operation.
Items to Check
• Does the fully-closed loop control operate correctly when operating the SERVOPACK in standalone mode?
Operate the SERVOPACK and converter.
Items to Check
• Does the fully-closed loop control operate correctly including the host controller?
Perform a program JOG operation and check that the distance that the servomotor moved is the same as the distance that is set in Pn531.
Note: Start from a low speed and gradually increase the speed.
Input the position reference and check that the SERVOPACK and converter operate correctly.
Note: Start from a low speed and gradually increase the speed.
Parameters Requiring
Settings
• Program JOG related parameters (Pn530 to Pn536)
−
Controller
SERVOPACK
Host controller
8
8-13
8-14
8 Fully-closed Loop Control
8.3
Parameter Settings for Fully-closed Loop Control
This section describes the parameter settings for fully-closed loop control.
Set Parameters Setting Contents
Position
Control
Speed
Control
Torque
Control
Reference
Pn000.0
Pn002.3
Pn20A
Pn281
−
Pn20E, Pn210
Pn51B
Pn52A
Pn006/Pn007
Pn22A
Motor rotation direction
External encoder usage method
Number of pitches for the external encoder
Number of encoder output pulses
(PAO, PBO, and PCO) from the
SERVOPACK
External absolute encoder data reception sequence
Electronic gear ratio
Excessive error level between servomotor and load positions
Multiplier per one fully-closed rotation
Analog monitor signal
Speed feedback method during fullyclosed loop control
−
−
−
−
−
−
−
−
8.3.1
8.3.2
8.3.3
8.3.4
8.3.5
8.3.6
8.3.7
8.3.8
Note: When using an external absolute encoder, this external encoder works as an absolute encoder even if Pn002.2 is set to 1.
Parameter Meaning
When
Enabled
Classification
Pn002 n. 0
[Factory setting] n. 1
Uses the absolute encoder as an absolute encoder.
Uses the absolute encoder as an incremental encoder.
After restart Setup
8.3 Parameter Settings for Fully-closed Loop Control
8.3.1
Motor Rotation Direction
The motor rotation direction can be set. To perform fully-closed loop control, it is necessary to set the motor rotation direction with both Pn000.0 (motor rotation direction) and Pn002.3 (external encoder usage).
(1) Setting Parameter Pn000.0
The standard setting for forward rotation is counterclockwise (CCW) as viewed from the load end of the servomotor.
Parameter
Forward/
Reverse
Reference
Direction of Motor Rotation and Encoder Output Pulse
Applicable
Overtravel
(OT)
Forward
Reference
CCW
Motor speed
+ Torque reference
Encoder output pulse
Motor speed
Time
PAO
PBO Phase B advanced
P-OT n.
0
Sets CCW as forward direction.
[Factory setting]
Reverse
Reference
CW
+ Motor speed
Torque reference
Time
Encoder output pulse
PAO
Motor speed
PBO
Phase A advanced
N-OT
Pn000 n.
1
Sets CW as forward direction.
(Reverse Rotation
Mode)
Forward
Reference
CW
+
Motor speed
Torque reference
Encoder output pulse
Motor speed
Time
PAO
PBO Phase B advanced
P-OT
Reverse
Reference
CCW
+ Motor speed
Torque reference
Encoder output pulse
PAO
Time
PBO
Phase A advanced
Motor speed
N-OT
Note: SigmaWin+ trace waveforms are shown in the above table.
(2) Setting Parameter Pn002.3
Pn002
Parameter Name Meaning
When
Enabled n.0
[Factory setting]
Do not use external encoder.
* n.1
n.2
n.3
n.4
External Encoder
Usage
Uses external encoder in standard rotation direction.
Reserved (Do not set.)
Uses external encoder in reverse rotation direction.
Reserved (Do not set.)
∗ The mode will be switched to semi-closed position control if Pn002 is set to n.0
.
After restart
Classification
Setup
8
8-15
8-16
8 Fully-closed Loop Control
8.3.1 Motor Rotation Direction
(3) Relation between Motor Rotation Direction and External Encoder Pulse Phases
Refer to the table below.
Parameter
0
Reference direction
Motor rotation direction
External encoder output
Forward reference
CCW cos lead
Pn002.3 (External Encoder Usage)
1 3
Reverse reference
Forward reference
CW sin lead
CCW sin lead
Reverse reference
CW cos lead
Pn000.0
(Motor rotation direction)
1
Encoder output pulse
Reference direction
Motor rotation direction
External encoder output
Phase B
lead
Forward reference
CW sin lead
Phase A lead
Reverse reference
CCW cos lead
Phase B lead
Forward reference
CW cos lead
Phase A lead
Reverse reference
CCW sin lead
Encoder output pulse
Phase B lead
Phase A lead
Phase B lead
Phase A lead
• Set Pn002 to n.1
(forward rotation with forward reference) if the output of the external encoder is cos lead and the motor is turning counterclockwise; set Pn002 to n.3
ence) if it is sin lead. When Pn000 is set to n.
counterclockwise. If the fully-closed feedback pulse counter (Un00E) counts up, set Pn002 to n.1
the Un00E counts down, set Pn002 to n.3
.
0 and Pn002 to n.1
(reverse rotation with forward refer-
, manually turn the motor shaft
. If
• The output pulses are phase-B advanced if the motor is turning forward regardless of the setting in Pn000.0.
8.3 Parameter Settings for Fully-closed Loop Control
8.3.2
Sine Wave Pitch (Frequency) for an External Encoder
Set the number of external encoder pitches per motor rotation to Pn20A.
Pn20A is the speed conversion coefficient when the external encoder is used as speed feedback.
(1) Setting Example
Specifications
External encoder sine wave pitch: 20 μ m
Ball screw lead: 30 mm
If the external encoder is connected directly to the motor, the set value will be 1500 (30 mm/0.02 mm = 1500).
Note 1. If there is a fraction, round off the digits below the decimal point.
2. If the number of external encoder pitches per motor rotation is not an integer, there is some error in the speed loop. This is not relevant for the position loop however, therefore it does not interfere with the position accuracy.
(2) Related Parameter
Pn20A
Number of External Scale Pitch
Setting Range
4 to 1048576
Setting Unit
1 pitch/rev
Position
Factory Setting
32768
When Enabled
After restart
Classification
Setup
8.3.3
Setting Encoder Output Pulses (PAO, PBO, and PCO)
Set the position resolution to Pn281. Set the number of phase A and phase B edges.
(1) Setting Example
Specifications
External encoder sine wave pitch: 20 μ m
Ball screw lead: 30 mm
Speed: 1600 mm/s
If the output of a single pulse (multiplied by 4) is 1 μ m, the set value will be 20.
If the output of a single pulse (multiplied by 4) is 0.5 μ m, the set value will be 40.
The encoder output pulse will have the following waveform if the set value is 20.
Phase A
Rotation
Phase B
Sine wave pitch
" ↑ " shows the edge position. In this example, the set value is 20 therefore the number of ↑ is 20.
Note: The upper limit of the encoder signal output frequency (multiplied by 4) is 6.4 Mpps. Do not set a value that would cause the output to exceed 6.4 Mpps. If the output exceeds the upper limit, the overspeed of encoder output pulse rate alarm (A.511) will be output.
Example:
The frequency is as follows if the set value is 20 and the speed is 1600 mm/s:
1600 mm/s
0.001 mm
= 1600000 = 1.6 Mpps
Because 1.6 Mpps is less than 6.4 Mpps, this value can be used.
8
8-17
8-18
8 Fully-closed Loop Control
8.3.4 External Absolute Encoder Data Reception Sequence
(2) Related Parameter
Pn281
Encoder Output Resolution
Setting Range
1 to 4096
Setting Unit
1 edge/pitch
Position
Factory Setting
20
Classification
When Enabled
After restart Setup
Note: The maximum setting for the encoder output resolution is 4096. When the number of divisions on the external encoder is more than 4096, the data shown in 8.3.5
External Encoder Sine Wave Pitch and Number of Divisions is no longer applicable.
(3) Phase-C Pulse Output Specifications
The pulse width of phase C (origin pulse) varies according to the encoder output resolution (Pn281), and will become the same as the pulse width of phase A.
Output timing for the phase-C pulse is one of the following.
• In synchronization with the phase-A rising edge
• In synchronization with the phase-A falling edge
• In synchronization with the phase-B rising edge
• In synchronization with the phase-B falling edge
Phase C of the rotational external absolute encoder is output only at the encoder’s first point of origin after the power is supplied. Phase C of the external encoder is not output every rotation.
8.3.4
External Absolute Encoder Data Reception Sequence
The sequence in which the SERVOPACK receives outputs from the external absolute encoder and transmits them to host controller in fully-closed loop control is shown below.
(1) Outline of Absolute Signals
The serial data, pulses, etc., of the external absolute encoder that are output from the SERVOPACK are output from the PAO, PBO, and PCO signals as shown below.
Host controller SERVOPACK with Fully-closed Module
CN1 CN31
MECHA
PAO
PBO
PCO
Dividing circuit
(Pn281)
Serial data → pulse conversion
Serial data External encoder
Signal Name
PAO
PBO
Status
At initialization
Contents
Serial data
Initial incremental pulses
Normal Operations Incremental pulses
At initialization Initial incremental pulses
Normal Operations Incremental pulses
Always Origin pulses PCO
Note: When host controller receives the data from the external absolute encoder, do not perform counter reset using the output of PCO signal.
8.3 Parameter Settings for Fully-closed Loop Control
(2) Absolute Data Transmission Sequence and Contents
1. Send the Turn Encoder Power Supply ON (SENS_ON) command from the host controller.
2. After 100 ms, set the system to serial data reception-waiting-state. Clear the incremental pulse up/down counter to zero.
3. Receive eight characters of serial data.
4. The system enters a normal incremental operation state about 400 ms after the last serial data is received.
SENS_ON
(Turn Encoder
Power Supply ON)
M-II
Serial data
PAO
PBO
Undefined
Undefined
Initial incremental pulses
(Phase A) (Phase A)
Incremental pulses
Initial incremental pulses
Incremental pulses
(Phase B) (Phase B) 60 ms min.
90 ms typ.
50 ms About 15 ms 400 ms max.
1 to 3 ms
Serial data:
The current position pulses divided by Pn281 are output in serial data.
One serial data is a value equivalent to 1048576 pulses.
Initial incremental pulses:
The current position pulses divided by Pn281 are output in pulses. The number of output pulses is between 0 to 1048576, and the output speed is approximately 1.48 µs per pulse.
Coordinate value
Values of
Mo and Ms
Reference position (at setup) Current position
0 1 2 3
Rotation
M o
×
R
P
O
3 (Mo)
P
E
M
S
×
R P
S
P
M
Final absolute data P
M
is calculated by following formula.
P
E
= M
O
× R + P
O
P
M
= P
E
– M
S
× R – P
S
Signal
P
M
P
M
E
O
O
S
P
S
P
M
R
Meaning
Current position of external encoder
Serial data of current position
Number of initial incremental pulses of current position
Serial data of reference position
Number of initial incremental pulses of reference position
Current value required for the user’s system
1048576
Note: If host controller receives the data from the external absolute encoder, do not perform counter reset using the output of PCO signal.
8
8-19
8-20
8 Fully-closed Loop Control
8.3.4 External Absolute Encoder Data Reception Sequence
(3) Serial Data Specifications
The serial data is output from the PAO signal.
Data Transfer
Method
Baud rate
Start bits
Stop bits
Parity
Character code
Data format
Start-stop Synchronization (ASYNC)
9600 bps
1 bit
1 bit
Even
ASCII 7-bit code
8 characters, as shown below.
"P"
"+" or " - "
"0" to "9" serial data in five digits
"CR"
0 0 0 0 0 1 0 1 0 1
Data
Start bit
Stop bit
Even parity
Note: 1. Data is "P+00000" (CR) or "P-00000" (CR) when the position is zero.
2. The serial data range is "-32768" to "+32767". When this range is exceeded, the data changes from "+32767" to "-32678" or from "-32768" to "+32767." When changing multiturn limit, the range changes. For details, refer to 4.7.6 Multiturn Limit Setting .
(4) Transferring Alarm Contents
If an external absolute encoder is used, the contents of alarms detected by the SERVOPACK are transmitted in serial data to the host controller from the PAO output when the Turn Encoder Power Supply OFF command
(SENS_OFF) is received.
Note: The SENS_OFF command cannot be received while the servomotor power is ON.
Output example of alarm contents are as shown below.
Turn Encoder
Power Supply
OFF
(SENS_OFF)
High level Error detection
Encoder power supply ON
Encoder power supply OFF
M-II
Panel Display or
Overspeed
Incremental pulse
PAO Output
Enlarged view
Data Format
Serial Data
“A” “L” “M” “5” “1” “.” “CR”
Upper 2 digits
8.3 Parameter Settings for Fully-closed Loop Control
8.3.5
Electronic Gear
Refer to 4.4.3 Electronic Gear for the purpose of setting the electronic gear.
The following formula is used to calculate the electronic gear ratio in fully-closed loop control.
Electronic gear ratio
B
A
==
Pn20E
Pn210
=
Travel distance per reference unit × Number of divisions
External encoder sine wave pitch Rotation
Note: Set Pn20E (numerator B) and Pn210 (denominator A) to integral values.
The setting range is defined by 0.001 ≤ ≤ 4000.
The following table shows the various external encoder sin wave pitches and the number of divisions.
External Encoder Sine Wave Pitch and Number of Divisions
Calculate the electronic gear ratio with the values in the following table.
Type of
External
Encoder
Manufacturer
Heidenhain
External Encoder
Model
LIDA48
LIDA18
LIF48
Incremental
Absolute
Renishaw plc
Magnescale Co., Ltd.
Heidenhain
Mitutoyo Corporation
Magnescale Co., Ltd.
RGH22B
SR75 LF
*2
SR75 MF
SR85 LF
*2
SR85 MF
SL700
*2
, SL710
*2
,
SL720
*2
, SL730
*2
LIC4100
ST781A/ST781AL
ST782A/ST782AL
ST783/ST783AL
ST784/ST784AL
ST788A/ST788AL
ST789A/ST789AL
*5
SR77 LF
*2
SR77 MF
SR87 LF
*2
SR87 MF
RU77-4096ADF
*6
RU77-4096AFFT01
*6
Sine Wave
Pitch [ μ m]
20
40
4
20
Model of Relay
Device between
SERVOPACK and
External Encoder
JZDP-D003 -E
∗ 1
JZDP-D003 -E
∗ 1
JZDP-D003 -E
∗ 1
JZDP-D005 -E
∗ 1
80
80
80
80
–
–
–
–
800
20.48
256
256
51.2
51.2
51.2
25.6
80
80
80
80
–
–
PL101-RY
*3
EIB3391Y
*4
–
–
–
–
–
–
–
–
–
–
–
–
Number of
Divisions
Resolution
256
256
256
256
8192
1024
8192
1024
8192
4096
512
512
512
512
512
512
8192
1024
8192
1024
256
1024
0.005 μ m
0.5 μ m
0.5 μ m
0.1 μ m
0.1 μ m
0.1 μ m
0.05 μ m
0.0098 μ m
0.078 μ m
0.0098 μ m
0.078 μ m
20 bits
22 bits
0.078 μ m
0.156 μ m
0.016 μ m
0.078 μ m
0.0098 μ m
0.078 μ m
0.0098 μ m
0.078 μ m
0.0977 μ m
∗1.
Models for serial converter units.
∗2.
When using the encoder pulse output with these external encoders, the setting range of Pn281 is restricted. For details, refer to 8.3.3 Setting Encoder Output Pulses (PAO, PBO, and PCO) .
∗3.
Model for sensor head with interpolator.
∗4.
Model for interface unit by Heidenhain.
∗5.
For details on this external encoder, contact Mitutoyo.
∗6.
Model for rotational external encoder.
Refer to the manuals for the external encoder and serial converter unit for details on the sine wave pitch and the number of divisions of the external encoder.
8
8-21
8-22
8 Fully-closed Loop Control
8.3.6 Alarm Detection
Setting Example
If the servomotor moves 0.2 μ m for every pulse of position reference, the external encoder sine wave pitch is
20 μ m, and the number of divisions is 256, the electronic gear ratio will be as follow.
Electronic gear ratio
B
A
==
Pn20E
Pn210
=
0.2 × 256
20
=
512
200
Rotation
Therefore, set 512 for Pn20E (numerator B) and 200 for Pn210 (denominator A).
8.3.6
Alarm Detection
The setting of alarm detection (Pn51B/Pn52A) is shown below.
(1) Excessive Error Level between Servomotor and Load Positions (Pn51B)
This setting detects the difference between the feedback position of the motor encoder and the feedback load position of the external encoder in fully-closed loop control. If the detected difference is above the set level, the motor-load position error overflow alarm (A.d10) will be output.
Pn51B
Excessive Error Level between Servomotor and
Load Positions
Setting Range Setting Unit
Position
Factory Setting
0 to 1073741824 1 reference unit 1000
When Enabled
Immediately
Classification
Setup
Note: When Pn51B is set to 0, the motor-load position error overflow alarm (A.d10) is not detected.
(2) Multiplier per One Fully-closed Rotation (Pn52A)
The coefficient of the error between the external encoder and the motor per motor rotation can be set. This function can be used to prevent the motor from running out of control due to damage to the external encoder or to detect slippage of the belt.
Setting Example
Increase the value if the belt slips or is twisted excessively.
If the set value is 0, the external encoder value will be read as it is.
If the factory setting of 20 is used, the second rotation will start with the error for the first motor rotation multiplied by 0.8. (Refer to the following figure.)
Error between motor and external encoder
Big
Pn52A=0
Pn52A=20
Small
Pn52A=100
Number of motor rotations
Less than one rotation
1st rotation
Related Parameter
Pn52A
Multiplier per One Fully-closed Rotation
Setting Range
0 to 100
Setting Unit
1%
2nd rotation
Position
Factory Setting
20
3rd rotation
When Enabled
Immediately
Rotation
Classification
Setup
8.3 Parameter Settings for Fully-closed Loop Control
8.3.7
Analog Monitor Signal
The position error between servomotor and load can be monitored with the analog monitor.
Parameter
Pn006 n.
07
Pn007 n.
07
Name
Analog Monitor 1
Signal Selection
Analog Monitor 2
Signal Selection
Meaning
Position error between servomotor and load
[0.01 V/1 reference unit]
Factory setting: n.
02
Position error between servomotor and load
[0.01 V/1 reference unit]
Factory setting: n.
00
When
Enabled
Immediately
Classification
Setup
8.3.8
Speed Feedback Method during Fully-closed Loop Control
MECHATROLINK
Speed reference
SERVOPACK
Position reference
Electronic gear
Error counter
Motor Machine
MECHATROLINK monitor data
Encoder output pulse
1
Electronic gear
Divider
Position control loop
㧗
㧙
Speed feedback
Pn22A
Speed loop
Unit conversion
Pn20A
Speed conversion
Alarm detection
Speed conversion
ENC
A.d10
External encoder ޓ
Serial conversion MECHA
Use Pn22A.3 to select the speed feedback method during fully-closed loop control: Normally, set Pn22A.3 to
0 (Uses motor encoder speed.).
When Enabled Classification
Pn22A
Parameter n.0
[Factory setting] n.1
Meaning
Uses motor encoder speed.
Uses external encoder speed.
After restart Setup
Note: This parameter cannot be used when Pn002.3 is set to 0.
8
8-23
9
Troubleshooting
9.1 Alarm Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2
9.1.1 List of Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2
9.1.2 Troubleshooting of Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-6
9.2 Warning Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-22
9.2.1 List of Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-22
9.2.2 Troubleshooting of Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-23
9.3 Monitoring Communication Data on Occurrence of an Alarm or Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-27
9.4 Troubleshooting Malfunction Based on Operation and
Conditions of the Servomotor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-28
9
9-1
9 Troubleshooting
9.1.1 List of Alarms
9-2
9.1
Alarm Displays
The following sections describe troubleshooting in response to alarm displays.
The alarm name, alarm meaning, alarm stopping method, and alarm reset capability are listed in order of the alarm numbers in 9.1.1 List of Alarms .
The causes of alarms and troubleshooting methods are provided in 9.1.2 Troubleshooting of Alarms .
9.1.1
List of Alarms
This section provides list of alarms.
Servomotor Stopping Method
If an alarm occurs, the servomotor can be stopped by doing either of the following operations.
Gr.1: The servomotor is stopped according to the setting in Pn001.0 if an alarm occurs. Pn001.0 is factory-set to stop the servomotor by applying the DB.
Gr.2: The servomotor is stopped according to the setting in Pn00B.1 if an alarm occurs. Pn00B.1 is factory-set to stop the servomotor by setting the speed reference to " 0.
" The servomotor under torque control will always use the Gr.1 method to stop. By setting Pn00B.1 to 1, the servomotor stops using the same method as Gr.1. When coordinating a number of servomotors, use this stopping method to prevent machine damage that may result due to differences in the stop method.
Alarm Reset
Available: Removing the cause of alarm and then executing the alarm reset can clear the alarm.
N/A: Executing the alarm reset cannot clear the alarm.
Alarm
Number
Alarm Name Meaning
A.020
Parameter Checksum
Error 1
The data of the parameter in the SERVOPACK is incorrect.
A.021
Parameter Format Error 1 The data of the parameter in the SERVOPACK is incorrect.
A.022
System Checksum Error 1 The data of the parameter in the SERVOPACK is incorrect.
A.030
Main Circuit Detector Error Detection data for main circuit is incorrect.
A.040
Parameter Setting Error 1 The parameter setting is outside the setting range.
A.041
A.042
Encoder Output Pulse
Setting Error
Parameter Combination
Error
The encoder output pulse (Pn212) is outside the setting range or does not satisfy the setting conditions.
Combination of some parameters exceeds the setting range.
A.044
Semi-closed/Fully-closed
Loop Control Parameter
Setting Error
The settings of the option module and Pn00B.3, Pn002.3 do not match.
A.04A
Parameter Setting Error 2 Bank member/bank data setting is incorrect.
A.050
Combination Error
The SERVOPACK and the servomotor capacities do not match each other.
A.051
Unsupported Device Alarm The device unsupported was connected.
A.0b0
A.100
Cancelled Servo ON
Command Alarm
Overcurrent or Heat Sink
Overheated
The servo ON command (SV_ON) was sent from the host controller after executing a utility function that turns ON servomotor.
An overcurrent flowed through the IGBT or the heat sink of the
SERVOPACK was overheated.
A.300
Regeneration Error
A.320
Regenerative Overload
A.330
Main Circuit Power
Supply Wiring Error
A.400
Overvoltage
Regenerative circuit or regenerative resistor is faulty.
Regenerative energy exceeds regenerative resistor capacity.
• Setting of AC input/DC input is incorrect.
• Power supply wiring is incorrect.
Main circuit DC voltage is excessively high.
Servomotor
Stopping
Method
Gr.1
Alarm
Reset
N/A
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.2
Gr.1
Gr.1
N/A
N/A
Available
N/A
N/A
N/A
N/A
N/A
Available
N/A
Available
N/A
Available
Available
Available
Available
9.1 Alarm Displays
Alarm
Number
Alarm Name Meaning
A.410
A.42A
Undervoltage
Converter error
Main circuit DC voltage is excessively low.
One of the following was detected by the converter.
• An operation error occurred when using the limit relay for inrush current
• PN voltage error
• Regeneration operation error
• The converter’s heat sink overheated
• An operation error occurred when using the converter and fan
A.450
Main-Circuit
Capacitor Overvoltage
A.510
Overspeed
A.511
Overspeed of Encoder
Output Pulse Rate
A.520
Vibration Alarm
A.521
Autotuning Alarm
The capacitor of the main circuit has deteriorated or is faulty.
The servomotor speed is above the maximum rotational speed.
The pulse output speed upper limit of the set encoder output pulse
(Pn212) is exceeded.
Incorrect vibration at the motor speed was detected.
A.710
A.720
Overload: High Load
Overload: Low Load
Vibration was detected while performing tuning-less function.
The servomotor was operating for several seconds to several tens of seconds under a torque largely exceeding ratings.
The servomotor was operating continuously under a torque exceeding ratings.
When the dynamic brake was applied, rotational energy exceeded the capacity of dynamic brake resistor.
A.730
A.731
Dynamic Brake Overload
A.740
Overload of Surge
Current Limit Resistor
A.7A0
Heat Sink Overheated
A.7AB
Built-in Fan in
SERVOPACK Stopped
The main circuit power was frequently turned ON and OFF.
The heat sink of the SERVOPACK or converter exceeded 100
The fan inside the SERVOPACK stopped.
° C.
A.810
Encoder Backup Error
The power supplies to the encoder all failed and position data was lost.
A.820
Encoder Checksum Error The checksum results of encoder memory is incorrect.
A.830
Absolute Encoder Battery
Error
A.840
Encoder Data Error
The battery voltage was lower than the specified value after the control power supply was turned ON.
Data in the encoder is incorrect.
A.850
Encoder Overspeed
A.860
Encoder Overheated
A.8A0
External Encoder Error
A.8A1
External Encoder Error of
Module
A.8A2
A.8A3
A.8A5
A.8A6
A.A
*1
External Encoder Error of
Sensor
External Encoder Error of
Position
External Encoder Overspeed
External Encoder Overheated
The encoder was rotating at high speed when the power was turned
ON.
The internal temperature of encoder is too high.
External encoder is faulty.
Serial converter unit is faulty.
External encoder is faulty.
The position data of external encoder is faulty.
The overspeed from the external encoder occurred.
The overheat from the external encoder occurred.
SERVOPACK: Command
Option Module Alarms
−
∗1.
These alarms occur in SERVOPACKs with command option modules.
For details, refer to the manual for the command option module that is connected.
(cont’d)
Servomotor
Stopping
Method
Gr.2
Alarm
Reset
Available
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.2
Gr.1
Gr.1
Gr.1
Gr.2
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
−
Available
N/A
Available
Available
Available
Available
Available
Available
Available
Available
Available
Available
N/A
N/A
Available
N/A
N/A
N/A
Available
Available
Available
Available
Available
Available
−
9
9-3
9-4
9 Troubleshooting
9.1.1 List of Alarms
(cont’d)
Alarm
Number
Alarm Name Meaning
A.b31
Current Detection Error 1 The current detection circuit for phase U is faulty.
A.b32
Current Detection Error 2 The current detection circuit for phase V is faulty.
A.b33
Current Detection Error 3 The detection circuit for the current is faulty.
A.b6A
A.b6b
MECHATROLINK
Communications
ASIC Error 1
MECHATROLINK
Communications
ASIC Error 2
ASIC error occurred in the MECHATROLINK communications.
ASIC error occurred in the MECHATROLINK communications.
A.bF0
A.bF1
A.bF2
A.bF3
System Alarm 0
System Alarm 1
System Alarm 2
System Alarm 3
"Internal program error 0" of the SERVOPACK occurred.
"Internal program error 1" of the SERVOPACK occurred.
"Internal program error 2" of the SERVOPACK occurred.
"Internal program error 3" of the SERVOPACK occurred.
"Internal program error 4" of the SERVOPACK occurred.
The servomotor ran out of control.
A.bF4
System Alarm 4
A.C10
Servo Overrun Detected
A.C80
A.C90
Absolute Encoder Clear
Error and Multiturn Limit
Setting Error
Encoder Communications
Error
The multiturn for the absolute encoder was not properly cleared or set.
A.C91
A.C92
A.CA0
Encoder Parameter Error Encoder parameters are faulty.
A.Cb0
Encoder Echoback Error Contents of communications with encoder are incorrect.
A.CC0
A.CF1
Encoder Communications
Position Data Error
Encoder Communications
Timer Error
Multiturn Limit
Disagreement
Feedback Option Module
Communications Error
(Reception error)
An encoder position data calculation error occurred.
An error occurs in the communications timer between the encoder and the SERVOPACK.
Different multiturn limits have been set in the encoder and the SER-
VOPACK.
Reception from the Feedback Option Module is faulty.
A.CF2
Feedback Option Module
Communications Error
(Timer stop)
Communications between the SERVOPACK and the encoder is not possible.
Timer for communications with the Feedback Option Module is faulty.
A.d00
A.d01
A.d02
A.d10
Position Error Overflow
Position Error Overflow
Alarm at Servo ON
Position Error Overflow
Alarm by Speed Limit at
Servo ON
Position error exceeded the value of excessive position error alarm level (Pn520) when the servomotor power is ON.
This alarm occurs if the servomotor power is turned ON when the position error is greater than the set value of Pn526 while the servomotor power is OFF.
When the position errors remain in the error counter, Pn529 limits the speed if the servomotor power is turned ON. If Pn529 limits the speed in such a state, this alarm occurs when position references are input and the number of position errors exceeds the value set for the excessive position error alarm level (Pn520).
During fully-closed loop control, the position error between motor and load is excessive.
A.E02
A.E40
Motor-load Position Error
Overflow
MECHATROLINK
Internal Synchronization
Error 1
MECHATROLINK
Transmission Cycle
Setting Error
Synchronization error during MECHATROLINK communications with the SERVOPACK.
The setting of the MECHATROLINK transmission cycle is out of the allowable range.
Servomotor
Stopping
Method
Gr.1
Gr.1
Gr.1
Gr.1
Gr.2
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.1
Gr.2
Gr.2
Gr.1
Gr.2
Alarm
Reset
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Available
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Available
Available
Available
Available
Available
Available
9.1 Alarm Displays
(cont’d)
Alarm
Number
Alarm Name Meaning
A.E50
A.E51
A.E60
A.E61
A.E71
A.E72
A.E74
A.E75
A.E81
*2
A.EA2
A.Eb1
A.Eb
*2
A.EC
*2
A.Ed1
A.F10
A.F30
MECHATROLINK
Synchronization Error
MECHATROLINK
Synchronization Failed
MECHATROLINK
Communications Error
(Reception error)
MECHATROLINK
Transmission Cycle Error
(Synchronization interval error)
Safety Option Module
Detection Failure
Feedback Option Module
Detection Failure
Unsupported Safety
Option Module
Unsupported Feedback
Option Module
SERVOPACK: Safety
Module Alarm
DRV Alarm 2
(SERVOPACK WDC error)
Safety Function Signal
Input Timing Error
SERVOPACK: Safety
Module Alarms
SERVOPACK: Safety
Module Alarms
Command Execution
Timeout
Main Circuit Cable Open
Phase
Dynamic Brake Contactor
Error
A synchronization error occurs during MECHATROLINK communications.
A synchronization failure occurs in MECHATROLINK communications.
A communications error occurs continuously during MECHA-
TROLINK communications.
The transmission cycle fluctuates during MECHATROLINK communications.
Detection of the safety option module failed.
Detection of the Feedback Option Module failed.
An unsupported safety option module was connected.
An unsupported feedback option module was connected.
–
A SERVOPACK DRV alarm 0 occurs.
The safety function signal input timing is faulty.
–
–
A timeout error occurred when using a MECHATROLINK command.
With the main circuit power supply ON, voltage was low for more than 1 second in phase R, S, or T.
An error occurred in the operation of the dynamic brake contactor.
FL-1
*3
FL-2
*3
System Alarm Internal program error occurred in the SERVOPACK
CPF00
CPF01
A.
− −
Digital Operator
Transmission Error 1
Digital Operator
Transmission Error 2
Digital operator (JUSP-OP05A-1-E) fails to communicate with the
SERVOPACK (e.g., CPU error).
Not an error Normal operation status
∗2.
These alarms occur in SERVOPACKs with safety modules.
For details, refer to Σ -V Series User’s Manual, Safety Module (No.: SIEP C720829 06).
∗3.
These alarms are not stored in the alarm history and are displayed only in the panel display.
Servomotor
Stopping
Method
Gr.2
Gr.2
Gr.2
Gr.2
Gr.1
Gr.1
Gr.1
Gr.1
–
Gr.2
Gr.1
–
–
Gr.2
Gr.2
Gr.2
−
−
−
−
−
Alarm
Reset
Available
Available
Available
Available
N/A
N/A
N/A
N/A
–
Available
N/A
–
–
Available
Available
Available
N/A
N/A
N/A
N/A
−
9
9-5
9-6
9 Troubleshooting
9.1.2 Troubleshooting of Alarms
9.1.2
Troubleshooting of Alarms
If an error occurs in servo drives, an alarm display such as A.
play.
and CPF will appear on the panel dis-
Refer to the following table to identify the cause of an alarm and the action to be taken.
Contact your Yaskawa representative if the problem cannot be solved by the described corrective action.
Alarm Number:
Alarm Name
(Alarm Description)
Cause Investigative Actions Corrective Actions
A.020:
Parameter Checksum
Error 1
(The parameter data in the SERVOPACK is incorrect.)
A.021:
Parameter Format
Error 1
(The parameter data in the SERVOPACK is incorrect.)
A.022:
System Checksum
Error 1
(The parameter data in the SERVOPACK is incorrect.)
A.030:
Main Circuit Detector
Error
A.040:
Parameter Setting
Error 1
(The parameter setting was out of the setting range.)
The power supply voltage suddenly dropped.
The power supply went OFF while changing a parameter setting.
The number of times that parameters were written exceeded the limit.
Malfunction caused by noise from the AC power supply or grounding line, static electricity noise, etc.
Gas, water drops, or cutting oil entered the SERVOPACK and caused failure of the internal components.
Check to see if the parameters were frequently changed through the host controller.
Turn the power supply ON and OFF several times. If the alarm still occurs, there may be noise interference.
Take countermeasures against noise.
Check the installation conditions.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
Reconsider the method of writing parameters.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
A fault occurred in the SERVO-
PACK.
Check the circumstances when the power supply went OFF.
Turn the power supply ON and OFF several times. If the alarm still occurs, the SERVOPACK may be faulty.
Set Fn005 to initialize the parameter and then set the parameter again.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
The software version of SERVO-
PACK that caused the alarm is older than that of the written parameter.
A fault occurred in the SERVO-
PACK.
The power supply voltage suddenly dropped.
The power supply went OFF while setting an utility function.
A fault occurred in the SERVO-
PACK.
Measure the power supply voltage.
Check Fn012 to see if the set software version agrees with that of the
SERVOPACK. If not, an alarm may occur.
−
Measure the power supply voltage.
Check the circumstances when the power supply went OFF.
Turn the power supply ON and OFF several times. If the alarm still occurs, the SERVOPACK may be faulty.
Set the power supply voltage within the specified range, and set Fn005 to initialize the parameter.
Write the parameter of another
SERVOPACK of the same model with the same software version.
Then turn the power OFF and then
ON again.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
A fault occurred in the SERVO-
PACK or converter.
−
The SERVOPACK or converter may be faulty. Replace the SERVO-
PACK or converter.
The SERVOPACK capacity, converter capacity, and the servomotor capacity do not match each other.
A fault occurred in the SERVO-
PACK.
The parameter setting is out of the setting range.
The electronic gear ratio is out of the setting range.
Check the combination of SERVO-
PACK, converter, and servomotor capacities.
−
Check the setting ranges of the parameters that have been changed.
Check the electronic gear ratio. The ratio must satisfy:
0.001< (Pn20E/Pn210) < 4000.
Select the proper combination of capacities.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
Set the parameter to a value within the setting range.
Set the electronic gear ratio in the range: 0.001< (Pn20E/Pn210)
< 4000.
9.1 Alarm Displays
Alarm Number:
Alarm Name
(Alarm Description)
The setting of the fully-closed module does not match with that of Pn002.3.
Cause
A.041:
Encoder Output Pulse
Setting Error
A.042:
Parameter
Combination Error
The encoder output pulse (Pn212) is out of the setting range and does not satisfy the setting conditions.
The speed of program JOG operation (Fn004) is lower than the setting range after having changed the electronic gear ratio
(Pn20E/Pn210) or the servomotor.
The speed of program JOG operation (Fn004) is lower than the setting range after having changed the setting of the program JOG movement speed
(Pn533).
The moving speed of advanced autotuning is lower than the setting range after having changed the electronic gear ratio (Pn20E/
Pn210) or the servomotor.
A.044:
Semi-closed/Fullyclosed Loop Control
Parameter Setting
Error
A.04A:
Parameter Setting
Error 2
For a 4-byte parameter bank, no registration in two consecutive bytes for two bank members.
The total amount of bank data exceeds 64. (Pn900 × Pn901 >
64)
Investigative Actions
Check the parameter Pn212.
Check if the detection conditions
*1 are satisfied.
Check if the detection conditions
*1 are satisfied.
Check if the detection conditions
*1 are satisfied.
Check the settings of Pn002.3.
–
–
A.050:
Combination Error
(The SERVOPACK and servomotor capacities do not correspond.)
The SERVOPACK and servomotor capacities do not match each other.
An encoder fault occurred.
A fault occurred in the SERVO-
PACK or converter.
Check the capacities to see if they satisfy the following condition:
1
4
≤
Servomotor capacity
SERVOPACK capacity
≤ 4
Replace the servomotor and see if the alarm occurs again.
−
Corrective Actions
Set Pn212 to a correct value.
Decrease the setting of the electronic gear ratio (Pn20E/Pn210).
Increase the setting of the program
JOG movement speed (Pn533).
Decrease the setting of the electronic gear ratio (Pn20E/Pn210).
The setting of fully-closed module must be compatible with the setting of Pn002.3.
Change the number of bytes for bank members to an appropriate value.
Reduce the total amount of bank data to 64 or less.
Select the proper combination of
SERVOPACK and servomotor capacities.
Replace the servomotor (encoder).
The SERVOPACK or converter may be faulty. Replace the SERVO-
PACK or converter.
A.051:
Unsupported Device
Alarm
An unsupported serial converter unit, encoder, or external encoder is connected to the SERVO-
PACK.
Check the product specifications, and select the correct model.
A.0b0:
Cancelled Servo ON
Command Alarm
After executing the utility function to turn ON the power to the motor, the servo ON command
(SV_ON) was sent from the host controller.
−
∗1.
Detection conditions
If one of the following conditions detected, an alarm occurs.
•
•
Pn533 [min
-1
] ×
Encoder resolution
6 × 10
5
Max Motor Speed [min
-1
] ×
≤
Pn20E
Pn210
Encoder resolution
About 3.66
× 10
12
≥
Pn20E
Pn210
(cont’d)
Select the correct combination of units.
Turn the SERVOPACK power supply OFF and then ON again or execute a software reset.
9
9-7
9-8
9 Troubleshooting
9.1.2 Troubleshooting of Alarms
(cont’d)
Alarm Number:
Alarm Name
(Alarm Description)
Cause Investigative Actions Corrective Actions
A.100:
Overcurrent or Heat
Sink Overheated
(An overcurrent flowed through the IGBT or heat sink of SERVO-
PACK overheated.)
Incorrect wiring or contact fault of main circuit cables.
Short-circuit or ground fault of main circuit cables.
Short-circuit or ground fault inside the servomotor.
Short-circuit or ground fault inside the SERVOPACK.
The dynamic brake (DB: Emergency stop executed from the
SERVOPACK) was frequently activated, or the DB overload alarm occurred.
A heavy load was applied while the servomotor was stopped or running at a low speed.
Malfunction caused by noise interference.
Check the wiring. Refer to 3.1
Main Circuit Wiring.
Check for short-circuits across the servomotor terminal phases U, V, and W, or between the grounding and servomotor terminal phases U,
V, or W. Refer to 3.1 Main Circuit
Wiring .
Check for short-circuits across the servomotor terminal phases U, V, and W, or between the grounding and servomotor terminal phases U,
V, or W. Refer to 3.1 Main Circuit
Wiring .
Check for short-circuits across the servomotor connection terminals U,
V, and W on the SERVOPACK, or between the grounding and terminal
U, V, or W. Refer to 3.1 Main Circuit Wiring .
Check the power consumed by DB resistance (Un00B) to see how many times the DB has been used.
Or, check the alarm history display
Fn000 to see if the DB overload alarm A.730 or A.731 was reported.
Check to see if the operating conditions are outside servo drive specifications.
Improve the wiring or installation environment, such as by reducing noise, and check to see if the alarm recurs.
Correct the wiring.
The cable may be short-circuited.
Replace the cable.
The servomotor may be faulty.
Replace the servomotor.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
Change the SERVOPACK model, operating conditions, or the mechanism so that the DB does not need to be used so frequently.
Reduce the load applied to the servomotor or increase the operating speed.
Take countermeasures for noise, such as correct wiring of the FG.
Use an FG wire size equivalent to the main circuit wire size of the
SERVOPACK and converter.
The setting of Pn515.2 (Dynamic
Brake Answer Signal 1 (/
DBANS1) Input Signal Mapping) does not agree with the contacts of the dynamic brake contactor that is connected.
Current flowed to the dynamic brake resistor when power to the servomotor was ON due to welding or other failure of the dynamic brake contacts.
Check the setting of Pn515.2 and the contacts of the dynamic brake contactor.
Check the contactor to see if it is welded.
Set Pn515.2 to agree with the contacts of the dynamic brake contactor.
The dynamic brake contactor may have failed. Replace the dynamic brake contactor.
A fault occurred in the SERVO-
PACK.
−
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK or converter may be faulty. Replace the
SERVOPACK or converter.
9.1 Alarm Displays
(cont’d)
Alarm Number:
Alarm Name
(Alarm Description)
Cause Investigative Actions Corrective Actions
A.300:
Regeneration Error
A.320:
Regenerative
Overload
A.330:
Main Circuit Power
Supply Wiring Error
(Detected when the power to the main circuit is turned ON.)
An external regenerative resistor unit is not connected.
The regenerative resistor unit is incorrectly wired, or is removed or disconnected.
The connection of the I/O signals
(CN901) between the SERVO-
PACK and converter is faulty.
Check the external regenerative resistor unit connection.
Check the regenerative resistor unit connection.
Check the connection of CN901.
Connect the external regenerative resistor unit.
Correctly connect the regenerative resistor unit.
Correctly connect CN901.
A fault occurred in the SERVO-
PACK or converter.
−
While the main circuit power supply is OFF, turn the control power supply OFF and then ON again. If the alarm still occurs, the SERVO-
PACK or converter may be faulty.
Replace the SERVOPACK or converter.
The power supply voltage exceeds the specified limit.
Insufficient regenerative resistance, regenerative resistor capacity.
Or, regenerative power has been continuously flowing back.
Regenerative power continuously flowed back because negative load was continuously applied.
The setting of parameter Pn600 is smaller than the regenerative resistor's capacity.
Check the operating condition or the capacity using the capacity selection Software SigmaJunma-
Size+, etc.
Check the load applied to the servomotor during operation.
Change the regenerative resistance, regenerative resistor capacity.
Reconsider the operating conditions using the capacity selection software SigmaJunmaSize+, etc.
Reconsider the system including servo, machine, and operating conditions.
The regenerative resistance is too high.
Check the regenerative resistor unit connection and the value of the
Pn600.
Set the Pn600 to a correct value.
Check the regenerative resistance.
Change the regenerative resistance to a correct value or use an external regenerative resistor of appropriate capacity.
The connection of the I/O signals
(CN901) between the SERVO-
PACK and converter is faulty.
Check the connection of CN901.
Correctly connect CN901.
A fault occurred in the SERVO-
PACK or converter.
−
The SERVOPACK or converter may be faulty. Replace the SERVO-
PACK or converter.
The regenerative resistor unit was disconnected when the power supply voltage to the SERVO-
PACK and converter was high.
Measure the resistance of the regenerative resistor unit using a measuring instrument.
Replace the regenerative resistor unit.
DC power was supplied.
An regenerative resistor unit is not connected.
The 1 and 2 terminals of the converter are open.
The connection of the I/O signals
(CN901) between the SERVO-
PACK and converter is faulty.
Check the power supply to see if it is a AC power supply.
Check the regenerative resistor unit connection.
Check the 1 and 2 terminals on the converter.
Use an AC power supply.
Connect the regenerative resistor unit.
Correctly connect the 1 and 2 terminals on the converter.
Check the connection of CN901.
Correctly connect CN901.
A fault occurred in the SERVO-
PACK or converter.
−
The SERVOPACK or converter may be faulty. Replace the SERVO-
PACK or converter.
9
9-9
9-10
9 Troubleshooting
9.1.2 Troubleshooting of Alarms
(cont’d)
Alarm Number:
Alarm Name
(Alarm Description)
Cause Investigative Actions Corrective Actions
A.400:
Overvoltage
(Detected in the SER-
VOPACK main circuit power supply section.)
A.410:
Undervoltage
(Detected in the SER-
VOPACK main circuit power supply section.)
The AC power supply voltage exeeded:
• 290 VAC for 200-VAC SER-
VOPACKs.
• 580 VAC for 400-VAC SER-
VOPACKs.
The AC power supply voltage dropped to:
• 120 V or less for 200-VAC
SERVOPACKs.
• 240 V or less for 400-VAC
SERVOPACKs.
The power supply voltage dropped during operation.
Measure the power supply voltage.
Measure the power supply voltage.
Measure the power supply voltage.
Set AC power supply voltage within the specified range.
The power supply is unstable, or was influenced by a lightning surge.
Voltage for AC power supply was too high during acceleration or deceleration.
The regenerative resistance is too high for the actual operating conditions.
The moment of inertia ratio exceeded the allowable value.
The fuse in the converter’s regeneration circuit is blown out.
Measure the power supply voltage.
Check the operating conditions and the regenerative resistance.
Improve the power supply conditions by installing a surge absorber, etc. Then, turn the power supply
OFF and ON again. If the alarm still occurs, the SERVOPACK or converter may be faulty. Replace the
SERVOPACK or converter.
Check the power supply voltage and the speed and torque during operation.
Set AC power supply voltage within the specified range.
Select a regenerative resistance value appropriate for the operating conditions and load.
Increase the deceleration time, or reduce the load.
Confirm that the moment of inertia ratio is within the allowable range.
Check for a Regeneration Error alarm (A.300) and check the
CHARGE indicator on the converter to see if it remains lit for more than a few seconds immediately after the main circuit power supply is turned OFF.
The converter may be faulty.
Replace the converter.
The connection of the I/O signals
(CN901) between the SERVO-
PACK and converter is faulty.
Check the connection of CN901.
Correctly connect CN901.
A fault occurred in the SERVO-
PACK or converter.
−
Turn the control power OFF and then ON again while the main circuit power supply is OFF. If the alarm still occurs, the SERVO-
PACK or converter may be faulty.
Replace the SERVOPACK or converter.
Set the power supply voltage within the specified range.
Increase the power supply capacity.
Occurrence of instantaneous power interruption.
The converter fuse is blown out.
The 1 and 2 terminals of the converter are open.
A fault occurred in the SERVO-
PACK or converter.
Measure the power supply voltage.
−
Check the 1 and 2 terminals on the converter.
−
When the instantaneous power cut hold time (Pn509) is set, decrease the setting.
Replace the converter, connect a reactor, and run the SERVOPACK and converter.
Correctly connect the 1 and 2 terminals on the converter.
The SERVOPACK or converter may be faulty. Replace the SERVO-
PACK or converter.
9.1 Alarm Displays
(cont’d)
Alarm Number:
Alarm Name
(Alarm Description)
Cause Investigative Actions Corrective Actions
The Converter fan stopped (The
FAN STOP indicator on the converter is lit.).
Check for foreign matter or debris inside the converter.
Remove foreign matter or debris from the converter. If the alarm still occurs, the SERVOPACK or converter may be faulty. Replace the
SERVOPACK or converter.
A.42A:
Converter error
A.450:
Main-Circuit
Capacitor Overvoltage
A.510:
Overspeed
(The servomotor speed exceeds the maximum.)
A.511:
Overspeed of Encoder
Output Pulse Rate
An error was detected in the magnetic contactor inside the converter. (The CHRG-ERR indicator on the converter lights when the power supply is turned
ON.)
Overheating was detected in the heat sink in the converter (The
OVERHEAT indicator on the converter is lit.).
The DC output voltage from the converter is not correct. (The
CHRG-ERR indicator on the converter is lit.)
The timing of inputting the control power supply to the SERVO-
PACK and converter is incorrect.
Measure the power supply voltage and the output voltage.
Measure the power supply voltage waveform when the power supply is turned ON and OFF.
Check the timing of inputting the control power supply to the SER-
VOPACK and converter.
The wiring between the SERVO-
PACK and converter is incorrect or the connection is faulty.
Check the wiring.
The connection of the I/O signals
(CN901) between the SERVO-
PACK and converter is faulty.
Check the connection of CN901.
A fault occurred in the converter.
−
The fuse in the SERVOPACK is blown out.
Check to see if this alarm occurs when the main circuit power supply is turned ON.
A fault occurred in the SERVO-
PACK or converter.
The order of phases U, V, and W in the servomotor wiring is incorrect.
A reference value exceeding the overspeed detection level was input.
−
Check the motor wiring.
Check the input value.
If the output voltage is not consistent with the power supply voltage, the converter may be faulty.
Replace the converter.
If the voltage waveform is not stable, take suitable measures to make it stable.
Input the control power supply simultaneously to the SERVO-
PACK and converter.
Correctly connect the SERVO-
PACK and converter to each other.
Correctly connect CN901.
Replace the converter.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
Replace the SERVOPACK or converter.
Confirm that the servomotor is correctly wired.
Reduce the reference value or adjust the gain.
The motor speed exceeded the maximum.
A fault occurred in the SERVO-
PACK or converter.
The encoder output pulse frequency exceeded the limit.
The encoder output pulse output frequency exceeded the limit because the motor speed was too high.
Check to see if you can hear the magnetic contactor operate when the power supply is turned ON.
Check the ambient temperature, check for an overload, and check the installation method.
Check the motor speed waveform.
−
Check the encoder output pulse setting.
Check the encoder output pulse output setting and motor speed.
If the power supply voltage is correct but no sound is heard when the power supply is turned ON, the converter may be faulty. Replace the converter.
Review the ambient temperature, load conditions, and installation conditions.
Reduce the speed reference input gain, adjust the servo gain, or reconsider the operating conditions.
The SERVOPACK or converter may be faulty. Replace the SERVO-
PACK or converter.
Decrease the setting of the encoder output pulse (Pn212).
Decrease the motor speed.
9
9-11
9-12
9 Troubleshooting
9.1.2 Troubleshooting of Alarms
(cont’d)
Alarm Number:
Alarm Name
(Alarm Description)
A.730:
A.731:
Dynamic Brake
Overload
(An excessive power consumption of dynamic brake was detected.) ity.
Cause
A.520:
Vibration Alarm
A.521:
Autotuning Alarm
(Vibration was detected while executing the oneparameter tuning, Easy-
FFT, or tuning-less function.)
Abnormal vibration was detected at the motor speed.
Check for abnormal noise from the servomotor, and check the speed and torque waveforms during operation.
The moment of inertia ratio
(Pn103) value is greater than the actual value or is greatly changed.
Check the moment of inertia ratio.
Reduce the motor speed or reduce the speed loop gain (Pn100).
Set the moment of inertia ratio
(Pn103) to an appropriate value.
The servomotor vibrated considerably while performing tuningless function.
The servomotor vibrated considerably during one-parameter tuning or EasyFFT.
Incorrect wiring or contact fault of servomotor and encoder.
Operation beyond the overload protection characteristics.
Check the motor speed waveform.
Check the motor speed waveform.
Check the wiring.
Check the servomotor overload characteristics and executed run command.
Reduce the load so that the moment of inertia ratio falls within the allowable value, or raise the load level using the tuning-less levels setting (Fn200) or reduce the rigidity level.
Check the operation procedure of corresponding function and take a corrective action.
Confirm that the servomotor and encoder are correctly wired.
Reconsider the load conditions and operating conditions. Or, increase the motor capacity.
A.710:
A.720:
Overload
A.710: High Load
A.720: Low Load
Excessive load was applied during operation because the servomotor was not driven due to mechanical problems.
Check the executed operation reference and motor speed.
Remove the mechanical problems.
A fault occurred in the SERVO-
PACK or converter.
The servomotor rotates because of external force.
The rotating energy at a DB stop exceeds the DB resistance capac-
The setting of Pn001.0 (Servomotor Power OFF or Alarm Gr.1
Stop Mode) is not correct.
The setting of Pn601 does not agree with the dynamic brake resistance that is connected.
The connection of the dynamic brake unit is faulty.
A fault occurred in the SERVO-
PACK.
−
Check the operation status.
Check the power consumed by DB resistance (Un00B) to see how many times the DB has been used.
Check the setting of Pn001.0.
Check the setting of Pn601.
Check the wiring between the dynamic brake unit and DU, DV,
DW, and CN115 is correct and securely connected.
−
Investigative Actions Corrective Actions
The SERVOPACK or converter may be faulty. Replace the SERVO-
PACK or converter.
Take measures to ensure the servomotor will not rotate because of external force.
Reconsider the following:
• Reduce the motor reference speed.
• Reduce the moment of inertia ratio.
• Reduce the number of times of the DB stop operation.
To not use the dynamic brake, set
Pn001.0 to 2. (The dynamic brake will not be used and the motor will coast to a stop.)
Set Pn601 correctly.
Correctly wire and securely connect the dynamic brake unit with DU,
DV, DW, and CN115.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
9.1 Alarm Displays
(cont’d)
Alarm Number:
Alarm Name
(Alarm Description)
Cause
A.740:
Overload of Surge
Current Limit Resistor
(The main circuit power is turned ON/OFF too frequently.)
The inrush current limit resistor operation frequency at the main circuit power supply ON/OFF operation exceeds the allowable range.
A fault occurred in the SERVO-
PACK or converter.
−
Investigative Actions Corrective Actions
Reduce the frequency of turning the main circuit power supply ON/OFF.
The surrounding air temperature is too high.
A.7A0:
Heat Sink Overheated
(Detected when the
SERVOPACK’s heat sink temperature exceeds 100 ° C.)
The overload alarm has been reset by turning OFF the power too many times.
Excessive load or operation beyond the regenerative energy processing capacity.
Incorrect installation orientation of the SERVOPACK or/and insufficient space around the
SERVOPACK.
A fault occurred in the SERVO-
PACK.
−
Check the surrounding air temperature using a thermostat.
Check the alarm history display
(Fn000) to see if the overload alarm was reported.
Check the accumulated load ratio
(Un009) to see the load during operation, and the regenerative load ratio (Un00A) to see the regenerative energy processing capacity.
Check the installation conditions of the SERVOPACK.
The SERVOPACK or converter may be faulty. Replace the SERVO-
PACK or converter.
Decrease the surrounding air temperature by improving the installation conditions of the SERVOPACK.
Change the method for resetting the alarm.
Reconsider the load and operating conditions.
Install the SERVOPACK correctly as specified.
A.7AB:
Built-in Fan in
SERVOPACK
Stopped
The fan inside the SERVOPACK stopped.
−
Check for foreign matter or debris inside the SERVOPACK.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
Remove foreign matter or debris from the SERVOPACK. If the alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
A.810:
Encoder Backup Error
(Only when an absolute encoder is connected.)
(Detected on the encoder side.)
Alarm occurred when the power to the absolute encoder was initially turned ON.
The encoder cable disconnected, and connected again.
The power from both the control power supply (+5 V) from the
SERVOPACK and the battery power supply is not being supplied.
An absolute encoder fault occurred.
Check to see if the power was turned ON initially.
Check to see if the power was turned ON initially.
Check the encoder connector battery or the connector contact status.
−
Set up the encoder (Fn008).
Confirm the connection and set up the encoder (Fn008).
Replace the battery or take similar measures to supply power to the encoder, and set up the encoder
(Fn008).
A.820:
Encoder Checksum
Error
(Detected on the encoder side.)
A fault occurred in the SERVO-
PACK.
An encoder fault occurred.
−
−
If the alarm cannot be reset by setting up the encoder again, replace the servomotor.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
• Absolute encoder
Set up the encoder again using
Fn008. If the alarm still occurs, the servomotor may be faulty.
Replace the servomotor.
• Absolute encoder that shows values for a single rotation or incremental encoder
The servomotor may be faulty.
Replace the servomotor.
A fault occurred in the SERVO-
PACK.
−
The SERVOPACK may be faulty.
Replace the SERVOPACK.
9
9-13
9-14
9 Troubleshooting
9.1.2 Troubleshooting of Alarms
A.8A0:
External Encoder
Error
Setting the zero point position of external absolute encoder failed because the servomotor rotated.
The servomotor must be stopped while setting the zero point position.
(cont’d)
Alarm Number:
Alarm Name
(Alarm Description)
Cause
A.830:
Absolute Encoder
Battery Error
(The absolute encoder battery voltage is lower than the specified value.)
The battery connection is incorrect.
The battery voltage is lower than the specified value 2.7 V.
A fault occurred in the SERVO-
PACK.
Investigative Actions
Check the battery connection.
Measure the battery voltage.
Corrective Actions
Reconnect the battery.
Replace the battery.
A.840:
Encoder Data Error
(Detected on the encoder side.)
A.850:
Encoder Overspeed
(Detected when the control power supply was turned ON.)
(Detected on the encoder side.)
An encoder malfunctioned.
Malfunction of encoder because of noise interference, etc.
The servomotor speed is higher than 200 min
-1
when the control power supply was turned ON.
An encoder fault occurred.
A fault occurred in the SERVO-
PACK.
−
−
−
Check the motor rotating speed
(Un000) to confirm the servomotor speed when the power is turned ON.
−
−
The SERVOPACK may be faulty.
Replace the SERVOPACK.
Turn the power supply OFF and then ON again. If the alarm still occurs, the servomotor may be faulty. Replace the servomotor.
Correct the wiring around the encoder by separating the encoder cable from the servomotor main circuit cable or by checking the grounding and other wiring.
Reduce the servomotor speed to a value less than 200 min
-1
, and turn
ON the control power supply.
Turn the power supply OFF and then ON again. If the alarm still occurs, the servomotor may be faulty. Replace the servomotor.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
The ambient operating temperature around the servomotor is too high.
The motor load is greater than the rated load.
A.860:
Encoder Overheated
(Only when an absolute encoder is connected.)
(Detected on the encoder side.)
An encoder fault occurred.
A fault occurred in the SERVO-
PACK.
Measure the ambient operating temperature around the servomotor.
The ambient operating temperature must be 40 ° C or less.
Check the accumulated load ratio
(Un009) to see the load.
−
−
The motor load must be within the specified range.
Turn the power supply OFF and then ON again. If the alarm still occurs, the servomotor may be faulty. Replace the servomotor.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
Before setting the zero point position, use the fully-closed feedback pulse counter (Un00E) to confirm that the servomotor is not rotating.
A.8A1:
External Encoder
Error of Module
An external encoder fault occurred.
An external encoder fault occurred.
A serial converter unit fault occurred.
−
−
−
Replace the external encoder.
Replace the external encoder.
Replace the serial converter unit.
A.8A2:
External Encoder
Error of Sensor
(Incremental)
A.8A3:
External Encoder
Error of Position
(Absolute)
An external encoder fault occurred.
An external absolute encoder fault occurred.
−
−
Replace the external encoder.
The external absolute encoder may be faulty. Refer to the encoder manufacturer’s instruction manual for corrective actions.
9.1 Alarm Displays
(cont’d)
Alarm Number:
Alarm Name
(Alarm Description)
A.8A5:
External Encoder
Overspeed
A.8A6:
External Encoder
Overheated
A.b31:
Current Detection
Error 1
Cause
The overspeed from the external encoder occurred.
The overheat from the external encoder occurred.
Check the maximum speed of the external encoder.
−
Investigative Actions Corrective Actions
Keep the external encoder below its maximum speed.
Replace the external encoder.
A.b32:
Current Detection
Error 2
A.b33:
Current Detection
Error 3
The detection circuit for the current is faulty.
The servomotor main circuit cable is disconnected.
A.b6A:
MECHATROLINK
Communications ASIC
Error 1
SERVOPACK MECHA-
TROLINK communication section fault.
A.b6b:
MECHATROLINK
Communications ASIC
Error 2
A.bF0:
System Alarm 0
A.bF1:
System Alarm 1
A.bF2:
System Alarm 2
A.bF3
:
System Alarm 3
A.bF4:
System Alarm 4
The current detection circuit for phase U is faulty.
The current detection circuit for phase V is faulty.
MECHATROLINK data reception error occurred due to noise interference.
SERVOPACK MECHA-
TROLINK communication section fault.
A fault occurred in the SERVO-
PACK.
A fault occurred in the SERVO-
PACK.
A fault occurred in the SERVO-
PACK.
A fault occurred in the SERVO-
PACK.
A fault occurred in the SERVO-
PACK.
−
−
−
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
Check for disconnection of the servomotor main circuit cable.
Correct the servomotor wiring.
−
−
−
−
−
−
−
−
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
Take measures against noise. Check the MECHATROLINK communications cable and FG wiring and take measures such as adding ferrite core on the MECHATROLINK communications cable.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
9
9-15
9-16
9 Troubleshooting
9.1.2 Troubleshooting of Alarms
(cont’d)
Alarm Number:
Alarm Name
(Alarm Description)
Cause Investigative Actions Corrective Actions
The order of phases U, V, and W in the servomotor wiring is incorrect.
Check the motor wiring.
Confirm that the servomotor is correctly wired.
A.C10:
Servo Overrun
Detected
(Detected when the servomotor power is
ON.)
A.C80:
Absolute Encoder
Clear Error and
Multi-turn Limit Setting Error
An encoder fault occurred.
A fault occurred in the SERVO-
PACK or converter.
An encoder fault occurred.
A fault occurred in the SERVO-
PACK.
−
−
−
−
If the alarm still occurs after turning the power OFF and then ON again, even though the servomotor is correctly wired, the servomotor may be faulty. Replace the servomotor.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK or converter may be faulty. Replace the
SERVOPACK or converter.
Turn the power supply OFF and then ON again. If the alarm still occurs, the servomotor may be faulty. Replace the servomotor.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
A.C90:
Encoder
Communications Error
Contact fault of connector or incorrect wiring for encoder cable.
Cable disconnection for encoder cable or short-circuit.
Or, incorrect cable impedance.
Corrosion caused by improper temperature, humidity, or gas, short-circuit caused by intrusion of water drops or cutting oil, or connector contact fault caused by vibration.
Check the connector contact status for encoder cable.
Check the encoder cable.
Check the operating environment.
A.C91:
Encoder
Communications
Position Data Error
Re-insert the connector and confirm that the encoder is correctly wired.
Use the cable with the specified rating.
Improve the operating environmental conditions, and replace the cable.
If the alarm still occurs, replace the
SERVOPACK.
Malfunction caused by noise interference.
A fault occurred in the SERVO-
PACK.
−
−
Correct the wiring around the encoder by separating the encoder cable from the servomotor main circuit cable or by checking the grounding and other wiring.
Connect the servomotor to another
SERVOPACK, and turn ON the control power. If no alarm occurs, the SERVOPACK may be faulty.
Replace the SERVOPACK.
Noise interference occurred on the I/O signal line because the encoder cable is bent and the sheath is damaged.
The encoder cable is bundled with a high-current line or near a high-current line.
The FG potential varies because of influence from machines on the servomotor side, such as the welder.
Check the encoder cable and connector.
Check the cable layout for encoder cable.
Check the cable layout for encoder cable.
Confirm that there is no problem with the cable layout.
Confirm that there is no surge voltage on the cable.
Properly ground the machines to separate from the encoder FG.
9.1 Alarm Displays
Alarm Number:
Alarm Name
(Alarm Description)
A.C92:
Encoder
Communications
Timer Error
A.CA0:
Encoder Parameter
Error
A.Cb0:
Encoder Echoback
Error
A.CC0:
Multiturn Limit
Disagreement
(cont’d)
Corrective Actions Cause Investigative Actions
Noise interference occurred on the I/O signal line from the encoder.
Excessive vibration and shocks were applied to the encoder.
An encoder fault occurred.
A fault occurred in the SERVO-
PACK.
An encoder fault occurred.
A fault occurred in the SERVO-
PACK.
−
Check the operating environment.
−
−
−
−
Take countermeasures against noise for the encoder wiring.
Reduce the machine vibration or correctly install the servomotor.
Turn the power supply OFF and then ON again. If the alarm still occurs, the servomotor may be faulty. Replace the servomotor.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
Turn the power supply OFF and then ON again. If the alarm still occurs, the servomotor may be faulty. Replace the servomotor.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
The wiring and contact for encoder cable are incorrect.
Noise interference occurred due to incorrect cable specifications of encoder cable.
Check the wiring.
−
Correct the wiring.
Use tinned annealed copper shielded twisted-pair or screened unshielded twisted-pair cable with a core of at least 0.12 mm
2
.
The wiring distance must be 50 m max.
Noise interference occurred because the wiring distance for the encoder cable is too long.
The FG potential varies because of influence from machines on the servomotor side, such as the welder.
Excessive vibration and shocks were applied to the encoder.
−
Check the cable layout for encoder cable.
Properly ground the machines to separate from encoder FG.
An encoder fault occurred.
A fault occurred in the SERVO-
PACK.
A fault occurred in the SERVO-
PACK.
Check the operating environment.
−
−
−
Reduce the machine vibration or correctly install the servomotor.
Turn the power supply OFF and then ON again. If the alarm still occurs, the servomotor may be faulty. Replace the servomotor.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
The multiturn limit value of the encoder is different from that of the SERVOPACK. Or, the multiturn limit value of the SERVO-
PACK has been changed.
Check the value of the Pn205 of the
SERVOPACK.
Execute Fn013 at the occurrence of alarm.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
9
9-17
9-18
9 Troubleshooting
9.1.2 Troubleshooting of Alarms
(cont’d)
Alarm Number:
Alarm Name
(Alarm Description)
Cause Investigative Actions Corrective Actions
A.CF1:
Feedback Option
Module
Communications Error
(Reception error)
A.CF2:
Feedback Option
Module
Communications Error
(Timer stop)
A.d00:
Position Error
Overflow
(Position error exceeded the value set in the excessive position error alarm level (Pn520).)
A.d01:
Position Error
Overflow Alarm at
Servo ON
A.d02:
Position Error
Overflow Alarm by
Speed Limit at Servo
ON
Wiring of cable between serial converter unit and SERVOPACK is incorrect or contact is faulty.
The specified cable is not used between serial converter unit and
SERVOPACK.
Cable between serial converter unit and SERVOPACK is too long.
Sheath of cable between serial converter unit and SERVOPACK is broken.
Check the external encoder wiring.
Correct the cable wiring.
Confirm the external encoder wiring specifications.
Measure the length of this cable.
Check the cable for damage.
Use the specified cable.
Use 20-m cable max.
Replace the cable.
Noise interferes with the cable between serial converter unit and
SERVOPACK.
−
Correct the wiring around serial converter unit, e.g., separating I/O signal line from main circuit cable or grounding.
A serial converter unit fault occurred.
A fault occurred in the SERVO-
PACK.
−
−
Replace the serial converter unit.
Replace the SERVOPACK.
The servomotor U, V, and W wirings is faulty.
The position reference speed is too high.
The acceleration of the position reference is too high.
Check the servomotor main circuit cable connection.
Reduce the reference speed, and operate the SERVOPACK.
Reduce the reference acceleration, and operate the SERVOPACK.
Confirm that there is no contact fault in the motor wiring or encoder wiring.
Reduce the position reference speed or acceleration of position reference. Or, reconsider the electronic gear ratio.
Reduce the reference acceleration of the position reference using a
MECHATROLINK command, or smooth the acceleration of the position reference by selecting the position reference filter (ACCFIL) using a MECHATROLINK command.
Setting of the excessive position error alarm level (Pn520) is low against the operating condition.
Check the alarm level (Pn520) to see if it is set to an appropriate value.
Set the Pn520 to proper value.
A fault occurred in the SERVO-
PACK.
−
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
This alarm occurs if the servomotor power is turned ON when the position error is greater than the set value of Pn526 while the servomotor power is OFF.
When the position errors remain in the error counter, Pn529 limits the speed if the servomotor power is ON. If Pn529 limits the speed in such a state, this alarm occurs when position references are input and the number of position errors exceeds the value set for the excessive position error alarm level (Pn520).
Check the position error amount
(Un008) while the servomotor power is OFF.
−
Correct the excessive position error alarm level at servo ON (Pn526).
Correct the excessive position error alarm level (Pn520).
Or, adjust the speed limit level at servo ON (Pn529).
9.1 Alarm Displays
(cont’d)
Alarm Number:
Alarm Name
(Alarm Description)
Cause Investigative Actions Corrective Actions
A.d10:
Motor-load Position
Error Overflow
Motor rotation direction and external encoder installation direction are opposite.
Check the servomotor rotation direction and the external encoder installation direction.
Install the external encoder in the opposite direction, or change the setting of the external encoder usage method (Pn002.3) to reverse the direction.
A.E02:
MECHATROLINK
Internal
Synchronization
Error 1
Mounting of the load (e.g., stage) and external encoder joint installation are incorrect.
MECHATROLINK transmission cycle fluctuated.
A fault occurred in the SERVO-
PACK.
Check the external encoder mechanical connection.
−
−
Check the mechanical joints.
Remove the cause of transmission cycle fluctuation at host controller.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
A.E40:
MECHATROLINK
Transmission Cycle
Setting Error
Setting of MECHATROLINK transmission cycle is out of specifications range.
WDT data of host controller was not updated correctly.
A.E50:
MECHATROLINK
Synchronization Error
A fault occurred in the SERVO-
PACK.
Check the MECHATROLINK transmission cycle setting.
Check the WDT data updating for the host controller.
−
Set the transmission cycle to the proper value.
Update the WDT data at the host controller correctly.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
A.E51:
MECHATROLINK
Synchronization
Failed
A.E60:
MECHATROLINK
Communications error
(Reception error)
A.E61:
MECHATROLINK
Transmission Cycle
Error
(Synchronization interval error)
WDT data of host controller was not updated correctly at the synchronization communications start, and synchronization communications could not start.
A fault occurred in the SERVO-
PACK.
MECHATROLINK wiring is incorrect.
MECHATROLINK data reception error occurred due to noise interference.
A fault occurred in the SERVO-
PACK.
MECHATROLINK transmission cycle fluctuated.
A fault occurred in the SERVO-
PACK.
Check the WDT data updating for the host controller.
−
Check the MECHATROLINK wirings.
−
−
Check the MECHATROLINK transmission cycle setting.
−
Update the WDT data at the host controller correctly.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
Correct the MECHATROLINK wiring.
Connect the terminator correctly.
Take measures against noise. Check the MECHATROLINK communications cable and FG wiring and take measures such as adding ferrite core on the MECHATROLINK communications cable.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
Remove the cause of transmission cycle fluctuation at host controller.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
9
9-19
9-20
9 Troubleshooting
9.1.2 Troubleshooting of Alarms
(cont’d)
Alarm Number:
Alarm Name
(Alarm Description)
Cause Investigative Actions Corrective Actions
A.E71:
Safety Option Module
Detection Failure
The connection between the
SERVOPACK and the safety option module is faulty.
The safety option module was disconnected.
Check the connection between the
SERVOPACK and the safety option module.
Correctly connect the safety option module.
–
Execute Fn014 (Resetting configuration error of option module) with using the digital operator or SigmaWin+ and turn the power supply
OFF and then ON again.
A safety option module fault occurred.
A fault occurred in the SERVO-
PACK.
The connection between the
SERVOPACK and the Feedback
Option Module is Faulty.
–
–
Check the connection between the
SERVOPACK and the Feedback
Option Module.
Replace the safety option module.
Replace the SERVOPACK.
Correctly connect the Feedback
Option Module.
A.E72:
Feedback Option
Module Detection
Failure
The Feedback Option Module was disconnected.
−
A Feedback Option Module fault occurred.
A fault occurred in the SERVO-
PACK.
A safety option module fault occurred.
−
−
−
Execute resetting configuration error in option modules (Fn014) and turn the power supply OFF and then
ON again.
Replace the Feedback Option Module.
Replace the SERVOPACK.
A.E74:
Unsupported Safety
Option Module
A.E75:
Unsupported
Feedback Option
Module
A.EA2:
DRV Alarm 2
(SERVOPACK WDT error)
A.Eb1:
Safety Function Signal
Input Timing Error
A.Ed1:
Command Execution
Timeout
Replace the safety option module.
A unsupported safety option module was connected.
A feedback option module fault occurred.
Refer to the catalog of the connected safety option module.
−
Connect a compatible safety option module.
Replace the feedback option module.
A unsupported feedback option module was connected.
MECHATROLINK transmission cycle fluctuated.
A fault occurred in the SERVO-
PACK.
The lag between activations of the input signals /HWBB1 and
/HWBB2 for the HWBB function is ten second or more.
A timeout error occurred when using an MECHATROLINK command.
Refer to the catalog of the connected feedback option module or the manual of the SERVOPACK.
Check the MECHATROLINK transmission cycle setting.
−
Measure the time lag between the /
HWBB1 and
/HWBB2 signals.
Check the motor status when the command is executed.
Connect a compatible feedback option module.
Remove the cause of transmission cycle fluctuation at host controller.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
The output signal circuits or devices for /HWBB1 and
/HWBB2 or the SERVOPACK input signal circuits may be faulty.
Alternatively, the input signal cables may be disconnected. Check if any of these items are faulty or have been disconnected.
Execute the SV_ON or SENS_ON command only when the motor is not running.
For fully-closed loop control, check the status of the external encoder after an output is made to execute the command.
Execute the SENS_ON command only when an external encoder is connected.
9.1 Alarm Displays
(cont’d)
Alarm Number:
Alarm Name
(Alarm Description)
Cause Investigative Actions Corrective Actions
A.F10:
Main Circuit Cable
Open Phase
(With the main circuit power supply ON, voltage was low for more than 1 second in an R, S, or T phase.)
(Detected when the main power supply was turned
ON.)
A.F30:
Dynamic Brake
Contactor Error
The three-phase power supply wiring is incorrect.
The three-phase power supply is unbalanced.
The connection of the I/O signals
(CN901) between the SERVO-
PACK and converter is faulty.
A fault occurred in the SERVO-
PACK or converter.
The contactor is faulty in the dynamic brake circuit.
Incorrect wiring of the dynamic brake answer signal.
A fault occurred in the SERVO-
PACK.
Check the power supply wiring.
Measure the voltage at each phase of the three-phase power supply.
Check the connection of CN901.
−
Check the contacts to see if they are welded or not.
Check the wiring of the dynamic brake answer signal.
−
Confirm that the power supply is correctly wired.
Balance the power supply by changing phases.
Correctly connect CN901.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK or converter may be faulty. Replace the
SERVOPACK or converter.
The contactor may be faulty.
Replace the contactor.
Correctly wire the dynamic brake answer signal.
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
FL-1
*2
:
System Alarm
FL-2
*2
:
System Alarm
A fault occurred in the SERVO-
PACK.
−
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
CPF00:
Digital Operator
Transmission Error 1
The contact between the digital operator and the SERVOPACK is faulty.
Check the connector contact.
Insert securely the connector or replace the cable.
Malfunction caused by noise interference.
−
A digital operator fault occurred.
−
Keep the digital operator or the cable away from noise sources.
Disconnect the digital operator and then re-connect it. If the alarm still occurs, the digital operator may be faulty. Replace the digital operator.
CPF01:
Digital Operator
Transmission Error 2
A fault occurred in the SERVO-
PACK.
−
Turn the power supply OFF and then ON again. If the alarm still occurs, the SERVOPACK may be faulty. Replace the SERVOPACK.
∗2.
These alarms are not stored in the alarm history and are displayed only in the panel display.
9
9-21
9 Troubleshooting
9.2.1 List of Warnings
9.2
Warning Displays
The following sections describe troubleshooting in response to warning displays.
The warning name and warning meaning output are listed in order of the warning numbers in 9.2.1 List of
Warnings .
The causes of warnings and troubleshooting methods are provided in 9.2.2 Troubleshooting of Warnings .
9.2.1
List of Warnings
This section provides list of warnings.
9-22
Warning
Number
A.900
*1
A.901
A.910
A.911
A.920
A.921
A.930
A.94A
A.94B
A.94C
A.94D
A.94E
A.95A
A.95B
A.95D
A.95E
A.95F
A.960
A.971
A.9A0
*1
*1
*1
*1
*1
*1
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*3
*1
Warning Name Meaning
Position Error Overflow
Position Error Overflow Alarm at
Servo ON
Overload
Vibration
Regenerative Overload
Dynamic Brake Overload
Position error exceeded the parameter setting
(Pn520 × Pn51E/100).
When the servomotor power is ON, the position error exceeded the parameter setting
(Pn526 × Pn528/100).
This warning occurs before the overload alarms (A.710 or A.720) occur. If the warning is ignored and operation continues, an overload alarm may occur.
Abnormal vibration at the motor speed was detected. The detection level is the same as
A.520. Set whether to output an alarm or warning by the vibration detection switch
(Pn310).
This warning occurs before the regenerative overload alarm (A.320) occurs. If the warning is ignored and operation continues, a regenerative overload alarm may occur.
This warning occurs before dynamic brake overload alarm (A.731) occurs. If the warning is ignored and operation continues, a dynamic brake overload alarm may occur.
Absolute Encoder Battery Error This warning occurs when the voltage of absolute encoder’s battery is lowered.
Data Setting Warning 1
(Parameter Number Error)
Data Setting Warning 2
(Out of Range)
Data Setting Warning 3
(Calculation Error)
Data Setting Warning 4
(Parameter Size)
Data Setting Warning 5
(Latch Mode Error)
Command Warning 1
(Unsatisfying Command)
Command Warning 2
(Non-supported
Command)
Command Warning 4
(Command Interference)
Command Warning 5
(Subcommand Disable)
Command Warning 6
(Undefined Command)
MECHATROLINK
Communications Warning
Incorrect command parameter number was set.
Command input data is out of range.
Calculation error was detected.
Data size does not match.
Latch mode error is detected.
Command was sent although the conditions for sending a command were not satisfied.
Unsupported command was sent.
Command, especially latch command, interferes.
Subcommand and main command interfere.
Undefined command was sent.
Communications error occurred during MECHATROLINK communications.
Undervoltage
This warning occurs before undervoltage alarm (A.410) occurs. If the warning is ignored and operation continues, an undervoltage alarm may occur.
Overtravel Overtravel is detected while the servomotor power is ON.
∗1.
Use Pn008.2 to activate or not the warning detection.
∗2.
Use Pn800.1 to activate or not the warning detection.
∗3.
Use Pn008.1 to activate or not the warning detection.
9.2 Warning Displays
9.2.2
Troubleshooting of Warnings
Refer to the following table to identity the cause of a warning and the action to be taken. Contact your
Yaskawa representative if the problem cannot be solved by the described corrective action.
Warning Number: Warning
Name (Warning
Description)
Cause Investigative Actions Corrective Actions
A.900:
Position Error
Overflow
The servomotor U, V, and W wirings is faulty.
Check the servomotor main circuit cable connection.
Confirm that there is no contact fault in the motor wiring or encoder wiring.
The SERVOPACK gain is too low.
Check the SERVOPACK gain.
A fault occurred in the
SERVOPACK.
−
Increase the servo gain by using the function such as advanced autotuning.
The acceleration of the position reference is too high.
Reduce the reference acceleration, and operate the SERVOPACK.
Reduce the reference acceleration of the position reference using a
MECHATROLINK command, or smooth the acceleration of the position reference by selecting the position reference filter (ACCFIL) using a
MECHATROLINK command.
Setting of the excessive position error alarm level (Pn520) is low against the operating condition.
Check the alarm level (Pn520) to see if it is set to an appropriate value.
Set the Pn520 to proper value.
Turn the power supply OFF and then
ON again. If the alarm still occurs, the
SERVOPACK may be faulty. Replace the SERVOPACK.
A.901:
Position Error
Overflow Alarm at Servo ON
When the servomotor power is ON, the position error exceeded the parameter setting
(Pn526 × Pn528/100).
−
Set an appropriate value for the excessive position error warning level at servo ON (Pn528).
A.910:
Overload
(Warning before alarm A.710 or
A.720 occurs)
A.911:
Vibration
Incorrect wiring or contact fault of servomotor and encoder.
Check the wiring.
Confirm that the servomotor and encoder are correctly wired.
Operation beyond the overload protection characteristics.
Excessive load was applied during operation because the servomotor was not driven due to mechanical problems.
Check the motor overload characteristics and executed run command.
Check the executed operation reference and motor speed.
Reconsider the load conditions and operating conditions. Or, increase the motor capacity.
Remove the mechanical problems.
A fault occurred in the
SERVOPACK.
−
Abnormal vibration was detected at the motor speed.
Check for abnormal noise from the servomotor, and check the speed and torque waveforms during operation.
The moment of inertia ratio (Pn103) value is greater than the actual value or is greatly changed.
Check the moment of inertia ratio.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
Reduce the motor speed or reduce the servo gain by using the function such as one-parameter tuning.
Set the moment of inertia ratio
(Pn103) to an appropriate value.
9
9-23
9-24
9 Troubleshooting
9.2.2 Troubleshooting of Warnings
(cont’d)
Warning Number: Warning
Name (Warning
Description)
Cause Investigative Actions
A.920:
Regenerative
Overload
(Warning before the alarm A.320 occurs)
The power supply voltage exceeds the specified limit.
Insufficient regenerative resistance, regenerative resistor capacity,
SERVOPACK capacity, or converter capacity.
Or, regenerative power has been continuously flowing back.
Regenerative power continuously flowed back because negative load was continuously applied.
The servomotor rotates because of external force.
Measure the power supply voltage.
Check the operating condition or the capacity using the capacity selection
Software SigmaJunmaSize+, etc.
Check the load to the servomotor during operation.
Check the operation status.
A.921:
Dynamic Brake
Overload
(Warning before the alarm A.731 occurs)
The rotating energy at a
DB stop exceeds the DB resistance capacity.
Check the power consumed by DB resistance (Un00B) to see how many times the DB has been used.
A.930:
Absolute
Encoder Battery
Error
(The absolute encoder battery voltage is lower than the specified value.)
∗ Only when an absolute encoder is connected.
A.94A
Data Setting
Warning 1
(Parameter Number Error)
A.94B
Data Setting
Warning 2
(Out of Range)
A fault occurred in the
SERVOPACK or converter.
The battery connection is incorrect.
The battery voltage is lower than the specified value 2.7 V.
A fault occurred in the
SERVOPACK.
Disabled parameter number was used.
Attempted to send values outside the range to the command data.
−
Check the battery connection.
Measure the battery voltage.
−
Refer to 9.3 Monitoring Communication Data on Occurrence of an Alarm or Warning to determine which command was the cause of the warning.
Refer to 9.3 Monitoring Communication Data on Occurrence of an Alarm or Warning to determine which command was the cause of the warning.
A.94C
Data Setting
Warning 3
(Calculation Error)
Calculation result of set value is incorrect.
Refer to 9.3 Monitoring Communication Data on Occurrence of an Alarm or Warning to determine which command was the cause of the warning.
Corrective Actions
Set the power supply voltage within the specified range.
Change the regenerative resistance, regenerative resistor capacity, SER-
VOPACK capacity, or converter capacity. Reconsider the operating conditions using the capacity selection software SigmaJunmaSize+, etc.
Reconsider the system including servo drives, machine, and operating conditions.
Take measures to ensure the servomotor will not rotate because of external force.
Reconsider the following:
• Reduce the motor reference speed.
• Reduce the moment of inertia ratio.
• Reduce the number of times of the
DB stop operation.
The SERVOPACK or converter may be faulty. Replace the SERVOPACK or converter.
Reconnect the battery.
Replace the battery.
The SERVOPACK may be faulty.
Replace the SERVOPACK.
Use the correct parameter number.
Set the value of the parameter within the allowable range.
Set the value of the parameter within the allowable range.
9.2 Warning Displays
(cont’d)
A.94E
Data Setting
Warning 5
(Latch mode error)
A.95A
Command
Warning 1
(Unsatisfying
Command)
A.95B
Command
Warning 2
(Non-supported
Command)
A.95D
Command
Warning 4
(Command Interference)
A.95E
Command
Warning 5
(Subcommand
Disable)
A.95F
Command
Warning 6
(Undefined Command)
Warning Number: Warning
Name (Warning
Description)
A.94D
Data Setting
Warning 4
(Parameter Size )
Cause Investigative Actions Corrective Actions
Parameter size set in command is incorrect.
Latch mode error is detected.
Refer to 9.3 Monitoring Communication Data on Occurrence of an Alarm or Warning to determine which command was the cause of the warning.
Refer to 9.3 Monitoring Communication Data on Occurrence of an Alarm or Warning to determine which command was the cause of the warning.
Use the correct parameter size.
Change the setting value of Pn850 or the LT_MOD data for the
LTMOD_ON command sent by the host controller to the proper value.
Command sending condition is not satisfied.
SERVOPACK received unsupported command.
Refer to 9.3 Monitoring Communication Data on Occurrence of an Alarm or Warning to determine which command was the cause of the warning.
Refer to 9.3 Monitoring Communication Data on Occurrence of an Alarm or Warning to determine which command was the cause of the warning.
Send a command after command sending condition is satisfied.
Do not sent an unsupported command.
Command sending condition for latch-related commands is not satisfied.
Subcommand sending condition is not satisfied.
Refer to 9.3 Monitoring Communication Data on Occurrence of an Alarm or Warning to determine which command was the cause of the warning.
Refer to 9.3 Monitoring Communication Data on Occurrence of an Alarm or Warning to determine which command was the cause of the warning.
Send a command after command sending condition is satisfied.
Send a command after command sending condition is satisfied.
Undefined command was sent.
Refer to 9.3 Monitoring Communication Data on Occurrence of an Alarm or Warning to determine which command was the cause of the warning.
Do not use an undefined command.
A.960
MECHATROLINK
Communications
Warning
MECHATROLINK wiring is incorrect.
MECHATROLINK data reception error occurred due to noise interference.
Confirm the wiring.
Confirm the installation conditions.
Correct the MECHATROLINK wiring.
Or, connect a terminal to the terminal station.
Take measures against noise. Check the MECHATROLINK communications cable and FG wiring and take measures such as adding ferrite core on the MECHATROLINK communications cable.
A fault occurred in the
SERVOPACK.
–
A fault occurred in the SERVOPACK.
Replace the SERVOPACK.
9
9-25
9-26
9 Troubleshooting
9.2.2 Troubleshooting of Warnings
(cont’d)
Warning Number: Warning
Name (Warning
Description)
A.971:
Undervoltage
Cause Investigative Actions
The AC power supply voltage dropped to:
• 140 V or less for 200-
VAC SERVOPACKs.
• 280 V or less for 400-
VAC SERVOPACKs.
Measure the power supply voltage.
The power supply voltage dropped during operation.
Occurrence of instantaneous power interruption.
A fault occurred in the
SERVOPACK or converter.
Measure the power supply voltage.
Measure the power supply voltage.
−
A.9A0:
Overtravel
(Overtravel status is detected.)
When the servomotor power is ON, overtravel status is detected.
Check the input signal monitor
(Un005) to check the status of the overtravel signals.
Corrective Actions
Set the power supply voltage within the specified range.
Increase the power supply capacity.
When the instantaneous power cut hold time (Pn509) is set, decrease the setting.
The SERVOPACK or converter may be faulty. Replace the SERVOPACK or converter.
Refer to 9.4 Troubleshooting Malfunction Based on Operation and Conditions of the Servomotor . Even if overtravel signals were not shown by the input signal monitor (Un005), momentary overtravel may have been detected. Take the following precautions.
• Do not specify movements that would cause overtravel from the host controller.
• Check the wiring of the overtravel signals.
• Take countermeasures for noise.
9.3 Monitoring Communication Data on Occurrence of an Alarm or Warning
9.3
Monitoring Communication Data on Occurrence of an Alarm or
Warning
The command data received on occurrence of an alarm or warning, such as a data setting warning (A.94 ) or a command warning (A.95 ) can be monitored using the following parameters. The following is an example of the data when an alarm/warning has occurred in the normal state.
Command Data Monitor at Alarm/Warning Occurrence: Pn890 to Pn89E
Response Data Monitor at Alarm/Warning Occurrence: Pn8A0 to Pn8AE
Command
Byte Order
1
2
3
4
5 to 8
9 to 12
13 to 16
17 to 20
21 to 24
25 to 28
29 to 32
Command Data Storage at
Alarm/Warning Occurrence
CMD
Pn890.1 to 0
RSP
Pn8A0.1 to 0
Pn890.3 to 2
Pn890.5 to 4
Pn890.7 to 6
Pn892
Pn8A0.3 to 2
Pn8A0.5 to 4
Pn8A0.7 to 6
Pn8A2
Pn894
Pn896
Pn898
Pn89A
Pn89C
Pn89E
Pn8A4
Pn8A6
Pn8A8
Pn8AA
Pn8AC
Pn8AE
Example: Pn8A0 = 87 65 43 21
Note 1. Data is stored in little endian byte order and displayed in the hexadecimal format.
2. For details on commands, refer to Σ -V Series User’s Manual MECHATROLINK-II Commands (No.: SIEP
S800000 54)
9
9-27
9-28
9 Troubleshooting
9.4
Troubleshooting Malfunction Based on Operation and
Conditions of the Servomotor
Troubleshooting for the malfunctions based on the operation and conditions of the servomotor is provided in this section.
Be sure to turn OFF the servo system before troubleshooting items shown in bold lines in the table.
Problem
Servomotor Does
Not Start
Probable Cause
The control power supply is not
ON.
The main circuit power supply is not ON.
Wiring of I/O signal connector CN1 is faulty or disconnected.
Wiring for servomotor main circuit cable or encoder cable is disconnected.
Investigative Actions
Check voltage between control power terminals.
Check the voltage between main circuit power terminals.
Check if the connector CN1 is properly inserted and connected.
Check the wiring.
Overloaded
Encoder type differs from parameter setting (Pn002.2).
Settings for the input signal selections (Pn50A, Pn50B and Pn511) is incorrect.
Run under no load and check the load status.
Check the settings for parameter
Pn002.2.
Check the settings for parameters
Pn50A, Pn50B and Pn511.
SV_ON command is not sent.
SENS_ON command is not sent.
Check the command sent from the host controller.
Check the command sent from the host controller.
The forward run prohibited (P-OT) and reverse run prohibited (N-OT) input signals are turned OFF.
Check P-OT or N-OT input signal.
The safety input signal (/HWBB1 or
/HWBB2) remains OFF.
The brake is not released.
A fault occurred in the SERVO-
PACK or converter.
Servomotor wiring is incorrect.
Correct the wiring so that the control power supply turns ON.
Correct the wiring so that the main circuit power supply turns ON.
Correct the connector CN1 connection.
Corrective Actions
Correct the wiring.
Reduce load or replace with larger capacity servomotor.
Set parameter Pn002.2 to the encoder type being used.
Correct the settings for parameter
Pn50A, Pn50B and Pn511.
Send the SV_ON command.
Send the command in the correct
SERVOPACK sequence.
Turn P-OT or N-OT input signal
ON.
Check the /HWBB1 and /HWBB2 input signal.
Set the /HWBB1 and /HWBB2 input signal to ON.
When not using the safety function, mount the safety function jumper connector (provided as an accessory) on the CN8.
Check the operation of the brake.
Release the brake.
−
Check the wiring.
Replace the SERVOPACK or converter.
Correct the wiring.
Servomotor
Moves
Instantaneously, and then Stops
Encoder wiring is incorrect.
Check the wiring.
Correct the wiring.
Servomotor
Speed Unstable
Wiring connection to servomotor is defective.
Check connections of power line
(phases U, V, and W) and encoder connectors.
Tighten any loose terminals or connectors and correct the wiring.
Servomotor
Rotates Without
Reference Input
A fault occurred in the SERVO-
PACK.
− Replace the SERVOPACK.
9.4 Troubleshooting Malfunction Based on Operation and Conditions of the Servomotor
Problem
Dynamic Brake
Does Not Operate
Probable Cause
Improper Pn001.0 setting
DB resistor disconnected
DB drive circuit fault
Investigative Actions
Check the setting for parameter
Pn001.0.
Check if excessive moment of inertia, motor overspeed, or DB frequently activated occurred.
−
(cont’d)
Corrective Actions
Correct the setting for parameter
Pn001.0.
Replace the dynamic brake unit or change the external dynamic brake circuit. And reduce the load.
A defective component is in the dynamic brake circuit inside SER-
VOPACK. Replace the SERVO-
PACK.
Wiring of the dynamic brake unit is incorrect.
Check the wiring.
Correct the wiring.
9
9-29
9-30
9 Troubleshooting
Problem
Abnormal Noise from Servomotor
The servomotor largely vibrated during execution of tuning-less function.
Vibration source at the driven machine.
Probable Cause
Mounting is not secured.
Mounting is not secured.
Bearings are defective.
Noise interference due to incorrect
I/O signal cable specifications.
Noise interference due to length of
I/O signal cable.
Noise interference due to incorrect cable specifications of encoder cable.
Noise interference due to length of encoder cable.
Investigative Actions
Check the motor speed waveform.
(cont’d)
Corrective Actions
Reduce the load so that the moment of inertia ratio becomes within the allowable value, or increase the load level or lower the tuning level for the tuning-less levels setting
(Fn200).
Check if there are any loose mounting screws.
Check if there is misalignment of couplings.
Check if there are unbalanced couplings.
Check for noise and vibration around the bearings.
Check for any foreign matter, damage, or deformations on the machinery's movable parts.
The I/O signal cable must be tinned annealed copper shielded twistedpair or screened unshielded twistedpair cable with a core of 0.12 mm
2 min.
Check the length of the I/O signal cable.
The encoder cable must be tinned annealed copper shielded twistedpair or screened unshielded twistedpair cable with a core of 0.12 mm
2 min.
Tighten the mounting screws.
Align the couplings.
Balance the couplings.
Replace the servomotor.
Contact the machine manufacturer.
Use the specified I/O signal cable.
The I/O signal cable length must be no more than 3 m.
Use the specified encoder cable.
Check the length of the encoder cable.
The encoder cable must be no more than 50 m.
Noise interference due to damaged encoder cable.
Excessive noise to the encoder cable.
Check if the encoder cable is bent and the sheath is damaged.
Check if the encoder cable is bundled with a high-current line or near a high-current line.
Replace the encoder cable and correct the cable layout.
• Correct the cable layout so that no surge is applied.
• Use a double-shielded encoder cable.
The FG potential varies because of influence from machines on the servomotor side, such as the welder.
Check if the machines are correctly grounded.
Properly ground the machines to separate from the encoder FG.
SERVOPACK pulse counting error due to noise interference
Excessive vibration and shock to the encoder
An encoder fault occurred.
Check if there is noise interference on the I/O signal line from the encoder.
Check if vibration from the machine occurred or servomotor installation is incorrect (mounting surface accuracy, fixing, alignment, etc.).
−
Take measures against noise in the encoder wiring.
Reduce vibration from the machine, or secure the servomotor installation.
Replace the servomotor.
9.4 Troubleshooting Malfunction Based on Operation and Conditions of the Servomotor
Problem
Servomotor
Vibrates at
Frequency of
Approx. 200 to
400 Hz.
High Motor Speed
Overshoot on
Starting and
Stopping
Unbalanced servo gains
Speed loop gain value (Pn100) too high.
Position loop gain value (Pn102) too high.
(Pn103)
Probable Cause
Incorrect speed loop integral time constant (Pn101)
Incorrect moment of inertia ratio
Unbalanced servo gains
Speed loop gain value (Pn100) too high
Position loop gain value (Pn102) too high
Incorrect speed loop integral time constant (Pn101)
Incorrect moment of inertia ratio data (Pn103)
The torque reference is saturated.
Investigative Actions
Check to see if the servo gains have been correctly adjusted.
Check the speed loop gain (Pn100).
Factory setting: Kv = 40.0 Hz
Check the position loop gain
(Pn102).
Factory setting: Kp = 40.0/s
Check the speed loop integral time constant (Pn101).
Factory setting: Ti = 20.0 ms
Check the moment of inertia ratio
(Pn103).
Check to see if the servo gains have been correctly adjusted.
Check the speed loop gain (Pn100).
Factory setting: Kv = 40.0 Hz
Check the position loop gain
(Pn102).
Factory setting: Kp = 40.0/s
Check the speed loop integral time constant (Pn101).
Factory setting: Ti = 20.0 ms
Check the moment of inertia ratio
(Pn103).
Check the torque reference waveform.
(cont’d)
Corrective Actions
Execute the advanced autotuning.
Reduce the speed loop gain
(Pn100).
Reduce the position loop gain
(Pn102).
Correct the speed loop integral time constant (Pn101).
Correct the moment of inertia ratio
(Pn103).
Execute the advanced autotuning.
Reduce the speed loop gain
(Pn100).
Reduce the position loop gain
(Pn102).
Correct the speed loop integral time constant (Pn101).
Correct the moment of inertia ratio
(Pn103).
Use a mode switch.
9
9-31
9-32
9 Troubleshooting
Problem Probable Cause
Noise interference due to incorrect cable specifications of encoder cable.
Noise interference due to length of encoder cable.
Investigative Actions
The encoder cable must be tinned annealed copper shielded twistedpair or screened unshielded twistedpair cable with a core of 0.12 mm
2 min.
(cont’d)
Corrective Actions
Use the specified encoder cable.
Check the length of the encoder cable.
The encoder cable must be no more than 50 m.
Noise interference due to damaged encoder cable.
Check if the encoder cable is bent and the sheath is damaged.
Absolute
Encoder Position
Difference Error
(The position saved in the host controller when the power was turned OFF is different from the position when the power was next turned ON.)
Excessive noise to the encoder cable.
FG potential varies because of influence of machines such as welders at the servomotor.
SERVOPACK pulse counting error due to noise interference
Excessive vibration and shock to the encoder
An encoder fault occurred.
A fault occurred in the SERVO-
PACK.
Host controller multiturn data reading error
Check if the encoder cable is bundled with a high-current line or near a high-current line.
Check if the machines are correctly grounded.
Check if there is noise interference on the I/O signal line from the encoder.
Check if vibration from the machine occurred or servomotor installation is incorrect (mounting surface accuracy, fixing, alignment, etc.).
−
−
Check the error detection section of the host controller.
Check if the host controller is executing data parity checks.
Check noise in the cable between the SERVOPACK and the host controller.
Replace the encoder cable and correct the cable layout.
• Correct the cable layout so that no surge is applied.
• Use a double-shielded encoder cable.
Ground machines correctly, and prevent diversion to the FG on the encoder side.
Take measures against noise in the encoder wiring.
Reduce vibration from the machine, or secure the servomotor installation.
Replace the servomotor.
Replace the SERVOPACK.
Correct the error detection section of the host controller.
Execute a multiturn data parity check.
Take measures against noise, and again execute a multiturn data parity check.
9.4 Troubleshooting Malfunction Based on Operation and Conditions of the Servomotor
Problem
Overtravel (OT)
Improper Stop
Position by
Overtravel (OT)
Signal
Incorrect forward or reverse run prohibited signal (P-OT/N-OT) allocation (parameters Pn50A.3,
Pn50B.0)
Incorrect servomotor stop method selection
Probable Cause
Forward or reverse run prohibited signal is input.
Forward or reverse run prohibited signal malfunctioning.
Improper limit switch position and dog length
The overtravel limit switch position is too short for the coasting distance.
−
−
Investigative Actions
Check the external power supply
(+24 V) voltage for the input signal.
Check if the overtravel limit switch operates properly.
Check if the overtravel limit switch is wired correctly.
Check the settings for parameters
Pn50A and Pn50B.
Check the fluctuation of the external power supply (+24 V) voltage for the input signal.
Check if the overtravel limit switch operates correctly.
Check if the overtravel limit switch wiring is correct. (check for damaged cables or loose screws.)
Check if the P-OT signal is allocated in Pn50A.3.
Check if the N-OT signal is allocated in Pn50B.0.
Check the settings for parameters
Pn001.0 and Pn001.1 when the servomotor power is OFF.
Check the settings for parameters
Pn001.0 and Pn001.1 when in torque control.
(cont’d)
Corrective Actions
Correct the external power supply
(+24 V) voltage.
Correct the overtravel limit switch.
Correct the overtravel limit switch wiring.
Correct the settings for parameters
Pn50A and Pn50B.
Stabilize the external power supply
(+24 V) voltage.
Correct the overtravel limit switch.
Correct the overtravel limit switch wiring.
If another signal is allocated in
Pn50A.3, allocate P-OT.
If another signal is allocated in
Pn50B.0, allocate N-OT.
Select a servomotor stop method other than "coast to stop."
Select a servomotor stop method other than "coast to stop."
Install the limit switch at the appropriate position.
Install the overtravel limit switch at the appropriate position.
9
9-33
9-34
9 Troubleshooting
Problem
Position Error
(Without Alarm)
Servomotor
Overheated
Probable Cause
Noise interference due to incorrect encoder cable specifications
Noise interference due to length of encoder cable.
Investigative Actions
The encoder cable must be tinned annealed copper shielded twistedpair or screened unshielded twistedpair cable with a core of 0.12 mm
2 min.
(cont’d)
Corrective Actions
Use the specified encoder cable.
Check the length of the encoder cable.
The encoder cable must be no more than 50 m.
Noise influence due to damaged encoder cable.
Excessive noise to encoder cable.
Check if the encoder cable is bent and the sheath is damaged.
Check if the encoder cable is bundled with a high-current line or near a high-current line.
Replace the encoder cable and modify the cable layout.
• Change the cable layout so that no surge is applied.
• Use a double-shielded encoder cable.
The FG potential varies because of influence from machines on the servomotor side such as the welder.
SERVOPACK pulse count error due to noise
Excessive vibration and shock to the encoder
Unsecured coupling between machine and servomotor
Noise interference due to improper
I/O signal cable specifications
Check if the machines are correctly grounded.
Check if the I/O signal line from the encoder is influenced by noise.
Check if vibration from the machine occurred or servomotor installation is incorrect (mounting surface accuracy, fixing, alignment, etc.).
Check if a position error occurs at the coupling between machine and servomotor.
The I/O signal cable must be tinned annealed copper shielded twistedpair or screened unshielded twistedpair cable with a core of 0.12 mm
2 min.
Properly ground the machines encoder FG.
Take measures against noise in the encoder wiring.
Reduce the machine vibration or mount the servomotor securely.
Secure the coupling between the machine and servomotor.
Use input signal cable with the specified specifications.
Noise interference due to length of
I/O signal cable
An encoder fault occurred. (The pulse count does not change.)
A fault occurred in the SERVO-
PACK.
Ambient operating temperature too high
Servomotor surface dirty
Check the I/O signal cable length.
−
−
The I/O signal cable length must be no more than 3 m.
Replace the servomotor.
Replace the SERVOPACK.
Servomotor overloaded
A fault occurred in the fan.
Incorrect wiring of the fan.
The brake is not released.
Measure the servomotor ambient operating temperature.
Visually check the surface.
Reduce the ambient operating temperature to 40 ° C or less.
Clean dust and oil from the surface.
Check the load status with monitor.
If an overload occurs, reduce the load or replace the SERVOPACK, converter, and servomotor with models with higher capacities.
Check if the fan is rotating or not.
Replace the servomotor.
Check if the fan is rotating backward.
Check the wiring.
Correct the wiring.
Check the operation of the brake.
Release the brake.
10
Appendix
10.1 List of Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-2
10.1.1 Utility Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-2
10.1.2 Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-3
10.2 List of Monitor Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-34
10.3 Parameter Recording Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-35
10
10-1
10-2
10 Appendix
10.1.1 Utility Functions
10.1
List of Parameters
10.1.1
Utility Functions
The following list shows the available utility functions.
Fn201
Fn202
Fn203
Fn204
Fn205
Fn206
Fn207
Fn014
Fn01B
Fn01E
Fn01F
Fn020
Fn030
Fn200
Fn008
Fn00C
Fn00D
Fn00E
Fn00F
Fn010
Fn011
Fn012
Parameter
No.
Fn000
Fn002
Fn003
Fn004
Fn005
Fn006
Fn013
Function
Alarm history display
JOG operation
Origin search
Program JOG operation
Initializing parameter settings
Clearing alarm history
Absolute encoder multiturn reset and encoder alarm reset
Offset adjustment of analog monitor output
Gain adjustment of analog monitor output
Automatic offset-signal adjustment of the motor current detection signal
Manual offset-signal adjustment of the motor current detection signal
Write prohibited setting
Servomotor model display
Software version display
Multiturn limit value setting change when a multiturn limit disagreement alarm occurs
Resetting configuration error in option modules
Vibration detection level initialization
Display of SERVOPACK and servomotor ID
Display of servomotor ID in feedback option module
Origin setting
Software reset
Tuning-less levels setting
Advanced autotuning
Advanced autotuning by reference
One-parameter tuning
Anti-resonance control adjustment function
Vibration suppression function
EasyFFT
Online vibration monitor
4.7.4
6.8
6.9
6.10
6.11
6.12
6.13
6.14
Reference
Section
6.2
6.3
6.4
6.5
6.6
6.7
4.7.7
5.3.2
5.4.2
5.5.2
5.6.2
5.7.2
6.21
6.22
6.15
6.16
6.17
6.18
6.19
6.20
5.2.2
Note: Execute the utility function with either a digital operator or SigmaWin+. If they are used together, "no_oP" or "NO-
OP" will be displayed when the utility function is executed.
10.1 List of Parameters
10.1.2
Parameters
Parameter
No.
Size Name
2 Basic Function Select Switch 0 n.
4th 3rd 2nd 1st digit digit digit digit
Pn000
Setting
Range
0000 to
00B3
Units
−
Factory
Setting
0000
When
Enabled
After restart
Classification
Reference
Section
Setup −
Direction Selection
0
1
Sets CCW as forward direction.
Sets CW as forward direction. (Reverse Rotation Mode)
2 to 3 Reserved (Do not set.)
Reference
Section
4.3.1
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
Pn001
2 Application Function Select Switch 1 n.
4th 3rd 2nd 1st digit digit digit digit
0000 to 1122 − 0000 After restart Setup
Servomotor Power OFF or Alarm Gr.1 Stop Mode
0
1
2
Stops the servomotor by applying DB (dynamic brake).
Stops the servomotor by applying DB and then releases DB.
Makes the servomotor coast to a stop state without using the DB.
−
Reference
Section
4.3.5
Overtravel (OT) Stop Mode
0
1
2
Stops in accordance with the setting of Pn001.0.
Sets the torque of Pn406 to the maximum value, decelerates the servomotor to a stop, and then sets it to servolock state.
Sets the torque of Pn406 to the maximum value, decelerates the servomotor to a stop, and then sets it to coasting state.
Reference
Section
4.3.2
Reserved (Do not change.)
Reserved (Do not change.)
10
10-3
10-4
10 Appendix
10.1.2 Parameters
Parameter
No.
Size Name
2 Application Function Select Switch 2 n.
4th 3rd 2nd 1st digit digit digit digit
Setting
Range
0000 to 4113
Units
−
Factory
Setting
0000
When
Enabled
Classification
After restart Setup
(cont’d)
Reference
Section
−
MECHATROLINK Command Position and Speed Control Option
2
3
0
1
The set value of P_TLIM, NTLIM, and TFF are ignored.
P_TLIM and NTLIM operate as the torque limit values.
TFF operates as the torque feed forward.
When P-CL and N-CL in the OPTION field are available, P_TLIM and NTLIM operate as the torque limit value.
Reference
Section
*1
Pn002
Torque Control Option
0
1
VLIM is not available.
VLIM operates as the speed limit value.
Reference
Section
*1
Absolute Encoder Usage
0
1
Uses absolute encoder as an absolute encoder.
Uses absolute encoder as an incremental encoder.
Reference
Section
4.7
External Encoder Usage
0
Do not use external encoder.
*
1
2
Uses external encoder in standard rotation direction.
Reserved (Do not set.)
3 Uses external encoder in reverse rotation direction.
4 Reserved (Do not set.)
∗ The mode will be switched to semi-closed position control if Pn002.3 is set to 0.
Reference
Section
8.3.1
∗1.
For details, refer to Σ -V Series User’s Manual MECHATROLINK-II Commands (No.: SIEP S800000 54).
10.1 List of Parameters
Parameter
No.
Size Name
2 Application Function Select Switch 6 n.
4th 3rd 2nd 1st digit digit digit digit
Pn006
Setting
Range
0000 to 005F
Units
−
Factory
Setting
0002
When
Enabled
Classification
Immediately Setup
(cont’d)
Reference
Section
5.1.3
Analog Monitor 1 Signal Selection
00
Motor rotating speed (1 V/1000 min
-1
)
01
Speed reference (1 V/1000 min -1 )
02
03
04
05
Torque reference (1 V/100% rated torque)
Position error (0.05 V/1 reference unit)
Position amplifier error (after electronic gears) (0.05 V/1 encoder pulse unit)
Position reference speed (1 V/1000 min -1 )
06
07
08
09
0A
0B
0C
0D
Reserved (Do not set.)
Motor-load position error (0.01 V/1 reference unit)
Positioning completion (positioning completed: 5 V, positioning not completed: 0 V)
Speed feedforward (1 V/1000 min -1 )
Torque feedforward (1 V/100% rated torque)
Active gain (1st gain: 1 V, 2nd gain: 2 V)
Completion of position reference (completed: 5 V, not completed: 0 V)
External encoder speed (1 V/1000 min -1 : Values at motor shaft)
Reserved (Do not change.)
Reserved (Do not change.)
Pn007
2 Application Function Select Switch 7 n.
4th 3rd 2nd 1st digit digit digit digit
0000 to 005F − 0000 Immediately Setup
Analog Monitor 2 Signal Selection
00
Motor rotating speed (1 V/1000 min -1 )
01
02
03
04
05
Speed reference (1 V/1000 min -1 )
Torque reference (1 V/100% rated torque)
Position error (0.05 V/1 reference unit)
Position amplifier error (after electronic gears) (0.05 V/1 encoder pulse unit)
Position reference speed (1 V/1000 min
-1
)
Reserved (Do not set.) 06
07
08
09
Motor-load position error (0.01 V/1 reference unit)
Positioning completion (positioning completed: 5 V, positioning not completed: 0 V)
Speed feedforward (1 V/1000 min -1 )
0A Torque feedforward (1 V/100% rated torque)
0B Active gain (1st gain: 1 V, 2nd gain: 2 V)
0C
0D
Completion of position reference (completed: 5 V not completed: 0 V)
External encoder speed (1 V/1000 min -1 : Values at motor shaft)
Reserved (Do not change.)
Reserved (Do not change.)
5.1.3
10
10-5
10-6
10 Appendix
10.1.2 Parameters
Parameter
No.
Size Name
2 Application Function Select Switch 8 n.
4th 3rd 2nd 1st digit digit digit digit
Pn008
Setting
Range
0000 to 7121
Units
−
Factory
Setting
4000
When
Enabled
Classification
After restart Setup
(cont’d)
Reference
Section
−
Lowered Battery Voltage Alarm/Warning Selection
0
1
Outputs alarm (A.830) for lowered battery voltage.
Outputs warning (A.930) for lowered battery voltage.
Warning Detection Selection
0
1
Detects warning.
Does not detect warning (except for A.971).
Reserved (Do not change.)
Reference
Section
4.7.3
Function Selection for Undervoltage
0
1
2
Does not detect undervoltage.
Detects warning and limits torque by host controller.
Detects warning and limits torque by Pn424 and Pn425. (Only in the SERVOPACK)
Reference
Section
4.3.7
Reference
Section
9.2.1
0010 After restart Tuning −
Pn009
2 Application Function Select Switch 9 n.
4th 3rd 2nd 1st digit digit digit digit
0000 to 0111
Reserved (Do not change.)
Current Control Method Selection
0
1
Current control method 1
Current control method 2
Speed Detection Method Selection
0
1
Speed detection 1
Speed detection 2
Reserved (Do not change.)
−
Reference
Section
5.8.3
Reference
Section
5.8.5
10.1 List of Parameters
Parameter
No.
Size Name
2 Application Function Select Switch B n.
4th 3rd 2nd 1st digit digit digit digit
Setting
Range
0000 to 1111
Parameter Display Selection
0
1
Setup parameters
All parameters
Pn00B
Units
−
Factory
Setting
0000
When
Enabled
Classification
After restart Setup
(cont’d)
Reference
Section
−
Alarm Gr.2 Stop Method Selection
0
1
Stops the motor by setting the speed reference to "0".
Same setting as Pn001.0 (Stops the motor by applying DB or by coasting).
Reference
Section
2.4.1
Reference
Section
4.3.5
Reserved (Do not change.)
Reserved (Do not change.)
Pn00C
2 Application Function Select Switch C n.
4th 3rd 2nd 1st digit digit digit digit
0000 to 0111
Selection of Test without a Motor
0
1
Disables test without a motor.
Enables test without a motor.
−
Encoder Resolution for Test without a Motor
0
1
13 bits
20 bits
Encoder Type for Test without a Motor
0 Incremental encoder
1 Absolute encoder
Reserved (Do not change.)
0000 After restart Setup
4.5,
4.5.1
10
10-7
10-8
10 Appendix
10.1.2 Parameters
Pn100
Pn101
Pn102
Pn103
Pn104
Pn105
Pn106
Pn109
Pn10A
Parameter
No.
Size Name
2 Application Function Select Switch D n.
4th 3rd 2nd 1st digit digit digit digit
Setting
Range
0000 to 1011
Reserved (Do not change.)
Units
−
Factory
Setting
0000
When
Enabled
Classification
Immediately Setup
(cont’d)
Reference
Section
–
Reference
Section
Pn00D
Dynamic Brake Signal Selection
0
1
Enables the control of an NO contactor
(The dynamic brake is activated when current is supplied to the contactor coil.)
Enables the control of an NC contactor
(The dynamic brake is activated when current is not supplied to the contactor coil.)
Reserved (Do not change.)
3.9.3
Overtravel Warning Detection Selection
0
1
Does not detect overtravel warning.
Detects overtravel warning.
Reference
Section
4.3.2
0000 to 1111 − 0000 After restart Setup 8.1.5
2 Application Function Select Switch 81 n.
4th digit
3rd digit
2nd digit
1st digit
Pn081
Phase-C Pulse Output Selection
0
1
Outputs phase-C pulse only in forward direction.
Outputs phase-C pulse in forward and reverse direction.
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
2 Speed Loop Gain
2 Speed Loop Integral Time Constant
2 Position Loop Gain
2 Moment of Inertia Ratio
10 to 20000 0.1 Hz
15 to 51200 0.01 ms
10 to 20000
0 to 20000
0.1/s
1%
2 2nd Speed Loop Gain 10 to 20000 0.1 Hz
2 2nd Speed Loop Integral Time Constant 15 to 51200 0.01 ms
2 2nd Position Loop Gain
2 Feedforward Gain
2
Feedforward Filter Time
Constant
10 to 20000
0 to 100
0 to 6400
0.1/s
1%
0.01 ms
400
2000
400
100
400
2000
400
0
0
Immediately Tuning 5.8.1
Immediately Tuning 5.8.1
Immediately Tuning 5.8.1
Immediately Tuning 5.8.1
Immediately Tuning 5.8.1
Immediately Tuning 5.8.1
Immediately Tuning 5.8.1
Immediately Tuning 5.9.1
Immediately Tuning 5.9.1
10.1 List of Parameters
Pn10F
Pn11F
Pn121
Pn122
Pn123
Pn124
Pn125
Pn131
Pn132
Pn135
Pn136
Parameter
No.
Size Name
2
Application Function for Gain Select
Switch n.
4th 3rd 2nd 1st digit digit digit digit
Pn10B
Setting
Range
0000 to 5334
Units
−
Factory
Setting
0000
When
Enabled
−
Mode Switch Selection
0
1
2
3
4
Uses internal torque reference as the condition
(Level setting: Pn10C).
Uses speed reference as the condition (Level setting: Pn10D).
Uses acceleration as the condition (Level setting:
Pn10E).
Uses position error as the condition (Level setting:
Pn10F).
No mode switch function available.
When
Enabled
Immediately
Classification
Setup
Classification
(cont’d)
Reference
Section
− −
Reference
Section
5.9.2
When
Enabled
Classification
Reference
Section
Speed Loop Control Method
0 PI control
1 I-P control
2 to 3 Reserved (Do not set.)
Reserved (Do not change.)
After restart Setup −
Reserved (Do not change.)
Pn10C
Pn10D
Pn10E
2 Mode Switch (torque reference)
2 Mode Switch (speed reference)
2 Mode Switch (acceleration)
Immediately Tuning 5.9.2
Immediately Tuning 5.9.2
Immediately Tuning 5.9.2
2 Mode Switch (position error)
2
Position Integral Time
Constant
2 Friction Compensation Gain
2
2nd Gain for Friction
Compensation
2
2
Friction Compensation
Coefficient
Friction Compensation
Frequency Correction
2 Friction Compensation Gain Correction
2 Gain Switching Time 1
2 Gain Switching Time 2
2 Gain Switching Waiting Time 1
2 Gain Switching Waiting Time 2
0 to 800 1%
0 to 10000 1 min
-1
0 to 30000 1 min -1
/ s
0 to 10000
1 reference unit
0 to 50000 0.1 ms
10 to 1000 1%
10 to 1000 1%
200
0
0
0
0
100
100
0 0 to 100
-10000 to
10000
1 to 1000
0 to 65535
0 to 65535
0 to 65535
0 to 65535
1%
0.1 Hz
1%
1 ms
1 ms
1 ms
1 ms
0
100
0
0
0
0
Immediately Tuning 5.9.2
Immediately Tuning 5.8.7
Immediately Tuning 5.8.2
Immediately Tuning 5.8.2
Immediately Tuning 5.8.2
Immediately Tuning 5.8.2
Immediately Tuning 5.8.2
Immediately Tuning 5.8.1
Immediately Tuning 5.8.1
Immediately Tuning 5.8.1
Immediately Tuning 5.8.1
10
10-9
10 Appendix
10.1.2 Parameters
10-10
Parameter
No.
Size Name
2
Automatic Gain Changeover Related
Switch 1 n.
4th 3rd 2nd 1st digit digit digit digit
Setting
Range
0000 to 0052
Units
−
Factory
Setting
0000
When
Enabled
Classification
(cont’d)
Reference
Section
Immediately Tuning 5.8.1
Gain Switching Selection Switch
0
1
2
Manual gain switching
Changes gain manually using G-SEL of OPTION field.
Reserved (Do not set.)
Automatic gain switching pattern 1
Changes automatically 1st gain to 2nd gain when the switching condition A is satisfied.
Changes automatically 2nd gain to 1st gain when the switching condition A is not satisfied.
Pn139
Gain Switching Condition A
0
3
4
5
1
2
Positioning completion signal (/COIN) ON
Positioning completion signal (/COIN) OFF
Positioning near signal (/NEAR) ON
Positioning near signal (/NEAR) OFF
Position reference filter output = 0 and position reference input OFF
Position reference input ON
Reserved (Do not change.)
Reserved (Do not change.)
Pn13D
Pn140
Pn141
Pn142
Pn143
2 Current Gain Level 100 to 2000
2 Model Following Control Related Switch 0000 to 1121 n.
4th 3rd 2nd 1st digit digit digit digit
Model Following Control Selection
0
1
Does not use model following control.
Uses model following control.
1%
−
2000
0100
Immediately Tuning 5.8.4
Immediately Tuning −
Vibration Suppression Selection
0
1
2
Does not perform vibration suppression.
Performs vibration suppression over the specified frequency.
Performs vibration suppression over two different kinds of frequencies.
Vibration Suppression Adjustment Selection
0
1
Does not adjust vibration suppression automatically using utility function.
Adjusts vibration suppression automatically using utility function.
Selection of Speed Feedforward (VFF) / Torque Feedforward (TFF)
0
1
Does not use model following control and speed/torque feedforward together.
Uses model following control and speed/torque feedforward together.
Reference
Section
5.3.1, 5.4.1,
5.5.1, 5.7.1
Reference
Section
5.3.1, 5.4.1
2 Model Following Control Gain
2
2
Model Following Control Gain Compensation
Model Following Control Bias
(Forward Direction)
10 to 20000
500 to 2000
0 to 10000
0.1/s
0.1%
0.1%
500
1000
1000
Immediately Tuning
Immediately Tuning
Immediately Tuning
−
−
−
10.1 List of Parameters
Parameter
No.
Size
Pn144
Pn145
Pn146
Pn147
Pn148
Pn149
Pn14A
Pn14B
Name
2
2
2
Model Following Control Bias
(Reverse Direction)
Vibration Suppression 1
Frequency A
Vibration Suppression 1
Frequency B
2
Model Following Control Speed Feedforward
Compensation
2 2nd Model Following Control Gain
2
2
2nd Model Following Control Gain Compensation
Vibration Suppression 2
Frequency
2 Vibration Suppression 2 Compensation
2 Control Related Switch
Setting
Range
0 to 10000
10 to 2500
10 to 2500
0 to 10000
10 to 20000
500 to 2000
10 to 2000
10 to 1000
0000 to 0011 n.
4th 3rd 2nd 1st digit digit digit digit
Units
0.1%
0.1 Hz
0.1 Hz
0.1%
0.1/s
0.1%
0.1 Hz
1%
-
Model Following Control Type Selection
0 Model Following Control 1
1
Model Following Control 2
Pn14F
Tuning-less Type Selection
0 Tuning-less type 1
1 Tuning-less type 2
Reserved (Do not change.)
Reserved (Do not change.)
Factory
Setting
1000
When
Enabled
Immediately
Classification
(cont’d)
Reference
Section
Tuning −
500 Immediately Tuning
700 Immediately Tuning
−
−
1000
500
1000
800
100
0011
Immediately Tuning
Immediately Tuning
Immediately Tuning
Immediately Tuning
Immediately Tuning
After restart Tuning
−
−
−
−
−
–
Reference
Section
5.3.1,
5.4.1,
5.5.1
Reference
Section
5.2.2
2 Anti-Resonance Control Related Switch 0000 to 0011 − 0010 Immediately Tuning
5.3.1,
5.4.1,
5.5.1,
5.7.1
n.
4th 3rd 2nd 1st digit digit digit digit
Pn160
Anti-Resonance Control Selection
0 Does not use anti-resonance control.
1 Uses anti-resonance control.
Anti-Resonance Control Adjustment Selection
0
1
Does not adjust anti-resonance control automatically using utility function.
Adjusts anti-resonance control automatically using utility function.
Reserved (Do not change.)
Reserved (Do not change.)
Pn161 2 Anti-Resonance Frequency 10 to 20000 0.1 Hz 1000 Immediately Tuning −
10
10-11
10 Appendix
10.1.2 Parameters
10-12
Parameter
No.
Size
Pn162
Pn163
Pn164
Pn165
Name
2
Anti-Resonance Gain
Compensation
2 Anti-Resonance Damping Gain
2
Anti-Resonance Filter Time Constant 1
Compensation
2
Anti-Resonance Filter Time Constant 2
Compensation
2 Tuning-less Function Related Switch n.
4th 3rd 2nd 1st digit digit digit digit
Pn170
Setting
Range
1 to 1000
Units
0 to 300
-1000 to
1000
-1000 to
1000
0000 to 2411
1%
1%
0.01 ms
0.01 ms
−
Factory
Setting
100
0
0
When
Enabled
Immediately
Immediately
Immediately
Classification
(cont’d)
Reference
Section
Tuning
Tuning
Tuning
−
−
−
0
1401
Immediately
−
Tuning
–
−
–
Tuning-less Function Selection
0
1
Disables tuning-less function.
Enables tuning-less function.
When
Enabled
After restart
Classification
Setup
Reference
Section
5.2
Control Method during Speed Control
0 Uses as speed control.
1
Uses as speed control and uses the host controller for position control.
When
Enabled
After restart
Classification
Setup
Reference
Section
5.2
Rigidity Level
0 to 4 Sets rigidity level.
Load Level
0 to 2 Sets load level.
When
Enabled
Immediately
Classification
Setup
Reference
Section
5.2
When
Enabled
Immediately
Classification
Setup
Reference
Section
5.2
Pn205 1 rev
−
65535
0010
After restart Setup
After restart Setup
4.7.6
−
2 Multiturn Limit Setting
2 Position Control Function Switch n.
4th 3rd 2nd 1st digit digit digit digit
0 to 65535
0000 to 2210
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
Pn207
Reference
Section
/COIN Output Timing
0
1
2
Outputs when the position error absolute value is the same or less than the positioning completed width (Pn522).
Outputs when the position error absolute value is the same or less than the positioning completed width (Pn522), and the reference after position reference filtering is 0.
Outputs when the position error absolute value is the same or less than the positioning completed width (Pn522), and the position reference input is 0.
4.8.6
Pn20A
Pn20E
4 Number of External Scale Pitch
4 Electronic Gear Ratio (Numerator)
4 to 1048576
1 pitch/rev
1 to
1073741824
1
32768
4
After restart Setup
After restart Setup
8.3
4.4.3
10.1 List of Parameters
Pn231
Pn233
Pn281
Pn304
Pn305
Pn306
Parameter
No.
Size
Pn210
Name
4 Electronic Gear Ratio (Denominator)
Pn212 4 Encoder Output Pulses
2
Fully-closed Control
Selection Switch n.
4th 3rd 2nd 1st digit digit digit digit
Pn22A
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
Setting
Range
1 to
1073741824
16 to
1073741824
0000 to 1003
Units
1
1 P/rev
−
Factory
Setting
1
When
Enabled
Classification
After restart Setup
(cont’d)
Reference
Section
4.4.3
2048
0000
After restart
After restart
Setup
Setup
4.4.5
−
Speed Feedback Selection at Fully-closed Control
0
1
Uses motor encoder speed.
Uses external encoder speed.
Reference
Section
8.3.8
Pn230
2
Position Control Expanded Function
Switch n.
4th 3rd 2nd 1st digit digit digit digit
0000 to 0001 – 0000
Backlash Compensation Direction
0 Compensates with a reference in the forward direction.
1 Compensates with a reference in the reverse direction.
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
After reset Setup 5.8.6
4 Backlash Compensation Value
2 Backlash Compensation Time Constant
2 Encoder Output Resolution
2 JOG Speed
-500000 to
500000
0.1 reference unit
0 to 65536 0.01 ms
1 to 4096
1 edge/ pitch
0 to 10000 1 min
-1
0
0
20
500
Immediately Setup
Immediately Setup
After restart Setup
Immediately Setup
2 Soft Start Acceleration Time 0 to 10000 1 ms 0 Immediately Setup
2 Soft Start Deceleration Time 0 to 10000 1 ms 0 Immediately Setup
∗1.
For details, refer to Σ -V Series User’s Manual MECHATROLINK-II Commands (No.: SIEP S800000 54).
5.8.6
5.8.6
8.3.3
6.3
*1
*1
10
10-13
10 Appendix
10.1.2 Parameters
Pn311
Pn312
Pn324
Pn401
Pn402
Pn403
Pn404
Pn405
Pn406
Pn407
Parameter
No.
Size Name
2 Vibration Detection Switch n.
4th 3rd 2nd 1st digit digit digit digit
Pn310
Setting
Range
0000 to 0002
Units
−
Factory
Setting
0000
When
Enabled
Classification
Immediately Setup
(cont’d)
Reference
Section
−
Vibration Detection Selection
0
1
2
Does not detect vibration.
Outputs warning (A.911) when vibration is detected.
Outputs alarm (A.520) when vibration is detected.
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
2
Vibration Detection
Sensibility
50 to 500 1%
2 Vibration Detection Level 0 to 5000 1 min
-1
2 Moment of Inertia Calculating Start Level 0 to 20000 1%
2 Torque Reference Filter Time Constant 0 to 65535 0.01 ms
2 Forward Torque Limit
2 Reverse Torque Limit
2 Forward External Torque Limit
2 Reverse External Torque Limit
2 Emergency Stop Torque
2 Speed Limit during Torque Control
0 to 800 1%
0 to 800 1%
0 to 800
0 to 800
1%
1%
0 to 800 1%
0 to 10000 1 min
-1
Reference
Section
6.16
100 Immediately Tuning 6.16
50
300
100
800
Immediately Tuning
Immediately Setup
Immediately
Immediately
Tuning
Setup
800 Immediately Setup
100
100
800
Immediately
Immediately
Immediately
Setup
Setup
Setup
10000 Immediately Setup
6.16
5.3.2
5.9.3
4.6.1
4.6.1
4.6.2
4.6.2
4.3.2
4.8.8
10-14
10.1 List of Parameters
Pn409
Pn40A
Pn40B
Pn40C
Pn40D
Pn40E
Pn40F
Pn410
Pn412
Pn415
Pn423
Pn424
Pn425
Pn456
Parameter
No.
Size Name
2
Torque Related
Function Switch n.
4th 3rd 2nd 1st digit digit digit digit
Pn408
Setting
Range
0000 to 1111
Units
−
Factory
Setting
0000
When
Enabled
−
Classification
(cont’d)
Reference
Section
− −
1st Step Notch Filter Selection
0
1
N/A
Uses 1st step notch filter for torque reference.
When
Enabled
Immediately
Classification
Setup
Reference
Section
5.9.3
Speed Limit Selection
0
1
Uses the smaller of the maximum motor speed and the value of Pn407 as the speed limit value.
Uses the smaller of the overspeed detection speed and the value of Pn407 as the speed limit value.
When
Enabled
After restart
Classification
Setup
Reference
Section
4.8.8
2nd Step Notch Filter Selection
0
1
N/A
Uses 2nd step notch filter for torque reference.
When
Enabled
Immediately
Classification
Setup
Reference
Section
5.9.3
Friction Compensation Function Selection
0
1
Disables friction compensation function.
Enables friction compensation function.
When
Enabled
Immediately
Classification
Setup
Reference
Section
5.8.2
2 1st Notch Filter Frequency
2 1st Notch Filter Q Value
2 1st Notch Filter Depth
2 2nd Notch Filter Frequency
2 2nd Notch Filter Q Value
2 2nd Notch Filter Depth
2
2nd Step 2nd Torque Reference Filter
Frequency
2
2
2nd Step 2nd Torque Reference Filter Q
Value
1st Step 2nd Torque Reference Filter
Time
Constant
2 Reserved (Do not change.)
2 Reserved (Do not change.)
2
2
Torque Limit at Main Circuit Voltage
Drop
Release Time for Torque Limit at Main
Circuit Voltage Drop
2 Sweep Torque Reference Amplitude
50 to 5000
50 to 1000
0 to 1000
50 to 5000
50 to 1000
0 to 1000
100 to 5000
50 to 100
0 to 65535
−
−
0 to 100
0 to 1000
1 to 800
0.01
0.01 ms
−
−
1%
1 ms
1%
1 Hz
0.01
0.001
1 Hz
0.01
0.001
1 Hz
5000
70
0
5000
70
0
5000
50
100
0
0000
50
100
15
Immediately Tuning 5.9.3
Immediately Tuning 5.9.3
Immediately Tuning 5.9.3
Immediately Tuning 5.9.3
Immediately Tuning 5.9.3
Immediately Tuning 5.9.3
Immediately Tuning 5.9.3
Immediately Tuning 5.9.3
Immediately Tuning 5.8.1
−
−
−
−
Immediately Setup
−
−
4.3.7
Immediately Setup
Immediately Tuning
4.3.7
6.21
10
10-15
10 Appendix
10.1.2 Parameters
Pn501
Pn502
Pn503
Pn506
Pn507
Pn508
Pn509
Parameter
No.
Size Name
2 Notch Filter Adjustment Switch
Pn460
Setting
Range
0000 to 0101
Units
−
Factory
Setting
0101
When
Enabled
Immediately
Classification
Tuning
(cont’d)
Reference
Section
5.2.1
5.3.1
5.5.1
n.
4th 3rd 2nd 1st digit digit digit digit
Notch Filter Adjustment Selection 1
0
1
Does not adjust 1st step notch filter automatically using utility function.
Adjust 1st step notch filter automatically using utility function.
Reserved (Do not change.)
Notch Filter Adjustment Selection 2
0 Does not adjust 2nd step notch filter automatically using utility function.
1 Adjust 2nd step notch filter automatically using utility function.
Reserved (Do not change.)
2 Zero Clamp Level
2 Rotation Detection Level
2 Speed Coincidence Signal Output Width
2 Brake Reference - Servo OFF Delay Time
2 Brake Reference Output Speed Level
2
Waiting Time for Brake
Signal When Motor Running
2 Instantaneous Power Cut Hold time
0 to 10000 1 min
1 to 10000 1 min
0 to 100
0 to 50
10 to 100
20 to 50000 1 ms
-1
-1
1 min
-1
10 ms
0 to 10000 1 min
-1
10 ms
10
20
10
0
100
50
20
Immediately
Immediately
Immediately
Immediately Setup
Immediately Setup
Immediately
Immediately
Setup
Setup
Setup
Setup
Setup
−
4.8.3
4.8.5
4.3.4
4.3.4
4.3.4
4.3.6
10-16
10.1 List of Parameters
Parameter
No.
Size Name
2 Input Signal Selection 1 n.
4th 3rd 2nd 1st digit digit digit digit
Setting
Range
0000 to
FFF1
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
Pn50A
Units
−
Factory
Setting
2881
When
Enabled
After restart
Classification
(cont’d)
Reference
Section
Setup −
P-OT Signal Mapping (Forward run prohibited when OFF (open))
A
B
C
D
E
F
6
7
8
9
2
3
0
1
4
5
Forward run allowed when CN1-40 input signal is ON (closed).
Forward run allowed when CN1-41 input signal is ON (closed).
Forward run allowed when CN1-42 input signal is ON (closed).
Forward run allowed when CN1-43 input signal is ON (closed).
Forward run allowed when CN1-44 input signal is ON (closed).
Forward run allowed when CN1-45 input signal is ON (closed).
Forward run allowed when CN1-46 input signal is ON (closed).
Forward run prohibited.
Forward run allowed.
Forward run allowed when CN1-40 input signal is OFF (open).
Forward run allowed when CN1-41 input signal is OFF (open).
Forward run allowed when CN1-42 input signal is OFF (open).
Forward run allowed when CN1-43 input signal is OFF (open).
Forward run allowed when CN1-44 input signal is OFF (open).
Forward run allowed when CN1-45 input signal is OFF (open).
Forward run allowed when CN1-46 input signal is OFF (open).
Reference
Section
4.3.2
10
10-17
10 Appendix
10.1.2 Parameters
Parameter
No.
Size Name
2 Input Signal Selection 2 n.
4th 3rd 2nd 1st digit digit digit digit
Pn50B
Setting
Range
0000 to
FFFF
Units
–
Factory
Setting
8883
When
Enabled
Classification
After restart Setup
(cont’d)
Reference
Section
–
N-OT Signal Mapping (Reverse run prohibited when OFF (open))
9
A
B
C
5
6
7
8
D
E
F
2
3
4
0
1
Reverse run allowed when CN1-40 input signal is ON (closed).
Reverse run allowed when CN1-41 input signal is ON (closed).
Reverse run allowed when CN1-42 input signal is ON (closed).
Reverse run allowed when CN1-43 input signal is ON (closed) .
Reverse run allowed when CN1-44 input signal is ON (closed).
Reverse run allowed when CN1-45 input signal is ON (closed).
Reverse run allowed when CN1-46 input signal is ON (closed).
Reverse run prohibited.
Reverse run allowed.
Reverse run allowed when CN1-40 input signal is OFF (open).
Reverse run allowed when CN1-41 input signal is OFF (open).
Reverse run allowed when CN1-42 input signal is OFF (open).
Reverse run allowed when CN1-43 input signal is OFF (open).
Reverse run allowed when CN1-44 input signal is OFF (open).
Reverse run allowed when CN1-45 input signal is OFF (open).
Reverse run allowed when CN1-46 input signal is OFF (open).
Reserved (Do not change.)
/P-CL Signal Mapping (Torque Limit when ON (closed))
9
A
B
C
5
6
7
8
D
E
F
2
3
4
0
1
Active when CN1-40 input signal is ON (closed).
Active when CN1-41 input signal is ON (closed).
Active when CN1-42 input signal is ON (closed).
Active when CN1-43 input signal is ON (closed).
Active when CN1-44 input signal is ON (closed).
Active when CN1-45 input signal is ON (closed).
Active when CN1-46 input signal is ON (closed).
Always active (fixed).
Not active (fixed).
Active when CN1-40 input signal is OFF (open).
Active when CN1-41 input signal is OFF (open).
Active when CN1-42 input signal is OFF (open).
Active when CN1-43 input signal is OFF (open).
Active when CN1-44 input signal is OFF (open).
Active when CN1-45 input signal is OFF (open).
Active when CN1-46 input signal is OFF (open).
/N-CL Signal Mapping (Torque Limit when ON (closed))
0 to F Same as /P-CL signal mapping
Reference
Section
4.3.2
Reference
Section
4.6.2
Reference
Section
4.6.2
10-18
10.1 List of Parameters
Parameter
No.
Size Name
2 Output Signal Selection 1 n.
4th 3rd 2nd 1st digit digit digit digit
Setting
Range
0000 to 3333
Units
−
Factory
Setting
0000
When
Enabled
Classification
After restart Setup
(cont’d)
Reference
Section
−
Positioning Completion Signal Mapping (/COIN)
2
3
0
1
Disabled (the above signal is not used.)
Outputs the signal from CN1-25, -26 output terminal.
Outputs the signal from CN1-27, -28 output terminal.
Outputs the signal from CN1-29, -30 output terminal.
Reference
Section
4.8.6
Pn50E
Speed Coincidence Detection Signal Mapping (/V-CMP)
0 to 3 Same as /COIN Signal Mapping.
Reference
Section
4.8.5
Servomotor Rotation Detection Signal Mapping (/TGON)
0 to 3 Same as /COIN Signal Mapping.
Servo Ready Signal Mapping (/S-RDY)
0 to 3 Same as /COIN Signal Mapping.
Reference
Section
4.8.3
Reference
Section
4.8.4
Pn50F
2 Output Signal Selection 2 n.
4th 3rd 2nd 1st digit digit digit digit
0000 to 3333 − 0100
Torque Limit Detection Signal Mapping (/CLT)
2
3
0
1
Disabled (the above signal is not used.)
Outputs the signal from CN1-25, -26 output terminal.
Outputs the signal from CN1-27, -28 output terminal.
Outputs the signal from CN1-29, -30 output terminal.
After restart Setup
Reference
Section
4.6.3
−
Speed Limit Detection Signal Mapping (/VLT)
0 to 3 Same as /CLT Signal Mapping.
Brake Signal Mapping (/BK)
0 to 3 Same as /CLT Signal Mapping.
Warning Signal Mapping (/WARN)
0 to 3 Same as /CLT Signal Mapping.
Reference
Section
4.8.8
Reference
Section
4.3.4
Reference
Section
4.8.2
10
10-19
10 Appendix
10.1.2 Parameters
Parameter
No.
Size Name
2 Output Signal Selection 3 n.
4th 3rd 2nd 1st digit digit digit digit
Pn510
Setting
Range
0000 to 0333
Units
−
Factory
Setting
0000
When
Enabled
Classification
After restart Setup
(cont’d)
Reference
Section
−
Near Signal Mapping (/NEAR)
2
3
0
1
Disabled (the above signal is not used.)
Outputs the signal from CN1-25, -26 output terminal.
Outputs the signal from CN1-27, -28 output terminal.
Outputs the signal from CN1-29, -30 output terminal.
Reference
Section
4.8.7
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
10-20
10.1 List of Parameters
Parameter
No.
Size Name
2 Input Signal Selection 5 n.
4th 3rd 2nd 1st digit digit digit digit
Pn511
Setting
Range
0000 to
FFFF
Units
−
Factory
Setting
6541
When
Enabled
Classification
After restart Setup
(cont’d)
Reference
Section
3.4.1
9
A
B
5
6
7
8
Homing Deceleration Switch Signal Mapping (/DEC)
0
Active when CN1-40 input signal is ON (closed).
1
2
Active when CN1-41 input signal is ON (closed).
Active when CN1-42 input signal is ON (closed).
3
Active when CN1-43 input signal is ON (closed).
4
Active when CN1-44 input signal is ON (closed).
Active when CN1-45 input signal is ON (closed).
Active when CN1-46 input signal is ON (closed).
Always active (fixed).
Not active (fixed).
Active when CN1-40 input signal is OFF (open).
Active when CN1-41 input signal is OFF (open).
Active when CN1-42 input signal is OFF (open).
C
D
E
F
Active when CN1-43 input signal is OFF (open).
Active when CN1-44 input signal is OFF (open).
Active when CN1-45 input signal is OFF (open).
Active when CN1-46 input signal is OFF (open).
External Latch Signal Mapping (/EXT1)
4
5
6
7
8
D
E
F
0 to 3
9 to C
Active when CN1-10 input signal is ON (closed).
Active when CN1-11 input signal is ON (closed).
Active when CN1-12 input signal is ON (closed).
Always active (fixed).
Not active (fixed).
Active when CN1-10 signal is OFF (open).
Active when CN1-11 signal is OFF (open).
Active when CN1-12 signal is OFF (open).
Not active (fixed).
External Latch 2 Signal Mapping (/EXT2)
4 to 8
D to F
Same as /EXT1 signal mapping.
External Latch 3 Signal Mapping (/EXT3)
4 to 8
D to F
Same as /EXT1 signal mapping.
10
10-21
10 Appendix
10.1.2 Parameters
10-22
Parameter
No.
Size Name
2 Output Signal Inverse Setting n.
4th 3rd 2nd 1st digit digit digit digit
Setting
Range
0000 to 0111
Units
−
Output Signal Inversion for CN1-25 or -26 Terminal
0 Does not inverse outputs.
1 Inverses outputs.
Factory
Setting
0000
When
Enabled
Classification
After restart Setup
(cont’d)
Reference
Section
3.4.2
Pn512 Output Signal Inversion for CN1-27 or -28 Terminal
0 Does not inverse outputs.
1 Inverses outputs.
Output Signal Inversion for CN1-29 or -30 Terminal
0
1
Does not inverse outputs.
Inverses outputs.
Reserved (Do not change.)
Pn515
2 Input Signal Selection 6 n.
4th 3rd 2nd 1st digit digit digit digit
0000 to
FFFF
Reserved (Do not change.)
− 8888 After restart Setup −
Reserved (Do not change.)
Dynamic Brake Answer signal 1 Input Signal Mapping (/DBANS1)
0 Detects dynamic brake (DB) contactor errors when the input signal of CN1-40 is ON (closed) while the DB is applied.
C
D
E
F
3
4
1
2
5
6
Detects DB contactor errors when the input signal of CN1-41 is ON (closed) while the DB is applied.
Detects DB contactor errors when the input signal of CN1-42 is ON (closed) while the DB is applied.
Detects DB contactor errors when the input signal of CN1-43 is ON (closed) while the DB is applied.
Detects DB contactor errors when the input signal of CN1-44 is ON (closed) while the DB is applied.
Detects DB contactor errors when the input signal of CN1-45 is ON (closed) while the DB is applied.
Detects DB contactor errors when the input signal of CN1-46 is ON (closed) while the DB is applied.
7, 8 Disables DB contactor error detection of DB answer signal 1.
9 Detects DB contactor errors when the input signal of CN1-40 is OFF (open) while the DB is applied.
A
B
Detects DB contactor errors when the input signal of CN1-41 is OFF (open) while the DB is applied.
Detects DB contactor errors when the input signal of CN1-42 is OFF (open) while the DB is applied.
Detects DB contactor errors when the input signal of CN1-43 is OFF (open) while the DB is applied.
Detects DB contactor errors when the input signal of CN1-44 is OFF (open) while the DB is applied.
Detects DB contactor errors when the input signal of CN1-45 is OFF (open) while the DB is applied.
Detects DB contactor errors when the input signal of CN1-46 is OFF (open) while the DB is applied.
Reference
Section
3.9.4
Reserved (Do not change.)
Pn517
Pn51B
Pn51E
2
4
2
Reserved (Do not change.)
Excessive Error Level between Servomotor and Load Positions
0 to
1073741824
Excessive Position Error Warning Level
–
10 to 100
–
1 reference unit
1%
0000
1000
100
– –
Immediately Setup
Immediately Setup
–
8.3.6
9.2.1
10.1 List of Parameters
Parameter
No.
Pn520
Pn522
Pn524
Pn526
Pn528
Pn529
Pn52A
Pn52B
Pn52C
Pn52D
Pn52F
Size Name
Setting
Range
Units
4
4
4
4
Excessive Position Error Alarm Level
Positioning Completed Width
NEAR Signal Width
Excessive Position Error Alarm Level at
Servo ON
1 to
1073741823
0 to
1073741824
1 to
1073741824
1 to
1073741823
2
Excessive Position Error Warning Level at Servo ON
10 to 100 1%
2 Speed Limit Level at Servo ON 0 to 10000 1 min
-1
2
Multiplier per One
Fully-closed Rotation
2 Overload Warning Level
0 to 100
1 to 100
2
Derating of Base Current at Detecting
Overload of Motor
2 Reserved (Do not change.)
10 to 100
–
2 Reserved (Do not change.) −
2 Program JOG Operation Related Switch 0000 to 0005
1%
1%
1%
–
−
−
1 reference unit
1 reference unit
1 reference unit
1 reference unit n.
4th 3rd 2nd 1st digit digit digit digit
Factory
Setting
When
Enabled
Classification
(cont’d)
Reference
Section
5242880 Immediately Setup
7
1073741824
Immediately Setup
Immediately Setup
5242880 Immediately Setup
100 Immediately Setup
10000 Immediately Setup
20
20
100
50
0FFF
0000
Immediately Tuning 8.3.6
Immediately Setup
After restart Setup
– –
− −
Immediately Setup
5.1.4
9.1.1
4.8.6
4.8.7
5.1.4
5.1.4
5.1.4
4.3.8
4.3.8
–
–
6.5
Pn530
Program JOG Operation Switch
0 (Waiting time Pn535 → Forward movement Pn531) × Number of movements Pn536
1
2
(Waiting time Pn535
(Waiting time Pn535
→
→
Reverse movement Pn531)
Forward movement Pn531)
×
×
Number of movements Pn536
Number of movements Pn536
(Waiting time Pn535 → Reverse movement Pn531) × Number of movements Pn536
3 (Waiting time Pn535 → Reverse movement Pn531) × Number of movements Pn536
(Waiting time Pn535 → Forward movement Pn531) × Number of movements Pn536
4 (Waiting time Pn535 → Forward movement Pn531 → Waiting time Pn535
Reverse movement Pn531) × Number of movements Pn536
→
5 (Waiting time Pn535 → Reverse movement Pn531 → Waiting time Pn535
Forward movement Pn531) × Number of movements Pn536
→
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
Pn531
Pn533
Pn534
Pn535
Pn536
4
Program JOG Movement
Distance
2 Program JOG Movement Speed
2
Program JOG Acceleration/Deceleration
Time
2 Program JOG Waiting Time
2
Number of Times of Program JOG Movement
1 to
1073741824
1 reference unit
1 to 10000 1 min
-1
2 to 10000
0 to 1000
1 ms
1 time
32768 Immediately Setup
500
100
100
1
Immediately Setup
Immediately Setup
Immediately Setup
Immediately Setup
6.5
6.5
6.5
6.5
6.5
10
10-23
10 Appendix
10.1.2 Parameters
Parameter
No.
Size
Pn550
Name
2 Analog Monitor 1 Offset Voltage
Pn551
Pn552
Pn553
Pn560
Pn561
Pn600
Pn601
Pn621 to
Pn628
*4
2 Analog Monitor 2 Offset Voltage
2
2
2
Analog Monitor
Magnification ( × 1)
Analog Monitor
Magnification ( × 2)
Remained Vibration
Detection Width
Setting
Range
-10000 to
10000
-10000 to
10000
-10000 to
10000
-10000 to
10000
1 to 3000
Units
0.1 V
0.1 V
× 0.01
× 0.01
Factory
Setting
0
When
Enabled
Classification
Immediately Setup
(cont’d)
Reference
Section
5.1.3
0
100
100
Immediately Setup
Immediately Setup
Immediately Setup
5.1.3
5.1.3
5.1.3
2 Overshoot Detection Level 0 to 100
0.1%
1%
400
100
Immediately Setup
Immediately Setup
5.7.1
5.3.1
5.4.1
2 Regenerative Resistor Capacity
*2
2 Dynamic brake resistor capacity
Depends on
SERVO-
PACK
Capacity
*3
0 or higher
(Max. value depends on model.)
*3
10 W
10 W
0
0
Immediately Setup
Immediately Setup
–
SERVOPACK: Safety Module Parameters
2 Communications Control n.
4th 3rd 2nd 1st digit digit digit digit
–
–
–
–
–
0040
– –
Immediately Setup
MECHATROLINKII Communications Check Mask (for debug)
0
1
2
3
No mask
Ignores MECHATROLINK communications error (A.E6 ).
Ignores WDT error (A.E5 ).
Ignores both MECHATROLINK communications error (A.E6 ) and WDT error (A.E5 ).
3.8.3
3.9.2
–
*1
Pn800
5
6
3
4
7
Warning Check Mask
0 No mask
1
2
Ignores data setting warning (A.94 ).
Ignores command warning (A.95 ).
Ignores both data setting warning (A.94 ) and command warning (A.95 ).
Ignores communications warning (A.96 ).
Ignores both data setting warning (A.94 ) and communications warning (A.96 ).
Ignores both command warning (A.95 ) and communications warning (A.96 ).
Ignores data setting warning (A.94 ), command warning (A.95 ) and communications warning
(A.96 ).
Reserved (Do not change.)
Reserved (Do not change.)
∗1.
For details, refer to Σ -V Series User’s Manual MECHATROLINK-II Commands (No.: SIEP S800000 54).
∗2.
Normally set to "0." When using an external regenerative resistor, set the capacity (W) of the regenerative resistor unit.
∗3.
The upper limit is the maximum output capacity (W) of the SERVOPACK.
∗4.
These parameters can be set in SERVOPACKs with safety modules. For details, refer to
Safety Module (No.: SIEP C720829 06).
Σ -V Series User’s Manual,
10-24
10.1 List of Parameters
Parameter
No.
Size
2
Name
Application Function Select 6
(Software LS) n.
4th digit
3rd digit
2nd digit
1st digit
Pn801
Setting
Range
–
Units
–
Factory
Setting
0003
When
Enabled
Classification
Immediately Setup
(cont’d)
Reference
Section
4.3.3
Software Limit Function
0
1
2
3
Enables forward and reverse software limit.
Disables forward software limit.
Disables reverse software limit.
Disables software limit in both directions.
Reserved (Do not change.)
Software Limit for Reference
0
1
Disables software limit for reference.
Enables software limit for reference.
Pn803
Pn804
Pn806
Pn808
Pn80A
Pn80B
Pn80C
Pn80D
Pn80E
Reserved (Do not change.)
2 Origin Range 0 to 250
1 reference unit
10 Immediately Setup *1
4 Forward Software Limit
4 Reverse Software Limit
4
Absolute Encoder Origin
Offset
-
1073741823 to
1073741823
-
1073741823 to
1073741823
-
1073741823 to
1073741823
1 reference unit
1 reference unit
1 reference unit
1073741823 Immediately Setup
-1073741823 Immediately Setup
0 Immediately
*5 Setup
4.3.3
4.3.3
4.7.8
2
2
2 Acceleration Constant Switching Speed
2
1st Linear Acceleration
Constant
2nd Linear Acceleration
Constant
1st Linear Deceleration
Constant
1 to 65535
1 to 65535
0 to 65535
1 to 65535
10000 reference unit/s
2
10000 reference unit/s
2
100 reference unit/s
10000 reference unit/s
2
100
100
0
100
Immediately
*6
Immediately
*6
Immediately
*6
Immediately
*6
Setup
Setup
Setup
Setup
*1
*1
*1
*1
2
2nd Linear Deceleration
Constant
1 to 65535
10000 reference unit/s
2
100 Immediately
*6 Setup *1
∗1.
For details, refer to Σ -V Series User’s Manual MECHATROLINK-II Commands
∗5.
Available after the SENS_ON command is input.
(No.: SIEP S800000 54).
∗6.
Change the setting when the reference is stopped (DEN is set to 1), because the change will affect the output during operation.
10
10-25
10 Appendix
10.1.2 Parameters
Parameter
No.
Size
Pn80F
Pn810
Pn811
Pn812
Pn814
Name
Setting
Range
Units
2
2
Deceleration Constant Switching Speed
Exponential Function
Acceleration/Deceleration Bias
0 to 65535
0 to 65535
100 reference unit/s
100 reference unit/s
2
Exponential Function
Acceleration/Deceleration Time Constant
2 Movement Average Time
4
2
Final Travel Distance for External Positioning
Homing Mode Setting
0 to 5100 0.1 ms
0 to 5100 0.1 ms
-1073741823 to
1073741823
1 reference unit
– –
Factory
Setting
0
0
0
0
100
0000
When
Enabled
Immediately
*6
Immediately
*7
Immediately
*7
Immediately
*7
Immediately
Immediately
Classification
Setup
Setup
Setup
Setup
Setup
Setup
(cont’d)
Reference
Section
*1
*1
*1
*1
*1
*1 n.
4th digit
3rd digit
2nd digit
1st digit
Pn816
Homing Direction
0
1
Forward
Reverse
Reserved (Do not change.)
Reserved (Do not change.)
Pn817
*8
Pn818
*9
Pn819
Reserved (Do not change.)
2
2
Homing Approach Speed 1
Homing Approach Speed 2
0 to 65535
0 to 65535
100 reference unit/s
100 reference unit/s
50
5
Immediately
*6
Immediately
*6
Setup
Setup
*1
*1
4 Final Travel Distance for Homing
-1073741823 to
1073741823
1 reference unit
100 Immediately Setup *1
∗1.
For details, refer to Σ -V Series User’s Manual MECHATROLINK-II Commands
∗6.
Change the setting when the reference is stopped (DEN is set to 1), because the change will affect the output during
∗8.
The set value of Pn842 is valid when the set value of Pn817 is 0.
∗9.
The set value of Pn844 is valid when the set value of Pn818 is 0.
(No.: SIEP S800000 54).
operation.
∗7.
The settings are updated only if the sending of the reference has been stopped (DEN is set to 1).
10-26
10.1 List of Parameters
Parameter
No.
Size Name
2
Input Signal Monitor
Selection n.
4th 3rd 2nd 1st digit digit digit digit
Pn81E
Setting
Range
–
IO12 Signal Mapping
0 No mapping
Monitors CN1-40 input terminal.
1
2
3
4
5
Monitors CN1-41 input terminal.
Monitors CN1-42 input terminal.
Monitors CN1-43 input terminal.
Monitors CN1-44 input terminal.
6
7
Monitors CN1-45 input terminal.
Monitors CN1-46 input terminal.
Units
–
IO13 Signal Mapping
0 to 7 Same as IO12 signal mapping.
IO14 Signal Mapping
0 to 7 Same as IO12 signal mapping.
IO15 Signal Mapping
0 to 7 Same as IO12 signal mapping.
Factory
Setting
0000
When
Enabled
Immediately
Classification
(cont’d)
Reference
Section
Setup *1
0000 After restart Setup *1 2 Command Data Allocation n.
4th digit
3rd digit
2nd digit
1st digit
–
Option Field Allocation
0
Disables OPTION bit allocation.
1
Enables OPTION bit allocation.
–
Pn81F
Position Control Command TFF/TLIM Function Allocation
0
Disables allocation.
1 Enables allocation.
Reserved (Do not change.)
Pn820
Pn822
Reserved (Do not change.)
4 Forward Latching Allowable Area
-2147483648 to
2147483647
1 reference unit
0 Immediately Setup
4 Reverse Latching Allowable Area
-2147483648 to
2147483647
1 reference unit
0 Immediately Setup
∗1.
For details, refer to Σ -V Series User’s Manual MECHATROLINK-II Commands (No.: SIEP S800000 54).
*1
*1
10
10-27
10 Appendix
10.1.2 Parameters
10-28
Parameter
No.
Pn824
Pn825
Pn827
Pn829
Size
2
2
2
Name
Setting
Range
– Option Monitor 1 Selection
0000H
0001H
Motor rotating speed
[1000000H/overspeed detection position]
Speed reference
[1000000H/overspeed detection position]
0002H Torque [1000000H/max. torque]
0003H Position error (lower 32 bits) [reference unit]
0004H Position error (upper 32 bits) [reference unit]
0005H System reserved
0006H System reserved
000AH Encoder count (lower 32 bits) [reference unit]
000BH Encoder count (upper 32 bits) [reference unit]
000CH FPG count (lower 32 bits) [reference unit]
000DH FPG count (upper 32 bits) [reference unit]
0010H Un000: Motor rotating speed [min
-1
]
Units
–
0011H Un001: Speed reference [min
-1
]
0012H Un002: Torque reference [%]
0013H
Un003: Rotational angle 1 (encoder pulses from the phase-C origin: decimal display)
0014H Un004: Rotational angle 2 [deg]
0015H Un005: Input signal monitor
0016H Un006: Output signal monitor
0017H Un007: Input position reference speed [min
-1
]
0018H Un008: Position error [reference unit]
0019H Un009: Accumulated load ratio [%]
001AH Un00A: Regenerative load ratio [%]
001BH Un00B: DB resistance consumption power [%]
001CH Un00C: Input reference counter [reference unit]
001DH Un00D: Feedback pulse counter [encoder pulse]
001EH
Un00E: Fully-closed loop feedback pulse counter
[external encoder resolution]
001FH System reserved
0023H Primary multi-turn data [Rev]
0024H Primary incremental data [pulse]
0080H
Previous value of latched feedback position (LPOS)
[encoder pulse]
– Option Monitor 2 Selection
0000H to 0080H
–
Same as Option Monitor 1 Selection.
Linear Deceleration Constant 1 for Stopping
1 to 65535
10000 reference unit/s
2
Factory
Setting
0000
0000
100
When
Enabled
Immediately
*6
Classification
Immediately Setup
Immediately Setup
Setup
(cont’d)
Reference
Section
*1
*1
*1
2
SVOFF Waiting Time (SVOFF at deceleration to stop)
0 to 65535 10 ms 0 Immediately
*6 Setup *1
∗1.
For details, refer to operation.
Σ -V Series User’s Manual MECHATROLINK-II Commands (No.: SIEP S800000 54).
∗6.
Change the setting when the reference is stopped (DEN is set to 1), because the change will affect the output during
10.1 List of Parameters
Parameter
No.
Size Name
2 Option Field Allocation 1 n.
4th digit
3rd digit
2nd digit
1st digit
0 to E ACCFIL bit position
Setting
Range
0000 to
1E1E
Pn82A
0
1
Disables ACCFIL bit allocation.
Enables ACCFIL bit allocation.
Units
–
Factory
Setting
1813
When
Enabled
After restart
Classification
(cont’d)
Reference
Section
Setup *1
Pn82B
0 to E
GSEL bit position
2 Option Field Allocation 2
0
1
Disables GSEL bit allocation.
Enables GSEL bit allocation.
0000 to
1F1F n.
4th digit
3rd digit
2nd digit
1st digit
0 to F
V_PPI bit position
0
1
Disables V_PPI bit allocation.
Enables V_PPI bit allocation.
– 1D1C After restart Setup *1
Pn82C
0 to F P_PI_CLR bit position
2 Option Field Allocation 3
0
1
Disables P_PI_CLR bit allocation.
Enables P_PI_CLR bit allocation.
0000 to
1F1F
– n.
4th digit
3rd digit
2nd digit
1st digit
0 to F
P_CL bit position
0
1
Disables P_CL bit allocation.
Enables P_CL bit allocation.
1F1E After restart Setup
0 to F
N_CL bit position
0
1
Disables N_CL bit allocation.
Enables N_CL bit allocation.
∗1.
For details, refer to Σ -V Series User’s Manual MECHATROLINK-II Commands (No.: SIEP S800000 54).
*1
10
10-29
10 Appendix
10.1.2 Parameters
Parameter
No.
Size Name
2 Option Field Allocation 4 n.
4th digit
3rd digit
2nd digit
1st digit
Setting
Range
0000 to
1F1C
0 to C BANK_SEL1 bit position
Pn82D
0
1
Disables BANK_SEL1 bit allocation.
Enables BANK_SEL1 bit allocation.
Units
–
Factory
Setting
0000
When
Enabled
After restart
Classification
(cont’d)
Reference
Section
Setup *1
0 to F
LT_DISABLE bit position
2 Option Field Allocation 5
0
1
Disables LT_DISABLE bit allocation.
Enables LT_DISABLE bit allocation.
0000 to
1D1F
– n.
4th digit
3rd digit
2nd digit
1st digit
Reserved (Do not change.)
0000 After restart Setup *1
Pn82E
Pn833
Reserved (Do not change.)
2 Motion Setting n.
4th digit
3rd digit
2nd digit
1st digit
0 to D OUT_SIGNAL bit position
0
1
Disables OUT_SIGNAL bit allocation.
Enables OUT_SIGNAL bit allocation.
0000 to 0001 – 0000 After restart Setup
Linear Accel/Decel Constant Selection
0
1
Uses Pn80A to Pn80F and Pn827. (Setting of Pn834 to Pn840 disabled)
Uses Pn834 to Pn840. (Setting of Pn80A to Pn80F and Pn827 disabled)
*1
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
∗1.
For details, refer to Σ -V Series User’s Manual MECHATROLINK-II Commands (No.: SIEP S800000 54).
10-30
10.1 List of Parameters
Parameter
No.
Pn834
Pn836
Pn838
Pn83A
Pn83C
Pn83E
Pn840
Pn842
*8
Pn844
*9
Pn850
Pn851
Size Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
(cont’d)
Reference
Section
4
4
1st Linear Acceleration
Constant 2
2nd Linear Acceleration
Constant 2
4 Acceleration Constant Switching Speed 2
4
4
1st Linear Deceleration
Constant 2
2nd Linear Deceleration
Constant 2
4 Deceleration Constant Switching Speed 2
4
Linear Deceleration
Constant 2 for Stopping
4 Homing Approach Speed 12
4 Homing Approach Speed 22
1 to
20971520
1 to
20971520
0 to
2097152000
1 to
20971520
1 to
20971520
0 to
2097152000
1 to
20971520
0 to
20971520
0 to
20971520
1 reference unit/s
10000 reference unit/s
2
100 reference unit/s
100 reference unit/s
10000 reference unit/s
2
10000 reference unit/s
1 reference unit/s
10000 reference unit/s
2
10000 reference unit/s
2
–
100
100
0
100
100
0
100
0
0
Immediately
*6
Immediately
*6
Immediately
*6
Immediately
*6
Immediately
*6
Immediately
*6
Immediately
*6
Immediately
*6
Immediately
*6
Setup
Setup
Setup
Setup
Setup
Setup
Setup
Setup
Setup
*1
*1
*1
*1
*1
*1
*1
*1
*1
2 Latch Sequence Number 0 to 8 0 Immediately Setup *1
2 Continuous Latch Count 0 to 255 – 0 Immediately Setup *1
∗1.
For details, refer to Σ -V Series User’s Manual MECHATROLINK-II Commands operation.
∗8.
The set value of Pn842 is valid when the set value of Pn817 is 0.
∗9.
The set value of Pn844 is valid when the set value of Pn818 is 0.
(No.: SIEP S800000 54).
∗6.
Change the setting when the reference is stopped (DEN is set to 1), because the change will affect the output during
10
10-31
10 Appendix
10.1.2 Parameters
10-32
Parameter
No.
Size Name
2 Latch Sequence Signal 1 to 4 Setting n.
4th digit
3rd digit
2nd digit
1st digit
Latch sequence 1 signal selection.
0
Phase C
1
2
3
EXT1 signal
EXT2 signal
EXT3 signal
Pn852
Setting
Range
0000 to 3333
Units
–
Factory
Setting
0000
When
Enabled
Classification
Immediately Setup
(cont’d)
Reference
Section
*1
Latch sequence 2 signal selection.
0 to 3
Same as latch sequence 1 signal selection.
Latch sequence 3 signal selection.
0 to 3
Same as latch sequence 1 signal selection.
Latch sequence 4 signal selection.
0 to 3
Same as latch sequence 1 signal selection.
0000 to 3333 – 2 Latch Sequence Signal 5 to 8 Setting n.
4th digit
3rd digit
2nd digit
1st digit
Latch sequence 5 signal selection
0
1
2
3
Phase C
EXT1 signal
EXT2 signal
EXT3 signal
0000 Immediately Setup *1
Pn853
Latch sequence 6 signal selection.
0 to 3
Same as latch sequence 5 signal selection.
Pn880
Pn881
Pn882
Latch sequence 7 signal selection.
0 to 3
Same as latch sequence 5 signal selection.
Latch sequence 8 signal selection.
0 to 3 Same as latch sequence 5 signal selection.
2
2
Station Address Monitor
(for maintenance, read only)
Setting Transmission Byte Monitor [byte]
(for maintenance, read only)
40 to 5FH
17, 32
–
–
0
0
Immediately Setup
Immediately Setup
2
Transmission Cycle Setting Monitor [0.25
μ s]
(for maintenance, read only)
0 to FFFFH – 0 Immediately Setup
∗1.
For details, refer to Σ -V Series User’s Manual MECHATROLINK-II Commands (No.: SIEP S800000 54).
–
–
–
10.1 List of Parameters
Parameter
No.
Size
Pn883
Pn88A
Pn890 to
Pn89E
Pn8A0 to
Pn8AE
Pn900
Name
2
2
4
4
Communications Cycle Setting Monitor
[x transmission cycle]
(for maintenance, read only)
MECHATROLINK Receive Error
Counter Monitor (for maintenance, read only)
Command Data Monitor at Alarm/Warning Occurs
(for maintenance, read only)
Response Data Monitor at Alarm/Warning Occurs
(for maintenance, read only)
2 Parameter Bank Number
Pn901
Pn902 to
Pn910
Pn920 to
Pn95F
2 Parameter Bank Member Number
Setting
Range
0 to 32
0 to 65535
0 to
FFFFFFFFH
0 to
FFFFFFFFH
0 to 16
0 to 15
Units
–
–
–
–
–
–
Factory
Setting
0
0
0
0
0
0
When
Enabled
Classification
(cont’d)
Reference
Section
Immediately Setup
Immediately Setup
Immediately Setup
Immediately Setup
After restart Setup
After restart Setup
2 Parameter Bank Member Definition
0000H to
08FFH
– 0 After restart Setup
2
Parameter Bank Data (nonvolatile memory save disabled)
0000H to
FFFFH
– 0 Immediately Setup
∗1.
For details, refer to Σ -V Series User’s Manual MECHATROLINK-II Commands (No.: SIEP S800000 54).
–
–
*1
*1
*1
*1
*1
*1
10
10-33
10 Appendix
10.2
List of Monitor Displays
The following list shows the available monitor displays.
10-34
∗1.
For details, refer to 7.3 Monitoring Input Signals .
∗2.
For details, refer to 7.4 Monitoring Output Signals .
∗3.
For details, refer to 4.4.3 Electronic Gear .
∗4.
For details, refer to 8.3.3 Setting Encoder Output Pulses (PAO, PBO, and PCO) .
10.3 Parameter Recording Table
10.3
Parameter Recording Table
Use the following table for recording parameters.
Pn125
Pn131
Pn132
Pn135
Pn136
Pn139
Pn081
Pn100
Pn101
Pn102
Pn103
Pn104
Pn105
Pn106
Pn109
Pn10A
Pn10B
Pn10C
Pn10D
Pn10E
Pn10F
Pn11F
Pn121
Pn122
Pn123
Pn124
Parameter
Pn000
Pn001
Pn002
Pn006
Pn007
Pn008
Pn009
Pn00B
Pn00C
Pn00D
0
100
100
0
200
0
0
0
Factory
Setting
0000
0000
0000
0002
0000
4000
0010
0000
0000
0000
0000
400
2000
400
100
400
2000
400
0
0
0000
0
100
Name
When
Enabled
After restart Basic Function Select Switch 0
Application Function Select Switch 1 After restart
Application Function Select Switch 2 After restart
Application Function Select Switch 6 Immediately
Application Function Select Switch 7 Immediately
Application Function Select Switch 8 After restart
Application Function Select Switch 9 After restart
Application Function Select Switch B After restart
Application Function Select Switch C After restart
Application Function Select Switch D After restart
Application Function Select Switch
81
After restart
Speed Loop Gain Immediately
Speed Loop Integral Time Constant Immediately
Position Loop Gain
Moment of Inertia Ratio
Immediately
Immediately
Immediately 2nd Speed Loop Gain
2nd Speed Loop Integral Time Constant
2nd Position Loop Gain
Feedforward Gain
Immediately
Immediately
Immediately
Immediately Feedforward Filter Time Constant
Application Function for Gain Select
Switch
∗1
Mode Switch (torque reference)
Mode Switch (speed reference)
Mode Switch (acceleration)
Mode Switch (position error)
Friction Compensation Frequency
Correction
Friction Compensation Gain Correction
Immediately
Immediately
Immediately
Immediately
Position Integral Time Constant
Friction Compensation Gain
Immediately
Immediately
2nd Gain for Friction Compensation Immediately
Friction Compensation Coefficient Immediately
Immediately
Immediately
0
0
0
0
Gain Switching Time 1
Gain Switching Time 2
Gain Switching Waiting Time 1
Gain Switching Waiting Time 2
Immediately
Immediately
Immediately
Immediately
0000
Automatic Gain Changeover Related
Switch 1
Immediately
∗1.
The timing varies in accordance with the digit changed in a parameter (1st digit, 2nd digit, and so on). For details, refer to 10.1.2 Parameters .
10
10-35
10 Appendix
10-36
Pn165
Pn170
Pn205
Pn207
Pn20A
Pn20E
Pn210
Pn212
Pn22A
Pn230
Pn231
Pn233
Pn281
Pn304
Pn305
Pn144
Pn145
Pn146
Pn147
Pn148
Pn149
Pn14A
Pn14B
Pn14F
Pn160
Pn161
Pn162
Pn163
Pn164
Parameter
Pn13D
Pn140
Pn141
Pn142
Pn143
Factory
Setting
2000
0100
500
1000
1000
1000
500
700
1000
500
1000
800
100
0011
0010
Name
(cont’d)
When
Enabled
Immediately Current Gain Level
Model Following Control Related
Switch
Model Following Control Gain
Immediately
Immediately
Model Following Control Gain Compensation
Model Following Control Bias
(Forward Direction)
Immediately
Immediately
Model Following Control Bias
(Reverse Direction)
Immediately
Vibration Suppression 1 Frequency A Immediately
Vibration Suppression 1 Frequency B Immediately
Model Following Control Speed
Feedforward Compensation
Immediately
Immediately 2nd Model Following Control Gain
2nd Model Following Control Gain
Compensation
Immediately
Immediately Vibration Suppression 2 Frequency
Vibration Suppression 2 Compensation
Control Related Switch
Anti-Resonance Control Related
Switch
Immediately
After restart
Immediately
1000
100
0
0
0
1401
65535
0010
32768
4
1
2048
Anti-Resonance Frequency Immediately
Anti-Resonance Gain Compensation Immediately
Immediately Anti-Resonance Damping Gain
Anti-Resonance Filter Time Constant 1 Compensation
Immediately
Anti-Resonance Filter Time Constant 2 Compensation
Tuning-less Function Related Switch
Multiturn Limit Setting
Position Control Function Switch
Number of External Scale Pitch
Electronic Gear Ratio (Numerator)
Immediately
∗1
After restart
After restart
After restart
After restart
Electronic Gear Ratio (Denominator) After restart
Encoder Output Pulses After restart
0000
0000
0
0
20
500
Fully-closed Control Selection
Switch
Position Control Expanded Function
Switch
Backlash Compensation Value
Backlash Compensation Time Constant
Encoder Output Resolution
JOG Speed
After restart
After reset
Immediately
Immediately
After restart
Immediately
0 Soft Start Acceleration Time Immediately
∗1.
The timing varies in accordance with the digit changed in a parameter (1st digit, 2nd digit, and so on). For details, refer to 10.1.2 Parameters .
10.3 Parameter Recording Table
Pn410
Pn412
Pn415
Pn423
Pn424
Pn425
Pn456
Pn460
Pn501
Pn502
Pn503
Pn401
Pn402
Pn403
Pn404
Pn405
Pn406
Pn407
Pn408
Pn409
Pn40A
Pn40B
Pn40C
Pn40D
Pn40E
Pn40F
Parameter
Pn306
Pn310
Pn311
Pn312
Pn324
Pn506
Pn507
Pn508
Pn509
Pn50A
5000
70
0
5000
70
0
800
800
100
100
800
10000
0000
Factory
Setting
0
0000
100
50
300
100
5000
50
100
0
0000
50
100
15
0101
10
20
10
Name
(cont’d)
When
Enabled
Immediately Soft Start Deceleration Time
Vibration Detection Switch
Vibration Detection Sensibility
Immediately
Immediately
Immediately Vibration Detection Level
Moment of Inertia Calculating Start
Level
Torque Reference Filter Time Constant
Forward Torque Limit
Immediately
Immediately
Reverse Torque Limit
Forward External Torque Limit
Reverse External Torque Limit
Emergency Stop Torque
Immediately
Immediately
Immediately
Immediately
Immediately
Speed Limit during Torque Control
Torque Related Function Switch
Immediately
∗1
1st Notch Filter Frequency Immediately
1st Notch Filter Q Value Immediately
1st Notch Filter Depth
2nd Notch Filter Frequency
2nd Notch Filter Q Value
2nd Notch Filter Depth
Immediately
Immediately
Immediately
Immediately
2nd Step 2nd Torque Reference Filter
Frequency
2nd Step 2nd Torque Reference Filter
Q Value
1st Step 2nd Torque Reference Filter
Time Constant
Reserved
Rotation Detection Level
Speed Coincidence Signal Output
Width
Immediately
Immediately
Immediately
Reserved
Torque Limit at Main Circuit Voltage
Drop
Notch Filter Adjustment Switch
Zero Clamp Level
−
−
Immediately
Release Time for Torque Limit at
Main Circuit Voltage Drop
Immediately
Sweep Torque Reference Amplitude Immediately
Immediately
Immediately
Immediately
Immediately
0
100
50
Brake Reference - Servo OFF Delay
Time
Immediately
Brake Reference Output Speed Level Immediately
Waiting Time for Brake Signal When
Motor Running
Immediately
20
2881
Instantaneous Power Cut Hold Time
Input Signal Selection 1
Immediately
After restart
∗1.
The timing varies in accordance with the digit changed in a parameter (1st digit, 2nd digit, and so on). For details, refer to 10.1.2 Parameters .
10
10-37
10 Appendix
10-38
Pn51E
Pn520
Pn522
Pn524
Pn526
Pn530
Pn531
Pn533
Pn534
Pn535
Pn536
Pn550
Pn551
Pn552
Pn553
Pn560
Pn561
Pn600
Pn601
Pn800
Pn528
Pn529
Pn52A
Pn52B
Pn52C
Pn52D
Pn52F
Pn801
Pn803
Parameter
Pn50B
Pn50E
Pn50F
Pn510
Pn511
Pn512
Pn517
Pn51B
100
5242880
7
1073741824
5242880
0000
32768
500
100
100
1
0
0
100
100
400
100
0
0
0040
100
10000
20
20
100
50
0FFF
0003
10
Factory
Setting
8883
0000
0100
0000
6541
0000
0000
1000
Name
Input Signal Selection 2
Output Signal Selection 1
Output Signal Selection 2
Output Signal Selection 3
Input Signal Selection 5
Output Signal Inverse Setting
Reserved
Excessive Error Level Between Servomotor and Load Positions
Excessive Position Error Warning
Level
Excessive Position Error Alarm
Level
Positioning Completed Width
NEAR Signal Width
Excessive Position Error Alarm
Level at Servo ON
Excessive Position Error Warning
Level at Servo ON
Speed Limit Level at Servo ON
(cont’d)
When
Enabled
After restart
After restart
After restart
After restart
After restart
After restart
–
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Multiplier per One Fully-closed
Rotation
Overload Warning Level
Derating of Base Current at Detecting
Overload of Motor
Reserved
Reserved
Program JOG Operation Related
Switch
Program JOG Movement Distance
Program JOG Movement Speed
Immediately
Immediately
After restart
–
–
Immediately
Immediately
Immediately
Program JOG Acceleration/Deceleration Time
Program JOG Waiting Time
Number of Times of Program JOG
Movement
Analog Monitor 1 Offset Voltage
Immediately
Immediately
Immediately
Immediately
Analog Monitor 2 Offset Voltage Immediately
Analog Monitor Magnification ( × 1) Immediately
Analog Monitor Magnification ( × 2) Immediately
Remained Vibration Detection Width Immediately
Overshoot Detection Level
Regenerative Resistor Capacity
Dynamic Brake Resistor Capacity
Communications Control
Application Function Select 6
(Software LS)
Origin Range
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
10.3 Parameter Recording Table
Pn819
Pn81E
Pn81F
Pn820
Pn822
Pn824
Pn825
Pn827
Pn829
Pn82A
Pn82B
Pn82C
Pn82D
Pn82E
Pn833
Pn834
Parameter
Pn804
Pn806
Pn808
Pn80A
Pn80B
Pn80C
Pn80D
Pn80E
Pn80F
Pn810
Pn811
Pn812
Pn814
Pn816
Pn817
Pn818
Factory
Setting
1073741823
-1073741823
0
100
100
0
100
100
0
0
0
0
100
0000
50
5
100
0000
0000
0
0
0000
0000
100
0
Name
(cont’d)
When
Enabled
Immediately Forward Software Limit
Reverse Software Limit
Absolute Encoder Origin Offset
1st Linear Acceleration Constant
2nd Linear Acceleration Constant
Acceleration Constant Switching
Speed
1st Linear Deceleration Constant
2nd Linear Deceleration Constant
Deceleration Constant Switching
Speed
Exponential Function Acceleration/
Deceleration Bias
Exponential Function Acceleration/
Deceleration Time Constant
Movement Average Time
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Final Travel Distance for External
Positioning
Homing Mode Setting
Homing Approach Speed 1
Homing Approach Speed 2
Final Travel Distance for Homing
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
After restart
Input Signal Monitor Selection
Command Data Allocation
Forward Latching Allowable Area
Reverse Latching Allowable Area
Immediately
Immediately
Option Monitor 1 Selection Immediately
Option Monitor 2 Selection Immediately
Linear Deceleration Constant 1 for
Stopping
SVOFF Waiting Time (SVOFF at deceleration to stop)
Immediately
∗ 3
Immediately
Immediately
Immediately
∗ 2
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
1813
1D1C
1F1E
0000
Option Field Allocation 1
Option Field Allocation 2
Option Field Allocation 3
Option Field Allocation 4
After restart
After restart
After restart
After restart
0000
0000
Option Field Allocation 5
Motion Setting
After restart
After restart
100 1st Linear Acceleration Constant 2
Immediately
∗ 3
∗2.
Available after the SENS_ON command is input.
∗3.
Change the setting when the reference is stopped (DEN is set to 1), because the change will affect the output during operation.
10
10-39
10 Appendix
Parameter
Pn836
Pn838
Pn83A
Pn83C
Pn83E
Pn840
Pn842
Pn844
Pn850
Pn851
Pn852
Pn853
Pn880
Pn881
Pn882
Pn883
Pn88A
Pn890 to
Pn89E
Pn8A0 to
Pn8AE
Pn900
Pn901
Pn902 to
Pn910
Pn920 to
Pn95F
Factory
Setting
100
0
100
100
0
100
0
0
0
0
0000
0000
0
0
0
0
0
0
0
0
0
Name
2nd Linear Acceleration Constant 2
(cont’d)
When
Enabled
Immediately
∗ 3
Immediately
∗ 3
Acceleration Constant Switching
Speed 2
1st Linear Deceleration Constant 2
2nd Linear Deceleration Constant 2
Deceleration Constant Switching
Speed 2
Linear Deceleration Constant 2 for
Stopping
Homing Approach Speed 12
Homing Approach Speed 22
Latch Sequence Number
Continuous Latch Count
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
∗ 3
Immediately
Immediately
Latch Sequence Signal 1 to 4 Setting Immediately
Latch Sequence Signal 5 to 8 Setting Immediately
Station Address Monitor
(for maintenance, read only)
Setting Transmission Byte Monitor
[byte] (for maintenance, read only)
Transmission Cycle Setting Monitor
[0.25 μ s]
(for maintenance, read only)
Communications Cycle Setting
Monitor [x transmission cycle]
(for maintenance, read only)
MECHATROLINK Receive Error
Counter Monitor
(for maintenance, read only)
Command Data Monitor at Alarm/
Warning Occurs
(for maintenance, read only)
Response Data Monitor at Alarm/
Warning Occurs
(for maintenance, read only)
Parameter Bank Number
Parameter Bank Member Number
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
After restart
After restart
0 Parameter Bank Member Definition After restart
0
Parameter Bank Data (nonvolatile memory save disabled)
Immediately
∗3.
Change the setting when the reference is stopped (DEN is set to 1), because the change will affect the output during operation.
10-40
Index
Index
Symbols
/BK - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-13
/CLT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-37
/COIN - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-56
/HWBB1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-64
/HWBB2 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-64
/N-CL - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-36
/NEAR- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-57
/P-CL- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-36
/S-RDY - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-54
/TGON - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-54
/V-CMP - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-55
/VLT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-58
/WARN - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-53
A absolute data reception sequence - - - - - - - - - - - - - - - - - - - - - - 4-46 absolute data request (SENS_ON) - - - - - - - - - - - - - - - - - - - - - 4-41 absolute encoder battery alarm (A.830) - - - - - - - - - - - - - - - - - - 4-42 absolute encoder origin offset - - - - - - - - - - - - - - - - - - - - - - - - 4-52 absolute encoders - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-38 connection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-39 set up and initialization- - - - - - - - - - - - - - - - - - - - - - - - - - 4-44
AC reactor - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-50 additional adjustment function - - - - - - - - - - - - - - - - - - - - - - - - 5-57 advanced autotuning (Fn201)- - - - - - - - - - - - - - - - - - - - - - - - - 5-18 anti-resonance control adjustment function - - - - - - - - - - - - 5-25 calculating moment of inertia - - - - - - - - - - - - - - - - - - - - - 5-21 feedforward - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-26 friction compensation- - - - - - - - - - - - - - - - - - - - - - - - - - - 5-26 mode selection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-21 notch filter - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-25
STROKE (travel distance) setting - - - - - - - - - - - - - - - - - - 5-22 type selection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-21 vibration suppression - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-25 advanced autotuning by reference (Fn202)- - - - - - - - - - - - - - - - 5-28 anti-resonance control adjustment function - - - - - - - - - - - - 5-32 feedforward - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-33 friction compensation- - - - - - - - - - - - - - - - - - - - - - - - - - - 5-33 mode selection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-30 notch filter - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-32 type selection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-30 vibration suppression - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-32 alarm history display (Fn000) - - - - - - - - - - - - - - - - - - - - - - - - - 6-3 alarm reset - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-2 alarm reset method- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-53
ALM - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-53 ambient/storage humidity - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-7 anti-resonance control adjustment function (Fn204) - - - - - - - - - 5-45 application example of safety functions- - - - - - - - - - - - - - - - - - 4-68 automatic gain switching - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-58 automatic offset-signal adjustment of the motor current detection signal (Fn00E) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-18 automatically setting the notch filter - - - - - - - - - - - - - - - - - - - - 5-12
B backlash compensation function - - - - - - - - - - - - - - - - - - - - - - 5-64 baseblock- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-2 battery battery case - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-38 battery replacement - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-42 installing the battery in the host controller- - - - - - - - - - - - - 4-40 using an encoder cable with a battery case- - - - - - - - - 4-39 , 4-43 baud rate - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-9
BB - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - iii , 4-34 brake operation delay time - - - - - - - - - - - - - - - - - - - - - - - - - - 4-12 brake signals - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-13
C
CCW- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-5 , 8-15
CE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - xvi changing detection timing of overload (low load) alarm
(A.720) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-23 changing detection timing of overload warning (A.910) - - - - - - 4-22 checking output torque limiting during operation - - - - - - - - - - - 4-37 clearing alarm history (Fn006) - - - - - - - - - - - - - - - - - - - - - - - 6-13
CN1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-23
CN2 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-34
CN3 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-2
CN6A - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-33
CN6B - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-33
CN7 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-2
CN8 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-24 coast to a stop - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-7 communication protocol- - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-9 compatible adjustment function - - - - - - - - - - - - - - - - - - - - - - - 5-71 confirming safety functions- - - - - - - - - - - - - - - - - - - - - - - - - - 4-69 connecting a reactor for harmonic suppression - - - - - - - - - - - - - 3-50 connecting a safety function device - - - - - - - - - - - - - - - - - - - - 4-69 connection example of EDM1 output signal - - - - - - - - - - - - - - 4-67 connection example of HWBB input signals - - - - - - - - - - - - - - 4-64 connection to host controller (interface) sequence input circuit - - - - - - - - - - - - - - - - - - - - - - - - - - 3-29 sequence output circuit- - - - - - - - - - - - - - - - - - - - - - - - - - 3-31 connector CN5 for analog monitor - - - - - - - - - - - - - - - - - - - - - - 5-5 current control mode selection- - - - - - - - - - - - - - - - - - - - - - - - 5-63 current gain level setting - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-63
CW - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-5 , 8-15
D
DC reactor - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-50 decelerate to stop - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-7 digital operator displays during testing without motor - - - - - - - - 4-34
DIP switch - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-2 setting - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-3 display of servomotor ID in feedback option module (Fn01F) - - 6-30 display of SERVOPACK and servomotor ID (Fn01E) - - - - - - - - 6-28 dynamic brake answer function - - - - - - - - - - - - - - - - - - - - - - - 3-42 dynamic brake unit - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-40
Index-1
Index
E
EasyFFT (Fn206) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-33
EDM1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-66 electronic gear - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-26 electronic gear ratio - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-27 encoder output pulse setting- - - - - - - - - - - - - - - - - - - - - - - - - - 4-30 encoder output pulses - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-29 encoder signal (CN2) names and functions- - - - - - - - - - - - - - - - 3-34 error detection in HWBB signal - - - - - - - - - - - - - - - - - - - - - - - 4-63 european directives- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - xvi examples of encoder connection - - - - - - - - - - - - - - - - - - - - - - - 3-34 external device monitor- - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-66 external latch signal 1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-27 external latch signal 2 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-27 external latch signal 3 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-27 external torque limit - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-36
F feedforward- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-71 feedforward compensation- - - - - - - - - - - - - - - - - - - - - - - - - - - 5-71
FG - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-24 , 3-25 forward external torque limit - - - - - - - - - - - - - - - - - - - - - - - - - 4-36 friction compensation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-61 fully-closed loop control alarm detection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-22 analog monitor signal - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-23 analog signal input timing - - - - - - - - - - - - - - - - - - - - - - - - - 8-5 connection example of external encoder by Heidenhain - - - - - 8-6 connection example of external encoder by Magnescale
Co., Ltd. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-6 connection example of external encoder by Mitutoyo
Corporation- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-6 connection example of external encoder by Renishaw plc- - - - 8-6 electronic gear - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-21 external absolute encoder data reception sequence- - - - - - - - 8-18 internal block diagram - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-3 motor rotation direction- - - - - - - - - - - - - - - - - - - - - - - - - - 8-15 serial converter unit - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-4 setting encoder output pulses - - - - - - - - - - - - - - - - - - - - - - 8-17 sine wave pitch (frequency) for an external encoder- - - - - - - 8-17 speed feedback method - - - - - - - - - - - - - - - - - - - - - - - - - - 8-23 system configuration- - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-2
G gain adjustment of analog monitor output (Fn00D) - - - - - - - - - - 6-16
Gr.1 alarm- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-16
Gr.2 alarm- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-16 grounding - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-47
G-SEL of OPTION field - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-58
H hard wire base block (HWBB) function - - - - - - - - - - - - - - - - - - 4-60 hard wire base block (HWBB) state - - - - - - - - - - - - - - - - - - - - 4-61 harmonized standards - - - - - - - - - - - - - - - - - - - - - - - - - - - -xvi , 1-7 holding brakes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-11 homing deceleration switch signal - - - - - - - - - - - - - - - - - - - - - 3-27
I initial incremental pulses - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-47 initializing parameter settings (Fn005)- - - - - - - - - - - - - - - - - - - 6-12 input signal (CN1) allocations- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-26 monitoring - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-4 names and functions - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-23 instantaneous power interruption settings - - - - - - - - - - - - - - - - - 4-18
Index-2
internal block diagrams- - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-10 internal torque limit - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-35
J
JOG operation (Fn002) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-4
L
LED (COM) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-2 , 1-8
LED (POWER) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-2 , 1-8 limit switches - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-6 limiting torque - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-35 list of alarms - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-2 list of monitor displays - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-2 list of warnings - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-22
M main circuit names and functions of terminals - - - - - - - - - - - - - - - - - - - - 3-3 wires - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-5 wiring examples - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-14 manual gain switching - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-58 manual offset-signal adjustment of the motor current detection signal (Fn00F)- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-19
MECHATROLINK-II communications connector- - - - - - - - 1-2 , 3-33
MECHATROLINK-II function specifications - - - - - - - - - - - - - - 1-9 monitor displays (Un ) - - - - - - - - - - - - - - - - - - - - - 2-8 , 10-34 monitor factor - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-7 monitoring safety input signals - - - - - - - - - - - - - - - - - - - - - - - - 7-7 multiturn limit disagreement alarm (A.CC0) - - - - - - - - - - - - - - 4-51 multiturn limit setting- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-50
N noise filter - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-47
N-OT- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-6 notch filter - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-76
O offset adjustment of analog monitor output (Fn00C) - - - - - - - - - 6-14 one-parameter tuning (Fn203) - - - - - - - - - - - - - - - - - - - - - - - - 5-35 anti-resonance control adjustment function - - - - - - - - - - - - 5-41 feedforward - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-42 friction compensation - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-42 notch filter - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-41 tuning mode - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-36 , 5-39 type selection - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-37 , 5-39 one-parameter tuning example - - - - - - - - - - - - - - - - - - - - - - - - 5-43 online vibration monitor (Fn207) - - - - - - - - - - - - - - - - - - - - - - 6-37 origin search (Fn003) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-6 origin setting (Fn020)- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-31 output phase form - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-29 output signal (CN1) allocations - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-27 monitoring - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-6 names and functions- - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-23 overtravel (OT) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-6 overtravel warning function- - - - - - - - - - - - - - - - - - - - - - - - - - - 4-8
Index
P panel display- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-2
PAO - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-29 parameter classification- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-5 how to make numeric settings using parameters - - - - - - - - - - 2-6 how to select functions using parameters - - - - - - - - - - - - - - - 2-7 parameters for numeric settings - - - - - - - - - - - - - - - - - - -iv , 2-5 parameters for selecting functions - - - - - - - - - - - - - - - - -iv , 2-5 tuning parameters - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-5 parameter recording table - - - - - - - - - - - - - - - - - - - - - - - - - - 10-35 parameters - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-3
PBO - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-29
PCO - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-29 position integral- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-70 positioning completed signal - - - - - - - - - - - - - - - - - - - - - - - - - 4-56 positioning near signal - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-57
P-OT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-6 precautions for safety functions - - - - - - - - - - - - - - - - - - - - - - - 4-70 precautions for wiring - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-18 precautions on connecting noise filter - - - - - - - - - - - - - - - - - - - 3-48 program JOG operation (Fn004) - - - - - - - - - - - - - - - - - - - - - - - 6-8 protection class/pollution degree - - - - - - - - - - - - - - - - - - - - - - - 1-7
R reference unit - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-26 regenerative resistor unit- - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-36 resetting configuration errors in option modules (Fn014) - - - - - - 6-25 resetting the HWBB state - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-62 reverse external torque limit - - - - - - - - - - - - - - - - - - - - - - - - - 4-36 risk assessment - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-60 rotary switch - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-2 , 4-4 rotation detection output signal - - - - - - - - - - - - - - - - - - - - - - - 4-54 rotational serial data - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-47 , 4-48
RUN - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-34
S safety function - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-60 safety function signal (CN8) names and functions- - - - - - - - - - - 3-24 safety precautions on adjustment of servo gains - - - - - - - - - - - - - 5-8
SEMI F47 function - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-19 servo alarm output signal - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-53 servo gains - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-3 servo ready output signal - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-54 servomotor model display (Fn011) - - - - - - - - - - - - - - - - - - - - - 6-23 servomotor rotation direction- - - - - - - - - - - - - - - - - - - - - - - - - - 4-5
SERVOPACK basic specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-7 inspection and maintenance- - - - - - - - - - - - - - - - - - - - - - - 1-16
MECHATROLINK-II function specifications - - - - - - - - - - - 1-9 model designation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-13 part names - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-2 ratings - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-6 status display - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-2 setting encoder output pulse - - - - - - - - - - - - - - - - - - - - - - - - - 4-30 setting motor overload detection level - - - - - - - - - - - - - - - - - - - 4-22 setting regenerative resistor capacity- - - - - - - - - - - - - - - - - - - - 3-38 soft start time setting - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-7 software limit settings - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-10 software reset (Fn030) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-32 software version display (Fn012) - - - - - - - - - - - - - - - - - - - - - - 6-24 specifications of EDM1 output signal - - - - - - - - - - - - - - - - - - - 4-67 specifications of HWBB signals- - - - - - - - - - - - - - - - - - - - - - - 4-64 speed coincidence signal- - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-55 speed control range - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-7 speed detection method selection - - - - - - - - - - - - - - - - - - - - - - 5-63 speed regulation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-7 standard power supply input main circuit wires for SERVOPACKs and converters - - - - - - 3-5 molded-case circuit breaker - - - - - - - - - - - - - - - - - - - - - - 3-19 power supply capacities and power losses - - - - - - - - - - - - - 3-19 wiring examples - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-14 station address - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-9 stopping method for servomotor after SV_OFF command is received- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-16 stopping method for servomotor when an alarm occurs - - - - 4-16 , 9-2 storage temperature - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-7 surrounding air temperature - - - - - - - - - - - - - - - - - - - - - - - - - - 1-7
SW1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-2 , 4-4
SW2 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-2 , 4-3 switching condition A - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-58 switching gain settings - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-57
T terminator - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-33 test without motor function - - - - - - - - - - - - - - - - - - - - - - - - - - 4-31 time stamps - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-3 torque control tolerance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-7 torque limit function for low DC power supply voltage for main circuit - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-19 torque reference filter- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-74 transmission cycle - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-9 trial operation inspection and checking before trial operation - - - - - - - - - - 4-24 trial operation via MECHATROLINK-II- - - - - - - - - - - - - - 4-25 troubleshooting alarms - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-6 warnings - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-23 troubleshooting malfunction based on operation and conditions of the servomotor - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-28 tuning parameters - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-5 tuning-less function - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-11 tuning-less level settings (Fn200)- - - - - - - - - - - - - - - - - - - - - - 5-12
U
UL - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - xvi using the mode switch (P/PI switching) - - - - - - - - - - - - - - - - - 5-72 utility functions (Fn )- - - - - - - - - - - - - - - - - - - - - - - 2-4 , 10-2
V vibration detection level initialization (Fn01B) - - - - - - - - - - - - 6-26 vibration suppression function (Fn205)- - - - - - - - - - - - - - - - - - 5-52 vibration/shock resistance- - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-7
W warning output signal- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-53 wiring for noise control - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-46 wiring MECHATROLINK-II communications- - - - - - - - - - - - - 3-33 write prohibited setting (Fn010)- - - - - - - - - - - - - - - - - - - - - - - 6-21
Z zero clamp mode- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-7
Index-3
Revision History
The revision dates and numbers of the revised manuals are given on the bottom of the back cover.
MANUAL NO.
SIEP S800000 90B
Published in Japan March 2013 12-8 1
Date of publication
Revision number
Date of original publication
M-II
Date of
Publication
September 2014
August 2013
March 2013
Rev.
No.
3
2
Section
8.1.3 (2)
8.1.4, 8.3.5
10.3
Preface, 1.4.2
1
Back cover
All chapters
August 2012 – –
Revised Content
Revision: Description of analog signal input timing
Addition: External encoder by Heidenhain (models: LIC4100-series models)
Revision: Name and enable timing of Pn601
Revision: Description of Harmonized Standards
EN 55011 /A2 changed to EN 55011
Revision: Address
Addition: Descriptions related to SGDV H SERVOPACKs.
Revision: Slightly revised.
First edition
AC Servo Drives
Σ
-
V
Series
USER’S MANUAL
For Use with Large-Capacity Models
Design and Maintenance
Rotational Motor
MECHATROLINK-
II
Communications Reference
IRUMA BUSINESS CENTER (SOLUTION CENTER)
480, Kamifujisawa, Iruma, Saitama 358-8555, Japan
Phone 81-4-2962-5151 Fax 81-4-2962-6138 http://www.yaskawa.co.jp
YASKAWA AMERICA, INC.
2121 Norman Drive South, Waukegan, IL 60085, U.S.A.
Phone 1-800-YASKAWA (927-5292) or 1-847-887-7000 Fax 1-847-887-7310 http://www.yaskawa.com
YASKAWA ELÉTRICO DO BRASIL LTDA.
Avenida Piraporinha 777, Diadema, São Paulo, 09950-000, Brasil
Phone 55-11-3585-1100 Fax 55-11-3585-1187 http://www.yaskawa.com.br
YASKAWA EUROPE GmbH
Hauptstra β e 185, Eschborn 65760, Germany
Phone 49-6196-569-300 Fax 49-6196-569-398 http://www.yaskawa.eu.com
YASKAWA ELECTRIC KOREA CORPORATION
9F, Kyobo Securities Bldg. 26-4, Yeouido-dong, Yeongdeungpo-gu, Seoul, 150-737, Korea
Phone 82-2-784-7844 Fax 82-2-784-8495 http://www.yaskawa.co.kr
YASKAWA ELECTRIC (SINGAPORE) PTE. LTD.
151 Lorong Chuan, #04-02A, New Tech Park 556741, Singapore
Phone 65-6282-3003 Fax 65-6289-3003 http://www.yaskawa.com.sg
YASKAWA ELECTRIC (CHINA) CO., LTD.
12F, Carlton Bld., No.21 HuangHe Road, HuangPu District, Shanghai 200003, China
Phone 86-21-5385-2200 Fax 86-21-5385-3299 http://www.yaskawa.com.cn
YASKAWA ELECTRIC (CHINA) CO., LTD. BEIJING OFFICE
Room 1011, Tower W3 Oriental Plaza, No.1 East Chang An Ave.,
Dong Cheng District, Beijing 100738, China
Phone 86-10-8518-4086 Fax 86-10-8518-4082
YASKAWA ELECTRIC TAIWAN CORPORATION
9F, 16, Nanking E. Rd., Sec. 3, Taipei 104, Taiwan
Phone 886-2-2502-5003 Fax 886-2-2505-1280
YASKAWA ELECTRIC CORPORATION
In the event that the end user of this product is to be the military and said product is to be employed in any weapons systems or the manufacture thereof, the export will fall under the relevant regulations as stipulated in the Foreign Exchange and Foreign Trade Regulations. Therefore, be sure to follow all procedures and submit all relevant documentation according to any and all rules, regulations and laws that may apply.
Specifications are subject to change without notice for ongoing product modifications and improvements.
© 2012-2014 YASKAWA ELECTRIC CORPORATION. All rights reserved.