advertisement
▼
Scroll to page 2
of
22
![Elko SHT-1, SHT-1/2, SHT-3/2 Manual | Manualzz Elko SHT-1, SHT-1/2, SHT-3/2 Manual | Manualzz](http://s3.manualzz.com/store/data/065081542_1-e8fca73693ee6f1832f0cdfcb2fd38e3-360x466.png)
Digital time switch clock SHT-1 SHT-1/2 SHT-3 SHT-3/2 E N Content Warning .......................................................................................................... 3 Characteristics ............................................................................................... 4 Technical parameters .................................................................................... 5 Description .................................................................................................... 6 Symbol, Connection ...................................................................................... 8 Versions of time switches, Load ................................................................... 9 Mode precendence, Manual output control ............................................... 10 Control ............................................................................................................ 11 Program setting ............................................................................................. 12 Program adjustment ..................................................................................... 13 Program deleting, Deleting of all programs ............................................... 14 Date and time setting ................................................................................... 15 Setting of programmed/random mode ....................................................... 16 Setting of pulse/cyclic mode interval .......................................................... 17 Holiday mode ................................................................................................ 18 Exit from menu .............................................................................................. 19 Example of programming ............................................................................ 20 Reset .............................................................................................................. 21 2 Warning E N Device is constructed for connection in 1-phase main alternating current voltage and must be installed according to norms valid in the state of application. Connection according to the details in this direction. Installation, connection, setting and servicing should be installed by qualified electrician staff only, who has learnt these instruction and functions of the device. This device contains protection against overvoltage peaks and disturbancies in supply. For correct function of the protection of this device there must be suitable protections of higher degree (A, B, C) installed in front of them. According to standards elimination of disturbancies must be ensured. Before installation the main switch must be in position “OFF” and the device should be de-energized. Don´t install the device to sources of excessive electro-magnetic interference. By correct installation ensure ideal air circulation so in case of permanent operation and higher ambient temperature the maximal operating temperature of the device is not exceeded. For installation and setting use screw-driver cca 2 mm. The device is fully-electronic - installation should be carried out according to this fact. Nonproblematic function depends also on the way of transportation, storing and handling. In case of any signs of destruction, deformation, non-function or missing part, don´t install and claim at your seller it is possible to dismount the device after its lifetime, recycle, or store in protective dump. 3 Characteristics - Set time of pulse/delay is on one channel the same for all programs (it is not possible to set more pulses with different durations on one channel). - “Holiday mode - #“ - possibility to choose the period, when the device will be not switching according a standard program and will be blocked for the pre-set time. - 100 memory positions (by SHT-1/2 and SHT-3/2 are those 100 positions common for both channels). - Programming of device can be realize even under voltage and also even in back-up mode. - Output relays operates only under voltage. - Automatic change-over between summer/winter time (setting is for time zone GTM+1:00). - Back-lighted LCD display. - Easy and quick setting by 4 control buttons. - Sealable transparent cover of the front panel. - Time switch is back-up with in-built lithium element, which saves data during voltage failure. Back-up time reserve - up to 3 years. - Supply voltage: AC 230V or AC/DC 12-240V. - 2-Module, DIN rail mounting, saddle terminals. - Serves for controlling of various types of appliances in dependance on real time (automation-switching of heating, pumps, ventilation etc.). Appliances can be operated in concrete periodic time cycles or according a pre-set program (depends on type, see the chart Versions of time switches). - SHT-1, SHT-3: 1-channel version. - SHT-1/2, SHT-3/2: 2-channel version (to each channel can be assigned an individual program). - Possibility to control two independent circuits. - By SHT-3, SHT-3/2 is not possible to integrate daily and night mode on one channel. By SHT-3/2 is possible to set a different mode on each channel. - Setting of switching by: - program (PROG) - switching according programs set in SET 1 . Possibility to set the repeat every minute or every hour. - random (AUTO ) - random switching in 10-120 min interval. - permanently manualy . - Switching modes (OUT): - OUT ON - normal - 2 positions in memory (close /open), shortest time of closing is 1 min. - Device is delivered with pre-programmed actual time, which is - OUT ON - cyclic - 2 positions in memory (pulse/delay), range permanently displayed also in back-up mode. 1-99s. - OUT ON - pulse - 1 position in memory, range 1-99s. - OUT OFF - turn off the switching mode. 4 Supply terminals: Supply voltage: Consumption: Supply voltage: Consumption: Supply voltage tolerance: Real time back-up: Summer/winter time: Output: Number of contacts: - SHT-1, SHT-3: - SHT-1/2, SHT-3/2: Rated current: Switching capacity: Peak current: Switching voltage: Mechanical life: Electrical life (AC1): Time circuit Real time back-up when de-energi.: Accuracy: Minimum interval: Data stored for: Cyclic output: 230 UNI Technical parameters A1 - A2 AC/DC 12-240V (AC 50-60Hz) AC 0.5 - 2VA / DC 0.4 - 2W AC 230V / 50 - 60Hz AC max. 14VA / 2W -15 %; +10 % yes automatic 1 x changeover (AgSnO2) 2 x changeover (AgSnO2) 16A / AC1 4000 VA / AC1, 384W / DC 30A / <3s 250V AC1 / 24V DC > 3x107 > 0.7x105 up to 3 years max. ±1s/ day at 23°C 1 min. min. 10 years 1-99s Pulse output: Program circuit Number of memory places: Program (SHT-1, SHT-1/2): Program(SHT-3, SHT-3/2): Data readout: Other information Operating temperature: Storage temperature: Electrical strength: Operating position: Mounting: Protection degree: Overvoltage category: Pollution degree: Max. cable size (mm2): Dimensions: Weight - SHT-1, SHT-3: - SHT-1/2, SHT-3/2: Standards: 1-99s E N 100 daily, weekly daily, weekly, monthly, yearly (up to year 2095) LCD display, with back light -20.. +55 °C -30.. +70 °C 4 kV (supply - output) any DIN rail EN 60715 IP10 clips, IP40 from front panel III. 2 solid wire max. 2x 2.5 or 1x 4 with sleeve max. 1x 2.5 or 2x 1.5 90 x 35.6 x 64 mm (UNI)-130 g, (230)-110 g (UNI)-143 g, (230)-125 g EN 61812-1, EN 61010-1 5 Description Output - channel 1 (16-15-18) Supply voltage terminal (A1) Display with back-light Control buttons Place for seal Supply voltage terminal (A2) Output - channel 2 (26-25-28) 6 Indicates the day in the week Operating modes indication Indication (1st channel) 1 2 3 4 5 6 Auto Prog Man 7 Indication (2nd channel) Indicates 12 / 24 mode Indication of time/date/setting menu Indicates summer / winter mode Bargraf 0 6 12 18 Control button PRG / + 24 Control button MAN2 / ESC Reset Control button OK Control button MAN1 / - CONTROL OF A DISPLAY WITH BACKLIGHT Display is illuminated with a back-light for 10 s from last button press. Permanent on / off is activated by synchronic press of buttons MAN, ESC, OK. After permanent on/off activation, display will flash shortly. 7 E N Symbol SHT-1 SHT-3 A1 16 18 A2 15 SHT-1/2 SHT-3/2 A1 A2 16 18 26 28 15 Connection SHT-1 SHT-3 A1 16 15 18 Un A1 16 15 18 Un A2 8 SHT-1/2 SHT-3/2 A2 26 25 28 25 Versions of time switches output Type of product 1 channel SHT-1 z SHT-3 2 channels z SHT-1/2 z z SHT-3/2 E N time program day week month year z z z z z z z z z z z z Load Type of load Contact material AgSnO2, Contact 16A cos φ ≥ 0.95 M M AC1 AC2 AC3 AC5a Uncompensated 250V / 16A 250V / 5A 250V / 3A AC6a AC7b x HAL.230V 230V / 3A (690VA) AC5a Compensated 230V / 3A (690VA) max. input C=14uF 1000W AC12 AC13 AC14 AC15 250V / 3A x x 250V / 6A 250V / 6A M M Type of load Contact material AgSnO2, Contact 16A K Type of load Contact material AgSnO2, Contact 16A AC5b DC1 DC3 DC5 DC12 DC13 DC14 24V / 10A 24V / 3A 24V / 2A 24V / 6A 24V / 2A x 9 Mode precendence Precendence of controlling modes highest priority of controlling mode display output mode ON / OFF manual control ON / OFF # holiday mode ON / OFF auto lowest priority of controlling mode ON / OFF pulse-cyclic mode / ON / OFF random mode for switching normal mode Prog Manual output control - is superior to other set modes 4 4 4 Man 0 6 12 18 0 6 12 18 relay on 0 6 12 18 24 0 6 12 18 24 - controls channel 1 24 24 4 Man relay off 10 - controls channel 2 (by SHT-1/2 and SHT-3/2) Control Prog 6 12 18 24 - entrance into programming menu 0 setting, adjustment and program deleting Device differs short and long button press. In the manual marked as: - short button press (<1s) - long button press (>1s) c/d - number indicates button press sequence - quick shifting during setting of values - browsing in menu - setting of values 0 6 12 18 24 Man 6 12 12 18 18 24 24 setting of pulse /cyclic mode interval 12 18 - entrance into chosen program (EDIT) - one level up 6 - entrance into required menu - confirmation holiday mode 0 0 6 setting of programmed / random mode 0 date and time setting - back to the starting menu 24 exit from menu 0 6 12 18 24 After 30s of inactivity (from the last press of any button) will device automatically returns into starting menu. 11 E N SET 1 Program setting 4 Man 0 6 12 18 24 7 6 5 0 6 12 18 0 24 6 12 18 24 4 3 0 0 Prog 6 0 6 12 18 6 12 18 24 2 24 0 24 6 12 18 24 0 6 12 18 24 1 24 24 Prog 24 0 6 12 18 24 24 24 18 24 6 12 18 24 6 12 18 0 6 12 24 0 6 12 24 0 6 12 24 0 6 12 18 12 18 0 d setting of hour and minute of program start /end 6 12 18 24 ............ 0 6 12 18 24 d c 24 only by yearly mode: setting of year, month and day 6 d c 0 24 d c OUT - setting of switching mode - OUT ON - normal - OUT ON - cyclic - OUT ON - pulse - OUT OFF - turn off the switching mode 18 d c If the program memory is full, display announces it by notice FULL. 12 18 d c by SHT-3 and SHT-3/2 - selection of daily / night mode 18 c 24 by SHT1/2 and SHT3/2 - selection of channel 0 0 ADD - add a new program 12 6 0 24 18 12 6 0 only by daily mode: ON/OFF - setting of the program activity in concrete day of the week SET 1 Program adjustment 4 E N Man 0 6 12 18 24 7 6 5 0 6 12 18 0 24 6 12 18 24 4 3 0 4 0 Prog 6 0 6 12 18 6 12 18 0 24 24 2 24 6 12 18 24 0 6 12 18 24 24 1 4 24 Man 24 0 6 12 18 24 24 24 24 0 12 18 0 6 12 24 0 6 12 24 0 6 12 18 0 6 12 0 6 12 24 0 6 12 18 0 6 12 dc 24 0 d time adjustment (hours / minutes) 6 12 18 24 0 6 12 18 24 only by yearly mode: adjusting of date (year, month and day) 18 dc 24 dc OUT - selection / adjustment of switching mode 18 dc 24 - by SHT-3 and SHT-3/2 selection / adjustment of set mode 18 dc 24 oc - by SHT-1/2 and SHT-3/2 selection / adjustment of channel 18 c 18 selection / entrance into chosen program 24 d 6 c EDIT - adjustment of already saved programs 18 12 6 0 24 18 12 6 0 only by daily mode: ON/OFF - selection / adjustment of program activity in concrete day of the week - long press (>1s) - short press (<1s) c/d - press sequence 13 SET 1 Program deleting Deleting of all programs 4 Man 0 6 12 18 24 4 12 18 24 0 6 12 18 0 12 18 24 6 12 18 0 6 DEL - deleting of individual programs 14 - long press OK deleting of chosen program 24 0 6 12 18 24 0 6 12 18 24 in starting menu (time is shown on display) - press simultaneously button PRG and OK and display announces a notice ALL 0 6 12 18 24 program selection 18 Man o 12 c 24 0 d 6 c 24 6 0 4 Man 4 Prog press button OK to complete the deleting of all set programs SET 2 Date and time setting 4 E N Man 0 6 12 18 24 24 6 12 18 6 12 18 12 18 6 12 18 6 12 18 6 12 18 d minutes setting 0 6 12 12 18 18 c 24 24 0 6 12 18 24 d c 24 6 hour setting 0 c 24 setting of time in 24 or 12 hour format d 0 c 24 d 0 c 24 day setting 6 d 0 c 24 month setting d 0 c 24 0 0 24 18 18 12 year setting 6 0 12 24 18 12 6 0 6 0 Prog d activation of changeover between summer/winter time - long press (>1s) - short press (<1s) c/d - press sequence 15 SET 3 Setting of programmed / random mode 4 Man 6 12 18 24 Auto 0 6 0 Man 12 0 6 12 18 24 6 12 18 0 Prog 0 d 6 6 12 c PROG - relay is switching according programs set in menu SET 1 12 18 18 24 24 Man 0 6 12 18 24 In starting mode by chosen channel flashs symbol Prog or 24 24 c - by SHT-1/2 and SHT-3/2 - selection of channel 16 18 0 24 18 6 Prog 0 d AUTO - relay is switching randomly in 10-120 min interval on display (automatically preset switching according PROG). SET 4 Setting of pulse / cyclic mode interval 4 E N Man 0 6 12 18 24 12 0 6 12 18 24 6 12 18 18 c 24 d setting of pulse /cycle duration 0 6 12 18 c 24 0 6 12 18 24 Setting of time of pulse / cyclic mode switching is realized by SET 1 . 12 by SHT-1/2 and SHT-3/2 selection of channel 6 d 0 c 24 0 24 18 6 0 6 0 Prog d setting of delay / cycle duration (by - pulse mode do not set) - long press (>1s) - short press (<1s) c/d - press sequence 17 SET 5 Holiday mode 4 Man 0 6 12 18 24 24 24 0 6 12 18 6 12 18 0 6 12 24 0 6 12 18 6 12 18 12 18 24 6 12 holiday mode ending month setting 18 c 24 0 6 12 18 d 0 18 6 d c holiday mode ending year setting In the starting mode during the activation of holiday mode, flashs symbol # on display. 0 d c 24 holiday mode starting day setting 0 d c 24 d c holiday mode starting month setting 18 c 24 holiday mode starting year setting d 0 c 24 18 holiday mode setting 12 6 0 24 18 12 6 0 Prog d holiday mode ending day setting 24 End Exit from menu - return to the starting mode 4 E N Man 6 12 18 24 4 Prog 0 6 Man 12 18 24 0 6 12 18 24 0 6 12 18 24 0 - long press (>1s) - short press (<1s) c/d - press sequence 19 Example of programming Setting of SHT-3/2 to be activated from Monday till Friday at 8:00 by program 0 ( 1( ). ) , and deactivated from Monday till Friday at 16:30 by program 5 4 setting of switching on 3 7 2 4 1 6 24 Prog Man 24 24 24 24 0 6 12 18 24 0 6 12 0 6 12 18 24 0 12 0 24 12 18 24 0 12 18 0 6 12 18 6 5 4 7 2 6 24 4 Prog 24 24 24 24 0 6 12 18 24 0 6 12 18 18 24 dsetting of activity Mo-Fri 0 6 12 18 c 24 0 6 d turning off the activity Sat-Sun 12 18 24 ............ save 0 6 12 18 24 20 turning off 12 normal mode 6 daily program 0 d timec dturnc off a of 24 c 24 18 12 6 0 return into starting menu 0 6 12 18 24 setting of activity Mo-Fri 3 1 18 24 0 6 12 18 c 24 d time of turning on 12 d c turn on a normal mode 0 24 d c daily program 24 d c 6 channel 1 6 c add the program program 0 18 6 programming 24 starting menu 18 24 18 12 6 0 d turning off the activity Sat-Sun Reset E N setting of switching off 1 0 6 12 18 24 ............ 0 6 12 18 24 0 6 12 18 24 12 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 save 18 c1 d program 1 channel Activated by, covered RESET button, short press with blunt spike (with max. 2 mm diameter). After press, information about type of device and firmware version will displayed for 3 s and then device performs in starting mode. Reset will delete an actual time, set time of pulse/cyclic mode and all temporary functions (manual or random switch output). Reset will save all set programs. - long press (>1s) - short press (<1s) c/d - press sequence 21 ELKO EP, s.r.o. Palackého 493, 769 01 Holešov, Všetuly Czech Republic Tel.: +420 573 514 211 e-mail: [email protected], www.elkoep.com 02-71/2017 Rev.: 1 22
advertisement