Digital time switch clock
SHT-1
SHT-1/2
SHT-3
SHT-3/2
E
N
Content
Warning .......................................................................................................... 3
Characteristics ............................................................................................... 4
Technical parameters .................................................................................... 5
Description .................................................................................................... 6
Symbol, Connection ...................................................................................... 8
Versions of time switches, Load ................................................................... 9
Mode precendence, Manual output control ............................................... 10
Control ............................................................................................................ 11
Program setting ............................................................................................. 12
Program adjustment ..................................................................................... 13
Program deleting, Deleting of all programs ............................................... 14
Date and time setting ................................................................................... 15
Setting of programmed/random mode ....................................................... 16
Setting of pulse/cyclic mode interval .......................................................... 17
Holiday mode ................................................................................................ 18
Exit from menu .............................................................................................. 19
Example of programming ............................................................................ 20
Reset .............................................................................................................. 21
2
Warning
E
N
Device is constructed for connection in 1-phase
main alternating current voltage and must be installed according to norms valid in the state of
application. Connection according to the details
in this direction. Installation, connection, setting and servicing should be installed by qualified electrician staff only, who
has learnt these instruction and functions of the device. This
device contains protection against overvoltage peaks and
disturbancies in supply. For correct function of the protection
of this device there must be suitable protections of higher degree (A, B, C) installed in front of them. According to standards
elimination of disturbancies must be ensured. Before installation the main switch must be in position “OFF” and the device
should be de-energized. Don´t install the device to sources of
excessive electro-magnetic interference. By correct installation
ensure ideal air circulation so in case of permanent operation
and higher ambient temperature the maximal operating temperature of the device is not exceeded. For installation and setting use screw-driver cca 2 mm. The device is fully-electronic
- installation should be carried out according to this fact. Nonproblematic function depends also on the way of transportation, storing and handling. In case of any signs of destruction,
deformation, non-function or missing part, don´t install and
claim at your seller it is possible to dismount the device after its
lifetime, recycle, or store in protective dump.
3
Characteristics
- Set time of pulse/delay is on one channel the same for all programs (it is not possible to set more pulses with different durations on one channel).
- “Holiday mode - #“ - possibility to choose the period, when
the device will be not switching according a standard program
and will be blocked for the pre-set time.
- 100 memory positions (by SHT-1/2 and SHT-3/2 are those 100
positions common for both channels).
- Programming of device can be realize even under voltage and
also even in back-up mode.
- Output relays operates only under voltage.
- Automatic change-over between summer/winter time (setting
is for time zone GTM+1:00).
- Back-lighted LCD display.
- Easy and quick setting by 4 control buttons.
- Sealable transparent cover of the front panel.
- Time switch is back-up with in-built lithium element, which
saves data during voltage failure. Back-up time reserve - up to
3 years.
- Supply voltage: AC 230V or AC/DC 12-240V.
- 2-Module, DIN rail mounting, saddle terminals.
- Serves for controlling of various types of appliances in dependance on real time (automation-switching of heating, pumps,
ventilation etc.). Appliances can be operated in concrete periodic time cycles or according a pre-set program (depends on
type, see the chart Versions of time switches).
- SHT-1, SHT-3: 1-channel version.
- SHT-1/2, SHT-3/2: 2-channel version (to each channel can be
assigned an individual program).
- Possibility to control two independent circuits.
- By SHT-3, SHT-3/2 is not possible to integrate daily and night
mode on one channel. By SHT-3/2 is possible to set a different
mode on each channel.
- Setting of switching by:
- program (PROG) - switching according programs set in SET 1
. Possibility to set the repeat every minute or every hour.
- random (AUTO ) - random switching in 10-120 min interval.
- permanently manualy .
- Switching modes (OUT):
- OUT ON - normal - 2 positions in memory (close /open), shortest time of closing is 1 min.
- Device is delivered with pre-programmed actual time, which is
- OUT ON - cyclic - 2 positions in memory (pulse/delay), range
permanently displayed also in back-up mode.
1-99s.
- OUT ON - pulse - 1 position in memory, range 1-99s.
- OUT OFF - turn off the switching mode.
4
Supply terminals:
Supply voltage:
Consumption:
Supply voltage:
Consumption:
Supply voltage tolerance:
Real time back-up:
Summer/winter time:
Output:
Number of contacts:
- SHT-1, SHT-3:
- SHT-1/2, SHT-3/2:
Rated current:
Switching capacity:
Peak current:
Switching voltage:
Mechanical life:
Electrical life (AC1):
Time circuit
Real time back-up when
de-energi.:
Accuracy:
Minimum interval:
Data stored for:
Cyclic output:
230 UNI
Technical parameters
A1 - A2
AC/DC 12-240V (AC 50-60Hz)
AC 0.5 - 2VA / DC 0.4 - 2W
AC 230V / 50 - 60Hz
AC max. 14VA / 2W
-15 %; +10 %
yes
automatic
1 x changeover (AgSnO2)
2 x changeover (AgSnO2)
16A / AC1
4000 VA / AC1, 384W / DC
30A / <3s
250V AC1 / 24V DC
> 3x107
> 0.7x105
up to 3 years
max. ±1s/ day at 23°C
1 min.
min. 10 years
1-99s
Pulse output:
Program circuit
Number of memory places:
Program (SHT-1, SHT-1/2):
Program(SHT-3, SHT-3/2):
Data readout:
Other information
Operating temperature:
Storage temperature:
Electrical strength:
Operating position:
Mounting:
Protection degree:
Overvoltage category:
Pollution degree:
Max. cable size (mm2):
Dimensions:
Weight
- SHT-1, SHT-3:
- SHT-1/2, SHT-3/2:
Standards:
1-99s
E
N
100
daily, weekly
daily, weekly, monthly, yearly
(up to year 2095)
LCD display, with back light
-20.. +55 °C
-30.. +70 °C
4 kV (supply - output)
any
DIN rail EN 60715
IP10 clips, IP40 from front panel
III.
2
solid wire max. 2x 2.5 or 1x 4
with sleeve max. 1x 2.5 or 2x 1.5
90 x 35.6 x 64 mm
(UNI)-130 g, (230)-110 g
(UNI)-143 g, (230)-125 g
EN 61812-1, EN 61010-1
5
Description
Output - channel 1 (16-15-18)
Supply voltage terminal (A1)
Display with back-light
Control buttons
Place for seal
Supply voltage terminal (A2)
Output - channel 2 (26-25-28)
6
Indicates the day in the week
Operating modes indication
Indication (1st channel)
1 2 3 4 5 6
Auto Prog Man
7
Indication (2nd channel)
Indicates 12 / 24 mode
Indication of time/date/setting menu
Indicates summer / winter mode
Bargraf
0
6
12
18
Control button PRG / +
24
Control button MAN2 / ESC
Reset
Control button OK
Control button MAN1 / -
CONTROL OF A DISPLAY WITH BACKLIGHT
Display is illuminated with a back-light for 10 s from last button press.
Permanent on / off is activated by synchronic press of buttons MAN, ESC, OK.
After permanent on/off activation, display will flash shortly.
7
E
N
Symbol
SHT-1
SHT-3
A1
16 18
A2
15
SHT-1/2
SHT-3/2
A1
A2
16 18 26 28
15
Connection
SHT-1
SHT-3
A1 16 15 18
Un
A1 16 15 18
Un
A2
8
SHT-1/2
SHT-3/2
A2 26 25 28
25
Versions of time switches
output
Type of product
1 channel
SHT-1
z
SHT-3
2 channels
z
SHT-1/2
z
z
SHT-3/2
E
N
time program
day
week
month
year
z
z
z
z
z
z
z
z
z
z
z
z
Load
Type of load
Contact material AgSnO2,
Contact 16A
cos φ ≥ 0.95
M
M
AC1
AC2
AC3
AC5a
Uncompensated
250V / 16A
250V / 5A
250V / 3A
AC6a
AC7b
x
HAL.230V
230V / 3A (690VA)
AC5a
Compensated
230V / 3A (690VA)
max. input C=14uF
1000W
AC12
AC13
AC14
AC15
250V / 3A
x
x
250V / 6A
250V / 6A
M
M
Type of load
Contact material AgSnO2,
Contact 16A
K
Type of load
Contact material AgSnO2,
Contact 16A
AC5b
DC1
DC3
DC5
DC12
DC13
DC14
24V / 10A
24V / 3A
24V / 2A
24V / 6A
24V / 2A
x
9
Mode precendence
Precendence of controlling
modes
highest priority of
controlling mode
display
output mode
ON / OFF
manual control

ON / OFF #
holiday mode

ON / OFF auto


lowest priority of
controlling mode
ON / OFF
pulse-cyclic mode
/
ON / OFF

random mode for switching
normal mode
Prog
Manual output control - is superior to other set modes
4
4
4
Man
0
6
12
18
0
6
12
18
relay on
0
6
12
18

24
0
6
12
18
24
- controls channel 1


24




24
4
Man

relay off


10
- controls channel 2
(by SHT-1/2 and SHT-3/2)
Control
Prog
6
12
18
24
- entrance into programming menu

0
setting, adjustment
and program deleting
Device differs short and long button press. In the manual marked
as:
- short button press (<1s)
- long button press (>1s)
c/d - number indicates button press sequence

- quick shifting during setting of values





- browsing in menu
- setting of values

0
6
12
18
24
Man
6
12
12
18
18

24
24
setting of pulse /cyclic mode
interval
12
18
- entrance into chosen program (EDIT)

- one level up

6
- entrance into required menu
- confirmation

holiday mode
0


0
6
setting of programmed /
random mode

0

date and time setting
- back to the starting menu

24

exit from menu
0
6
12
18
24
After 30s of inactivity (from the last press of any button) will device
automatically returns into starting menu.
11
E
N
SET 1 Program setting
4
Man
0
6
12
18
24
7
6

5
0

6
12
18
0
24
6
12
18
24
4
3
0
0
Prog
6
0
6
12
18
6
12
18
24
2
24
0
24
6
12
18
24
0
6
12
18
24
1
24
24
Prog
24
0
6
12
18
24
24
24
18
24
6
12
18
24
6
12
18
0
6
12
24
0
6
12
24
0
6
12
24
0
6
12
18
12
18
0
d
setting of hour and
minute of program
start /end
6
12
18
24
............
0
6
12
18
24

d c
24

only by yearly
mode: setting
of year, month
and day
6

d c
0
24


d c
OUT - setting of
switching mode
- OUT ON - normal
- OUT ON
- cyclic
- OUT ON
- pulse
- OUT OFF - turn off the
switching mode
18


d c
If the program memory is full, display announces it by notice FULL.
12
18


d c
by SHT-3 and
SHT-3/2
- selection of daily /
night mode
18


 c
24

by SHT1/2 and
SHT3/2 - selection
of channel
0


0

ADD - add a new
program
12



6

0

24

18

12

6

0

only by daily mode:
ON/OFF - setting of
the program activity in concrete day
of the week
SET 1 Program adjustment
4
E
N
Man
0
6
12
18
24
7
6

5
0

6
12
18
0
24
6
12
18
24
4
3
0
4
0
Prog
6
0
6
12
18
6
12
18
0
24
24
2
24
6
12
18
24
0
6
12
18
24
24
1
4
24
Man
24
0
6
12
18
24
24
24
24
0
12
18
0
6
12
24
0
6
12
24
0
6
12
18
0
6
12
0
6
12
24
0
6
12
18
0
6
12
dc
24
0
d
time
adjustment
(hours /
minutes)
6
12
18
24
0
6
12
18
24

only by yearly
mode: adjusting
of date (year,
month and day)
18

dc
24


dc
OUT - selection /
adjustment of
switching mode
18


dc
24

- by SHT-3 and
SHT-3/2
selection /
adjustment of set
mode
18

dc
24


oc
- by SHT-1/2 and
SHT-3/2
selection / adjustment of channel
18


 c
18


selection /
entrance into
chosen program
24

d
6




c
EDIT - adjustment
of already saved
programs
18

12

6

0

24

18

12

6

0

only by daily
mode: ON/OFF
- selection /
adjustment of
program activity
in concrete day of
the week
- long press (>1s)
- short press (<1s)
c/d - press sequence
13
SET 1 Program deleting
Deleting of all programs
4
Man
0
6
12
18
24


4
12
18
24
0
6
12
18
0
12
18
24
6
12
18
0
6
DEL - deleting of
individual programs
14
- long press OK deleting of chosen
program
24

0
6
12
18
24
0
6
12
18
24

in starting menu
(time is shown on
display) - press
simultaneously
button PRG and OK
and display
announces a notice
ALL
0
6
12
18
24

program selection
18
Man

o
12

c
24


0

d
6




 c
24

6

0
4
Man

4
Prog

press button OK
to complete the
deleting of all set
programs
SET 2 Date and time setting
4
E
N
Man
0
6
12
18
24


24
6
12
18
6
12
18
12
18
6
12
18
6
12
18
6
12
18
d
minutes
setting
0
6
12
12
18
18
c
24
24
0
6
12
18
24

d c
24
6

hour
setting
0

c
24

setting of time in 24
or 12 hour format
d
0

c
24

d
0

c
24

day
setting
6

d
0

c
24

month
setting
d
0

c
24


0
0
24

18
18

12

year
setting
6



0
12

24

18

12

6

0
6

0
Prog
d
activation of
changeover between
summer/winter time
- long press (>1s)
- short press (<1s)
c/d - press sequence
15
SET 3 Setting of programmed / random mode
4
Man
6
12
18
24

Auto

0
6
0
Man
12
0
6
12
18
24
6
12
18
0
Prog
0
d
6
6
12
c
PROG
- relay is switching
according programs
set in menu SET 1
12
18
18
24
24
Man
0
6
12
18
24

In starting mode by chosen channel flashs symbol Prog or
24
24

c
- by SHT-1/2 and
SHT-3/2 - selection
of channel
16
18


0


24



18
6

Prog

0
d
AUTO
- relay is switching
randomly in
10-120 min interval
on display (automatically preset switching according PROG).
SET 4 Setting of pulse / cyclic mode interval
4
E
N
Man
0
6
12
18
24


12
0
6
12
18
24
6
12
18
18
c
24
d
setting of
pulse /cycle
duration
0
6
12
18
c
24
0
6
12
18
24

Setting of time of pulse / cyclic mode switching is realized by SET 1 .
12

by SHT-1/2 and
SHT-3/2
selection of channel
6

d
0

c
24


0


24



18

6

0
6

0
Prog
d
setting of
delay / cycle duration
(by - pulse mode
do not set)
- long press (>1s)
- short press (<1s)
c/d - press sequence
17
SET 5 Holiday mode
4
Man
0
6
12
18
24


24
24
0
6
12
18
6
12
18
0
6
12
24
0
6
12
18
6
12
18
12
18
24
6
12
holiday mode
ending month
setting
18
c
24
0
6
12
18

d
0


18
6
d c
holiday mode
ending year setting
In the starting mode during the activation of holiday mode, flashs symbol # on display.
0

d c
24

holiday mode
starting day setting
0

d c
24


d c
holiday mode
starting month
setting
18


c
24

holiday mode
starting year setting
d
0

 c
24


18

holiday mode
setting
12



6

0

24

18

12

6

0

Prog
d
holiday mode
ending day setting
24
End Exit from menu - return to the starting mode
4
E
N
Man
6
12
18
24


4
Prog
0
6
Man
12
18

24
0
6
12
18
24
0
6
12
18
24



0

- long press (>1s)
- short press (<1s)
c/d - press sequence
19
Example of programming
Setting of SHT-3/2 to be activated from Monday till Friday at 8:00 by program 0 (
1(
).
) , and deactivated from Monday till Friday at 16:30 by program
5
4
setting of switching on
3
7
2
4
1
6
24
Prog
Man
24
24
24
24
0
6
12
18
24
0
6
12
0
6
12
18
24
0
12
0
24
12
18
24
0
12
18
0
6
12
18
6

5
4
7
2
6
24
4
Prog
24
24
24
24
0
6
12
18
24
0
6
12
18
18
24
dsetting of 
activity Mo-Fri
0
6
12
18
c
24
0
6
d
turning off the
activity Sat-Sun
12
18
24
............

save
0
6
12
18
24

20
turning off
12

normal mode
6

daily program
0


d timec
dturnc
off a
of
24




c
24



18

12

6

0

return into
starting menu
0
6
12
18
24
setting of activity
Mo-Fri
3
1
18
24
0
6
12
18
c
24

d
time of turning
on
12


d c
turn on a
normal mode
0
24


d c
daily program
24

d c
6


channel 1
6

 c
add the program program 0
18


6



programming
24




starting menu
18

24

18

12

6

0
d
turning off the
activity Sat-Sun
Reset
E
N
setting of switching off
1
0
6
12
18
24
............
0
6
12
18
24
0
6
12
18
24
12
24
0
6
12
18
24
0
6
12
18
24
0
6
12
18
24





save
18
c1 d
 program 1  channel
Activated by, covered RESET button, short press with blunt spike (with max. 2 mm
diameter).
After press, information about type of device and firmware version will displayed for 3
s and then device performs in starting mode.
Reset will delete an actual time, set time of pulse/cyclic mode and all temporary
functions (manual or random switch output).
Reset will save all set programs.
- long press (>1s)
- short press (<1s)
c/d - press sequence
21
ELKO EP, s.r.o.
Palackého 493, 769 01 Holešov, Všetuly
Czech Republic
Tel.: +420 573 514 211
e-mail: [email protected], www.elkoep.com
02-71/2017 Rev.: 1