Elko SHT-1 is a programmable time switch clock, allowing you to automate various appliances like heating or ventilation systems based on real time. It features two channels to control different circuits individually. Choose between operating modes like permanent manual, random (10-120 min interval), or program (repeat every minute or hour). Set switching by program, easily add new programs, or adjust existing ones. It also has a holiday mode to disable the standard program for a specific period. With a built-in lithium element, it ensures data backup during voltage failure for up to 3 years.
advertisement
▼
Scroll to page 2
of
4
EN SHT-1, SHT-1/2, SHT-3, SHT-3/2 ELKO EP, s.r.o. Palackého 493 769 01 Holešov, Všetuly Czech Republic Tel.: +420 573 514 211 e-mail: [email protected] www.elkoep.com Digital time switch clock Made in Czech Republic 02-71/2017 Rev.: 2 Characteristics Symbol - Serves for controlling of various types of appliances in dependance on real time (automation-switching of heating, pumps, ventilation etc.). Appliances can be operated in concrete periodic time cycles or according a pre-set program (depends on type, see the chart Versions of time switches). SHT-1 SHT-3 A1 16 18 A2 15 SHT-1/2 SHT-3/2 16 18 26 28 A1 - SHT-1, SHT-3: 1-channel version. - SHT-1/2, SHT-3/2: 2-channel version (to each channel can be assigned an individual program). - Possibility to control two independent circuits. 15 A2 25 Connection - By SHT-3, SHT-3/2 is not possible to integrate daily and night mode on one channel. By SHT-3/2 is possible to set a different mode on each channel. SHT-1 SHT-3 SHT-1/2 SHT-3/2 A1 16 15 18 - Setting of switching by: - program (PROG) - switching according programs set in SET 1 . Possibility to set the repeat every minute or every hour. - random (AUTO ) - random switching in 10-120 min interval. - permanently manualy . Un - Switching modes (OUT): - OUT ON - normal - 2 positions in memory (close /open), shortest time of closing is 1 min. - OUT ON - cyclic - 2 positions in memory (pulse/delay), range 1-99s. - OUT ON - pulse - 1 position in memory, range 1-99s. - OUT OFF - turn off the switching mode. A1 16 15 18 Un A2 A2 26 25 28 Description - Set time of pulse/delay is on one channel the same for all programs (it is not possible to set more pulses with different durations on one channel). 5 - “Holiday mode #“ - possibility to choose the period, when the device will be not switching according a standard program and will be blocked for the pre-set time. 8 9 10 11 1 - 100 memory positions (by SHT-1/2 and SHT-3/2 are those 100 positions common for both channels). 12 1 2 3 4 5 6 Auto Prog Man 7 16 17 18 0 6 12 18 24 2 - Programming of device can be realize even under voltage and also even in back-up mode. 3 - Output relays operates only under voltage. - Automatic change-over between summer/winter time (setting is for time zone GTM+1:00). 19 13 14 6 20 15 4 - Back-lighted LCD display. - Easy and quick setting by 4 control buttons. 7 - Sealable transparent cover of the front panel. 1. Supply voltage terminal (A1) 15. Control button MAN1 / - - Time switch is back-up with in-built lithium element, which saves data during voltage failure. Back-up time reserve - up to 3 years. 2. Display with back-light 16. Indication (2nd channel) 3. Place for seal 17. Indicates 12 / 24 mode - Supply voltage: AC 230V or AC/DC 12-240V. 4. Supply voltage terminal (A2) 18. Indicates summer / winter mode - 2-Module, DIN rail mounting, saddle terminals. 5. Output - channel 1 (16-15-18) 19. Control button MAN2 / ESC 6. Control buttons 20. Control button OK - Device is delivered with pre-programmed actual time, which is permanently displayed also in back-up mode. 7. Output - channel 2 (26-25-28) 8. Indicates the day in the week CONTROL OF A DISPLAY WITH BACKLIGHT Display is illuminated with a back-light for 10 s from last button press. Permanent on / off is activated by synchronic press of buttons MAN, ESC, OK. After permanent on/off activation, display will flash shortly. 9. Operating modes indication 10. Indication (1st channel) 11. Indication of time/date/setting menu 12. Bargraf 13. Control button PRG / + 14. Reset Type of load cos φ ≥ 0.95 AC1 Mat. contacts AgSnO2, contact 16A 250V / 16A M AC2 250V / 5A AC3 250V / 3A HAL.230V AC5a uncompensated AC5a compensated AC5b AC6a AC7b AC12 230V / 3A (690VA) 230V / 3A (690VA) to max. input C=14uF 1000W x 250V / 3A x M M DC3 DC5 DC12 DC13 DC14 24V / 3A 24V / 2A 24V / 6A 24V / 2A x K Type of load Mat. contacts AgSnO2, contact 16A M AC13 AC14 AC15 DC1 x 250V / 6A 250V / 6A 24V / 10A 1/4 Technical parameters Versions of time switches SHT-1 Consumption: Supply voltage: Consumption: 230 Supply voltage: UNI Supply terminals: Supply voltage tolerance: Real time back-up: Summer/winter time: SHT-3 SHT-1/2 SHT-3/2 output A1 - A2 Type of product 1 channel AC/DC 12-240V (AC 50-60Hz) SHT-1 z AC 0.5 - 2VA / DC 0.4 - 2W SHT-1/2 AC 230V / 50 - 60Hz SHT-3 AC max. 14VA / 2W SHT-3/2 time program 2 channels day week z z z z z z z z z month year z z z z z z -15 %; +10 % yes Mode precendence automatic Output: Number of contacts: Rated current: Switching capacity: Peak current: Switching voltage: Mechanical life: Electrical life (AC1): Precendence of controlling modes 1 x changeover (AgSnO2) 2 x changeover (AgSnO2) 16A / AC1 highest priority of controlling mode 4000 VA / AC1, 384W / DC Accuracy: Minimum interval: 1 min. 4 Man 4 Man 6 12 18 0 24 daily, weekly, monthly, yearly 24 0 6 12 18 24 0 6 12 18 24 - controls channel 1 relay on relay off daily, weekly Program(SHT-3, SHT-3/2): 18 100 Program (SHT-1, SHT-1/2): 12 Program circuit 6 1-99s 0 Prog is superior to other set modes 4 1-99s Pulse output: - controls channel 2 (by SHT-1/2 and SHT-3/2) Control (up to year 2095) Data readout: normal mode min. 10 years Cyclic output: Number of memory places: pulse-cyclic mode / ON / OFF Manual output control 4 ON / OFF holiday mode random mode for switching Data stored for: ON / OFF # lowest priority of controlling mode up to 3 years manual control ON / OFF auto > 3x107 max. ±1s/ day at 23°C ON / OFF > 0.7x105 Real time back-up when de- output mode 250V AC1 / 24V DC Time circuit energi.: 30A / <3s display Prog setting, adjustment and program deleting LCD display, with back light 0 6 12 18 24 Other information Storage temperature: -30.. +70 °C 4 kV (supply - output) Operating position: any Protection degree: Overvoltage category: Pollution degree: Max. cable size (mm2): -20.. +55 °C Electrical strength: Mounting: Operating temperature: date and time setting 0 6 12 18 24 Man DIN rail EN 60715 setting of programmed /random mode IP10 clips, IP40 from front panel 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 III. setting of pulse /cyclic mode interval 2 solid wire max. 2x 2.5 or 1x 4 with sleeve max. 1x 2.5 or 2x 1.5 Dimensions: holiday mode 90 x 35.6 x 64 mm Weight - SHT-1, SHT-3: (UNI)-130 g, (230)-110 g - SHT-1/2, SHT-3/2: (UNI)-143 g, (230)-125 g Standards: EN 61812-1, EN 61010-1 exit from menu Device differs short and long button press. In the manual marked as: - short button press (<1s) - long button press (>1s) c/d - number indicates button press sequence Warning - entrance into programming menu Device is constructed for connection in 1-phase main alternating current voltage and must be installed according to norms valid in the state of application. Connection according to the details in this direction. Installation, connection, setting and servicing should be installed by qualified electrician staff only, who has learnt these instruction and functions of the device. This device contains protection against overvoltage peaks and disturbancies in supply. For correct function of the protection of this device there must be suitable protections of higher degree (A, B, C) installed in front of them. According to standards elimination of disturbancies must be ensured. Before installation the main switch must be in position “OFF” and the device should be de-energized. Don´t install the device to sources of excessive electro-magnetic interference. By correct installation ensure ideal air circulation so in case of permanent operation and higher ambient temperature the maximal operating temperature of the device is not exceeded. For installation and setting use screw-driver cca 2 mm. The device is fully-electronic - installation should be carried out according to this fact. Non-problematic function depends also on the way of transportation, storing and handling. In case of any signs of destruction, deformation, non-function or missing part, don´t install and claim at your seller it is possible to dismount the device after its lifetime, recycle, or store in protective dump. - quick shifting during setting of values - browsing in menu - setting of values - entrance into required menu - confirmation - entrance into chosen program (EDIT) - one level up - back to the starting menu After 30s of inactivity (from the last press of any button) will device automatically returns into starting menu. 2/4 SET 1 Program setting 7 6 5 0 6 12 18 0 24 6 12 18 24 4 3 0 4 0 Prog Man 6 0 6 12 18 6 12 18 24 2 24 0 24 6 12 18 24 0 6 12 18 24 1 24 24 Prog 24 0 6 12 18 24 24 24 6 12 18 0 24 6 12 18 0 6 12 18 0 6 12 18 24 6 12 18 24 6 12 18 6 12 18 24 12 18 0 24 6 12 18 24 6 12 18 0 24 ............ c d setting of hour and minute of program start /end * 0 6 12 18 24 c d by SHT-3 and SHT-3/2 only by yearly mode: OUT - setting of - selection of daily / setting of year, switching mode night mode month and day - OUT ON - normal - cyclic - OUT ON - OUT ON - pulse - OUT OFF - turn off the switching mode by SHT1/2 and SHT3/2 - selection of channel 6 c d 0 c d 0 24 c d 0 c ADD - add a new program 0 24 24 0 24 18 12 6 0 d only by daily mode: ON/OFF - setting of the program activity in concrete day of the week If the program memory is full, display announces it by notice FULL. * If “- -” (2 dashes) is set as the hour or minute value instead of a numerical value, the start / end of the program will be repeated every hour or every minute. Program adjustment 7 6 5 0 6 12 18 0 24 6 12 18 24 4 3 0 4 4 0 Prog Man 6 0 6 12 18 6 12 18 24 2 24 0 24 6 12 18 24 0 6 12 18 24 1 24 4 24 Man 24 0 6 12 18 24 24 24 24 0 12 18 6 18 24 0 6 18 24 6 12 18 24 6 12 18 6 18 0 24 6 12 18 24 Prog 0 6 12 18 24 0 6 12 18 24 6 12 24 0 18 24 0 6 12 18 24 0 6 12 18 6 12 18 24 0 0 6 12 18 24 6 12 18 24 press button OK to complete the deleting of all set programs 0 6 12 24 0 12 18 0 6 12 18 0 6 12 18 12 18 18 0 24 24 6 12 18 6 12 18 6 12 12 18 18 c 24 24 0 6 12 18 24 d minutes setting 0 6 c 24 d hour setting 0 c 24 d setting of time in 24 or 12 hour format 0 c d day setting 6 c d month setting 0 24 c d year setting 24 c 24 6 18 12 24 6 18 12 6 0 SET 3 24 0 18 d in starting menu (time is shown on display) - press simultaneously button PRG and OK and display announces a notice ALL program selection - long press OK - deleting of chosen program Prog 24 12 18 0 12 6 Date and time setting Man 6 24 o 4 0 0 Man c DEL - deleting of individual programs SET 2 12 d 6 c 18 0 24 4 24 18 only by daily mode: ON/OFF - selection / adjustment of program activity in concrete day of the week Man 18 12 c d time adjustment (hours / minutes) 4 12 6 Deleting of all programs 4 6 0 24 0 18 c d only by yearly mode: adjusting of date (year, month and day) Program deleting 4 Man 12 OUT - selection / adjustment of switching mode 6 c d 0 c d - by SHT-3 and SHT-3/2 selection / adjustment of set mode 12 c d - by SHT-1/2 and SHT-3/2 selection / adjustment of channel 0 24 c o selection / entrance into chosen program 0 c EDIT - adjustment of already saved programs 0 d 12 c 12 0 24 6 18 12 6 0 24 18 12 6 0 d activation of changeover between summer/winter time Setting of programmed / random mode Auto Prog 6 12 24 0 6 12 18 0 6 12 18 24 6 12 6 18 24 24 by SHT-1/2 and SHT-3/2 - selection of channel 0 6 6 12 12 18 c 18 24 Man 24 0 6 12 18 24 d 0 Prog c 18 0 24 18 0 0 Man Man 4 d PROG - relay is switching according programs set in menu SET 1 - relay is switching AUTO randomly in 10-120 min interval In starting mode by chosen channel flashs symbol Prog or on display (automatically preset switching according PROG). 3/4 - long press (>1s) - short press (<1s) c/d - press sequence SET 4 Setting of pulse / cyclic mode interval 12 18 24 0 6 12 18 0 24 6 12 18 18 24 6 12 18 0 6 12 18 24 c d setting of pulse / cycle duration 0 6 12 18 24 c d by SHT-1/2 and SHT-3/2 selection of channel 24 c 0 12 6 0 24 6 6 0 0 Prog Man 4 d setting of delay / cycle duration (by - pulse mode do not set) Setting of time of pulse / cyclic mode switching is realized by SET 1 . SET 5 Holiday mode 4 12 18 24 0 6 12 18 6 18 24 6 12 18 0 6 12 18 24 6 12 18 0 6 12 18 0 6 12 18 0 6 12 18 c d holiday mode ending month setting 24 0 6 12 18 24 c d holiday mode ending year setting 24 c d holiday mode starting day setting 24 c d holiday mode starting month setting 24 c d holiday mode starting year setting 0 c d holiday mode setting 24 c 0 12 0 24 6 0 24 18 12 6 0 24 Prog Man d holiday mode ending day setting In the starting mode during the activation of holiday mode, flashs symbol # on display. End Exit from menu - return to the starting mode 4 4 Prog Man 0 6 12 18 24 0 6 Man 12 18 24 0 6 12 18 0 6 12 18 24 24 Reset Activated by, covered RESET button, short press with blunt spike (with max. 2 mm diameter). 1 After press, information about type of device and firmware version will displayed for 3 s and then device performs in starting mode. 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 Reset will delete an actual time, set time of pulse/cyclic mode and all temporary functions (manual or random switch output). Reset will save all set programs. Example of programming Setting of SHT-3/2 to be activated from Monday till Friday at 8:00 by program 0 ( ) , and deactivated from Monday till Friday at 16:30 by program 1 ( ). 5 4 setting of switching on 3 4 1 6 24 Prog Man setting of switching off 7 2 24 24 24 6 12 18 0 24 6 12 0 6 12 24 0 6 12 18 6 12 18 0 6 12 18 24 12 18 12 18 24 6 12 18 6 12 18 24 ............ 6 12 18 0 24 program 1 6 12 18 c 24 save 0 d turning off the activity Sat-Sun 0 c 24 setting of activity Mo-Fri 0 d time of turning on 6 c turn on a normal mode 0 24 d 6 c d daily program 0 c d channel 1 24 c program 0 0 24 add the program 18 programming 24 starting menu 18 0 24 18 12 6 24 0 d channel 1 5 4 3 7 2 1 6 24 4 Prog 24 24 24 24 6 12 18 6 12 18 6 12 18 24 6 12 18 d turning off the activity Sat-Sun 0 6 12 18 24 ............ save 0 6 12 18 24 0 6 12 18 24 c 24 setting of activity Mo-Fri 0 d time of turning off 0 c 24 d turn off a normal mode 0 c 24 d daily program 0 c 24 18 12 6 0 return into starting menu 4/4 - long press (>1s) - short press (<1s) c/d - press sequence
advertisement
Key Features
- Controls various appliances based on real-time
- 1-channel version for controlling one independent circuit
- Multiple switching modes: normal, cyclic, and pulse
- Holiday mode for excluding specific periods from the schedule
- Backlit LCD display for easy viewing
- Intuitive control buttons for simple operation
- Backup system with lithium element for data retention during power outages
Related manuals
Frequently Answers and Questions
What types of appliances can the SHT-1 control?
The SHT-1 can control various types of appliances, including heating systems, pumps, and ventilation systems.
How many switching modes does the SHT-1 offer?
The SHT-1 offers three switching modes: normal, cyclic, and pulse.
Does the SHT-1 have a backup system?
Yes, the SHT-1 has a backup system with a built-in lithium element that saves data during voltage failures for up to 3 years.
Can the SHT-1 be programmed to exclude certain periods from the schedule?
Yes, the SHT-1 features a holiday mode that allows you to exclude specific periods from the programmed schedule.