ABB Distribution Cable Terminal Block Instructions

Add to My manuals
8 Pages

advertisement

ABB Distribution Cable Terminal Block Instructions | Manualzz

GE Energy

Industrial Solutions

GEH-706 Installation Instructions

Distribution Cable

Terminal Block

For Spectra

®

RMS Molded-Case Circuit Breakers with micro EntelliGuard

TM

Trip Units

For Catalog Number SDCTBA11C, SDCTBA22C

Circuit Breaker Accessory

• Neutral current sensor - black (for equipment ground fault) 1

• Neutral current sensor - white (for equipment ground fault) 1

Overview

The General Electric Distribution Cable Terminal Block is a modular attachment primarily used to provide an alternate means of input to Spectra ® RMS Molded-Case

Circuit Breakers with microEntelliGuard

Spectra ® RMS Breaker with micro EntelliGuard TM using

Terminal Block 11C

• Control power (+24vdc)

• Control power (-common)

• System communications (Comm. +)

• System communications (Comm. -)

• reduced energy let-through (RELT O +)

• ground fault alarm (GFA O +)

• ground fault alarm/ reduced energy let-through

(RELT/GFA O –)

• reduced energy let-through (RELT I +)

• reduced energy let-through (RELT I –)

TM Trip Units. The terminal block input/output connections are as follows:

Spectra ® RMS Breaker with micro EntelliGuard TM using

Terminal Block 22C

• Control power (+24vdc)

• Control power (-common)

• System communications (Comm. +)

• System communications (Comm. -)

• reduced energy let-through (RELT O +)

• ground fault alarm (GFA O +)

• ground fault alarm/ reduced energy let-through

(RELT/GFA O –)

• reduced energy let-through (RELT I +)

• reduced energy let-through (RELT I –)

• Neutral current sensor - black (for equipment ground fault) 1

• Neutral current sensor - white (for equipment ground fault) 1

• zone select interlock (ZSI I +)

• zone select interlock (ZSI I –)

• zone select interlock (ZSI O +)

• zone select interlock (ZSI O –)

• breaker position (Aux. Switch [RED] )

• breaker position (Aux. Switch [WHITE] )

• voltage A (must be from Voltage Module or Voltage

Conditioner Plate or Voltage Conditioner Assembly)

• voltage B (must be from Voltage Module or Voltage

Conditioner Plate or Voltage Conditioner Assembly)

• voltage C (must be from Voltage Module or Voltage

Conditioner Plate or Voltage Conditioner Assembly)

1 Neutral current sensor input is required for 3Ø /4W or 1Ø /3W systems. For 3Ø /3W systems, do not make any connections.

GEH-706 Installation Instructions

The Distribution Cable Terminal Block is used to carry a variety of electronic signals between Spectra ® RMS Molded

Case Circuit Breakers with microEntelliGuard TM Trip Units. These breakers are interconnected via daisy-chained terminal blocks with common power, communication wiring, and voltage wiring (SDCTBA22C only).

Figures 1 and 2 show how the Distribution Cable Terminal Block is used in a typical microEntelliGuard TM system.

Figure 1. Typical microEntelliGuard TM system utilizing the 11C Distribution Cable Terminal Block.

GEH-706 Installation Instructions

Figure 2. Typical microEntelliGuard TM system utilizing the 22C Distribution Cable Terminal Block.

Figure 3 shows the individual breaker input connector pinout for the Distribution Cable Terminal Blocks.

Figure 3. End view of Distribution Cable Terminal Block cable detailing available breaker pinout connections.

GEH-706 Installation Instructions

Dimensions and Wiring Diagrams

A Distribution Cable Terminal Block dimensioned drawing is provided in Figures 4 & 5, for the SDCTBA11C and SDCTBA22C respectively, to assist in mounting the accessory.

Figure 4. Dimensioned drawing of the Distribution Cable Terminal Block 11C (dimensions shown in inches).

Figure 5. Dimensioned drawing of the Distribution Cable Terminal Block 22C (dimensions shown in inches).

GEH-706 Installation Instructions

Figure 6 shows a point-to-point wiring diagram for a Distribution Cable Terminal

Block SDCTBA11C connected to a Spectra ® RMS Molded-Case Circuit Breaker with a

microEntelliGuard TM Trip Unit. Figure 7 shows a point-to-point wiring diagram for a Distribution

Cable Terminal Block SDCTBA22C connected to a Spectra ® RMS Molded-Case Circuit Breaker with a microEntelliGuard TM Trip Unit.

NOTE : Use Terminal Block SDCTBA11 (refer back to Figures 1 and 2) to connect the SDCTBA11C or SDCTBA22C to the Voltage Module if required.

Figure 6. Wiring connections to the Distribution Cable Terminal Block 11C.

GEH-706 Installation Instructions

Figure 7. Wiring connections to the Distribution Cable Terminal Block 22C.

GEH-706 Installation Instructions

Connections

The screw terminals on the Distribution Cable Terminal

Block are labeled by function for clarity. The terminal strip pocket will accommodate a spade lug or ring terminal with a tongue width up to 0.320 inches. The terminal screw size is 10-32. To make the connection, attach an appropriate spade lug or ring terminal to the wire, slip the fastener beneath the terminal screw and tighten.

The Distribution Cable Terminal Block contains a cable with a 20-pin plug connector. To connect the end of the

Distribution Cable Terminal Block to a Spectra ® RMS

Molded-Case Circuit Breaker with a microEntelliGuard TM

Trip Unit, insert the breaker cable plug into the terminal block connector until the interlocks latch into the notch and hold the plug in place (See Figure 8).

Figure 8. Side view of breaker cable-terminal block insertion and attachment.

Additional Information

Refer to these other user’s manuals for mpre details:

GEH-5934 MicroVersaTrip ® Plus and MicroVersaTrip ®

PM Trip Units in Spectra ® RMS Molded-

Case Circuit Breakers

GEH-700 Spectra ® G Breaker w/

microEntelliGuard™ Trip Unit

GEH-701 Spectra ® K Breaker w/

microEntelliGuard™ Trip Unit

GEH-702 microEntelliGuard™ Trip Unit Users Manual

DEH-41318 Universal Rating Plug

GEH-6250 Voltage Module

GEH-6251 Power Supply Plate

GEH-6252 Voltage Conditioner Plate

GEH-6253 Power Supply Assembly

GEH-6254 Voltage Conditioner Assembly

GEH-703 MET Battery Pack Adapter

GEH-704 MET Advanced Distribution Cable

Junction Box

DEH-006 Distribution Cable Junction Box

GEH-705 MET Distribution Cable Extension (20-pin)

GEH-6256 Distribution Cable Extension (12-pin)

GEH-6255 Distribution Cable Harness (12-pin)

GEH-6257 Distribution Cable Terminal Block (11 point)

GEH-6491 POWER LEADER™ Modbus Concentrator

GEH-6502 POWER LEADER™ PMCS 5.0 Network

Architecture Guide

GEH-707 MET Sealable Cover kits

DEH-4568 GTU digital test kit (GTUTK20)

GEH-5551 Shunt Trip and UVR instructions

GEH-5593 Aux switch and bell alarm

GEK-64467 TIM-1 Zone Selective Interlock Module

Spectra and MicroVersaTrip are registered trademarks and EntelliGuard and

microEntelliGuard are trademarks of the General Electric Company.

These instructions do not cover all details or variations in equipment nor do they provide for every possible contingency that may be met in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise that are not covered sufficiently for the purchaser’s purposes, the matter should be referred to the GE Company.

GE Energy

41 Woodford Avenue, Plainville, CT 06062 www.geelectrical.com

© 2012 General Electric Company

imagination at work

GEH-706 Rev. 3 (10/12 M45)

advertisement