Linda Z.
What does error code KMC-522506-11 mean?
This error code indicates a general malfunction in the control unit. More specific details are unavailable.
Krone Messages - Parameters is a powerful tool that gives you the ability to view and manage error messages on your Krone machine. With Krone Messages - Parameters, you can quickly and easily identify the source of an error, view detailed information about the error, and take steps to resolve the issue.
Krone Messages - Parameters is an essential tool for any Krone machine owner or operator. It can help you to keep your machine running smoothly and avoid costly downtime.
Advertisement
Advertisement
Document number: 150001621_00_en
Version: 25/04/2022
2 Supplement to operating instructions 150001621_00_en
1
Validity
1.1
Information on this document
This document is valid for:
You can request a replacement document if this document became completely or partly unusable, or if you need it in a different language. Please specify the document number shown on the cover page in your order. Alternatively, you can download the document online from
KRONE MEDIA https://media.mykrone.green
.
To ensure that the machine is used safely and as intended, observe the following further applicable documents.
• Operating instructions of the respective machine
Supplement to operating instructions 150001621_00_en 3
2.1
2
Meaning of the supplement to the operating instructions
Safety
Risk of injury due to non-observance of relevant safety instructions
If the relevant safety instructions are not observed, persons may be seriously injured or killed.
In order to avoid accidents, the relevant safety instructions in the operating instructions must be read and observed.
Risk of injury due to non-observance of safety routines
If the relevant safety routines are not observed, persons may be seriously injured or killed.
In order to avoid accidents, the safety routines in the operating instructions must be read and observed.
Depending on the machine type, the basic safety instructions can be found in the chapter
“Safety”, “Basic Safety Instructions” or in the chapter “Safety” of the machine operating instructions.
The supplement to the operating instructions is an important document and a part of the machine. It is aimed at the user and contains safety-relevant information.
If the supplement to the operating instructions is not observed, people may be seriously injured or killed.
Read in full and observe the “Safety” chapter of the corresponding operating instructions
before using the machine for the first time, see Page 3 .
Before working, also read and observe the respective sections of the corresponding operating instructions,
Keep the supplement to the operating instructions ready to hand for the user of the machine.
Hand over the supplement to the operating instructions to subsequent users.
4 Supplement to operating instructions 150001621_00_en
3
Error messages
Risk of injury to persons and damage to machines if error messages are ignored
If error messages are ignored and the fault is not rectified, there is a risk of injury to persons and/or severe damage to the machine.
Eliminate the disturbance when an error message is displayed,
If the fault cannot be rectified, contact KRONE service partner.
CAN1
EQG000-034
The display shows an error message when a disturbance occurs on the machine. At the same
time, an audible signal sounds (continuous horn signal). For a list of the error messages, see
The error message is configured according to the following sample: e.g. error message
"520192-19 CAN1 "
520192 19
SPN (Suspect Parameter
Number) = error number
CAN1
Icon
Note down the error message.
Briefly press on .
Æ The acoustic signal stops and the error display is no longer indicated. The error message is displayed again if the fault occurs again.
Rectify the error,
Acknowledged and still pending error messages can be displayed again via the "Error list" menu or the status line.
Supplement to operating instructions 150001621_00_en 5
3.1
Possible error types (FMI)
There are different types of errors which are shown under the term FMI (Failure Mode
Identification) with an appropriate code.
10
11
12
13
8
9
6
7
4
5
2
3
FMI
0
1
18
19
20
21
31
14
15
16
17
Meaning
The upper limit value was greatly exceeded.
The lower limit value was far below the required one.
The data is not permitted.
There is an overvoltage or a short circuit to supply voltage.
There is an undervoltage or a short circuit to ground.
A cable is broken or amperage is too low.
There is a short circuit to ground or amperage is too low.
The mechanics do not respond or the expected result was not achieved.
The frequency is not permitted.
There is an abnormal update rate.
There is an abnormal rate of change.
The error cause is unknown.
There is an internal error.
The values of the calibration are outside the value range.
Particular instructions are required.
The upper limit value has been reached.
The upper limit value has been exceeded.
The lower limit value has been reached.
The lower limit value has not been reached.
There is a CAN communication failure.
The data deviates upwards.
The data deviates downwards.
The condition has been fulfilled.
Abbreviation
KMC
Explanation
KRONE Machine Controller
>>>
2
D2515020139100101_en-gb [ } 7]
6 Supplement to operating instructions 150001621_00_en
Software version: D2515020143000101_900,
D2515020139300101_900
Control unit: KMC
Page 1
Error number
KMC-520192-19
Error text
CAN1 - CAN disturbance between control units
KMC-520193-19 CAN2 - CAN disturbance between control units
KMC-520194-19 CAN3 - CAN disturbance between control units
KMC-520195-19 CAN4 - CAN disturbance between control units
KMC-520198-12 Control unit - Internal Error
KMC-520232-12
KMC-520234-31
KMC-521100-3
KMC-521100-4
KMC-521100-5
KMC-521100-6
KMC-521101-3
KMC-521101-4
KMC-521101-5
KMC-521101-6
KMC-521102-3
Vehicle identification number -
Internal Error
System check with KMC failed
Voltage group UB1 - Overvoltage
Voltage group UB1 - Undervoltage
Voltage group UB1 - Ground fault
Voltage group UB1 - Overload
Voltage group UB2 - Overvoltage
Voltage group UB2 - Undervoltage
Voltage group UB2 - Ground fault
Voltage group UB2 - Overload
Voltage group UB3 - Overvoltage
Description
There is a CAN disturbance between control units on CAN 1.
Figure
There is a CAN disturbance between control units on CAN 2.
There is a CAN disturbance between control units on CAN 3.
There is a CAN disturbance between control units on CAN 4.
An internal error in the control unit which was actuated by defective software or hardware.
Vehicle identification number has not been initialised.
With the KMC the cross-controller adjustment of system-relevant machine data has failed.
The input voltage of the corresponding voltage group is too high.
The input voltage of the corresponding voltage group is too low.
A ground fault has occurred on the supply voltage.
The maximum load on the supply voltage has been exceeded.
The input voltage of the corresponding voltage group is too high.
The input voltage of the corresponding voltage group is too low.
The maximum load on the supply voltage has been exceeded.
The maximum load on the supply voltage has been exceeded.
The input voltage of the corresponding voltage group is too high.
Page 2
Error number
KMC-521102-4
KMC-521102-5
KMC-521102-6
KMC-521103-3
Error text
Voltage group UB3 - Undervoltage
Voltage group UB3 - Ground fault
Voltage group UB3 - Overload
Voltage group UB4 - Overvoltage
KMC-521103-4 Voltage group UB4 - Undervoltage
KMC-521103-5
KMC-521103-6
KMC-521104-3
KMC-521104-4
KMC-521104-5
KMC-521104-6
KMC-521105-3
KMC-521105-4
KMC-521105-5
KMC-521105-6
KMC-521106-11
Voltage group UB4 - Ground fault
Voltage group UB4 - Overload
Voltage group UB5 - Overvoltage
Voltage group UB5 - Undervoltage
Voltage group UB5 - Ground fault
Voltage group UB5 - Overload
Voltage group UB6 - Overvoltage
Voltage group UB6 - Undervoltage
Voltage group UB6 - Ground fault
Voltage group UB6 - Overload
Supply voltage sensors - General disturbance
Description
The input voltage of the corresponding voltage group is too low.
Figure
A ground fault has occurred on the supply voltage.
The maximum load on the supply voltage has been exceeded.
The input voltage of the corresponding voltage group is too high.
The input voltage of the corresponding voltage group is too low.
A ground fault has occurred on the supply voltage.
The maximum load on the supply voltage has been exceeded.
The input voltage of the corresponding voltage group is too high.
The input voltage of the corresponding voltage group is too low.
A ground fault has occurred on the supply voltage.
The maximum load on the supply voltage has been exceeded.
The input voltage of the corresponding voltage group is too high.
The input voltage of the corresponding voltage group is too low.
A ground fault has occurred on the supply voltage.
The maximum load on the supply voltage has been exceeded.
The voltage has been switched off due to an overload or a short circuit on the supply voltage of the sensors.
Page 3
Error number
KMC-521107-3
KMC-521107-4
KMC-521108-11
KMC-521109-11
KMC-521110-11
KMC-521111-11
KMC-521112-11
Error text
Supply voltage - Overvoltage
Supply voltage - Undervoltage
Control unit - General disturbance
Control unit - General disturbance
Control unit - General disturbance
Control unit - General disturbance
Control unit - General disturbance
Description
The power supply on the UE connection is too high.
The power supply on the UE connection is too low.
The voltage group relay UB1 has not passed the self-test.
Figure
The voltage group relay UB2 has not passed the self-test.
The voltage group relay UB3 has not passed the self-test.
The voltage group relay UB4 has not passed the self-test.
The voltage group relay UB5 has not passed the self-test.
KMC-521113-11
KMC-521114-11
KMC-521115-11
KMC-521116-11
KMC-521117-11
KMC-521320-2
Control unit - General disturbance
Sensor supply voltage Uext1 -
General disturbance
Sensor supply voltage Uext2 -
General disturbance
Sensor supply voltage Uext3 -
General disturbance
Sensor supply voltage Uext4 -
General disturbance
Machine configuration - Logic error electronics
The voltage group relay UB6 has not passed the self-test.
The voltage group Uext1 for supplying the sensors is defective, for example due to overload or short circuit.
The voltage group Uext2 for supplying the sensors is defective, for example due to overload or short circuit.
The voltage group Uext3 for supplying the sensors is defective, for example due to overload or short circuit.
The voltage group Uext4 for supplying the sensors is defective, for example due to overload or short circuit.
Configuration of the machine is not compatible with the hardware.
KMC-521350-11 Control unit - General disturbance
KMC-521351-11 Control unit - General disturbance
KMC-520198-12 Internal Error Internal error in the control unit caused by defective software or hardware.
Page 4
Error number
KMC-522002-7
Error text
Logic fault mechanics
KMC-522003-7 Logic fault mechanics
KMC-522004-7 Logic fault mechanics
KMC-522005-7 Logic fault mechanics
KMC-522006-3 Valve Q6 - Cable break or short circuit to UB
KMC-522006-6 Valve Q6 - Short circuit to ground
KMC-522006-7 Logic fault mechanics
KMC-522008-7 Logic fault mechanics
KMC-522009-7 Logic fault mechanics
KMC-522010-7 Logic fault mechanics
KMC-522011-7 Logic fault mechanics
Description
KMC-522012-7 Logic fault mechanics
KMC-522013-7 Switch/momentary switch S4 - Logic fault mechanics
KMC-522014-7 Logic fault mechanics
KMC-522021-7 Logic fault mechanics
KMC-522022-7 Logic fault mechanics
Figure
Page 5
Error number
KMC-522023-7
Error text
Logic fault mechanics
KMC-522024-7 Logic fault mechanics
KMC-522025-7 Logic fault mechanics
KMC-522026-7 Logic fault mechanics
KMC-522027-7 Logic fault mechanics
KMC-522028-7 Logic fault mechanics
KMC-522029-7 Position wrapping arm - Logic fault mechanics
KMC-522030-7
KMC-522031-7
Position wrapping table - Logic fault mechanics
Logic fault mechanics
Description
KMC-522032-7 Valve Q10 - Logic fault mechanics
KMC-522033-7 Valve Q10 - Logic fault mechanics
KMC-522034-7 Logic fault mechanics
KMC-522035-7
KMC-522036-7
KMC-522037-7
KMC-522038-7
Sensor
- B16 Wheel speed on left
- B21
- Logic fault mechanics
Logic fault mechanics
Wrapping arm valve fault Valve Q2
Drive of wrapping arm - Logic fault mechanics
Valve Q14 - Logic fault mechanics
The speed of the wrapping arm deviates from the default.
The wrapping arm speed valve does not close correctly.
Figure
Page 6
Error number
KMC-522039-7
KMC-522040-7
Error text
Valve Q15 Move right holding and cutting device - Logic fault mechanics
Valve Q7 - Logic fault mechanics
Description
KMC-522041-7 Valve Q16 Move wrapping table -
Logic fault mechanics
KMC-522042-7
KMC-522043-7
Valve Q17 Move bale turner - Logic fault mechanics
Valve Q10 - Logic fault mechanics
KMC-522044-7 Logic fault mechanics
KMC-522045-7 Valve Q8 - Logic fault mechanics
KMC-522101-3
KMC-522101-4
KMC-522102-3
KMC-522102-4
Sensor A70.B240 Position wrapping arm - Short circuit to UB
Sensor A70.B240 Position wrapping arm - Cable break or short circuit to ground
Sensor B2 Bale in pick-up position -
Cable break
Sensor B2 Bale in pick-up position -
Short circuit to ground or UB
KMC-522104-3 Sensor B4 - Cable break
KMC-522104-4 Sensor B4 - Short circuit to ground or UB
KMC-522106-3 Sensor B6 - Cable break
KMC-522106-4 Sensor B6 - Short circuit to ground or UB
KMC-522107-3 Sensor A70.B225 Film tear detection
1 - Cable break
Figure
Page 7
Error number
KMC-522107-4
Error text
Sensor A70.B225 Film tear detection
1 - Short circuit to ground or UB
Description
KMC-522108-3
KMC-522108-4
Sensor A70.B226 Film tear detection
2 - Cable break
Sensor A70.B226 Film tear detection
2 - Short circuit to ground or UB
KMC-522109-3
KMC-522109-4
Sensor B9 Bale detection wrapping table - Cable break
Sensor B9 Bale detection wrapping table - Short circuit to ground or UB
KMC-522110-3
KMC-522110-4
KMC-522111-3
Sensor B10 Position wrapping table -
Short circuit to UB
Sensor B10 Position wrapping table -
Cable break or short circuit to ground
Sensor B11 - Cable break
KMC-522111-4
KMC-522112-3
Sensor B11 - Short circuit to ground or UB
Sensor B12 - Short circuit to UB
KMC-522112-4
KMC-522113-3
Sensor B12 - Cable break or short circuit to ground
Sensor B13 - Cable break
KMC-522113-4
KMC-522116-3
KMC-522116-4
KMC-522118-3
Sensor B13 - Short circuit to ground or UB
Sensor B16 Wheel speed on left -
Cable break
Sensor B16 Wheel speed on left -
Short circuit to ground or UB
Sensor B19 - Cable break
Figure
Page 8
Error number
KMC-522118-4
Error text
Sensor B19 - Short circuit to ground or UB
Description
KMC-522120-3 Sensor B20 - Short circuit to UB
KMC-522120-4 Sensor B20 - Cable break or short circuit to ground
KMC-522121-3 Sensor B21 - Cable break
KMC-522121-4 Sensor B21 - Short circuit to ground or UB
KMC-522130-22 Cable break or short circuit to ground
KMC-522130-23 Cable break, short circuit to earth or short circuit to UB
KMC-522151-4
KMC-522151-24
KMC-522153-4
Switch/momentary switch
- A70.S201
- A70.S202
- Short circuit to ground or UB
Switch/momentary switch
- A70.S201
- A70.S202
- Short circuit to earth or short circuit to UB
Switch/momentary switch S3 Quickstop switch - Short circuit to ground
KMC-522153-22
KMC-522154-3
Switch/momentary switch S3 Quickstop switch - Cable break or short circuit to ground
Switch/momentary switch S4 -
Cable break or short circuit to UB
KMC-522154-4
KMC-522155-3
Switch/momentary switch S4 - Short circuit to ground
Switch/momentary switch S5 -
Cable break or short circuit to UB
KMC-522155-4 Switch/momentary switch S5 - Short circuit to ground
KMC-522250-16 Upper limit value exceeded
Figure
Page 9
Error number
KMC-522250-18
Error text
Lower limit value below minimum
Description
KMC-522251-16 Upper limit value exceeded
KMC-522251-18 Lower limit value below minimum
KMC-522301-3
KMC-522301-6
Valve Q1 Load Sensing active - Cable break or short circuit to UB
Valve Q1 Load Sensing active - Short circuit to ground
KMC-522302-3
KMC-522302-6
Valve Q2 Drive of wrapping arm -
Cable break or short circuit to UB
Valve Q2 Drive of wrapping arm -
Short circuit to ground
KMC-522303-3
KMC-522303-6
Valve Q3 - Cable break or short circuit to UB
Valve Q3 - Short circuit to ground
KMC-522304-3
KMC-522304-6
Valve Q4 Pressure supply valve -
Cable break or short circuit to UB
Valve Q4 Pressure supply valve -
Short circuit to ground
KMC-522305-3
KMC-522305-6
Valve Q5 - Cable break or short circuit to UB
Valve Q5 - Short circuit to ground
KMC-522307-3
KMC-522307-6
Valve Q7 - Cable break or short circuit to UB
Valve Q7 - Short circuit to ground
KMC-522308-3 Valve Q8 - Cable break or short circuit to UB
Figure
Error number
KMC-522308-6
Error text
Valve Q8 - Short circuit to ground
Description
KMC-522309-3
KMC-522309-6
Valve Q9 Reverse wrapping arm -
Cable break or short circuit to UB
Valve Q9 Reverse wrapping arm -
Short circuit to ground
KMC-522310-3
KMC-522310-6
Valve Q10 - Cable break or short circuit to UB
Valve Q10 - Short circuit to ground
KMC-522311-3
KMC-522311-6
Valve Q11 - Cable break or short circuit to UB
Valve Q11 - Short circuit to ground
KMC-522311-6 Valve Q13 - Short circuit to ground
KMC-522312-3 Valve Q12 - Cable break or short circuit to UB
KMC-522313-3
KMC-522313-6
Valve Q13 - Cable break or short circuit to UB
Valve Q12 - Short circuit to ground
KMC-522314-3
KMC-522314-6
Valve Q14 - Cable break or short circuit to UB
Valve Q14 - Short circuit to ground
KMC-522315-3
KMC-522315-6
KMC-522316-3
Valve Q15 Move right holding and cutting device - Cable break or short circuit to UB
Valve Q15 Move right holding and cutting device - Short circuit to ground
Valve Q16 Move wrapping table -
Cable break or short circuit to UB
Page 10
Figure
Error number
KMC-522316-6
Error text
Valve Q16 Move wrapping table -
Short circuit to ground
Description
KMC-522317-3
KMC-522317-6
Valve Q17 Move bale turner - Cable break or short circuit to UB
The "move bale turner" actuator signals a cable break.
Valve Q17 Move bale turner - Short circuit to ground
The "move bale turner" actuator signals a short circuit
KMC-522351-3
KMC-522351-6
KMC-522352-6 lamp
- E1 Working lights 1
- E2 Working lights 2
- Cable break or short circuit to UB lamp
- E1 Working lights 1
- E2 Working lights 2
- Short circuit to ground lamp E7 - Short circuit to ground
KMC-522355-5
KMC-522500-13 The wrong configuration values were saved
Figure
KMC-522503-31
KMC-522504-31
KMC-522505-31
KMC-522506-31
KMC-522560-19 FMA 1 - Malfunction
KMC-522561-4 FMA 1 - Undervoltage
KMC-522562-12 FMA 1 - Internal Error
KMC-522563-3 FMA 1 - Overvoltage
Page 11
Error number
KMC-522650-3
Error text
Overvoltage
KMC-522650-4 Undervoltage
KMC-522650-12 Internal Error
KMC-522650-19
Description Figure
Page 12
4 Index
A
Acknowledging error message ............................. 5
Applicable documents .......................................... 3
E
Error list ................................................................ 6
Error messages .................................................... 5
I
Information on this document ............................... 3
M
Meaning of the supplement to the operating
instructions ........................................................... 4
P
Possible error types (FMI) .................................... 6
R
Re-ordering .......................................................... 3
S
Safety ................................................................... 4
V
Validity .................................................................. 3
20 Supplement to operating instructions 150001621_00_en
This page has been left blank deliberately.
Supplement to operating instructions 150001621_00_en 21
* Heinrich-Krone-Straße 10
D-48480 Spelle
* Postfach 11 63
D-48478 Spelle
' +49 (0) 59 77 / 935-0
6 +49 (0) 59 77 / 935-339
www.landmaschinen.krone.de
Advertisement
View error messages in real time
Get detailed information about each error
Clear error messages
Export error messages to a file
Print error messages
To use Krone Messages - Parameters, simply connect it to your Krone machine. The software will automatically detect your machine and display any error messages that are present.
Krone Messages - Parameters can display any type of error message that is generated by your Krone machine.
To clear an error message, simply click on the "Clear" button. The error message will be cleared and the machine will be reset.
What does error code KMC-522506-11 mean?
This error code indicates a general malfunction in the control unit. More specific details are unavailable.
Login to continue