Krone EzBA RP Operating Instructions
Реклама
Реклама
Enclose this document with the operating instructions of the machine.
Supplement to operating instructions
Document number: 150001622_00_en
Version: 10/08/2021
Round baler
Software version: D2515020105300029
Error messages and parameters
Table of contents
2
Round baler
Supplement to operating instructions 150001622_00_en
1
1.1
1.2
1.3
Information on this document
Validity
1
1.1
Information on this document
Validity
This document is valid for:
RP801-35 (Comprima CV 150 XC Plus)
RP801-31 (Comprima V 150 XC Plus)
RP701-41 (Comprima V 180 XC)
RP701-35 (Comprima CV 150 XC)
RP701-30 (Comprima V 150)
RP701-21 (Comprima F 155 XC)
RP701-11 (Comprima F 125 XC)
RP601-31 (Fortima V 1500 MC)
RP601-30 (Fortima V 1500)
RP601-20 (Fortima F 1600)
RP301-21 (VariPack V 190 XC Plus)
RP301-20 (VariPack V 190 Plus)
RP201-20 (VariPack V 190)
RP601-10 (Fortima F 1250)
RP801-21 (Comprima F 155 XC Plus)
RP201-10 (VariPack V 165)
RP801-25 (Comprima CF 155 XC Plus)
RP701-51 (Comprima V 210 XC)
RP701-40 (Comprima V 180)
RP701-31 (Comprima V 150 XC)
RP701-25 (Comprima CF 155 XC)
RP701-20 (Comprima F 155)
RP601-41 (Fortima V 1800 MC)
RP601-40 (Fortima V 1800)
RP601-21 (Fortima F 1600 MC)
RP601-11 (Fortima F 1250 MC)
RP301-11 (VariPack V 165 XC Plus)
RP201-21 (VariPack V 190 XC)
RP201-11 (VariPack V 165 XC)
RP701-10 (Comprima F 125)
RP301-10 (VariPack V 165 Plus)
Re-ordering
You can request a replacement document if this document became completely or partly unusable, or if you need it in a different language. Please specify the document number shown on the cover page in your order. Alternatively, you can download the document online from
KRONE MEDIA https://media.krone.de
.
Applicable documents
To ensure that the machine is used safely and as intended, observe the following further applicable documents.
• Operating instructions of the respective machine
Round baler
Supplement to operating instructions 150001622_00_en 3
2
2.1
2
Safety
Meaning of the supplement to the operating instructions
Safety
WARNING
Risk of injury due to non-observance of relevant safety instructions
If the relevant safety instructions are not observed, persons may be seriously injured or killed.
In order to avoid accidents, the relevant safety instructions in the operating instructions must be read and observed.
WARNING
Risk of injury due to non-observance of safety routines
If the relevant safety routines are not observed, persons may be seriously injured or killed.
In order to avoid accidents, the safety routines in the operating instructions must be read and observed.
INFO
Depending on the machine type, the basic safety instructions can be found in the chapter
“Safety”, “Basic Safety Instructions” or in the chapter “Safety” of the machine operating instructions.
2.1
Meaning of the supplement to the operating instructions
The supplement to the operating instructions is an important document and a part of the machine. It is aimed at the user and contains safety-relevant information.
If the supplement to the operating instructions is not observed, people may be seriously injured or killed.
Read in full and observe the “Safety” chapter of the corresponding operating instructions
before using the machine for the first time, see Page 3 .
Before working, also read and observe the respective sections of the corresponding operating instructions,
Keep the supplement to the operating instructions ready to hand for the user of the machine.
Hand over the supplement to the operating instructions to subsequent users.
4
Round baler
Supplement to operating instructions 150001622_00_en
3
Error Messages 3
Error Messages
WARNING
Risk of injury to persons and damage to machines if error messages are ignored
If error messages are ignored and the fault is not rectified, there is a risk of injury to persons and/or severe damage to the machine.
Eliminate the disturbance when an error message is displayed,
If the fault cannot be rectified, contact KRONE service partner.
KMC - 521202- 5
B11
L
EQG000-034
The display shows an error message when a disturbance occurs on the machine. At the same
time, an audible signal sounds (continuous horn signal). For a list of the error messages, see
Configuration of an error message
The error message is configured according to the following sample: e.g. error message
"520192-19 CAN1 "
520192 19
CAN1
SPN (Suspect Parameter
Number) = error number
Icon
Acknowledging error message
Note down the error message.
Briefly press on .
Æ The acoustic signal stops and the error display is no longer indicated. If the fault occurs again, the error message will be displayed again.
To acknowledge the error message until the operating terminal is next started, press and hold down the key for 5 seconds.
Rectify the error,
Acknowledged and still pending error messages can be displayed again via the "Error list" menu or the status line.
Round baler
Supplement to operating instructions 150001622_00_en 5
3
3.1
3.1
Error Messages
Possible error types (FMI)
Possible error types (FMI)
There are different types of errors which are shown under the term FMI (Failure Mode
Identification) with an appropriate code.
10
11
12
13
8
9
6
7
4
5
2
3
FMI
0
1
18
19
20
21
31
14
15
16
17
Meaning
The upper limit value was greatly exceeded.
The lower limit value was far below the required one.
The data is not permitted.
There is an overvoltage or a short circuit to supply voltage.
There is an undervoltage or a short circuit to ground.
A cable is broken or amperage is too low.
There is a short circuit to ground or amperage is too low.
The mechanics do not respond or the expected result was not achieved.
The frequency is not permitted.
There is an abnormal update rate.
There is an abnormal rate of change.
The error cause is unknown.
There is an internal error.
The values of the calibration are outside the value range.
Particular instructions are required.
The upper limit value has been reached.
The upper limit value has been exceeded.
The lower limit value has been reached.
The lower limit value has not been reached.
There is a CAN communication failure.
The data deviates upwards.
The data deviates downwards.
The condition has been fulfilled.
3.2
Error list
>>>
2
Fehlerliste_D2515020105300029_en [ } 7]
6
Round baler
Supplement to operating instructions 150001622_00_en
Error list
Software version: D2515020105400029_200
Control unit: KMC
Page 1
Error number
KMC-520192-19
Error text
CAN1 - CAN disturbance between control units
KMC-520193-19 CAN2 - CAN disturbance between control units
KMC-520194-19 CAN3 - CAN disturbance between control units
KMC-520195-19 CAN4 - CAN disturbance between control units
KMC-520198-12 Control unit - Internal Error
KMC-520232-12
KMC-520234-31
KMC-521100-3
KMC-521100-4
KMC-521100-5
KMC-521100-6
KMC-521101-3
KMC-521101-4
KMC-521101-5
KMC-521101-6
KMC-521102-3
Vehicle identification number -
Internal Error
System check with KMC failed
Voltage group UB1 - Overvoltage
Voltage group UB1 - Undervoltage
Voltage group UB1 - Ground fault
Voltage group UB1 - Overload
Voltage group UB2 - Overvoltage
Voltage group UB2 - Undervoltage
Voltage group UB2 - Ground fault
Voltage group UB2 - Overload
Voltage group UB3 - Overvoltage
Description
There is a CAN disturbance between control units on CAN 1.
Figure
There is a CAN disturbance between control units on CAN 2.
There is a CAN disturbance between control units on CAN 3.
There is a CAN disturbance between control units on CAN 4.
An internal error in the control unit which was actuated by defective software or hardware.
Vehicle identification number has not been initialised.
With the KMC the cross-controller adjustment of system-relevant machine data has failed.
The input voltage of the corresponding voltage group is too high.
The input voltage of the corresponding voltage group is too low.
A ground fault has occurred on the supply voltage.
The maximum load on the supply voltage has been exceeded.
The input voltage of the corresponding voltage group is too high.
The input voltage of the corresponding voltage group is too low.
The maximum load on the supply voltage has been exceeded.
The maximum load on the supply voltage has been exceeded.
The input voltage of the corresponding voltage group is too high.
Page 2
Error number
KMC-521102-4
KMC-521102-5
KMC-521102-6
KMC-521103-3
Error text
Voltage group UB3 - Undervoltage
Voltage group UB3 - Ground fault
Voltage group UB3 - Overload
Voltage group UB4 - Overvoltage
KMC-521103-4 Voltage group UB4 - Undervoltage
KMC-521103-5
KMC-521103-6
KMC-521104-3
KMC-521104-4
KMC-521104-5
KMC-521104-6
KMC-521105-3
KMC-521105-4
KMC-521105-5
KMC-521105-6
KMC-521106-11
Voltage group UB4 - Ground fault
Voltage group UB4 - Overload
Voltage group UB5 - Overvoltage
Voltage group UB5 - Undervoltage
Voltage group UB5 - Ground fault
Voltage group UB5 - Overload
Voltage group UB6 - Overvoltage
Voltage group UB6 - Undervoltage
Voltage group UB6 - Ground fault
Voltage group UB6 - Overload
Supply voltage sensors - General disturbance
Description
The input voltage of the corresponding voltage group is too low.
Figure
A ground fault has occurred on the supply voltage.
The maximum load on the supply voltage has been exceeded.
The input voltage of the corresponding voltage group is too high.
The input voltage of the corresponding voltage group is too low.
A ground fault has occurred on the supply voltage.
The maximum load on the supply voltage has been exceeded.
The input voltage of the corresponding voltage group is too high.
The input voltage of the corresponding voltage group is too low.
A ground fault has occurred on the supply voltage.
The maximum load on the supply voltage has been exceeded.
The input voltage of the corresponding voltage group is too high.
The input voltage of the corresponding voltage group is too low.
A ground fault has occurred on the supply voltage.
The maximum load on the supply voltage has been exceeded.
The voltage has been switched off due to an overload or a short circuit on the supply voltage of the sensors.
Page 3
Error number
KMC-521107-3
KMC-521107-4
KMC-521108-11
KMC-521109-11
KMC-521110-11
KMC-521111-11
KMC-521112-11
Error text
Supply voltage - Overvoltage
Supply voltage - Undervoltage
Control unit - General disturbance
Control unit - General disturbance
Control unit - General disturbance
Control unit - General disturbance
Control unit - General disturbance
Description
The power supply on the UE connection is too high.
The power supply on the UE connection is too low.
The voltage group relay UB1 has not passed the self-test.
Figure
The voltage group relay UB2 has not passed the self-test.
The voltage group relay UB3 has not passed the self-test.
The voltage group relay UB4 has not passed the self-test.
The voltage group relay UB5 has not passed the self-test.
KMC-521113-11 Control unit - General disturbance The voltage group relay UB6 has not passed the self-test.
KMC-521114-11
KMC-521115-11
KMC-521116-11
KMC-521117-11
KMC-521118-11
KMC-521320-2
Sensor supply voltage U1 - General disturbance
Sensor supply voltage U2 - General disturbance
Sensor supply voltage U3 - General disturbance
Sensor supply voltage U4 - General disturbance
Voltage group relay UB2 - General disturbance
Machine configuration - Logic error electronics
The voltage group Uext1 for supplying the sensors is defective, for example due to overload or short circuit.
The voltage group Uext2 for supplying the sensors is defective, for example due to overload or short circuit.
The voltage group Uext3 for supplying the sensors is defective, for example due to overload or short circuit.
The voltage group Uext4 for supplying the sensors is defective, for example due to overload or short circuit.
Platform fault for BiG X only: A disturbance was detected at the intake/header (broken cable/short circuit to one of the valves Q55 - Q58 or a broken cable/short circuit from relay Q72). The voltage group relay
UB2 was therefore switched off.
Configuration of the machine is not compatible with the hardware.
KMC-521350-11 Control unit - General disturbance
Page 4
Error number
KMC-521351-11
Error text
Control unit - General disturbance
Description
KMC-522000-7
KMC-522001-7
KMC-522005-2
Quick-stop switch - Logic fault mechanics
The quick-stop switch has been activated.
Quick-stop retaining bracket - Logic fault mechanics
The quick-stop retaining bracket has been activated.
universal shaft - Logic error electronics
KMC-522005-16 universal shaft - Upper limit value exceeded
The universal shaft rotates and the operating status is road mode.
The universal shaft is rotating faster than permitted.
KMC-522010-7
KMC-522011-7
Blade cassette movement prompt -
Logic fault mechanics
The blade cassette must be lifted.
Blade cassette movement prompt -
Logic fault mechanics
The blade cassette must be lowered.
KMC-522012-7
KMC-522014-7
Blade cassette not up - Logic fault mechanics
The blade cassette is not up.
Blade cassette movement prompt -
Logic fault mechanics
The blade cassette must be pressurised.
KMC-522015-7 Blade cassette Timeout - Logic fault mechanics
Movement of the blade cassette has a timeout.
KMC-522020-7
KMC-522021-7
KMC-522022-7
KMC-522023-18
KMC-522024-7
Tying net not pulled - Logic fault mechanics
Tying net stopped - Logic fault mechanics
Tying net is being pulled - Logic fault mechanics
Feed roller below minimum speed -
Lower limit value below minimum
Tying net not cut off - Logic fault mechanics
The wrapping and tying material was not received by/pulled from the bale when tying is activated.
The wrapping and tying material stops after a certain time when tying is activated.
The wrapping and tying material is being pulled from the bale even though tying has not started.
The feed roller is below the minimum speed when the wrapping and tying material is pulled.
The wrapping and tying material has not been cut off.
KMC-522025-7 Tying net not pulled - Logic fault mechanics
The wrapping and tying material was not received by/pulled from the bale when tying is activated.
Figure
Page 5
Error number
KMC-522026-7
KMC-522027-7
KMC-522028-7
Error text
Tying net stopped - Logic fault mechanics
Tying net is being pulled - Logic fault mechanics
Tying net not cut off - Logic fault mechanics
Description
The wrapping and tying material stops after a certain time when tying is activated.
The wrapping and tying material is being pulled from the bale even though tying has not started.
The wrapping and tying material has not been cut off.
Figure
KMC-522029-7
KMC-522030-7
KMC-522031-7
KMC-522033-7
Tying twine not pulled - Logic fault mechanics
Tying twine stopped - Logic fault mechanics
Tying twine is being pulled - Logic fault mechanics
KMC-522032-18 Feed roller below minimum speed -
Lower limit value below minimum
Tying twine not cut off - Logic fault mechanics
The wrapping and tying material was not received by/pulled from the bale when tying is activated.
The wrapping and tying material stops after a certain time when tying is activated.
The wrapping and tying material is being pulled from the bale even though tying has not started.
The feed roller is below the minimum speed when the wrapping and tying material is pulled.
The wrapping and tying material has not been cut off.
KMC-522034-7 Tying twine Timeout - Logic fault mechanics
KMC-522035-16 Maximum filling exceeded - Upper limit value exceeded
The twine arms could not be moved within the stipulated time into the required position.
The bale chamber has been filled above the maximum.
KMC-522038-18
KMC-522040-16
KMC-522041-16
KMC-522044-7
Slip of bale formation conveyor -
Lower limit value below minimum
Left bale conical - Upper limit value exceeded
Right bale conical - Upper limit value exceeded
Position of tailgate unclear - Logic fault mechanics
The setpoint speed of the bale formation conveyor of the bale chamber was below the minimum.
The filling between the left and right sides of the bale differs too much, too large on the left.
The filling between the left and right sides of the bale differs too much, too large on the right.
The position of the tailgate could not be determined.
KMC-522045-7 Open tailgate Timeout - Logic fault mechanics
The tailgate could not be opened within the stipulated time.
KMC-522046-7 Close tailgate Timeout - Logic fault mechanics
The tailgate could not be closed within the stipulated time.
Page 6
Error number
KMC-522048-7
Error text Description
Tailgate open - Logic fault mechanics The tailgate is open during road operating mode.
KMC-522049-7
KMC-522050-18
Tailgate open - Logic fault mechanics An open tailgate was detected, although no tying has occurred since it was last closed.
Rotational speed universal shaft -
Lower limit value below minimum
The PTO speed is too low.
KMC-522051-7
KMC-522052-7
Position of tailgate - Logic fault mechanics
Position of lifter - Logic fault mechanics
The position of the tailgate is not correct.
The position of the lifter is not correct.
Figure
KMC-522053-7
KMC-522054-7
Position wrapping table - Logic fault mechanics
The position of the wrapping table is not correct.
Position wrapping arm - Logic fault mechanics
The position of the wrapping arm is not correct.
KMC-522055-7
KMC-522056-7
Position of holding arms - Logic fault mechanics
The position of the holding arm is not correct.
Transfer Timeout - Logic fault mechanics
The transfer has a timeout.
KMC-522057-7 Bale on lifter - Logic fault mechanics The bale is not on the lifter.
KMC-522058-7 Bale on wrapping table - Logic fault mechanics
There is a bale on the wrapping table.
KMC-522060-7
KMC-522066-7
KMC-522070-7
KMC-522075-7
Tailgate automatic system Timeout -
Logic fault mechanics
The tailgate automatic system has a
Timeout
Lifter Timeout - Logic fault mechanics The lifter of the bale transfer could not be moved within the stipulated time into the required position.
Wrapping table Timeout - Logic fault mechanics
Film tear on one side - Logic fault mechanics
The wrapping table could not be moved within the stipulated time into the required position.
The film is torn on one side.
KMC-522076-7 Film tear on both sides - Logic fault mechanics
The film is torn on both sides.
Page 7
Error number
KMC-522078-16
KMC-522079-18
KMC-522080-7
KMC-522081-7
KMC-522082-7
KMC-522083-7
Error text
Moisture measurement - Upper limit value exceeded
Moisture measurement - Lower limit value below minimum
Tying film not pulled - Logic fault mechanics
Tying film stopped - Logic fault mechanics
Tying film is being pulled - Logic fault mechanics
Tying film not cut off - Logic fault mechanics
Description
The upper moisture limit value was below the minimum during the moisture measurement.
The lower moisture limit value was below the minimum during the moisture measurement.
The wrapping and tying material was not received by/pulled from the bale when tying is activated.
The wrapping and tying material stops after a certain time when tying is activated.
The wrapping and tying material is being pulled from the bale even though tying has not started.
The wrapping and tying material has not been cut off.
Figure
KMC-522084-7
KMC-522085-7
KMC-522086-7
KMC-522087-7
Tying twine not pulled - Logic fault mechanics
Tying twine stopped - Logic fault mechanics
Tying twine is being pulled - Logic fault mechanics
Tying twine not cut off - Logic fault mechanics
The wrapping and tying material was not received by/pulled from the bale when tying is activated.
The wrapping and tying material stops after a certain time when tying is activated.
The wrapping and tying material is being pulled from the bale even though tying has not started.
The wrapping and tying material has not been cut off.
KMC-522088-7
KMC-522089-7
KMC-522091-18
Tying net Timeout movement - Logic fault mechanics
Tying film Timeout movement - Logic fault mechanics
Baling pressure below minimum -
Lower limit value below minimum
The rocker arm could not be moved to the required position within the specified time
The rocker arm could not be moved to the required position within the specified time.
The baling pressure is below the minimum required value
KMC-522093-7
KMC-522094-7
Position of tailgate Combi unclear -
Logic fault mechanics
The position of the tailgate could not be determined.
Open tailgate Combi Timeout - Logic fault mechanics
The tailgate could not be opened within the stipulated time.
KMC-522095-7 Close tailgate Combi Timeout - Logic fault mechanics
The tailgate could not be closed within the stipulated time.
Page 8
Error number
KMC-522097-7
KMC-522098-7
KMC-522101-3
Error text
Tailgate Combi open - Logic fault mechanics
Description
The tailgate is open during road operating mode.
Tailgate Combi open - Logic fault mechanics
Sensor B01 Speed of bale chamber -
Cable break
An open tailgate was detected, although no tying has occurred since it was last closed.
Figure
KMC-522101-4
KMC-522102-3
Sensor B01 Speed of bale chamber -
Short circuit to ground or UB
Sensor B02 Tying process active -
Cable break
KMC-522102-4
KMC-522103-3
Sensor B02 Tying process active -
Short circuit to ground or UB
Sensor B74 Acceleration wrapping table - Cable break
KMC-522103-4
KMC-522105-3
Sensor B74 Acceleration wrapping table - Short circuit to ground or UB
Sensor B05 Slip of bale formation conveyor - Cable break
KMC-522105-4
KMC-522106-3
Sensor B05 Slip of bale formation conveyor - Short circuit to ground or
UB
Sensor B06 Tying process active 1 twine tying - Cable break
KMC-522106-4
KMC-522107-3
Sensor B06 Tying process active 1 twine tying - Short circuit to ground or UB
Sensor B07 Tying process active 2 twine tying - Cable break
KMC-522107-4
KMC-522108-3
Sensor B07 Tying process active 2 twine tying - Short circuit to ground or UB
Sensor B08 Bale chute top - Cable break
KMC-522108-4 Sensor B08 Bale chute top - Short circuit to ground or UB
Page 9
Error number
KMC-522109-3
Error text
Sensor B09 Filling display on left -
Short circuit to UB
Description
KMC-522109-4
KMC-522110-3
Sensor B09 Filling display on left -
Cable break or short circuit to ground
Sensor B10 Filling display on right -
Short circuit to UB
KMC-522110-4
KMC-522111-3
KMC-522111-4
KMC-522112-3
KMC-522112-4
KMC-522113-3
Sensor B10 Filling display on right -
Cable break or short circuit to ground
Sensor B11 Lock hook bale chamber on left - Cable break
Sensor B11 Lock hook bale chamber on left - Short circuit to ground or UB
Sensor B12 Lock hook bale chamber on right - Cable break
Sensor B12 Lock hook bale chamber on right - Short circuit to ground or
UB
Sensor B13 Position of twine guide slide - Cable break
KMC-522113-4
KMC-522114-3
KMC-522114-4
KMC-522115-3
Sensor B13 Position of twine guide slide - Short circuit to ground or UB
Sensor B14 Bale chamber open -
Cable break
Sensor B14 Bale chamber open -
Short circuit to ground or UB
Sensor B15 ejecting the bale - Cable break
KMC-522115-4
KMC-522120-3
Sensor B15 ejecting the bale - Short circuit to ground or UB
Sensor B20 Zero position wrapping arm - Cable break
KMC-522120-4 Sensor B20 Zero position wrapping arm - Short circuit to ground or UB
Figure
Error number
KMC-522121-3
Error text
Sensor B21 Position wrapping arm -
Cable break
Description
KMC-522121-4
KMC-522122-3
Sensor B21 Position wrapping arm -
Short circuit to ground or UB
Sensor B22 Left holding arm open -
Cable break
KMC-522122-4
KMC-522123-3
Sensor B22 Left holding arm open -
Short circuit to ground or UB
Sensor B23 Right holding arm open -
Cable break
KMC-522123-4
KMC-522124-3
Sensor B23 Right holding arm open -
Short circuit to ground or UB
Sensor B24 Film tear detection -
Cable break
KMC-522124-4
KMC-522126-3
Sensor B24 Film tear detection -
Short circuit to ground or UB
Sensor B26 Bale lifter down - Cable break
KMC-522126-4
KMC-522127-3
Sensor B26 Bale lifter down - Short circuit to ground or UB
Sensor B27 Position wrapping table -
Short circuit to UB
KMC-522127-4
KMC-522135-3
Sensor B27 Position wrapping table -
Cable break or short circuit to ground
Sensor B35 Left holding arm closed -
Cable break
KMC-522135-4
KMC-522136-3
Sensor B35 Left holding arm closed -
Short circuit to ground or UB
Sensor B36 Right holding arm closed
- Cable break
KMC-522136-4 Sensor B36 Right holding arm closed
- Short circuit to ground or UB
Page 10
Figure
Error number
KMC-522140-3
Error text
Sensor B40 Blade group B swivelled out - Cable break
Description
KMC-522140-4
KMC-522141-3
Sensor B40 Blade group B swivelled out - Short circuit to ground or UB
Sensor B41 Blade group B swivelled in - Cable break
KMC-522141-4
KMC-522142-3
Sensor B41 Blade group B swivelled in - Short circuit to ground or UB
Sensor B42 Blade group A swivelled out - Cable break
KMC-522142-4
KMC-522143-3
Sensor B42 Blade group A swivelled out - Short circuit to ground or UB
Sensor B43 Blade group A swivelled in - Cable break
KMC-522143-4
KMC-522146-3
Sensor B43 Blade group A swivelled in - Short circuit to ground or UB
Sensor B46 Blade control shaft 0 -
Cable break
KMC-522146-4
KMC-522147-3
Sensor B46 Blade control shaft 0 -
Short circuit to ground or UB
Sensor B47 Blade control shaft 1 -
Cable break
KMC-522147-4
KMC-522150-3
Sensor B47 Blade control shaft 1 -
Short circuit to ground or UB
Sensor B50 Bale detection wrapping table - Short circuit to UB
KMC-522150-4
KMC-522151-3
Sensor B50 Bale detection wrapping table - Cable break or short circuit to ground
Sensor B09 Filling display on left -
Short circuit to UB
KMC-522151-4 Sensor B09 Filling display on left -
Cable break or short circuit to ground
Page 11
Figure
Error number
KMC-522152-3
Error text
Sensor B10 Filling display on right -
Short circuit to UB
Description
KMC-522152-4
KMC-522161-3
Sensor B10 Filling display on right -
Cable break or short circuit to ground
Sensor B61 Tying 1 (passive) - Short circuit to UB
KMC-522161-4
KMC-522162-3
Sensor B61 Tying 1 (passive) - Cable break or short circuit to ground
Sensor B62 Tying 2 (active) - Cable break
KMC-522162-4
KMC-522163-3
Sensor B62 Tying 2 (active) - Short circuit to ground or UB
Sensor B63 Tying 3 (active) (twine) -
Short circuit to UB
KMC-522163-4
KMC-522167-3
Sensor B63 Tying 3 (active) (twine) -
Cable break or short circuit to ground
Sensor B67 Blade pre-selection active - Cable break
KMC-522167-4
KMC-522168-3
Sensor B67 Blade pre-selection active - Short circuit to ground or UB
Sensor B68 Blade pre-selection inactive - Cable break
KMC-522168-4
KMC-522169-3
Sensor B68 Blade pre-selection inactive - Short circuit to ground or
UB
Sensor B69 blade active - Cable break
KMC-522169-4
KMC-522177-3
Sensor B69 blade active - Short circuit to ground or UB
Sensor B77 Bale lifter position -
Short circuit to UB
KMC-522177-4 Sensor B77 Bale lifter position -
Cable break or short circuit to ground
Page 12
Figure
Error number
KMC-522182-3
Error text
Sensor B82 direction display - Short circuit to UB
Description
KMC-522182-4
KMC-522183-3
Sensor B82 direction display - Cable break or short circuit to ground
Sensor B83 Overload protection belt
- Cable break
KMC-522183-4
KMC-522184-3
Sensor B83 Overload protection belt
- Short circuit to ground or UB
Sensor B84 baling pressure - Short circuit to UB
KMC-522184-4
KMC-522202-3
Sensor B84 baling pressure - Cable break or short circuit to ground
Sensor B02 Tying process active -
Cable break
KMC-522202-4
KMC-522206-3
Sensor B02 Tying process active -
Short circuit to ground or UB
Sensor B06 Tying process active 1 twine tying - Cable break
KMC-522206-4
KMC-522244-0
Sensor B06 Tying process active 1 twine tying - Short circuit to ground or UB
Switch/momentary switch S4
Loosen holding arm -
KMC-522244-0 Switch/momentary switch S4
Loosen holding arm -
KMC-522245-3
KMC-522245-4
KMC-522250-16
Momentary switch S5 tying insert net
Switch/momentary switch S5 Tying insert net - Cable break
Momentary switch S5 tying insert net
Switch/momentary switch S5 Tying insert net - Short circuit to ground or
UB
Sensor
- B58 Weight measurement wrapping table at rear right
- B59 Weight measurement wrapping table at front left
- Upper limit value exceeded
Page 13
Figure
Error number
KMC-522250-18
KMC-522251-16
KMC-522251-18
KMC-522300-3
Error text
Sensor
- B58 Weight measurement wrapping table at rear right
- B59 Weight measurement wrapping table at front left
- Lower limit value below minimum
Sensor
- B57 Weight measurement wrapping table at rear left
- B60 Weight measurement wrapping table at front right
- Upper limit value exceeded
Sensor
- B57 Weight measurement wrapping table at rear left
- B60 Weight measurement wrapping table at front right
- Lower limit value below minimum
Engine M1 Tying 1 (passive) net -
Cable break or short circuit to UB
Description
KMC-522300-6
KMC-522301-3
KMC-522301-6
KMC-522303-3
KMC-522303-6
KMC-522305-3
Engine M1 Tying 1 (passive) net -
Short circuit to ground
Actuator K01/K20 Pick-up/blade group control system B - Cable break or short circuit to UB
Actuator K01/K20 Pick-up/blade group control system B - Short circuit to ground
Actuator K03/K21 Blade cassette/ blade group control system A - Cable break or short circuit to UB
Actuator K03/K21 Blade cassette/ blade group control system A - Short circuit to ground
Actuator K05 Circulation valve block -
Cable break or short circuit to UB
KMC-522305-6
KMC-522306-3
Actuator K05 Circulation valve block -
Short circuit to ground
Actuator Q06 Drive of wrapping arm -
Cable break or short circuit to UB
KMC-522306-6
KMC-522307-3
Actuator Q06 Drive of wrapping arm -
Short circuit to ground
Actuator K07 Close bale chamber -
Cable break or short circuit to UB
Page 14
Figure
Error number
KMC-522307-6
Error text
Actuator K07 Close bale chamber -
Short circuit to ground
Description
KMC-522308-3
KMC-522308-6
Actuator K08 Open bale chamber -
Cable break or short circuit to UB
Actuator K08 Open bale chamber -
Short circuit to ground
KMC-522310-3
KMC-522310-6
Actuator K10 Bale transfer wrapping table - Cable break or short circuit to
UB
Actuator K10 Bale transfer wrapping table - Short circuit to ground
KMC-522311-3
KMC-522311-6
KMC-522312-3
KMC-522312-6
Actuator K11 Move bale turner -
Cable break or short circuit to UB
Actuator K11 Move bale turner -
Short circuit to ground
Actuator K12 Raise bale transfer -
Cable break or short circuit to UB
Actuator K12 Raise bale transfer -
Short circuit to ground
KMC-522313-3
KMC-522313-6
Actuator K13 Lower bale transfer -
Cable break or short circuit to UB
Actuator K13 Lower bale transfer -
Short circuit to ground
KMC-522314-3
KMC-522314-6
KMC-522316-3
KMC-522316-6
Actuator K14 Speed of wrapping table film tear - Cable break or short circuit to UB
Actuator K14 Speed of wrapping table film tear - Short circuit to ground
Actuator K16 Open holding arms -
Cable break or short circuit to UB
Actuator K16 Open holding arms -
Short circuit to ground
KMC-522317-3 Actuator K17 Close holding arms -
Cable break or short circuit to UB
Page 15
Figure
Error number
KMC-522317-6
Error text
Actuator K17 Close holding arms -
Short circuit to ground
Description
KMC-522319-3
KMC-522319-6
Actuator K19 Wrapping arm brake -
Cable break or short circuit to UB
Actuator K19 Wrapping arm brake -
Short circuit to ground
KMC-522320-3
KMC-522320-6
KMC-522321-3
KMC-522321-6
Actuator K01/K20 Pick-up/blade group control system B - Cable break or short circuit to UB
Actuator K01/K20 Pick-up/blade group control system B - Short circuit to ground
Actuator K21 Blade control shaft A active - Cable break or short circuit to
UB
Actuator K21 Blade control shaft A active - Short circuit to ground
KMC-522326-3
KMC-522326-6
KMC-522327-3
KMC-522327-6
KMC-522330-3
KMC-522330-6
Actuator Q26 Lower feed rocker arm up to year of manufacture 2018 -
Cable break or short circuit to UB
Actuator Q26 Lower feed rocker arm up to year of manufacture 2018 -
Short circuit to ground
Actuator Q27 Raise feed rocker arm up to year of manufacture 2018 -
Cable break or short circuit to UB
Actuator Q27 Raise feed rocker arm up to year of manufacture 2018 -
Short circuit to ground
Actuator Q30 baling pressure - Cable break or short circuit to UB
Actuator Q30 baling pressure - Short circuit to ground
KMC-522333-3
KMC-522333-6
Actuator K55 Central lubrication grease - Cable break or short circuit to UB
Actuator K55 Central lubrication grease - Short circuit to ground
KMC-522338-3 Actuator K38 Pilot valve 1 - Cable break or short circuit to UB
Page 16
Figure
Error number
KMC-522338-6
Error text
Actuator K38 Pilot valve 1 - Short circuit to ground
KMC-522339-3
KMC-522339-6
Actuator K39 Pilot valve 2 - Cable break or short circuit to UB
Actuator K39 Pilot valve 2 - Short circuit to ground
KMC-522341-3
KMC-522341-6
Actuator Q41 Soft core setting -
Cable break or short circuit to UB
Actuator Q41 Soft core setting -
Short circuit to ground
KMC-522346-3
KMC-522346-6
Actuator K46 Blade pre-selection -
Cable break or short circuit to UB
Actuator K46 Blade pre-selection -
Short circuit to ground
Description
KMC-522350-3
KMC-522350-6
Actuator Q50 Tying coupling - Cable break or short circuit to UB
Actuator Q50 Tying coupling - Short circuit to ground
KMC-522352-3
KMC-522352-6
Actuator Q52 Pilot valve 3 - Cable break or short circuit to UB
Actuator Q52 Pilot valve 3 - Short circuit to ground
KMC-522353-3
KMC-522353-6
Actuator K53 Holding arms on left -
Cable break or short circuit to UB
Actuator K53 Holding arms on left -
Short circuit to ground
KMC-522354-3
KMC-522354-6
Actuator K54 Holding arms on right -
Cable break or short circuit to UB
Actuator K54 Holding arms on right -
Short circuit to ground
KMC-522373-3 Actuator K73 Additional valve baling pressure - Cable break or short circuit to UB
Page 17
Figure
Error number
KMC-522373-6
Error text
Actuator K73 Additional valve baling pressure - Short circuit to ground
Description
KMC-522375-3
KMC-522375-6
Actuator Q75 Bale lifter speed -
Cable break or short circuit to UB
Actuator Q75 Bale lifter speed -
Short circuit to ground
KMC-522376-3
KMC-522376-6
Actuator Q76 Bale lifter direction of motion - Cable break or short circuit to UB
Actuator Q76 Bale lifter direction of motion - Short circuit to ground
KMC-522400-3
KMC-522400-6
Engine M2 Tying 2 (active) net -
Cable break or short circuit to UB
Engine M2 Tying 2 (active) net -
Short circuit to ground
KMC-522401-3
KMC-522401-6
Engine M3 Tying 3 (twine) - Cable break or short circuit to UB
Engine M3 Tying 3 (twine) - Short circuit to ground
KMC-522420-3
KMC-522420-6
Lamp E20 Working lights net roll -
Cable break or short circuit to UB
Lamp E20 Working lights net roll -
Short circuit to ground
KMC-522421-3
KMC-522421-6
Lamp E21 Working lights chamber film wrapping - Cable break or short circuit to UB
Lamp E21 Working lights chamber film wrapping - Short circuit to ground
KMC-522422-3
KMC-522422-6
Lamp
- E22 Maintenance lighting side hood left
- E23 Maintenance lighting side hood right
- Cable break or short circuit to UB
Lamp
- E22 Maintenance lighting side hood left
- E23 Maintenance lighting side hood right
- Short circuit to ground
Page 18
Figure
Error number
KMC-522431-3
KMC-522431-6
KMC-522433-3
KMC-522433-6
KMC-522456-3
Error text
Lamp
- E31 Working lights wrapping table on left
- E32 Working lights wrapping table on right
- Cable break or short circuit to UB
Lamp
- E31 Working lights wrapping table on left
- E32 Working lights wrapping table on right
- Short circuit to ground
Lamp
- E33 Rear working lights, left
- E34 Rear working lights, right
- Cable break or short circuit to UB
Lamp
- E33 Rear working lights, left
- E34 Rear working lights, right
- Short circuit to ground
Actuator K56 Fill clamping hydraulics
- Cable break or short circuit to UB
Description
KMC-522456-6
KMC-522462-3
Actuator K56 Fill clamping hydraulics
- Short circuit to ground
Actuator K12 Raise bale transfer -
Cable break or short circuit to UB
KMC-522462-6
KMC-522463-3
Actuator K12 Raise bale transfer -
Short circuit to ground
Actuator K13 Lower bale transfer -
Cable break or short circuit to UB
KMC-522463-6
KMC-522471-3
KMC-522471-6
Actuator K13 Lower bale transfer -
Short circuit to ground
Actuator K03/K21 Blade cassette/ blade group control system A - Cable break or short circuit to UB
Actuator K03/K21 Blade cassette/ blade group control system A - Short circuit to ground
KMC-522500-0
KMC-522510-0
The wrong configuration values were saved
Error from force measurement amplifier
1
Figure
Page 19
Error number
KMC-522511-0
KMC-522512-0
KMC-522513-0
KMC-522520-0
KMC-522521-0
Error text Description
Measurement amplifier: Timeout of
CAN messages from KMV 1
Error from force measurement amplifier
2
Measurement amplifier: Timeout of
CAN messages from KMV 2
Figure
Error from the residual moisture control unit
Timeout for the RMS control unit detected
Error from KMB module 1 KMC-522530-0
KMC-522531-0
KMC-522532-0
KMC-522533-0
Force measurement amplifier: Timeout of CAN messages from KMB 1
Error from KMB module 2
Measurement amplifier: Timeout of
CAN messages from KMB 2
Error from KMB module 4 KMC-522536-0
KMC-522537-0
KMC-522540-0
Measurement amplifier: Timeout of
CAN messages from KMB 4
Error from LMO module 1
KMC-522541-0 Measurement amplifier: Timeout of
CAN messages from LMO 3
KMC-522900-19 TIM status message timeout - CAN disturbance between control units
The TIM status message was not sent or received within the stipulated time.
KMC-522901-19 TIM authentication failed - CAN disturbance between control units
The TIM authentication has failed.
KMC-522902-13 TIM authentication certificate on the certificate blacklist - Values invalid, not plausible or outside the calibration
A TIM server certificate is on the AEF
TIM blacklist
Page 20
Error number
KMC-522903-13
KMC-522904-13
KMC-522905-13
KMC-522906-19
Error text
TIM server uses developer certificates
- Values invalid, not plausible or outside the calibration
Description
The TIM server uses developer certificates.
The TIM function speed is not available.
TIM function speed not available -
Values invalid, not plausible or outside the calibration
TIM function valve not available -
Values invalid, not plausible or outside the calibration
TIM function speed timeout - CAN disturbance between control units
The TIM function valve is not available.
The TIM function speed was aborted due to a time-out.
Figure
KMC-522907-19 TIM function valve timeout - CAN disturbance between control units
The TIM function valve has been terminated due to a timeout.
Page 21
4
4.1
Parameter
Parameter list
4
4.1
Parameter
WARNING
Risk of injury due to unpredictable behaviour of the machine
The machine behaviour can be unpredictable if you update the software while the machine is running. This can cause accidents with serious and even fatal injuries.
Park the machine on a stable, paved and even surface.
Switch off drives and wait until coasting parts have come to a standstill.
Shut down and secure the machine. See safety routines in the operating instructions of the machine.
Parameter list
>>>
2
Parameterliste_D2515020105300029_en [ } 30]
Round baler
Supplement to operating instructions 150001622_00_en 29
Key
R = Read access
RW = Read and write access
Parameter: Rundballenpresse
Software version: D2515020105400029_200
Control unit: KMC
Rights: Driver
Page 1
KMC-0070
KMC-0076
KMC-0077
KMC-0078
KMC-0082
KMC-0083
KMC-0090
KMC-0091
KMC-0111
KMC-0112
KMC-0113
KMC-0114
KMC-0115
KMC-0116
Parameter number
KMC-0057
Parameter name
Blade cassette cleaning function activation
KMC-0058 Frequency of the blade cassette cleaning function execution
Minimum
0
0
KMC-0059 Lower blade cassette blade group zero
0
0
0
0
10
1000
10
10
0
10
0
0
0
0
3000
Maximum
1
25
1
3
2
10000
10000
5000
2500
100
100
3
10000
10000
10000
100
100
Default
0
5
0
2500
25
25
1
1000
1000
1000
25
25
0
1
1000
0
3500
Unit digits ms ms ms digits digits ms ms mV mV
1/10 digits
1/10 digits
Description
Indicates whether the cleaning function is activated and/or installed
Specifies after how many tying starts the cleaning function should be carried out.
The automatic function is disabled when 0 is set.
Specifies whether the blades are swung out when the spare blade drawer is lowered with the hydraulic blade group control system
Page 2
KMC-0176
KMC-0177
KMC-0178
KMC-0179
KMC-0185
KMC-0189
KMC-0191
KMC-0197
KMC-0198
KMC-0202
Parameter number
KMC-0117
KMC-0118
KMC-0156
KMC-0163
KMC-0164
KMC-0165
KMC-0166
KMC-0168
KMC-0175
KMC-0204
KMC-0210
KMC-0214
KMC-0218
Parameter name
Baling system fixed chamber filling setpoint delay actuation
Baling system fixed chamber Alpine mode active
0
Minimum
10
65
0
0
750
10
0
65
0
0
0
0
10
90
0
750
750
750
0
750
0
10
0
1000
692
70
Default
25
20
50
80
0
100
50
100
1000
0
50
100
0
1000
1000
1000
0
10
1000
1
5000
2000
160
Maximum
100
100
100
210
250
210
250
250
4600
100
100
110
1
4600
2000
2000
90
90
10000
Unit digits cm
%
% mV digits
% cm
%
%
%
% mV mV mV digits
% ms mV digits cm
Description
How long must setpoint filling be exceeded until tying is actuated
Indicates whether
Alpine mode has been activated
KMC-0251
KMC-0252
KMC-0253
KMC-0260
KMC-0274
KMC-0275
KMC-0333
KMC-0355
KMC-0356
KMC-0384
Parameter number
KMC-0221
KMC-0223
KMC-0224
KMC-0225
KMC-0235
KMC-0236
KMC-0241
KMC-0248
KMC-0249
Parameter name
Wrapping arms fast speed work current
KMC-0431
KMC-0432
Central lubrication unit grease duration
Central lubrication unit grease pause
0
0
Minimum
60
750
0
60
60
90
0
0
750
0
1
90
0
100
1
1000
0
150
0
0
Page 3
KMC-0454
5
15
Default
135
100
0
10
1000
1000
600
135
135
100
0
10
1
1000
120
4000
0
300
70
75
60
60
Maximum
210
110
1
25
3000
3000
1000
210
210
110
1
25
10
3000
500
5000
150
450
100
100
Unit cm cm cm digits mm digits mV
1/10 °
1/10 °
% cm mV mV digits cm cm cm min min digits
Description
Fast working speed
(as a percentage of the maximum speed)
The lubrication duration
The pause time after which a new lubrication cycle may start
Page 4
KMC-0526
KMC-0527
KMC-0528
KMC-0533
KMC-0534
KMC-0546
KMC-0547
KMC-0549
KMC-0555
KMC-0556
KMC-0580
KMC-0601
KMC-0611
KMC-0612
KMC-0613
KMC-0654
KMC-0655
Parameter number
KMC-0455
KMC-0456
KMC-0501
KMC-0508
KMC-0509
KMC-0510
KMC-0511
KMC-0524
KMC-0525
Parameter name
0
0
0
0
0
0
0
0
0
0
0
0
90
30
10
0
30
Minimum
0
0
0
10
15
0
0
0
0
0
0
50
0
120
200
2000
0
50
100
0
0
100
50
20
5
100
Default
75
430
600
180
40
0
1000
850
1050
1
30000
100
1
120
210
15000
1
450
200
1
3
110
120
200
15
170
Maximum
100
1
10000
1200
1200
1200
1200
500
200
° bar ms mm digits digits
%
Unit digits digits digits digits
1/10 °
1/10 ° ms
1/10 °
1/10 °
1/10 °
1/10 ° cm digits
Description
Page 5
Parameter number
KMC-0656
KMC-0657
KMC-0671
KMC-0672
KMC-0673
KMC-0678
KMC-0679
KMC-0681
KMC-0682
KMC-0723
KMC-0724
KMC-0730
KMC-0737
KMC-0770
KMC-0771
KMC-0772
KMC-0773
KMC-0870
Parameter name
Bale lifter speedcontrolled slope mode active
0
0
0
0
Tying motion detection delay switching on
200
Minimum
0
0
0
10
10
0
0
0
0
0
0
750
0
KMC-0871 Tying motion detection delay switching off
200
Maximum
5000
200
2
10000
10000
100
100
1200
1200
120
10000
5300
1
1
1
10000
15000
20000
20000
0
0
500
8000
500
Default
1600
150
0
1000
0
25
25
1000
800
75
3000
5000
0
600
Unit mm mm/s ms ms digits digits
1/10 °
1/10 ° cm ms mV ms ms ms ms
Description
Has slope mode of the lifter been activated?
Delay time before checking for unintentional stopping of the feed rocker arm
Delay time before checking for unintentional movement of the feed rocker arm
Page 6
Parameter number
KMC-0872
Parameter name
Tying motion detection threshold value switching on
Minimum
0
KMC-0873 Tying motion detection threshold value switching off
0
Maximum
1000
1000
Default
20
50
Unit mV mV
Description
Threshold value of the voltage change in mV for the evaluation whether the feed rocker arm is moved
Threshold value of the voltage change in mV for the evaluation whether the feed rocker arm is stopped
5 Index
A
Acknowledging error message ............................. 5
Applicable documents .......................................... 3
E
Error list ................................................................ 6
Error Messages .................................................... 5
I
Information on this document ............................... 3
M
Meaning of the supplement to the operating
instructions ........................................................... 4
P
Parameter........................................................... 29
Parameter list ..................................................... 29
Possible error types (FMI) .................................... 6
R
Re-ordering .......................................................... 3
S
Safety ................................................................... 4
V
Validity .................................................................. 3
Round baler
Supplement to operating instructions 150001622_00_en
Index 5
37
Maschinenfabrik
Bernard Krone GmbH & Co. KG
* Heinrich-Krone-Straße 10
D-48480 Spelle
* Postfach 11 63
D-48478 Spelle
' +49 (0) 59 77 / 935-0
6 +49 (0) 59 77 / 935-339
ü
www.landmaschinen.krone.de
Завантажити