Tech Lighting Arris 5-Light Bath Instructions
Add to My manuals2 Pages
Tech Lighting Arris 5-Light Bath is a lighting fixture designed for damp locations, such as bathrooms. It can be dimmed with a low-voltage electronic dimmer and is suitable for use with minimum 90°c supply conductors. The fixture comes with a mounting plate that must be installed onto an electrical box, and the fixture itself is then mounted onto the mounting plate. The fixture can be repositioned up or down, if vertical, or left or right, if horizontal, after it is mounted.
advertisement
Installation Instructions for
Arris 4-Light and 5-Light Bath
920BCARRIS
700 BC ARS4_, 700BCARS5_
1.1
B ATH C OLLECTION
G P I :
This fixture is intended to be installed utilizing NEC compliant junction boxes.
This product is suitable for damp locations.
This product can be dimmed with a low-voltage electronic dimmer.
Install the Fixture
1A
1
ALLEN
WRENCH
FIXTURE
SCREW 1
This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
Use minimum 90°c supply conductors.
1C
ANCHOR
MOUNTING
PLATE
1 1
1 Remove the fixture screws located on the top and bottom of the fixture base with the provided Allen wrench.
2
1B
Remove the mounting plate from the fixture base.
3
ANCHOR
4 Verify that the mounting plate is level before continuing.
5 Line an anchor tip with the center of an anchor hole, and push the anchor into the wall up to the threads.
6 Screw the anchor in the rest of the way with a Phillipshead screwdriver.
7 Repeat for the other anchor hole.
3
#8-32 SCREW
3 Install the mounting plate onto the electrical box with the two #8-32 screws provided.
1
1D
ANCHOR
1C
ANCHOR
6
4
SCREW
WASHER
5
8 Slide a #8 screw through a washer, and screw it into an anchor to secure the fixture base to the wall. Repeat for the other anchor.
1B
8
4 Connect the mounting plate ground wire to a suitable ground in accordance with local electrical codes.
5 Connect the black fixture wire to the hot power line wire with a wire nut.
6 Connect the white fixture wire to the neutral power line wire with a wire nut.
7 Mount the fixture by sliding it back onto the mounting plate and reinstalling the fixture screws (reversal of figure 1A).
7 Mount the fixture by sliding it back onto the mounting plate
8 If desired, reposition the fixture up or down, if vertical or left or right, if horizontal; then reinstall the fixture screws (reversal of figure 1A).
SAVE THESE INSTRUCTIONS!
2
7400 Linder Ave, Skokie, IL 60077
847.410.4400
www.techlighting.com
© 2017 Tech Lighting, L.L.C. All rights reserved. The "Tech Lighting" graphic is a registered trademark of Tech Lighting, L.L.C. Tech Lighting reserves the right to change specifications for product improvements without notification.