- For spray application of HILTI Firestop Speed Spray, a water-based material. For professional use only. -

Important Safety Instructions

Read all warnings and instructions in this manual and in the associated manuals. Save all instructions.

Modifications

Ultra Max II 595

• 1/4” x 50’ Hose

• Flex Gun

• Manifold filter removed, filter support in place for cleaning purposes

• LTX225 and LTX331 tips included

Ultra Max II 695 Hi Boy Standard

• 3/8” x 50’ Hose

• Flex Gun

• Manifold filter removed, filter support in place for cleaning purposes

• LTX225 and LTX331 tips included

• FastFlush Cleaning System

• 1/4”x3’ Whip Hose

2

Operating Procedure

Operating Procedure

Set-Up

1.

Connect the hose to the sprayer, tighten securely.

2.

Connect the other end of hose to the flex gun, tighten securely.

3.

Remove the tip and the guard from the gun.

4.

Turn the power switch OFF and plug the power supply cord into a properly grounded electrical outlet.

5.

Turn the prime valve into the prime mode. Place the siphon tube in a grounded metal pail partially filled with water.

6.

Turn the pressure control to lowest pressure.

7.

Turn the power switch ON.

8.

Increase the pressure to start the motor and allow the fluid to circulate through the drain tube for 15 seconds; then turn the pressure down.

9.

Turn the prime valve to spray (horizontal) and turn the spray gun trigger safety OFF.

10. Hold the gun against a grounded metal flushing pail.

Trigger the gun and increase the fluid pressure to

1/2. Flush the storage fluid from the unit for 1 minute.

11. Place the siphon tube in HILTI Firestop Speed

Spray.

12. Trigger the gun against the flushing pail until the

HILTI Firestop Speed Spray appears. Move the gun to the pail of HILTI Firestop Speed Spray and trigger for 20 seconds. Set the gun safety ON.

Application

1.

Assemble the tip and the guard appropriate for your unit.

• For the Ultra Max II 595 use the LTX225 tip.

• For the Ultra Max II 695 use the LTX331 tip.

2.

Spray the test pattern. Start with the pressure turned to its lowest setting then gradually increase pressure until you achieve a consistent spray pattern.

3.

Hold the gun perpendicular to the surface being sprayed.

Clean-up

1.

Turn the power OFF and unplug the sprayer.

2.

Turn the pressure to the lowest setting. Trigger the gun to relieve pressure.

3.

Remove the guard and the tip from gun.

4.

Remove the siphon tube from the HILTI Firestop

Speed Spray and place it in a bucket filled with 4 gallons of water.

5.

Plug in the sprayer and turn the power switch ON.

6.

Flush the pump, hose, and gun with water into a waste bucket.

For the Ultra Max II 595 unit put the prime valve in the spray mode.

For the Ultra Max II 695 unit use the Fast Flush

Cleaning System.

• Hold the gun trigger in and turn the prime valve down to the DRAIN position and then over to

FAST FLUSH.

• Continue flushing the system until the fluid appears clear.

7.

Mix 1/3 cup Dawn ® dish detergent with 4 gallons of clean water.

8.

Circulate the detergent/water mix through the gun and back into the supply bucket for 4 minutes.

NOTE: Hold the gun under water level to avoid detergent bubbles.

9.

Flush the detergent/water mixture from the pump, hose, and gun using clean water and a waste bucket.

10. Prime with mineral spirits to protect against freezing or corrosion.

332619A

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Frequently Answers and Questions

What safety precautions should be taken when using the sprayer?
Read and understand all warnings and instructions in the manual. Connect the sprayer to a properly grounded electrical outlet.
How do I set up the sprayer?
Connect the hose to the sprayer and flex gun, remove the tip and guard from the gun, turn on the power, prime the pump, and adjust the pressure.
How do I clean the sprayer?
Turn off the power, relieve pressure, remove the tip and guard, flush the system with water, and clean the gun with a detergent solution.
What tips should be used with the Ultra Max II 595 and Ultra Max II 695 sprayers?
Use the LTX225 tip with the Ultra Max II 595 sprayer and the LTX331 tip with the Ultra Max II 695 sprayer.
How do I prime the sprayer?
Turn the power switch ON, increase the pressure to start the motor, allow fluid to circulate through the drain tube, and then turn the pressure down.