advertisement
Wireless Weather Station
Manual
(SHS-45000EU)
Table of contents
Quick Start Procedure ........................................................................ 3
Introduction ......................................................................................... 4
Features ............................................................................................ 5
Contents of Complete Weather Station Kit ...................................... 7
Installing your weather station .......................................................... 9
Setting up the Remote Weather Sensors .......................................... 9
Setting up the Main Console Unit ...................................................... 9
Setting up the Thermo-Hygro Sensor(s) .......................................... 10
Setting up the Rain Sensor .............................................................. 10
Setting up the Solar Powered Wind Meter ....................................... 11
Using your Weather Station ............................................................. 13
Navigating between Different Modes ............................................... 14
Using the Different Weather Modes ................................................ 18
Understanding the Weather Forecast Display ................................. 21
Maintenance ...................................................................................... 34
Troubleshooting ................................................................................ 35
Appendix ............................................................................................ 37
Technical Specifications .................................................................. 42
2
Quick Start Procedure
Installing your weather station is quick and easy!
1. Insert batteries in the main console unit and power up the display with the adapter.
2. Pair the remote sensors (thermometer, wind meter, rain meter) with the main console with the following procedure: a. Open the battery case on the sensor b. Press the LINK button on the main console c. Insert the batteries in the sensor (within 30 seconds) d. The LINK led will blink for a second to indicate successful paring.
3. Measurements from the remote sensors are now visible on the display.
4. Mount the sensors on their designated location
Find more detailed instructions and information in the remainder of this manual.
3
Introduction
Congratulations on your purchase of the Wireless Weather Station. The weather station consists of a main console unit as well as an assortment of remote sensors which collect and transmit a wide range of weather data, including outdoor temperature, humidity, wind speed and direction, rain amount and rain rate. With 868 Mhz technology, you will experience a great wireless range and high reliability.
Main Console Unit
The main console unit features a radio-controlled atomic precision clock with alarm and weather forecast. It measures indoor temperature and humidity, and displays weather data collected by the remote weather sensors. It also provides indication of the indoor/outdoor temperature, pressure and humidity trends, and celestial information such as moon phase, and sunrise/set times.
Remote Weather Sensors
The remote weather sensors include a thermo-hygrometer, anemometer (wind sensor) and rain sensor. All data collected by the sensors is transmitted to the main console unit by wireless RF. The weather station supports a maximum of
5 pairings with thermo-hygrometers, allowing 5 measurements of temperature/humidity (from different locations) on the display.
4
Features
Weather Forecast
Sunny, Partly Cloudy, Cloudy, Slight Rain, Heavy Rain, Snow and Unstable
Weather conditions
Pressure
Current or historical pressure (mBar/ hPa, mmHg or inHg)
Altitude or sea level pressure adjustment for atmospheric pressure compensation
Pressure trend indication
Sea-level pressure history for the last 24 days
Sea-level pressure history bar chart
Moon phase
12 steps of moon symbols
Scans moon phase for year 2000 to 2099
Moon phase history for the last or future 39 days
Radio Controlled Clock
Time and date synchronized by radio signal DCF-77 to atomic clock precision
(time and date also manually adjustable)
Clock and Calendar (12hr/ 24 hr) (month/day or day/month)
Different combinations of clock and calendar displays
6 languages for day of week (English/ German/ French/ Italian/ Spanish/ Dutch)
Alarms
Single alarm: activated once at specified time
Weekday alarm: activated everyday from Monday to Friday at specified time
Pre-alarm: activated ahead of single or weekday alarm if channel 1 temperature falling to +2ºC or below. (Fixed 30 minutes)
Programmable snooze function (1-15 minutes)
Sunrise time and sunset time
Calculates sunrise/set times with geographical information provided by user
5
(DST, zone time offset, latitude, longitude)
Remote temperate and relative humidity, with trend indication
Indoor and outdoor temperature and relative humidity display (ºC or ºF)
Temperature and relative humidity trend indication
Dew point display
Max and Min memory for temperature and relative humidity
Comfort level indicator
Analyzes current environmental conditions (Comfort, Wet and Dry)
Rainfall measurement
Records rainfall amount for the last hour, last 24 hours, last day, last week and last month (inch or mm).
Daily rainfall alert if rainfall for the current day exceed pre-specified amount.
Wind
Temperature at place of anemometer.
Temperature adjusted to wind chill factor. (ºC or ºF)
Wind direction compass display. Wind direction angles available as compass points or bearings.
Average wind speed and gust speed (mph, m/s, knots, and km/h)
Daily Maximum wind speed and gust speed memory.
Wind speed alert for average wind speed and wind gust speed.
6
Contents of Complete Weather Station Kit
Before installing your weather station, please check that the following items are complete:
Hardware Components
Main Console Unit
Fittings
AC/DC
7.5V output adaptor
Thermo-Hygro Sensor
Rain Sensor:
-Funnel shaped Lid with Battery Hatch
-Sensor Base
-Bucket See-saw
Mechanism
-Protective Screen
4 screws for securing unit to ground
7
Anemometer (Wind
Sensor):
-Wind Cups
-Wind Vane
- Anemometer arm
- Anemometer base
4 screws for securing unit to vertical surface
8
Installing your weather station
Setting up the Remote Weather Sensors
To pair the remote sensors with the main console unit, first connect the AC/DC adaptor with the main console and press the ‘ON’ button to power up. Keep the sensors nearby. The procedure for pairing a sensor to the main console is as follows:
1. Press the ‘link’ button on the main console
2. Insert the required batteries into the sensor (within 30 seconds of pressing ‘link’).
3. The red LED on the display will light up for a second, indicating a successful paring.
Pair the sensors within line of sight of the console unit. When pairing is complete, mount the sensors on their designated location, but always first test reception before permanently mounting your weather station. Transmission range may be affected by trees, metal structures and electronic appliances.
Setting up the Main Console Unit
1. Insert 2x “AA” size 1.5V batteries. These serve as backup batteries only, for when power is temporarily interrupted. Always use the AC/DC adapter as well.
2. Connect the AC/DC adaptor.
3. If placing the console unit on a table or horizontal surface, set up the table stand and you can put it on the table.
4. If mounting the console unit on a wall or vertical surface, remove the table stand and use the fitting provided.
Placement tips:
Make sure that the console unit is within receiving range of all remote sensors.
The console unit measures indoor temperature, humidity, pressure and receives signals from all remote sensors and radio-clock broadcasts. Avoid
9
placing the console unit in the following areas:
•
Direct sunlight and surfaces which radiate and emit heat.
•
Near heating and ventilation devices, such as heating ducts or air conditioners.
•
Areas with interference from wireless devices (such as cordless phones, radio headsets, baby listening devices) and electronic appliances.
Setting up the Thermo-Hygro Sensor(s)
1. Open the latch at the base of the thermo-hygro sensor.
2. Press the ‘link’ button on the main console.
3. Insert 2 x “AA” size 1.5V batteries (within 30 seconds).
4. Replace the latch and mount unit at desired location.
Placement tips:
•
The thermo-hygro sensor should be in an area with free air circulation and sheltered from direct sunlight and other extreme weather conditions. Place the unit in a shaded area, such as under a roof.
•
Use the wall mount and fittings provided if mounting the unit on a vertical surface.
•
Avoid placing the sensor near sources of heat such as chimneys.
•
Avoid any areas which collect and radiate heat in the sun, such as metal, brick or concrete structures, paving, patios and decks.
•
Ideally, place the sensor above natural surfaces such as a grassy lawn.
•
The international standard height for measurements of air temperature is at 1.25m (4 ft) above ground level.
Setting up the Rain Sensor
1. Unlock the funnel-shaped top of the rain sensor by turning both knobs on the sides of the rain sensor in an anti-clockwise direction.
2. Press the ‘link’ button on the main console.
3. Lift the top off the base and insert 2x “AA” size 1.5V batteries into the battery holder (within 30 seconds).
4. Replace the lid and secure into place by turning the knobs clockwise.
10
5. Place the rain sensor in a location such that precipitation can fall directly into the sensor, ideally 2-3 ft above the ground.
6. It may be secured into place by using the four screws provided.
7. The sensor must be accurately level for optimum performance. To check if the sensor is level, remove the lid and check if the ball bearing inside is at the midpoint of the leveler.
Additionally, a bubble level or carpenter’s level may be used.
8. Attach the protective screen onto the top of the lid. The screen will prevent any debris entering the sensor.
Placement tips:
•
The rain sensor should be placed in an open area away from walls, fences, trees and other coverings which may either reduce the amount of rainfall into the sensor, deflect the entry of wind-blown rain, or create extra precipitation runoff. Trees and rooftops may also be sources of pollen and debris.
•
To avoid rain shadow effects, place the sensor at a horizontal distance corresponding to two to four times the height of any nearby obstruction.
•
It is important that rain excess can flow freely away from the sensor.
Make sure that water does not collect at the base of the unit.
•
The rainfall measurement mechanism utilizes a magnet, hence do not place any magnetic objects around the proximity of the sensor.
Setting up the Solar Powered Wind Meter
1. Assemble the wind cups to the anemometer arm
2. Attach the assembled anemometer to the base.
3. Open the battery holder in the base by unscrewing the screws.
4. Make sure to disconnect the cable from the battery back that is used by the solar panel (it might already be disconnected).
5. Press the ‘link’ button on the main console.
6. Insert 2 x “AA” size 1.5V batteries into the battery holder in the base
(within 30 seconds).
7. Now reconnect the cable from the battery back.
8. Mount the anemometer onto a vertical surface, using the fittings provided.
11
The wind direction measurement is calibrated in the factory. If you find the wind direction to be inaccurate, it is possible to calibrate the wind meter with the following procedure: a. Insert the batteries b. Point the wind vane towards the north. Use a compass or map if necessary. c. Use a pin to press the “SET” key which is in the battery compartment of the wind sensor.
Placement tips:
•
Check that wind can travel freely around the anemometer and is not distorted by nearby buildings, trees or other structures.
•
For better results, place the anemometer at least 3m above local structures and obstacles. The ground creates a frictional effect to wind flow and will attenuate readings.
•
Aim for maximum exposure of the anemometer to the commonest wind directions in your area.
•
The official mounting location for anemometers is 10m (33 ft) above ground level in a clear unobstructed location.
Connecting with HomeWizard
Visit www.homewizard.com
for more information
HomeWizard is a device that easily lets you connect wireless smart home devices and control them from a smartphone or tablet with one easy-to-use app. This weather station is HomeWizard compatible. When connected with
HomeWizard, you will be able to view real-time data in the HomeWizard app, receive push notifications for weather conditions and share your own weather station online.
First, make sure that all sensors are properly connected to the main console.
HomeWizard only synchronizes with the main console unit and gets all information of individual sensors from here.
1. Start the HomeWizard app and select ‘Menu > Add sensor > Weather
Station (868)’.
2. Select ‘pair’ and press the LINK button on the main console.
12
Using your Weather Station
Buttons
UP (+)
- Switches to next mode in anti-clockwise direction
- Increment for setting parameters
DOWN (-)
SET
MEMORY (MEM)
HISTORY
ALARM/CHART
CHANNEL
SNOOZE
- Switches to next mode in clockwise direction
- Decrement for setting parameters
- Rotates display for current mode
- Press and hold to enter setup or change units
- Confirmation for setting parameters
- Shows records for moon phase, temperature, humidity, rain and wind.
- Shows history for sea-level pressure
- Shows time alarms and alerts for temperature, rain and wind.
- Press and hold to enter alarm/alert setup
- Press and hold in Pressure and Weather Forecast
Mode to view different bar-charts
- Changes temperature and humidity display to selected channel
- Press and hold to enable cycling display of paired thermometers
- Enters Snooze mode when alarm is activated
LINK
- Used for pairing the sensors with the main console.
13
Navigating between Different Modes
There are 6 modes available on the main console unit, and each one displays a different category of data. When display is in a certain mode, its corresponding icon will start flashing.
To navigate between the different modes from the main console unit, press UP
(+) to cycle through the modes in a clockwise direction or DOWN (-) to cycle through the modes in an anti-clockwise direction.
Pressure and Weather Forecast Mode
•
Current pressure, trend, and history bar-chart
•
Weather forecast
•
Moon phase
Clock and Alarm Mode
•
Radio Controlled clock showing current time and calendar
•
Single alarm, weekday alarm and pre-alarm
14
Sunrise/Sunset Mode
•
Sunrise and sunset times
•
Longitude and Latitude of local area
Temperature and Humidity Mode
•
Temperature and humidity trend and readings for indoor and selected channel
•
Comfort level
•
Dew point
•
Temperature alerts
15
Rain Mode
•
Precipitation amount for last hour, last 24 hour, yesterday, last week and last month
•
Rainfall alert
Wind Mode
•
Wind Chill
•
Temperature at place of anemometer
•
Wind direction
•
Wind speed
•
Wind gust
•
Alert for wind speed and wind gust speed
16
17
Using the Different Weather Modes
Pressure and Weather Forecast Mode
This part of the display indicates the current pressure, sea level pressure, weather forecast, moon phase and pressure trend.
A number of historical statistics can also be viewed, such as the sea-level pressure values for the last 24 hours, moon phase for the previous and next 39 days, as well as a pressure/ temperature/ humidity history bar-chart.
Pressure values may be displayed inHg, hPa/mBar or mmHg, and altitude values may be displayed in meters or feet.
Accessing Pressure and Weather Forecast Mode
From the main console unit: Press UP (+) or DOWN (-) until the weather forecast icon on the upper left of the display starts flashing.
Setting Pressure Parameters during Initial Start-Up
During the initial start-up of the main console unit, all functions in Pressure and
Weather Forecast mode will be locked until the pressure settings are configured.
1. Choose Pressure Units:
The unit icon “inHg” or “mmHg” or “hPa/mBar” should be flashing.
Press UP (+) or DOWN (-) to select pressure unit as inHg, hPa/mBar or mmHg
Press SET to confirm your selection.
2. Choose Altitude Units:
Press UP (+) or DOWN (-) to select altitude unit as feet or meters.
Press SET to confirm your selection.
3. Set Altitude:
Press UP (+) or DOWN (-) to adjust value. Press and hold either button for fast advance.
Press SET to confirm your selection.
4. Upon completion the display will be returned to Pressure and Weather
Forecast Mode.
18
Note: After initial start-up the altitude cannot be adjusted again until the main console unit is restarted.
Viewing Pressure and Altitude Data
In Pressure and Weather Forecast Mode, each press of SET rotates display between:
•
Sea level pressure
•
Local pressure
•
Local altitude
Setting the Sea Level Pressure
5. In Pressure and Weather Forecast Mode, press SET until the sea level pressure is displayed.
6. Press and hold SET. The Sea Level Pressure display should be flashing.
7. Set Sea Level Pressure:
8. Press UP (+) or DOWN (-) to adjust value. Press and hold either button for fast advance.
9. Press SET to confirm your selection.
10. Upon completion the display will be returned to Pressure and Weather
Forecast Mode.
Setting the Pressure and Altitude Units
1. In Pressure and Weather Forecast Mode, press SET until local pressure is displayed.
2. Press and hold MEMORY (MEM). The pressure unit should be flashing.
3. Set Local Pressure Units:
Press UP (+) or DOWN (-) to adjust value.
Press SET to confirm your selection.
4. Set Altitude Units:
Press UP (+) or DOWN (-) to adjust value.
Press SET to confirm your selection.
5. Set Sea-Level Pressure Units:
Press UP (+) or DOWN (-) to adjust value.
19
Press MEMORY (MEM) to confirm your selection.
6. Upon completion the display will be returned to Pressure and Weather
Forecast Mode.
Viewing the Sea Level Pressure History
1. In all modes, pressing HISTORY will toggle the sea level pressure display.
2. When sea level pressure is displayed, press HISTORY repeatedly to view sea level pressure data for each of the last 24 hours.
3. If no buttons are pressed for 5s, the display automatically returns to
Pressure and Weather Forecast Mode.
Viewing the Pressure/ Temperature/ Humidity Bar-Charts
The bar-chart on the display can be configured to display the history data for sea-level pressure, temperature or humidity for channel 1.
In Pressure and Weather Forecast Mode, press and hold ALARM/CHART to toggle the bar-chart between:
•
Sea-level pressure (“PRESSURE” should be displayed)
•
Temperature (Thermometer icon and “CH1” should be displayed)
•
Humidity (RH icon and “CH1” should be displayed)
Viewing Moon Phase History and Forecast
1. In Pressure and Weather Forecast Mode, press MEMORY (MEM).
2. “+ 0 days” should be flashing.
3. View Moon Phase History / Forecast:
Press UP (+) or DOWN (-) to choose number of days forward (+ days) or backward (- days) from current date. Press and hold either button for fast advance.
4. The corresponding moon phase will be shown.
5. To exit, press MEMORY (MEM).
Otherwise, if no buttons are pressed for 5s the display automatically returns to Pressure and Weather Forecast Mode.
20
Understanding the Weather Forecast Display
Display Weather Forecast Status
Sunny
Partly Cloudy
Cloudy
Rain or
Unstable Weather
Snow
NOTE:
- The accuracy of a general pressure-based weather forecast is about 70%.
- The weather forecasts. It may not necessarily reflect the current situation.
- The “Sunny” icon, as applies to night time, implies clear weather.
21
Understanding the Moon Phase Diagram
Clock and Alarm Mode
The main console unit can be configured to display the time, calendar or UTC time. There are three time alarms available on the console unit:
Single alarm: activated once at specified time
Weekday alarm: activated everyday from Monday to Friday at specified time
Pre-alarm: activated at specified time interval (Fixed 30 min) ahead of weekday alarm, if channel 1 temperature falling to +2 ºC or below.
The snooze duration for the above alarms can also be programmed (0-15 min).
Accessing Clock and Alarm Mode
From the main console unit: Press UP (+) or DOWN (-) until the clock icon beside the time/date display starts flashing.
Setting up the Time, Date and Language
1. In Clock and Alarm Mode, press and hold SET to enter clock and calendar setup.
The day of week should start flashing in the display.
2. Set Language:
Press UP (+) or DOWN (-) to select language for day of week: English,
German, French, Italian, Spanish or Dutch
Press SET to confirm your selection.
3. Select City Code:
Press UP (+) or DOWN (-) to select city code for your local area.
Press SET to confirm your selection.
4. Set Daylight Saving Time Option:
Press UP (+) or DOWN (-) to turn DST option on or off. Press and hold
22
either button for fast advance.
Press SET to confirm your selection.
Repeat the above instructions to set year, month, day, calendar display format (day/month or month/day), time display format (12 hr/ 24 hr), local hour and local minutes.
5. Upon completion the display will return to normal Clock and Alarm
Mode.
Note: Press and hold SET anytime during the setup to return to normal Clock and Alarm Mode. All settings made will be discarded.
Rotating between Different Clock/Calendar Displays
In Clock and Alarm Mode, each press of SET rotates clock display between:
•
Hour: Minute: Weekday
•
Hour: Minute for UTC (Coordinated Universal Time)
•
Hour: Minute: City
•
Hour: Minute: Second
•
Month: Day: Year (or Day: Month Year depending on settings)
Activating/Deactivating the Time Alarms
1. In Clock and Alarm Mode, each press of ALARM/CHART rotates clock display between:
Weekday Alarm Time (displays OFF if weekday alarm deactivated)
- Single Alarm Time (displays OFF if single alarm deactivated)
- Pre-Alarm Time (displays OFF if pre-alarm deactivated)
2. When the above alarms are displayed, pressing UP (+) or DOWN (-) will activate/deactivate the corresponding alarm.
Note: Press SET anytime during alarm selection mode to return to normal clock display.
Setting up the Time Alarms
1. In Clock and Alarm Mode, press ALARM/CHART to select alarm which you wish to configure.
Press and hold ALARM/CHART until hour starts flashing in the display
2. Set Alarm Hour:
23
Press UP (+) or DOWN (-) to adjust value. Press and hold either button for fast advance.
Press ALARM/CHART to confirm your selection.
3. Set Alarm Minutes:
Press UP (+) or DOWN (-) to adjust value. Press and hold either button for fast advance.
Press ALARM/CHART to confirm your selection.
4. Set Duration of Snooze Function (all three alarms share same snooze time duration):
Press UP (+) or DOWN (-) to adjust value. Press and hold either button for fast advance.
Press ALARM/CHART to confirm your selection.
5. Upon completion the display will be returned to the alarm selection screen.
Note: Pre-alarm cannot be activated if weekday alarm or single alarm is not enabled.
Disabling/Entering Snooze when Time Alarms are Activated
To Enter Snooze:
Press SNOOZE/LIGHT to enable snooze function.
Note: Alarm will automatically enter snooze mode if no key is pressed after the alarm sounds for 2 minutes. This will occur for a maximum of three times.
To Disable Alarm(s):
Press ALARM/CHART to disable the alarm (s).
Note: For weekday alarm, pressing ALARM/CHART will only disable the alarm for the current day. The alarm will be activated again the next day (if it falls within Monday to Friday).
Activating/Deactivating Radio Clock Reception
The main console unit synchronizes the time and date with radio clock broadcasts to maintain atomic clock precision.
To turn this function on/off:
24
Press and hold UP (+).
If RC reception is activated, a triangular tower icon will start flashing beside the clock icon.
If RC reception is deactivated, the triangular tower icon will disappear.
Icon RC Reception Strength
Undefined data
(Flashing)
Reception failed for 24 hours
Weak signal, but can be decoded
Strong signal
Note: The radio controlled signal for time (DCF 77) is transmitted from the central atomic clock in Frankfurt/Main in short intervals. It has a reception range of approx. 1500 km. Obstructions such as concrete walls can reduce the signal range.
Sunrise/Sunset Mode
The main console unit computes the sunrise and sunset times from the user-configured location data. This includes the longitude, latitude, time zone and DST (Daylight Saving Time). Choosing a suitable city code for your area will automatically generate the correct values for the location data.
Should you wish to input your own location data or if a suitable city code could not be found, choose “USR” as the city code during setup.
A searching function is also available, which allows the sunrise/sunset times for different dates to be viewed.
25
Accessing Sunrise/Sunset Mode
From the main console unit: Press UP (+) or DOWN (-) until the sunrise and sunset icons on the lower left of the display start flashing.
Setting up the Location Data
1. In Sunrise/Sunset Mode, press and hold SET to enter location data setup.
2. The city code in the Time and Alarm display should start flashing.
3. Set City Info:
Press UP (+) or DOWN (-) to select city code for your local area. The corresponding longitude and latitude will be shown along with the city.
Should you wish to input your own geographical coordinates, choose
“USR” as the city code
Press SET to confirm your selection.
4. If “USR” was chosen, you will be asked to input your geographical coordinates.
Set Degree of Latitude:
Press UP (+) or DOWN (-) to adjust value. Press and hold either button for fast advance.
Press SET to confirm your selection.
5. Repeat above procedure to set minute of latitude, degree of longitude, minute of longitude, time zone of the city, and DST selection.
6. Upon completion the display will be returned to Sunrise/Sunset Mode.
Note: Press and hold SET anytime during the setup to return to normal Clock and Alarm Mode. All settings made will be discarded.
Viewing the Location Data
In Sunrise/Sunset Mode, each press of SET rotates display between:
•
Time and sunrise/ sunset Times
•
Calendar and sunrise/ sunset Times
•
Calendar and longitude/ latitude
Viewing Sunrise/Sunset Times for Different Dates
1. In Sunrise/Sunset Mode, press MEMORY (MEM).
The date should be flashing.
26
2. Press UP (+) or DOWN (-) to adjust date. Press and hold either button for fast advance.
3. The corresponding sunrise and sunset times will be displayed for the selected date.
4. Press MEMORY (MEM) or SET to return display to Sunrise/Sunset
Mode.
Understanding the Sunrise/Sunset Display
The sunrise time being displayed differs during the morning and the afternoon/night.
From 12 am to 12 pm: The sunrise time for the current day will be displayed.
From 12 pm to 12 am: The sunrise time for the next day will be displayed.
“NEXT DAY” icon will be displayed above the sunrise time.
At certain locations (especially those at high latitudes), sunrise and sunset events may not occur within a 24 hour time frame.
Display
FULL
----
Sunrise status
Sunrise at previous day
No sunrise for the whole day
Display
FULL
-----
Sunset status
Sunset at next day or later
No sunset for the whole day
Temperature and Humidity Mode
The weather station supports pairing with up to 5 remote thermo-hygro sensors.
The temperature may is shown in degrees Celsius ºC. The trend (rising, steady or falling) of all values is also indicated on the display.
The main console unit uses the indoor temperature and humidity data to compute a comfort level rating of Wet, Comfort or Dry.
A temperature alert function is available for each channel. It can be programmed to sound if the channel temperature exceeds or falls below the pre-configured upper and lower limits.
Note: The temperature alerts have a 0.5 ºC hysteresis to prevent the alerts
27
from sounding constantly due to small fluctuations near the alert value. This means that after the temperature reaches the alert value, it will have to fall below the alert value plus the hysteresis to deactivate the alert.
Accessing Temperature and Humidity Mode
From the main console unit: Press UP (+) or DOWN (-) until the IN icon on the upper right of the display starts flashing.
Viewing Temperature and Humidity Display for each Channel
For Static Display:
In Temperature and Humidity Mode, each press of CHANNEL rotates display between different channels.
For Cycling Display:
To enable automatic rotating between different channel displays, press and hold CHANNEL, until the P icon is displayed. Each valid channel will now be alternately displayed for 5s.
Rotating Between Temperature and Dew Point Display
In Temperature and Humidity Mode, each press of SET rotates temperature display between:
- Temperature and Relative Humidity
- Dew Point Temperature and Relative Humidity
Activating/Deactivating the Temperature Alerts
1. In Temperature and Humidity Mode, each press of ALARM/CHART rotates channel temperature display between:
- Current Temperature for corresponding channel
- Upper Temperature Alert (displays OFF if deactivated): ▲icon displayed
- Lower Temperature Alert (displays OFF if deactivated): ▼ icon displayed
2. When the above alerts are displayed, pressing UP (+) or DOWN (-) will activate/deactivate the corresponding alert.
28
Setting up the Temperature Alerts
1. In Temperature and Humidity Mode, press ALARM/CHART to select alarm which you wish to configure.
Press and hold ALARM/CHART until channel temperature and ▲or▼ icon starts flashing in the display.
2. Set Value for Temperature Alert:
Press UP (+) or DOWN (-) to adjust value. Press and hold either button for fast advance.
3. Press ALARM/CHART to confirm your selection.
4. Upon completion the display will be returned to the temperature alert selection screen.
Disabling when Temperature Alarms are Activated
To Disable Temperature Alarm(s):
Press ALARM/CHART to disable the alarm (s).
Viewing the Max/Min Channel Temperature and Humidity
In Temperature and Humidity Mode, each press of MEMORY (MEM) rotates channel temperature and humidity display between:
- Current temperature and humidity at remote sensor
- Minimum temperature and humidity at remote sensor
- Maximum temperature and humidity at remote sensor
Resetting the Max/Min Channel Temperature and Humidity Memory
In Temperature and Humidity Mode, press and hold MEMORY (MEM) to clear memory for all channels.
Remote Sensor Status
The wave icon above the current channel display shows the connection status of the corresponding remote sensor.
29
Icon Status
Searching for remote sensor signals
Corresponding remote sensor successfully linked
Communication error between remote sensor and main console
Activating Main Console Unit to Search for All Remote Sensor
Signals
The main console unit may be manually activated to search for signals from all remote sensors. Only use this function of the ‘communication error’ icon is visible on the main console:
Press and hold DOWN (-) to enforce a search.
Rain Mode
The main console unit records the total amount of rainfall for the last hour, last
24 hours, yesterday, last week and last month. The rainfall may be displayed in mm or inches.
A daily rainfall alert function is available which can be programmed to sound if the daily rainfall exceeds a pre-configured limit.
Accessing Rain Mode
From the main console unit: Press UP (+) or DOWN (-) until the RAIN icon on the display starts flashing.
Viewing Rain Statistics
In Rain Mode, each press of SET or MEMORY (MEM) rotates display between different rain statistics:
•
Last hour
•
Last 24 hour
•
Yesterday
•
Last week
30
•
Last month
Tip: For an estimation of the rain rate, the Last Hour rainfall value can be understood as “inch/hr” or “mm/hr”.
Resetting the Rainfall Statistics Memory
In Rain Mode, press and hold MEMORY (MEM) to reset all rainfall statistics.
Setting Units for Rain Display (inch or mm)
In Rain Mode, press and hold SET to convert units between mm and inches.
Activating/Deactivating the Daily Rainfall Alert
1. In Rain Mode, each press of ALARM/CHART rotates display between the current rainfall statistics and the daily rainfall alert (“ALARM HI” will be displayed).
If the alert is deactivated, “OFF” will be shown, otherwise the rainfall alert value is shown.
2. When the rainfall alert is displayed, pressing UP (+) or DOWN (-) will activate/deactivate it.
Setting up the Daily Rainfall Alert
1. In Rain Mode, press ALARM/CHART to display rainfall alert.
2. Press and hold ALARM/CHART until rainfall alert and “ALARM HI” starts flashing in the display.
3. Set Value for Rainfall Alert:
Press UP (+) or DOWN (-) to adjust value. Press and hold either button for fast advance.
Press ALARM/CHART to confirm your selection.
4. Upon completion the display will be returned to the rainfall alert display.
Disabling when Daily Rainfall Alert is Activated
To Disable Rainfall Alert:
1. Press ALARM/CHART to disable the alert.
31
Wind Mode
The wind direction is shown by an animated compass display. Its angle can be displayed as compass points (i.e. NW) or in bearings from the north (i.e. 22.5º).
The upper left of the wind display can be set to indicate the temperature at the anemometer or the temperature adjusted with a wind chill factor.
The lower left of the wind display indicates the average wind speed for the last
10 minutes, as well as gust, wind speed alert and gust alert information. It can also show records of the maximum values of wind speed and gust attained for the current day.
The wind speed and gust alert functions can be programmed to sound if the wind speed or gust exceeds a pre-configured limit. The wind speed may be displayed in km/h, mph, m/s or knots.
Note: The wind speed alert has a 5 mph hysteresis and the wind gust speed alert has a 7 mph hysteresis. The hysteresis is to prevent the alerts from sounding constantly due to small fluctuations near the alert value. This means that after the wind speed reaches the alert value, it will have to fall below the alert value plus the hysteresis to deactivate the alert.
Accessing Wind Mode
From the main console unit: Press UP (+) or DOWN (-) until the WIND icon on the display starts flashing.
Configuring Wind Display
In Wind Mode, each press of SET rotates display between:
•
Temperature with wind chill, wind direction in bearings
•
Temperature with wind chill, wind direction in compass points
•
Temperature at anemometer, wind direction in compass points
•
Temperature at anemometer, wind direction in bearings
Setting Units for Wind Speed Display (km/h , mph, m/s or knots)
In Wind Mode, press and hold SET to convert wind speed units between km/h, mph, m/s or knots.
32
Viewing Wind Statistics
In Wind Mode, each press of MEMORY (MEM) rotates wind speed display between:
- Current wind speed
- Daily maximum wind speed (“DAILY MAX” is displayed)
- Gust speed (“GUST” is displayed)
- Daily maximum gust speed (“GUST DAILY MAX” is displayed)
Resetting the Wind Statistics Memory
In Wind Mode, press and hold MEMORY (MEM) to reset all wind statistics.
Activating/Deactivating Wind Alerts
1. In Wind Mode, each press of ALARM/CHART rotates wind speed display between:
•
Current wind speed
•
Wind speed alert (“ALARM HI” displayed)
•
Gust alert (“GUST ALARM HI” displayed)
If the alert is deactivated, “OFF” will be shown, otherwise the alert value is shown.
2. When a wind alert is displayed, pressing UP (+) or DOWN (-) will activate/deactivate it.
Setting up the Wind Alerts
1. In Wind Mode, press ALARM/CHART to select alarm which you wish to configure.
2. Press and hold ALARM/CHART until alert and corresponding icon starts flashing in the display.
3. Set Value for Alert:
Press UP (+) or DOWN (-) to adjust value. Press and hold either button for fast advance.
Press ALARM/CHART to confirm your selection.
4. Upon completion the display will be returned to the wind alert selection screen.
Disabling when Wind Alert is Activated
Press ALARM/CHART to disable the alert.
33
Maintenance
Changing Batteries
The battery statuses of the sensors are checked every hour. If the low battery indicators light up, replace the batteries for the corresponding unit immediately.
Changing Batteries for the Remote Sensors
1. Replace the batteries following the setup instructions for the corresponding sensor.
2. When the batteries are properly installed, the sensor will resume sending signals to the main console unit.
Cleaning
The main console unit and outer casings for the remote sensors can be cleaned with a damp cloth. Small parts can be cleaned with a cotton tip or pipe-cleaner.
Never use any abrasive cleaning agents and solvents. Do not immerse any units with electronic parts in water or under running water.
Anemometer
-Check that the wind vane and wind cups can spin freely and are free from dirt, debris or spider webs.
Rain Sensor
Like all rain gauges, the rain sensor is prone to blockages due to its funnel shape. Checking and cleaning the rain sensor from time to time will maintain the accuracy of rain measurements.
•
Detach the protective screen and lid. Remove any dirt, leaves or debris by cleaning the items with soapy water and a damp cloth. Clean small holes and parts with a cotton tips or pipe-cleaner.
•
Look out for spiders or insects that might have crawled into the funnel.
•
Also clean the swinging mechanism with a damp cloth.
34
Troubleshooting
“The display shows “0.00” for weather parameter(s)”
The display will show “0.00” when the wireless link is lost with the remote sensor.
Check or replace the batteries for the corresponding sensor.
If the above does not solve the problem, check the wireless transmission path from the corresponding sensor to the main console unit and change their locations if necessary.
Although wireless signals can pass through solid objects and walls, the sensor should ideally be within the line of sight of the console unit.
The following may be the cause of reception problems:
- Distance between remote sensor and main console unit too long.
- Signal shielding materials such as metal surfaces, concrete walls or
dense vegetation in the path of transmission.
- Interferences from wireless devices (such as cordless phones, radio headsets, baby listening devices) and electronic appliances.
“The weather forecast is inaccurate.”
The weather forecast is a prediction of weather after 12-24 hours, and may not reflect current weather conditions.
PRECAUTIONS
This product is engineered to give you years of satisfactory service if you handle it carefully. Here are a few precautions:
1. Do not immerse the unit in water.
2. Do not clean the unit with abrasive or corrosive materials. They may scratch the plastic parts and corrode the electronic circuit.
3. Do not subject the unit to excessive force, shock, dust, temperature or humidity, which may result in malfunction, shorter electronic life span, damaged battery and distorted parts.
35
4. Do not tamper with the unit's internal components. Doing so will invalidate the warranty on the unit and may cause unnecessary damage. The unit contains no user-serviceable parts.
5. Only use fresh batteries as specified in the user's manual. Do not mix new and old batteries as the old ones may leak.
6. Always read the user's manual thoroughly before operating the unit.
DISCLAIMER
- The content of this manual is subject to change without further notice.
- Due to printing limitation, the displays shown in this manual may differ from the actual display.
- The contents of this manual may not be reproduced without the permission of the manufacturer.
36
Appendix
City Codes
US and Canadian Cities
Zone
DST
City Code Offset
Atlanta, Ga.
Austin, Tex.
Baltimore, Md.
Birmingham, Ala.
Boston, Mass.
Calgary, Alba., Can.
Chicago, IL
Cincinnati, Ohio
Cleveland, Ohio
Columbus, Ohio
Dallas, Tex.
Denver, Colo.
Detroit, Mich.
El Paso, Tex.
Houston, Tex.
Indianapolis, Ind.
Jacksonville, Fla.
Las Vegas, Nev.
Los Angeles, Calif.
BOS
YYC
CGX
CVG
CLE
ATL
AUS
BWI
BHM
CMH
DAL
DEN
DTW
ELP
HOU
IND
JAX
LAS
LAX
-5
-7
-6
-5
-5
-5
-6
-5
-6
-6
-5
-5
-7
-5
-6
-7
-5
-8
-8
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
NO
SU
SU
SU
SU
SU
SU
City
Memphis, Tenn.
Miami, Fla.
Milwaukee, Wis.
Minneapolis, Minn.
Montreal, Que., Can.
Nashville, Tenn.
New Orleans, La.
New York, N.Y.
Oklahoma City, Okla.
Omaha, Neb.
Ottawa, Ont., Can.
Philadelphia, Pa.
Phoenix, Ariz.
Pittsburgh, Pa.
Portland, Ore.
San Antonio, Tex.
San Diego, Calif.
San Francisco, Calif.
San Jose, Calif.
OMA
YOW
PHL
PHX
PIT
PDX
SAT
SAN
SFO
SJC
MKE
MSP
YMX
BNA
MSY
NYC
OKC
Zone
Code Offset DST
MEM
MIA
-6
-5
SU
SU
-6
-6
-5
-6
-6
-5
-6
SU
SU
SU
SU
SU
SU
SU
-8
-6
-7
-5
-6
-5
-5
-8
-8
-8
NO
SU
SU
SU
SU
SU
SU
SU
SU
SU
37
City
Seattle, Wash.
St. Louis, Mo.
Tampa, Fla.
Toronto, Ont., Can.
Zone
Code Offset
SEA
STL
-8
-6
TPA
YTZ
-5
-5
DST
SU
SU
SU
SU
City
Vancouver, B.C., Can.
Washington, D.C.
Vancouver, Canada
Zone
Code Offset DST
YVR
DCA
-8
-5
SU
SU
VAC -8 SU
38
World Cities
City Code
Addis Ababa, Ethiopia ADD
Adelaide, Australia ADL
ALG Algiers, Algeria
Amsterdam,
Netherlands
Ankara, Turkey
AMS
AKR
Asunción, Paraguay
Athens, Greece
Bangkok, Thailand
Barcelona, Spain
ASU
ATH
BKK
BCN
Beijing, China
Belgrade, Yugoslavia
Berlin, Germany
BEJ
BEG
BER
Birmingham, England
Bogotá, Colombia
BHX
BOG
Bordeaux, France
Bremen, Germany
BOD
BRE
Brisbane, Australia
Brussels, Belgium
Bucharest, Romania
Budapest, Hungary
Buenos Aires,
Argentina
BNE
BRU
BBU
BUD
BUA
Code City
3
9.5
1
Time
Zone
-3
Time
8
1
1
7
1
1
2
-3
2
1
1
0
-5
10
1
2
1
DST
NO
SA
NO
City
Cairo, Egypt
Calcutta, India (as Kolkata)
Cape Town, South Africa
SE
SE
NO
SE
SE
NO
SE
SE
NO
SE
SE
SE
SE sp
SE
NO
SE
Caracas, Venezuela
Chihuahua, Mexico
Copenhagen, Denmark
Córdoba, Argentina
Dakar, Senegal
Dublin, Ireland
Durban, South Africa
Frankfurt, Germany
Glasgow, Scotland
Guatemala City, Guatemala
Hamburg, Germany
Havana, Cuba
Helsinki, Finland
Hong Kong, China
Irkutsk, Russia
Jakarta, Indonesia
Johannesburg, South Africa
DKR
DUB
DUR
FRA
GLA
CCS
CUU
CPH
COR
GUA
HAM
HAV
HEL
HKG
IKT
JKT
JNB
NO
DST
Kingston, Jamaica
City
Code
CAI
CCU
CPT
2
5.5
2
Time
Zone
DST sg
NO
NO
NO
KIN
Code
NO
-5
Time DST
39
NO
SE
SH
SE
NO
SE
SE
NO
SK
NO
NO
SU
SE
NO
NO
SE
2
1
0
0
0
-4
-6
1
-3
-5
2
-6
1
8
8
7
2
Kinshasa, Congo
Kuala Lumpur,
Malaysia
La Paz, Bolivia
Lima, Peru
Lisbon, Portugal
Liverpool, England
London, England
Lyon, France
Madrid, Spain
Manila, Philippines
Marseille, France
Melbourne, Australia
Mexico City, Mexico
Milan, Italy
Montevideo, Uruguay
Moscow, Russia
Munich, Germany
Nairobi, Kenya
Nanjing (Nanking),
China
Naples, Italy
New Delhi, India
Odessa, Ukraine
Osaka, Japan
FIH
NKG
NAP
DEL
ODS
KIX
LPL
LON
LYO
MAD
MNL
KUL
LPB
LIM
LIS
MRS
MEL
MEX
MIL
MVD
MOW
MUC
NBO
Zone
1
5.5
2
8
1
9
0
0
1
1
8
-5
0
8
-4
3
1
1
-3
3
1
10
-6
NO Oslo, Norway
NO
SE
NO
SE
NO
Tripoli, Libya
Vienna, Austria
Warsaw, Poland
Zürich, Switzerland
OSL
Zone
1 SE
NO
SE
NO
SE
SA
SU
NO
NO
SE
SE
SE
SE
SE
SM
SK
SE
NO
Panama City, Panama
Paris, France
Perth, Australia
Prague, Czech Republic
Rangoon, Myanmar
Reykjavík, Iceland
Rio de Janeiro, Brazil
Rome, Italy
Salvador, Brazil
Santiago, Chile
São Paulo, Brazil
Shanghai, China
Singapore, Singapore
Sofia, Bulgaria
Stockholm Arlanda, Sweden
Sydney, Australia
Tokyo, Japan
RGN
RKV
RIO
ROM
SSA
PTY
PAR
PER
PRG
SCL
SPL
SHA
SIN
SOF
ARN
SYD
TKO
6.5
0
-3
1
-3
8
1
-5
1
1
10
8
2
9
-4
-3
8
TRP
VIE
WAW
ZRH
1
1
2
1
NO
NO
SE
SE
SE
SE
NO sc sb
NO
SE
NO
SE
NO
NO sb
NO
SE
SE
SA
NO
40
DST definition
SA = Australian DST.
SB = South Brazilian DST. Changes annually.
SC = Chile DST
SE = Standard European DST.
SG = Egypt DST
SH = Havana, Cuba DST
SI = Iraq and Syria DST
SK = Irkutsk & Moscow DST
SM = Montevideo, Uruguay DST
SN = Namibia DST
SP = Paraguay DST
SQ = Iran DST maybe changed annually.
ST = Tasmania DST
SU = Standard American DST.
SZ = New Zealand DST
NO DST = no = Places that do not observe DST
ON = Always add 1 hour with local standard time
41
Technical Specifications
Weather Station Receivers
Receiver (Supply=6.0V, Ta=23°C) and Sensor unit (Supply=3.0V, Ta=23°C)
RF Transmission Frequency 868 MHz
RF Reception Range
Thermo-hygro Sensor
Wind Sensor, Rain Sensor
Barometric Pressure Range
50 meters maximum (Line of Sight)
50 meters maximum (Line of Sight)
(At sea level )
Altitude Compensation Range
Barometric Pressure resolution
Barometric Pressure accuracy
500 hpa to 1100hpa
(374.5 mmHg to 823.8 mmHg )
-200m to +5000 m ( -657 ft to 16404 ft )
0.1 hpa ( 0.003 inHg, 0.08 mmHg )
+/- 5 hpa ( 0.015 inHg, 0.38 mmHg )
Outdoor Temperature Display Range -40°C to 80°C ( -40°F to 176°F )
Indoor Temperature Display Range -9.9°C to 60°C ( 14.2°F to 140°F)
Operating Temperature
Storage Temperature
Temperature accuracy
Temperature resolution
Humidity Display Range
Humidity accuracy
Humidity resolution
-5°C to 50°C ( 23°F to 122°F)
-20°C to 70°C( -4°F to 158°F)
+/- 1°C or +/- 2°F
0.1°C or 0.2°F
0% to 99%
+/-5% (within 25% - 80%)
1%
Receiving Cycle
Remote Thermo./Hygro.
Rain gauge
Wind sensor
Sunrise and Sunset Accuracy
Wind Direction Range
Wind Direction Accuracy
Wind Direction Resolution
Wind Direction Starting Threshold
Wind Speed Range around 47s
183s
33s
+/- 1min ( latitude within +/- 50° )
16 positions
+/-11.25°
22.5°
3mph
0 to 199.9mph
42
Wind Speed Accuracy +/- ( 2mph + 5% )
Wind Speed Starting Threshold 3mph
Wind/Gust Speed Disply Update Interval 33 seconds
Wind/Gust Sampling Interval
1h/24h/yesterday Rainfall Range
Last week/ last month Rainfall Range
Temperature Sensing Cycle (indoor)
Humidity Sensing Cycle (indoor)
11 seconds
0.0 to 1999.9 mm ( 78.73 inch )
0 to 19999 mm ( 787.3 inch )
10s
10s
Power
Main unit
Remote Thermo.-Hygro unit
Remote Anemometer unit
Remote Rain gauge unit
Weight
Main unit : 298g (with build-in battery)
Remote Thermo.-Hygro unit
Remote Anemometer unit
Remote Rain gauge unit
Dimension
Main unit
Remote Thermo.-Hygro unit
Remote Anemometer unit
Remote Rain gauge unit
AC/DC adaptor 5V use 2 pcs UM-3 or “AA” 1.5V battery use 2 pcs UM-3 or “AA” 1.5V battery use 2 pcs UM-3 or “AA” 1.5V battery
43g (without battery)
315g (without battery)
290g (without battery)
185(L) x 140(H) x 12(D) mm
37.5(L) x 110(H) x 23(D) mm
405(L) x 375(H) x 160(D) mm
163(L) x 177(H) x 119(D) mm
43
advertisement
Related manuals
advertisement
Table of contents
- 3 Quick Start Procedure
- 4 Introduction
- 5 Features
- 7 Contents of Complete Weather Station Kit
- 9 Installing your weather station
- 9 Setting up the Remote Weather Sensors
- 9 Setting up the Main Console Unit
- 10 Setting up the Thermo-Hygro Sensor(s)
- 10 Setting up the Rain Sensor
- 11 Setting up the Solar Powered Wind Meter
- 13 Using your Weather Station
- 14 Navigating between Different Modes
- 18 Using the Different Weather Modes
- 21 Understanding the Weather Forecast Display
- 34 Maintenance
- 35 Troubleshooting
- 37 Appendix
- 42 Technical Specifications