Elko SHT-1, SHT-1/2, SHT-3, SHT-3/2 Manual
Add to My manuals22 Pages
Elko SHT-3 is a 1-channel digital time switch that offers precise control over various electrical devices based on time and programming. With its versatile functionality, you can automate tasks like switching on/off lights, fans, pumps, or heaters according to your desired schedule.
advertisement
▼
Scroll to page 2
of
22
![Elko SHT-1, SHT-1/2, SHT-3, SHT-3/2 Manual | Manualzz Elko SHT-1, SHT-1/2, SHT-3, SHT-3/2 Manual | Manualzz](http://s2.manualzz.com/store/data/068193692_1-74cef09621474793d2a55b1e5a04991d-360x466.png)
Digital time switch E N SHT-1 SHT-1/2 SHT-3 SHT-3/2 Content Symbol, Connection ...................................................................................... 3 Warning .......................................................................................................... 4 Characteristics ............................................................................................... 5 Technical parameters .................................................................................... 6 Versions of time switches, Load ................................................................... 7 Description .................................................................................................... 8 - 9 Control ............................................................................................................ 10 Mode precendence, Manual output control ............................................... 11 Program setting ............................................................................................. 12 Program adjustment ..................................................................................... 13 Program deleting, Deleting of all programs ............................................... 14 Date and time setting ................................................................................... 15 Setting of programmed/random mode ....................................................... 16 Setting of pulse/cyclic mode interval .......................................................... 17 Holiday mode ................................................................................................ 18 Exit from menu, Reset ................................................................................... 19 Example of programming ............................................................................. 20 -2- Symbol SHT-1 SHT-3 A1 16 18 A2 15 SHT-1/2 SHT-3/2 A1 A2 16 18 26 28 15 Connection SHT-1 SHT-3 SHT-1/2 SHT-3/2 A1 16 15 18 Un A1 16 15 18 Un A2 A2 26 25 28 -3- 25 E N Warning Device is constructed for connection in 1-phase exceeded. For installation and setting use screw-driver cca main alternating current voltage and must be 2 mm. The device is fully-electronic - installation should installed according to norms valid in the state be carried out according to this fact. Non-problematic of application. Connection according to the function depends also on the way of transportation, details in this direction. Installation, connection, setting storing and handling. In case of any signs of destruction, and servicing should be installed by qualified electrician deformation, non-function or missing part, don´t install staff only, who has learnt these instruction and functions and claim at your seller it is possible to dismount the of the device. This device contains protection against device after its lifetime, recycle, or store in protective overvoltage peaks and disturbancies in supply. For correct dump. function of the protection of this device there must be suitable protections of higher degree (A,B,C) installed in front of them. According to standards elimination of disturbancies must be ensured. Before installation the main switch must be in position “OFF” and the device should be de-energized. Don´t install the device to sources of excessive electro-magnetic interference. By correct installation ensure ideal air circulation so in case of permanent operation and higher ambient temperature the maximal operating temperature of the device is not -4- Characteristics - OUT ON - pulse - 1 position in memory, range 1-99s. - OUT OFF - turn off the switching mode. - Set time of pulse/delay is on one channel the same for all programs (it is not possible to set more pulses with different durations on one channel). - “Holiday mode - “ - possibility to choose the period, when the device will be not switching according a standard program and will be blocked for the pre-set time. E - 100 memory positions (by SHT-1/2 and SHT-3/2 are N those 100 positions common for both channels). - Programming of device can be realize even under voltage and also even in back-up mode. - Output relays operates only under voltage. - Automatic change-over between summer/winter time (setting is for time zone GTM+1:00). - Back-lighted LCD display. - Easy and quick setting by 4 control buttons. - Sealable transparent cover of the front panel. - Time switch is back-up with in-built lithium element, which saves data during voltage failure. Back-up time reserve - up to 3 years. - Supply voltage: AC 230V or AC/DC 12-240V. - 2-Module, DIN rail mounting, saddle terminals. - Serves for controlling of various types of appliances in dependance on real time (automation-switching of heating, pumps, ventilation etc.). Appliances can be operated in concrete periodic time cycles or according a pre-set program (depends on type, see the chart Versions of time switches). - SHT-1, SHT-3: 1-channel version. - SHT-1/2, SHT-3/2: 2-channel version (to each channel can be assigned an individual program). - Possibility to control two independent circuits. - By SHT-3, SHT-3/2 is not possible to integrate daily and night mode on one channel. By SHT-3/2 is possible to set a different mode on each channel. - Setting of switching by: - program (PROG) - switching according programs set in SET 1 . Possibility to set the repeat every minute or every hour. - random (AUTO ) - random switching in 10-120 min interval. - permanently manualy . - Switching modes (OUT): - OUT ON - normal - 2 positions in memory (close /open), shortest time of closing is 1 min. - OUT ON - cyclic - 2 positions in memory (pulse/delay), - Device is delivered with pre-programmed actual time, range 1-99s. which is permanently displayed also in back-up mode. -5- Technical parameters 230 UNI Supply terminals: A1 - A2 Supply voltage: AC/DC 12-240V (AC 50-60Hz) Consumption: AC 0.5 - 2VA / DC 0.4 - 2W Supply voltage: AC 230V / 50 - 60Hz Consumption: AC max. 14VA / 2W Supply voltage tolerance: -15 %; +10 % Real time back-up: yes Summer/winter time: automatic Output: Number of contacts: - SHT-1, SHT-3: 1 x changeover (AgSnO2) - SHT-1/2, SHT-3/2: 2 x changeover (AgSnO2) Rated current: 16A / AC1 Switching capacity: 4000 VA / AC1, 384W / DC Peak current: 30A / <3s Switching voltage: 250V AC1 / 24V DC Min. switching capacity DC: 500 mW Mechanical life: > 3x107 > 0.7x105 Electrical life (AC1): Time circuit Real time back-up when de-energi.: up to 3 years Accuracy: max. ±1s/ day at 23°C Minimum interval: 1 min. Data stored for: min. 10 years Cyclic output: 1-99s Pulse output: 1-99s Program circuit Number of memory places: Program (SHT-1; SHT-1/2): Program(SHT-3, SHT-3/2): Data readout: Other information Operating temperature: Storage temperature: Electrical strength: Operating position: Mounting: Protection degree: Overvoltage category: Pollution degree: Max. cable size (mm2): Dimensions: Weight - SHT-1, SHT-3: - SHT-1/2, SHT-3/2: Standards: -6- 100 daily, weekly daily, weekly, monthly , yearly (up to year 2095) LCD display, with back light -20.. +55 °C -30.. +70 °C 4 kV (supply - output) any DIN rail EN 60715 IP10 clips, IP40 from front panel III. 2 solid wire max. 2x2.5 or 1x4 with sleeve max. 1x2.5 or 2x1.5 90 x 35.6 x 64 mm (UNI)-130 g, (230)-110 g (UNI)-143 g, (230)-125 g EN 61812-1, EN 61010-1 Versions of time switches output Type of product 1 channel SHT-1 z z SHT-1/2 SHT-3 time program 2 channels week z z month year z z z z z z z z z z z M M 1000W z SHT-3/2 day Load Type of load Contact material AgSnO2, Contact 16A cos φ ≥ 0.95 HAL.230V AC1 AC2 AC3 AC5a Uncompensated 250V / 16A 250V / 5A 250V / 3A 230V / 3A (690VA) AC5a Compensated 230V / 3A (690VA) max. input C=14uF AC6a AC7b AC12 AC13 AC14 AC15 x 250V / 3A x x 250V / 6A 250V / 6A M M DC1 DC3 DC5 DC12 DC13 DC14 24V / 10A 24V / 3A 24V / 2A 24V / 6A 24V / 2A x Type of load Contact material AgSnO2, Contact 16A K Type of load Contact material AgSnO2, Contact 16A AC5b -7- E N Description Output - channel 1 (16-15-18) Supply voltage terminal (A1) A1 18 15 16 7 Auto Display with back-light 12 6 0 SHT-1/2 RESET Control buttons MAN 2 OK MAN ESC PRG + _ Place for seal A2 26 25 28 Supply voltage terminal (A2) Output - channel 2 (26-25-28) -8- Indicates the day in the week Operating modes indication Indication (1st channel) 1 2 3 4 5 6 Auto Prog Man 7 Indication (2nd channel) Indicates 12 / 24 mode Indication of time/date/setting menu Indicates summer / winter mode E N Bargraf Control button PRG / + 0 6 12 18 24 Control button MAN2 / ESC Reset Control button OK Control button MAN1 / - CONTROL OF A DISPLAY WITH BACKLIGHT Display is illuminated with a back-light for 10 s from last button press. Permanent on / off is activated by synchronic press of buttons MAN, ESC, OK . After permanent on/off activation, display will flash shortly. -9- Device differs short and long button press. In the manual marked as: - short button press (<1s) - long button press (>1s) c/d - number indicates button press sequence Control Prog 18 24 18 12 24 6 12 18 24 0 6 12 18 24 setting of pulse /cyclic mode interval 18 24 - entrance into chosen program (EDIT) - one level up 12 - entrance into required menu - confirmation holiday mode 6 0 setting of programmed / random mode Man 0 - quick shifting during setting of values 6 - browsing in menu - setting of values date and time setting 0 - entrance into programming menu setting, adjustment and program deleting 12 6 0 - back to the starting menu exit from menu 0 6 12 18 24 After 30s of inactivity (from the last press of any button) will device automatically returns into starting menu. - 10 - Mode precendence Precendence of controlling modes highest priority of controlling mode display output mode ON / OFF manual control ON / OFF holiday mode ON / OFF auto lowest priority of controlling mode 4 0 6 12 18 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 - controls channel 1 relay on 4 Prog Man 24 normal mode - is superior to other set modes 4 Man pulse-cyclic mode / ON / OFF Manual output control 4 ON / OFF random mode for switching relay off - 11 - - controls channel 2 (by SHT-1/2 and SHT-3/2) E N SET 1 Program setting 7 6 5 0 6 12 18 0 24 6 12 18 24 4 4 3 Man 0 Prog 0 6 12 18 0 6 0 6 12 18 6 12 18 0 24 24 2 24 6 12 18 24 0 6 12 18 24 1 24 24 Prog 24 0 24 6 12 18 24 24 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 d - setting of hour and minute of program start /end 6 12 18 24 ............ 0 6 12 18 24 d c only by yearly mode: setting of year, month and day d c - 12 -x d c OUT - setting of switching mode - OUT ON - normal - OUT ON - cyclic - OUT ON - pulse - OUT OFF - turn off the switching mode. If the program memory is full, display announces it by notice FULL. d c - by SHT-3 and SHT-3/2 - selection of daily / night mode d c - by SHT1/2 and SHT3/2 - selection of channel c ADD - add a new program only by daily mode: ON/OFF - setting of the program activity in concrete day of the week - long press (>1s) - short press (<1s) c/d - press sequence SET 1 Program adjustment 7 6 5 0 6 12 18 0 24 6 12 18 24 4 4 Man 3 0 4 0 Prog 6 12 18 0 6 12 18 12 18 24 2 24 24 0 6 12 18 24 0 6 12 18 24 24 1 4 24 Man 24 24 0 6 12 18 24 24 24 24 0 18 24 0 6 12 24 0 6 12 18 0 6 12 18 24 12 18 0 6 12 24 0 6 12 18 6 12 18 dc 24 0 d - time adjustment (hours / minutes) 6 12 18 24 0 6 12 18 only by yearly mode: adjusting of date (year, month and day) 0 dc 24 dc OUT - selection / adjustment of switching mode 18 dc 24 - by SHT-1/2 and SHT-3/2 - by SHT-3 and selection / SHT-3/2 adjustment of selection / channel adjustment of set mode 6 dc 0 oc 24 c 18 - selection / entrance into chosen program 12 d 6 c EDIT - adjustment of already saved programs 18 12 6 0 24 18 12 6 0 0 6 6 only by daily mode: ON/OFF selection / adjustment of program activity in concrete day of the week - long press (>1s) - short press (<1s) c/d - press sequence - 13 - 24 E N SET 1 Program deleting Deleting of all programs 4 Man 4 4 Prog 6 12 18 4 Man Man 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 - program selection - long press OK - deleting of chosen program - in starting menu (time is shown on display) - press simultaneously button PRG and OK and display announces a notice ALL o c DEL - deleting of individual programs d c 0 - press button OK to complete the deleting of all set programs - long press (>1s) - short press (<1s) c/d - press sequence - 14 - SET 2 Date and time setting 4 Man Prog 6 12 18 24 0 6 12 18 24 0 6 12 18 0 24 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 minutes setting c d d c hour setting d c setting of time in 24 or 12 hour format d c c day setting d c month setting d year setting c 0 d activation of changeover between summer/winter time - long press (>1s) - short press (<1s) c/d - press sequence - 15 - E N SET 3 Setting of programmed / random mode 4 Man Prog 0 6 12 18 Auto 24 0 6 12 18 24 0 6 0 Man 12 18 24 0 6 6 12 0 6 Prog 18 24 0 6 12 12 18 18 24 24 Man 0 6 12 18 24 d c - by SHT-1/2 and SHT-3/2 - selection of channel c PROG - relay is switching according programs set in menu SET 1 In starting mode by chosen channel flashs symbol Prog or (Automatically preset switching according PROG). d AUTO - relay is switching randomly in 10-120 min interval on display. - 16 - - long press (>1s) - short press (<1s) c/d - press sequence SET 4 Setting of pulse / cyclic mode interval 4 Man Prog 0 6 12 18 24 0 6 12 18 0 24 6 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 E N 24 c d - by SHT-1/2 and SHT-3/2 selection of channel c d c d - setting of delay / cycle duration (by - pulse mode do not set) - setting of pulse /cycle duration Setting of time of pulse / cyclic mode switching is realized by SET 1 . - 17 - - long press (>1s) - short press (<1s) c/d - press sequence SET 5 Holiday mode 4 Man Prog 0 6 12 18 24 0 6 12 18 24 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 c holiday mode ending month setting d c holiday mode ending year setting In the starting mode during the activation of holiday mode, flashs symbol on display. - 18 - d d c holiday mode starting day setting c d holiday mode starting month setting c d c holiday mode starting year setting d c holiday mode setting d holiday mode ending day setting End Exit from menu - return to the starting mode 1 4 4 Prog Man Man 0 6 12 24 0 6 12 18 24 0 6 12 18 24 18 0 0 6 12 18 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 E N 24 Activated by, covered RESET button, short press with blunt spike (with max. 2mm diameter). After press, information about type of device and firmware version will displayed for 3 s and then device performs in starting mode. Reset will delete an actual time, set time of pulse/cyclic mode and all temporary functions (manual or random switch output). Reset will save all set programs. - long press (>1s) - short press (<1s) c/d - press sequence - 19 - Example of programming Setting of SHT-3/2 to be activated from Monday till Friday at 8:00 by program 0 ( 16:30 by program 1 ( ). ) , and deactivated from Monday till Friday at 5 4 4 setting of switching on Man 3 7 2 1 6 12 18 6 24 Prog 0 24 24 24 24 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 0 24 6 12 18 24 0 6 12 18 24 0 6 12 18 0 24 6 12 18 0 24 6 12 18 24 0 6 d c setting of activity Mo-Fri time of turning on 12 18 24 ............ d c turn on a normal mode daily program d c d c channel 1 program 0 add the program programming c starting menu d turning off the activity Sat-Sun save 5 4 setting of switching off 3 7 2 1 6 24 4 Prog 24 24 24 24 0 6 12 24 0 6 12 24 0 6 12 24 0 6 12 24 0 6 12 18 24 18 c 24 d turning off the activity Sat-Sun 0 6 12 18 24 ............ save 0 6 12 18 24 0 6 12 18 24 - 20 - 12 6 setting of activity Mo-Fri d 0 time of turning off d c turn off a normal mode 18 d c daily program 18 d c channel 1 18 c program 1 18 24 18 12 6 0 return into starting menu - long press (>1s) - short press (<1s) c/d - press sequence Palackého 493 769 01 Holešov, Všetuly, CZ Tel.: +420 573 514 211 Fax: +420 573 514 227 E-mail: [email protected] Web: www.elkoep.com 3042, 3043, 3041, 3040, 3676, 3675, 2901, 2904 -02VJ-26/2014 Rev.: 4
advertisement