Cree Lighting UR Series Installation Instructions

Add to My manuals
6 Pages

advertisement

Cree Lighting UR Series Installation Instructions | Manualzz

UR Series

LED Upgrade Kit

Includes: 24" or 48" Linear Option

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always be followed including the following:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

1. DANGER – RISK OF SHOCK – DISCONNECT POWER BEFORE INSTALLATION

DANGER – RISQUE DE CHOC – COUPER L’ALIMENTATION AVANT L’INSTALLATION

2.

WARNING – Risk of fire or electric shock. LED Upgrade Kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Product must be installed in accordance with NEC or your local electrical code. If you are not familiar with these codes and requirements, contact a qualified electrician.

ATTENTION- Risque d’incendie ou de choc électrique. L’installation du kit upgrade LED exige la connaissance des systèmes électriques pour luminaires. Si non qualifié, ne tentez pas d’installation. Ce produit doit être installé conformément à NEC ou votre code électrique local. Si vous n’êtes pas familier avec ces codes et ces exigences, veuillez contacter un électricien qualifié.

3.

WARNING – Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of the LED upgrade kit. Check for enclosed wiring and components.

ATTENTION - Risque d’incendie ou de choc électrique. Câblage électriques peuvent être endommagés lors du perçage pour l’installation du kit upgrade LED. Vérifier les fils et composants.

4.

WARNING – Risk of fire or electric shock. Check the existing wiring for damage before installing upgrade kit. Do not install if existing wires are damaged.

ATTENTION- Risque d’incendie ou de choc électrique. Vérifiez si le câblage existant n’est pas endommagé avant l’installation du kit upgrade LED. Ne pas installer si des fils sont endommagés.

5.

WARNING – To prevent wiring damage or abrasion, do not expose wires to the edge of sheet metal or any other sharp objects.

ATTENTION - Pour éviter les dégâts de câblage par l’abrasion, ne pas mettre en contact les fils

électriques avec des bords de tôle ou d’autres objets pointus.

6.

WARNING – Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings.

ATTENTION - Risque d’incendie ou de choc électrique. Installez ce kit seulement dans les luminaires qui ont les caractéristiques de construction et les dimensions dans les photographies ou les dessins de la page suivante.

7.

The retrofit assembly is accepted as a component of a luminaire where the suitability of the combination shall be determined by ul or authorities having jurisdiction

Le montage rétracté est considéré comme le composant d’un système lumineux incandescent où l’adaptation à la structure doit être déterminée par le csa ou les autorités en vigueur.

8.

Only those open holes indicated in the photographs and/or drawings may be made or altered as a result of kit installation. Do not leave any other open holes in an enclosure of wiring or electrical components.

Seulement les trous indiqués dans les photographies ou les dessins peuvent être faits ou altérés pour l’installation du kit upgrade LED. Ne laissez aucun trou ouvert dans le compartiment

électrique.

SAVE THESE INSTRUCTIONS FOR FUTURE

REFERENCE

LIST OF SUPPLIED COMPONENTS

INSTALLATION INSTRUCTIONS

INSTRUCTIONS D’INSTALLATION

NOTES:

1. Upgrade Kit is for installation in a nominal

1x4, 2x2, or 2x4 Listed dry or damp location fluorescent troffer, wrap or strip luminaire, with or without a diffuser.

The luminaire shall have the following minimum dimensions:

• 2-15/16" deep pan

• 3" wide minimum wiring compartment

• 43" minimum length to accommodate 48" lightbars and 22" minimum length to accommodate

24” lightbars

• Only ONE kit is to be installed per luminaire

2. Consult your local authority regarding disposal or recycling of removed ballast and lamp.

Upgrade UR2 Single Kit contains the following parts:

UR2-48 drivers are used with UR48 Light

Bars only.

UR2-24 drivers are used with UR24 Light

Bars only.

(2) – LED lightbars

(1) – Driver (may be packaged separately)

(4) – Mounting Clips

(8) – M3.5 x 20mm Sheet Metal Screws

(1) - Relamping label

Upgrade UR3 Single Kit contains the following parts:

UR3-48 drivers are used with UR48 Light

Bars only.

UR3-24 drivers are used with UR24 Light

Bars only.

(3) – LED lightbars

(1) – Driver (may be packaged separately)

(6) – Mounting Clips

(12) – M3.5 x 20mm Sheet Metal Screws

(1) - Relamping label

Upgrade UR4 Single Kit contains the following parts:

UR4-48 drivers are used with UR48 Light

Bars only.

(4) – LED lightbars

(1) – Driver (may be packaged separately)

(8) – Mounting Clips

(16) – M3.5 x 20mm Sheet Metal Screws

(1) - Relamping label

1 of 6 LPN00218X0004A0_A

TO INSTALL

1

2

NOTE: The instructions below reflect the steps necessary for retrofit of a typical fluorescent troffer luminaire. These steps are functionally identical for retrofit of a typical wrap or strip luminaire.

STEP 1:

Locate latches on the lens frame and release them allowing lens frame to swing open. Carefully let lens frame hang. See

Figure 1.

STEP 2:

Remove existing linear fluorescent tubes and properly dispose of them. See Figure 2.

3

2 of 6

4 5

STEP 3:

To remove the wiring compartment, squeeze the sides in and pull down and set aside. See Figure 3 .

STEP 4:

Locate the existing ballast and remove the screw holding the ballast to the housing. Retain screw for mounting replacement driver. See Figure 3.

STEP 5:

To remove the ballast from housing, cut the leads from the ballast to the socket housing on both ends of the luminaire and cap socket leads. See Figure 4 and 5.

NOTE: When cutting leads, leave the smallest amount of wire attached to luminaire.

LPN00218X0004A0_A

6

8

9

10

3 of 6

7

STEP 6:

Cut the leads from the ballast to the input power ensuring to leave as much length as possible for electrical connections. Remove ballast from housing and properly dispose of. See Figure 6.

STEP 7:

Push exposed socket leads back into socket housing on each side of the luminaire or cap any exposed accessible leads. See Figure 7.

STEP 8:

Prepare input power by stripping input power leads 1/4”.

See Figure 8.

STEP 9:

Bring new driver into housing using mounting holes from old ballast and secure it using ballast screw that was removed in Step 4. Ensure that the existing luminaire housing is properly grounded to ensure proper driver grounding. See Figure 9 .

NOTE: If housing has multiple locations for power supply, new driver can be secured in any of these locations.

STEP 10:

Make electrical connection per “Electrical Connections” section on page 5.

NOTE: Ensure that the driver is properly grounded to luminaire using supplied screw from Step 9.

STEP 11:

Bring wiring compartment previously removed in Step 3 into the housing. Carefully tuck all leads and wire connectors into the wire compartment. Reattach wire compartment by snapping into place over driver insuring no wires are pinched. See Figure 10.

NOTE: Route the driver outgoing leads through the wiring compartment allowing leads to be exposed through the end of the wiring compartment. See Figure 10.

LPN00218X0004A0_A

11

12

13

4 of 6

STEP 12:

Snap (2) supplied mounting clips onto each LED lightbar. See Figure 11.

STEP 13:

Bring LED lightbar into housing and reposition clips on LED lightbar as needed. For temporary placement of LED lightbar the clips have magnets located on the bottom of the clip.

Repeat this step for each LED lightbar supplied in kit.

STEP 14:

Once all LED lightbars are in desired position permanently secure them to housing by drilling

(2) 3/32" pilot holes at each bracket location and then installing (2) M3.5 x 20mm sheet metal screws into mounting brackets at each end of the LED lightbar. See Figure 12.

STEP 15:

Connect the power supply leads connector, that is exposed at the end of the wiring compartment with the LED lightbar connector. See Figure 13 .

NOTE: Place the relamp label, provided in the kit, on the lighting compartment. Make sure that the label is visible.

STEP 16:

Close the lens door and secure the latches.

LPN00218X0004A0_A

Cree Part #s

UR2-24-26L-830-10V5-

UNV

UR2-24-26L-835-10V5-

UNV

UR2-24-26L-840-10V5-

UNV

UR2-24-26L-850-10V5-

UNV

UR3-24-39L-830-10V5-

UNV

UR3-24-39L-835-10V5-

UNV

UR3-24-39L-840-10V5-

UNV

UR3-24-39L-850-10V5-

UNV

UR2-24-32L-830-10V5-

UNV

UR2-24-32L-835-10V5-

UNV

UR2-24-32L-840-10V5-

UNV

UR2-24-32L-850-10V5-

UNV

UR3-24-48L-830-10V5-

UNV

UR3-24-48L-835-10V5-

UNV

UR3-24-48L-840-10V5-

UNV

UR3-24-48L-850-10V5-

UNV

UR2-48-42L-830-10V5-

UNV

UR2-48-42L-835-10V5-

UNV

UR2-48-42L-840-10V5-

UNV

UR2-48-42L-850-10V5-

UNV

UR3-48-63L-830-10V5-

UNV

UR3-48-63L-835-10V5-

UNV

UR3-48-63L-840-10V5-

UNV

UR3-48-63L-850-10V5-

UNV

UR4-48-84L-830-10V5-

UNV

UR4-48-84L-835-10V5-

UNV

UR4-48-84L-840-10V5-

UNV

UR4-48-84L-850-10V5-

UNV

UR3-24-48L-830-LB

UR3-24-48L-835-LB

UR3-24-48L-840-LB

UR3-24-48L-850-LB

UR2-48-42L-830-LB

UR2-48-42L-835-LB

UR2-48-42L-840-LB

UR2-48-42L-850-LB

UR3-48-63L-830-LB

UR3-48-63L-835-LB

UR3-48-63L-840-LB

UR3-48-63L-850-LB

UR4-48-84L-830-LB

UR4-48-84L-835-LB

UR4-48-84L-840-LB

UR4-48-84L-850-LB

Light Bar Part #

UR2-24-26L-830-LB

UR2-24-26L-835-LB

UR2-24-26L-840-LB

UR2-24-26L-850-LB

UR3-24-39L-830-LB

UR3-24-39L-835-LB

UR3-24-39L-840-LB

UR3-24-39L-850-LB

UR2-24-32L-830-LB

UR2-24-32L-835-LB

UR2-24-32L-840-LB

UR2-24-32L-850-LB

UR3-24-230-DR

UR3-24-230-DR

UR3-24-230-DR

UR3-24-230-DR

UR2-48-290-DR

UR2-48-290-DR

UR2-48-290-DR

UR2-48-290-DR

UR3-48-290-DR

UR3-48-290-DR

UR3-48-290-DR

UR3-48-290-DR

UR4-48-290-DR

UR4-48-290-DR

UR4-48-290-DR

UR4-48-290-DR

Driver Part #

UR2-24-230-DR

UR2-24-230-DR

UR2-24-230-DR

UR2-24-230-DR

UR3-24-230-DR

UR3-24-230-DR

UR3-24-230-DR

UR3-24-230-DR

UR2-24-230-DR

UR2-24-230-DR

UR2-24-230-DR

UR2-24-230-DR

5 of 6

Cree Part #s

UR2-48-50L-830-10V5-

UNV

UR2-48-50L-835-10V5-

UNV

UR2-48-50L-840-10V5-

UNV

UR2-48-50L-850-10V5-

UNV

UR3-48-75L-830-10V5-

UNV

UR3-48-75L-835-10V5-

UNV

UR3-48-75L-840-10V5-

UNV

UR3-48-75L-850-10V5-

UNV

UR4-48-100L-830-10V5-

UNV

UR4-48-100L-835-10V5-

UNV

UR4-48-100L-840-10V5-

UNV

UR4-48-100L-850-10V5-

UNV

Driver Part #

UR2-48-420-DR

UR2-48-420-DR

UR2-48-420-DR

UR2-48-420-DR

UR3-48-420-DR

UR3-48-420-DR

UR3-48-420-DR

UR3-48-420-DR

Light Bar Part #

UR2-48-50L-830-LB

UR2-48-50L-835-LB

UR2-48-50L-840-LB

UR2-48-50L-850-LB

UR3-48-75L-830-LB

UR3-48-75L-835-LB

UR3-48-75L-840-LB

UR3-48-75L-850-LB

UR4-48-420-DR

UR4-48-420-DR

UR4-48-420-DR

UR4-48-420-DR

UR4-48-100L-830LB

UR4-48-100L-835LB

UR4-48-100L-840LB

UR4-48-100L-850LB

LPN00218X0004A0_A

ELECTRICAL CONNECTIONS - 0-10V DIMMING (120-277VAC AND 347V MODELS)

STEP 1:

Connect power conduit and dimming conduit to access plates (and expanded J-Box if needed).

STEP 2:

Make the following Electrical Connections: a. Connect the black fixture lead to the voltage supply Line position, Hot.

b. Connect the white fixture lead to the neutral supply position.

c. Connect the green or green/yellow ground lead to the supply ground lead.

d. If 0/1-10v Dimming is used, connect the violet lead to the supply positive dimming lead.

e. If 0/1-10v Dimming is used, connect the gray lead to the supply negative dimming lead.

LINE

NEUTRAL

DRIVER ASSEMBLY

BLACK

WHITE

VIOLET

GRAY

© 2020 Cree Lighting, A company of IDEAL INDUSTRIES. All rights reserved. For informational purposes only. Content is subject to change. See www.creelighting.com/warranty for warranty and specifications. Cree ® and the Cree logo are registered trademarks of Cree, Inc. UR2-48™ and UR3-48™ are trademarks of Cree Lighting, A company of IDEAL

INDUSTRIES.

6 of 6 www.creelighting.com

LPN00218X0004A0_A