Schlage MAVIN EP2500 PIM400-485 AD400 GWE NDE Wiring Diagram

Add to My manuals
1 Pages

advertisement

Schlage MAVIN EP2500 PIM400-485 AD400 GWE NDE Wiring Diagram | Manualzz
AC
INPUT
GND
+
-
120
VAC
IP/PoE
GWE
NDE
LOCK
RS485 4000' MAX
PIM400-485
2x18
PIM400485-V2
AD-400
LOCK
UL294
12/24VDC
POWER
SUPPLY
BELDEN 9842 OR EQUIVALENT
AD-400
LOCK
P5
TDA-
GND
BELDEN 9842 OR EQUIVALENT
GND
-
+
BLU/WHT
RS485 4000' MAX
NEU
LINE
UL 294
12/24VDC
SUPPLY
BELDEN 9842
RDA-
UL294
12/24VDC
POWER
SUPPLY
NDE
LOCK
AC
INPUT
BELDEN 9842
SHIELD
BLU/WHT
ORG/WHT
WHT/ORG
SHIELD
ORG/WHT
WHT/ORG
RDB+
TDB+
120
VAC
SHIELD ON COMMUNICATION WIRES, BELDEN 9842, SHOULD CONNECT TO EARTH GROUND AT ONE LOCATION ONLY, EP2500.
WIRING SHOWN REFLECTS WIRING FROM EP2500 TO PIM400-485 AND GWE ONLY. ADDITIONAL WIRING WILL BE REQUIRED AND IS NOT
SHOWN HERE.
IF PLENUM RATED CABLE IS REQUIRED USE BELDEN 82842 OR EQUIVALENT.
UL294 POWER SUPPLIES USED SHOULD NOT BOND EARTH GROUND TO SIGNAL GROUND.
MAVIN EP2500 WILL SUPPORT UP TO SIXTEEN PIM400-485 AND GWE COMBINED ACROSS TWO RS485 DATA LINES WITH NO MORE THAN
EIGHT PIM400-485 AND GWE COMBINED PER RS485 DATA LINE. EACH PIM400-485 IS CAPABLE OF CONTROLLING UP TO SIXTEEN AD400
LOCK AND EACH GATEWAY CAN CONTROL UP TO 10 NDE LOCKS. MAVIN EP2500 CAN HANDLE UP TO SIXTY-FOUR AD400 AND NDE LOCKS
TOTAL COMBINED.
GND
TX+
RX+
TXRX-
NOTE: CONFIGURATION HAS NOT BEEN TESTED BY ALLEGION BUT HAS BEEN REVIEWED AND APPROVED BY MAVIN.
EP2500
2x18
UL294
12/24
POWER
SUPPLY
120
VAC
MAVIN
SMP
-
+
UL 294
12VDC
SUPPLY
DWG NO:
120
VAC
BRENDA DOVE
DRAWN/CHECKED BY:
112492
MAVIN EP2500 WITH PIM400-485/AD400
AND GWE/NDE
GND
TR-
TR+
GND
TR-
TR+
GND
CTS
RTS
TR-
TR+
GND
FLT
GND
TMP
GND
VIN
TB1
MAVIN EP2500
TITLE:
PORT 1
PORT 2
PORT 3
NEU
LINE
UL 294
12/24VDC
SUPPLY
+
-
REV
A

advertisement

Related manuals

advertisement