Schlage Genetec AD400 EP2500 RS485 Wiring Diagram
Below you will find brief information for EP-2500, PIM400-485, AD400 and AD300. This wiring diagram illustrates the connections for the Genetec EP-2500 system with the PIM400-485 interface module and AD400/AD300 locks. It outlines the necessary wiring for power supplies, RS485 communication and the integration with the Synergis Cloud Link Appliance to the Genetec Security Center. Key considerations include proper grounding, cable specifications (BELDEN 9842), and the placement of shorting blocks.
Advertisement
Advertisement
Advertisement
Key features
Illustrates wiring for EP-2500, PIM400-485, and AD400/AD300 locks.
Specifies BELDEN 9842 or equivalent cable is required.
Highlights the importance of earth grounding the communication wire shield.
Details RS485 data line limitations for PIM400-485 and AD300 devices.
Notes UL294 power supply requirements for grounding.
Frequently asked questions
BELDEN 9842 or equivalent cable is recommended.
The shield on communication wires (BELDEN 9842) should connect to earth ground at one location only, EP-2500.
Mercury EP-2500 will support up to sixteen PIM400-485 across two RS485 data lines.
Each PIM400-485 is capable of controlling up to sixteen AD400 locks.