REPOTEC RP-IMC601C30, Industrial Media Converter User manual

Add to my manuals
7 Pages

advertisement

REPOTEC RP-IMC601C30, Industrial Media Converter User manual | Manualzz

User Manual

Industrial Media Converter, with 1 x 100BaseF(X) SC SM 30KM + 1 x 10/100M,

18-36VAC or 12-56 VDC input

FCC MARKING

This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.

Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received; including interference that may cause undesired operation.

CE MARKING

This equipment complies with the requirements relating to electromagnetic compatibility, EN 55032/35 class A for ITE, the essential protection requirement of

Council Directive 2014/30/EC on the approximation of the laws of the Member States relating to electromagnetic compatibility.

Company has an on-going policy of upgrading its products and it may be possible that information in this document is not up-to-date. Please check with your local distributors for the latest information. No part of this document can be copied or reproduced in any form without written consent from the company.

Trademarks:

All trade names and trademarks are the properties of their respective companies.

1

Key Features

 True Mini, hardened design enclosure 59x36x50mm (LxWxD)

 Supports 18V-36VAC, 12V-60VDC or DC Jack socket

 Supports Link Fault Pass through (LFP) function

 Supports Switch Mode and Converter Mode.

 Surge protection diodes on power input.

 ESD protection diodes on RJ-45 port

 Provides Far End Fault function on FX port.

 Provides increased Noise Immunity

 Extended environmental specification -40°C to 75°C

Introduction

This true mini, hardened Industrial Media Converter is designed for critical but space-limited outdoor CAM enclosure. It can be powered by wide range VAC, VDC or external DC power adapter. This unit can be either din-rail or wall mounted, both options are both included. It is an ideal unit for IP surveillance, traffic monitoring and security applications in critical environments. It can tolerate -40°C to 75°C in harsh environments to connect a reliable network.

2

Installation package

This unit can be din-rail mounted or wall-mounted. Din-rail brackets and wall-mount brackets are included.

Power connection

This unit provides a 3 pin terminal block. It can be operated using either VAC or VDC power sources. The VDC power range is from 12VDC to 60VDC, and the VAC power range is from

18VAC to 36VAC. Always make sure your input voltage is within this supported voltage range.

To connect power: Follow the printed polarity for V+, V- and Ground. Connect positive wire to

V+, connect negative wire to V- and also connect neutral wire to ground.

Power connecting procedure:

WARNING -- Always SHUT OFF power source to connect power wire.

WARNING – DO NOT force SFP fiber into SFP housing without removing terminal block.

WARNING -- Any exceeded input voltage will not make this unit function and may damage this unit.

STEP 1 – Pull out 3 pin terminal block.

STEP 2 – Connect wire to V+, V- and Ground.

STEP 3 – Connect SC/SFP/WDM fiber wire to fiber port.

STEP 4 – Plug back 3 pin terminal block to its place.

3

Dip switch function

This unit is equipped with dip switches, located on the front panel marked as SW1. Adjusting the dip switches will change the default function of this unit. This unit has set to manufacturer default as: Switch Mode ON and LFP function OFF.

The table shown as you may change the dip switch setting to your desired environment.

1 2

UP

DIP 1

UP LFP enabled

DOWN LFP disabled (Default)

SW

1

DOWN

DIP 2

UP Converter Mode

DOWN Switch Mode (Default)

LED indicator

PWR (Green)

ON – Power is detected

OFF – Power is not detected

LK/Act (Green)

ON – Fiber port is detected

Flashing – Fiber data is transmitting/receiving

Fiber Port

TX (Amber)

ON – 100M speed is detected

OFF – 10M speed is detected

TX (Green)

On – TX port is detected

Flashing – TX data is transmitting/receiving

4

Specification

IEEE Standard

Data Processing

Flow Control

Jumbo Frame

Architecture

Network Connector

LED Indicators

DIP Switch

Power Protection

Connector Protection

Reserve Polarity Protection

Overload Current Protection

Power Input

IEEE 802.3 10Base-T Ethernet

IEEE 802.3u 100Base-TX Fast Ethernet

IEEE 802.3u 100Base-FX Fast Ethernet

IEEE802.3x Flow Control and Back Pressure

Store and Forward

IEEE 802.3x Flow Control and Back Pressure

9KB

Full wire speed conversion,

Transparent conversion to 802.1Q VLAN tagged packets.

1 x RJ-45 10/100BaseT(X) Auto negotiation,

Auto MDI/MDI-X function, Full/Half duplex

1 x 100M SC Single-Mode 30km

PWR(Green): ON - Power is detected

LK/Act (Green): ON - Fiber is detected

Flashing - Data is transmitting/receiving

RJ-45 port

Green: ON

TX link is detected

Flashing - TX data is transmitting/receiving

Amber: ON - 100M speed is detected

OFF - 10M speed is detected

DIP1: UP

LFP enable

DOWN

LFP disable (Default)

LFP (Link Fault Pass Through)

DIP2: UP - Converter Mode

DOWN - Switch Mode (Default)

Surge protection diodes on power input

ESD protection diodes on TX port

Present

Present

18V-36VAC, 12V-60VDC,

DC Jack terminal cable supported (DC Barrel

Connector)

5

Conformance to UL Standards

Power Consumption

Removable Terminal Block

Operating Temperature

Operating Humidity

Storage Temperature

Housing Design

Case Dimension (L X W X D)

Installation

Certifications

Safety

EMC/EMS

EMI

Vibration

Shock

Free Fall

Use Isolated power supply to conform with UL 508 standard

Full Load: 1.92Watts at 48VDC

3 pin contact terminal block for power input

Wire range: 0.34mm^2 to 2.5mm^2

Solid wire (AWG):12-24/14-22

Stranded wire (AWG): 12-24/14-22

Torque:5lb-In/0.5Nm/0.56Nm

Wire Strip length: 7-8mm

-40°C~75°C

5% to 95% (Non-condensing)

-40°C~85°C

IP40 Design, high graded Aluminum

59 x 36 x 50 mm (L x W x D)

DIN-Rail mounted, Panel Mounted

LVD (EN62368-1)

CE, FCC, EN55032/35 , VCCI

FCC Part 15 Subpart B Class A

EN 60068-2-6

EN 60068-2-27

EN 60068-2-32

6

Housing Dimension (mm)

NOTE:

Housing dimension is for the purpose of showing product Length, Width, Height, din-rail, and terminal block’s position and dimension. Please reference the LED Indicator Page for correct port order.