Daikin BRC51A62 Mode d'emploi
Add to My manuals72 Pages
Daikin BRC51A62 is a wireless remote control for your air conditioner. It offers various modes such as Cool, Heat, Auto, Dry, and Fan. You can set the desired temperature, fan speed, and timer. It also features a Turbo mode for faster cooling and a Quiet mode for reduced noise.
advertisement
▼
Scroll to page 2
of
72
![Daikin BRC51A62 Manual - Remote Control Instructions | Manualzz Daikin BRC51A62 Manual - Remote Control Instructions | Manualzz](http://s1.manualzz.com/store/data/073515822_1-b4051fe3bb3f4fe4dbdc0591805aeb4a-360x466.png)
OPERATING MANUAL Operating Manual Handset Wireless AUTO ON 12 OFF 12 12 DRY AUTO COOL TURBO QUIET MODE DELAY TIMER HEAT FAN SWING SLEEP SWING TIMER TIMER FAN AM PM F C SET TEMP. TURBO ON English MON TUE WED THU FRI SAT SUN ALL OVERRIDE OFF QUIET Mode D’emploi Combiné Câblé Français Bedienungsanleitung Verdrahtetes Handgerät Deutsch SLEEP ON / OFF Manuale Di Funzionamento Ricevitore senza fili Italiano Manual De Instrucciones Auricular Inalámbrico Español Руководство По Зксплуатации Беспроводное Дистанционное Управление Pycckий Kullanım Kılavuzu Kablosuz Kumanda Türkçe OM-SLM9-0911(1)-DAIKIN Part No.: R08019037014A i BRC51A61/62 Controller Indication AUTO ON 12 OFF 12 MON TUE WED THU FRI SAT SUN ALL OVERRIDE 12 DRY 3 2 1 MODE 10 9 11 8 NO AUTO COOL TURBO QUIET DELAY TIMER HEAT FAN SWING SLEEP F C SET TEMP. TURBO SWING TIMER TIMER ON AM PM OFF FAN 4 5 QUIET SLEEP ON / OFF KEY 6 7 12 13 FUNCTION 1. MODE Select operating Modes control (Cool/ Heat/ Auto/ Dry/ Fan) 2. TURBO Activate/deactivate Turbo function 3. SWING Activate/deactivate Swing control Hold Key to change Swing Mode 4. QUIET Activate/deactivate Quiet function 5. SET TEMP UP Increase set temperature in °C or °F 6. SET TEMP DOWN Decrease set temperature in °C or °F 7. SLEEP Activate/deactivate Sleep function 8. OFF TIMER Enable/disable the Event 1 and 2 OFF TIMER setting mode 9. ON TIMER Enable/disable the Event 1 and 2 ON TIMER setting mode 10. DELAY TIMER Activate/deactivate delay timer 11. FAN Select Fan speeds control (Auto/ High/ Med/ Low) 12. ON/OFF On/Off the unit with overriding all the timer settings 13. REAL TIME CLOCK (RTC) Enable/disable the Real Time Clock (RTC) setting mode NOTE: Turbo and quiet function are for selected models only. ii MODE Button Press the MODE button to switch operation from COOL, HEAT*, AUTO*, DRY*, FAN. Check the display to see in which mode the control is set. *HEAT, AUTO and DRY are available for selected models only. 1.2 TURBO Fan Speed Press the TURBO key once to activate Turbo fan speed. Turbo symbol will be shown. To disable Turbo fan speed and back to previous fan speed, press the Turbo key once again. If user presses the FAN button or QUIET button or turn off the unit, the turbo speed will be disabled. This speed is only valid during COOL and HEAT mode for selected models. 1.3 Automatic air swing • Press the SWING button to activate the automatic air swing function. • To distribute the air to a specific direction, press the SWING button and wait until the louver move to the desired direction and press the button once again. Swing mode selection method (model dependent) • Press SWING ( ) button for 4 seconds to enter field setting mode. While in field setting mode, it will only show SWING MODE ( ). • Press temperature and button to select SWING MODE ( ) rotation from Swing Mode 1 to Swing Mode 3. • There are 3 different SWING MODE, which are: Swing mode 1 Swing mode 2 Swing mode 3 SWING MODE will not activate unless SWING is activated. Swing is indicated by the logo: • If no mode changes within 4 seconds, unit will operate according to the selected SWING MODE ( 1.4 ). QUIET Fan Speed Press the QUIET key once to activate Quiet fan speed. QUIET symbol will be shown. To disable Quiet fan speed and back to previous fan speed, press the QUIET key again. If user presses the FAN button or TURBO button or turn off the unit, the quiet speed will be disabled. This speed is only valid during COOL and HEAT mode for selected models. 1.5 “ ” or “ ” Set Temperature Button Press the temperature button and set the temperature of your choice by pressing “ ” or “ ” button once, temperature changes by 1°C or 1°F. The default temperature setting range is from 16°C to 30°C (60°F to 86°F). When the Option 20 - 30ºC is set, the temperature range limit is set to 20ºC to 30ºC (68°F to 86°F). Pressing both keys simultaneously will toggle the temperature setting between ºC and ºF. No temperature setting is allowed during FAN mode (No set temp display). There is no room temperature display. 1.6 SLEEP Function Press the SLEEP button to activate the sleep mode. SLEEP function is not available in DRY mode and FAN mode. 1.7 “ON TIMER” and “OFF TIMER” The unit has 2-event timer, namely Timer 1 and Timer 2, each event has an ON TIMER and an OFF TIMER. The key press activity for Timer ON and Timer OFF is shown on Table 1.1 1 Original Instruction 1.1 ENGLISH OPERATING INSTRUCTION Table 1.1: Timer ON and Timer OFF key press and event sequence. TIMER ON KEY TIMER OFF KEY ON Timer 1 ON Timer 2 OFF Timer 1 OFF Timer 2 Deactivated Deactivated Deactivated Deactivated Activated Deactivated Activated Deactivated Deactivated Activated Deactivated Activated Activated Activated Activated Activated All timers are event-triggered timers and can be overridden by the ON/OFF button and Override function. Set Event 1 and Event 2 Timers Process for Timer ON and Timer OFF is the same. 1. Press and hold Timer ON/OFF key for 3 seconds to go into timer setting mode. (Icon ON 1 or OFF 1 will blink) 2. Press UP or DOWN to select Timer 1 or Timer 2 to set. (‘1’ blinking indicate that Timer 1 is currently selected, ‘2’ blinking indicate that Timer 2 is currently selected) 3. Press Timer ON/OFF key again to confirm. (Day will blink next) 4. Press UP or DOWN to select the day. 5. Press Timer ON/OFF key again to confirm the day. (Hour will blink next) 6. Press UP or DOWN to change the hour. 7. Press Timer ON/OFF key again to confirm the hour. (Minute will blink next) 8. Press UP or DOWN to change the minute. 9. Press Timer ON/OFF key again to confirm the minute. Each timer (Timer 1 ON or Timer 1 OFF or Timer 2 ON or Timer 2 OFF) will only be set separately after all 7 steps, if there is no key operation for 5 seconds during setting the timer, it will automatically exits from setting mode and no changes will be made. ON/OFF timer will be checked every 1 minute. It is not advisable to set ON TIMER and OFF TIMER to have same values. Shall these occur, the effective timer will be treated with priority as stated in Table 1.2. Example: ON TMR 2 settings: DAY – TUE, TIMER – 5.00pm OFF TMR 1 settings: DAY – TUE, TIMER – 5.00pm Outcome when RTC reaches 5.00pm on TUE: – when unit is on, no respond. – when unit is off, unit will trigger to on. Table 1.2: Timer Priority Priority Timer 1 (Highest) ONTMR2 2 OFFTMR2 3 ONTMR1 4 (Lowest) OFFTMR1 Upon IR reception, IR wireless remote controller will override ON TIMER 2 and OFF TIMER 2 settings. 2 DELAY TIMER Function Press the DELAY TIMER key once will activate the delay timer function for 1 hour. An indicator “OVERRIDE” will show on the LCD. Press the same key again will increase the setting to 2 hours. An indicator “OVERRIDE” will be shown. Subsequent press will deactivate the delay timer function. After the delay timer is completed, the delay timer function is deactivated and the logo is OFF. All other timers will be resumed. 1.9 FAN Speed Function Fan speed can be changed via pressing the FAN key: Low > Med > High > Auto > *FAN speed is not available in DRY mode. 1.10 ON/OFF Button Starting Operation: – Press the ON/OFF button, the LCD will show full display and the unit is turned on. Stopping Operation: – Press the ON/OFF button, the LCD will show real time clock only and the unit is turn off. 1.11 Power up Settings The unit will start up with main board’s last state setting during power up. If last state information is not available, the unit will use the default settings. The default settings are as below: Unit: Mode: Fan Speed: RTC: Swing: Swing Mode: Timers: Turbo: Quiet: Sleep: Override: Off Cool High 12:00AM, MONDAY Off Standard Disable Disable Off Off Disable 1.12 Real-time Clock (RTC) Display RTC is shown on screen during the unit ON or OFF except for power failure or error code. Set RTC Setting 1. Press RTC key one time will activate RTC setting mode. (Day will blink) 2. Press UP or DOWN to select the day. 3. Press RTC again to confirm the day. (Hour will blink next) 4. Press UP or DOWN to change the hour. 5. Press RTC again to confirm the hour. (Minute will blink next) 6. Press UP or DOWN to change the minute. 7. Press RTC again to confirm the minute. RTC will only be set after all 7 steps, if there is no key operation for 5 seconds during setting the RTC, it will automatically exits from setting mode and no changes will be made on the setting. 1.13 Key Lock These key lock function inhibits any setting change. Press and hold both TURBO and QUIET keys for 5 seconds will activate/deactivate the key lock function; “KEYLOCK” will be shown/disappear on LCD. Upon all the keys are locked, only ON/OFF, TURBO and QUIET (to unlock) can be pressed. 3 ENGLISH 1.8 1.14 Battery Backup Battery backup is used to retain the RTC and 7-days programmable timer settings during power down for a minimum of 1 month continuous for every new set of battery installed. For unit without battery backup, the default setting will be 12:00am on Monday and timer clear during power up. 1.15 Error Indicator If any abnormal condition detected, an error code will be shown. Error code is displayed by using RTC segments (blink), which mean whenever there is error occur, RTC will not be shown instead of the error code. The format for the error code will be as following: DX Error Code Error Description Room Sensor Open or Short E1 Indoor Coil Sensor Open E2 Outdoor Coil Sensor Open E3 Compressor Overload/Indoor Coil Sensor Short/Outdoor Coil Sensor Short E4 Low Refrigerant Charge/Gas Leak/Outdoor Abnormal E5 Water Pump Fault E6 Outdoor Coil Sensor Exist (MS model) E7 Hardware Error (Tact Switch Pin Short) E8 Indoor Fan Feedback Error E9 EEPROM Error EE CW Error Code Error Description Room Sensor Open or Short E1 Pipe Water Sensor Open or Short E2 Pipe Water Temperature Poor E4 Pipe Water Temperature Bad/Fault E5 Water Pump Error E6 Hardware Error (Tact Switch Pin Short) E8 Indoor Fan Feedback Error E9 Fault Diagnosis (for inverter only) If there is any abnormal condition detected, SLM9 wired controller will blink the error code ERROR CODE MEANING 00 NORMAL A1 INDOOR PCB ERROR A3 DRAIN PUMP ABNORMAL A5 ANTIFREEZE (COOLING)/HEAT EXCHANGER OVERHEAT (HEATING) A6 INDOOR FAN MOTOR ABNORMAL AH ELECTRICAL AIR CLEANER ABNORMAL C4 INDOOR HEAT EXCHANGER (1) THERMISTOR SHORT/OPEN C5 INDOOR HEAT EXCHANGER (2) THERMISTOR SHORT/OPEN C7 LOUVER LIMIT SWITCH ERROR C9 INDOOR ROOM THERMISTOR SHORT/OPEN 4 MEANING E1 OUTDOOR PCB ERROR E3 HIGH PRESSURE PROTECTION E4 LOW PRESSURE PROTECTION E5 COMPRESSOR MOTOR LOCK/COMPRESSOR OVERLOADED E6 COMPRESSOR START-UP ERROR E7 OUTDOOR DC FAN MOTOR LOCK E8 AC INPUT OVER CURRENT E9 EXV ERROR EA 4 WAY VALVE ERROR F3 DISCHARGE PIPE OVERHEAT F6 HEAT EXCHANGER OVERHEAT HO COMPRESSOR SENSOR SYSTEM ERROR H3 HIGH PRESSURE SWITCH ERROR H6 COMPRESSOR FEEDBACK DETECTION ERROR H7 FAN MOTOR OVERLOADED/OVERCURRENT/SENSOR ABNORMAL H8 AC CURRENT SENSOR ERROR H9 OUTDOOR AIR THERMISTOR SHORT/OPEN J1 PRESSURE SENSOR ERROR J3 COMPRESSOR DISCHARGE PIPE THERMISTOR SHORT/OPEN/MISPLACED J5 SUCTION PIPE THERMISTOR SHORT/OPEN J6 OUTDOOR HEAT EXCHANGER THERMISTOR SHORT/OPEN J7 SUBCOOLING HEAT EXCHANGER THERMISTOR SHORT/OPEN J8 LIQUID PIPE THERMISTOR SHORT/OPEN J9 GAS PIPE THERMISTOR SHORT/OPEN L1 INVERTER OUTDOOR PCB ERROR L3 OUTDOOR CONTROL BOX OVERHEAT L4 HEAT SINK OVERHEAT L5 IPM ERROR/IGBT ERROR L8 INVERTER COMPRESSOR OVERCURRENT L9 COMPRESSOR OVERCURRENT PREVENTION LC COMMUNICATION ERROR (OUTDOOR CONTROL PCB AND INVERTER PCB) P1 OPEN PHASE OR VOLTAGE UNBALANCE P4 HEAT SINK THERMISTOR SHORT/OPEN PJ CAPACITY SETTING ERROR U0 INSUFFICIENT GAS U2 DC VOLTAGE OUT OF RANGE U4 COMMUNICATION ERROR U7 COMMUNICATION ERROR (OUTDOOR CONTROL PCB AND IPM PCB) UA INSTALLATION ERROR UF PIPING & WIRING INSTALLATION MISMATCH/WRONG WIRING/INSUFFICIENT GAS UH ANTIFREEZE (OTHER ROOMS) 5 ENGLISH ERROR CODE 2.0 HARDWARE SETTING The unit has 2 jumpers option to control the board function. Table 2.0: Summary of Hardware Settings OPTION With Jumper Without Jumper Set Temp. Range Set temp. range from 20°C – 30°C Set temp. range from 16°C – 30°C (Default) TURBO_QUIET Disable turbo and quiet fan speed (Default) Enable turbo and quiet fan speed * Only applicable to model with built in Turbo or Quiet features. 3.0 INSTALLATION 3.1 Accessories The following accessories are included together with this manual. If any part is missing, contact your dealer immediately. 1. Remote controller 2. Wooden screw (2 pieces) & machine screw (2 pieces) 3. Instruction manual 4. Battery 3.2 Step-by-step guide I. Open the clip on the top of the controller first follow by the bottom clip. Remove the top case of the controller from the bottom case. II. Fix the bottom case to the wall with the 2 screw provided. Then insert the connection wire through the slot on the upper center case as shown. III. Insert back the bottom clip first then snap the upper part shut. Connection wires LCD Remote (Top case) MOD E TURB O SWIN G DELA Y TIMER QUIE T TIMER TIMER FAN SLEE P ON / OFF 2 x Wooden screw 6 LCD Remote (Bottom case) MEMO BRC51A61/62 Indication De Contríleur AUTO ON 12 OFF 12 MON TUE WED THU FRI SAT SUN ALL OVERRIDE 12 DRY MODE 10 9 11 8 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. COOL TURBO QUIET 3 2 1 NO 1. MODE AUTO DELAY TIMER HEAT FAN SWING SLEEP F C SET TEMP. TURBO SWING TIMER TIMER ON AM PM OFF FAN QUIET SLEEP ON / OFF TOUCHE 4 5 6 7 12 13 FONCTION Sélectionnez la commande des modes de fonctionnement (Cool (Froid) / Heat (Chauffage) / Auto / Dry (Sec) / Fan (Ventilation) TURBO Activez/désactivez la fonction Turbo SWING Activez/désactivez la commande d’oscillation Maintenir la touche enfoncée pour changer de mode d’oscillation QUIET Activez/désactivez la fonction Silence SET TEMP UP Augmentez la température réglée en °C ou en °F SET TEMP DOWN Réduisez la température réglée en °C ou en °F SLEEP Activez/désactivez la fonction Sommeil OFF TIMER Activez/désactivez le mode de réglage MINUTERIE DE MISE EN ARRÊT, événements 1 et 2 ON TIMER Activez/désactivez le mode de réglage MINUTERIE DE MISE EN MARCHE, événements 1 et 2 DELAY TIMER Activer/désactiver la programmation de mise en marche/arrêt FAN Sélectionnez la commande des vitesses du ventilateur (Auto / High (Rapide)/ Med (Moyen)/ Low (Lent)) ON/OFF Appuyez sur la touche On/Off de l’unité pour annuler tous les réglage de la minuterie MODE DE RÉGLAGE DE Activez/désactivez le mode de réglage de l’horloge temps réel L’HORLOGE TEMPS RÉEL (HTR) (HTR) REMARQUE : Les fonctions turbo et silence ne sont disponibles que sur les modèles sélectionnés. i INSTRUCTIONS D’UTILISATION Appuyez sur le bouton MODE pour alterner entre COOL (FROID), HEAT* (CHAUD), AUTO*, DRY* (SEC), FAN (VENTILATION). Vérifiez l’affichage pour voir sur quel mode est réglée l’unité. Les fonctions *HEAT (CHAUD), AUTO et DRY (SEC) ne sont disponibles que pour les modèles sélectionnés. 1.2 Vitesse de ventilation TURBO Appuyez sur la touche TURBO une fois pour activer la vitesse de ventilation TURBO. Le symbole du turbo s’affiche. Pour désactiver la vitesse de ventilation Turbo et revenir à la vitesse de ventilation précédente, appuyez à nouveau sur la touche Turbo. Si l’utilisateur appuie sur la touche FAN (VENTILATEUR) ou QUIET (SILENCE) ou s’il éteint l’unité, la vitesse turbo est désactivée. Cette vitesse n’est valable qu’en modes COOL (FROID) et HEAT (CHAUD) pour les modèles sélectionnés. 1.3 Oscillation automatique de la ventilation • Appuyez sur le bouton SWING pour activer la fonction d’oscillation automatique de la ventilation. • Pour orienter la ventilation dans une direction précise, appuyez sur le bouton SWING , attendez ensuite que le volet de ventilation souffle dans la direction désirée puis appuyez de nouveau sur le bouton. Méthode de sélection du mode Swing (dépendant du modèle) • Appuyez sur le bouton SWING ( ) pendant 4 secondes pour entrer dans le mode de réglage du champ. En mode de réglage local, seul le mode d’oscillation SWING MODE ( ) est affiché. • Appuyez sur le bouton de température et pour sélectionner la rotation du SWING MODE ( ) depuis le Mode Swing 1 au Mode Swing 3. • Les 3 différents modes d’oscillation (SWING MODE) suivants sont disponibles : Mode d’oscillation 1 Mode d’oscillation 2 Mode d’oscillation 3 Le mode d’oscillation (SWING MODE) ne sera pas activé, sauf si la fonction d’oscillation (SWING) est activée. L’oscillation est indiquée par le logo : • Si aucun mode ne change dans les 4 secondes, l’appareil fonctionnera selon le SWING MODE ( ) sélectionné. 1.4 Vitesse de ventilation QUIET (SILENCE) Appuyez sur la touche QUIET (SILENCE) une fois pour activer la vitesse de ventilation silence. Le symbole QUIET (SILENCE) s’affiche. Pour désactiver la vitesse de ventilation Silence et revenir à la vitesse de ventilation précédente, appuyez à nouveau sur la touche QUIET (SILENCE). Si l’utilisateur appuie sur la touche FAN (VENTILATEUR) ou TURBO ou s’il éteint l’unité, la vitesse silence est désactivée. Cette vitesse n’est valable qu’en modes COOL (FROID) et HEAT (CHAUD) pour les modèles sélectionnés. 1.5 Le Bouton du Réglage de la Température « » ou « » Appuyez sur la touche de la température et programmez la température de votre choix en appuyant une fois sur « » ou « », la température change par incréments de 1°C ou 1°F. La plage de températures par défaut s’étend de 16°C à 30°C (60°F à 86°F). Lorsque l’option 20 – 30°C est définie, la limite de la plage de température est définie entre 20°C et 30°C (68°F à 86°F). Appuyez simultanément sur les deux touches pour afficher les températures en °C ou en °F. Aucun réglage de température n’est autorisé en mode FAN (VENTILATEUR) (Aucun affichage de température réglée). L’espace est insuffisant pour afficher la température. 1.6 FONCTION SLEEP (SOMMEIL) Appuyez sur la touche SLEEP (SOMMEIL) pour activer le mode de nuit. La fonction SLEEP (SOMMEIL) n’est pas disponible en mode DRY (SEC) ni en mode FAN (VENTILATEUR). 1.7 « ON TIMER » ou « OFF TIMER » L’unité est dotée de 2 minuteries d’événements, à savoir Minuterie 1 et Minuterie 2, chacune offrant une minuterie de mise en marche (ON TIMER) et une de mise en arrêt (OFF TIMER). L’action des touches TIMER ON (MINUTERIE DE MISE EN MARCHE) et TIMER OFF (MINUTERIE DE MISE EN ARRET) est illustrée dans le Tableau 1,1. 1 FRANÇAIS Bouton de MODE Traduction des instructions d’origine 1.1 Tableau 1,1 : Action des touches de minuterie TIMER ON (MINUTERIE DE MISE EN MARCHE) et de TIMER OFF (MINUTERIE DE MISE EN ARRET) et séquence d’événements. TOUCHE TIMER ON TOUCHE TIMER OFF Minuterie 1 ON Minuterie 2 ON Minuterie 1 OFF Minuterie 2 OFF Désactivée Désactivée Désactivée Désactivée Activée Désactivée Activée Désactivée Désactivée Activée Désactivée Activée Activée Activée Activée Activée Toutes les minuteries sont des minuteries déclenchées par des événements et peuvent être annulées par la touche ON/OFF et la fonction prioritaire. Fixez les minuteries des événements 1 et 2 Le procédé est le même pour TIMER ON (MINUTERIE DE MISE EN MARCHE) et TIMER OFF (MINUTERIE DE MISE EN ARRET). 1. Maintenez la touche TIMER ON/OFF (MINUTERIE DE MISE EN MARCHE/ARRET) pendant 3 secondes pour entrer en mode de réglage de la minuterie. (L’icône ON 1 ou OFF 1 clignote) 2. Appuyez sur UP (HAUT) ou DOWN (BAS) pour sélectionner Minuterie 1 ou Minuterie 2 et faire le réglage. (Le « 1 » clignotant indique que la Minuterie 1 est actuellement sélectionnée, le « 2 » clignotant indique que la Minuterie 2 est actuellement sélectionnée) 3. Appuyez à nouveau sur la touche TIMER ON/OFF (MINUTERIE DE MISE EN MARCHE/ARRET) pour confirmer. (Le jour clignote ensuite) 4. Appuyez sur UP (HAUT) ou sur DOWN (BAS) pour sélectionner le jour. 5. Appuyez à nouveau sur la touche TIMER ON/OFF (MINUTERIE DE MISE EN MARCHE/ARRET) pour confirmer le jour. (L’heure clignote ensuite) 6. Appuyez sur UP (HAUT) ou sur DOWN (BAS) pour changer l’heure. 7. Appuyez à nouveau sur la touche TIMER ON/OFF (MINUTERIE DE MISE EN MARCHE/ARRET) pour confirmer l’heure. (Les minutes clignotent ensuite) 8. Appuyez sur UP (HAUT) ou sur DOWN (BAS) pour changer les minutes. 9. Appuyez à nouveau sur la touche TIMER ON/OFF (MINUTERIE DE MISE EN MARCHE/ARRET) pour confirmer les minutes. Chaque minuterie (Minuterie 1 ON (MARCHE) ou Minuterie 1 OFF (ARRET) ou Minuterie 2 ON (MARCHE) ou Minuterie 2 OFF (ARRET)) ne sera réglée séparément qu’après les 7 étapes, si aucune touche n’est actionnée pendant 5 secondes au cours du réglage de la minuterie, le mode de réglage sera automatiquement désactivé et aucune modification ne sera effectuée. Le TIMER ON/OFF (MINUTERIE DE MISE EN MARCHE/ARRET) sera vérifié toutes les 1 minute. Il est déconseillé de régler le ON TIMER (MINUTERIE DE MISE EN MARCHE) et le OFF TIMER (MINUTERIE DE MISE EN ARRET) sur les mêmes valeurs. Si cela se produit, la minuterie effective sera traitée en priorité, comme indiqué dans le Tableau 1,2. Exemple : Réglages ON TMR 2 (MINUTERIE DE MISE EN MARCHE 2) : DAY – TUE, TIMER – 5.00pm Réglages OFF TMR 1 (MINUTERIE DE MISE EN ARRET 1) : DAY – TUE, TIMER – 5.00pm Résultat lorsque l’HTR atteint 17h00 le TUE (MAR) : – si l’unité est en marche, aucune réaction. – si l’unité est à l’arrêt, elle se met en marche. Tableau 1,2 : Priorité de minuterie Priorité Minuterie 1 (La plus élevée) ONTMR2 2 OFFTMR2 3 ONTMR1 4 (La plus faible) OFFTMR1 Sur réception de rayons IR, la télécommande sans fil IR prend la priorité sur les réglages ON TIMER 2 (MINUTERIE DE MISE EN MARCHE 2) et OFF TIMER 2 (MINUTERIE DE MISE EN ARRET 2). 2 Fonction DELAY TIMER Appuyez sur la touche DELAY TIMER une fois pour activer la fonction de programmation de mise en marche/arrêt pendant 1 heure. Un indicateur « OVERRIDE » s’affiche sur l’écran LCD. Appuyez de nouveau sur la même touche pour augmenter le réglage à 2 heures. Un indicateur « OVERRIDE » s’allumera. Appuyer de nouveau désactivera la fonction de programmation de mise en marche/arrêt. Une fois la programmation de mise en marche/arrêt terminée, la fonction de programmation de mise en marche/arrêt est désactivée et le logo disparaît. Toutes les autres minuteries seront reprises. 1.9 Fonction de vitesse FAN (VENTILATEUR) La vitesse de ventilation peut être changée en appuyant sur la touche FAN (VENTILATEUR) : Lent > Moyen > Rapide > Auto > *La vitesse FAN (VENTILATEUR) n’est pas disponible en mode DRY (SEC). 1.10 Bouton ON/OFF (MARCHE’/ARRÊT) Mise en marche : – Appuyez sur la touche ON/OFF (MARCHE/ARRET), l’écran LCD s’affiche intégralement et l’unité est mise en marche. Mise en arrêt : – Appuyez sur la touche ON/OFF (MARCHE/ARRET), l’écran LCD affiche l’horloge temps réel et l’unité est mise à l’arrêt. 1.11 Réglages de mise sous tension L’unité démarre en conservant le dernier réglage de la carte principale pendant la mise sous tension. Si les dernières informations ne sont pas disponibles, l’unité utilisera les réglages par défaut. Les réglages par défaut sont les suivants : Unité : Mode : Vitesse du ventilateur : RTC: Oscillation : Mode d’oscillation : Minuteries : Turbo : Silence : Mise en sommeil : Prioritaire : Arrêt Refroidissement Élevé 12:00AM, MONDAY Arrêt Standard Désactiver Désactiver Arrêt Arrêt Désactiver 1.12 Affichage de l’horloge temps réel (HTR) L’HTR est affichée à l’écran lorsque l’unité et en marche ou à l’arrêt, sauf en cas de panne d’électricité ou de code d’erreur. Définir le réglage de l’HTR 1. Pressez la touche HTR une fois pour activer le mode de réglage HTR. (Le jour clignote) 2. Appuyez sur UP (HAUT) ou sur DOWN (BAS) pour sélectionner le jour. 3. Appuyez à nouveau sur HTR pour confirmer le jour. (L’heure clignote ensuite) 4. Appuyez sur UP (HAUT) ou sur DOWN (BAS) pour changer l’heure. 5. Appuyez à nouveau sur HTR pour confirmer l’heure. (Les minutes clignotent ensuite) 6. Appuyez sur UP (HAUT) ou sur DOWN (BAS) pour changer les minutes. 7. Appuyez à nouveau sur HTR pour confirmer les minutes. L’HTR ne sera réglée séparément qu’après les 7 étapes, si aucune touche n’est actionnée pendant 5 secondes au cours du réglage de la minuterie, le mode de réglage sera automatiquement désactivé et aucune modification ne sera effectuée. 1.13 Verrouillage de touches La fonction de verrouillage de touches sert à empêcher tout changement de réglage. Maintenez les touches TURBO et QUIET (SILENCE) enfoncées pendant 5 secondes pour activer/désactiver la fonction de verrouillage de touches : « KEYLOCK » (VERROUILLAGE DE TOUCHE) s’affiche/disparaît de l’écran LCD. Dès que la totalité des touches est verrouillée, seules les touches ON/OFF (MARCHE/ARRET), TURBO et QUIET (SILENCE) (pour déverrouiller) peuvent être pressées. 3 FRANÇAIS 1.8 1.14 Batterie de secours La batterie de secours sert à conserver l’HTR et les réglages de minuterie programmable sur 7 jours quand l’alimentation est coupée, pendant au minimum 1 mois d’affilée pour chaque nouveau jeu de piles installées. Pour les unités sans batterie de secours, le réglage par défaut est de 12:00 le lundi, et la minuterie est effacée au démarrage. 1.15 Indicateur d'erreur Si une condition anormale est détectée, un code d’erreur s’affiche. Le code d’erreur s’affiche à la place des segments de l’HTR (clignotants), ce qui signifie que dès qu’une erreur survient, l’HTR ne s’affiche pas en plus du code d’erreur. Le format du code d’erreur sera le suivant : Code d’erreur DX Description d’erreur Capteur intérieur ouvert ou faible Capteur à bobine intérieur ouvert Capteur à bobine extérieur ouvert Surcharge du compresseur/Capteur à bobine intérieur faible/Capteur à bobine extérieur faible Charge de fluide frigorigène à faible/Fuite de gaz/Extérieur anormale Erreur de pompe à eau Capteur à bobine extérieur existant (modèle MS) Erreur matérielle (Broche de commutation discrète faible) Erreur de retour du ventilateur de l’unité intérieure Erreur EEPROM E1 E2 E3 E4 E5 E6 E7 E8 E9 EE Code d’erreur CW Description d’erreur Capteur intérieur ouvert ou faible Capteur de la conduite d’eau ouvert ou en court-circuit Température de la conduite d'eau faible Température de la conduite d'eau mauvaise/erronée Erreur de la pompe à eau Erreur matérielle (Broche de commutation discrète faible) Erreur de retour du ventilateur de l’unité intérieure E1 E2 E4 E5 E6 E8 E9 Fau daignostics (pour modèle à inverseur seulement) S’il y a une anomalie détectée, le contrôleur câblé SLM9 va clignoter le code d’erreur CODE D’ERREUR 00 A1 A3 A5 A6 AH C4 C5 C7 C9 SIGNIFICATION NORMAL ERREUR PCB DANS LA SECTION INTÉRIEURE ANOMALIE DE LA POMPE DE VIDANGE ANTIGEL (REFROIDISSEMENT) / ÉCHANGEUR DE CHALEUR DE SURCHAUFFE(CHAUFFAGE) ANOMALIE SUR LE VENTILATEUR D’INTÉRIEUR ANOMALIE DU FILTRE À AIR ÉLECTRIQUE THERMISTOR DE L'ÉCHANGEUR THERMIQUE INTÉRIEUR (1) EN COURT-CIRCUIT/OUVERT THERMISTOR DE L'ÉCHANGEUR THERMIQUE INTÉRIEUR (2) EN COURT-CIRCUIT/OUVERT ERREUR DE L’INTERRUPTEUR DE LIMITE D’AILETTE COURT-CIRCUIT/OUVERTURE DANS LE THERMISTOR DE PIÈCE INTÉRIEURE 4 CODE D’ERREUR J3 J5 J6 J7 J8 J9 L1 L3 L4 L5 L8 L9 LC P1 P4 PJ U0 U2 U4 U7 UA UF UH ERREUR DE CARTE EXTÉRIEURE PROTECTION HAUTE PRESSION PROTECTION BASSE PRESSION VERROU DU MOTEUR DU COMPRESSEUR /COMPRESSEUR SURCHARGÉ ERREUR DE DÉMARRAGE DU COMPRESSEUR VERROU DU MOTEUR DE VENTILATEUR CC EXTÉRIEUR SURINTENSITÉ D’ENTRÉE CA ERREUR EXV ERREUR DE VANNE À 4 VOIES TUYAUTERIE DE VIDANGE DE SURCHAUFFE ÉCHANGEUR DE CHALEUR DE SURCHAUFFE ERREUR DU SYSTÈME DE CAPTEUR DU COMPRESSEUR ERREUR DE L’INTERRUPTEUR HAUTE PRESSION ERREUR DE DÉTECTION DE L’ALIMENTATION DU COMPRESSEUR SURCHARGE/SURINTENSITÉ DU MOTEUR DU VENTILATEUR/ANOMALIE DU CAPTEUR ERREUR DU CAPTEUR DE COURANT CA THERMISTANCE À AIR EXTÉRIEUR EN COURT-CIRCUIT/OUVERT ERREUR DU CAPTEUR DE PRESSION THERMISTANCE DE LA TUYAUTERIE DE VIDANGE DU COMPRESSEUR EN COURT-CIRCUIT/ OUVERTE/ MAL POSITIONNÉE COURT-CIRCUIT/OUVERTURE DANS LE THERMISTOR DU TUYAU D’ASPIRATION THERMISTANCE D’ÉCHANGEUR DE CHALEUR EXTÉRIEUR EN COURT-CIRCUIT/OUVERT COURT-CIRCUIT/OUVERTURE DANS LE THERMISTOR DE L’ÉCHANGEUR THERMIQUE DE SOUS- REFROIDISSEMENT THERMISTANCE DE LA TUYAUTERIE DU LIQUIDE EN COURT-CIRCUIT/OUVERTE THERMISTANCE DE LA TUYAUTERIE DE GAZ EN COURT-CIRCUIT/OUVERTE ERREUR PCB EXTÉRIEURE DE L’INVERSEUR BOÎTIER DE COMMANDE EXTÉRIEUR DE SURCHAUFFE DISSIPATEUR THERMIQUE DE SURCHAUFFE ERREUR IPM /ERREUR IGBT SURINTENSITÉ DU COMPRESSEUR DE L’INVERSEUR PRÉVENTION DE SURINTENSITÉ DU COMPRESSEUR ERREUR DE COMMUNICATION (PCB DE LA COMMANDE EXTÉRIEURE ET PCB DE L’INVERSEUR) PHASE OUVERTE OU DÉSÉQUILIBRE DE TENSION THERMISTANCE DE DISSIPATEUR DE CHALEUR EN COURT-CIRCUIT/OUVERT ERREUR DE RÉGLAGE DE LA CAPACITÉ INSUFFISANCE DE GAZ TENSION CC HORS PLAGE ERREUR DE COMMUNICATION ERREUR DE COMMUNICATION (CARTE DE COMMANDE ET CARTE IPM) ERREUR D’INSTALLATION MAUVAISE CORRESPONDANCE DANS L’INSTALLATION DU CÂBLAGE ET DE LA TUYAUTERIE/ MAUVAIS CÂBLAGE/INSUFFISANCE EN GAZ ANTIGEL (AUTRES PIÈCES) 5 FRANÇAIS E1 E3 E4 E5 E6 E7 E8 E9 EA F3 F6 HO H3 H6 H7 H8 H9 J1 SIGNIFICATION 2.0 RÉGLAGE MATÉRIEL L’unité bénéficie de 2 fonctions de cavaliers pour contrôler le fonctionnement du tableau. Tableau 2,0 : Récapitulatif des réglages matériels OPTION Avec cavalier Sans cavalier Régler plage de temp. Régler plage de temp. de 20°C à 30°C Régler plage de temp. de 16°C à 30°C (Valeur par défaut) TURBO_QUIET Désactiver le turbo et la vitesse de ventilation silence (Valeur par défaut) Activer le turbo et la vitesse de ventilation silence * Seulement applicable au modèle avec fonctions Turbo ou Silence intégrées. 3.0 INSTALLATION 3.1 Accessoires Les accessoires suivants sont compris avec ce manuel. S’il manque des éléments, veuillez contacter votre concessionnaire immédiatement. 1. Télécommande 2. Vis à bois (2 vis) & Vis de l’unité (2 vis) 3. Manuel d’utilisation 4. Pile 3.2 Guide Détaillé I. Ouvrez d’abord l’attache du dessus du contrôleur puis l’attache du bas. Retirez l’enveloppe supérieure du contrôleur de l’enveloppe inférieure. II. Fixez l’enveloppe inférieure sur le mur avec les 2 vis fournies. Insérez ensuite le fil de connexion à travers la fente sur la partie centrale supérieure de l’enveloppe, comme dans l’illustration. III. Réinsérez d’abord l’attache du bas puis clipsez la partie supérieure pour fermer. Fils de raccordement Télécommande LCD (boîtier supérieur) MOD E TURB O SWIN G DELA Y TIMER QUIE T TIMER TIMER FAN SLEE P ON / OFF 2 x Vis à bois Télécommande LCD (Boîtier inférieure) 6 LE MÉMO BRC51A61/62 Controller-Anzeige AUTO ON 12 OFF 12 MON TUE WED THU FRI SAT SUN ALL OVERRIDE 12 DRY 3 2 1 MODE 10 9 11 8 NO 1. MODE AUTO COOL TURBO QUIET DELAY TIMER HEAT FAN SWING SLEEP SWING TIMER TIMER OFF FAN TASTE 2. 3. TURBO SWING 4. 5. 6. 7. 8. QUIET SET TEMP UP SET TEMP DOWN SLEEP OFF TIMER 9. ON TIMER 10. 11. DELAY TIMER FAN 12. 13. ON/OFF REELLE ZEITUHR (RTC) F C SET TEMP. TURBO ON AM PM QUIET SLEEP ON / OFF 4 5 6 7 12 13 FUNKTION Auswahl der Steuerung für Betriebsmodi (Cool (Kühlen) / Heat (Heizen) / Auto (Auto) / Dry (Trocknen) / Fan (Ventilator)) Aktivierung/Deaktivierung der Turbo-Funktion Pendelsteuerung aktivieren/deaktivieren Taste halten zur Änderung des Swing-Modus Aktivierung/Deaktivierung der Ruhefunktion Eingestellte Temperatur in °C oder °F erhöhen Eingestellte Temperatur in °C oder °F erhöhen Aktivierung/Deaktivierung der Schlaffunktion Einschalten/Ausschalten der OFF TIMER-Einstellungsmodus von Ereignis 1 und 2 Einschalten/Ausschalten der ON TIMER-Einstellungsmodus von Ereignis 1 und 2 Timer aktivieren/deaktivieren Auswahl der Steuerung für Ventilatorgeschwindigkeiten (Auto (Auto)/ High (Hoch)/ Med (Mittel)/ Low (Niedrig)) An/Aus des Geräts mit Löschung aller Timer-Funktionen Einschalten/Ausschalten des Einstellungsmodus der reellen Zeituhr (RTC) HINWEIS: Turbo- und Ruhefunktion sind nur bei ausgewählten Modellen verfügbar. i BEDIENUNGSANLEITUNG 1.1 MODE-Taste (MODUS) Die MODE-Taste betätigen, um den Betrieb von COOL (KÜHL), HEAT* (WARM), AUTO* (AUTO), DRY* (TROCKEN) oder FAN (GEBLÄSE) umzuschalten. Sehen Sie auf dem Display nach, in welchem Modus sich die Steuerung befindet. *HEAT (WARM), AUTO (AUTO) und DRY (TROCKEN) sind nur für ausgewählte Modelle verfügbar. Drücken Sie einmal die TURBO-Taste, um die Turbo-Gebläsedrehzahl zu aktivieren. Das Turbo-Symbol wird angezeigt. Um die Turbo-Gebläsedrehzahl zu deaktivieren und wieder zur vorherigen Gebläsedrehzahl zurückzukehren, drücken Sie erneut einmal die Turbo-Taste. Wenn der Benutzer die FAN-Taste oder die QUIET-Taste drückt oder das Gerät ausschaltet, wird die Turbo-Geschwindigkeit deaktiviert. Diese Geschwindigkeit ist nur bei ausgewählten Modellen im COOL-(Kühl-) und HEAT-(Heiz-)Modus verfügbar. 1.3 Automatische Luftschwingung • Durch Betätigen des SWING Knopfs wird die automatische Luftschwingungsfunktion aktiviert. • Damit die Luft in eine bestimmte Richtung bläst, wird der SWING Knopf betätigt, danach warten, bis sich die Lüftungsschlitze in die gewünschte Richtung bewegen und dann den Knopf nochmals betätigen. Auswahlverfahren für Swing-Modus (von Model abhängig) • Drücken Sie die Taste SWING ( ) für 4 Sekunden lang, um in das Feld des Einstellmodus zu gelangen. Im Feldeinstellungsmodus erscheint nur die Meldung SWING MODE ( ). • Drücken Sie die Temperaturtaste und um die Drehzahl von SWING MODE ( ) von Swing-Modus 1 bis auf Swing-Modus 3 auszuwählen. • Folgende drei automatische Luftschwenkmodi (SWING MODE)stehen zur Verfügung: Luftschwenkmodus 1 Luftschwenkmodus 2 Luftschwenkmodus 3 SWING MODE wird erst aktiviert, wenn SWING eingeschaltet ist. Der Schwenkmodus wird durch dieses Logo angezeigt: • Falls sich keiner Modus innerhalb 4 Sekunden ändert, funktioniert das Gerät gemäß den ausgewählten SWING MODE( ). 1.4 QUIET Ventilatorgeschwindigkeit Drücken Sie einmal die QUIET-Taste, um die Ruhe-Gebläsedrehzahl zu aktivieren. Das QUIET-Symbol wird angezeigt. Um die Ruhe-Gebläsedrehzahl zu deaktivieren und wieder zur vorherigen Gebläsedrehzahl zurückzukehren, drücken Sie erneut einmal die QUIET-Taste. Wenn der Benutzer die FAN-Taste oder die TURBO-Taste drückt oder das Gerät ausschaltet, wird die Ruhe-Geschwindigkeit deaktiviert. Diese Geschwindigkeit ist nur bei ausgewählten Modellen im COOL-(Kühl-) und HEAT-(Heiz-)Modus verfügbar. 1.5 „ “ oder „ “ Temperatur-Einstell-Taste Betätigen Sie die Temperaturtaste und stellen Sie die gewünschte Temperatur ein. Drücken Sie dazu einmal die Taste „ “ oder „ “. Die Temperatur ändert sich um 1 °C oder 1 °F. Der standardmäßig einstellbare Temperaturbereich liegt zwischen 16 °C und 30 °C (60 °F und 86 °F). Wenn die Option 20 - 30 ºC eingestellt ist, wird die Temperaturbereichsgrenze auf 20 ºC bis 30 ºC (68 °F bis 86 °F) eingestellt. Durch gleichzeitiges Drücken beider Knöpfe wird die Temperatureinstellung zwischen Grad Celsius und Grad Fahrenheit umgeschaltet. Im FAN-Modus ist keine Temperatureinstellung zulässig (keine Einstellung der Temperaturanzeige). Es gibt keine Anzeige der Zimmertemperatur. 1.6 SLEEP Funktion Drücken Sie die SLEEP-Taste, um die Schlummerfunktion zu aktivieren. Die SLEEP-Funktion ist im DRYund im FAN-Modus nicht verfügbar. 1.7 DEUTSCH TURBO Ventilatorgeschwindigkeit „ON TIMER“ und „OFF TIMER“ Das Gerät hat 2 Ereignistimer, und zwar Timer 1 und Timer 2. Jedes Ereignis hat jeweils einen ON-TIMER und einen OFF-TIMER. Die Tastendruckfunktionen für Timer ON und Timer OFF werden in Tabelle 1,1 angezeigt. 1 Übersetzung der Original-Anleitungen 1.2 Tabelle 1,1 : Tastendruck- und Ereignissequenz für Timer ON und Timer OFF. TIMER ON KEY (TIMER EIN-TASTE) TIMER OFF KEY (TIMER AUS-TASTE) ON Timer 1 ON Timer 2 OFF Timer 1 OFF Timer 2 Deaktivieren Deaktivieren Deaktivieren Deaktivieren Aktivieren Deaktivieren Aktivieren Deaktivieren Deaktivieren Aktivieren Deaktivieren Aktivieren Aktivieren Aktivieren Aktivieren Aktivieren Alle Timer sind durch Ereignisse ausgelöste Timer und können durch die ON/OFF-Taste und die OverrideFunktion deaktiviert werden. Stellen Sie die Timer für Ereignis 1 und Ereignis 2 ein Der Prozess für Timer ON und Timer OFF ist gleich. 1. Halten Sie die Taste Timer ON/OFF 3 Sekunden lang gedrückt, um in den Timer-Einstellungsmodus zu wechseln. (Das Symbol ON 1 oder OFF 1 blinkt) 2. Drücken Sie UP oder DOWN, um zur Einstellung Timer 1 oder Timer 2 zu wählen. (Wenn „1“ blinkt, bedeutet dies, dass momentan Timer 1 ausgewählt ist. Wenn „2“ blinkt, gibt dies an, dass derzeit Timer 2 ausgewählt ist) 3. Drücken Sie zur Bestätigung erneut die Taste Timer ON/OFF. (Als nächstes blinkt der Tag) 4. Drücken Sie UP oder DOWN, um den Tag auszuwählen. 5. Drücken Sie zur Bestätigung des Tags erneut die Taste Timer ON/OFF. (Als nächstes blinkt die Stunde) 6. Drücken Sie UP oder DOWN, um die Stunde zu ändern. 7. Drücken Sie zur Bestätigung der Stunde erneut die Taste Timer ON/OFF. (Als nächstes blinken die Minuten) 8. Drücken Sie UP oder DOWN, um die Minute zu ändern. 9. Drücken Sie zur Bestätigung der Minute erneut die Taste Timer ON/OFF. Die einzelnen Timer (Timer 1 ON oder Timer 1 OFF oder Timer 2 ON oder Timer 2 OFF) können nur separat nach Durchlaufen sämtlicher 7 Schritte eingestellt werden. Falls während der Timer-Einstellung 5 Sekunden lang keine Tasteneingabe erfolgt, wird der Einstellungsmodus automatisch beendet, und es werden keine Änderungen vorgenommen. Der ON/OFF-Timer wird jeweils nach 1 Minute überprüft. Es wird nicht empfohlen, ON TIMER und OFF TIMER auf die gleichen Werte zu setzen. Sollte dies dennoch auftreten, wird der wirksame Timer mit Priorität behandelt (siehe Tabelle 1,2). Beispiel: ON TMR 2-Einstellungen: DAY (Tag) – TUE (Di), TIMER – 5.00pm (17 Uhr) OFF TMR 1-Einstellungen: DAY (Tag) – TUE (Di), TIMER – 5.00pm (17 Uhr) Ergebnis, wenn die RTC 5.00 pm (17 Uhr) am TUE (Di) erreicht: – wenn das Gerät eingeschaltet ist, keine Reaktion. – wenn das Gerät ausgeschaltet ist, wird es eingeschaltet. Tabelle 1,2 : Timer-Priorität Priorität Timer (Zeiteinstellung) 1 (am höchsten) ONTMR2 2 OFFTMR2 3 ONTMR1 4 (am niedrigsten) OFFTMR1 Bei IR-Empfang löscht die drahtlose IR-Fernbedienung die Einstellungen von ON TIMER 2 und OFF TIMER 2. 2 1.8 DELAY TIMER Funktion Wenn Sie einmal die DELAY TIMER-Taste drücken, wird die Timer-Funktion für 1 Stunde aktiviert. Die Anzeige „OVERRIDE“ wird auf dem LCD eingeblendet. Drücken Sie die Taste erneut und die Einstellung steigt auf 2 Stunden an. Die Anzeige „OVERRIDE“ wird eingeblendet. Ein weiteres Drücken deaktiviert die Timer-Funktion. Nachdem der Timer beendet wurde, werden die Timer-Funktion deaktiviert und das Logo ausgeblendet. Alle anderen Timer werden fortgesetzt. 1.9 FAN Geschwindigkeitsfunktion Die Gebläsedrehzahl kann durch Drücken der FAN-Taste geändert werden: Niedrig > Mittel > Hoch > Automatisch > 1.10 ON/OFF (EIN/AUS) Taste Beginn des Betriebs: – Wenn Sie die ON/OFF-Taste drücken, zeigt das LCD das gesamte Display an und das Gerät wird eingeschaltet. Abschalten des Betriebs: – Wenn Sie die ON/OFF-Taste drücken, zeigt das LCD nur die reelle Zeituhr an und das Gerät wird ausgeschaltet. 1.11 Starteinstellungen Das Gerät wird mit den letzten Einstellungen der Hauptplatine eingeschaltet. Wenn keine Informationen über den letzten Zustand verfügbar sind, verwendet das Gerät die Standardeinstellungen. Die Standardeinstellungen finden Sie nachstehend: Gerät: Modus: Ventilatorgeschwindigkeit: RTC: Luftschwenken (Swing): Luftschwenkmodus: Timer: Turbo: Ruhe (Quiet): Schlummerfunktion (Sleep): Löschen (Override): Aus Kühlen Hohe 12:00AM, MONDAY Aus Standard Ausschalten Ausschalten Aus Aus Ausschalten 1.12 Anzeige der reellen Zeituhr (RTC) Die RTC-Uhr wird während des ON- oder OFF-Zustands des Geräts auf dem Bildschirm angezeigt, außer bei Stromausfällen oder Fehlermeldungen. RTC-Einstellung wählen 1. Drücken Sie einmal die RTC-Taste, um den RTC-Einstellungsmodus zu aktivieren. (Der Tag blinkt.) 2. Drücken Sie UP oder DOWN, um den Tag auszuwählen. 3. Drücken Sie zur Bestätigung des Tags erneut die Taste RTC. (Als nächstes blinkt die Stunde.) 4. Drücken Sie UP oder DOWN, um die Stunde zu ändern. 5. Drücken Sie zur Bestätigung der Stunde erneut die Taste RTC. (Als nächstes blinken die Minuten.) 6. Drücken Sie UP oder DOWN, um die Minute zu ändern. 7. Drücken Sie zur Bestätigung der Minute erneut die Taste RTC. RTC kann nur nach Durchlaufen sämtlicher 7 Schritte eingestellt werden. Falls während der RTC-Einstellung 5 Sekunden lang keine Tasteneingabe erfolgt, wird der Einstellungsmodus automatisch beendet, und es werden keine Änderungen an der Einstellung vorgenommen. 1.13 Tastensperre Die Tastensperrfunktion sperrt alle Änderungen der Einstellungen. Wenn Sie 5 Sekunden lang sowohl die TURBO- als auch die QUIET-Taste gedrückt halten, wird die Tastensperre aktiviert/deaktiviert und „KEYLOCK“ wird auf dem LCD ein-/ausgeblendet. Wenn alle Tasten gesperrt sind, können (zum Entsperren) nur die Tasten ON/OFF, TURBO und QUIET betätigt werden. 3 DEUTSCH *Die FAN-Geschwindigkeit ist im DRY-Modus nicht verfügbar. 1.14 Netzausfallschutz Der Netzausfallschutz wird benötigt, um die RTC und die für 7 Tage programmierbaren Timereinstellungen für jeden neu eingelegten Satz Batterien mindestens für 1 Monat fortwährend beizubehalten, während das Gerät abgeschaltet ist. Für Geräte ohne Netzausfallschutz ist die Standardeinstellung 12:00 a.m. am Montag, und der Timer wird gelöscht, wenn das Gerät wieder angeschaltet wird. 1.15 Fehleranzeige Wird ein anormaler Betriebszustand entdeckt, wird eine Fehlermeldung angezeigt. Die Fehlermeldung wird mithilfe der (blinkenden) RTC-Segmente angezeigt. Das bedeutet, wenn ein Fehler auftritt, wird anstelle der RTC die Fehlermeldung eingeblendet. Das Format für die Fehlermeldung lautet wie folgt: DX-Fehlermeldung Fehlerbeschreibung Raum-Sensor öffnet oder schließt kurz Sensor des Innen-Ventilators öffnet Sensor Außen-Ventilator öffnet Kompressor überlastet/Sensor Innen-Ventilator schließt kurz/Sensor AußenVentilator schließt kurz Niedrige abkühlende Aufladung/Gas strömt aus/Im Freien anormales Wasserpumpe defekt Es gibt einem Sensor für den Außen-Ventilator (MS Modell) Hardware-Fehler (Nadel des Takt-Schalters schließt Kurz) Innenventilator-Rückmeldungsfehler EEPROM-Fehler E1 E2 E3 E4 E5 E6 E7 E8 E9 EE CW-Fehlermeldung Fehlerbeschreibung Raum-Sensor öffnet oder schließt kurz Rohrwasser-Sensor öffnet oder schließt kurz Falsche Rohrwassertemperatur Rohrwasser-Temperatur schlecht oder fehlerhaft Wasserpumpenfehler Hardware-Fehler (Nadel des Takt-Schalters schließt Kurz) Innenventilator-Rückmeldungsfehler E1 E2 E4 E5 E6 E8 E9 Fehlerdiagnose (Nur für inverter) Wird ein abnormaler Zustand entdeckt, so zeigt der Controller SLM9 den jeweiligen Fehlercode mittels Blinken an. FEHLERMELDUNG 00 A1 A3 A5 A6 AH C4 C5 C7 C9 BEDEUTUNG NORMAL LEITERPLATTENFEHLER DER INNENEINHEIT ABLAUFPUMPE ANOMAL FROSTSCHUTZ (KÜHLUNG)/WÄRMEAUSTAUSCHER ÜBERHITZT (HEIZUNG) INNENLÜFTER, MOTOR ANOMAL FEHLER AN ELEKTRO-LUFTREINIGER INNENRAUMWÄRMETAUSCHER (1) THERMISTOR, KURZSCHLUSS/ UNTERBRECHUNG INNENRAUMWÄRMETAUSCHER (2) THERMISTOR, KURZSCHLUSS/ UNTERBRECHUNG FEHLER AN ENDSCHALTER DER LUFTKLAPPE INNENRAUMTHERMISTOR, KURZSCHLUSS/UNTERBRECHUNG 4 J7 J8 J9 L1 L3 L4 L5 L8 L9 LC P1 P4 PJ U0 U2 U4 U7 UA UF UH BEDEUTUNG AUSSEN-PBC-FEHLER HOCHDRUCKSCHUTZ NIEDERDRUCKSCHUTZ KOMPRESSORMOTOR VERRIEGELT/KOMPRESSOR ÜBERLASTET KOMPRESSOR-ANLAUFFEHLER DC-AUSSENVENTILATORMOTOR VERRIEGELT AC-EINGANGSSTROM ZU HOCH EXV FEHLER VIERWEGVENTILFEHLER AUSLASSROHR ÜBERHITZT WÄRMEAUSTAUSCHER ÜBERHITZT KOMPRESSORENSENSOR-SYSTEMFEHLER FEHLER AN HOCHDRUCKSCHALTER KOMPRESSOR-FEEDBACK-ERFASSUNGSFEHLER VENTILATORMOTOR ÜBERLASTET/ÜBERSPANNUNG/SENSORFEHLER AC-STROM-SENSORFEHLER AUSSENLUFT-THERMISTOR KURZ/OFFEN FEHLER AN DRUCKFÜHLER KOMPRESSORABLUFTROHR-THERMISTOR KURZ/OFFEN/VERLEGT KURZSCHLUSS/UNTERBRECHUNG AN ANSAUGTHERMISTOR AUSSENTÜRWÄRMEAUSTAUSCHER KURZ/OFFEN KURZSCHLUSS/UNTERBRECHUNG AN UNTERKÜHLUNGSTHERMISTOR DES WÄRMETAUSCHERS FLÜSSIGKEITSLEITUNGSROHR-THERMISTOR KURZ/OFFEN GASLEITUNGSROHR-THERMISTOR KURZ/OFFEN FEHLER AN LEITERPLATTE DES INVERTERS STEUERKASTEN AUSSEN ÜBERHITZT KÜHLKÖRPER ÜBERHEIZT IPM FEHLER/IGBT FEHLER ÜBERSPANNUNG AN INVERTERKOMPRESSOR ÜBERSPANNUNGSSCHUTZ AM KOMPRESSOR ÜBERTRAGUNGSFEHLER (LEITERPLATTE AN AUSSENSTEUERUNG UND INVERTER) OFFENE PHASE ODER SPANNUNGSUNTERSCHIEDE KÜHLKÖRPER-THERMISTOR KURZ/OFFEN FEHLER BEI LEISTUNGSEINSTELLUNG GAS UNGENÜGEND DC-SPANNUNG NICHT IM NORMALBEREICH KOMMUNIKATION, FEHLER KOMMUNIKATIONSFEHLER (STEUER-PCB UND IPM-PCB AUSSEN) INSTALLATIONSFEHLER FEHLERHAFTE VERROHRUNG & VERDRAHTUNG/FALSCH VERKABELT/ZU WENIG GAS FROSTSCHUTZ (ANDERE RÄUME) 5 DEUTSCH FEHLERMELDUNG E1 E3 E4 E5 E6 E7 E8 E9 EA F3 F6 HO H3 H6 H7 H8 H9 J1 J3 J5 J6 2.0 HARDWARE-EINSTELLUNG Das Gerät verfügt über 2 Überbrückungsschalter-Optionen zur Steuerung der Schalttafelfunktion. Tabelle 2,0 : Zusammenfassung der Hardware-Einstellungen OPTION Mit Überbrückungsschalter Ohne Überbrückungsschalter Temp.-Bereich einstellen Temp.-Bereich von 20°C – 30°C einstellen Temp.-Bereich von 16°C – 30°C einstellen (Standard) TURBO_QUIET Turbo- und Ruhe-Gebläsedrehzahl deaktivieren (Standard) Turbo- und Ruhe-Gebläsedrehzahl aktivieren * Trifft nur auf Modelle mit integrierten Turbo- oder Ruhefunktionen zu. 3.0 INSTALLATION 3.1 Zubehör Folgendes Zubehör wird zusammen mit diesem Handbuch mitgeliefert. Sollte etwas fehlen, wenden Sie sich bitte sogleich an Ihren Fachhändler. 1. Fernbedienung 2. Holzschrauben (2 Stück) & Maschinenschrauben (2 Stück) 3. Gebrauchsanweisung 4. Batterie 3.2 Installierungsschritte I. Öffnen Sie zuerst den Clip an der Oberseite des Controllers, gefolgt vom Clip an der Unterseite. Entfernen Sie das Gehäuseoberteil des Controllers vom Unterteil des Gehäuses. II. Befestigen Sie das Unterteil des Gehäuses mit den beiden mitgelieferten Schrauben an der Wand. Führen Sie danach die Verbindungsdrähte durch den Schlitz oben in der Mitte des Gehäuses, wie unten gezeigt, ein. III. Führen Sie dann zuerst wieder den unteren Clip ein, und rasten Sie anschließend das obere Teil ein. Verbindungsdrähte LCD Fern (Obere Abdeckung) MOD E TURB O SWIN G DELA Y TIMER QUIE T TIMER TIMER FAN SLEE P ON / OFF 2 x Holzschrauben 6 LCD Fern (Gehäuseunterteil) MITTEILUNG BRC51A61/62 Indicazione Del Regolatore AUTO ON 12 OFF 12 MON TUE WED THU FRI SAT SUN ALL OVERRIDE 12 DRY COOL TURBO QUIET 3 2 1 MODE 10 9 11 8 NO AUTO DELAY TIMER HEAT FAN SWING SLEEP F C SET TEMP. TURBO SWING TIMER TIMER ON AM PM OFF 4 5 QUIET SLEEP FAN ON / OFF TASTO 6 7 12 13 FUNZIONE 1. MODE Seleziona controllo modalità operative (Cool (Fresco) / Heat (Riscaldamento) / Auto (Automatico) / Dry (Secco) / Fan (Ventola)) 2. TURBO Attiva/disattiva la funzione Turbo 3. SWING Attiva/disattiva il controllo dell'oscillazione Tenere premuto il tasto per cambiare modalità oscillazione 4. QUIET Attiva/disattiva Funzione silenziosa 5. SET TEMP UP Aumenta la temperatura impostata in °C o °F 6. SET TEMP DOWN Diminuisce la temperatura impostata in °C o °F 7. SLEEP Attiva/disattiva la funzione di “riposo” 8. OFF TIMER Attiva/disattiva la modalità di impostazione Event 1 and 2 OFF TIMER (TIMER DISATTIVO evento 1 e 2) 9. ON TIMER Attiva/disattiva la modalità di impostazione Event 1 and 2 ON TIMER (TIMER ATTIVO evento 1 e 2) 10. DELAY TIMER Attiva/disattiva il timer di ritardo 11. FAN Seleziona il controllo della velocità del ventilatore (Auto (Automatica)/ High (Alta)/ Med (Media)/ Low (Bassa)) 12. ON/OFF Accende/spegne l'unità annullando tutte le impostazioni del timer 13. REAL TIME CLOCK (RTC) Abilita/disabilita la modalità di impostazione Real Time Clock (RTC) (Orologio in tempo reale) NOTA: Le funzioni Turbo e Quiet sono solo per il modelli selezionati. i ISTRUZIONI PER L’USO 1.1 Tasto MODE Premere il tasto MODE per passare tra COOL (FRESCO), HEAT* (RISCALDAMENTO), AUTO* (AUTOMATICO), DRY* (SECCO), FAN (VENTOLA). Controllare il display per vedere in quale modalità è impostato il controllo. *HEAT (RISCALDAMENTO), AUTO (AUTOMATICO) e DRY (SECCO) sono disponibili solo per i modelli selezionati. 1.2 Velocità della Ventola TURBO Premere una volta il tasto TURBO per attivare Velocità della Ventola Turbo. Viene visualizzato il simbolo Turbo. Per disabilitare la Velocità della Ventola Turbo e tornare alla velocità precedente della ventola, premere di nuovo il tasto Turbo. Se l'utente preme il tasto FAN (VENTOLA) o QUIET o spegne l'unità, la velocità Turbo viene disabilitata. Questa velocità è valida solo durante le modalità COOL (FRESCO) e HEAT (RISCALDAMENTO) per i modelli selezionati. • Premere il tasto SWING per attivare l’oscillazione dell’aria. • Per distribuire il flusso d’aria in una direzione specifica, premere il tasto SWING ed aspettare fino a che le alette dei ventilazione si posizionano nella direzione desi-erata quindi premere nuovamente il tasto. Metodo di scelta della modalità di oscillazione (a seconda del modello) • Premere il pulsante SWING ( ) per 4 secondi per entrare nella modalità impostazione campo. In modalità impostazione locale, si visualizza solo la SWING MODE ( ) (MODALITÀ SWING). • Premere il pulsante temperatura e per selezionare il passaggo della SWING MODE ( ) (MODALITÀ SWING) da modalità oscillazione 1 a modalità oscillazione 3. • Ci sono 3 diverse MODALITÀ SWING che sono: Modalità swing 1 Modalità swing 2 Modalità swing 3 La SWING MODE (MODALITÀ SWING) non si attiva se non è attivato SWING. Swing è indicato dal logo: • Se non c’è nessun cambio di modalità entro 4 secondi, l’unità funzione secondo la SWING MODE ( (MODALITÀ SWING) selezionata. 1.4 ) Velocità della Ventola QUIET Premere una volta il tasto QUIET per attivare Velocità della Ventola silenziosa. Viene visualizzato il simbolo QUIET. Per disabilitare la Velocità della Ventola silenziosa e tornare alla velocità precedente della ventola, premere di nuovo il tasto QUIET. Se l'utente preme il tasto FAN (VENTOLA) o TURBO o spegne l'unità, la velocità silenziosa viene disabilitata. Questa velocità è valida solo durante le modalità COOL (FRESCO) e HEAT (RISCALDAMENTO) per i modelli selezionati. 1.5 Tasto “ ” o “ ” Imposta temperatura Premere il tasto di temperatura e impostare la temperatura desiderata premendo una volta il tasto “ ” o “ ”. La temperatura cambia di 1°C o 1°F. I valori di temperatura predefiniti sono compresi tra i 16°C ed i 30°C (60°F ed 86°F). Quando si imposta l'Opzione 20 - 30ºC, il limite del valore di temperatura è impostato tra i 20ºC e i 30ºC (68°F ed 86°F). Premendo contemporaneamente entrambi i tasti i valori di temperatura cambiano tra ºC e ºF. Nessun valore di temperatura è consentito durante la modalità FAN (VENTOLA) (nessuna visualizzazione di impostazione temperatura). Non vi è alcuna visualizzazione della temperatura ambiente. 1.6 Funzione SLEEP Premere il tasto SLEEP per attivare la funzione di “riposo”. La funzione SLEEP non è disponibile nelle modalità DRY (SECCO) e FAN (VENTOLA). 1.7 “ON TIMER” e “OFF TIMER” L’unità dispone di 2 timer di evento, Timer 1 e Timer 2; ciascun evento dispone di un ON TIMER e un OFF TIMER. L'attività di pressione del tasto per Timer ON e Timer OFF viene illustrata nella Tabella 1,1. 1 ITALIANO Deviatore di flusso orientabile automatico Traduzione delle istruzioni originali 1.3 Tabella 1,1: Pressione del tasto Timer ON e Timer OFF e sequenza eventi. TASTO TIMER ON ON Timer 1 ON Timer 2 Disattivato TASTO TIMER OFF OFF Timer 1 OFF Timer 2 Disattivato Disattivato Disattivato Attivato Disattivato Attivato Disattivato Disattivato Attivato Disattivato Attivato Attivato Attivato Attivato Attivato Tutti i timer sono attivati da evento e possono essere annullati dal tasto ON/OFF e dalla funzione Override. Imposta timer Evento 1 ed Evento 2 La procedura di Timer ON e Timer OFF è uguale. 1. Tenere premuto il tasto Timer ON/OFF per 3 secondi per accedere alla modalità di impostazione del timer. (L'icona ON 1 o OFF 1 lampeggia) 2. Premere UP o DOWN per impostare Timer 1 o Timer 2. (Il lampeggio di ‘1’ indica che attualmente è selezionato Timer 1, il lampeggio di ‘2’ indica che attualmente è selezionato Timer 2) 3. Premere di nuovo il tasto Timer ON/OFF per confermare. (Il giorno lampeggia successivamente) 4. Premere UP o DOWN per selezionare il giorno. 5. Premere di nuovo il tasto Timer ON/OFF per confermare il giorno. (L'ora lampeggia successivamente) 6. Premere UP o DOWN per cambiare l'ora. 7. Premere di nuovo il tasto Timer ON/OFF per confermare l'ora. (Il minuto lampeggia successivamente) 8. Premere UP o DOWN per cambiare il minuto. 9. Premere di nuovo il tasto Timer ON/OFF per confermare il minuto. Ogni timer (Timer 1 ON o Timer 1 OFF oppure Timer 2 ON o Timer 2 OFF) vengono impostati separatamente solo una volta eseguiti tutti i 7 passi. Se non vi è alcuna pressione dei tasti per 5 secondi durante l'impostazione del timer, si esce automaticamente dalla modalità di impostazione e non viene eseguita alcuna modifica. ON/OFF Timer viene controllato ogni minuto. Si consiglia di non impostare gli stessi valori per ON TIMER e OFF TIMER. In caso contrario, il timer effettivo avrà priorità come indicato nella Tabella 1,2. Esempio: Impostazioni di ON TMR 2: DAY – TUE, TIMER – 5.00pm Impostazioni di OFF TMR 1: DAY – TUE, TIMER – 5.00pm Risultato quando RTC raggiunge 5.00pm TUE: – con l'unità accesa, nessuna risposta. – con l'unità spenta, tale unità si accende. Tabella 1,2: Priorità timer Priorità Timer 1 (Massima) ONTMR2 2 OFFTMR2 3 ONTMR1 4 (Minima) OFFTMR1 Alla ricezione IR, il telecomando wireless IR annulla le impostazioni ON TIMER 2 e OFF TIMER 2. 2 1.8 Funzione DELAY TIMER Premere una volta il tasto DELAY TIMER per attivare la funzione del timer di ritardo per 1 ora. Sul display LCD viene visualizzato l'indicatore “OVERRIDE”. Premere di nuovo lo stesso tasto per aumentare l'impostazione su 2 ore. Viene visualizzato l'indicatore “OVERRIDE”. La pressione successiva disattiva la funzione del timer di ritardo. Al completamento del timer di ritardo, la funzione del timer di ritardo viene disattivata e il logo è OFF. Tutti gli altri timer vengono ripristinati. 1.9 Funzione velocità FAN È possibile modificare la velocità della ventola premendo il tasto FAN: Bassa > Media > Alta > Automatica > *La velocità FAN non è disponibile in modalità DRY. 1.10 Tasto ON/OFF Operazione di avvio: – Premendo il tasto ON/OFF, il display LCD appare a schermo intero e l'unità si accende. 1.11 Impostazioni di accensione L'unità si avvia con l'impostazione dell'ultimo stato della scheda principale durante l'accensione. Se le informazioni sull'ultimo stato non sono disponibili, l'unità utilizza le impostazioni predefinite. Le impostazioni predefinite sono le seguenti: Unità: Modalità: Velocità della Ventola: RTC: Oscillazione: Modalità di oscillazione: Timer: Turbo: Quiet: Sospensione: Annullamento: Fuori Di Raffreddamento Alto 12:00AM, MONDAY Fuori Di Standard Disabilita Disabilita Fuori Di Fuori Di Disabilita 1.12 Visualizzazione di Real-time Clock (RTC) RTC viene visualizzato sullo schermo durante l'accensione (ON) o lo spegnimento (OFF) dell'unità, tranne in caso di errore di alimentazione o codice di errore. Esegui impostazione RTC 1. Premendo una volta il tasto RTC si attiva la modalità di impostazione RTC. (Il giorno lampeggia) 2. Premere UP o DOWN per selezionare il giorno. 3. Premere di nuovo RTC per confermare il giorno. (L'ora lampeggia successivamente) 4. Premere UP o DOWN per cambiare l'ora. 5. Premere di nuovo RTC per confermare l'ora. (Il minuto lampeggia successivamente) 6. Premere UP o DOWN per cambiare il minuto. 7. Premere di nuovo RTC per confermare il minuto. RTC viene impostato solo una volta eseguiti tutti i 7 passi. Se non vi è alcuna pressione dei tasti per 5 secondi durante l'impostazione di RTC, si esce automaticamente dalla modalità di impostazione e non viene eseguita alcuna modifica all'impostazione. 1.13 Blocco tasti Questa funzione di blocco tasti impedisce qualsiasi modifica all'impostazione. Tenendo premuti i tasti TURBO e QUIET per 5 secondi, si attiva/disattiva la funzione di blocco tasti; sul display LCD appare/scompare “KEYLOCK”. Una volta bloccati tutti i tasti, è possibile premere solo ON/OFF, TURBO e QUIET (per sbloccare). 3 ITALIANO Operazione di arresto: – Premendo il tasto ON/OFF, il display LCD mostra solo l'orologio in tempo reale e l'unità si spegne. 1.14 Batteria di riserva La batteria di riserva viene utilizzata per memorizzare le impostazioni di RTC e del timer programmabile per 7 giorni durante lo spegnimento continuo per un minimo di 1 mese per ogni nuovo set di batteria installato. Per unità senza batteria di riserva, l'impostazione predefinita sarà 12:00am di martedì e la cancellazione del timer all'accensione. 1.15 Indicatore errore In caso di condizioni di anomalia, viene visualizzato un codice di errore. Il codice di errore viene visualizzato utilizzando segmento RTC (lampeggio), ovvero ogni volta che si verifica un errore, RTC non viene visualizzato, ma appare il codice di errore. Il formato del codice di errore è il seguente: Codice errore DX Descrizione errori Sensore ambiente interrotto o in corto Sensore serpentina interna interrotto Sensore serpentina esterna interrotto Sovraccarico del compressore/Sensore serpentina interna in corto/Sensore serpentina esterna in corto Carica di refrigerante a basso/Perdita di gas/All’aperto anormale Guasto alla pompa dell’acqua Sensore serpentina esterna esistente (modello MS) Errore hardware (Piedino interruttore a sfioramento in corto) Errore ritorno ventola interna Errore EEPROM E1 E2 E3 E4 E5 E6 E7 E8 E9 EE Codice errore CW Descrizione errori Sensore ambiente interrotto o in corto Sensore dell’Acqua dei Tubi interrotto o in corto Temperatura dell’Acqua dei Tubi inadeguata Errore/guasto della Temperatura dell’Acqua dei Tubi Errore Pompa Acqua Errore hardware (Piedino interruttore a sfioramento in corto) Errore ritorno ventola interna E1 E2 E4 E5 E6 E8 E9 Segnalazione Errore (Solo per inverter) Se viene rilevata un’anomalia, il codice di errore lampeggerà sul telecomando a fili SLM 9. CODICE ERRORE SIGNIFICATO 00 NORMALE A1 ERRORE SCHEDA ELETTRONICA UNITÀ INTERNA A3 ANOMALIA POMPA DI SCARICO A5 SCAMBIATORE ANTIGELO (RAFFREDDAMENTO)/CALORE (RISCALDAMENTO) A6 ANOMALIA MOTORE VENTILATORE UNITÀ INTERNA AH ANOMALIA ELETTRICA FILTRO DELL’ARIA C4 TERMISTORE SCAMBIATORE DI CALORE (1) UNITÀ INTERNA IN CORTO/APERTO C5 TERMISTORE SCAMBIATORE DI CALORE (2) UNITÀ INTERNA IN CORTO/APERTO C7 ERRORE INTERRUTTORE DI FINE CORSA FERITOIA DÌ VENTILAZIONE C9 TERMISTORE UNITÀ INTERNA IN CORTO/APERTO 4 J3 J5 J6 J7 J8 J9 L1 L3 L4 L5 L8 L9 LC P1 P4 PJ U0 U2 U4 U7 UA UF UH SIGNIFICATO ERRORE DEL PCB ESTERNO PROTEZIONE DA ALTA PRESSIONE PROTEZIONE BASSA PRESSIONE BLOCCO DEL MOTORE COMPRESSORE/COMPRESSORE SOVRACCARICO ERRORE DI AVVIAMENTO DEL COMPRESSORE BLOCCO MOTORE VENTOLA CC ESTERNO SOVRACORRENTE ENTRATA CA ERRORE EXV ERRORE DELLA VALVOLA A 4 VIE SURRISCALDAMENTO DEL TUBO DI SCARICO SURRISCALDAMENTO DELLO SCAMBIATORE DI CALORE ERRORE DEL SISTEMA DEL SENSORE DEL COMPRESSORE ERRORE INTERRUTTORE ALTA PRESSIONE ERRORE DI RILEVAMENTO DEL FEEDBACK DEL COMPRESSORE MOTORE VENTOLA SOVRACCARICATO/SOVRACORRENTE/ANOMALIA SENSORE ERRORE DEL SENSORE DI CORRENTE CA TERMISTORE ARIA ESTERNA IN CORTO/APERTO ERRORE SENSORE DI PRESSIONE TERMISTORE TUBO DI MANDATA COMPRESSORE IN CORTO/APERTO/MAL POSIZIONATO TERMISTORE TUBO DI MANDATA IN CORTO/APERTO TERMISTORE SCAMBIATORE DI CALORE UNITÀ ESTERNA IN CORTO/APERTO TERMISTORE SCAMBIATORE DI CALORE SUBRAFFREDDAMENTO IN CORTO/ APERTO TERMISTORE TUBO LIQUIDI IN CORTO/APERTO TERMISTORE TUBO DEL GAS IN CORTO/APERTO ERRORE PCB ESTERNA INVERTER SURRISCALDAMENTO SCATOLA DI CONTROLLO ESTERNA SURRISCALDAMENTO DISSIPATORE DI CALORE ERRORE IPM/ERRORE IGBT SOVRACORRENTE COMPRESSORE INVERTER PREVENZIONE SOVRACORRENTE COMPRESSORE ERRORE DI COMUNICAZIONE (PCB ESTERNA DI CONTROLLO E PCB INVERTER) FASE APERTA O SQUILIBRIO DI TENSIONE TERMISTORE DISSIPATORE DI CALORE IN CORTO/APERTO ERRORE IMPOSTAZIONE CAPACITÀ GAS INSUFFICIENTE TENSIONE CC FUORI RANGE ERRORE DI COMUNICAZIONE ERRORE DI COMUNICAZIONE (PCB ESTERNA DI CONTROLLO E PCB IPM) ERRORE INSTALLAZIONE MANCATA CORRISPONDENZA INSTALLAZIONE TUBI E CAVI/CABLAGGIO ERRATO/ GAS INSUFFICIENTE ANTICONGELAMENTO (ALTRI AMBIENTI) 5 ITALIANO CODICE ERRORE E1 E3 E4 E5 E6 E7 E8 E9 EA F3 F6 HO H3 H6 H7 H8 H9 J1 2.0 CONFIGURAZIONE HARDWARE L'unità dispone di 2 ponticelli per controllare la funzione della scheda. Tabella 2,0: Riepilogo delle impostazioni hardware OPZIONE Con ponticello Senza ponticello Imposta valore temp. Imposta valore temp. tra 20°C e 30°C Imposta valore temp. tra 16°C e 30°C (Predefinito) TURBO_QUIET Disabilita velocità ventola Turbo e silenziosa (Predefinito) Abilita velocità ventola Turbo e silenziosa * Applicabile solo su modelli con funzioni Turbo o Quiet integrate. 3.0 INSTALLAZIONE 3.1 Accessori I seguenti accessori sono inclusi con il presente manuale. Nel caso dovesse mancare qualche componente, contattare immediatamente il rivenditore. 1. Telecomando 2. Viti in legno (2 viti) & Viti senza dado (2 viti) 3. Manuale di installazione 4. Batteria 3.2 Guida dettagliata I. Aprire prima il fermo sopra il controller, quindi il fermo inferiore. Rimuovere la scatola superiore del controller dalla scatola inferiore. II. Fissare la scatola inferiore a parete con le 2 viti in dotazione. Quindi inserire il cavo di connessione attraverso la fessura nella scatola centrale superiore come illustrato. III. Inserire prima il fermo inferiore, quindi il fermo superiore. Cavi di connessione LCD Remoto (scatola superiore) MOD E TURB O SWIN G DELA Y TIMER QUIE T TIMER TIMER FAN SLEE P ON / OFF 2 x viti in legno 6 LCD Remoto (Scatola inferiore) PROMEMORIA BRC51A61/62 Indicación Del Regulador AUTO ON 12 OFF 12 MON TUE WED THU FRI SAT SUN ALL OVERRIDE 12 DRY COOL TURBO QUIET 3 2 1 MODE 10 9 11 8 NO AUTO DELAY TIMER HEAT FAN SWING SLEEP F C SET TEMP. TURBO SWING TIMER TIMER ON AM PM OFF FAN 4 5 QUIET SLEEP ON / OFF TECLA 6 7 12 13 FUNCIÓN 1. MODE Selecciona el control de Modos de funcionamiento (Cool (Frio) / Heat (Calor) / Auto / Dry (seco) /Fan (ventilacion)) 2. TURBO Activa/desactiva la función Turbo 3. SWING Activa/desactiva el control de inclinación Sostenga la tecla para cambiar el Modo swing 4. QUIET Activa/desactiva la función Silencio 5. SET TEMP UP Aumenta la temperatura seleccionada en °C o °F 6. SET TEMP DOWN Reduce la temperatura seleccionada en °C o °F 7. SLEEP Activa/desactiva la función de apagado automático 8. OFF TIMER Activa/desactiva el modo de ajuste de Event 1 y 2 de OFF TIMER 9. ON TIMER Activa/desactiva el modo de ajuste de Event 1 y 2 de ON TIMER 10. DELAY TIMER Activa/desactiva temporizador de retardo 11. FAN Selección el control de velocidad del ventilador (Auto / High (Alto) / Med (Medio) / Low (Bajo)) 12. ON/OFF Enciende/apaga la unida cancelando todos los ajustes del temporizador 13. RELOJ DE TIEMPO REAL (RTC) Activa/desactiva el modo de selección de Reloj de tiempo real (RTC) NOTA: La función Turbo y Silencio son solo para los modelos seleccionados. i INSTRUCCIONES DE OPERACIÓN 1.1 Botón MODE Pulse el botón MODE para cambiar la operación de COOL (FRIO), HEAT* (CALOR), AUTO*, DRY* (SECO), FAN (VENTILACIÓN). Compruebe el indicador para ver en que modo el control está ajustado. *HEAT (CALOR), AUTO y DRY (SECO) están disponibles solo para los modelos seleccionados. 1.2 Velocidad de ventilador TURBO Pulse la tecla TURBO una vez para activar la velocidad de ventilación Turbo. Se mostrará un símbolo Turbo. Para deshabilitar la velocidad de ventilación Turbo y volver a la anterior velocidad de ventilación, pulse de nuevo la tecla Turbo. Si el usuario presiona el botón FAN (VENTILACIÓN) o el botón QUIET o apaga la unidad, la velocidad turbo se deshabilitará. Esta velocidad es solo válida durante el modo COOL (FRIO) y HEAT (CALOR) para los modelos seleccionados. 1.3 Oscilación de aire automática • Presione el botón SWING para activar la función de oscilación automática de aire. • Para distribuir el aire en una dirección específica, presione el botón SWING y espere hasta que la paleta se mueva a la dirección deseada y presione de nuevo el botón. Modo swing 1 Modo swing 2 Modo swing 3 El MODO SWING no se activará a menos que SWING esté activado. SWING está indicado por el logo: • Si no se cambia el modo durante 4 segundos, el aparato funcionará de acuerdo con el MODOS SWING ( ) seleccionado. 1.4 Velocidad de ventilación QUIET Pulse la tecla QUIET una vez para activar la velocidad de ventilación Quiet. Se mostrará un símbolo QUIET. Para deshabilitar la velocidad de ventilación Quiet y volver a la anterior velocidad de ventilación, pulse de nuevo la tecla QUIET. Si el usuario presiona el botón FAN o el botón TURBO o apaga la unidad, la velocidad quiet se deshabilitará. Esta velocidad es solo válida durante el modo COOL (FRIO) y HEAT (CALOR) para los modelos seleccionados. 1.5 Botón de Ajuste de la Temperatura “ ” o “ ” Presione el botón temperatura y ajuste la temperatura de su elección presionando el botón “ ” o “ ” una vez, la temperatura cambia 1ºC o 1ºF. El alcance del ajuste por defecto está entre 16ºC a 30ºC (60ºF a 80ºF). Cuando se ajusta la opción 20 - 30ºC, el límite de alcance se establece de 20ºC a 30ºC (68°F a 86°F). Presionar ambas teclas simultáneamente cambiará el ajuste de temperatura entre ºC y ºF. No se permite ningún ajuste de temperatura durante el modo FAN (No se muestra ajuste de temperatura). No hay muestra de temperatura de la habitación. 1.6 Función SLEEP Presione el botón SLEEP para activar el modo sleep. La función SLEEP no está disponible en modos DRY (SECO) y FAN (VENTILACIÓN). 1.7 “ON TIMER” y “OFF TIMER” La unidad tiene 2 temporizadores de evento, es decir Temporizador 1 y Temporizador 2, cada evento tiene un ON TIMER y un OFF TIMER. La actividad de presión de tecla para Timer ON y Timer OFF se muestra en la Tabla 1,1 1 Traducción de las instrucciones originales • Pulse el botón SWING ( ) durante 4 segundos para entrar en el modo de configuración de campo. Durante el modo de configuración de campo, sólo mostrará el MODO SWING ( ). • Pulse el botón y para seleccionar la rotación del MODOS SWING ( ) desde el Modo de Oscilación 1 al Modo de Oscilación 3. • Hay 3 MODOS SWING diferentes, que son: ESPAÑOL Método de selección del modo de oscilación (depende del modelo) Tabla 1,1 : Presión de tecla Timer ON y Timer OFF y secuencia de evento. TECLA TIMER ON TECLA TIMER OFF ON Temporizador 1 ON Temporizador 2 OFF Temporizador 1 OFF Temporizador 2 Desactivado Desactivado Desactivado Desactivado Activado Desactivado Activado Desactivado Desactivado Activado Desactivado Activado Activado Activado Activado Activado Todos los temporizadores disparan los sucesos y pueden anularse con el botón ON/OFF y la función de cancelación. Ajuste de los temporizadores Event 1 y Event 2 El proceso para Temporizador ON y Temporizador OFF es el mismo. 1. Presione y sostenga la tecla Temporizador ON/OFF durante 3 segundos para ir al modo de ajuste del reloj. (El Icono ON 1 o OFF 1 parpadeará) 2. Pulse UP o DOWN para seleccionar Temporizador 1 o Temporizador 2 a ajustar. (‘1’ parpadeo indica que Temporizador 1 está seleccionado actualmente, ‘2’ parpadeo indica que Temporizador 2 está seleccionado actualmente) 3. Pulse la tecla Temporizador ON/OFF de nuevo para confirmar. (A continuación parpadeará Día) 4. Pulse UP o DOWN para seleccionar el día. 5. Pulse la tecla Temporizador ON/OFF de nuevo para confirmar el día. (A continuación parpadeará Hora) 6. Pulse UP o DOWN para cambiar la hora. 7. Pulse la tecla Temporizador ON/OFF de nuevo para confirmar la hora. (A continuación parpadearán los minutos) 8. Pulse UP o DOWN para cambiar los minutos. 9. Pulse la tecla Temporizador ON/OFF de nuevo para confirmar los minutos. Cada temporizador (Temporizador 1 ON o Temporizador 1 OFF o Temporizador 2 ON o Temporizador 2 OFF) solo se ajustará por separado después de 7 pasos, si no se utiliza la tecla durante 5 segundos durante el ajuste del temporizador, sale automáticamente el modo de ajuste y no se hará ningún cambio. Se verificará el temporizador ON/OFF cada 1 minuto. No es recomendable ajustar el ON TIMER y OFF TIMER para tener los mismos valores. Si ocurre esto, el temporizador efectivo se tratará con prioridad como se indica en la Tabla 1,2. Ejemplo: ON TMR 2 ajustes: DÍA – TUE (MAR), TIMER (TEMPORIZADOR) – 5.00pm OFF TMR 1 ajustes: DÍA – TUE (MAR), TIMER (TEMPORIZADOR) – 5.00pm Resultado cuando RTC alcanza 5.00pm el MAR: – cuando la unidad está conectada, no hay respuesta. – cuando la unidad está desconectada, la unidad se disparará a conectado. Tabla 1,2 : Prioridad de temporizador Prioridad Temporizador 1 (La más alta) ONTMR2 2 OFFTMR2 3 ONTMR1 4 (La más baja) OFFTMR1 Sobre la recepción IR, el mando a distancia inalámbrico IR anulará los ajustes de ON TIMER 2 y OFF TIMER 2. 2 1.8 Función DELAY TIMER Presione la tecla DELAY TIMER una vez y se activará la función de temporizador de retardo durante 1 hora. Se mostrará un indicador “OVERRIDE” en el LCD. Pulse la misma tecla de nuevo y la selección aumentará a 2 horas. Se mostrará un indicador “OVERRIDE” . Si vuelve a pulsar se desactivará la función de temporizador de retardo. Después de que se complete el temporizador de retardo, la función de temporizador de retardo se desactiva y el logo está en OFF. Se reanudarán el resto de temporizadores. 1.9 Función FAN Speed Se puede cambiar la velocidad del ventilador presionando la tecla FAN: Bajo > Medio > Alto > Auto > *La velocidad del FAN no está disponible en modo DRY. 1.10 Botón ON/OFF Operación de puesta en marcha: – Presione el botón ON/OFF, el LCD mostrará la pantalla completa y la unidad se encenderá. Operación de parada: – Presione el botón ON/OFF, el LCD mostrará el reloj de tiempo real y la unidad se apagará. 1.11 Ajustes de encendido Unidad: Modo: Velocidad de ventilador: RTC: Oscilación: Modo swing: Temporizadores: Turbo: Silencio: Dormir: Anulación: Apagado Frío Alta 12:00AM, MONDAY Apagado Estándar Deshabilitar Deshabilitar Apagado Apagado Deshabilitar 1.12 Pantalla de Reloj de tiempo real (RTC) Se muestra RTC en la pantalla durante la unidad ON u OFF excepto para fallo de energía o código de error. Establecer ajuste RTC 1. Presione la tecla RTC una vez para activar el modo de selección de RTC. (Parpadeará el Día) 2. Pulse UP o DOWN para seleccionar el día. 3. Presione RTC de nuevo para confirmar el día. (A continuación parpadeará Hora) 4. Pulse UP o DOWN para cambiar la hora. 5. Presione RTC de nuevo para confirmar la hora. (A continuación parpadearán los minutos) 6. Pulse UP o DOWN para cambiar los minutos. 7. Presione RTC de nuevo para confirmar los minutos. El RTC solo estará ajustado después de 7 pasos, si no se no se utiliza ninguna tecla durante 5 segundos durante el ajuste RTC, saldrá automáticamente del modo de ajuste, y no se realizará ningún cambio al ajuste. 1.13 Bloqueo de teclas Esta función de bloqueo evita cualquier cambio en los ajustes. Presionar y sostener las teclas TURBO y QUIET durante 5 segundos activará/desactivará la función de bloqueo de tecla; aparecerá/desaparecerá “KEYLOCK” en el LCD. Una vez bloqueadas las teclas, sólo se podrán pulsar las teclas ON/OFF, TURBO y QUITE (para desbloquear). 3 ESPAÑOL La unidad se encenderá con el ajuste del último estado del cuadro principal durante el encendido. Si la información del último estado no está disponible, la unidad utilizará los ajustes por defecto. Los ajustes por defecto son como se indica abajo: 1.14 Reserva de batería La reserva de batería se utiliza para retener los valores del RTC y los ajustes del temporizador programable de siete días durante cortes de alimentación eléctrica durante un mínimo de 1 mes seguido para cada nuevo conjunto de pilas instaladas. Para las unidades sin reserva de batería, los ajustes por defecto serán 12:00 am el lunes y se borrará el temporizador durante el encendido. 1.15 Indicador de error Si se detecta cualquier condición anormal, se mostrará un código de error. El código de error se muestra utilizando segmentos de RTC (parpadeando), lo que quiere decir que cada vez que haya un error, no se mostrará RTC en lugar del código de error. El formato para el código de error será el siguiente: Código de error DX Descripción de error El sensor de habitación abierto o corto Sensor de bobina de interior abierto Sensor de bobina de interior abierto Sobrecarga de compresor/Sensor de bobina de interior corto/Sensor de bobina de exterior corto Baja carga de refrigerante/Escape de gas/Exterior anormal Falla de bomba de agua Aparece el sensor de bobina exterior (Modelo MS) Error de hardware (interruptor de clavija de tacto corto) Error de respuesta del ventilador interior Error EEPROM E1 E2 E3 E4 E5 E6 E7 E8 E9 EE Código de error CW Descripción de error El sensor de habitación abierto o corto Sensor de agua de la tubería abierto o corto Fallo de temperatura de tubería de agua Temperatura de tubería de agua mala/defectuosa Error de bomba de agua Error de hardware (interruptor de clavija de tacto corto) Error de respuesta del ventilador interior E1 E2 E4 E5 E6 E8 E9 Diagnosis de Falla (sólo para el tipo invertido) Si se detecta alguna condición anormal , el controlador cableado SLM9 parpadeará el código de error. CÓDIGO DE ERROR 00 A1 A3 SIGNIFICADO C7 NORMAL ERROR EN PCB DE INTERIOR ANORMALIDAD EN BOMBA DE DRENAJE ANTICONGELACIÓN (FRÍO)/SOBRECALENTAMIENTO DEL INTERCAMBIADOR DE CALOR (CALOR) ANORMALIDAD EN MOTOR DE VENTILADOR INTERIOR ANORMALIDAD DEL LIMPIADOR DE AIRE ELÉCTRICO TERMISTOR DEL INTERCAMBIADOR DE CALOR (1) INTERIOR EN CORTO/ABIERTO TERMISTOR DEL INTERCAMBIADOR DE CALOR (2) INTERIOR EN CORTO/ABIERTO ERROR DEL INTERRUPTOR DE LÍMITE DE REJILLA C9 TERMISTOR HABITACIÓN EN CORTO/ABIERTO A5 A6 AH C4 C5 4 CÓDIGO DE ERROR H7 H8 H9 J1 J3 J5 J6 J7 J8 J9 L1 L3 L4 L5 L8 L9 LC P1 P4 PJ U0 U2 U4 U7 UA UF UH ERROR DE PCB EXTERIOR PROTECCIÓN DE ALTA PRESIÓN PROTECCIÓN DE BAJA PRESIÓN BLOQUEO DEL MOTOR DEL COMPRESOR/COMPRESOR SOBRECARGADO ERROR DE ARRANQUE DEL COMPRESOR MOTOR VENTILADOR CC EXTERIOR TRABADO SOBRECORRIENTE EN ENTRADA DE CA ERROR EXV ERROR EN VÁLVULA DE 4 VÍAS SOBRECALENTAMIENTO TUBERÍA DE DESCARGA SOBRECALENTAMIENTO DEL INTERCAMBIADOR DE CALOR ERROR DEL SISTEMA DEL SENSOR DEL COMPRESOR ERROR DEL INTERRUPTOR DE ALTA PRESIÓN ERROR DE DETECCIÓN DE RESPUESTA DEL COMPRESOR MOTOR DEL VENTILADOR SOBRECARGADO/SOBRETENSIÓN/ ANORMALIDAD DEL SENSOR ERROR EN SENSOR DE CORRIENTE ALTERNA TERMISTOR DE AIRE EXTERIOR EN CORTO/ABIERTO ERROR DEL SENSOR DE PRESIÓN TUBERÍA DESCARGA DEL COMPRESOR EN CORTO/ABIERTO/MAL COLOCADO TERMISTOR DEL TUBO DE SUCCIÓN EN CORTO/ABIERTO TERMISTOR DEL INTERCAMBIADOR DE CALOR EXTERNO EN CORTO/ ABIERTO TERMISTOR DEL INTERCAMBIADOR DE CALOR DE SUBREFRIGERACIÓN EN CORTO/ABIERTO TERMISTOR DEL TUBO DE LÍQUIDO EN CORTO/ABIERTO TERMISTOR DEL TUBO DE GAS EN CORTO/ABIERTO ERROR DE PCB EXTERIOR DEL INVERSOR SOBRECALENTAMIENTO DE LA CAJA DE CONTROL EXTERIOR SOBRECALENTAMIENTO DEL DISIPADOR TÉRMICO ERROR DE IPM/ERROR DE IGBT SOBRETENSIÓN DEL COMPRESOR INVERSOR PREVENCIÓN DE SOBRETENSIÓN DEL COMPRESOR ERROR DE COMUNICACIÓN (PCB DE CONTROL EXTERIOR Y PCB INVERSOR) FASE ABIERTA O DESEQUILIBRIO DE TENSIÓN TERMISTOR DEL DISIPADOR TÉRMICO EN CORTO/ABIERTO ERROR DE CONFIGURACIÓN DE CAPACIDAD GAS INSUFICIENTE TENSIÓN DE CC FUERA DE RANGO ERROR DE COMUNICACIÓN ERROR DE COMUNICACIÓN (PCB DE CONTROL EXTERIOR Y PCB IPM) ERROR DE INSTALACIÓN DISCORDANCIA DE INSTALACIÓN DE TUBERÍA Y CABLEADO/CABLEADO INCORRECTO/ GAS INSUFICIENTE ANTICONGELACIÓN (OTRAS HABITACIONES) 5 ESPAÑOL E1 E3 E4 E5 E6 E7 E8 E9 EA F3 F6 HO H3 H6 SIGNIFICADO 2.0 AJUSTE DE HARDWARE La unidad tiene 2 puentes para controlar la función de la placa. Tabla 2,0 : Resumen de ajustes de hardware OPCIÓN Con puente Sin puente Establecer rango de temperatura Establecer rango de temperatura de 20°C – 30°C Establecer rango de temperatura de 16°C – 30°C (Por defecto) TURBO_QUIET Deshabilitar velocidad de ventilador turbo y silencio (Por defecto) Habilitar velocidad de ventilador turbo y silencio * Solo aplicable al modelo con funciones Turbo o Silencio. 3.0 INSTALACIÓN 3.1 Accesorios Los siguientes accesorios están incluidos junto con este manual. Si falta alguna pieza, contacte a su distribuidor inmediatamente. 1. Control remoto 2. Tornillo de madera (2 piezas) & Tornillo de máquina (2 piezas) 3. Manual de Instrucciones 4. Batería 3.2 Guía Paso a Paso I. Primero abra el gancho en la parte alta del controlador seguido del gancho inferior. Extraiga la cubierta superior del controlador de la cubierta inferior. II. Fije la cubierta inferior a la pared con los dos tornillos provistos. A continuación introduzca el cable de conexión a través de la ranura en la cubierta central superior tal y como se muestra. III. Vuelva a insertar el gancho inferior primero y a continuación encaje el cierre de la parte superior. Hilos de conexión LCD remoto (Caja superior) MOD E TURB O SWIN G DELA Y TIMER QUIE T TIMER TIMER FAN SLEE P ON / OFF 2 x Tornillo de madera 6 LCD Remoto (Cubierta Inferior) EL MEMORÁNDUM Показания устройства BRC51A61/62 ON 12 OFF 12 MON TUE WED THU FRI SAT SUN ALL AUTO OVERRIDE 12 DRY 3 2 1 MODE 10 9 11 8 NO AUTO COOL TURBO QUIET DELAY TIMER HEAT FAN SWING SLEEP F C SET TEMP. TURBO SWING TIMER TIMER ON AM PM OFF FAN 4 5 QUIET SLEEP ON / OFF КНОПКА 6 7 12 13 ФУНКЦИЯ 1. MODE Выбор режима работы (Cool (охлаждение) / Heat (обогрев) / Auto (авто) / Dry (осушение) / Fan (вентилятор)) 2. TURBO Активация/деактивация функции “Турбо” 3. SWING Активация/деактивация качания жалюзи Удерживайте кнопку, чтобы сменить режим поворота жалюзи. 4. QUIET Активация/деактивация функции “Бесшумная” 5. SET TEMP UP Увеличение заданной температуры в °C или °F 6. SET TEMP DOWN Уменьшение заданной температуры в °C или °F 7. SLEEP Активация/деактивация функции “Сон” 8. OFF TIMER Включение/выключение режима установки ВЫКЛ ТАЙМЕРА Событий 1 и 2 9. ON TIMER Включение/выключение режима установки ТАЙМЕРА ВКЛ. Событий 1 и 2 10. DELAY TIMER Активация/деактивация таймера отсрочки 11. FAN Выбор оборотов вентилятора (Auto (авто)/ High (Высок)/ Med (Сред)/ Low (Низк)) 12. ON/OFF Включение/выключение блока независимо от установок таймеров 13. ЧАСЫ РЕАЛЬНОГО ВРЕМЕНИ (ЧРВ) Включить/выключить режим настройки Часов реального времени (ЧРВ) ПРИМЕЧАНИЕ: Функция “Турбо” и “Бесшумная” - только для выбранных моделей. i РУКОВОДСТВО ПО ПРИМЕНЕНЕНИЮ 1.1 Кнопка MODE (РЕЖИМ) Для переключения режимов работы COOL (ХОЛОД), HEAT* (ОБОГРЕВ), AUTO* (АВТО), DRY* (ОСУШЕНИЕ), FAN (ВЕНТИЛЯЦИЯ) нажмите кнопку MODE. Проверьте дисплей для просмотра пульта, в каком режиме он установлен. *HEAT (ОБОГРЕВ), AUTO (АВТО) и DRY (ОСУШЕНИЕ) доступны только для выбранных моделей. 1.2 Скорость вентилятора TURBO (ТУРБО) Нажмите кнопку TURBO один раз, чтобы активировать интенсивную скорость вентилятора. На дисплее появится символ интенсивной скорости. Для выключения интенсивной скорости вентилятора и возврата к предыдущей скорости вентилятора еще раз нажмите кнопку Turbo. При нажатии кнопки FAN (ВЕНТИЛЯЦИЯ) или QUIET или выключении устройства интенсивная скорость выключается. Эта скорость применима только во время работы в режиме COOL (ХОЛОД) и HEAT (ОБОГРЕВ) для выбранных моделей. 1.3 Автоматический поворот направления жалюзи • Нажмите кнопку SWING (ПОВОРОТ) для включения функции автоматического поворота жалюзи. • Для распространения воздуха в определенном направлении, нажмите кнопку SWING (ПОВОРОТ) и ждите до тех пор, пока жалюзи не установится в желаемом направлении, и вновь нажмите кнопку один раз. Метод выбора режима поворота (в зависимости от модели) Режим поворота 2 Режим поворота 3 SWING MODE (РЕЖИМ ПОВОРОТА) активируется только при активации SWING . Поворот указывается символом: • Если в течение 4 секунд не происходит смены режима, устройство будет работать в соответствии с выбранным режимом поворота SWING MODE ( ) (РЕЖИМ ПОВОРОТА). 1.4 QUIET (БЕСШУМНАЯ) скорость вентилятора Нажмите кнопку QUIET один раз, чтобы активировать бесшумную скорость вентилятора. На дисплее появится символ бесшумной скорости. Для выключения бесшумной скорости вентилятора и возврата к предыдущей скорости вентилятора еще раз нажмите кнопку QUIET. При нажатии кнопки FAN (ВЕНТИЛЯЦИЯ) или TURBO или выключении устройства бесшумная скорость выключается. Эта скорость применима только во время работы в режиме COOL и HEAT для выбранных моделей. 1.5 Кнопка Установки Температуры “ ” или “ ” Нажмите кнопку температуры и установите желаемую температуру, нажимая кнопку “ ” или “ ” один раз, при этом температура будет меняться на 1°C или 1°F. Диапазон установки варьируется от 16°С до 30°С (от 60°F до 86°F). При установке опции 20 - 30°C граница диапазона температур устанавливается на 20°C и на 30°C (от 68°F до 86°F). Одновременное нажатие обеих кнопок переключает настройку температуры между °C и °F. Установка температуры во время работы в режиме FAN (ВЕНТИЛЯЦИЯ) невозможна (Отсутствует дисплей установки температуры). Дисплей температуры в помещении отсутствует. 1.6 Функция SLEEP (СОН) Нажмите кнопку SLEEP, чтобы активировать функцию сна. Функция SLEEP недоступна в режимах DRY (ОСУШЕНИЕ) и FAN (ВЕНТИЛЯЦИЯ). 1.7 “ON TIMER (ТАЙМЕР ВКЛ.)” и “OFF TIMER (ТАЙМЕР ВЫКЛ.)” Устройство имеет таймер на 2 события: Таймер 1 и Таймер 2, при этом каждое событие имеет ON TIMER и OFF TIMER Результаты нажатия кнопки для Таймер ВКЛ. и Таймер ВЫКЛ. представлены в Tаблице 1,1. 1 Перевод оригинальных инструкций Режим поворота 1 РУCCKИЙ • Нажимайте кнопку SWING ( ) (ПОВОРОТ) в течение 4 секунд, чтобы войти в режим настройки поля. При настройке поле отображается только режим SWING MODE ( ) (РЕЖИМ ПОВОРОТА). • Нажмите кнопку настройки температуры и , чтобы выбрать вращение SWING MODE ( ) (РЕЖИМ ПОВОРОТА) от режима поворота 1 до режима поворота 3. • Имеется 3 различных SWING MODE (РЕЖИМА ПОВОРОТА), а именно: Таблица 1,1 : Нажатие кнопок Таймер ВКЛ. и Таймер ВЫКЛ. и последовательность событий. КНОПКА TIMER ON ON TIMER 1 ON TIMER 2 Деактивирован Деактивирован Активирован Деактивирован Деактивирован Активирован Активирован Активирован КНОПКА TIMER OFF OFF TIMER 1 OFF TIMER 2 Деактивирован Деактивирован Активирован Деактивирован Деактивирован Активирован Активирован Активирован Все таймеры срабатывают по наступлению определенного события. Кнопка ON/OFF и функция “Приоритет” отменяют действие таймеров. Установка таймеров События 1 и События 2 Действия для Таймера ВКЛ. и Таймера ВЫКЛ. идентичны. 1. Нажмите и удерживайте кнопку Таймера ON/OFF в течение 3 секунд, чтобы войти в режим настройки таймера. (Будет мигать значок ON 1 или OFF 1) 2. Нажмите UP или DOWN, чтобы выбрать Таймер 1 или Таймер 2 для установки. (Мигающий знак ‘1’ указывает на то, что в настоящий момент выбран Таймер 1, мигающий знак ‘2’ указывает на то, что в настоящий момент выбран Таймер 2) 3. Нажмите кнопку Таймер ON/OFF еще раз, чтобы подтвердить. (Затем будет мигать индикация дня недели) 4. Нажмите UP или DOWN, чтобы выбрать день недели. 5. Нажмите кнопку Таймер ON/OFF еще раз, чтобы подтвердить день недели. (Затем будет мигать индикация часа) 6. Нажмите UP или DOWN, чтобы изменить значение часа. 7. Нажмите кнопку Таймер ON/OFF еще раз, чтобы подтвердить час. (Затем будет мигать индикация минут) 8. Нажмите UP или DOWN, чтобы изменить значение минут. 9. Нажмите кнопку Таймер ON/OFF еще раз, чтобы подтвердить минуты. Установка каждого таймера (Таймер 1 ВКЛ. или Таймер 1 ВЫКЛ., или Таймер 2 ВКЛ., или Таймер 2 ВЫКЛ.) осуществляется отдельно при условии выполнения всех 7 шагов. Если во время установки таймера в течение 5 секунд не будет выполнена ни одна операция с кнопками, произойдет автоматический выход из режима установки, и изменения не будут применены. Таймер ON/OFF будет проверяться каждую минуту. Не рекомендуется устанавливать ON TIMER и OFF TIMER на одинаковые значения. В противном случае произойдет срабатывание действующего таймера в соответствии с приоритетностью, указанной в Tаблице 1,2. Например: Настройки ON TMR 2 : DAY – TUE, TIMER – 5.00pm Настройки OFF TMR 1 : DAY – TUE, TIMER – 5.00pm Выход при достижении RTC 5.00pm во TUE: – если устройство включено, нет срабатывания. – если устройство выключено, устройство инициирует включение. Таблица 1,2 : Приоритетность таймера Приоритетность Таймера 1 (Самая высокая) ONTMR2 2 OFFTMR2 3 ONTMR1 4 (Самая низкая) OFFTMR1 При приеме ИК сигнала беспроводной ИК пульт дистанционного управления отключит настройки ON TIMER 2 и OFF TIMER 2. 2 1.8 Функция DELAY TIMER (ТАЙМЕРА ОТСРОЧКИ) Одно нажатие кнопки DELAY TIMER активирует функцию таймера отсрочки на 1 час. На ЖКД появится индикация “OVERRIDE”. При повторном нажатии этой же кнопки устанавливается значение 2 часа. Появится индикация “OVERRIDE”. Еще одно нажатие отключает функцию таймера отсрочки. После выполнения таймера отсрочки функция таймера отсрочки деактивируется, и логотип выключается. Все другие таймеры будут возобновлены. 1.9 Функция скорости FAN (ВЕНТИЛЯТОРА) Скорость вентилятора можно изменить посредством нажатия кнопки FAN: Низк > Сред > Высок > Авто *Функция скорости FAN недоступна в режиме DRY. 1.10 Кнопка ON/OFF (ВКЛ/ВЫКЛ) Начало работы: – При нажатии кнопки ON/OFF ЖКД отобразит полный дисплей и устройство включится. Прекращение работы: – При нажатии кнопки ON/OFF ЖКД отобразит часы реального времени, и устройство выключится. 1.11 Настройки включения питания Блок: Режим: Скорость вентилятора: RTC: Поворот жалюзи: Режим поворота: Таймеры: Турбо: Бесшумная: Сон: Отключение: Выкл Охлаждение Высокая 12:00AM, MONDAY Выкл стандартная Выключены Выключены Выкл Выкл Выключены 1.12 Дисплей часов реального времени (RTC) ЧРВ отображаются на экране во время ON (ВКЛЮЧЕНИЯ) или OFF (ВЫКЛЮЧЕНИЯ) устройства, за исключением случаев перебоя в подаче электроэнергии или индикации кода ошибки. Установка настройки RTC 1. При однократном нажатии кнопки RTC включается режим настройки RTC. (Будет мигать день недели) 2. Нажмите UP или DOWN, чтобы выбрать день недели. 3. Нажмите RTC еще раз, чтобы подтвердить день недели. (Затем будет мигать индикация часа) 4. Нажмите UP или DOWN, чтобы изменить значение часа. 5. Нажмите RTC еще раз, чтобы подтвердить час. (Затем будет мигать индикация минут) 6. Нажмите UP или DOWN, чтобы изменить значение минут. 7. Нажмите RTC еще раз, чтобы подтвердить минуты. ЧРВ будут установлены только после выполнения всех 7 шагов. Если во время установки ЧРВ в течение 5 секунд не будет выполнена ни одна операция с кнопками, произойдет автоматический выход из режима установки, и изменения не будут применены. 1.13 Блокировка Функция блокировки служит для предотвращения изменений настроек. Одновременное нажатие и удерживание кнопок TURBO и QUIET в течение 5 секунд активирует/деактивирует функцию блокирования кнопок; на ЖКД появится/исчезнет индикация “KEYLOCK”. Когда активирована функция блокировки, не работают никакие кнопки, кроме кнопок ON/OFF, TURBO и QUIET (разблокировать). 3 РУCCKИЙ Во время включения питания устройство запустится с последней заданной настройкой главной платы. Если последняя заданная информация недоступна, устройство будет использовать настройки по умолчанию. Настройками по умолчанию являются следующие настройки: 1.14 Резервная батарея Резервная батарея используется для того, чтобы сохранять настройки ЧРВ и 7-дневного программируемого таймера при отсутствии напряжения в электросети минимум на 1 месяц для каждого нового комплекта установленных батареек. Для агрегатов, не оборудованных резервной батареей, ЧРВ после включения электропитания автоматически показывают 12:00 Понедельника, а таймеры обнуляются. 1.15 Индикатор ошибки При обнаружении любого ненормального условия на дисплее появляется код ошибки. Код ошибки отображается с помощью сегментов ЧРВ (мигание), что означает, что при возникновении ошибки вместо кода ошибки не будут отображаться ЧРВ. Формат кода ошибки будет следующим: Код ошибки DX Описание ошибки Комнатный датчик отключен или короткое замыкание Датчик внутреннего змеевика открыт Датчик наружного змеевика открыт Перегрузка компрессора/Короткое замыкание/датчика внутреннего змеевика Низкий уровень заряда хладагента/Утечка газа/на открытом воздухе ненормальное Неисправность водяного насоса Имеется датчик наружного змеевика (Модель MS) Аппаратная ошибка (Короткое замыкание штыря тактовой кнопки) Ошибка обратной связи внутреннего вентилятора Ошибка EEPROM E1 E2 E3 E4 E5 E6 E7 E8 E9 EE Код ошибки CW Описание ошибки Комнатный датчик отключен или короткое замыкание Датчик трубопровода отключен или короткое замыкание Недостаточная температура трубопровода Ненадлежащая/ошибочная температура трубопровода Ошибка водяного насоса Аппаратная ошибка (Короткое замыкание штыря тактовой кнопки) Ошибка обратной связи внутреннего вентилятора E1 E2 E4 E5 E6 E8 E9 Диагностика неисправностей (только для инверторного типа) При обнаружении любого ненормального состояния проводной контроллер SLM 9 начнет мигать, указывая на код ошибки КОД ОШИБКИ 00 A1 A3 A5 A6 AH C4 C5 C7 C9 КОДА НОРМАЛЬНЫЙ ОШИБКА ПЛАТЫ ВНУТРЕННЕГО БЛОКА НЕИСПРАВНОСТЬ ДРЕНАЖНОГО НАСОСА АНТИФРИЗ (ОХЛАЖДЕНИЕ)/ПЕРЕГРЕВ ТЕПЛООБМЕННИКА (ОБОГРЕВ) НЕИСПРАВНОСТЬ ДВИГАТЕЛЯ ВЕНТИЛЯТОРА ВНУТРЕННЕГО БЛОК ЭЛЕКТРИЧЕСКАЯ НЕИСПРАВНОСТЬ ВОЗДУХООЧИСТИТЕЛЯ ТЕРМОРЕЗИСТОР ТЕПЛООБМЕННИКАВНУТРЕННЕГО БЛОКА (1)ЗАМКНУТ/ РАЗОМКНУТ ТЕРМОРЕЗИСТОР ТЕПЛООБМЕННИКАВНУТРЕННЕГО БЛОКА (2)ЗАМКНУТ/ РАЗОМКНУТ ОШИБКА КОНЦЕВОГО ВЫКЛЮЧАТЕЛЯ ЖАЛЮЗИ ТЕРМОРЕЗИСТОР ВНУТРЕННЕГО БЛОКА ЗАМКНУТ/РАЗОМКНУТ 4 J3 J5 J6 J7 J8 J9 L1 L3 L4 L5 L8 L9 LC P1 P4 PJ U0 U2 U4 U7 UA UF UH КОДА ОШИБКА ПЕЧАТНОЙ ПЛАТЫНАРУЖНОГО БЛОКА ЗАЩИТА ВЫСОКОГО ДАВЛЕНИЯ ЗАЩИТА НИЗКОГО ДАВЛЕНИЯ БЛОКИРОВКА ДВИГАТЕЛЯ КОМПРЕССОРА/ПЕРЕГРУЗКА КОМПРЕССОРА ОШИБКА ЗАПУСКА КОМПРЕССОРА БЛОКИРОВКА ВЕНТИЛЯТОРНОГО ДВИГАТЕЛЯ ПРЯМОГО ТОКА НАРУЖНОГО БЛОКА СВЕРХТОК ВХОДНОГО ПЕРЕМЕННОГО ТОКА ОШИБКА EXV ОШИБКА 4-X ХОДОВОГО КЛАПАНА ПЕРЕГРЕВ ВЫПУСКНОЙ ТРУБЫ ПЕРЕГРЕВ ТЕПЛООБМЕННИКА СИСТЕМНАЯ ОШИБКА ДАТЧИКА КОМПРЕССОРА ОШИБКА РЕЛЕ ВЫСОКОГО ДАВЛЕНИЯ ОШИБКА ДЕТЕКЦИИ ОБРАТНОЙ СВЯЗИ КОМПРЕССОРА ПЕРЕГРУЗКА ДВИГАТЕЛЯ ВЕНТИЛЯТОРА/ПЕРЕГРУЗКА ПО ТОКУ/ОШИБКА ДАТЧИКА ОШИБКА ДАТЧИКА ПЕРЕМЕННОГО ТОКА ТЕРМИСТОР НАРУЖНОГО ВОЗДУХА ЗАМКНУТ/ОТКРЫТ ОШИБКА ДАТЧИКА ДАВЛЕНИЯ ТЕРМИСТОР ВЫПУСКНОЙ ТРУБЫ КОМПРЕССОРА ЗАМКНУТ/ОТКРЫТ/ НЕПРАВИЛЬНО УСТАНОВЛЕН ТЕРМОРЕЗИСТОР ВСАСЫВАЮЩЕЙ ТРУБЫ ЗАМКНУТ/РАЗОМКНУТ ТЕРМИСТОР ТЕПЛООБМЕННИКА НАРУЖНОГО БЛОКА ЗАМКНУТ/ОТКРЫТ ТЕРМОРЕЗИСТОР ПЕРЕОХЛАЖДЕНИЯ ЗАМКНУТ/РАЗОМКНУТ ТЕРМИСТОР ЖИДКОСТНОЙ ТРУБЫ ЗАМКНУТ/ОТКРЫТ ТЕРМИСТОР ГАЗОВОЙ ТРУБЫ ЗАМКНУТ/ОТКРЫТ ОШИБКА ПЛАТЫ ПРЕОБРАЗОВАТЕЛЯ НАРУЖНОГО БЛОКА ПЕРЕГРЕВ КОРОБКИ УПРАВЛЕНИЯ НАРУЖНОГО БЛОКА ПЕРЕГРЕВ РАДИАТОРА ОШИБКА IPM /ОШИБКА IGBT ПЕРЕГРУЗКА ПО ТОКУ ПРЕОБРАЗОВАТЕЛЯ КОМПРЕССОРА ПРЕДОТВРАЩЕНИЕ ПЕРЕГРУЗКИ ПО ТОКУ КОМПРЕССОРА ОШИБКА СВЯЗИ (ПЛАТ УПРАВЛЕНИЯ НАРУЖНОГО БЛОКА И ПЛАТА ПРЕОБРАЗОВАТЕЛЯ) ОБРЫВ ФАЗЫ ИЛИ НЕСБАЛАНСИРОВАННОСТЬ НАПРЯЖЕНИЯ ТЕРМИСТОР РАДИАТОРА ЗАМКНУТ/ОТКРЫТ ОШИБКА УСТАНОВКИ ПРОИЗВОДИТЕЛЬНОСТИ НЕДОСТАТОЧНО ГАЗА НЕДОПУСТИМОЕ ЗНАЧЕНИЕ НАПРЯЖЕНИЯ ПОСТОЯННОГО ТОКА ОШИБКА КОММУНИКАЦИИ ОШИБКА КОММУНИКАЦИИ (ПЕЧАТНАЯ ПЛАТА И ПЕЧАТНАЯ ПЛАТА ИСМ НАРУЖНОГО УПРАВЛЕНИЯ) ОШИБКА УСТАНОВКИ НЕСООТВЕТСТВИЕ ТРУБОПРОВОДА И ПРОВОДКИ / НЕСООТВЕТСТВУЮЩАЯ ПРОВОДКА НЕДОСТАТОЧНО ГАЗА АНТИФРИЗ (ДРУГИЕ ПОМЕЩЕНИЯ) 5 РУCCKИЙ КОД ОШИБКИ E1 E3 E4 E5 E6 E7 E8 E9 EA F3 F6 HO H3 H6 H7 H8 H9 J1 2.0 НАСТРОЙКА ОБОРУДОВАНИЯ Для управления функцией панели устройство имеет опцию 2 перемычек. Таблица 2,0 : Сводная информация о настройках оборудования ОПЦИЯ С перемычкой Без перемычки Установка диапазона темп. Установка диапазон темп. от 20°C до 30°C Установка диапазон темп. от 16°C до 30°C (настройка по умолчанию) ТУРБО_ БЕСШУМН Выключение турбо и бесшумной скорости вентилятора (настройка по умолчанию) Включение турбо и бесшумной скорости вентилятора * Применимо только к модели со встроенными функциями Турбо или Бесшумной скорости. 3.0 УСТАНОВКЕ 3.1 Принадлежности Нижеследующие принадлежности поставляются вместе с этим руководством. Если что-либо отсутствует, то немедленно обращайтесь к Вашему дилеру. 1. Пульт дистанционного управления 2. Шуруп (2 штуки) и крепежный винт (2 штуки) 3. Руководство по установке 4. Батарея 3.2 Подробное Руководство I. Откройте сначала фиксатор, расположенный на верхней части пульта, затем нижний фиксатор. Снимите верхнюю панель пульта с нижней панели. II. Закрепите нижнюю панель на стене с помощью 2 имеющихся шурупов. Затем проденьте соединительный провод через отверстие, расположенное на верхней центральной панели, как показано. III. Вставьте обратно сначала нижний фиксатор, затем защелкните верхнюю часть. Соединительные провода Удаленный ЖКД (Верхний ящик) MOD E TURB O SWIN G DELA Y TIMER QUIE T TIMER TIMER FAN SLEE P ON / OFF 2 х Шуруп Удаленный ЖКД (Нижняя Часть) 6 ПАMЯTKA BRC51A61/62 Denetleyici Gösterimi AUTO ON 12 OFF 12 MON TUE WED THU FRI SAT SUN ALL OVERRIDE 12 DRY 3 2 1 MODE 10 9 11 8 NO AUTO COOL TURBO QUIET DELAY TIMER HEAT FAN SWING SLEEP F C SET TEMP. TURBO SWING TIMER TIMER ON AM PM OFF FAN 4 5 QUIET SLEEP ON / OFF TUŞ 6 7 12 13 İŞLEV 1. MODE Çalıştırma modu kontrolünü seçer (Cool (Soğuk) / Heat (Sıcak) / Auto (Otomatik) / Dry (Kuru) / Fan) 2. TURBO Turbo fonksiyonunu ektinleştirir/devre dışı bırakır 3. SWING Hava yönlendirme kontrolünü etkinleştirir/ devre dışı bırakır Salınım Modunu değiştirmek için Tuşu basılı tutun 4. QUIET Sessiz çalışmayı etkinleştirir/devre dışı bırakır 5. SET TEMP UP Ayarlanan sıcaklığı °C veya °F olarak artırır 6. SET TEMP DOWN Ayarlanan sıcaklığı °C veya °F olarak azaltır 7. SLEEP Uyku fonksiyonunu etkinleştirir/devre dışı bırakır 8. OFF TIMER Durum 1 ve 2 OFF TIMER (Zamanlayıcı kapalı) ayar modunu seçer/iptal eder 9. ON TIMER Durum 1 ve 2 ON TIMER (Zamanlayıcı açık) ayar modunu etkinleştirir/devre dışı bırakır 10. DELAY TIMER Geciktirme zamanlayıcısını etkinleştirir/devre dışı bırakır 11. FAN Fan hızı kontrolünü seçer (Auto (Otomatik)/ High (Yüksek)/ Med (Orta)/ Low (Düşük)) 12. ON/OFF Bütün zaman ayarlarını iptal ederek üniteyi açar/kapar 13. GERÇEK ZAMANLI SAAT (RTC) Gerçek zamanlı saat (RTC) ayar modunu seçer/iptal eder NOT: Turbo ve sessiz fonksiyonu yalnızca belirli modellerde bulunur. i KULLANIM TALİMATI 1.1 MODE Düğmesi Çalışmayı COOL (SOĞUK), HEAT* (SICAK), AUTO* (OTOMATIK), DRY* (KURU), FAN konumundan değiştirmek için MODE düğmesine basın. Kontrolün hangi moda ayarlandığını anlamak için ekranı kontrol edin. *HEAT (SICAK), AUTO (OTOMATIK) ve DRY (KURU) yalnızca belirli modellerde bulunur. 1.2 TURBO Fan Hızı Turbo fan hızını etkinleştirmek için, TURBO tuşuna bir defa basın. Turbo sembolü gösterilir. Turbo fan hızını devre dışı bırakmak ve önceki fan hızına geri dönmek için, Turbo tuşuna bir defa basın. Kullanıcı FAN düğmesine veya QUIET düğmesine basar ya da üniteyi kapatırsa, turbo hızı devre dışı bırakılacaktır. Bu hız yalnızca belirli modellerde COOL (SOĞUK) ve HEAT (SICAK) modundayken geçerlidir. 1.3 Otomatik Hava Yönlendirme • Otomatik hava yönlendirme fonksiyonunu harekete geçirmek için SWING (SALINIM) düğmesine basın. • Havayı belirli bir yönde dağıtmak için, SWING (SALINIM) düğmesine basın ve kanat istenilen yöne hareket edene kadar bekleyin ve düğmeye tekrar bir kez basın. Salınım modu seçim yöntemi (modele bağlıdır) • Alan ayarlama moduna girmek için SWING ( ) (SALINIM) düğmesine 4 saniye boyunca basın. Alan ayarı modundayken sadece SWING MODE ( ) (SALINIM MODU’NU) gösterecektir. • SWING MODE ( ) (SALINIM MODU’NU) Salınım Modu 1’den Salınım Modu 3’e geçirmek için sıcaklık ve düğmesine basın. • 3 farklı SALINIM MODU vardır, bunlar: Salınım modu 1 Salınım modu 2 Salınım modu 3 SWING MODE, SWING (SALINIM MODU’NU, SALINIM) etkin olmadıkça devreye girmeyecektir. Salınım yandaki logo ile gösterilir: • Mod 4 saniye içinde değişmezse, ünite seçili SWING MODE ( ) (SALINIM MODU’NU) göre çalışacaktır. Sessiz fan hızını etkinleştirmek için, QUIET tuşuna bir defa basın. QUIET sembolü gösterilir. Sessiz fan hızını devre dışı bırakmak ve önceki fan hızına geri dönmek için, tekrar QUIET tuşuna basın. Kullanıcı FAN düğmesine veya TURBO düğmesine basar ya da üniteyi kapatırsa, sessiz hız devre dışı bırakılacaktır. Bu hız yalnızca belirli modellerde COOL (SOĞUK) ve HEAT (SICAK) modundayken geçerlidir. 1.5 “ ” veya “ ” Ayarlanan Sıcaklık Düğmesi Sıcaklık düğmesine basın ve “ ” veya “ ” düğmesine bir defa basarak seçtiğiniz sıcaklığı ayarlayın, sıcaklık 1°C veya 1°F olarak değişir. Varsayılan sıcaklık ayarı aralığı, 16°C ila 30°C (60°F ila 86°F) arasındadır. 20 - 30ºC Seçeneği ayarlandığında, sıcaklık aralığı sınırı 20ºC ila 30ºC (68°F ila 86°F) olarak ayarlanır. Her iki tuşa aynı anda basıldığında, sıcaklık ayarı ºC ve ºF arasında değişecektir. FAN modu sırasında sıcaklık ayarına izin verilmez (Ayarlanan sıcaklık göstergesi yok). Oda göstergesi sıcaklığı yoktur. 1.6 SLEEP Fonksiyonu Uyku modunu etkinleştirmek için, SLEEP düğmesine basın. DRY (KURU) modunda ve FAN modunda SLEEP fonksiyonu kullanılamaz. 1.7 “ON TIMER” ve “OFF TIMER” Ünite Zamanlayıcı 1 ve Zamanlayıcı 2 adında 2 durumlu zamanlayıcıya sahiptir, her zamanlayıcıda ON TIMER (Zamanlayıcı Açık) ve OFF TIMER (Zamanlayıcı Kapalı) vardır. Zamanlayıcı AÇIK ve Zamanlayıcı KAPALI için tuş basma etkinliği Tablo 1,1'de gösterilmektedir. 1 TÜRKÇE QUIET Fan Hızı Orijinal talimatların çevirisi 1.4 Tablo 1,1: Zamanlayıcı AÇIK ve Zamanlayıcı KAPALI tuş basma ve durum sekansı. TIMER ON KEY (TIMER ON TUŞU) AÇIK Zamanlayıcı 1 TIMER OFF KEY (TIMER OFF TUŞU) AÇIK Zamanlayıcı 2 KAPALI Zamanlayıcı 2 KAPALI Zamanlayıcı 2 Devre dışı bırakıldı Devre dışı bırakıldı Devre dışı bırakıldı Devre dışı bırakıldı Etkinleştirildi Devre dışı bırakıldı Etkinleştirildi Devre dışı bırakıldı Devre dışı bırakıldı Etkinleştirildi Devre dışı bırakıldı Etkinleştirildi Etkinleştirildi Etkinleştirildi Etkinleştirildi Etkinleştirildi Bütün zamanlayıcılar durum tetiklemeli zamanlayıcılardır ve ON/OFF düğmesine basılarak ve Çıkış fonksiyonu ile çıkılabilir. Durum 1 ve Durum 2 Zamanlayıcılarının Ayarlanması Zamanlayıcı AÇIK ve Zamanlayıcı KAPALI işlemi aynıdır. 1. Zamanlayıcı ayarlama moduna girmek için, Zamanlayıcı ON/OFF tuşunu 3 saniye basılı tutun. (ON 1 veya OFF 1 simgesi yanıp sönecektir) 2. Zamanlayıcı 1 veya Zamanlayıcı 2'yi ayarlamak üzere seçmek için UP veya DOWN tuşuna basın. (Yanıp sönen '1' o anda Zamanlayıcı 1'in seçili olduğunu, yanıp sönen '2' o anda Zamanlayıcı 2'nin seçili olduğunu gösterir) 3. Onaylamak için tekrar Zamanlayıcı ON/OFF tuşuna basın. (Sonra Gün yanıp sönecektir) 4. Günü seçmek için UP veya DOWN düğmesine basın. 5. Günü onaylamak için Zamanlayıcı ON/OFF düğmesine tekrar basın. (Sonra Saat yanıp sönecektir) 6. Saati değiştirmek için UP veya DOWN düğmesine basın. 7. Saati onaylamak için tekrar Zamanlayıcı ON/OFF tuşuna basın. (Sonra Dakika yanıp sönecektir) 8. Dakikayı değiştirmek için UP veya DOWN düğmesine basın. 9. Dakikayı onaylamak için tekrar Zamanlayıcı ON/OFF düğmesine basın. Her zamanlayıcı (Zamanlayıcı 1 ON veya Zamanlayıcı 1 OFF ya da Zamanlayıcı 2 ON veya Zamanlayıcı 2 OFF) yalnızca tüm 7 adımdan sonra ayrı olarak ayarlanacaktır, zamanlayıcıyı ayarlarken 5 saniye tuş işlemi olmazsa, ayar modunda otomatik olarak çıkacaktır ve hiçbir değişiklik yapılmayacaktır. Her 1 dakikada zamanlayıcı ON/OFF kontrol edilecektir. ON TIMER ve OFF TIMER'I aynı değerlere sahip olacak şekilde ayarlamanız önerilmez. Bu durumda, etkin zamanlayıcı Tablo 1,2'de belirtildiği öncelikle işlenecektir. Örnek: ON TMR 2 ayarları: DAY – TUE, TIMER – 5.00pm OFF TMR 1 ayarları: DAY – TUE, TIMER – 5.00pm RTC PRŞ günü 5.00ös olduğunda sonuçlanır: – ünite açıkken, yanıt yok. – ünite kapalıyken, ünite açık olacak şekilde tetiklenecektir. Tablo 1,2: Zamanlayıcı Önceliği Öncelik Zamanlayıcı 1 (En Yüksek) ONTMR2 2 OFFTMR2 3 ONTMR1 4 (En Düşük) OFFTMR1 IR alındığında, IR kablosuz uzaktan kumanda ON TIMER 2 ve OFF TIMER 2 ayarlarını geçersiz kılacaktır. 2 1.8 DELAY TIMER Fonksiyonu DELAY TIMER tuşuna bir defa basıldığında geciktirme zamanlayıcısı fonksiyonu 1 saat etkinleştirilecektir. LCD'de “OVERRIDE” göstergesi görünecektir. Aynı tuşa tekrar basılması yarı iki saate çıkaracaktır. “OVERRIDE” göstergesi görünecektir. Sonraki basma geciktirme zamanlayıcısı fonksiyonunu devre dışı bırakacaktır. Geciktirme zamanlayıcısı tamamlandıktan sonra, geciktirme zamanlayıcısı fonksiyonu devre dışı bırakılır ve logo KAPALI'dır. Tüm diğer zamanlayıcılar zamanlayıcılar devam ettirilecektir. 1.9 FAN FAN tuşuna basarak fan hızı değiştirilebilir: Düşük > Orta > Yüksek > Otomatik > *FAN hızı DRY modunda kullanılamaz. 1.10 ON/OFF (AÇMA/KAPAMA) Düğmesi Çalıştırma İşlemi: – ON/OFF düğmesine basın, LCD'de tam ekran gösterilir ve ünite açılır. Durdurma İşlemi: – ON/OFF düğmesine basın, LCD'de yalnızca gerçek zamanlı saat gösterilecektir ve ünite kapatılır. 1.11 Güç verme Ayarları Güç verme sırasında, ünite ana kartın son durumunda başlatılacaktır. Son durum bilgisi yoksa, ünite varsayılan ayarları kullanacaktır. Varsayılan ayarlar aşağıdadır: Kapalı Soğuk Yüksek 12:00AM, MONDAY Kapalı Standart Devredışı Devredışı Kapalı Kapalı Devredışı 1.12 Gerçek Zamanlı Saat (RTC) Göstergesi Güç kesilmesi veya hata kodu dışında, ünite ON veya OFF iken RTC ekranda gösterilir. Ayarlanan RTC Ayarı 1. RTC tuşuna bir defa basıldığında, RTC ayar modu etkinleştirilecektir. Gün yanıp sönecektir) 2. Günü seçmek için UP veya DOWN düğmesine basın. 3. Günü onaylamak için tekrar RTC'ye basın. (Sonra Saat yanıp sönecektir) 4. Saati değiştirmek için UP veya DOWN düğmesine basın. 5. Saati onaylamak için tekrar RTC'ye basın. (Sonra Dakika yanıp sönecektir) 6. Dakikayı değiştirmek için UP veya DOWN düğmesine basın. 7. Dakikayı onaylamak için tekrar RTC'ye basın. RTC yalnızca 7 adımın tümü uygulandıktan sonra ayarlanacaktır, RTC ayarı sırasında 5 saniye tuş işlemi olmazsa, otomatik olarak ayar modundan çıkacaktır ve ayarda değişiklik yapılmayacaktır. 1.13 Tuş Kiliti Bu tuş kiliti fonksiyonu her hangi bir ayar değişimini engeller. TURBO ve QUIET tuşlarına 5 saniye basılı tutulduğunda tuş kilidi fonksiyonu etkinleştirilecek/devre dışı bırakılacaktır; LCD'de “KEYLOCK” görünür/kaybolur. Bütün tuşlar kilitliyken, yalnızca ON/OFF, TURBO ve QUIET (kilidi açmak için) tuşuna basılabilir. 3 TÜRKÇE Ünite: Mod: Fan Hızı: RTC: Salınım: Salınım modu: Zamanlayıcılar: Turbo: Sessiz: Uyku: Çıkış: 1.14 Pil Şarj Aygıtı Pil şarj aygıtı, takılan her yeni pil takımı için en az 1 ay sürekli güç kesintisi sırasında RTC ve 7- Gün programlanabilen zamanlayıcı ayarlarını korumak için kullanılır. Pil şarj aygıtsız ünite için, varsayılan ayar Pazartesi günü 12:00 öö olacak ve zamanlayıcı güç gelişi esnasında silinecektir. 1.15 Hata Göstergesi Anormal bir koşul algılandığında, hata kodu gösterilecektir. RTC segmentlerini kullanarak hata kodu gösterilir (yanıp sönme), hata olduğunda, hata kodu yerine RTC gösterilmeyecek demektir. Hata kodu biçimi aşağıdaki gibi olacaktır: DX Hata Kodu Hata Açıklaması Oda Sensörü Açık veya Kapalı İç ünite serpantin algılayıcı devresi açık Dış ünite serpantin algılayıcı devresi açık Kompresörün Yüklenmesi/Iç Ünite Serpantin Algılayıcısı Kısa Devre/Dış Ünite Serpantin Algılayıcısı Kısa Devre Düşük soğutucu akışkan şarjının/Gaz sızıntısı/açık anormal Su Pompası Arızası Dış ünite bobin sensörü mevcut (MS Modeli) Donanım Hatası (Tact Anahtar Pimi Kısa Devre) İç Mekan Fanı Geri Bildirim Hatası EEPROM Hatası E1 E2 E3 E4 E5 E6 E7 E8 E9 EE CW Hata Kodu Hata Açıklaması Oda Sensörü Açık veya Kapalı Şebeke Suyu Sensörü Açık veya Kapalı Şebeke Suyu Sıcaklığı Az Şebek Suyu Sıcaklık Yanlış/Hatalı Su Pompası Hatası Donanım Hatası (Tact Anahtar Pimi Kısa Devre) İç Mekan Fanı Geri Bildirim Hatası E1 E2 E4 E5 E6 E8 E9 Ariza Teşhİsİ (Sadece İnvertör için) Herhangi bir anormal durum algılanırsa, SLM9 kablolu kumandada hata kodu yanıp sönecektir. HATA KODU ANLAMI 00 NORMAL A1 DAHİLİ PCB HATASI A3 TAHLİYE POMPASI ANORMAL A5 ANTİFRİZ (SOĞUTMA) / IŞI EŞANJÖRÜ AŞIRI ISINDI (ISITMA) A6 DAHİLİ FAN MOTORU ANORMAL AH ELEKTRİKLİ HAVA TEMİZLEYİCİSİ ANORMAL C4 DAHILI ISI ESANJÖRÜ (1)TERMİSTÖR KISA/AÇIK C5 DAHILI ISI ESANJÖRÜ (2)TERMİSTÖR KISA/AÇIK C7 PANJUR LİMİT DÜĞMESİ HATASI C9 DAHİLİ ODA TERMİSTÖRÜ KISA/AÇIK 4 ANLAMI E1 DIŞ BDP HATASI E3 YÜKSEK BASINÇ KORUMASI E4 DÜŞÜK BASINÇ KORUMA E5 KOMPRESÖR MOTORU KİLİDİ/KOMPRESÖR AŞIRI YÜKLENDİ E6 KOMPRESÖR ÇALIŞTIRMA HATASI E7 DIŞ DC FAN MOTORU KİLİDİ E8 AC GİRİŞİNDE AŞIRI AKIM E9 EXV HATASI EA 4 YOLLU VALF HATASI F3 BOŞALTMA BORUSU AŞIRI ISINDI F6 ISI EŞANJÖRÜ AŞIRI ISINDI HO KOMPRESÖR SENSÖR SİSTEMİ HATASI H3 YÜKSEK BASINÇ DÜĞMESİNDE HATA H6 KOMPRESÖR GERİBİLDİRİM ALGILAMA HATASI H7 FAN MOTORU AŞIRI YÜKLÜ/AŞIRI AKIM/SENSÖR ANORMAL H8 AC AKIMI SENSÖRÜ HATASI H9 DIŞ HAVA TERMİSTÖRÜ KISA DEVRE YAPTI/AÇIK J1 BASINÇ SENSÖRÜNDE HATA J3 KOMPRESÖR BOŞALTMA BORUSU TERMİSTÖRÜ KISA DEVRE YAPTI/AÇIK/YANLIŞ YERLEŞTİRDİ J5 EMME BORUSU TERMİSTÖRÜ KISA/AÇIK J6 DIŞ ISI EŞANJÖRÜ TERMİSTÖRÜ KISA DEVRE YAPTI/AÇIK J7 ALT SOĞUTMA ISI ESANJÖRÜ TERMİSTÖRÜ KISA/AÇIK J8 SIVI BORUSU TERMİSTÖRÜ KISA DEVRE YAPTI/AÇIK J9 GAZ BORUSU TERMİSTÖRÜ KISA DEVRE YAPTI/AÇIK L1 İNVERTÖR DIŞ ÜNİTE PCB HATASI L3 DIŞ KONTROL KUTUSU AŞIRI ISINDI L4 ISI HAZNESİ AŞIRI ISINDI L5 IPM HATASI/IGBT HATASI L8 İNVERTÖR KOMPRESÖRÜNDE AŞIRI AKIM L9 KOMPRESÖR AŞIRI AKIM ÖNLEME LC İLETİŞİM HATASI (DIŞ KONTROL PCB’Sİ VE İNVERTÖR PCB’Sİ) P1 AÇIK FAZ VEYA VOLTAJ DENGESİZLİĞİ P4 ISI HAZNESİ TERMİSTÖRÜ KISA DEVRE YAPTI/AÇIK PJ KAPASİTE AYARI HATASI U0 YETERSİZ GAZ U2 DC GERİLİMİ ARALIK DIŞI U4 İLETİŞİM HATASI U7 İLETİŞİM HATASI (DIŞ KONTROL BDP VE IPM BDP) UA KURULUM HATASI UF BORU VE KABLO TERTİBATI UYUŞMUYOR/YANLIŞ KABLO TERTİBATI/YETERSİZ GAZ UH ANTİFRİZ (DİĞER ODALAR) 5 TÜRKÇE HATA KODU 2.0 DONANIM AYARI Ünitede kart fonksiyonunu kontrol etmek için 2 bağlantı teli vardır. Tablo 2,0: Donanım Ayarları Özeti SEÇENEK Bağlantı Teli İle Bağlantı Teli Olmadan Ayarlanan Sıcaklık Aralığı 20°C – 30°C arasında ayarlanan sıcaklık aralığı 16°C – 30°C arasında ayarlanan sıcaklık aralığı (Varsayılan) TURBO_QUIET Turbo ve sessiz fan hızını devre dışı bırakır (Varsayılan) Turbo ve sessiz fan hızını etkinleştirir * Yalnızca dahili Turbo ve Sessiz özelliklerine sahip modelde bulunur. 3.0 MONTAJ 3.1 Aksesuarlar Bu kılavuz ile birlikte aşağıdaki aksesuarlar verilmektedir. Eğer her hangi bir parça eksik ise, derhal bayiniz ile temasa geçin. 1. Uzaktan kumanda 2. Ahşap vida (2 adet) & makine vidası (2 adet) 3. Kullanma kılavuzu 4. Pil 3.2 Adım adım montaj I. Önce denetleyicinin üst klipsini ardından alt klipsini açın. Denetleyicinin üst kasasını alt kasadan çıkarın. II. Alt kasayı verilen 2 vida ile duvara sabitleyin. Ardından bağlantı telini gösterildiği gibi üst orta kasadaki yuvadan takın. III. Önce alt klipsi geri takın ve ardından üst kısmı kapatın. Bağlantı kabloları LCD Uzaktan Kumanda (Üst Kapak) MOD E TURB O SWIN G DELA Y TIMER QUIE T TIMER TIMER FAN SLEE P ON / OFF 2 x Ahşap vida 6 LCD Uzaktan Kumanda (Alt kutu) NOT • In the event that there is any conflict in the interpretation of this manual and any translation of the same in any language, the English version of this manual shall prevail. • The manufacturer reserves the right to revise any of the specification and design contain herein at any time without prior notification. • En cas de désaccord sur l’interprétation de ce manuel ou une de ses traductions, la version anglaise fera autorité. • Le fabriquant se réserve le droit de modifier à tout moment et sans préavis la conception et les caractéristiques techniques des appareils présentés dans ce manuel. • Im Falle einer widersprüchlichen Auslegung der vorliegenden Anleitung bzw. einer ihrer Übersetzungen gilt die Ausführung in Englisch. • Änderungen von Design und technischen Merkmalen der in dieser Anleitung beschriebenen Geräte bleiben dem Hersteller jederzeit vorbehalten. • Nel caso ci fossero conflitti nell’interpretazione di questo manuale o delle sue stesse traduzioni in altre lingue, la versione in lingua inglese prevale. • Il fabbricante mantiene il diritto di cambiare qualsiasi specificazione e disegno contenuti qui senza precedente notifica. • En caso de conflicto en la interpretación de este manual, y en su traducción a cualquier idioma, prevalecerá la versión inglesa. • El fabricante se reserva el derecho a modificar cualquiera de las especificaciones y diseños contenidos en el presente manual en cualquier momento y sin notificación previa. • В случае противоречия перевода данного руководства с другими переводами одного и того же текста, английский вариант рассматривается как приоритетный. • Завод-изготовитель оставляет за собой право изменять характеристики и конструкцию в любое время без предварительного уведомления. • Bu kılavuzun anlaşılmasında bir çatışma olduğunda ve farklı dillerdeki tercümeler farklılık gösterdiğinde, bu kılavuzun ıngilizce sürümü üstün tutulacaktır. • Üretici burada bulunan teknik özellikleri ve tasarımları herhangi bir zamanda ve önceden haber vermeden değiştirme hakkını saklı tutar. Zandvoordestraat 300, B-8400 Oostende, Belgium P.O.Box 18674, Galleries 4, 11th Floor, Downtown Jebel Ali, Dubai, UAE. Head office: Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan Tokyo office: JR Shinagawa East Bldg., 2-18-1, Konan, Minato-ku, Tokyo, 108-0075 Japan http://www.daikin.com/global/ Importer for Turkey Hürriyet Mahallesi Yakacık D-100 Kuzey Yanyol Caddesi No:49/1-2 Kartal − İstanbul . ﺗﻜﻮﻥ ﺍﻟﻨﺴﺨﺔ ﺍﻻﻧﻜﻠﻴﺰﻳﺔ ﻫﻲ ﺍﻟﺴﺎﺋﺪﺓ،ﺍﺫﺍ ﺣﺪﺙ ﺍﻱ ﺗﻌﺎﺭﺽ ﻓﻲ ﺗﻔﺴﻴﺮ ﻫﺬﺍ ﺍﻟﻜﺘﻴﺐ ﻭﺍﻱ ﺍﺧﺘﻼﻑ ﻓﻲ ﺍﻟﺘﺮﺟﻤﺔ ﻧﻔﺴﻬﺎ ﺑﺄﻳﺔ ﻟﻐﺔ ﻛﺎﻧﺖ • .ﻳﺤﺘﻔﻆ ﺍﻟﻤﺼﻨﻊ ﺑﺤﻖ ﺗﻌﺪﻳﻞ ﺍﻟﺘﺼﻤﻴﻢ ﻭﺍﻳﺔ ﻣﻮﺍﺻﻔﺎﺕ ﻣﻮﺟﻮﺩﺓ ﻫﻨﺎ ﻓﻲ ﺍﻱ ﻭﻗﺖ ﻣﻦ ﺩﻭﻥ ﺇﺷﻌﺎﺭ ﻣﺴﺒﻖ • Head office: Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan Tokyo office: JR Shinagawa East Bldg., 2-18-1, Konan, Minato-ku, Tokyo, 108-0075 Japan http://www.daikin.com/global/ Zandvoordestraat 300, B-8400 Oostende, Belgium P.O.Box 18674, Galleries 4, 11th Floor, Downtown Jebel Ali, Dubai, UAE. Importer for Turkey Hürriyet Mahallesi Yakacık D-100 Kuzey Yanyol Caddesi No:49/1-2 Kartal − İstanbul ﻣﺬﻛﺮﺓ 2.0 ﺿﺒﻂ ﺍﻷﺟﻬﺰﺓ ﺗﺤﺘﻮﻱ ﺍﻟﻮﺣﺪﺓ ﻋﻠﻰ 2ﻭﺻﻠﺔ ﻋﺒﻮﺭ ﻟﻠﺘﺤﻜﻢ ﻓﻲ ﻭﻇﻴﻔﺔ ﺍﻟﻠﻮﺣﺔ. ﺍﻟﺠﺪﻭﻝ :2.0ﻣﻠﺨﺺ ﺿﺒﻮﻃﺎﺕ ﺍﻷﺟﻬﺰﺓ ﺍﻻﺧﺘﻴﺎﺭ ﻣﻊ ﻭﺻﻠﺔ ﺍﻟﻌﺒﻮﺭ ﺑﺪﻭﻥ ﻭﺻﻠﺔ ﺍﻟﻌﺒﻮﺭ ﻣﺪﻯ ﺩﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ ﺍﻟﻀﺒﻂ ﻣﺪﻯ ﺩﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ ﺍﻟﻀﺒﻂ ﻣﻦ 20 ﺩﺭﺟﺔ ﻣﺌﻮﻳﺔ 30 -ﺩﺭﺟﺔ ﻣﺌﻮﻳﺔ ﻣﺪﻯ ﺩﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ ﺍﻟﻀﺒﻂ ﻣﻦ 16ﺩﺭﺟﺔ ﻣﺌﻮﻳﺔ 30 -ﺩﺭﺟﺔ ﻣﺌﻮﻳﺔ )ﺍﻻﻓﺘﺮﺍﺿﻲ( ﺗﺮﺑﻮ _ ﻫﺎﺩﺉ ﺇﻳﻘﺎﻑ ﺍﻟﺘﺮﺑﻮ ﻭﺳﺮﻋﺔ ﺍﻟﻤﺮﻭﺣﺔ ﺍﻟﻬﺎﺩﺋﺔ )ﺍﻻﻓﺘﺮﺍﺿﻲ( ﺗﺸﻐﻴﻞ ﺍﻟﺘﺮﺑﻮ ﻭﺳﺮﻋﺔ ﺍﻟﻤﺮﻭﺣﺔ ﺍﻟﻬﺎﺩﺋﺔ * ﻗﺎﺑﻞ ﻟﻠﺘﻄﺒﻴﻖ ﻓﻘﻂ ﻟﻠﻤﻮﺩﻳﻞ ﺍﻟﺬﻱ ﻳﻤﺘﻠﻚ ﻣﻴﺰﺍﺕ ﺍﻟﺘﺮﺑﻮ ﺃﻭ ﺍﻟﻬﺎﺩﺉ ﺍﻟﺪﺍﺧﻠﻴﺔ. 3.0 ﺍﻟﺘﺮﻛﻴﺐ 3.1 ﺍﻟﻤﻠﺤﻘﺎﺕ ﺍﻟﻤﻠﺤﻘﺎﺕ ﺍﻟﺘﺎﻟﻴﺔ ﻣﻮﺟﻮﺩﺓ ﻣﻊ ﻫﺬﺍ ﺍﻟﻜﺘﻴﺐ .ﺍﺫﺍ ﻛﺎﻥ ﺟﺰﺀ ﻣﺎ ﻣﻔﻘﻮﺩ ،ﺍﺗﺼﻞ ﺑﻮﻛﻴﻠﻚ ﻓﻮﺭﺍ ﹰ. .1ﻣﻮﺟﻪ ﺍﻟﺘﺤﻜﻢ ﻋﻦ ﺑﻌﺪ .2ﻣﺴﻤﺎﺭ ﺧﺸﺒﻲ )ﻗﻄﻌﺘﻴﻦ( ﻭﻣﺴﻤﺎﺭ ﺭﺑﻂ ﻣﻠﻮﻟﺐ )ﻗﻄﻌﺘﻴﻦ( .3ﻛﺘﻴﺐ ﺍﻟﺘﻌﻠﻴﻤﺎﺕ .4ﺑﻄﺎﺭﻳﺔ 3.2 ﺍﻟﺪﻟﻴﻞ ﺍﻟﺘﺪﺭﻳﺠﻲ .Iﺍﻓﺘﺢ ﺍﻟﻤﺸﺒﻚ ﺍﻟﻤﻮﺟﻮﺩ ﻓﻲ ﻗﻤﺔ ﻭﺣﺪﺓ ﺍﻟﺘﺤﻜﻢ ﺃﻭﻻ ﻣﺘﺒﻮﻋﺎ ﺑﺎﻟﻤﺸﺒﻚ ﺍﻟﺴﻔﻠﻲ .ﺍﻧﺰﻉ ﻏﻄﺎﺀ ﻭﺣﺪﺓ ﺍﻟﺘﺤﻜﻢ ﺍﻟﻌﻠﻮﻱ ﻣﻦ ﺍﻟﻐﻄﺎﺀ ﺍﻟﺴﻔﻠﻲ. .IIﺛﺒﹼﺖ ﺍﻟﻐﻼﻑ ﺍﻟﺴﻔﻠﻲ ﻋﻠﻰ ﺍﻟﺠﺪﺍﺭ ﺑﻮﺍﺳﻄﺔ ﺍﻟـ 2ﺑﺮﻏﻲ ﺍﻟﻤﺰﻭﺩﺓ .ﺑﻌﺪ ﺫﻟﻚ ﺍﺩﺧﻞ ﺳﻠﻚ ﺍﻟﺘﻮﺻﻴﻞ ﻋﺒﺮ ﺍﻟﺸﻖ ﺍﻟﻤﻮﺟﻮﺩ ﻋﻠﻰ ﺍﻟﻤﺮﻛﺰ ﺍﻟﻌﻠﻮﻱ ﻛﻤﺎ ﻫﻮ ﻣﺒﻴﻦ. .IIIﺍﺩﺧﻞ ﺍﻟﻤﺸﺒﻚ ﺍﻟﺴﻔﻠﻲ ﺃﻭﻻ ﻭﺑﻌﺪ ﺫﻟﻚ ﺃﻃﺒﻖ ﺍﻟﺠﺰﺀ ﺍﻟﻌﻠﻮﻱ ﻟﻺﻏﻼﻕ. ﺍﺳﻼﻙ ﺍﻟﺘﻮﺻﻴﻞ ﻣﻮﺟﻪ ﺍﻟﺘﺤﻜﻢ LCD )ﺍﻟﻐﻄﺎﺀ ﺍﻟﻌﻠﻮﻱ( E MOD TURB O SWIN G QUIE T TIMER TIMER SLEE P OFF ﻣﺴﻤﺎﺭ ﺧﺸﺒﻲ 2 x ﻣﻮﺟﻪ ﺍﻟﺘﺤﻜﻢ LCD )ﺍﻟﻐﻄﺎﺀ ﺍﻟﺴﻔﻠﻲ( ٦ ON / FAN DELA Y TIMER ﺭﻣﺰ ﺍﻟﺨﻄﺄ E3 E4 E5 E6 E7 E8 E9 EA F3 F6 HO H3 H6 H7 H8 H9 J1 J3 J5 J6 J7 J8 J9 L1 L3 L4 L5 L8 L9 LC P1 P4 PJ U0 U2 U4 U7 UA UF UH ﺧﻄﺄ PCBﺍﻟﺨﺎﺭﺟﻲ ﺣﻤﺎﻳﺔ ﻣﻦ ﺍﻟﻀﻐﻂ ﺍﻟﻌﺎﻟﻲ ﺣﻤﺎﻳﺔ ﺍﻟﻀﻐﻂ ﺍﻟﻤﻨﺨﻔﺾ ﻣﺤﺮﻙ ﺍﻟﻀﺎﻏﻄﺔ ﻣﻘﻔﻞ/ﺯﻳﺎﺩﺓ ﺗﺤﻤﻴﻞ ﺍﻟﻀﺎﻏﻄﺔ ﺧﻄﺄ ﺑﺪﺀ ﺗﺸﻐﻴﻞ ﺍﻟﻀﺎﻏﻄﺔ ﻗﻔﻞ ﻣﺤﺮﻙ ﻣﺮﻭﺣﺔ DCﺍﻟﺨﺎﺭﺟﻲ ﺩﺧﻞ ACﺃﻋﻠﻰ ﻣﻦ ﺍﻟﺘﻴﺎﺭ ﺧﻄﺄ EXV ﺧﻄﺄ ﺻﻤﺎﻡ 4ﺍﺗﺠﺎﻫﺎﺕ ﺗﻔﺮﻳﻎ ﺍﻟﺤﺮﺍﺭﺓ ﺍﻟﺰﺍﺋﺪﺓ ﻟﻸﻧﺒﻮﺏ ﺯﻳﺎﺩﺓ ﺗﺴﺨﻴﻦ ﺍﻟﻤﺒﺪﻝ ﺍﻟﺤﺮﺍﺭﻱ ﺧﻄﺄ ﺟﻬﺎﺯ ﻣﺴﺘﺸﻌﺮ ﺍﻟﻀﺎﻏﻄﺔ ﺧﻄﺄ ﻣﻔﺘﺎﺡ ﺍﻟﻀﻐﻂ ﺍﻟﻌﺎﻟﻲ ﺧﻄﺄ ﺍﻛﺘﺸﺎﻑ ﺍﻟﺘﻐﺬﻳﺔ ﺍﻟﺮﺍﺟﻌﺔ ﻟﻠﻀﺎﻏﻄﺔ ﺯﻳﺎﺩﺓ ﺗﺤﻤﻴﻞ ﻣﺤﺮﻙ ﺍﻟﻤﺮﻭﺣﺔ/ﺯﻳﺎﺩﺓ ﺍﻟﺘﻴﺎﺭ/ﺍﻟﻤﺴﺘﺸﻌﺮ ﻏﻴﺮ ﻃﺒﻴﻌﻲ ﺧﻄﺄ ﻣﺘﺤﺴﺲ ﺍﻟﺘﻴﺎﺭ AC ﺍﻟﻤﻘﺎﻭﻡ ﺍﻟﺤﺮﺍﺭﻱ ﻟﻠﻬﻮﺍﺀ ﺍﻟﺨﺎﺭﺟﻲ ﻗﺼﺮ/ﻣﻔﺘﻮﺡ ﺧﻄﺄ ﻣﺴﺘﺸﻌﺮ ﺍﻟﻀﻐﻂ ﺍﻟﻤﻘﺎﻭﻡ ﺍﻟﺤﺮﺍﺭﻱ ﻷﻧﺒﻮﺏ ﺗﺼﺮﻳﻒ ﺍﻟﻀﺎﻏﻄﺔ ﻗﺼﻴﺮ/ﻣﻔﺘﻮﺡ/ﻓﻲ ﻏﻴﺮ ﻣﻜﺎﻧﻪ ﺍﻟﻤﻘﺎﻭﻡ ﺍﻟﺤﺮﺍﺭﻱ ﻷﻧﺒﻮﺏ ﺍﻻﻣﺘﺼﺎﺹ ﻗﺼﺮ/ﻣﻔﺘﻮﺡ ﺍﻟﻤﻘﺎﻭﻡ ﺍﻟﺤﺮﺍﺭﻱ ﻟﻤﺒﺪﻝ ﺍﻟﺤﺮﺍﺭﺓ ﺍﻟﺨﺎﺭﺟﻲ ﻗﺼﻴﺮ/ﻣﻔﺘﻮﺡ ﺍﻟﻤﻘﺎﻭﻡ ﺍﻟﺤﺮﺍﺭﻱ ﻟﻠﻤﺒﺪﻝ ﺍﻟﺤﺮﺍﺭﻱ ﻟﻠﺘﺒﺮﻳﺪ ﺍﻟﺜﺎﻧﻮﻱ ﻗﺼﺮ/ﻣﻔﺘﻮﺡ ﺍﻟﻤﻘﺎﻭﻡ ﺍﻟﺤﺮﺍﺭﻱ ﻷﻧﺒﻮﺏ ﺍﻟﺴﺎﺋﻞ ﻗﺼﺮ/ﻣﻔﺘﻮﺡ ﺍﻟﻤﻘﺎﻭﻡ ﺍﻟﺤﺮﺍﺭﻱ ﻷﻧﺒﻮﺏ ﺍﻟﻐﺎﺯ ﻗﺼﺮ/ﻣﻔﺘﻮﺡ ﺧﻄﺄ PCBﺍﻟﺨﺎﺭﺟﻲ ﻟﻠﻌﺎﻛﺲ ﺯﻳﺎﺩﺓ ﺗﺴﺨﻴﻦ ﺻﻨﺪﻭﻕ ﺍﻟﺘﺤﻜﻢ ﺍﻟﺨﺎﺭﺟﻲ ﺯﻳﺎﺩﺓ ﺗﺴﺨﻴﻦ ﺟﺴﻢ ﺍﻣﺘﺼﺎﺹ ﻭﺗﻔﺮﻳﻖ ﺍﻟﺤﺮﺍﺭﺓ ﺧﻄﺄ /IPMﺧﻄﺄ IGBT ﺯﻳﺎﺩﺓ ﺗﻴﺎﺭ ﺍﻟﻀﺎﻏﻄﺔ ﺍﻟﻌﺎﻛﺴﺔ ﻣﻨﻊ ﺯﻳﺎﺩﺓ ﺗﻴﺎﺭ ﺍﻟﻀﺎﻏﻄﺔ ﺧﻄﺄ ﺍﺗﺼﺎﻝ ) PCBﺍﻟﺘﺤﻜﻢ ﺍﻟﺨﺎﺭﺟﻲ ﻭ PCBﺍﻟﻌﺎﻛﺲ( ﺍﻟﻄﻮﺭ ﻣﻔﺘﻮﺡ ﺍﻭ ﻓﻮﻟﻄﻴﺔ ﻏﻴﺮ ﻣﺘﻌﺎﺩﻟﺔ ﺍﻟﻤﻘﺎﻭﻡ ﺍﻟﺤﺮﺍﺭﻱ ﻟﺠﺴﻢ ﺍﻣﺘﺼﺎﺹ ﻭﺗﻔﺮﻳﻖ ﺍﻟﺤﺮﺍﺭﺓ ﻗﺼﻴﺮ/ﻣﻔﺘﻮﺡ ﺧﻄﺄ ﺿﺒﻂ ﺍﻟﻘﺪﺭﺓ ﺍﻟﻐﺎﺯ ﻏﻴﺮ ﻛﺎﻑ ﻓﻮﻟﻄﻴﺔ DCﺧﺎﺭﺝ ﺍﻟﻤﺪﻯ ﺧﻄﺄ ﺍﺗﺼﺎﻝ ﺧﻄﺄ ﺍﺗﺼﺎﻝ ) PCBﺍﻟﺘﺤﻜﻢ ﺍﻟﺨﺎﺭﺟﻲ ﻭ (IPM PCB ﺧﻄﺄ ﺗﺮﻛﻴﺐ ﻋﺪﻡ ﻣﻼﺋﻤﺔ ﺗﺮﻛﻴﺐ ﺍﻷﻧﺎﺑﻴﺐ ﻭﺍﻷﺳﻼﻙ/ﺃﺳﻼﻙ ﺧﺎﻃﺌﺔ/ﻏﺎﺯ ﻏﻴﺮ ﻛﺎﻑ ﻣﻘﺎﻭﻡ ﺍﻟﺘﺠﻤﺪ )ﺍﻟﻐﺮﻑ ﺍﻷﺧﺮﻯ( ٥ ﺍﻟﻌﺮﺑﻴﺔ E1 ﺍﻟﻤﻌﻨﻰ 1.14 ﺍﻟﺒﻄﺎﺭﻳﺔ ﺍﻻﺣﺘﻴﺎﻃﻴﺔ ﺗﺴﺘﻌﻤﻞ ﺑﻄﺎﺭﻳﺔ ﺍﻟﺪﻋﻢ ﻟﺤﻔﻆ ﺳﺎﻋﺔ ﺍﻟﻮﻗﺖ ﺍﻟﺤﻘﻴﻘﻲ RTCﻭ ﺿﺒﻮﻃﺎﺕ ﺍﻟﻤﺆﻗﺖ ﺍﻟﻘﺎﺑﻠﺔ ﻟﻠﺒﺮﻣﺠﺔ ﻟﻤﺪﺓ - 7ﺃﻳﺎﻡ ﺃﺛﻨﺎﺀ ﺣﺼﻮﻝ ﻋﻄﻞ ﺍﻟﻄﺎﻗﺔ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﻟﻤﺪﺓ 1ﺷﻬﺮ ﻣﺘﻮﺍﺻﻞ ﻋﻠﻰ ﺍﻷﻗﻞ ﻟﻜﻞ ﻣﺠﻤﻮﻋﺔ ﺟﺪﻳﺪﺓ ﻣﻦ ﺍﻟﺒﻄﺎﺭﻳﺔ ﺗﻢ ﺗﺮﻛﻴﺒﻬﺎ. ﻟﻠﻮﺣﺪﺓ ﺍﻟﺘﻲ ﻻ ﺗﺤﺘﻮﻱ ﻋﻠﻰ ﺑﻄﺎﺭﻳﺔ ﺩﻋﻢ ،ﺳﻮﻑ ﻳﻜﻮﻥ ﺍﻟﻀﺒﻂ ﺍﻷﺻﻠﻲ 12:00ﺻﺒﺎﺣﺎ ﻣﻦ ﻳﻮﻡ ﺍﻻﺛﻨﻴﻦ ﻭﺇﻟﻐﺎﺀ ﺍﻟﻤﺆﻗﺖ ﻋﻨﺪ ﺑﺪﺀ ﺍﻟﺘﺸﻐﻴﻞ. 1.15 ﻣﺆﺷﺮ ﺍﻟﺨﻄﺄ ﺇﺫﺍ ﺗﻢ ﺍﻛﺘﺸﺎﻑ ﺣﺎﻟﺔ ﻏﻴﺮ ﻃﺒﻴﻌﻴﺔ ،ﺳﻮﻑ ﻳﻈﻬﺮ ﻛﻮﺩ ﺍﻟﺨﻄﺄ .ﻳﺘﻢ ﻋﺮﺽ ﻛﻮﺩ ﺍﻟﺨﻄﺄ ﺑﻮﺍﺳﻄﺔ ﺍﺳﺘﻌﻤﺎﻝ ﺃﻗﺴﺎﻡ ) RTCﻭﻣﺾ(، ﻭﻫﺬﺍ ﻳﻌﻨﻲ ﻋﻨﺪﻣﺎ ﻳﺤﺼﻞ ﺧﻄﺄ ،ﺳﻮﻑ ﻻ ﻳﺘﻢ ﻋﺮﺽ RTCﺑﺪﻻ ﻣﻦ ﻛﻮﺩ ﺍﻟﺨﻄﺄ .ﺳﻮﻑ ﻳﻜﻮﻥ ﺷﻜﻞ ﻛﻮﺩ ﺍﻟﺨﻄﺄ ﻛﻤﺎ ﻳﻠﻲ: ﻛﻮﺩ ﺍﻟﺨﻄﺄ DX ﻭﺻﻒ ﺍﻟﺨﻄﺄ ﻣﺘﺤﺴﺲ ﺍﻟﻐﺮﻓﺔ ﻣﻔﺘﻮﺡ ﺃﻭ ﻗﺼﻴﺮ ﻣﺘﺤﺴﺲ ﻣﻠﻒ ﺍﻟﺪﺍﺧﻞ ﻣﻔﺘﻮﺡ ﻣﺘﺤﺴﺲ ﻣﻠﻒ ﺍﻟﺨﺎﺭﺝ ﻣﻔﺘﻮﺡ ﺯﻳﺎﺩﺓ ﺣﻤﻞ ﺍﻟﻀﺎﻏﻄﺔ/ﻣﺘﺤﺴﺲ ﻣﻠﻒ ﺍﻟﺪﺍﺧﻞ ﻗﺼﻴﺮ/ﻣﺘﺤﺴﺲ ﻣﻠﻒ ﺍﻟﺨﺎﺭﺝ ﻗﺼﻴﺮ ﺍﻧﺨﻔﺎﺽ ﺍﻟﻤﺒﺮﺩﺍﺕ ﺗﻬﻤﺔ/ﺗﺴﺮﺏ ﺍﻟﻐﺎﺯ/ﻓﻲ ﺍﻟﻬﻮﺍﺀ ﺍﻟﻄﻠﻖ ﻏﻴﺮ ﻃﺒﻴﻌﻲ ﺧﻄﺄ ﻓﻲ ﻣﻀﺨﺔ ﺍﻟﻤﺎﺀ ﻭﺟﻮﺩ ﻣﺘﺤﺴﺲ ﻣﻠﻒ ﺍﻟﺨﺎﺭﺝ )ﻭﺿﻊ (MS ﺧﻄﺄ ﺃﺟﻬﺰﺓ )ﺩﺑﻮﺱ ﻣﻔﺘﺎﺡ ﺍﻟﺤﺴﺎﺳﻴﺔ ﻗﺼﻴﺮ( ﺧﻄﺄ ﺗﻐﺬﻳﺔ ﺍﺭﺗﺪﺍﺩﻳﺔ ﻓﻲ ﺍﻟﻤﺮﻭﺣﺔ ﺍﻟﺪﺍﺧﻠﻴﺔ E9 ﺧﻄﺎﺀ EEPROM EE E1 E2 E3 E4 E5 E6 E7 E8 ﻛﻮﺩ ﺍﻟﺨﻄﺄ CW ﻭﺻﻒ ﺍﻟﺨﻄﺄ ﻣﺘﺤﺴﺲ ﺍﻟﻐﺮﻓﺔ ﻣﻔﺘﻮﺡ ﺃﻭ ﻗﺼﻴﺮ ﻣﺘﺤﺴﺲ ﻣﺎﺀ ﺍﻷﻧﺒﻮﺏ ﻣﻔﺘﻮﺡ ﺃﻭ ﻗﺼﻴﺮ ﺩﺭﺟﺔ ﺣﺮﺍﺭﺓ ﻣﺎﺀ ﺍﻷﻧﺒﻮﺏ ﺿﻌﻴﻔﺔ ﺩﺭﺟﺔ ﺣﺮﺍﺭﺓ ﻣﺎﺀ ﺍﻷﻧﺒﻮﺏ ﺭﺩﻳﺌﺔ/ﺧﺎﻃﺌﺔ ﺧﻄﺄ ﻓﻲ ﻣﻀﺨﺔ ﺍﻟﻤﺎﺀ ﺧﻄﺄ ﺃﺟﻬﺰﺓ )ﺩﺑﻮﺱ ﻣﻔﺘﺎﺡ ﺍﻟﺤﺴﺎﺳﻴﺔ ﻗﺼﻴﺮ( ﺧﻄﺄ ﺗﻐﺬﻳﺔ ﺍﺭﺗﺪﺍﺩﻳﺔ ﻓﻲ ﺍﻟﻤﺮﻭﺣﺔ ﺍﻟﺪﺍﺧﻠﻴﺔ E1 E2 E4 E5 E6 E8 E9 ﺗﺸﺨﻴﺺ ﺍﻷﻋﻄﺎﻝ )ﻓﻘﻂ ﻟﻠﻌﺎﻛﺲ( ﺇﺫﺍ ﺗﻢ ﺍﻛﺘﺸﺎﻑ ﺣﺎﻟﺔ ﻏﻴﺮ ﻃﺒﻴﻌﻴﺔ ،ﺳﻮﻑ ﺗﻮﻣﺾ ﻭﺣﺪﺓ ﺍﻟﺘﺤﻜﻢ ﺍﻟﺴﻠﻜﻴﺔ SLM9ﻛﻮﺩ ﺍﻟﺨﻄﺄ ﺭﻣﺰ ﺍﻟﺨﻄﺄ 00 A1 A3 A5 A6 AH C4 C5 C7 C9 ﺍﻟﻤﻌﻨﻰ ﻋﺎﺩﻱ ﺧﻄﺄ PCBﺩﺍﺧﻠﻲ ﻣﻀﺨﺔ ﺍﻟﺘﺼﺮﻳﻒ ﻏﻴﺮ ﻃﺒﻴﻌﻴﺔ ﻣﻘﺎﻭﻡ ﺍﻟﺘﺠﻤﺪ )ﺍﻟﺘﺒﺮﻳﺪ(/ﺯﻳﺎﺩﺓ ﺗﺴﺨﻴﻦ ﺍﻟﻤﺒﺪﻝ ﺍﻟﺤﺮﺍﺭﻱ )ﺍﻟﺘﺪﻓﺌﺔ( ﻣﺤﺮﻙ ﺍﻟﻤﺮﻭﺣﺔ ﺍﻟﺪﺍﺧﻠﻲ ﻏﻴﺮ ﻃﺒﻴﻌﻲ ﻣﻨﻈﻒ ﺍﻟﻬﻮﺍﺀ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ ﻏﻴﺮ ﻃﺒﻴﻌﻲ ﹺ ﻟﻤﺒﺪﻝ ﺍﻟﺤﺮﺍﺭ ﹺﺓ ﺍﻟﺪﺍﺧﻠﻲ ﻗﺼﻴﺮ )/ (1ﻣﻔﺘﻮﺡ ﺍﻟﻤﻘﺎﻭﻡ ﺍﻟﺤﺮﺍﺭﻱ ﹼ ﹺ ﻟﻤﺒﺪﻝ ﺍﻟﺤﺮﺍﺭ ﹺﺓ ﺍﻟﺪﺍﺧﻠﻲ ﻗﺼﻴﺮ )/ (2ﻣﻔﺘﻮﺡ ﺍﻟﻤﻘﺎﻭﻡ ﺍﻟﺤﺮﺍﺭﻱ ﹼ ﺧﻄﺄ ﻣﻔﺘﺎﺡ ﺗﺤﺪﻳﺪ ﺷﻖ ﺍﻟﺘﻬﻮﻳﺔ ﹺ ﺍﻟﺪﺍﺧﻠﻲ ﻗﺼﻴﺮ/ﻣﻔﺘﻮﺡ ﺍﻟﻤﻘﺎﻭﻡ ﺍﻟﺤﺮﺍﺭﻱ ﻟﻠﻐﺮﻓﺔ ٤ 1.9 ﻭﻇﻴﻔﺔ ﺳﺮﻋﺔ ﺍﻟﻤﺮﻭﺣﺔ FAN ﻳﻤﻜﻦ ﺗﻐﻴﻴﺮ ﺳﺮﻋﺔ ﺍﻟﻤﺮﻭﺣﺔ ﺑﻮﺍﺳﻄﺔ ﺿﻐﻂ ﻣﻔﺘﺎﺡ ﺍﻟﻤﺮﻭﺣﺔ: ﻣﻨﺨﻔﺾ < ﻣﺘﻮﺳﻂ < ﻋﺎﻟﻲ < ﺗﻠﻘﺎﺋﻲ < *ﺳﺮﻋﺔ ﺍﻟﻤﺮﻭﺣﺔ FANﻏﻴﺮ ﻣﺘﻮﻓﺮﺓ ﻓﻲ ﻭﺿﻊ ﺍﻟﺘﺠﻔﻴﻒ .DRY 1.10 ﺯﺭ ON/OFF ﺑﺪﺀ ﺍﻟﺘﺸﻐﻴﻞ: – ﺍﺿﻐﻂ ﺍﻟﺰﺭ ،ON/OFFﻋﻨﺪ ﺫﻟﻚ ﺳﻮﻑ ﺗﺒﻴﻦ ﺷﺎﺷﺔ LCDﻋﺮﺽ ﻛﺎﻣﻞ ﻭ ﺗﺸﺘﻐﻞ ﺍﻟﻮﺣﺪﺓ. ﺍﻳﻘﺎﻑ ﺍﻟﺘﺸﻐﻴﻞ: – ﺍﺿﻐﻂ ﺍﻟﺰﺭ ،ON/OFFﻋﻨﺪ ﺫﻟﻚ ﺳﻮﻑ ﺗﺒﻴﻦ ﺷﺎﺷﺔ LCDﺳﺎﻋﺔ ﺍﻟﻮﻗﺖ ﺍﻟﺤﻘﻴﻘﻲ ﻭ ﺗﺘﻮﻗﻒ ﺍﻟﻮﺣﺪﺓ. 1.11 ﺍﻟﺘﺸﻐﻴﻞ ﻋﻠﻰ ﺍﻟﻀﺒﻮﻃﺎﺕ ﺍﻟﺴﺎﺑﻘﺔ ﺳﻮﻑ ﺗﺸﺘﻐﻞ ﺍﻟﻮﺣﺪﺓ ﻋﻠﻰ ﺣﺎﻟﺔ ﺁﺧﺮ ﺿﺒﻮﻃﺎﺕ ﺳﺎﺑﻘﺔ ﻋﻨﺪ ﺑﺪﺀ ﺗﺸﻐﻴﻞ ﺍﻟﻮﺣﺪﺓ .ﺇﺫﺍ ﻛﺎﻧﺖ ﻣﻌﻠﻮﻣﺎﺕ ﺍﻟﺤﺎﻟﺔ ﺍﻷﺧﻴﺮﺓ ﻏﻴﺮ ﻣﺘﻮﻓﺮﺓ ،ﺳﻮﻑ ﺗﺴﺘﻌﻤﻞ ﺍﻟﻮﺣﺪﺓ ﺍﻟﻀﺒﻮﻃﺎﺕ ﺍﻷﺻﻠﻴﺔ .ﺍﻟﻀﺒﻮﻃﺎﺕ ﺍﻷﺻﻠﻴﺔ ﻛﻤﺎ ﻓﻲ ﺍﻷﺳﻔﻞ: :Unit :Mode :Fan Speed :RTC ﺍﻟﺘﺄﺭﺟﺢ: ﻭﺿﻊ ﺍﻟﺘﺄﺭﺟﺢ: ﺍﳌﺆﻗﺘﺎﺕ: Off Cool ﻋﺎﻟﻲ 12:00ﺻﺒﺎﺣﺎ ،ﺍﻻﺛﻨﲔ Off ﻗﻴﺎﺳﻲ ﻣﻌﻄﻠﺔ ﻣﻌﻄﻠﺔ :Turbo :Quiet :Sleep Off Off ﺍﻟﺘﺠﺎﻭﺯ: ﻣﻌﻄﻠﺔ 1.12 ﻋﺮﺽ ﺳﺎﻋﺔ ﺍﻟﻮﻗﺖ -ﺍﻟﺤﻘﻴﻘﻲ )(RTC ﺗﻈﻬﺮ ﺍﻹﺷﺎﺭﺓ RTCﻋﻠﻰ ﺍﻟﺸﺎﺷﺔ ﺃﺛﻨﺎﺀ ﺗﺸﻐﻴﻞ ONﺃﻭ ﺇﻳﻘﺎﻑ OFFﺗﺸﻐﻴﻞ ﺍﻟﻮﺣﺪﺓ ﺑﺎﺳﺘﺜﻨﺎﺀ ﻋﻨﺪ ﺣﺼﻮﻝ ﻋﻄﻞ ﻓﻲ ﺍﻟﻄﺎﻗﺔ ﺃﻭ ﻛﻮﺩ ﺍﻟﺨﻄﺄ. ﺇﻋﺪﺍﺩ ﺿﺒﻂ RTC .1ﺍﺿﻐﻂ RTCﻣﻔﺘﺎﺡ ﻣﺮﺓ ﻭﺍﺣﺪﺓ ﺗﻨﺸﻴﻂ RTCﻭﺿﻊ ﺍﻹﻋﺪﺍﺩ) .ﺳﻮﻑ ﻳﻮﻣﺾ ﺍﻟﻴﻮﻡ( .2ﺍﺿﻐﻂ UPﺃﻭ DOWNﻻﺧﺘﻴﺎﺭ ﺍﻟﻴﻮﻡ. .3ﺍﺿﻐﻂ RTCﻣﺮﺓ ﺛﺎﻧﻴﺔ ﻟﺘﺄﻛﻴﺪ ﺍﻟﻴﻮﻡ) .ﺑﻌﺪ ﺫﻟﻚ ﺳﻮﻑ ﺗﻮﻣﺾ ﺍﻟﺴﺎﻋﺔ( .4ﺍﺿﻐﻂ UPﺃﻭ DOWNﻟﺘﻐﻴﻴ ﹲﺮ ﺍﻟﺴﺎﻋﺔ. .5ﺍﺿﻐﻂ RTCﻣﺮﺓ ﺛﺎﻧﻴﺔ ﻟﺘﺄﻛﻴﺪ ﺍﻟﺴﺎﻋﺔ) .ﺑﻌﺪ ﺫﻟﻚ ﺳﻮﻑ ﺗﻮﻣﺾ ﺍﻟﺪﻗﻴﻘﺔ( .6ﺍﺿﻐﻂ UPﺃﻭ DOWNﻟﺘﻐﻴﻴﺮ ﺍﻟﺪﻗﻴﻘﺔ. .7ﺍﺿﻐﻂ RTCﻣﺮﺓ ﺛﺎﻧﻴﺔ ﻟﺘﺄﻛﻴﺪ ﺍﻟﺪﻗﻴﻘﺔ. ﺳﻮﻑ ﻳﺘﻢ ﺿﺒﻂ RTCﻓﻘﻂ ﺑﻌﺪ ﻛﻞ ﺍﻟﺨﻄﻮﺍﺕ ﺍﻟـ ،7ﻭﻓﻲ ﺣﺎﻟﺔ ﻋﺪﻡ ﻋﻤﻞ ﻋﻤﻠﻴﺔ ﺗﺸﻐﻴﻞ ﻟﻠﻤﻔﺘﺎﺡ ﻟﻤﺪﺓ 5ﺛﻮﺍﻥ ﺃﺛﻨﺎﺀ ﺿﺒﻂ ،RTCﺳﻮﻑ ﻳﺘﻢ ﺍﻟﺨﺮﻭﺝ ﻣﻦ ﻭﺿﻊ ﺍﻟﻀﺒﻂ ﺃﻭﺗﻮﻣﺎﺗﻴﻜﻴﺎ ﻭﺳﻮﻑ ﻻ ﻳﺘﻢ ﻋﻤﻞ ﺗﻐﻴﻴﺮﺍﺕ. 1.13 ﻗﻔﻞ ﺍﻟﻤﻔﺘﺎﺡ ﺗﻤﻨﻊ ﻭﻇﻴﻔﺔ ﻗﻔﻞ ﺍﻟﻤﻔﺘﺎﺡ ﺃﻱ ﺗﻐﻴﻴﺮ ﻟﻠﻀﺒﻂ.ﺍﺿﻐﻂ ﻭﺗﺎﺑﻊ ﺿﻐﻂ ﻛﻼ ﻣﻦ ﻣﻔﺘﺎﺡ ﺍﻟﺘﺮﺑﻮ TURBOﻭ ﺍﻟﻬﺎﺩﺉ QUIETﻟﻤﺪﺓ 5 ﺛﻮﺍﻥ ﻭﺑﻌﺪ ﺫﻟﻚ ﺳﻮﻑ ﻳﺘﻢ ﺗﺸﻐﻴﻞ/ﺍﻳﻘﺎﻑ ﻭﻇﻴﻔﺔ ﻗﻔﻞ ﺍﻟﻤﻔﺘﺎﺡ؛ ﺳﻮﻑ ﺗﻈﻬﺮ/ﺗﺨﺘﻔﻲ ﺍﻹﺷﺎﺭﺓ ” “KEYLOCKﻋﻠﻰ ﺷﺎﺷﺔ .LCDﻋﻨﺪﻣﺎ ﻳﺘﻢ ﻗﻔﻞ ﻛﻞ ﺍﻟﻤﻔﺎﺗﻴﺢ ،ﻓﺎﻧﻪ ﻳﻤﻜﻦ ﻓﻘﻂ ﺿﻐﻂ ﺍﻟﻤﻔﺎﺗﻴﺢ TURBO، ON/OFFﻭ ) QUIETﻟﻔﻚ ﺍﻟﻘﻔﻞ(. ٣ ﺍﻟﻌﺮﺑﻴﺔ 1.8 ﻭﻇﻴﻔﺔ ﻣﺆﻗﺖ ﺍﻟﺘﺄﺧﻴﺮ DELAY TIMER ﺿﻐﻂ ﻣﻔﺘﺎﺡ DELAY TIMERﻣﺮﺓ ﻭﺍﺣﺪﺓ ﺳﻮﻑ ﻳﻨﺸﻂ ﻭﻇﻴﻔﺔ ﻣﺆﻗﺖ ﺍﻟﺘﺄﺧﻴﺮ ﻟﻤﺪﺓ 1ﺳﺎﻋﺔ .ﺳﻮﻑ ﺗﻈﻬﺮ ﺍﻹﺷﺎﺭﺓ ” “OVERRIDEﻋﻠﻰ ﺷﺎﺷﺔ .LCDﺿﻐﻂ ﻧﻔﺲ ﺍﻟﻤﻔﺘﺎﺡ ﻣﺮﺓ ﺛﺎﻧﻴﺔ ﺳﻮﻑ ﻳﺰﻳﺪ ﺍﻟﻀﺒﻂ ﺇﻟﻰ 2ﺳﺎﻋﺔ .ﺳﻮﻑ ﺗﻈﻬﺮ ﺇﺷﺎﺭﺓ ” .“OVERRIDEﺍﻟﻀﻐﻄﺔ ﺍﻟﺘﺎﻟﻴﺔ ﺳﻮﻑ ﺗﻮﻗﻒ ﺗﺸﻐﻴﻞ ﻭﻇﻴﻔﺔ ﻣﺆﻗﺖ ﺍﻟﺘﺄﺧﻴﺮ .ﺑﻌﺪ ﺍﻛﺘﻤﺎﻝ ﻣﺆﻗﹼﺖ ﺍﻟﺘﺄﺧﻴﺮ ،ﻳﺘﻢ ﺇﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﻭﻇﻴﻔﺔ ﻣﺆﻗﺖ ﺍﻟﺘﺄﺧﻴﺮ ﻭﺗﻜﻮﻥ ﺍﻹﺷﺎﺭﺓ ﺇﻳﻘﺎﻑ .OFFﺳﻮﻑ ﻳﺘﻢ ﺍﺳﺘﺌﻨﺎﻑ ﻛﻞ ﺍﻟﻤﺆﻗﺘﺎﺕ ﺍﻻﺧﺮﻯ. ﺍﻟﺠﺪﻭﻝ .1.1 :ﺗﺴﻠﺴﻞ ﺿﻐﻂ ﻭﺍﻟﺤﺪﺙ ﻟﻤﻔﺘﺎﺡ ﻣﺆﻗﺖ ﺍﻟﺘﺸﻐﻴﻞ ONﻭﻣﺆﻗﺖ ﺍﻹﻳﻘﺎﻑ .OFF ﻣﻔﺘﺎﺡ ﻣﺆﻗﺖ ﺍﻹﻳﻘﺎﻑ TIMER OFF ﻣﻔﺘﺎﺡ ﻣﺆﻗﺖ ﺍﻟﺘﺸﻐﻴﻞ TIMER ON ﻣﺆﻗﺖ ﺍﻟﺘﺸﻐﻴﻞ ON 1 ﻣﺆﻗﺖ ﺍﻟﺘﺸﻐﻴﻞ ON 2 ﻣﺆﻗﺖ ﺍﻹﻳﻘﺎﻑ OFF 1 ﻣﺆﻗﺖ ﺍﻹﻳﻘﺎﻑ OFF 2 ﺍﻳﻘﺎﻑ ﺍﻳﻘﺎﻑ ﺍﻳﻘﺎﻑ ﺍﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﺍﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﺍﻳﻘﺎﻑ ﺍﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﺍﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﺗﺸﻐﻴﻞ ﺗﺸﻐﻴﻞ ﺗﺸﻐﻴﻞ ﺗﺸﻐﻴﻞ ﺟﻤﻴﻊ ﺍﻟﻤﺆﻗﺘﺎﺕ ﻫﻲ ﻣﺆﻗﺘﺎﺕ ﻣﻨﺒﻬﺔ ﻭﻳﻤﻜﻦ ﺍﻳﻘﺎﻓﻬﺎ ﺑﻮﺍﺳﻄﺔ ﺍﻟﺰﺭ ON / OFFﻭﻭﻇﻴﻔﺔ ﺍﻻﻳﻘﺎﻑ. ﺍﺿﺒﻂ ﺍﳌﺆﻗﺘﺎﺕ ﻟﻠﻮﺿﻊ 1ﻭ 2ﻓﻲ ﻭﺿﻊ ﺗﻬﻴﺌﺔ ﺍﳌﺆﻗﺖ ﺍﻟﻌﻤﻠﻴﺔ ﻟﻤﺆﻗﺖ ﺍﻟﺘﺸﻐﻴﻞ ONﻭﻣﺆﻗﺖ ﺍﻹﻳﻘﺎﻑ OFFﻫﻲ ﻧﻔﺴﻬﺎ. .1ﺍﺿﻐﻂ ﻭﺗﺎﺑﻊ ﺿﻐﻂ ﻣﻔﺘﺎﺡ ﺍﻟﻤﺆﻗﺖ ON/OFFﻟﻤﺪﺓ 3ﺛﻮﺍﻥ ﻟﻠﺬﻫﺎﺏ ﺇﻟﻰ ﻭﺿﻊ ﺿﺒﻂ ﺍﻟﻤﺆﻗﺖ. )ﺳﻮﻑ ﺗﻮﻣﺾ ﺍﻹﺷﺎﺭﺓ ON 1ﺃﻭ (OFF 1 .2ﺍﺿﻐﻂ UPﺃﻭ DOWNﻻﺧﺘﻴﺎﺭ ﻣﺆﻗﺖ 1ﺃﻭ ﻣﺆﻗﺖ 2ﻟﻠﻀﺒﻂ. )ﻳﺸﻴﺮ ﻭﻣﺾ ﺍﻟﺮﻗﻢ ’ ‘1ﺇﻟﻰ ﺃﻥ ﺍﻟﻤﺆﻗﺖ 1ﻣﺨﺘﺎﺭ ﺣﺎﻟﻴﺎ ،ﻭﻳﺸﻴﺮ ﻭﻣﺾ ﺍﻟﺮﻗﻢ ’ ‘2ﺇﻟﻰ ﺃﻥ ﺍﻟﻤﺆﻗﺖ 2ﻣﺨﺘﺎﺭ ﺣﺎﻟﻴﺎ( .3ﺍﺿﻐﻂ ﻣﻔﺘﺎﺡ ﺍﻟﻤﺆﻗﺖ ON/OFFﻣﺮﺓ ﺛﺎﻧﻴﺔ ﻟﻠﺘﺄﻛﻴﺪ) .ﺑﻌﺪ ﺫﻟﻚ ﺳﻮﻑ ﻳﻮﻣﺾ ﺍﻟﻴﻮﻡ( .4ﺍﺿﻐﻂ UPﺃﻭ DOWNﻻﺧﺘﻴﺎﺭ ﺍﻟﻴﻮﻡ. .5ﺍﺿﻐﻂ ﻣﻔﺘﺎﺡ ﺍﻟﻤﺆﻗﺖ ON/OFFﻟﺘﺄﻛﻴﺪ ﺍﻟﻴﻮﻡ) .ﺑﻌﺪ ﺫﻟﻚ ﺳﻮﻑ ﺗﻮﻣﺾ ﺍﻟﺴﺎﻋﺔ( .6ﺍﺿﻐﻂ UPﺃﻭ DOWNﻟﺘﻐﻴﻴﺮ ﺍﻟﺴﺎﻋﺔ. .7ﺍﺿﻐﻂ ﻣﻔﺘﺎﺡ ﺍﻟﻤﺆﻗﺖ ON/OFFﻣﺮﺓ ﺛﺎﻧﻴﺔ ﻟﺘﺄﻛﻴﺪ ﺍﻟﺴﺎﻋﺔ) .ﺑﻌﺪ ﺫﻟﻚ ﺳﻮﻑ ﺗﻮﻣﺾ ﺍﻟﺪﻗﻴﻘﺔ( .8ﺍﺿﻐﻂ UPﺃﻭ DOWNﻟﺘﻐﻴﻴﺮ ﺍﻟﺪﻗﻴﻘﺔ. .9ﺍﺿﻐﻂ ﻣﻔﺘﺎﺡ ﺍﻟﻤﺆﻗﺖ ON/OFFﻣﺮﺓ ﺛﺎﻧﻴﺔ ﻟﺘﺄﻛﻴﺪ ﺍﻟﺪﻗﻴﻘﺔ. ﺳﻮﻑ ﻳﺘﻢ ﺿﺒﻂ ﻛﻞ ﻣﺆﻗﺖ )ﻣﺆﻗﺖ ﺍﻟﺘﺸﻐﻴﻞ 1 ONﺃﻭ ﻣﺆﻗﺖ ﺍﻹﻳﻘﺎﻑ 1 OFFﺃﻭ ﻣﺆﻗﺖ ﺍﻟﺘﺸﻐﻴﻞ 2 ONﺃﻭ ﻣﺆﻗﺖ ﺍﻹﻳﻘﺎﻑ (2 OFFﺑﺸﻜﻞ ﻣﻨﻔﺼﻞ ﺑﻌﺪ ﻛﻞ ﺍﻟﺨﻄﻮﺍﺕ ﺍﻟـ ،7ﻭﻓﻲ ﺣﺎﻟﺔ ﻋﺪﻡ ﻋﻤﻞ ﻋﻤﻠﻴﺔ ﺗﺸﻐﻴﻞ ﻟﻠﻤﻔﺘﺎﺡ ﻟﻤﺪﺓ 5ﺛﻮﺍﻥ ﺃﺛﻨﺎﺀ ﺿﺒﻂ ﺍﻟﻤﺆﻗﺖ ،ﺳﻮﻑ ﻳﺘﻢ ﺍﻟﺨﺮﻭﺝ ﻣﻦ ﻭﺿﻊ ﺍﻟﻀﺒﻂ ﺃﻭﺗﻮﻣﺎﺗﻴﻜﻴﺎ ﻭﺳﻮﻑ ﻻ ﻳﺘﻢ ﻋﻤﻞ ﺗﻐﻴﻴﺮﺍﺕ. ﺳﻮﻑ ﺑﺘﻢ ﻓﺤﺺ ﻣﺆﻗﺖ ON/OFFﻛﻞ 1ﺩﻗﻴﻘﺔ. ﻟﻴﺲ ﻣﻦ ﺍﻟﻤﺴﺘﺤﺴﻦ ﺃﻥ ﻳﻤﺘﻠﻚ ﺿﺒﻂ ﻣﺆﻗﺖ ﺍﻟﺘﺸﻐﻴﻞ ON TIMERﻭﻣﺆﻗﺖ ﺍﻹﻳﻘﺎﻑ OFF TIMERﻧﻔﺲ ﺍﻟﻘﻴﻢ .ﺇﺫﺍ ﻛﺎﻧﺖ ﺍﻟﻘﻴﻢ ﻣﺘﺴﺎﻭﻳﺔ ،ﺳﻮﻑ ﻳﺘﻢ ﻣﻌﺎﻣﻠﺔ ﺍﻟﻤﺆ ﹼﻗﺖ ﺍﻟﻔﻌﺎﻝ ﺑﺎﻷﻭﻟﻮﻳﺔ ﻛﻤﺎ ﻫﻮ ﻣﺒﻴﻦ ﻓﻲ ﺍﻟﺠﺪﻭﻝ .1.2 ﻣﺜﺎﻝ: ﺿﺒﻮﻃﺎﺕ ﻣﺆﻗﺖ ﺍﻟﺘﺸﻐﻴﻞ DAY – TUE, TIMER – 5.00pm : ON TMR 2: ﺿﺒﻮﻃﺎﺕ ﻣﺆﻗﺖ ﺍﻹﻳﻘﺎﻑ DAY – TUE, TIMER – 5.00pm : OFF TMR 1: ﺍﻟﻨﺘﻴﺠﺔ ﻋﻨﺪﻣﺎ ﺗﺼﻞ ﺳﺎﻋﺔ ﺍﻟﺘﻮﻗﻴﺖ ﺍﻟﺤﻘﻴﻘﻲ RTCﺇﻟﻰ ﺍﻟﺴﺎﻋﺔ 5.00ﺑﻌﺪ ﺍﻟﻈﻬﺮ ﻣﻦ ﻳﻮﻡ ﺍﻟﺜﻼﺛﺎﺀ: – ﻋﻨﺪﻣﺎ ﺗﻜﻮﻥ ﺍﻟﻮﺣﺪﺓ ﻓﻲ ﺣﺎﻟﺔ ﺗﺸﻐﻴﻞ ،ﻻ ﻳﻮﺟﺪ ﺍﺳﺘﺠﺎﺑﺔ. – ﻋﻨﺪﻣﺎ ﺗﻜﻮﻥ ﺍﻟﻮﺣﺪﺓ ﻓﻲ ﺣﺎﻟﺔ ﺇﻳﻘﺎﻑ ،ﺳﻮﻑ ﺗﺬﻫﺐ ﺍﻟﻮﺣﺪﺓ ﺇﻟﻰ ﻭﺿﻊ ﺍﻟﺘﺸﻐﻴﻞ. ﺍﻟﺠﺪﻭﻝ :1.2ﺃﻭﻟﻮﻳﺔ ﺍﻟﻤﺆﻗﺖ ﺍﻷﻭﻟﻮﻳﺔ Timer ) 1ﺍﻷﻋﻠﻰ( ONTMR2 2 OFFTMR2 3 ONTMR1 ) 4ﺍﻷﺩﻧﻰ( OFFTMR1 ﻋﻨﺪ ﺍﺳﺘﻘﺒﺎﻝ ،IRﺳﻮﻑ ﺗﺘﺠﺎﻭﺯ ﻭﺣﺪﺓ ﺍﻟﺘﺤﻜﻢ ﻋﻦ ﺑﻌﺪ ﺍﻟﻼﺳﻠﻜﻴﺔ IRﺿﺒﻮﻃﺎﺕ ﻣﺆﻗﺖ ﺍﻟﺘﺸﻐﻴﻞ ON TIMER 2ﻭ ﻣﺆﻗﺖ ﺍﻹﻳﻘﺎﻑ .ON TIMER 2 ٢ 1.2 ﺳﺮﻋﺔ ﻣﺮﻭﺣﺔ ﺍﻟﺘﺮﺑﻮ TURBO ﺍﺿﻐﻂ ﻣﻔﺘﺎﺡ ﺳﺮﻋﺔ ﻣﺮﻭﺣﺔ ﺍﻟﺘﺮﺑﻮ TURBOﻣﺮﺓ ﻭﺍﺣﺪﺓ ﻟﺘﻨﺸﻴﻂ ﺳﺮﻋﺔ ﻣﺮﻭﺣﺔ ﺍﻟﺘﺮﺑﻮ .ﺳﻮﻑ ﻳﻈﻬﺮ ﺭﻣﺰ ﺍﻟﺘﺮﺑﻮ. ﻹﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﺳﺮﻋﺔ ﻣﺮﻭﺣﺔ ﺍﻟﺘﺮﺑﻮ ﻭﺍﻟﺮﺟﻮﻉ ﺇﻟﻰ ﺳﺮﻋﺔ ﺍﻟﻤﺮﻭﺣﺔ ﺍﻟﺴﺎﺑﻘﺔ ،ﺍﺿﻐﻂ ﻣﻔﺘﺎﺡ ﺍﻟﺘﺮﺑﻮ ﻣﺮﺓ ﺛﺎﻧﻴﺔ .ﺇﺫﺍ ﺿﻐﻂ ﺍﻟﻤﺴﺘﺨﺪﻡ ﺯﺭ ﺍﻟﻤﺮﻭﺣﺔ FANﺃﻭ ﺯﺭ ﺍﻟﻬﺎﺩﺉ QUIETﺃﻭ ﺃﻭﻗﻒ ﺗﺸﻐﻴﻞ ﺍﻟﻮﺣﺪﺓ ،ﺳﻮﻑ ﻳﺘﻢ ﺇﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﺳﺮﻋﺔ ﺍﻟﺘﺮﺑﻮ. ﻫﺬﻩ ﺍﻟﺴﺮﻋﺔ ﻓﻌﺎﻟﺔ ﻓﻘﻂ ﺃﺛﻨﺎﺀ ﻭﺿﻊ ﺍﻟﺘﺒﺮﻳﺪ COOLﻭﺍﻟﺘﺪﻓﺌﺔ HEATﻟﻠﻤﻮﺩﻳﻠﺎﺕ ﺍﻟﻤﺨﺘﺎﺭﺓ. 1.3 ﺍﻟﺪﻭﺭﺍﻥ ﺍﻟﺘﻠﻘﺎﺋﻲ ﻟﻠﻬﻮﺍﺀ • ﺍﺿﻐﻂ ﺯﺭ SWINGﻟﺘﻨﺸﻴﻂ ﻭﻇﻴﻔﺔ ﺩﻭﺭﺍﻥ ﺍﻟﻬﻮﺍﺀ. • ﻟﺘﻮﺯﻳﻊ ﺍﻟﻬﻮﺍﺀ ﺑﺎﺗﺠﺎﻩ ﻣﻌﻴﻦ ،ﺍﺿﻐﻂ ﺯﺭ SWINGﻭﺍﻧﺘﻈﺮ ﺍﻟﻰ ﺍﻥ ﻳﺘﺤﺮﻙ ﺍﻟﺸﻖ ﺑﺎﻻﺗﺠﺎﻩ ﺍﻟﻤﺮﻏﻮﺏ ﻭﺍﺿﻐﻂ ﺍﻟﺰﺭ ﻣﺮﺓ ﺍﺧﺮﻯ. ﻃﺮﻳﻘﺔ ﺍﺧﺘﻴﺎﺭ ﻭﺿﻊ ﺍﻟﺘﺄﺭﺟﺢ ﻟﻠﻤﻮﺩﻳﻞ )ﺣﺴﺐ ﺍﻟﻄﺮﺍﺯ( • ﺍﺿﻐﻂ ﺍﻟﺰﺭ ( ) SWINGﻟﻤﺪﺓ 4ﺛﻮﺍﻥ ﻟﻠﺪﺧﻮﻝ ﻓﻲ ﻭﺿﻊ ﺿﺒﻂ ﺍﻟﺤﻘﻞ .ﺃﺛﻨﺎﺀ ﻭﺿﻊ ﺿﺒﻂ ﺍﻟﺤﻘﻞ ،ﺳﻮﻑ ﻳﺘﻢ ﻓﻘﻂ ﺑﻴﺎﻥ ) ( .SWING MODE • ﺍﺿﻐﻂ ﺯﺭ ﺩﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ ﻭ ﻻﺧﺘﻴﺎﺭ ﺗﺪﻭﻳﺮ ﻭﺿﻊ ﺍﻟﺘﺄﺭﺟﺢ ( ) SWING MODEﻣﻦ ﻭﺿﻊ ﺗﺄﺭﺟﺢ 1ﺇﻟﻰ ﻭﺿﻊ ﺗﺄﺭﺟﺢ .3 • ﻳﻮﺟﺪ 3ﺃﻭﺿﺎﻉ ﺗﺄﺭﺟﺢ SWING MODEﻣﺨﺘﻠﻔﺔ ،ﻭﻫﻲ: ﻭﺿﻊ ﺍﻟﺘﺄﺭﺟﺢ 1ﻭﺿﻊ ﺍﻟﺘﺄﺭﺟﺢ 2ﻭﺿﻊ ﺍﻟﺘﺄﺭﺟﺢ 3 ﺳﻮﻑ ﻻ ﻳﺘﻢ ﺗﻨﺸﻴﻂ ﻭﺿﻊ ﺗﺄﺭﺟﺢ SWING MODEﺇﻻ ﺇﺫﺍ ﺗﻢ ﺗﻨﺸﻴﻂ ﻭﻇﻴﻔﺔ ﺍﻟﺘﺄﺭﺟﺢ .SWING ﺍﻟﺘﺄﺭﺟﺢ ﻣﺆﺷﺮ ﺑﺎﻟﻌﻠﺎﻣﺔ: • ﻓﻲ ﺣﺎﻟﺔ ﻋﺪﻡ ﺗﻐﻴﻴﺮ ﺍﻟﻮﺿﻊ ﺧﻠﺎﻝ 4ﺛﻮﺍﻥ ،ﺳﻮﻑ ﺗﺸﺘﻐﻞ ﺍﻟﻮﺣﺪﺓ ﺣﺴﺐ ﻭﺿﻊ ﺍﻟﺘﺄﺭﺟﺢ ) SWING MODE ﺍﻟﻤﺨﺘﺎﺭ. ( 1.4 ﺳﺮﻋﺔ ﺍﻟﻤﺮﻭﺣﺔ ﺍﻟﻬﺎﺩﺋﺔ QUIET ﺍﺿﻐﻂ ﻣﻔﺘﺎﺡ ﺳﺮﻋﺔ ﺍﻟﻤﺮﻭﺣﺔ ﺍﻟﻬﺎﺩﺋﺔ QUIETﻣﺮﺓ ﻭﺍﺣﺪﺓ ﻟﺘﻨﺸﻴﻂ ﺳﺮﻋﺔ ﺍﻟﻤﺮﻭﺣﺔ ﺍﻟﻬﺎﺩﺋﺔ .ﺳﻮﻑ ﻳﻈﻬﺮ ﺭﻣﺰ ﺍﻟﺴﺮﻋﺔ ﺍﻟﻬﺎﺩﺋﺔ .QUIETﻹﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﺳﺮﻋﺔ ﺍﻟﻤﺮﻭﺣﺔ ﺍﻟﻬﺎﺩﺋﺔ ﻭﺍﻟﺮﺟﻮﻉ ﺇﻟﻰ ﺳﺮﻋﺔ ﺍﻟﻤﺮﻭﺣﺔ ﺍﻟﺴﺎﺑﻘﺔ ،ﺍﺿﻐﻂ ﻣﻔﺘﺎﺡ ﺍﻟﻬﺎﺩﺉ QUIETﻣﺮﺓ ﺛﺎﻧﻴﺔ .ﺇﺫﺍ ﺿﻐﻂ ﺍﻟﻤﺴﺘﻌﻤﻞ ﺯﺭ ﺍﻟﻤﺮﻭﺣﺔ FANﺃﻭ ﺯﺭ ﺍﻟﺘﺮﺑﻮ TURBOﺃﻭ ﺃﻭﻗﻒ ﺗﺸﻐﻴﻞ ﺍﻟﻮﺣﺪﺓ ،ﺳﻮﻑ ﻳﺘﻢ ﺇﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﺍﻟﺴﺮﻋﺔ ﺍﻟﻬﺎﺩﺋﺔ .ﻫﺬﻩ ﺍﻟﺴﺮﻋﺔ ﻓﻌﺎﻟﺔ ﻓﻘﻂ ﺃﺛﻨﺎﺀ ﻭﺿﻊ ﺍﻟﺘﺒﺮﻳﺪ COOLﻭﺍﻟﺘﺪﻓﺌﺔ HEATﻟﻠﻤﻮﺩﻳﻠﺎﺕ ﺍﻟﻤﺨﺘﺎﺭﺓ. 1.5 ﺯﺭ ﺿﺒﻂ ﺩﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ ” “ ﺍﻭ ” “ ﺍﺿﻐﻂ ﺯﺭ ﺩﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ ﻭﺍﺿﺒﻂ ﺍﻟﺪﺭﺟﺔ ﺣﺴﺐ ﺭﻏﺒﺘﻚ .ﺑﻮﺍﺳﻄﺔ ﺿﻐﻂ ﺯﺭ ” “ ﺍﻭ ” “ ﻣﺮﺓ ﻭﺍﺣﺪﺓ ،ﺗﺘﻐﻴﺮ ﺩﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ ﺑﻮﺍﺳﻄﺔ °1ﻣﺌﻮﻳﺔ ﺍﻭ °1ﻓﻬﺮﻧﻬﺎﻳﺖ .ﻣﺪﻯ ﺿﺒﻂ ﺩﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ ﺍﻷﺻﻠﻲ ﻫﻮ ﻣﻦ 16ﺩﺭﺟﺔ ﻣﺌﻮﻳﺔ ﺇﻟﻰ 30ﺩﺭﺟﺔ ﻣﺌﻮﻳﺔ )60 ﺩﺭﺟﺔ ﻓﻬﺮﻧﻬﺎﺗﻴﺔ ﺇﻟﻰ 86ﺩﺭﺟﺔ ﻓﻬﺮﻧﻬﺎﺗﻴﺔ( .ﻋﻨﺪﻣﺎ ﻳﺘﻢ ﺿﺒﻂ ﺍﻻﺧﺘﻴﺎﺭ 20ﺇﻟﻰ 30ﺩﺭﺟﺔ ﻣﺌﻮﻳﺔ ،ﻳﺘﻢ ﺿﺒﻂ ﻧﻬﺎﻳﺔ ﻣﺪﻯ ﺩﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ ﻋﻠﻰ 20ﺩﺭﺟﺔ ﻣﺌﻮﻳﺔ ﺇﻟﻰ 30ﺩﺭﺟﺔ ﻣﺌﻮﻳﺔ ) 68ﺩﺭﺟﺔ ﻓﻬﺮﻧﻬﺎﺗﻴﺔ ﺇﻟﻰ 86ﺩﺭﺟﺔ ﻓﻬﺮﻧﻬﺎﺗﻴﺔ( .ﺿﻐﻂ ﻛﻼ ﻣﻦ ﺍﻟﻤﻔﺘﺎﺣﻴﻦ ﻣﻊ ﺑﻌﺾ ﺑﻨﻔﺲ ﺍﻟﻮﻗﺖ ﻳﺤﻮﹼﻝ ﺿﺒﻂ ﺍﻟﺤﺮﺍﺭﺓ ﺑﻴﻦ ﺍﻟﺪﺭﺟﺔ ﺍﻟﻤﺌﻮﻳﺔ ﻭﺍﻟﺪﺭﺟﺔ ﺍﻟﻔﻬﺮﻧﻬﺎﺗﻴﺔ .ﺿﺒﻂ ﺍﻟﺤﺮﺍﺭﺓ ﻏﻴﺮ ﻣﺴﻤﻮﺡ ﺃﺛﻨﺎﺀ ﻭﺿﻊ ﺍﻟﻤﺮﻭﺣﺔ ) FANﻻ ﻳﻮﺟﺪ ﻋﺮﺽ ﻟﻠﺤﺮﺍﺭﺓ ﺍﻟﻤﻀﺒﻮﻃﺔ( .ﻻ ﻳﻮﺟﺪ ﻋﺮﺽ ﻟﺪﺭﺟﺔ ﺣﺮﺍﺭﺓ ﺍﻟﻐﺮﻓﺔ. 1.6 ﻭﻇﻴﻔﺔ ﺍﻟﻨﻮﻡ SLEEP ﺍﺿﻐﻂ ﺯﺭ ﺍﻟﻨﻮﻡ SLEEPﻟﺘﺸﻐﻴﻞ ﻭﺿﻊ ﺍﻟﻨﻮﻡ .ﻭﻇﻴﻔﺔ ﺍﻟﻨﻮﻡ SLEEPﻏﻴﺮ ﻣﺘﻮﻓﺮﺓ ﻓﻲ ﻭﺿﻊ ﺍﻟﺘﺠﻔﻴﻒ DRY ﻭﺍﻟﻤﺮﻭﺣﺔ .FAN 1.7 ” “ON TIMERﻭ ”“OFF TIMER ﺗﺤﺘﻮﻱ ﻫﺬﻩ ﺍﻟﻮﺣﺪﺓ ﻋﻠﻰ ﻣﺆﻗﺖ - 2ﺣﺪﺙ ،ﻭﻫﺬﺍ ﻳﻌﻨﻲ ﺃﻥ ﺍﻟﻮﺣﺪﺓ ﺗﺤﺘﻮﻱ ﻋﻠﻰ ﻣﺆﻗﺖ 1ﻭ ﻣﺆﻗﺖ ،2ﻭﻛﻞ ﺣﺪﺙ ﻳﻤﺘﻠﻚ ﻣﺆﻗﺖ ﺗﺸﻐﻴﻞ ON TIMERﻭﻣﺆﻗﺖ ﺇﻳﻘﺎﻑ .OFF TIMERﻓﻌﺎﻟﻴﺔ ﺿﻐﻂ ﺍﻟﻤﻔﺘﺎﺡ ﻟﻤﺆﻗﺖ ﺍﻟﺘﺸﻐﻴﻞ ONﻭﻣﺆﻗﺖ ﺍﻹﻳﻘﺎﻑ OFFﻣﺒﻴﻨﺔ ﻓﻲ ﺍﻟﺠﺪﻭﻝ .1.1 ١ ﺗﺮﺟﻤﺔ ﺍﻟﺘﻌﻠﻴﻤﺎﺕ ﺍﻻﺻﻠﻴﺔ 1.1 ﺯﺭ MODE ﺍﺿﻐﻂ ﺯﺭ MODEﻟﺘﺤﻮﻳﻞ ﺍﻟﺘﺸﻐﻴﻞ ﻣﻦ .FAN ،DRY*،AUTO* ،HEAT* ،COOLﺍﻓﺤﺺ ﺍﻟﻌﺎﺭﺿﺔ ﻟﻤﺸﺎﻫﺪﺓ ﻣﺎﻫﻮ ﺍﻟﻮﺿﻊ ﺍﻟﺬﻱ ﺿﺒﻄﺖ ﺍﻟﺘﺤﻜﻢ ﻋﻠﻴﻪ .ﻭﻇﻴﻔﺔ ﺍﻟﺘﺴﺨﻴﻦ * ،HEATﺍﻟﺘﻠﻘﺎﺋﻲ AUTOﻭ ﺍﻟﺘﺠﻔﻴﻒ DRYﻫﻲ ﻓﻘﻂ ﻟﻠﻤﻮﺩﻳﻼﺕ ﺍﻟﻤﺨﺘﺎﺭﺓ. ﺍﻟﻌﺮﺑﻴﺔ ﺍﻟﺘﻌﻠﻴﻤﺎﺕ ﺍﻟﺘﺸﻐﻴﻞ ﻣﺒﻴﻨﺎﺕ ﻭﺣﺪﺓ ﺍﻟﺘﺤﻜﻢ BRC51A61/62 ON 12 OFF 12 MON TUE WED THU FRI SAT SUN ALL AM PM F C 4 5 QUIET 6 7 12 13 ﺍﻟﺮﻗﻢ SET TEMP. SLEEP OVERRIDE AUTO 12 FAN HEAT SLEEP SWING AUTO COOL TURBO QUIET SWING TURBO TIMER TIMER OFF DRY ON ON / OFF MODE DELAY TIMER FAN ﻣﻔﺘﺎﺡ 3 2 1 10 9 11 8 ﺍﻟﻮﻇﻴﻔﺔ .1 MODE ﻣﻔﺘﺎﺡ ﺍﻟﺘﺤﻜﻢ ﺑﺎﺧﺘﻴﺎﺭ ﺍﻭﺿﺎﻉ ﺍﻟﺘﺸﻐﻴﻞ )(Cool / Heat / Auto / Dry / Fan .2 TURBO ﺗﺸﻐﻴﻞ/ﺇﻳﻘﺎﻑ ﻭﻇﻴﻔﺔ ﺍﻟﺘﺮﺑﻮ .3 SWING ﺗﻨﺸﻴﻂ/ﺗﻌﻄﻴﻞ ﻣﻔﺘﺎﺡ ﺍﻟﺘﺤﻜﻢ ﺑﺎﻟﺘﺄﺭﺟﺢ ﺍﺿﻐﻂ ﺍﻟﻤﻔﺘﺎﺡ ﻟﺘﻐﻴﻴﺮ ﻭﺿﻊ ﺍﻟﺘﺄﺭﺟﺢ .4 QUIET ﺗﺸﻐﻴﻞ/ﺇﻳﻘﺎﻑ ﻭﻇﻴﻔﺔ ﺍﻟﻬﺎﺩﺉ .5 SET TEMP UP ﺯﻳﺎﺩﺓ ﺩﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ ﺍﻟﻤﻀﺒﻮﻃﺔ ﺑﺪﺭﺟﺔ ﻣﺌﻮﻳﺔ ﺍﻭ ﻓﻬﺮﻧﺎﻳﺘﻴﺔ .6 SET TEMP DOWN ﺗﻘﻠﻴﻞ ﺩﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ ﺍﻟﻤﻀﺒﻮﻃﺔ ﺑﺪﺭﺟﺔ ﻣﺌﻮﻳﺔ ﺍﻭ ﻓﻬﺮﻧﺎﻳﺘﻴﺔ .7 SLEEP ﺗﻨﺸﻴﻂ/ﺗﻌﻄﻴﻞ ﻭﻇﻴﻔﺔ ﺍﻟﻨﻮﻡ .8 OFF TIMER ﺗﻨﺸﻴﻂ/ﺗﻌﻄﻴﻞ ﺍﻟﻨﺘﻴﺠﺔ 1ﻭ 2ﻣﻦ ﻭﺿﻊ ﺗﻬﻴﺌﺔ ﺍﻟﻤﺆﻗﺖ OFF TIMER .9 ON TIMER ﺗﻨﺸﻴﻂ/ﺗﻌﻄﻴﻞ ﺍﻟﻨﺘﻴﺠﺔ 1ﻭ 2ﻣﻦ ﻭﺿﻊ ﺗﻬﻴﺌﺔ ﺍﻟﻤﺆﻗﺖ ON TIMER .10 DELAY TIMER ﺗﺸﻐﻴﻞ/ﺇﻳﻘﺎﻑ ﻣﺆﻗﺖ ﺍﻟﺘﺄﺧﻴﺮ .11 FAN ﻣﻔﺘﺎﺡ ﺍﻟﺘﺤﻜﻢ ﺑﺎﺧﺘﻴﺎﺭ ﺳﺮﻋﺔ ﺍﻟﻤﺮﻭﺣﺔ )(Auto / High / Med / Low .12 ON/OFF ﺗﺸﻐﻴﻞ/ﺍﻳﻘﺎﻑ ﺍﻟﻮﺣﺪﺓ ﻣﻊ ﺍﺑﻄﺎﻝ ﺟﻤﻴﻊ ﺗﻬﻴﺌﺎﺕ ﺍﻟﻤﺆﻗﺖ .13 (RTC) REAL TIME CLOCK ﺗﺸﻐﻴﻞ/ﺍﻳﻘﺎﻑ ﻭﺿﻊ ﺗﻬﻴﺌﺔ ﺳﺎﻋﺔ ﺍﻟﻮﻗﺖ ﺍﻟﺼﺤﻴﺢ )(RTC ﻣﻼﺣﻈﺔ: ﻭﻇﻴﻔﺔ ﺍﻟﺘﺮﺑﻮ ﻭ ﺍﻟﻬﺎﺩﺉ ﻫﻲ ﻓﻘﻂ ﻟﻠﻤﻮﺩﻳﻼﺕ ﺍﻟﻤﺨﺘﺎﺭﺓ. ii i ﻛﺘﻴﺐ ﺍﻟﺘﺸﻐﻴﻞ ﻋﺮﺑﻲ ﻛﺘﻴﺐ ﺍﻟﺘﺸﻐﻴﻞ ﺳﻤﺎﻋﺔ ﺍﻟﺴﻠﻜﻴﺔ AUTO ON 12 OFF 12 MON TUE WED THU FRI SAT SUN ALL OVERRIDE 12 DRY AUTO COOL TURBO QUIET MODE DELAY TIMER FAN SWING SLEEP SWING TIMER TIMER ON AM PM F C SET TEMP. TURBO FAN OM-SLM9-0911(1)-DAIKIN R08019037014A :ﺭﻗﻢ ﺍﳉﺰﺀ HEAT OFF QUIET SLEEP ON / OFF
advertisement
Key Features
- Wireless control
- Temperature setting
- Fan speed selection
- Timer function
- Turbo mode
- Quiet mode
Related manuals
Frequently Answers and Questions
How do I select the operating mode of the air conditioner?
Press the MODE button to switch between COOL, HEAT, AUTO, DRY, and FAN modes.
What is the Turbo mode for?
The Turbo mode increases fan speed for faster cooling or heating.
How do I set the timer to turn the air conditioner on or off?
Use the ON TIMER or OFF TIMER keys, you can create two separate events.