WOLFVISION Cynap Pure Pro Outstanding Wireless Presentation and Collaboration Installation Guide
PDF
Dokument
Reklama
Reklama
WolfVision GmbH Oberes Ried 14 A-6833 Klaus / AUSTRIA 1 Tel. +43-5523-52250 Fax +43-5523-52249 E-Mail: [email protected] www.wolfvision.com WolfVision GmbH Oberes Ried 14 A-6833 Klaus / AUSTRIA Tel. +43-5523-52250 Fax +43-5523-52249 E-Mail: [email protected] www.wolfvision.com vSolution Cynap Pure Pro Network Integration 1. Basics .......................................................................................................................... 3 2. Glossary ....................................................................................................................... 3 2.1. LAN / Ethernet settings ............................................................................................ 3 2.2. WLAN settings – access point ................................................................................. 4 2.3. WLAN settings – infrastructure (Cynap Pure Pro acts as client) ............................... 5 2.4. Date and time (General Settings) ............................................................................. 6 2.5. Host name (General Settings).................................................................................. 6 2.6. LAN / WLAN port ..................................................................................................... 6 2.7. Proxy settings .......................................................................................................... 8 2.8. Security ................................................................................................................... 9 3. Network integration (examples) ...................................................................................10 3.1. Stand-alone access point mode (without wired network integration) .......................10 3.2. Cynap Pure Pro wireless network access point mode .............................................11 3.3. Cynap Pure Pro network infrastructure mode .........................................................12 4. Firewall rules ...............................................................................................................14 5. Differences in Open Mode / Protected Mode ...............................................................19 6. BYOD ..........................................................................................................................20 7. User interface ..............................................................................................................21 8. Hardware and OS........................................................................................................22 9. Administration .............................................................................................................22 10. Bandwidth Measurement Data ....................................................................................23 10.1. PowerPoint Presentation ........................................................................................23 10.2. Multimedia from Notebook to Cynap Pure Pro using vCast Software ......................23 11. Client System Requirements .......................................................................................24 12. Index ...........................................................................................................................25 2 WolfVision GmbH Oberes Ried 14 A-6833 Klaus / AUSTRIA Tel. +43-5523-52250 Fax +43-5523-52249 E-Mail: [email protected] www.wolfvision.com 1. Basics Before starting, check the existing infrastructure and define the required equipment and settings. Various examples in this document show the different ways in which Cynap Pure Pro can be integrated into the network. When connecting Cynap Pure Pro to LAN and WLAN at the same time, please use different IP ranges in order to prevent address conflicts. The listed IP addresses are only examples. Cynap Pure Pro can be treated as a standard network device and it is as secure as the supporting network. Cynap Pure Pro cannot be considered as a router, switch or firewall. Communication to other networks and access must to be controlled using your existing equipment (firewall, router, switch and so on). By default, the built-in access point is enabled, SSID and password are the serial number of the unit (inclusive leading zero, e.g. 0106406). 2. Glossary This glossary will assist you in setting up the network correctly. Please note that in order to connect Cynap Pure Pro to an existing company network, some information from the local administrator is required. 2.1. LAN / Ethernet settings Priority Interface Access DHCP IP address Subnet mask Gateway Name server 1 / 2 Identity Anonymous Identity Authentication Method Root Certificate The higher prioritized interface (value = 1) will be used for network services first. Ensure that the value is different from the WLAN interface priority. Cynap Pure Pro will get all network settings automatically from the DHCP server in the existing network. Switch it to OFF to set the static addresses manually. Unique address in the network, i.e. 192.168.0.100. The IP address of Cynap Pure Pro can for example be set to 192.168.0.1. Available IP addresses can be limited. A commonly used subnet mask would be 255.255.255.0 Defines the IP address of the server / connection to other networks (such as the internet). When Cynap Pure Pro is directly connected only to a PC, then enter the IP address of the PC. Input the IP address of the preferred Domain Name System (DNS). This Server translates domain names into corresponding IP addresses. Login credentials to connect Cynap Pure Pro in a protected network. (802.1x). The identity to be used on an unencrypted session before Identity is being validated on an encrypted session. Supported are PEAP with MSCHAPv2 and TTLS-PAP Only root certificates are supported, load the certificate by using the Web Interface through the WLAN interface. Allowed certificates: • root certificate (CA) with common file extension .crt Base-64-coded X.509 encoded DER certificate 3 WolfVision GmbH Oberes Ried 14 A-6833 Klaus / AUSTRIA Tel. +43-5523-52250 Fax +43-5523-52249 E-Mail: [email protected] www.wolfvision.com • Privacy Enhanced Mail with common file extension .perm Base-64-coded X.509 encoded DER certificate certificate stored between 2 tags: “---Begin Certificate---“and” ------End Certificate-----“ 2.2. WLAN settings – access point Mode OFF Mode Access Point Region Channel IP address Subnet mask Disable access point. Enable access point. Select the region where Cynap will be operated (US-region or others). Defines the channel used for wireless communication. For optimum performance, select a currently unused channel. Defines the IP address of the access point. Cynap Pure Pro acts as a DHCP server and provides the necessary network settings to the connected devices. Available IP addresses can be limited. A commonly used subnet mask would be 255.255.255.0 4 WolfVision GmbH Oberes Ried 14 A-6833 Klaus / AUSTRIA Tel. +43-5523-52250 Fax +43-5523-52249 E-Mail: [email protected] www.wolfvision.com 2.3. WLAN settings – infrastructure (Cynap Pure Pro acts as client) Use the access point list to check the currently available access point and its signal strength. Mode Infrastructure Band Priority Interface Access BSSID On / Off SSID BSSID Subnet mask Gateway IP Name server 1 / 2 Encryption Identity Anonymous Identity Authentication Method Root Certificate Enable Infrastructure, Cynap Pure Pro can be connected as client to an existing access point. By default, Cynap Pure Pro uses the 2.4GHz and 5 GHz frequency band. The used frequency band can be limited to either 2.4GHz or 5 GHz. This setting is available in SSID mode only. The higher prioritized interface (value = 1) will be used for network services first. Ensure that the value is different from the LAN interface priority. Use the button to toggle between SSID and BSSID mode. With BSSID (Basic Service Set Identification), the used access point will be fixed and Cynap Pure Pro will connect to the defined access point only. Access point hopping, which is available in SSID mode (Service Set Identification), will be prevented. Defines the network name in plain text for easy identification of the WLAN network. Check existing WLAN infrastructure to get SSID. Following characters are supported: - AaBbCcDdEeFfGgHhIiJjKkLlMmNnOoPpQqRrSsTtUuV vWwXxYyZz - 0123456789 - _-:$& () Defines the network name in plain text for easy identification of the WLAN network. Check existing WLAN infrastructure to get SSID. This setting is available in SSID mode only. Available IP addresses can be limited. A commonly used subnet mask would be 255.255.255.0 Defines the IP address of the server / connection to other networks (such as the internet). When Cynap Pure Pro is directly connected only to a PC, then enter the IP address of the PC. Input the IP address of the preferred Domain Name System (DNS). This Server translates domain names into corresponding IP addresses. Defines encryption for safe network traffic. All connected units must use the same algorithm (None, WEP, WPA2, WPA2 Enterprise). Login credentials to connect Cynap Pure Pro in a WPA Enterprise protected network. The identity to be used on an unencrypted session before Identity is being validated on an encrypted session. Supported are PEAP with MSCHAPv2 and TTLS-PAP Only root certificates are supported, load the certificate by using the Web Interface through the LAN interface. Allowed certificates: • root certificate (CA) with common file extension .crt Base-64-coded X.509 encoded DER certificate 5 WolfVision GmbH Oberes Ried 14 A-6833 Klaus / AUSTRIA Tel. +43-5523-52250 Fax +43-5523-52249 E-Mail: [email protected] www.wolfvision.com • Privacy Enhanced Mail with common file extension .perm Base-64-coded X.509 encoded DER certificate certificate stored between 2 tags: “---Begin Certificate---“and” -----End Certificate-----“ Signal Level Limit (dBm) Signal Level Reconnect Counter (Connection Loss) Reconnect Counter (Low Signal Level) Defines when Cynap Pure Pro start to search for another access point with the same SSID in your infrastructure (WLAN roaming). Monitoring the current signal level to prevent too low values. Lookups could interrupt the network connection shortly and every lookup will be counted (Reconnect Counter (Low Signal Level). Shows the current strength of the WLAN signal in dBm. Counts every connection loss, e.g. when the selected access point would be powered down. Counts every lookup then the measured signal falls below the user defined signal level limit. 2.4. Date and time (General Settings) Time source Cynap Pure Pro has a built-in battery-buffered RTC clock (Real Time Clock). Settings will only be lost if the battery is empty. To eliminate the risk of incorrect time stamps, Cynap Pure Pro can be synchronized to an external time server. Select external and input a valid IP address or URL of a NTP time server. 2.5. Host name (General Settings) Host name The Host name can be changed in the settings under general settings. The host name can be useful for network administrators to see the device name in plain text in the list of clients. Please note, this host name is not automatically listed in the DNS list, and therefore cannot be used in a browser without DNS registration. 2.6. LAN / WLAN port The LAN port enables integration of Cynap Pure Pro into an internal network. Administrators of a large number of Cynap Pure Pro systems can use the LAN port to control, support and update all of their units from their local desktop PC. The list of applications for the Cynap Pure Pro LAN port is constantly increasing. It can be used for controlling, capturing still images, viewing live video streams, firmware updates, adjustments, menu settings and for maintenance purposes. Some features are only supported when using vSolution Link software. The following protocols are supported: TCP/IP, IGMP, RTP, RTSP, UDP and ARP. Supported (tested) internet browsers are: Microsoft Edge, Firefox, Chrome, and Safari. By default, DHCP is activated to receive all network settings automatically from the server. Hint - WLAN: 6 WolfVision GmbH Oberes Ried 14 A-6833 Klaus / AUSTRIA Tel. +43-5523-52250 Fax +43-5523-52249 E-Mail: [email protected] www.wolfvision.com To ensure optimal performance of supplied remote control (optional), prevent channel 13 in the band of 2.4 GHz. Switch Cynap Pure Pro to standby closes all connections. 7 WolfVision GmbH Oberes Ried 14 A-6833 Klaus / AUSTRIA Tel. +43-5523-52250 Fax +43-5523-52249 E-Mail: [email protected] www.wolfvision.com 2.7. Proxy settings To increase security level, use a proxy server to control HTTP and HTTPS traffic from Cynap Pure Pro. Built-in access point and other local services are not controlled. To take effect the new settings, Cynap Pure Pro will reboot automatically. Proxy enable URL Host Port Authentication Username Password Enable / disable proxy service When enable, all HTTP and HTTPS traffic will be routed to your proxy server. URL of the proxy server in your network, like 104.236.10.17 (or DNS name up to 256 characters, no space between the characters). DNS server not required, when using IP addresses. Port, set the used network port to connect to your proxy server. Disable / enable Authentication When enabled, valid user name and password has to be entered. Username, given by your server. Password, given by your server. 8 WolfVision GmbH Oberes Ried 14 A-6833 Klaus / AUSTRIA Tel. +43-5523-52250 Fax +43-5523-52249 E-Mail: [email protected] www.wolfvision.com 2.8. Security Admin password Defines the necessary password for administrator access. This login data is needed to change the Ethernet Mode, and an existing administrator password. Using the login data, an administrator can connect to Cynap Pure Pro at any time. The default password is “Password”. Remember to make a note of any changed passwords! Login Security Accessing Cynap Pure Pro can be protected by authentication (admin, moderator or PIN). To prevent unauthorized access of the settings, the admin password needs to be entered once per session. Network Security Accessing Cynap Pure Pro can be limited to secure connections only (https). Please note, the accessing application needs to support SSL / TLS (e.g. the most modern browsers are supporting HTML5 and SSL /TLS). Wolfvision support access can be prohibited by disabling SSH. LAN Security When using wired network, use authentication (according 802.1x) to maximize security. When using certificates, load it busy using the Web Interface. WLAN (WiFi) Security When using wireless network, use encryption to maximize security. Cynap Pure Pro complies with following standards: • WEP • WPA2 • WPA2 Enterprise (according 802.1x) Hint WEP allows password with a length of 13 characters. WPA2 allows password with a length of 8 ~ 63 characters. Use special characters carefully, not every third party device can handle it. When using WPA2 Enterprise, load the certificate by using the Web Interface. 9 WolfVision GmbH Oberes Ried 14 A-6833 Klaus / AUSTRIA Tel. +43-5523-52250 Fax +43-5523-52249 E-Mail: [email protected] www.wolfvision.com 3. Network integration (examples) The following examples are showing different ways to integrate Cynap Pure Pro into your network infrastructure, one network and one wireless network. BYOD (bring your own device) allows sharing the screen content of different devices with various operating systems to Cynap Pure Pro to share to a big display device. 3.1. Stand-alone access point mode (without wired network integration) Cynap Pure Pro is operated in stand-alone access point mode. Cynap Pure Pro is acting as DHCP server to provide the addresses to your WLAN devices. Cynap generates an independent WLAN, and WLAN enabled devices (BYOD) can connect to Cynap Pure Pro. Advantages: - No complex network infrastructure necessary - Cynap Pure Pro generates its own stand-alone access point - No connection to internal IT infrastructure - Security issues - no other unit from the internal IT infrastructure can access Cynap Pure Pro Disadvantages: - No devices have internet access Required settings: DHCP Switch to OFF to enable manual setting of addresses IP Address Unique address in the network, like 192.168.0.100. The IP address of a connected PC could be set to 192.168.0.1 for maintenance purposes Subnet Mask Available IP addresses can be limited. A commonly used subnet mask would be 255.255.255.0 Gateway Enter the IP address of a directly connected PC for maintenance purposes Name server Not needed 10 WolfVision GmbH Oberes Ried 14 A-6833 Klaus / AUSTRIA Tel. +43-5523-52250 Fax +43-5523-52249 E-Mail: [email protected] www.wolfvision.com 3.2. Cynap Pure Pro wireless network access point mode Cynap Pure Pro integrated via a cable connection into an existing network, and operates in wireless network access point mode additionally. LAN settings for Cynap Pure Pro can be obtained from an existing DHCP server. Cynap Pure Pro generates an independent WLAN, and WLAN enabled (BYOD) can connect to Cynap Pure Pro. Advantages: - All devices can communicate with each other - Cynap Pure Pro has access to the internet. - Cynap Pure Pro can access the internet to check for firmware updates without using additional devices - Security issues – BYOD devices over the access point have no access to the existing network and internet. Disadvantages: - Performance issues (all traffic is on the same network) Hint: If the units are in different subnets, Cynap Pure Pro might not be able to be discovered automatically by vSolution applications. 11 WolfVision GmbH Oberes Ried 14 A-6833 Klaus / AUSTRIA Tel. +43-5523-52250 Fax +43-5523-52249 E-Mail: [email protected] www.wolfvision.com 3.3. Cynap Pure Pro network infrastructure mode Cynap Pure Pro is integrated to an existing wired network (e.g. Corporate network) wired, and additionally connected to a wireless network (e.g. Guest network as separate VLAN). LAN and WLAN settings for Cynap Pure Pro can be obtained from an existing DHCP server. All devices of the Corporate and also the Guest network can be connected to Cynap Pure Pro. Advantages: - All devices can communicate with each other - Cynap Pure Pro has access to the internet. - Cynap Pure Pro can be moved within the range of the access point - Cynap Pure Pro can access the internet to check for firmware updates without using additional devices Disadvantage: - Performance issues (all traffic is on the same network) Hint: If the units are in different subnets, Cynap Pure Pro might not be able to be discovered automatically by vSolution applications. 12 WolfVision GmbH Oberes Ried 14 A-6833 Klaus / AUSTRIA Cynap Pure Pro can also be installed in a VLAN. 13 Tel. +43-5523-52250 Fax +43-5523-52249 E-Mail: [email protected] www.wolfvision.com WolfVision GmbH Oberes Ried 14 A-6833 Klaus / AUSTRIA Tel. +43-5523-52250 Fax +43-5523-52249 E-Mail: [email protected] www.wolfvision.com 4. Firewall rules Cynap Pure Pro has firewall rules that must be adhered to in order to allow successful network communications, and the corresponding services to be used. To use services with user defined addresses and ports, be sure these are not blocked by your firewall. Function / Application Inbound / Outbound Description TCP / UDP UDP TCP TCP TCP Inbound / Outbound Inbound Inbound Inbound Inbound Inbound Multicast DNS (mDNS 224.0.0.251) Bonjour Audio for Airplay Audio for Airplay Primary Airplay communication Airplay video communication Airplay audio communication 4100 4101 5000 TCP / UDP UDP TCP Inbound Inbound Inbound 7000 7100 47000 TCP TCP TCP Inbound Inbound Inbound Audio for Airplay Audio for Airplay AirPlay communication with legacy devices Primary Airplay communication Airplay video communication Airplay audio communication 5353 UDP 1900 4100 – 4164 8008 UDP TCP / UDP Inbound / Outbound Inbound Inbound Multicast DNS (mDNS 224.0.0.251) Chromecast discovery Audio for Chromecast TCP Inbound 8009 32768 – 61000 TCP UDP Inbound Inbound /Outbound Primary Chromecast communication Communication Chromecast Chromecast (video data stream) 5353 UDP Inbound 67 / 68 UDP Inbound UDP Inbound RTSP Control 19000 – 19007 19010 – 19017 7236 TCP Outbound MS-MICE Control 7250 TCP Inbound / Outbound Touchback 50000 TCP Outbound Hardware cursor extension 19020 – 19027 UDP Inbound Airplay Multicast DNS (mDNS) Audio Audio Airplay Video Audio Airplay Bluetooth Audio Audio AirPlay Airplay Video Audio Chromecast Multicast DNS (mDNS) Discovery Audio Chromecast Chromecast Video data stream Miracast MS-MICE Multicast DNS (mDNS) DHCP RTP Stream Port Type 5353 UDP 4100 4101 7000 7100 47000 14 Multicast DNS (mDNS 224.0.0.251) DHCP communication between device and receiver RTP media traffic port for delivering audio and video RTSP control port is used to establish and manage session Control port on which Cynap family system listen for Miracast packets when over existing network mode is enabled This port is for touchback to send mouse events back between Cynap to the Windows computer. If this port is blocked, bi-directional inputs is not possible. Hardware cursor to reduce latency when using touchback. WolfVision GmbH Oberes Ried 14 A-6833 Klaus / AUSTRIA Wake On LAN 19030 – 19037 7/9 UDP FTP 21 TCP Inbound / Outbound Inbound SSH http, Cynap control 22 80 TCP TCP Inbound Inbound https, SSL, e.g. Cloud Service, Cynap control 443 TCP / UDP Inbound Proxy 8080 TCP / UDP Outbound NFS CIFS NTP 111 / 2049 137 /139 123 TCP / UDP TCP / UDP UDP Outbound Outbound Outbound LDAP LDAPS PJLink 389 636 4352 TCP / UDP TCP / UDP TCP Outbound Outbound Outbound vSolution Cast Discovery Multicast 50000 UDP Inbound Device Discovery 50913 UDP Inbound For control purposes 50915 TCP Inbound TLS Control 50917 TCP Inbound Video streams 50921 TCP Inbound 15 Tel. +43-5523-52250 Fax +43-5523-52249 E-Mail: [email protected] www.wolfvision.com Usually port 7 is used for sending the magic packet Connection to FTP server. This port will also be used to check for available Feature Pack and Warranty Pack updates. Access for Wolfvision support This port used to connect to Cynap web interface (httpd). If this port is blocked, no connection can be made. This port is used to cloud service and for secure connect to Cynap web for secure connect to Cynap web interface. If this port is blocked, no connection can be made. Default port proxy function (This port can be changed in the Proxy settings). Connection to network drives Connection to network drives For optional clock synchronization by a time server (Network Time Protocol, NTP) Connection to LDAP server Connection to LDAPS server (TLS) This is the default port for PJLink and cab be changed in the settings (Peripheral Control) This port is used for device discovery all available Cynap and Visualizer in the network by vSolution applications (uses Multicast IP address 239.255.255.250). If this port is blocked, vSolution applications may not be able to find devices automatically. This port is used for device discovery This port is used for control purposes e.g. room control system, and others). If this port is blocked, no control is possible This port is for secure communication between WolfVision applications (e.g. vSolution App) to Cynap and / or Visualizer. If this port is blocked, secure communication to Cynap and / or Visualizer, inclusive firmware updates are blocked. Video streams between Wolfvision App to Cynap and Visualizer. If this WolfVision GmbH Oberes Ried 14 A-6833 Klaus / AUSTRIA Tel. +43-5523-52250 Fax +43-5523-52249 E-Mail: [email protected] www.wolfvision.com port is blocked, no stream are possible. This port is for touchback between Cynap and Wolfvision App vSolution Cast to send mouse events back to the Windows computer. If this port is blocked, bidirectional inputs is not possible Touchback 50922 TCP Outbound vSolution App iOS / Android / Windows Discovery Multicast 50000 UDP Inbound This port is used for device discovery all available Cynap and Visualizer in the network by vSolution applications (uses Multicast IP address 239.255.255.250). If this port is blocked, vSolution applications may not be able to find devices automatically. http, Cynap control 80 TCP Inbound https, SSL, e.g. Cloud Service, Cynap control 443 TCP Inbound Device Discovery 50913 UDP Inbound For control purposes 50915 UDP Inbound TLS Control 50917 TCP Inbound Video streams 50921 TCP Inbound Touchback (Windows, macOS) 50922 TCP Outbound Video data stream 32768 61000 UDP Inbound /Outbound This port is used to connect to the Cynap web interface (httpd). If this port is blocked, no connection can be made. This port is used to cloud services and for secure connect to the Cynap web for secure connect to the Cynap web interface. If this port is blocked, no connection can be made. This port is used for device discovery. This port is used for device discovery. This port is for secure communication between WolfVision applications (e.g. vSolution App) to Cynap and / or Visualizer. If this port is blocked, secure communication to Cynap and / or Visualizer, inclusive firmware updates are blocked Video streams between WolfVision App to Cynap and Visualizer. If this port is blocked, no streams are possible. This port is for touchback between Cynap and WolfVision App vSolution Cast to send mouse events back to the Windows computer or MacBook. If this port is blocked, bi-directional inputs are not possible. Video data stream (e.g., BYOM, Chromecast) 16 WolfVision GmbH Oberes Ried 14 A-6833 Klaus / AUSTRIA WebRTC Tel. +43-5523-52250 Fax +43-5523-52249 E-Mail: [email protected] www.wolfvision.com TCP / UDP Outbound Communication Port WebRTC (Pexip) 10000 16000 1720 TCP Outbound TLS Control 50917 TCP Inbound WebSocket 7681 TCP Inbound WebSocket 7682 TCP Inbound This port used WebRTC service like Pexip This port is for secure communication between Wolfvision application (e.g. vSoltuion Link) t Cynap and / or Visualizer. If this port is blocked, secure communication to Cynap and / or Visualizer, inclusive firmware updates are blocked. User interface communication with Cynap (via browser) User interface communication with Cynap (via fully integrated Visualizer) vSolution Link Pro Wake On LAN 7/9 UDP DNS 53 TCP / UDP Inbound / Outbound Inbound / Outbound http, Cynap control 80 TCP Inbound https, SSL, e.g. Cloud Service, Cynap control 443 TCP Inbound SMTP 587 SMTP Outbound Discovery Multicast 50000 UDP Inbound Device Discovery 50913 UDP Inbound For control purposes 50915 TCP Inbound Zoom http 80 TCP Outbound http over TLS / SSL 443 TCP Outbound 8801 8802 3478 3479 TCP TCP UDP UDP Outbound Outbound Outbound Outbound 17 Wake On LAN – Usually port 7 is used for sending the magic packet DNS – This port will be used for Domain Name System. If this port is blocked, DNS service are not available This is the default port to connect to the web interface (httpd) of vSolution Link Pro. Of this port is blocked, connection cannot be established This is the default port to connect to web interface (https) of vSolution Link Pro. If this port is blocked, connection cannot be established. Mail Server – Port for communication with SMTP server. This port is used for device discovery all available Cynap and Visualizer in the network by vSolution applications (uses Multicast IP address 239.255.255.250). If this port is blocked, device discovery is not possible This port is used for device discovery. If this port is blocked, device discovery is not possible. This port is used for control purposes. If this port is blocked, no control is possible For Zoom clients and meeting connector For Zoom clients and meeting connector For Zoom clients For Zoom clients For Zoom clients For Zoom clients WolfVision GmbH Oberes Ried 14 A-6833 Klaus / AUSTRIA 8801 – 8810 UDP Outbound 18 Tel. +43-5523-52250 Fax +43-5523-52249 E-Mail: [email protected] www.wolfvision.com For Zoom clients WolfVision GmbH Oberes Ried 14 A-6833 Klaus / AUSTRIA Tel. +43-5523-52250 Fax +43-5523-52249 E-Mail: [email protected] www.wolfvision.com 5. Differences in Open Mode / Protected Mode When using Cynap Pure Pro, it is possible to choose between either Open or Protected Mode in Cynap settings. Modes: Open Mode The open is intended for quick and easy connections and BYOD without the need of high security and big effort for administration. When Open Mode is active, all available devices can connect to Cynap Pure Pro. Additionally, a user password cab be set. In the Open Mode, Airplay, Miracast and / or vSolution Cast PIN can be used to prevent disturbance of external devices. The PIN will be shown on the connected display only (HDMI). Protected Mode This mode allows desired mirroring sessions only, to prevent misuse and disturbances. The moderator has to enable a coming session in front by using the room management system. (The room management system needs be correctly implemented) Mirror Settings To change the security behaviour to grant or deny connection requests. To select which kind of mirroring systems could be connected. Disabled systems couldn’t share their content. Possible settings are: • Mode: Open Mode, everybody can connect. Protected Mode, every connection or mirroring has to be enabled by using the room management system. • Miracast for Android devices • AirPlay for iOS devices • Chromecast for Google Chrome • vSolution Cast 19 WolfVision GmbH Oberes Ried 14 A-6833 Klaus / AUSTRIA Tel. +43-5523-52250 Fax +43-5523-52249 E-Mail: [email protected] www.wolfvision.com 6. BYOD Cynap Pure Pro is designed to make it as easy as possible for users to connect to it. Cynap Pure Pro supports integrated mirroring protocols in its operating system. Users can connect to Cynap Pure Pro without needing any additional software. The mobile platforms are AirPlay for iOS devices and Miracast for Android and Windows devices. Regarding laptop and computer operating systems, AirPlay is also supported for Mac OS X. Windows Intel Wireless Display is also supported, and this integrates natively with Windows 8.1. AirPlay Support for iOS 5.0 (released 2011) and above, or OS X 10.8 Mountain Lion (released 2012) and above. AirPlay is transmitted via Ethernet / WLAN. It can be used for displaying up to four sources. Miracast Miracast is based on a Wi-Fi direct connection. This means that Miracast can only be used in close proximity to Cynap Pure Pro. Any used cabinet will reduce the possible transmission radius. High WLAN traffic in your environment may reduce the possible radius, increase the delay of picture transfer or results in reduced image quality (MICE support could help to increase the radius, the discovery beacon will be always sent by the dedicated built-in WLAN module. For more information, please refer to the manual. vSolution App vSolution Cast (Windows) Chromecast Screen Mirroring The vSolution App allows controlling your Cynap Pure Pro. Using our vSolution App for Android, iOS, macOS, or Windows, with a Cynap system, enables students or work colleagues to receive shared content and to control the unit. On Android, iOS and macOS, you can register your Cynap Pure Pro manually when discovering services are blocked in your network (Bonjour, mDNS). In applications where a Wi-Fi direct connection is not possible due to the installation, multiple Windows devices can be connected at the same time using the alternative vSolution Cast. Support for Chromecast capable devices. Chromecast is transmitted via Ethernet / WLAN. It can be used for displaying up to four sources. AirPlay, Chromecast, Miracast and vSolution Cast are based on device discovery technologies for maximum ease of use. Therefore it is necessary that the appropriate services (See Firewall rules) are available. Alternatively, when using vSolution Cast, a Cynap Pure Pro IP address can be entered manually. On Windows systems, vSolution Cast can either be run temporarily by users, or permanently installed (copied). The application can also be used from a USB stick without needing administrator rights, however with the restriction that no sound is transmitted. Switching Cynap Pure Pro to standby closes all connections. 20 WolfVision GmbH Oberes Ried 14 A-6833 Klaus / AUSTRIA Tel. +43-5523-52250 Fax +43-5523-52249 E-Mail: [email protected] www.wolfvision.com 7. User interface Cynap Pure Pro can be controlled using any current standard browser. The user interface has been developed using the latest web programming standards, and this means that there is no need for additional add-ons or plugins such the Java Platform, in order to have full control of Cynap Pure Pro. HTML5 technology only requires a browser that can handle JavaScript and WebSockets, and this has been state-of-the-art for the last few years. You can also adjust the settings using the remote control (optional). The remote control uses the 2.4 GHz band. The remote control has a built-in gyro sensor and can be used as a digital laser pointer. Cynap Pure Pro can also be used in combination with room management systems. Communication is possible via the Wolfprot protocol. More information about this protocol can be found in the support section of our website www.wolfvision.com . The vSolution App allows smartphones / tablets (iOS, Windows, Android) to control Cynap Pure Pro directly via WLAN. More information about the vSolution App can be found on in the support section of our website www.wolfvision.com . 21 WolfVision GmbH Oberes Ried 14 A-6833 Klaus / AUSTRIA Tel. +43-5523-52250 Fax +43-5523-52249 E-Mail: [email protected] www.wolfvision.com 8. Hardware and OS Cynap Pure Pro uses a Linux operating system. The distribution is a WolfVision specific variant, which in addition to the Linux kernel contains only the individual libraries and packages required for the functionality of Cynap Pure Pro. This operating system is efficient, secure and lean. The operating system is installed after the installation process, and every update is installed to a read-only partition that cannot be changed after the installation process. This feature and the strict separation of system and user data, such as pictures, videos etc. ensures a very high level of system security. The system structure is protected against any external access, and it does not require additional security programs (antivirus, firewall, etc.). The Cynap Pure Pro system includes all viewer and software packages, and no additional licenses are required. The current hardware specifications, connectors, delivery, and technical specifications can be found on our website www.wolfvision.com. 9. Administration Cynap Pure Pro can be managed using the vSolution Link software. With vSolution Link software, administration tasks, like firmware updates, can be performed for multiple Cynap systems simultaneously. With this tool, you can also determine the state of you Cynap Pure Pro system and sending a Wake-on-LAN (WoL) command. You can create, manage and distribute a settings profile to all Cynap systems using vSolution Link software, and you can change the background wallpaper easily. More information about vSolution Link software can be found in the support section of our website www.wolfvision.com. 22 WolfVision GmbH Oberes Ried 14 A-6833 Klaus / AUSTRIA Tel. +43-5523-52250 Fax +43-5523-52249 E-Mail: [email protected] www.wolfvision.com 10. Bandwidth Measurement Data This bandwidth measurement data has been taken using a notebook PC with a Windows operating system. The computer was connected to Cynap Pure Pro via WLAN, and was operating in network infrastructure mode. 10.1. PowerPoint Presentation Presentation with text and a few graphics are displayed from the notebook and are mirrored to Cynap Pure Pro using vSolution Cast Software to a single connected client. (Traffic Out) Max: 2,9 Mbit/s 10.2. Multimedia from Notebook to Cynap Pure Pro using vCast Software 1080p video (Big Buck Bunny) is displayed on the notebook and is mirrored using the vSolution Cast Software to a single connected client. (Traffic Out) Max: 7 Mbit/s 23 WolfVision GmbH Oberes Ried 14 A-6833 Klaus / AUSTRIA Tel. +43-5523-52250 Fax +43-5523-52249 E-Mail: [email protected] www.wolfvision.com 11. Client System Requirements Requirement Airplay Mirroring OS X Mountain Lion v10.8 (Release 2012) or later: Product iMac Mac mini MacBook Air MacBook Pro Mac Pro Version Mid 2011 or later Mid 2011 or later Mid 2011 or later Early 2011 or later Late 2013 or later Requirement Airplay Mirroring iOS 5.0 (Release 2011) or later: Product iPhone iPad iPad iPod touch Version 4 or later 2 or later mini or later 5th generation or later Requirement Miracast: Product Android Microsoft Windows Windows Phone Blackberry Version 4.4.2 or later 8.1, 10, 11 Hardware with Miracast support required 8.1, 10 10.2.1 or later Requirement Chromecast: Product Android Microsoft Windows Version 4.0.3 or later (Chromecast required) 7, 8.1, 10 (Chromecast Browser Plugin required) 24 WolfVision GmbH Oberes Ried 14 A-6833 Klaus / AUSTRIA 12. Index Version Date Changes 1.0 16.02.2021 Created 1.1 31.07.2023 - Added firewall rules - Minor text edits - Illustrations updated 1.2 18.10.2023 - Addition Firewall rules 25 Tel. +43-5523-52250 Fax +43-5523-52249 E-Mail: [email protected] www.wolfvision.com ">
/
Preuzimanje
Samo prijateljski podsetnik. Dokument možete pogledati ovde. Ali što je najvažnije, naš AI ga je već pročitao. Može da objasni složene stvari jednostavnim rečima, odgovori na vaša pitanja na bilo kom jeziku i pomogne vam da brzo navigirate čak i najdužim ili najkomplikovanijim dokumentima.
Reklama