Configuration and Image Manual
X2 HMI Panels
MAEN352B
2023-06
Foreword
This manual contains information about the image/firmware/system program (from now on referred
to as image) and how to get started with the HMI panel in the most common applications.
The information in this manual is valid for the latest versions of hardware at the time the manual was
released. All documentation is available in our Download center.
For a list of the X2 HMI panels covered in this manual, see References.
Visit Beijer Electronics SmartStore for image updates and software downloads.
Copyright © 2023 Beijer Electronics AB. All rights reserved.
The information in this document is subject to change without notice and is provided as available at the time of printing. Beijer Electronics AB reserves the right to change any information
without updating this publication. Beijer Electronics AB assumes no responsibility for any errors
that may appear in this document. All examples in this document are only intended to improve
understanding of the functionality and handling of the equipment. Beijer Electronics AB cannot
assume any liability if these examples are used in real applications. In view of the wide range
of applications for this software, users must acquire sufficient knowledge themselves in order
to ensure that it is correctly used in their specific application. Persons responsible for the
application and the equipment must themselves ensure that each application is in compliance
with all relevant requirements, standards, and legislation in respect to configuration and safety.
Beijer Electronics AB will accept no liability for any damage incurred during the installation or
use of equipment mentioned in this document. Beijer Electronics AB prohibits all modification,
changes, or conversion of the equipment.
Head Office
Beijer Electronics AB
Box 426
201 24 Malmö, Sweden
www.beijerelectronics.com / +46 40 358600
Table of Contents
1. Introduction ................................................................................................ 5
1.1. Note, Tip and Important Icons ................................................................. 5
1.2. Trademarks ........................................................................................ 5
1.3. References ......................................................................................... 5
1.4. Operating Systems ............................................................................... 7
2. General Information ...................................................................................... 8
2.1. Default IP Addresses ............................................................................. 8
2.2. Open Ports ......................................................................................... 8
3. Configuration .............................................................................................. 9
3.1. Welcome Screen .................................................................................. 9
4. Service Menu .............................................................................................. 10
4.1. Service Menu in an Empty Panel .............................................................. 10
4.2. Service Menu in a Panel Containing a Project .............................................. 10
4.3. IP Settings ........................................................................................ 10
4.4. Date/Time ........................................................................................ 11
4.5. Edit Project ...................................................................................... 12
4.6. Self Test ........................................................................................... 13
4.7. Touch Calibrate .................................................................................. 13
4.8. Debug Logging ................................................................................... 13
4.9. Diagnostic ........................................................................................ 14
5. Image and CODESYS Runtime Update ................................................................. 17
5.1. Update the Image Using USB or SD Card ..................................................... 18
5.2. Update the Image Over Ethernet ............................................................. 19
5.3. Update the Image Version Using Recovery SD Card ........................................ 20
5.4. Update the CODESYS Runtime Version Using USB or SD Card ............................. 22
5.5. Update the CODESYS Runtime Version Over Ethernet ..................................... 24
5.6. Custom Welcome Screen on X2 base v2 and extreme ..................................... 26
5.7. Custom Welcome Screen on X2 pro, marine and control .................................. 29
6. Service Warnings ......................................................................................... 31
6.1. Service Warning Suppression .................................................................. 31
7. Getting Started and Commonly Used Functions ..................................................... 33
7.1. Create and Download Project Using iX Developer .......................................... 33
7.2. Enable Diagnostics Page ........................................................................ 35
7.3. Create a Project in BCS Tools and Download the PLC Program ........................... 37
7.4. Reduce Flash Wear by Storing Data on SD Cards ........................................... 41
8. Additional Information for X2 control and SC Variants ............................................. 44
8.1. Runtime Version ................................................................................. 44
8.2. Change EtherCAT / Normal Ethernet ......................................................... 44
8.3. CODESYS License ................................................................................ 44
8.4. Load Project ..................................................................................... 44
8.5. Device Description .............................................................................. 44
Beijer Electronics, MAEN352B
3
2023-06
4
Introduction
1. Introduction
1.1. Note, Tip and Important Icons
This publication may include Important and Note icons where appropriate to point out safety-related,
or other important, information. It may also include Tips to point out useful hints to the reader. The
corresponding symbols should be interpreted as follows:
NOTE
The Note icon alerts the reader to pertinent facts and conditions.
TIP
The Tip icon indicates advice on, for example, how to design your project or how to
use a certain function.
IMPORTANT
The Important icon highlights important information.
1.2. Trademarks
Microsoft, Windows, Windows Embedded CE 6.0 R3, Windows Embedded Compact 2013, Windows 7,
Windows Embedded Standard 7 are registered trademarks or trademarks of Microsoft Corporation
in the USA and/or other countries. Any additional trade names given in this documentation are
trademarks of their corresponding owners.
1.3. References
The installation, technical data as well as cutout and outline dimensions of the panels are described
in the installation manual for each HMI panel. Please refer to the installation manuals and the iX
Developer manuals for further information.
This manual applies to the following X2 HMI panels:
• X2 base v2 (all variants)
• X2 pro (all variants)
• X2 marine (all variants)
• X2 control (all variants)
• X2 extreme (all variants)
Name
Description
MAEN361
Best Practice Image Update
MAEN328
Hardware and Installation Manual X2 base 5 v2
MAEN329
Hardware and Installation Manual X2 base 7 v2
MAEN330
Hardware and Installation Manual X2 base 7 v2 HP
Beijer Electronics, MAEN352B
5
2023-06
Introduction
Name
Description
MAEN331
Hardware and Installation Manual X2 base 10 v2
MAEN332
Hardware and Installation Manual X2 base 10 v2 HP
MAEN333
Hardware and Installation Manual X2 base 15 v2 HP
MAEN350
Hardware and Installation Manual X2 pro 4
MAEN214
Hardware and Installation Manual X2 pro 7
MAEN265
Hardware and Installation Manual X2 pro 7 2eth
MAEN220
Hardware and Installation Manual X2 pro 10
MAEN222
Hardware and Installation Manual X2 pro 12
MAEN224
Hardware and Installation Manual X2 pro 15
MAEN270
Hardware and Installation Manual X2 pro 21
MAEN216
Hardware and Installation Manual X2 marine 7
MAEN217
Hardware and Installation Manual X2 marine 7 SC
MAEN218
Hardware and Installation Manual X2 marine 7 HB
MAEN219
Hardware and Installation Manual X2 marine 7 HB SC
MAEN226
Hardware and Installation Manual X2 marine 15
MAEN227
Hardware and Installation Manual X2 marine 15 SC
MAEN228
Hardware and Installation Manual X2 marine 15 HB
MAEN229
Hardware and Installation Manual X2 marine 15 HB SC
MAEN213
Hardware and Installation Manual X2 control 4
MAEN215
Hardware and Installation Manual X2 control 7
MAEN221
Hardware and Installation Manual X2 control 10
MAEN223
Hardware and Installation Manual X2 control 12
MAEN349
Hardware and Installation Manual X2 control 15
MAEN269
Hardware and Installation Manual X2 control 21
MAEN249
Hardware and Installation Manual X2 extreme 7
MAEN250
Hardware and Installation Manual X2 extreme 7 12V
MAEN251
Hardware and Installation Manual X2 extreme 7 HP
MAEN253
Hardware and Installation Manual X2 extreme 7 SL HP
MAEN255
Hardware and Installation Manual X2 extreme 12
MAEN256
Hardware and Installation Manual X2 extreme 12 HP
MAEN258
Hardware and Installation Manual X2 extreme 12 SL HP
MAEN323
Hardware and Installation Manual X2 extreme 12 CO
MAEN339
Hardware and Installation Manual X2 extreme 12 HP web
MAEN260
Hardware and Installation Manual X2 extreme 15
MAEN261
Hardware and Installation Manual X2 extreme 15 HP
MAEN263
Hardware and Installation Manual X2 extreme 15 SL HP
MAEN310
Hardware and Installation Manual X2 extreme 15 CO
MAEN340
Hardware and Installation Manual X2 extreme 15 HP web
MAEN355
Reference Manual iX Developer
Version: 2.40 SP7 b 2.47.473 and later
2023-06
6
Beijer Electronics, MAEN352B
Introduction
Name
Description
MAEN831
Reference Manual iX Developer
Version: 2.40 SP7 b 2.47.417 and earlier
MAEN832
User's Guide iX Developer
MU299609
BCS Tools - User Manual
NOTE
For image and software updates/downloads, visit Beijer Electronics SmartStore.
Additional information, such as Start Up guides, manuals and “Best practice"
documents are available in our Download center.
NOTE
For specifications on supported USB memories and SD cards, please refer to the
Hardware and Installation manual for your specific X2 HMI panel.
1.4. Operating Systems
Image family
Operating System license included
Runtime license included
X2 base v2
X2 base v2 HP
X2 pro
X2 marine
X2 marine HB
iX Runtime
X2 extreme
X2 extreme HP
X2 extreme SL HP
X2 extreme 12V
Windows Embedded Compact 2013
Runtime (General embedded)
X2 control
iX Runtime and CODESYS
Runtime
X2 marine SC
X2 marine HB SC
X2 extreme SC
X2 extreme HP SC
X2 extreme SL HP SC
Beijer Electronics, MAEN352B
7
2023-06
General Information
2. General Information
2.1. Default IP Addresses
These are the default IP addresses for the X2 HMI panels:
Port
IP address
LAN A
192.168.1.1
LAN B (if available)
DHCP
NOTE
Devices with 2 Ethernet ports MUST NOT have IP addresses in the same subnet.
NOTE
For X2 control, and SC variants of the HMI panels:
The CODESYS runtime packages exists in two different versions: one version that sets
LAN B to be an ethernet port and LAN A to an EtherCAT port, the second version sets
LAN B to be an ethernet port and LAN A to an additional ethernet port. The default
setting is to use ethernet on both ports.
2.2. Open Ports
In the firmware there are some ports that are open by default due to the operating system or that
the internal application requires it.
Type
Description
Open by default
UDP and TCP
Project transfer (9999)
Yes
UDP
Netbios (137)
Yes
UDP
Netbios (138)
No1
1Filtered.
2023-06
8
Beijer Electronics, MAEN352B
Configuration
3. Configuration
To be able to configure the HMI panel, the following software is required:
• iX Developer to do the configuration.
• BCS Tools for X2 panels with CODESYS Runtime.
3.1. Welcome Screen
•
Apply power to the HMI panel.
Within 10–15 seconds, the welcome screen will appear (if there is no iX project on the HMI
panel).
The following items about the HMI panel are listed:
• Size of external memory card, if applicable
• IP address
• Panel image version
• CODESYS Runtime version
If a project has been downloaded to the panel, it will be loaded automatically.
If there is no project in the panel, touching the screen will display the service menu.
If there is a SD card, or USB flash drive, inserted into the panel, and the project on the SD card/USB
flash drive differs from what is saved in the HMI panel, the user is asked if the project and IP-settings
should be restored.
The Welcome screen for a X2 base 7 v2 HP.
Position
Description
1
Panel type
2
External memory card status
3
Network status. An attached network cable is indicated with an asterisk.
4
Panel image version.
Beijer Electronics, MAEN352B
9
2023-06
Service Menu
4. Service Menu
The service menu for the HMI panel can be accessed before a project is downloaded.
The service menu can only be accessed locally, not through a remote connection.
4.1. Service Menu in an Empty Panel
When no project is loaded in the panel memory, the panel will boot, displaying the welcome screen.
• Press anywhere on the panel display to enter the service menu.
4.2. Service Menu in a Panel Containing a Project
Perform the following steps to enter the service menu:
1.
Apply power to the panel.
2.
When the hourglass appears, press a finger on the screen and hold until the following message
appears on the screen: “Tap anywhere on screen or touch calibrate will start in 10 seconds.”.
3.
Press the screen once again to enter the service menu.
4.
If the service menu is password protected, you will be prompted for a pin code. Enter the pin
code.
4.3. IP Settings
The following parameters can be set:
• IP address
• Subnet mask
• Default gateway
• DNS settings for the Ethernet port on the HMI panel
The default setting for LAN A is: IP address 192.168.1.1, Subnet mask 255.255.255.0.
2023-06
10
Beijer Electronics, MAEN352B
Service Menu
If the HMI panel is equipped with two ethernet ports, then a second tab is shown in the IP settings
dialog. The default setting for LAN B is Obtain an IP address via DCHP.
NOTE
Devices with 2 Ethernet ports MUST NOT have IP addresses in the same subnet.
4.4. Date/Time
The date/time settings dialog allows setting
of the timezone, date, time and also setting
automatic adjustment of clock for daylight
saving.
Beijer Electronics, MAEN352B
11
2023-06
Service Menu
4.5. Edit Project
The edit project/restore image dialog allows
modifying the project in an HMI panel and, if
needed, restore the panel image to a previous
version.
4.5.1. Copy Project from External Memory
This option enables the function to copy an iX Developer project from an external memory, USB flash
drive or storage device connected to one of the HMI panel USB-ports.
4.5.2. Copy Project to SD Card
This option enables the function to copy the iX Developer project and all the files needed to run the
application to an external SD card.
4.5.3. Copy Project to USB Memory
The iX Developer project and all the files needed to run the application are copied to an external
USB flash drive or other USB connected storage device. Make sure that the storage device is
connected before trying this option.
4.5.4. Delete Project
The iX Developer project and all its corresponding files are deleted from the HMI panel. There is no
way of undeleting a project, make sure that the project should be deleted before confirming the
deletion.
4.5.5. Restore HMI Panel to Previous Image
The HMI panel image can be restored to the panel image version the HMI panel was using before a
new panel image was loaded into the panel. This option is used to restore a panel to a known working
condition.
2023-06
12
Beijer Electronics, MAEN352B
Service Menu
NOTE
If the operator panel contains a CODESYS Runtime, then the correct CODESYS
Runtime version (that correspond to the chosen image version) must be downloaded
to the panel after the HMI panel image version has been changed
4.5.6. Restore Panel to Factory Image
The HMI panel image can be restored to the HMI panel image version that the panel was shipped with
from the factory. Use this option if all else fails, this will downgrade the HMI panel to its initial state.
4.6. Self Test
Self tests are only carried out at Beijer Electronics service centers, additional hardware needed.
4.7. Touch Calibrate
The touch calibration screen enables the function to re-calibrate the touch screen. The re-calibration
consists of five steps, where a crosshair on the screen is pressed and held. Take care and try to do
this as precise as possible, an incorrect calibration makes it hard to use the HMI panel.
4.8. Debug Logging
The Debug Logging dialog enables the function
to enable and disable the debug logging on
the HMI panel (default setting is disable). It
also enables the function to move a previously
created set of debug log files from the HMI
panel to an USB flash drive.
Beijer Electronics, MAEN352B
13
2023-06
Service Menu
Option
Description
Enable
logging
The HMI panel will start or continue to store additional debug log information
in log files. A total of 10 log files of a maximum of 100 kB per file will be kept
in the HMI panel internal memory. If the log files are filled to the limit, the
oldest file will be overwritten first (FIFO method).
This function should only be used for a limited time, as it will continuously
write data to the flash memory and by that add to the flash memory wear.
Disable
logging
The HMI panel stops storing debug log data. The data will remain in the HMI
panel internal memory.
Move log to
USB memory
Moves the debug log files in the HMI panel to an external USB storage device.
4.9. Diagnostic
NOTE
The following information is valid for Image release 2.2 or later.
2023-06
14
Beijer Electronics, MAEN352B
Service Menu
Category
Description
ABOUT
Shows information about the use and status of the HMI panel.
OS/BOOT LOADER
INFORMATION
Shows information about Operating System and Boot Loader versions.
INTERNAL STORAGE
Shows information about the internal storage.
PANEL INFO
Shows the make, model and other information about the HMI panel.
SYSTEM BOARD
Shows the hardware information of the System board in the HMI
panel.
FRONT CARD
Shows the hardware information of the Display card in the HMI
panel.
SELFTEST
Shows the result of the last self test.
(Information only valid for Beijer Electronics service centers)
FOLDERS
Shows information about internal/external flash memory.
MEMORY
Shows information about capacity and availability for the RAM
memory.
NETWORK INTERFACES
Shows IP configurations and MAC addresses for the network adapters
in the HMI panel.
SERIAL PORTS
Shows information about the serial ports.
NOTE
The information (layout and number of screens) on the diagnostic screen pages
appear differently depending on screen size.
Beijer Electronics, MAEN352B
15
2023-06
Service Menu
4.9.1. Export Diagnostic Information
Tap Save to USB memory to export the diagnostic information to an external USB flash drive or other
USB connected storage device. Make sure that the storage device is connected before trying this
option.
2023-06
16
Beijer Electronics, MAEN352B
Image and CODESYS Runtime Update
5. Image and CODESYS Runtime Update
The HMI panel comes pre-loaded with a system image (including firmware and system program).
Images and the Image Loader utility, can be downloaded from the Firmware section in our
SmartStore.
CODESYS is available from the Software section in our SmartStore.
The image/Image Loader utility is used for:
• Updating the image by,
• creating an Image Loader SD card or USB flash drive
• transferring an image to an HMI panel through Ethernet
• Updating the CODESYS Runtime by,
• creating an auto-install package for SD card or USB flash drive
• transferring the CODESYS Runtime over Ethernet
In some occasions it is necessary to make a complete system update via Make Recovery SD card.
IMPORTANT
On an X2 pro or X2 control HMI panel with image version 2.0 b775 or older, we
recommend to update the image using Make Recovery SD Card. This means that the
iX Developer project and IP settings must be backed up from the panel before the
image is updated. See section Update the Image Version Using Recovery SD Card on
how to do the backup.
Beijer Electronics, MAEN352B
17
2023-06
Image and CODESYS Runtime Update
IMPORTANT
On an X2 extreme HMI panel with image version older than 2.0 b365, we recommend
to update the image using Make Recovery SD Card. This means that the iX
Developer project and IP settings must be backed up from the panel before the
image is updated. See section Update the Image Version Using Recovery SD Card on
how to do the backup.
To summarize, the image/CODESYS runtime can be updated in the following ways:
Update method
iX Developer project deleted by
updating
IP address reset by updating
USB
No
No
SD
No
No
Ethernet
No
No
Recovery SD card1
Yes
Yes
1Only available for image update.
On panel startup, in the welcome screen, it is possible to see the image version.
The welcome screen for an X2 pro 7 panel.
IMPORTANT
When updating the system image through “Make recovery SD card” an SD card
formatted with FAT16/FAT32 and maximum 32 GB must be used.
5.1. Update the Image Using USB or SD Card
Do the following:
1.
Download your image from Beijer Electronics SmartStore.
2.
Unzip the downloaded file and start the Image Loader application.
3.
Connect a USB flash drive or SD card to the computer.
4.
In Select drive:, choose the connected USB flash drive or SD card.
2023-06
18
Beijer Electronics, MAEN352B
Image and CODESYS Runtime Update
5.
Click Create.
6.
When finished, eject the USB flash drive or SD card.
7.
Connect the USB flash drive or SD card to the powered off unit and power it back on.
8.
Select Yes to confirm the Update.
The update is now completed.
5.2. Update the Image Over Ethernet
The Image Loader utility can be used to update the image over Ethernet.
NOTE
Before trying to update the image over Ethernet, make sure that your PC is on the
same IP-subnet as the HMI panel. If your HMI panel has an IP address of 192.168.1.1,
and a subnet mask of 255.255.255.0, then your PC must have an IP address in the
range of 192.168.1.2 – 192.168.1.254 and a subnet mask of 255.255.255.0, in order
to communicate with the HMI panel.
Do the following:
1.
Enter the panel target IP address in the dialog and click on Update to start the update.
Beijer Electronics, MAEN352B
19
2023-06
Image and CODESYS Runtime Update
2.
The dialog shows the current installed image and the new image the panel will be updated to
after the upgrade. Click on Update now! to confirm the update.
3.
A progress bar shows the update status. When the update is done, the panel will restart.
The update is now completed.
NOTE
If the HMI panel contains a CODESYS Runtime, then the CODESYS Runtime must be
transferred to the HMI panel after the image has been updated. See section Update
the CODESYS Runtime Version Using USB or SD Card or Update the CODESYS Runtime
Version Over Ethernet.
5.3. Update the Image Version Using Recovery SD Card
In a complete system update the IP settings will be reset to default values and the iX Developer
project will be deleted. To keep the IP setting and the iX Developer project it is recommended to
make a backup of the iX Developer project and make a note of the IP settings prior to an image
update.
NOTE
When updating the system image through “Make recovery SD card” an SD card
formatted with FAT16/FAT32 and maximum 32 GB must be used.
2023-06
20
Beijer Electronics, MAEN352B
Image and CODESYS Runtime Update
5.3.1. Copy iX Developer Project and IP Settings
IP settings and export of the current iX Developer project is done via the service menu.
Perform the following steps to enter the service menu:
1.
Apply power to the panel.
2.
When the hourglass appears, press a finger on the screen and hold until the following message
appears on the screen: “Tap anywhere on screen or touch calibrate will start in 10 seconds.”
3.
Tap the screen once again to enter the service menu.
4.
If the service menu is password protected, you will be prompted for a pin code. Enter the pin
code.
IP settings are found in the “IP settings” dialog. Please write down IP settings for LAN A and LAN B for
future use before proceeding.
The iX Developer project is copied in the Edit Project / Restore Image dialog.
You can choose to export the project to an SD card or USB.
1.
Connect the USB flash drive or SD card that should be used for the backup to the panel.
2.
Select Edit Project / Restore Image.
3.
Select Copy Project to SD Card or Copy Project to USB Memory.
The iX Developer project and all the files needed to run the application are copied to the SD card or
USB flash drive. Make sure that the storage device is connected before trying this option.
5.3.2. Update the Image
Do the following:
1.
Download your image from Beijer Electronics SmartStore.
2.
Unzip the downloaded file and start the Image Loader application.
3.
Connect an SD card to the computer.
4.
In Select drive:, choose the connected SD card.
Beijer Electronics, MAEN352B
21
2023-06
Image and CODESYS Runtime Update
5.
Make sure to check the Make Recovery SD card checkbox.
6.
Click Create.
7.
When finished, eject the SD card.
8.
Connect the SD card to the powered off unit and power it back on.
9.
In the dialog that opens, select Yes to confirm the Update.
The update is now completed.
NOTE
When the image is updated, the iX project and IP address can be restored again via
the service menu. The IP address is set in the IP Settings dialog, and the project is
reloaded via the menu item Edit and Copy Project from External Memory. Make sure
that the storage device is connected before proceeding with the import.
5.4. Update the CODESYS Runtime Version Using USB or SD Card
NOTE
Refer to document SUEN00392, available at Help Online, for more details and
recommendations on using the X2/BoX2 series range of products with embedded
CODESYS runtime.
To update the CODESYS Runtime, the folder containing the CODESYS .cab-files listed below must be
specified in the Image Loader utility. The existing Power Management and EtherCAT Distributed Clock
settings are shown in the Image Loader utility and can be set before updating the CODESYS Runtime.
2023-06
22
Beijer Electronics, MAEN352B
Image and CODESYS Runtime Update
Do the following:
1.
Select the folder that contains the CODESYS files.
2.
Select the desired options for Retain data and EtherCAT and click Create auto-install package.
Beijer Electronics, MAEN352B
23
2023-06
Image and CODESYS Runtime Update
NOTE
The PLC functionality has support for storing non-volatile variables. Those
variables can be stored dynamically in two different modes:
• Power-fail mode (Default setting)
If the voltage drops below a hardware given threshold (that is, during a power
loss or power dip), the system instantly copies all persistent data defined in
the PLC application from RAM into the battery backed SRAM. They are verified
and restored when the device is restarted.
• Cyclic mode
The PLC is instructed to store all retain and persistent data directly into SRAM
synchronously with every PLC cycle. This means all device types can use the
whole available memory, which is 128 kB. However, writing to the SRAM might
increase the configured PLC cycle depending on the size of used retain and
persistent data, because a SRAM is naturally slower than a RAM. This possible
increase is dependent of the application and to find out about the possible
increase one would need to monitor the configured task(s) of the project. For
projects with large amounts of persistent data, cyclic mode is recommended.
3.
Save the auto-install package to your connected USB or SD card.
4.
Eject the USB or SD card.
5.
Connect the USB flash drive or SD card to the panel and boot the panel.
6.
Answer Yes when asked if the current version of Soft PLC should be replaced.
7.
When asked if DC support for EtherCat should be installed, answering Yes or No will have the
following consequences:
• Yes: LAN A will be reserved for EtherCAT and LAN B for ethernet communication
• No: Both LAN A and LAN B can be used for ethernet communication
8.
Answer Yes when asked if Power-fail supported retain should be enabled.
9.
Eject the USB flash drive or SD card and reboot the HMI panel.
The update is now completed.
NOTE
Before downloading a new CODESYS Runtime, the HMI panel image should always
first be downloaded to the HMI panel again, even if there are no changes to the
HMI panel image. If only the CODESYS Runtime is installed, then this may result in
problems connecting to and communicating with other devices.
5.5. Update the CODESYS Runtime Version Over Ethernet
NOTE
Refer to document SUEN00392, available at Help Online, for more details and
recommendations on using the X2/BoX2 series range of products with embedded
CODESYS runtime.
2023-06
24
Beijer Electronics, MAEN352B
Image and CODESYS Runtime Update
To update the CODESYS Runtime, the folder containing the CODESYS .cab-files listed below must be
specified in the Image Loader utility. The existing Power Management and EtherCAT Distributed Clock
settings are shown in the Image Loader utility and can be set before updating the CODESYS Runtime.
Do the following:
1.
Select the folder that contains the CODESYS files.
2.
Input the Target IP address for the HMI panel.
3.
Press the Get info button to make sure that communication with the HMI panel is working.
4.
Select the desired options for Retain data and EtherCAT.
Beijer Electronics, MAEN352B
25
2023-06
Image and CODESYS Runtime Update
NOTE
The PLC functionality has support for storing non-volatile variables. Those
variables can be stored dynamically in two different modes:
• Power-fail mode (Default setting)
If the voltage drops below a hardware given threshold (that is, during a power
loss or power dip), the system instantly copies all persistent data defined in
the PLC application from RAM into the battery backed SRAM. They are verified
and restored when the device is restarted.
• Cyclic mode
The PLC is instructed to store all retain and persistent data directly into SRAM
synchronously with every PLC cycle. This means all device types can use the
whole available memory, which is 128 kB. However, writing to the SRAM might
increase the configured PLC cycle depending on the size of used retain and
persistent data, because a SRAM is naturally slower than a RAM. This possible
increase is dependent of the application and to find out about the possible
increase one would need to monitor the configured task(s) of the project. For
projects with large amounts of persistent data, cyclic mode is recommended.
5.
Press Update to perform the update.
NOTE
This button is disabled until communication has been established with the HMI
panel, by previously pressing the Get info button.
6.
Once finished, the HMI panel will automatically reboot.
The update is now completed.
NOTE
Before downloading a new CODESYS Runtime, the panel image should always first be
downloaded to the HMI panel again, even if there are no changes to the panel image.
If only the CODESYS Runtime is installed, then this may result in problems connecting
to and communicating with other devices.
5.6. Custom Welcome Screen on X2 base v2 and extreme
NOTE
Custom Welcome screen is supported on X2 base v2 and X2 pro/marine/control/
extreme.
X2 base v2 and X2 extreme support customization through the instructions described
in this chapter. The latest versions of the system programs are required.
The default image and text of the Welcome Screen on a X2 HMI panel can be replaced with a custom
image and text. The text color of the screen can also be modified or removed.
2023-06
26
Beijer Electronics, MAEN352B
Image and CODESYS Runtime Update
1.
Create a startup image with the following characteristics:
• The exact same resolution as the panel the image will be used on.
• Name: iXCustomSplash.bmp
• Image format: .bmp (bitmap)
2.
Create a configuration file for the text:
• Name: iXCustomSplash.cfg
• Parameter format: object=yes/no,RGB color in hex
• Default settings:
• Title=no,0xFFFFFF
• TerminalName=no,0xFFFFFF
• Info=yes,0xFFFFFF
• Hint=no,0xFFFFFF
• UserInfo=no,0xFFFFFF
• Parameter description:
UserInfo: Panel activity only appears during project processing.
NOTE
Panel activity only appears during project processing
• Example iXCustomSplash.cfg for above image:
Beijer Electronics, MAEN352B
27
2023-06
Image and CODESYS Runtime Update
3.
Create an iX Developer project for the panel for which you want to replace the Welcome Screen
and text.
4.
Add the image and the configuration files to the project's Project Files.
5.
Download the project to the HMI panel.
6.
Reboot the panel to load the new Welcome Screen.
TIP
To check the panel resolution, start iX Developer.
In the wizard, select the correct panel type. Check the technical data displayed for
the HMI panel. If a project already exists, simply use the toolbar and select the
Project tab, click on Settings and select Display/Target. You will find the resolution
under Screen Size.
All parameters in the configuration file are white space and case insensitive and
can be specified in any order. The last setting for a parameter always overrides the
previous.
2023-06
28
Beijer Electronics, MAEN352B
Image and CODESYS Runtime Update
5.7. Custom Welcome Screen on X2 pro, marine and control
NOTE
Custom Welcome screen is supported on X2 base v2 and X2 pro/marine/control/
extreme.
X2 pro, marine and control support customization through the instructions described
in this chapter.
The default Welcome Screen on an X2 HMI panel, with the exception of X2 base, can be replaced with
a custom picture.
1.
Create a startup image with the following characteristics:
• The exact same resolution as the panel the image will be used on.
• Name: iXCustomSplash.bmp
• Image format: .bmp (bitmap)
2.
Create an iX Developer project for the panel for which you want to replace the Welcome Screen
on.
3.
Add the image to the project's Project Files.
4.
Download the project to the HMI panel.
5.
Reboot the panel to load the new Welcome Screen.
Beijer Electronics, MAEN352B
29
2023-06
Image and CODESYS Runtime Update
TIP
To check the panel resolution, start iX Developer.
In the wizard, select the correct panel type. Check the technical data displayed for
the HMI panel. If a project already exists, simply use the toolbar and select the
Project tab, click on Settings and select Display/Target. You will find the resolution
under Screen Size.
2023-06
30
Beijer Electronics, MAEN352B
Service Warnings
6. Service Warnings
In the system image there are three types of Flash Wear Warnings:
• Rapid flash wear warning
• Message: "The internal storage memory lifetime is rapidly decreasing. Please review the online
documentation on how to reduce wear."
• Occurs when the user’s program is quickly increasing the flash memory’s wear.
• It is evaluated by every 10 % wear level.
• Flash lifetime warning (80 - 100 % wear)
• Message: "The internal storage memory is soon reaching its expected lifetime. Please review the
online documentation on how to reduce wear."
• Occurs when the internal storage memory has reached 80% of its expected lifetime.
• Flash lifetime warning (exceeded wear)
• Message: "The internal storage memory is reaching its expected lifetime. The unit should be
scheduled for maintenance service."
• Occurs when the internal storage memory has exceeded its expected lifetime.
Other warnings:
• Battery warning
• Message: "The unit internal battery is due and needs to be replaced."
• Occurs when internal battery voltage is to low to be detected.
• Image update error message
• Message: "Incorrect image CRC32! image NOT updated!"
• Occurs when image update has been aborted due to corrupt update package.
• Bootloader update error message
• Message: "Incorrect bootloader CRC32! Bootloader NOT updated!"
• Occurs when bootloader update has been aborted due to corrupt update package.
Warnings are visual 1 min after boot up and once a day at 09:00 (local time) unless suppressed.
• The service warning message can be suppressed for 30 days by checking the checkbox and pressing
OK.
• The warning message can be suppressed via settings menu in Service menu - Diagnostics Settings in the lower left corner.
• This suppression is active until next time the warning message is active. This is evaluated every
10% wear level.
6.1. Service Warning Suppression
Beijer Electronics, MAEN352B
31
2023-06
Service Warnings
A service warning may appear shortly after firmware upgrade indicating that the unit internal disk
lifetime is rapidly decreasing.
This could be due to a less efficient way of writing to flash in the previous installed firmware version.
If this happens, we recommend to suppress the warning using the following procedure.
1.
Enter service menu.
2.
Enter diagnostics.
3.
Enter settings.
4.
Suppress disk wear warning.
2023-06
32
Beijer Electronics, MAEN352B
Getting Started and Commonly Used Functions
7. Getting Started and Commonly Used Functions
7.1. Create and Download Project Using iX Developer
7.1.1. Create a Project in iX Developer
For information on creating a new project in iX Developer, see the iX Developer Reference Manual.
7.1.2. Download the iX Developer Project
To download an iX Developer project to an HMI panel, you can choose to either export the project to
a USB/SD card or to download the project over Ethernet.
Export Project to USB or SD Card
1.
Open your project in iX Developer.
2.
Select the Project tab and click Export.
3.
In the pop-up window, find and select the root folder of your USB/SD card, and save the project
there by clicking Save.
NOTE
Make sure Save as type is set to Export to folder.
4.
Eject the USB/SD card.
5.
Connect the USB/SD card to your HMI panel and boot it.
6.
Open the Service Menu, select Edit Project / Restore Image.
Beijer Electronics, MAEN352B
33
2023-06
Getting Started and Commonly Used Functions
7.
Select Copy Project from External Memory.
The installation is now completed.
Download Over Ethernet
1.
Connect the HMI panel to the PC via an Ethernet connection.
2.
Open your project in iX Developer.
3.
Select the Project tab and click Download.
4.
The Download Project dialog opens, and all devices connected in the network are listed with
information about IP address and device type.
Select your HMI panel from the list.
5.
Check that the IP address is correct and click Download.
a. Optional: Click the Include compressed project check box, to compress the project and save
it as a ZIP file.
b. Optional: Click the Password protected check box and enter a password, to protect the ZIP
file.
c. Optional: Click the Copy downloaded project to Memory card check box, to enable SD card
backup of project and settings.
2023-06
34
Beijer Electronics, MAEN352B
Getting Started and Commonly Used Functions
6.
The HMI panel responds to a download request by stopping any current project.
The installation is now completed.
7.2. Enable Diagnostics Page
The diagnostics page shows diagnostic values from the panel. The diagnostic values include internal
temperature, available RAM, used storage, connection and database errors and other system related
markers. The diagnostic page can be viewed after the project is downloaded to the panel.
In iX Developer:
1.
Open Web server configuration from System ribbon tab. Set values needed to access web server
and enable web server for the project.
NOTE
The URL for the diagnostics page should include the assigned port number.
2.
Add system tags, used on the page, manually to the project. If the system tag is missing, ‘-’ will
be displayed on the page.
NOTE
The following system tags are available:
• Communication Errors (count) (SystemTagCommunicationErrorMessage)
• Communication Error Message (SystemTagCommunicationErrorMessage)
• Database Error Active (SystemTagStorageErrorActive)
• Database Error Message (SystemTagStorageErrorMessage)
• Database Max Size Exceeded (SystemTagStorageMaxSizeExceeded)
• Current Date and Time (SystemTagDateTime)
• Debug Logging Enabled (SystemTagDebugLoggingEnabled)
3.
Select Functions - Tags - Add - Add System Tag…. Select and add needed tags in System tags
dialog.
Beijer Electronics, MAEN352B
35
2023-06
Getting Started and Commonly Used Functions
4.
Deploy by either upload files via FTP or copy into the ProjectFiles folder. Diagnostics
page files are installed with iX Developer installation and reside in ‘iX Developer 2.40
SP7\Bin\DiagnosticsPage’.
a.
Enable FTP server for the project.
i.
On the System ribbon tab (1), within the Servers group, click FTP (2).
ii.
In the dialog, check the Enable FTP server checkbox (3).
iii. (Optional) Set a username and password.
iv. Click OK.
b.
Download the project to the panel through Project - Download.
c.
Connect to the panel. Use FTP settings specified in the project with the help of any FTP
client.
d.
Create a new folder named ‘diagnostics’ in the ‘Website’ folder and copy diagnostics page
files into it.
Use this URL to access the diagnostic page: http://<image_ip_address><:port>diagnostics/index.html
to access the page. Use the port defined in the web server configuration. If Forms authentication is
2023-06
36
Beijer Electronics, MAEN352B
Getting Started and Commonly Used Functions
enabled for the web server, user is first taken through authentication process. The page is updated
asynchronously every 2 seconds with the latest data.
NOTE
For more information about how to use FTP, see Remote Access (FTP and VNC) in iX
Developer 2.xx, SUEN00314.
7.3. Create a Project in BCS Tools and Download the PLC
Program
7.3.1. Create a Project in BCS Tools
If you are using an HMI panel with a CODESYS Runtime you need to configure the HMI panel through
BCS Tools.
BCS Tools can be downloaded from Beijer Electronics SmartStore.
Once you have downloaded and opened BCS Tools, do the following to create your project:
1.
Click File > New project....
2.
Choose Standard Project.
3.
In the BCS Tools Standard Project window, click the Choose the device category: drop-down
and select the Edge Controllers group.
4.
Click the Choose the device model: drop-down and select your HMI panel from the list.
Beijer Electronics, MAEN352B
37
2023-06
Getting Started and Commonly Used Functions
NOTE
The PLC functionality has support for storing non-volatile variables. Those
variables can be stored dynamically in two different modes:
• Power-fail mode (Default setting)
If the voltage drops below a hardware given threshold (that is, during a power
loss or power dip), the system instantly copies all persistent data defined in
the PLC application from RAM into the battery backed SRAM. They are verified
and restored when the device is restarted.
• Cyclic mode
The PLC is instructed to store all retain and persistent data directly into SRAM
synchronously with every PLC cycle. This means all device types can use the
whole available memory, which is 128 kB. However, writing to the SRAM might
increase the configured PLC cycle depending on the size of used retain and
persistent data, because a SRAM is naturally slower than a RAM. This possible
increase is dependent of the application and to find out about the possible
increase one would need to monitor the configured task(s) of the project. For
projects with large amounts of persistent data, cyclic mode is recommended.
These settings must match the settings made in “Retain data options”, see
Update the CODESYS Runtime Version Using USB or SD Card or Update the
CODESYS Runtime Version Over Ethernet.
5.
Make sure that Create directory for project is checked and click Next.
6.
In the following window, choose the programming language for the POU created by the wizard,
and click Finish.
2023-06
38
Beijer Electronics, MAEN352B
Getting Started and Commonly Used Functions
7.3.2. Compile the Project
When the program is ready, a compile is needed to generate the executable code for the HMI panel.
There are two ways to compile the project, the Generate code function which is an offline compile
and the online compile, which is triggered when logging into the HMI panel if there is a code change
from the last online session.
Compile Offline
NOTE
When a program change has been made to the project, the project must be
compiled.
The offline compile is triggered by using the option Generate code from the Build menu.
The other two options, Clean/Clean all, will remove the generated application binaries and forces
BCS Tools to regenerate the application. After a Clean or Clean all, the controller must be stopped to
be able to update the application.
Beijer Electronics, MAEN352B
39
2023-06
Getting Started and Commonly Used Functions
NOTE
A project can still be changed online if the offline compile is being used, if it is only
program code changes.
Compile Online
NOTE
When a program change has been made to the project, the project must be
compiled.
This compile is triggered when logging into the CPU if there is uncompiled program code. If there are
any compile errors, the login procedure will be interrupted. The compilation must be successful to be
able to login to the CPU.
If the compilation is successful, a question of online change will be shown.
7.3.3. Download the PLC Program
There are two ways to transfer the program code to your HMI panel, the Download and the Online
Change function.
The Download function is a mode for downloading new projects and also current projects where the
PLC parameters have been changed; hardware configuration, task changes etc.
The Online Change function is a mode for downloading changes while the CPU is in RUN mode.
There is no restriction regarding how large the code change can be, as long as the only change is the
program code, the online change function is always available.
Download in STOP Mode
To download a new application or an application with hardware changes, task changes etc, the CPU
must be in STOP mode.
When logging into the CPU, BCS Tools will prompt that a download needs to be made.
When the Yes button is pressed, the CPU will enter STOP mode and the application is downloaded.
When the download is complete, BCS Tools will enter the online state with the CPU in STOP mode.
2023-06
40
Beijer Electronics, MAEN352B
Getting Started and Commonly Used Functions
To set the CPU into RUN state, press the RUN button in BCS Tools.
Online Change
The online change function is a mode for downloading changes while the CPU is in RUN state. There
is no restriction regarding how large the code change can be, if the only change is the program code.
When a change is made in the program code, BCS Tools will prompt with the following message to let
the user decide whether to make an online change or a download with the PLC in STOP mode.
When a login attempt is made and the program code differs between BCS Tools and the PLC, online
change is available.
When a change in parameters, tasks or other parameter related options are changed, no online
change can be performed. BCS Tools will prompt with a message asking if you want to perform a
download instead. Click Yes or No. Clicking Details... shows the code generation timestamp of the PC
vs the PLC.
Boot Application
The Boot Application is the program code that the CPU will load and execute, after powering on or
resetting the system.
When a download is made with the CPU in STOP mode, the downloaded project will be registered as
a Boot Application.
An online change updates the Boot Application per default.
7.4. Reduce Flash Wear by Storing Data on SD Cards
Beijer Electronics recommend using industrial SD card instead of the built-in flash memory when data
logging is performed. The capability to use external SD card for data logging on X2 HMI panels was
introduced in iX Developer 2.40 SP5. Since extensive writing to the flash memory can cause wear
problems and possibly premature failures,the alternative to write to an exchangeable SD card will
potentially lengthen the lifetime of the panel. A SD card is easy to replace compared to a built-in
memory. In addition, the memory size of the SD card is normally much larger than the built-in flash
memory.
To set up the SD card database in iX Developer:
1.
Go to Project/Settings. Select Database and select SD Card in the dialog.
Beijer Electronics, MAEN352B
41
2023-06
Getting Started and Commonly Used Functions
2.
Click on the OK Button to confirm the new settings.
When the location of the database is changed from flash to SD card (or vice versa) in an existing
application, the database will be automatically copied to the new location once the project is
transferred to the panel. This will be started immediately after the project transfer has taken place
and hence a somewhat slower project start-up time can be noticed.
It is advisable to do a backup of the database in case something happens during the database copy
operation.
If during runtime of the panel, the SD card is removed and the chosen location for the database is
the SD card, the panel will close the application and attempt to reboot until either an SD card is
reinserted into the panel, or a project is downloaded to the panel with the location set to “Hard
disk”.
Please note that if any scripting has been done towards the database, then these scripts need to be
manually adapted to work with the new location (flash or SD card).
If Audit Trail is enabled for the project and if the database is stored in SD card, the transfer client
will not provide the option to keep/remove audit trail in an existing project. It will always keep the
audit trail database. If the user wants to clear the audit trail database for the same project, the SD
card needs to be inserted into a PC and manually delete the audit trail database file.
It is also recommended to track the flash wear status in your iX Developer project.
The following System Tags can be used for that purpose:
System Tag
Description
Flash Memory Life Time
Used
The usage of the device lifetime (in percent).
Flash Memory EOL Info
Information about the flash memory end of life. The three
possible values are:
• Normal
• Warning - Consumed 80% of reserved block
• Urgent
2023-06
42
Beijer Electronics, MAEN352B
Getting Started and Commonly Used Functions
Please see document Best Practice Database on SD card or flash memory for more detailed
information.
Beijer Electronics, MAEN352B
43
2023-06
Additional Information for X2 control and SC Variants
8. Additional Information for X2 control and SC Variants
8.1. Runtime Version
The X2 control platform (including SC-versions of other X2 panels) allows the end-user to install a
CODESYS Runtime version of their choice. A number of different versions are available..
For information regarding updating the CODESYS Runtime, please see chapters Update the CODESYS
Runtime Version Using USB or SD Card and Update the CODESYS Runtime Version Over Ethernet.
8.2. Change EtherCAT / Normal Ethernet
The CODESYS runtime packages exists in two different versions: one version that sets LAN B to be an
ethernet port and LAN A to an EtherCAT port, the second version sets LAN B to be an ethernet port
and LAN A to an additional ethernet port. The default setting is to use ethernet on both ports.
If CODESYS runtime is installed with EtherCAT support, the panel image has to be reinstalled, using
the Image Loader utility, before the non-EtherCAT CODESYS runtime version can be reinstalled.
8.3. CODESYS License
8.3.1. Control License
All X2 control, X2 extreme SC and X2 marine SC HMI panels are equipped with a CODESYS Runtime
license.
8.4. Load Project
There is a hard connection between the installed CODESYS runtime version and the CODESYS PLC
project that is running on the panel. If the CODESYS runtime version is upgraded or downgraded the
PLC application must be recompiled with the correct settings for the target runtime version that is
used.
8.5. Device Description
The device description XML-file contains information that CODESYS needs in order to be able to
build projects for the CODESYS runtime. It is important that the installed device descriptor XMLfile CODESYS runtime version, matches the CODESYS runtime version used in the HMI panel. Each
available CODESYS runtime package has its corresponding XML-file. This XML device descriptor file
needs to be installed in the CODESYS development environment.
The installation button in CODESYS 3.5 SP10 Patch 1.
2023-06
44
Beijer Electronics, MAEN352B

advertisement

Key Features

  • High-resolution display
  • Powerful processor
  • Variety of I/O options
  • Supports CODESYS and iX Developer
  • Robust construction
  • Advanced features

Related manuals

Frequently Answers and Questions

What are the default IP addresses for the MAEN352B?
The default IP addresses for the MAEN352B are 192.168.0.1 and 192.168.0.10.
What are the open ports on the MAEN352B?
The open ports on the MAEN352B are TCP: 22, 80, 443, 61499 and UDP: 61499.
How do I update the image on the MAEN352B?
You can update the image on the MAEN352B using USB, SD card, or Ethernet.
How do I update the CODESYS Runtime version on the MAEN352B?
You can update the CODESYS Runtime version on the MAEN352B using USB, SD card, or Ethernet.