The ComNet™ CopperLine® Ethernet over copper line supports up to sixteen channels of 10/100Mbps Ethernet with Pass-through PoE over twisted pair cable (CAT-5, UTP), or over coaxial cable. The single channel units may be powered by a PoE switch or the included power supply. Four, eight, and sixteen channel units operate from local power. These units provide the ultimate flexibility for extending a powered device (PD) over long distance copper. DIP switches are provided for user-selection of local or remote, 10 or

100Mbps, and 1 pair or 4 pair (UTP) settings.

FEATURES

› Transmits individual Ethernet data channels with Passthrough PoE over standard UTP or Coaxial cable

› Extends Ethernet up to 3,000 feet (914 m) at 10 Mbps or

2,000 feet (610 m) at 100 Mbps over UTP cable

› Extends Ethernet up to 5,000 feet (1,524 m) at 10 Mbps or

2,000 feet (610m) at 100 Mbps over Coaxial cable

› Extended temperature operation from -40°C to +75°C

› Extended Pass-through PoE meets the IEEE 802.3af standard for Power over Ethernet

› Full 10/100 Mbps Bandwidth

› Supports Multicast, Unicast and Jumbo Frame

› Symmetric Bandwidth provides consistent upload and download with virtually zero packet loss over the total usable distance

› Type tested to RFC-2544 TCP/IP network bandwidth packet transmission standards

› User-selectable data rate for maximum bandwidth and transmission distance utilization

› Complies with all major IEEE standards and RFC network protocols for UDP, TCP/IP, HTTP/HTTPs

› Tested and certified by an independent laboratory for full compliance with the environmental requirements (ambient operating temperature, mechanical shock, vibration, humidity with condensation, high-line/low-line voltage conditions and transient voltage protection) of NEMA TS-1/TS-2 and

CALTRANS Traffic Signal Control Equipment Specifications.

› Designed and manufactured in the USA

› LED status indicators confirm operating status

› Available in small-size, ComFit interchangeable stand alone or 1RU high rack mounted models

› Lifetime warranty

APPLICATIONS

› Retrofit existing analog CCTV installations to Ethernet- based systems

› CCTV systems for casinos, airports, school campuses

LIFETIME WARRANTY WWW.COMNET.NET

TECH SUPPORT: 1.888.678.9427

CLFE(X)EO(C,U) Ethernet-over-Copper Extender With Pass-Through PoE

SPECIFICATIONS

Ethernet

Data Interface 10/100BaseT(X) Ethernet

DIP-switch selectable 10/100Mbps

Full data rate / full duplex up to the maximum rated distance

RFC 2544 TCP/IP Packet Transmission

Standards IEEE 802.3af PoE,

RFC: 768 UDP, 2068 HTTP, 793 TCP

791 IP, 1783 TFTP, 894 IP over Ethernet.

Transmission Distances 1 See chart below

Connectors

Extended Distance Coaxial (C): female BNC

Operating Power

Ethernet (U): RJ-45

Powered by PoE or 2-pin screw terminal for local power

LED Indicators Operating Power

Ethernet Link and Activity

Extended Link and Activity

Power

Pass-Through Mode 1 CH: Operates on PoE power

or optional 9 to 36 VDC or 24 VAC, 1.5 W

4 CH: 9 to 15 VDC, 5W

8 CH: 9 to 15 VDC, 10W

16 CH: 9 to 15 VDC, 20W

Mechanical

Current Protection

Circuit Board

Size (L×W×H)

Automatic Resettable Solid-State Current Limiters

Meets IPC Standard

1 CH: 3.3 × 2.5 × 1.1 in (8.4 × 6.4 × 2.8 cm)

4 CH: 6.1 × 5.3 × 1.1 in (15.5 × 13.5 × 2.8 cm)

8+ CH: 6.1 × 19 × 1.75 in (15.5

× 48.26 × 4.45 cm)

Number of Rack Slots 1 (4CH Version Only)

Shipping Weight 1 CH: <1 lbs./0.5 kg

4 CH: <2 lbs./0.9 kg

8+ CH: <5 lbs./2.3 kg

Environmental

MTBF

Operating Temp

Storage Temp

Relative Humidity

>100,000 hours

– 40˚ C to +75˚ C

UL Safety certifications conducted at maximum ambient temperatures (T ma

) of 65ºC.

– 40˚ C to +80˚ C

0% to 95% (non-condensing) 2

[1] Distance figures are based on a 50 V PSE PoE power source, and external power supplies for the extenders. Distance figures are obtained using in-house testing mirroring installations.

Factors such as coaxial and copper cable quality, the number of connectors and splices in the cable run, the use of PoE, and environmental conditions encountered within the installation might affect the actual transmission distance and should be taken into consideration. Due to advanced negotiation signaling required in IEEE802.3at applications, pass-through applications are limited to IEEE802.3af PD devices only. When using UTP models Pass-

Through PoE is only possible in 4-pair mode.

ORDERING INFORMATION

Part Number

CLFE1EOC

CLFE1EOU

Description

1 Port Ethernet-over-Coax Extender

1 Port Ethernet-over-UTP Extender

Position

Local/Remote Configurable

Channels Form Factor

1 Small Size

Local/Remote Configurable 1 Small Size

Cable

Coax

UTP

CLFE4EOC

CLFE4EOU

CLFE8EOC

CLFE8EOU

4 Port Ethernet-over-Coax Extender

4 Port Ethernet-over-UTP Extender

8 Port Ethernet-over-Coax Extender

8 Port Ethernet-over-UTP Extender

Local/Remote Configurable

Local/Remote Configurable

Local

Local

4

4

8

8

ComFit (1 Slot)

ComFit (1 Slot)

1 RU 19” Rack Mount

1 RU 19” Rack Mount

CLFE16EOC 16 Port Ethernet-over-Coax Extender Local 16 1 RU 19” Rack Mount Coax

CLFE16EOU 16 Port Ethernet-over-UTP Extender Local 16 1 RU 19” Rack Mount UTP

Accessories: Unit-appropriate power supply (one each provided with each extender unit)

Options [2] Add suffix ‘/C’ for Conformally Coated Circuit Boards to extend to condensation conditions (Extra charge, consult factory)

DIN-Rail Mounting Adaptor Kit - With Mounting Hardware (Optional, order model DINBKT1 or DINBKT4) (Suitable for 1CH and 4CH units only)

Coax

UTP

Coax

UTP

LIFETIME WARRANTY WWW.COMNET.NET

TECH SUPPORT: 1.888.678.9427

CLFE(X)EO(C,U) Ethernet-over-Copper Extender With Pass-Through PoE

MAXIMUM TRANSMISSION DISTANCES

1

Media

Data Rate 10M

COAX - RG59/U

100M 10M

UTP - 4 pair

100M 10M

UTP - 1 pair

100M

Source Power 15W 30W 15W 30W 15W 30W 15W 30W N/A

Non-PoE Max.Distance

PoE CLASS2 (6.5W)

PoE CLASS3 (13W) 1

1

1

3,000 ft

914 m

750 ft

228 m

5,000 ft

1,524 m

3,000 ft

914 m

850 ft

259 m

2,000 ft

610 m

750 ft

228 m

2,000 ft

610 m

2,000 ft

610 m

850 ft

259 m

914 m

750 ft

228 m

3,000 ft

3,000 ft

914 m

3,000 ft

914 m

850 ft

259 m

2,000 ft

2,000 ft

610 m

750 ft

228 m

610 m

2,000 ft

610 m

850 ft

259 m

3,000 ft

914 m

N/A

N/A

1,000 ft

305 m

[1] Distance figures are based on a 50 V PSE PoE power source, and external power supplies for the extenders. Distance figures are obtained using in-house testing mirroring installations.

Factors such as coaxial and copper cable quality, the number of connectors and splices in the cable run, the use of PoE, and environmental conditions encountered within the installation might affect the actual transmission distance and should be taken into consideration. Due to advanced negotiation signaling required in IEEE802.3at applications, pass-through applications are limited to IEEE802.3af PD devices only. When using UTP models Pass-Through PoE is only possible in 4-pair mode.

TYPICAL APPLICATIONS

PoE Pass-Through Mode

10 or 100 Mbps

PoE Switch

CLFE1EO(C,U)

See Chart Above

CLFE1EO(C,U)

PoE Pass-Through Mode with Multiple Remote Units

10 or 100 Mbps

PoE Switch

CLFE4EO(C,U) See Chart Above

CLFE1EO(C,U)

CLFE1EO(C,U)

CLFE1EO(C,U)

CLFE1EO(C,U)

12 VDC

Non-PoE Mode

10 or 100 Mbps

Switch

CLFE1EO(C,U)

12 VDC /

24 VAC

See Chart Above

CLFE1EO(C,U)

12 VDC /

24 VAC

PoE Camera

IP Camera

CAT-5 CABLE

TWISTED PAIR or COAX

PoE POWER

PoE Camera

PoE Camera

PoE Camera

PoE Camera

3 CORPORATE DRIVE | DANBURY, CONNECTICUT 06810 | USA | T: 203.796.5300

| F: 203.796.5303

| TECH SUPPORT: 1.888.678.9427

| [email protected]

8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE | T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | [email protected]

© 2015 Communication Networks. All Rights Reserved. “ComNet” and the “ComNet Logo” are registered trademarks of Communication Networks.

10 Feb 2015

advertisement

Related manuals

advertisement