DX100 OPTIONS
INSTRUCTIONS
FOR MANUAL BRAKE RELEASE FUNCTION
Upon receipt of the product and prior to initial operation, read these instructions thoroughly, and retain
for future reference.
MOTOMAN INSTRUCTIONS
MOTOMANINSTRUCTIONS
DX100 INSTRUCTIONS
DX100 OPERATOR’S MANUAL
DX100 MAINTENANCE MANUAL
The DX100 operator’s manuals above correspond to specific usage.
Be sure to use the appropriate manual.
Part Number: 156239-1CD
Revision: 3
YASKAWA ELECTRIC CORPORATION
MANUAL NO.
HW0485417 1
1/13
HW0485417
DX100
MANDATORY
•
This manual explains the manual brake release function of DX100.
Read this manual carefully and be sure to understand its contents
before handling the DX100.
•
General items related to safety are listed in the Section 1: Safety of
the DX100 Instructions. To ensure correct and safe operation,
carefully read the DX100 Instructions before reading this manual.
CAUTION
•
Some drawings in this manual are shown with the protective covers
or shields removed for clarity. Be sure all covers and shields are
replaced before operating this product.
•
The drawings and photos in this manual are representative
examples and differences may exist between them and the
delivered product.
•
YASKAWA may modify this model without notice when necessary
due to product improvements, modifications, or changes in
specifications. If such modification is made, the manual number will
also be revised.
•
If your copy of the manual is damaged or lost, contact a YASKAWA
representative to order a new copy. The representatives are listed
on the back cover. Be sure to tell the representative the manual
number listed on the front cover.
•
YASKAWA is not responsible for incidents arising from
unauthorized modification of its products. Unauthorized modification
voids your product’s warranty.
ii
HW0485417
2/13
HW0485417
DX100
Notes for Safe Operation
Read this manual carefully before installation, operation, maintenance, or
inspection of the DX100.
In this manual, the Notes for Safe Operation are classified as
“WARNING”, “CAUTION”, “MANDATORY”, or ”PROHIBITED”.
WARNING
CAUTION
Indicates a potentially hazardous
situation which, if not avoided, could
result in death or serious injury to
personnel.
Indicates a potentially hazardous
situation which, if not avoided, could
result in minor or moderate injury to
personnel and damage to equipment.
It may also be used to alert against
unsafe practices.
Always be sure to follow explicitly the
MANDATORY items listed under this heading.
PROHIBITED
Must never be performed.
Even items described as “CAUTION” may result in a serious accident in
some situations.
At any rate, be sure to follow these important items.
NOTE
To ensure safe and efficient operation at all times, be sure
to follow all instructions, even if not designated as “CAUTION” and “WARNING.”
iii
HW0485417
3/13
HW0485417
DX100
WARNING
•
Before operating the manipulator, check that servo power is turned
OFF when the emergency stop buttons on the front door of the
DX100 and programming pendant are pressed.
When the servo power is turned OFF, the SERVO ON LED on the
programming pendant is turned OFF.
Injury or damage to machinery may result if the emergency stop circuit
cannot stop the manipulator during an emergency. The manipulator
should not be used if the emergency stop buttons do not function.
Fig. : Emergency Stop Button
•
Once the emergency stop button is released, clear the cell of all
items which could interfere with the operation of the manipulator.
Then turn the servo power ON.
Injury may result from unintentional or unexpected manipulator motion.
Fig. : Release of Emergency Stop
TURN
•
Observe the following precautions when performing teaching
operations within P-point maximum envelope of the manipulator:
– View the manipulator from the front whenever possible.
– Always follow the predetermined operating procedure.
– Ensure that you have a safe place to retreat in case of
emergency.
Improper or unintended manipulator operation may result in injury.
•
Confirm that no person is present in the P-point maximum envelope
of the manipulator and that you are in a safe location before:
– Turning ON the DX100 power.
– Moving the manipulator with the programming pendant.
– Running the system in the check mode.
– Performing automatic operations.
•
Injury may result if anyone enters the P-point maximum envelope of
the manipulator during operation. Always press an emergency stop
button immediately if there is a problem. The emergency stop
buttons are located on the right of the front door of the DX100 and
the programming pendant.
iv
HW0485417
4/13
HW0485417
DX100
CAUTION
•
Perform the following inspection procedures prior to conducting
manipulator teaching. If problems are found, repair them
immediately, and be sure that all other necessary processing has
been performed.
– Check for problems in manipulator movement.
– Check for damage to insulation and sheathing of external wires.
•
Always return the programming pendant to the hook on the DX100
cabinet after use.
The programming pendant can be damaged if it is left in the
manipulator’s work area, on the floor, or near fixtures.
•
Read and understand the Explanation of the Warning Labels in the
DX100 Instructions before operating the manipulator.
Definition of Terms Used Often in This Manual
The MOTOMAN is the YASKAWA industrial robot product.
The MOTOMAN consists of the manipulator, the controller, the
programming pendant, and manipulator cables.
In this manual, the equipment is designated as follows.
Equipment
Manual Designation
DX100 Controller
DX100
DX100 Programming Pendant
Programming Pendant
Cable between the manipulator and
the controller
Manipulator Cable
v
HW0485417
5/13
HW0485417
DX100
Descriptions of the programming pendant, buttons, and displays are
shown as follows:
Equipment
Manual Designation
Programming Character
Pendant
Keys
The keys which have characters printed on
them are denoted with [ ].
ex. [ENTER]
Symbol
Keys
The keys which have a symbol printed on them
are not denoted with [ ] but depicted with a small
picture.
ex. page key
The cursor key is an exception, and a picture is
not shown.
Axis Keys
Number Keys
“Axis Keys” and “Number Keys” are generic
names for the keys for axis operation and
number input.
Keys pressed When two keys are to be pressed
simultaneously simultaneously, the keys are shown with a “+”
sign between them, ex. [SHIFT]+[COORD]
Displays
The menu displayed in the programming
pendant is denoted with { }.
ex. {JOB}
Description of the Operation Procedure
In the explanation of the operation procedure, the expression "Select • • • "
means that the cursor is moved to the object item and the SELECT key is
pressed, or that the item is directly selected by touching the screen.
Registered Trademark
In this manual, names of companies, corporations, or products are
trademarks, registered trademarks, or brand names for each company or
corporation. The indications of (R) and TM are omitted.
vi
HW0485417
6/13
HW0485417
DX100
Contents
1 Manual Brake Release Function..................................................................................................... 1-1
1.1 Operating Conditions of Manual Brake Release................................................................ 1-1
2 Manual Brake Release Operation................................................................................................... 2-1
3 Warning Message Display .............................................................................................................. 3-1
vii
HW0485417
7/13
HW0485417
1
1.1
DX100
1
Manual Brake Release Function
Operating Conditions of Manual Brake Release
Manual Brake Release Function
The manual brake release function allows forcible release of each motor
brakes of the manipulator and external axes by programming pendant
operation.
The following operating conditions have to be met before performing the
manual brake release function since this function releases brakes by
software, which is different from the conventional brake release by
hardware.
The manual brake release is an optional function set by parameter.
1.1
Operating Conditions of Manual Brake Release
1. DX100 Status
The DX100 has to be launched correctly*1.
2. Mode: Mode switch on the programming pendant
The function can be used in all modes: Remote / Play / Teach.
3. Security Mode
The function can be used in all modes: Operation / Editing /
Management.
4. Others
• Servo power is OFF
• Emergency stop is OFF (programming pendant, DX100, external
signals)
• Power supply unit circuit board is JANCD-YBK01-2E
If the circuit board JANCD-YBK01-1E is used for any of the axes
in the control group of manipulator, base, or station, the manual
brake release function is not available for the group with an axis
using JANCD-YBK01-1E.
1-1
HW0485417
8/13
HW0485417
DX100
1
1.1
Manual Brake Release Function
Operating Conditions of Manual Brake Release
*1 Basically, the manual brake release function is available even at alarm
occurrence.
However, the manual brake release function cannot be used if the
communication failure between each boards (YCP01, EAXA01, YIF01,
YSU01) occurs due to board failure, etc.
<Example>
The manual brake release cannot be performed at occurrence of the
alarm 1204 as shown in the following window, since the communication with the board YIF01 becomes unavailable.
In this case, reset IO modules in Maintenance mode, i.e. separate the
board, then perform the manual brake release.
Fig. 1-1: Alarm Window
If the power supply unit circuit board is JANCD-YBK01-1E and
[MANUAL BRAKE RELEASE] menu is selected, the message
"No axis for Manual Brake Release" is displayed as shown below.
Fig. 1-2: Brake Release Window
1-2
HW0485417
9/13
HW0485417
DX100
2
2
Manual Brake Release Operation
Manual Brake Release Operation
1. Select [ROBOT] under the main menu, then select [MANUAL BRAKE
RELEASE] under the submenu.
– [MANUAL BRAKE RELEASE] is shown under the submenu of the
main menu [ROBOT].
2. Select "YES".
– To avoid careless operation mistake, a warning message appears
when [MANUAL BRAKE RELEASE] menu is selected.
– Select "YES" to display [MANUAL BRAKE RELEASE] window.
– Select "NO" to return to the main menu.
2-1
HW0485417
10/13
HW0485417
DX100
2
Manual Brake Release Operation
3. Move a cursor to the axis of which the brake is to be released.
– The brake is released by following the operation: Move a cursor to
the axis of which the brake is to be released and press
[INTERLOCK] + [SELECT] while gripping Enable switch. Then the
brake status is shown.
– The brake is locked under one of the following conditions:
• When [SELECT] is released.
Also, see the following
CAUTION
• When the emergency stop button on the programming pendant,
DX100 or external device is pressed.
• When Enable switch is released or gripped further.
• When the window is switched from the Manual Brake Release window to another window.
Fig. 2-1: Manual Brake Release Window
Brake Status: : Brake locked z: Brake released
4. Press [INTERLOCK] + [SELECT] while gripping Enable switch.
CAUTION
•
Brake can be released by pressing [INTERLOCK] + [SELECT] while
gripping Enable switch.
Note that the brake remains released even though [INTERLOCK] is
released at this time.
2-2
HW0485417
11/13
HW0485417
DX100
3
3
Warning Message Display
Warning Message Display
If the manual brake release is performed under the following conditions,
the warning message appears in the message area bottom right of the
window as shown in fig. 1-2 “Brake Release Window” at page 1-2.
In this case, the brake release cannot be performed.
• Servo power is turned ON.
• Emergency stop button on the programming pendant is pressed.
• Emergency stop button on DX100 is pressed.
• External emergency stop signal is input.
3-1
HW0485417
12/13
DX100 OPTIONS
INSTRUCTIONS
FOR MANUAL BRAKE RELEASE FUNCTION
HEAD OFFICE
2-1 Kurosakishiroishi, Yahatanishi-ku, Kitakyushu 806-0004 Japan
Phone +81-93-645-7745
Fax +81-93-645-7746
YASKAWA America Inc. MOTOMAN Robotics Division
805 Liberty Lane, West Carrollton, OH 45449, U.S.A.
Phone +1-937-847-6200
Fax +1-937-847-6277
YASKAWA Nordic AB
Franska vagen 10, Box 4004, 390 04 Kalmar, Sweden
Phone +46-480-417800
Fax +46-480-417999
YASKAWA Europe GmbH Robotics Division
Kammerfeld strasse 1, 85391 Allershausen, Germany
Phone +49-8166-90-100
Fax +49-8166-90-103
YASKAWA Electric Korea Co., Ltd.
7F, Doore Bldg.; 24, Yeoido-Dong Youngdungpo-ku, Seoul, KOREA
Phone +82-2-784-7844
Fax +82-2-784-8495
YASKAWA Electric (Singapore) PTE Ltd.
151 Lorong Chuan, #04-02A, New Tech Park, Singapore 556741
Phone +65-6282-3003
Fax +65-6289-3003
YASKAWA Electric (Thailand) Co., Ltd.
252/246, 4th Floor. Muang Thai-Phatra Office Tower II Rachadaphisek Road, Huaykwang Bangkok, 10320 Thailand
Phone +66-2-693-2200
Fax +66-2-693-4200
Shougang MOTOMAN Robot Co. Ltd.
No.7, Yongchang-North Road, Beijing E&T Development Area, China 100176
Phone +86-10-6788-2858
Fax +86-10-6788-2878
MOTOMAN Motherson Robotics Ltd.
Plot No.195-196, 1st Floor, Sec.4 IMT Manesar, Gurgaon 122050, Haryana
Phone +91-124-475-8500
Fax +91-124-414-8016
Specifications are subject to change without notice
for ongoing product modifications and improvements.
C Printed in Japan November 2010 09-02
YASKAWA ELECTRIC CORPORATION
MANUAL NO.
HW0485417
1
13/13
">
/
Download
Apenas um lembrete amigável. Você pode visualizar o documento aqui mesmo. Mas o mais importante, nossa IA já o leu. Ele pode explicar coisas complexas em termos simples, responder às suas perguntas em qualquer idioma e ajudá-lo a navegar rapidamente, mesmo nos documentos mais longos ou complicados.
Anúncio