EWH 15 VE-D EWH 30 VE-D EWH 50 VE-D EWH 80 VE-D EWH 100 VE-D Volumen (L) EWH 15 VE-D EWH 30 VE-D EWH 50 VE-D EWH 80 VE-D EWH 100 VE-D 15 30 50 80 100 1500 1500 1500 1500 1500 220-240 220-240 220-240 220-240 220-240 0.75 0.75 0.75 0.75 0.75 75 75 75 75 75 Tipo I Tipo I Tipo I Tipo I Tipo I IPX4 IPX4 IPX4 IPX4 IPX4 C D A EWH 15 VE-D 384 EWH 30 VE-D 606 EWH 50 VE-D EWH 80 VE-D EWH 100 VE-D 759 791 956 340 385 450 450 C 340 340 340 385 450 200 450 D 200 200 200 200 A B (Fig.1) 2 (Fig.2) ≥1.8m (Fig.3) N (Azul) Junta triple (Fig.5) 4 Panel de control 1 2 3 4 5 55°C (Fig.6) Agua fría 9 10 Fallos Q L N E Azul Amarillo/Verde Termostato Q 0 11 Parámetro Valor k smart 0.23 0 SCF 0 CC 2.5 Qcor -0.206 kWh Qref 2.1 kWh QH2O kWh kWh Qref/QH2O 2.214 0.949 Qtest_elec 2.558 kWh T3 46.5 ℃ T5 Mact 44.6 ℃ kg 15.5 Cact 15.5 L Qelec 2.459 kWh ηwh 35.3 % AEC 522 kWh A Parámetro Valor Tset θc 45 10.6 ℃ θp 10 ℃ V40 11 L 12 ℃ Parámetro Valor k smart 0.23 1 SCF 23.2 CC 2.5 Qcor -0.081 kWh Qref 2.1 kWh Qelec,week, smart 13.233 kWh Qelec,week 14.705 kWh Qtest_elec 3.344 kWh T3 72 ℃ T5 Mact 72.9 ℃ kg Cact 30.2 L Qelec 2.92 kWh 30.2 % ηwh 38 % AEC 485 kWh A Parámetro Valor Tset 72 ℃ θc ℃ θp 10.4 70.9 V40 48 L 13 ℃ Parámetro Valor k smart 0.23 1 SCF 20.2 CC 2.5 Qcor 0.176 kWh Qref 5.845 kWh Qelec,week, smart 24.932 kWh Consumo semanal de electricidad sin controles inteligentes Q elec,week en kWh Qelec,week 26.376 kWh Qtest_elec 8.172 kWh T3 75.5 ℃ T5 Mact 74.9 ℃ kg 50.4 % Cact 50.4 L Qelec 6.939 kWh ηwh 41.7 % AEC 1232 kWh B Parámetro Valor Tset 75 ℃ θc ℃ θp 10.6 74.3 V40 88 L 14 ℃ Parámetro Valor k smart 0.23 1 SCF 31.2 CC 2.5 Qcor 0.391 kWh Qref 5.845 kWh Qelec,week, smart 24.653 kWh Consumo semanal de electricidad sin controles inteligentes Q elec,week en kWh Qelec,week 28.876 kWh Qtest_elec 8.919 kWh T3 75.2 ℃ T5 Mact 75.3 ℃ kg 80.6 % Cact 80.6 L Qelec 7.511 kWh ηwh 43.9 % AEC 1168 kWh B Parámetro Valor Tset 75 ℃ θc ℃ θp 10.3 74.2 V40 123 L 15 ℃ Parámetro Valor k smart 0.23 1 SCF 33.8 CC 2.5 Qcor 0.417 kWh Qref 5.845 kWh Qelec,week, smart 28.383 kWh Qelec,week 30.53 kWh Qtest_elec 10.962 kWh T3 75.2 ℃ T5 Mact 75.7 100.8 ℃ kg Cact 100.8 L Qelec 7.728 kWh % ηwh 44.2 % AEC 1161 kWh B Parámetro Valor Tset 75 ℃ θc ℃ θp 10.3 74.8 V40 167 L 16 ℃ 17 EWH 15 VE-D EWH 30 VE-D EWH 50 VE-D EWH 80 VE-D EWH 100 VE-D Advertência especial • • • EWH 15 VE-D EWH 30 VE-D EWH 50 VE-D EWH 80 VE-D EWH 100 VE-D 15 30 50 80 100 220-240 220-240 220-240 220-240 220-240 0.75 0.75 0.75 0.75 0.75 C D A (Fig.1) EWH 15 VE-D 384 EWH 30 VE-D 606 EWH 50 VE-D EWH 80 VE-D EWH 100 VE-D 759 791 956 340 385 450 450 C 340 340 340 385 450 200 450 D 200 200 200 200 A B ≥1.8m (Fig.3) N (Azul) 3 (Fig.4) (Fig.5) 4 Para desligar o dispositivo pressione o botão "ON / OFF", novamente. Painel de controle: 1 2 3 4 5 6 55°C Parafuso roscado Manípulo de descarga (Fig.6) 9 10 Causa E Q Q Azul Interruptor 0 Amarelo/Verde 11 N Te r m o s ta to L Parâmetro Valor Valor k Conformidade do controlo inteligente k smart 0.23 0 Fator de controlo inteligente SCF 0 CC 2.5 Qcor -0.206 kWh Qref 2.1 kWh QH2O Qref/QH2O 2.214 0.949 kWh kWh Qtest_elec 2.558 kWh T3 46.5 ℃ T5 Mact 44.6 ℃ kg Volume de armazenamento 15.5 Volume de armazenamento Cact 15.5 L Qelec 2.459 kWh ηwh 35.3 % AEC 522 kWh A Parâmetro Valor Tset θc 45 10.6 ℃ θp 10 ℃ V40 11 L 12 ℃ Parâmetro Valor k smart 0.23 1 Fator de controlo inteligente SCF 23.2 CC 2.5 Qcor -0.081 kWh Qref 2.1 kWh % Qelec,week, smart 13.233 kWh Qelec,week 14.705 kWh Qtest_elec 3.344 kWh T3 72 ℃ T5 Mact 72.9 ℃ kg Volume de armazenamento Cact 30.2 L Qelec 2.92 kWh Volume de armazenamento Eficiência energética do termoacumulador Consumo anual de eletricidade 30.2 ηwh 38 % AEC 485 kWh A Parâmetro Valor Tset 72 ℃ θc ℃ θp 10.4 70.9 V40 48 L 13 ℃ Parâmetro Valor Valor k Conformidade do controlo inteligente k smart 0.23 1 Fator de controlo inteligente SCF 20.2 Coeficiente de conversão CC 2.5 Qcor 0.176 kWh Qref 5.845 kWh % Qelec,week, smart 24.932 kWh Qelec,week 26.376 kWh Qtest_elec 8.172 kWh T3 75.5 ℃ T5 Mact 74.9 ℃ kg Volume de armazenamento 50.4 Volume de armazenamento Cact 50.4 L Qelec 6.939 kWh ηwh 41.7 % AEC 1232 kWh Classe de eficiência energética B Parâmetro Valor Tset 75 ℃ θc ℃ θp 10.6 74.3 V40 88 L 14 ℃ Valor k smart 0.23 1 Fator de controlo inteligente SCF 31.2 CC 2.5 Qcor 0.391 kWh Qref 5.845 kWh % Qelec,week, smart 24.653 kWh Qelec,week 28.876 kWh Qtest_elec 8.919 kWh T3 75.2 ℃ T5 Mact 75.3 ℃ kg Volume de armazenamento 80.6 Volume de armazenamento Cact 80.6 L Qelec 7.511 kWh ηwh 43.9 % AEC 1168 kWh B Parâmetro Valor Tset 75 ℃ θc ℃ θp 10.3 74.2 V40 123 L 15 ℃ Valor Valor k Conformidade do controlo inteligente k smart 0.23 1 Fator de controlo inteligente SCF 33.8 CC 2.5 Qcor 0.417 kWh Qref 5.845 kWh % Qelec,week, smart 28.383 kWh Qelec,week 30.53 kWh Qtest_elec 10.962 kWh T3 75.2 ℃ T5 Mact 75.7 100.8 ℃ kg Volume de armazenamento Cact 100.8 L Qelec 7.728 kWh Volume de armazenamento ηwh 44.2 % AEC 1161 kWh B Parâmetro Valor Tset 75 ℃ θc ℃ θp 10.3 74.8 V40 167 L 16 ℃ 17 EWH 15 VE-D EWH 30 VE-D EWH 50 VE-D EWH 80 VE-D EWH 100 VE-D Instruction Manual Sealed Storage Electric Water Heater EWH 15 VE-D EWH 30 VE-D EWH 50 VE-D EWH 80 VE-D EWH 100 VE-D Read the Manual before the and installing We would like to sincerely thank you for selecting our electric water heater. Please read this manual carefully before use and the methods for the installation and use of this electric water heater, to make full use of its excellent performances. WARNING • • • • • • • • • • • • Before installing this water heater, check and confirm the earth electrode on the socket is reliably grounded, without electricity. Otherwise, the electric water heater can not be installed or used. Do not use mobile sockets. Incorrect installation and use of this electric water heater may result in serious injuries to human bodies and losses of property. Performance characteristics………...………………………………… Specifications………………………………………………….………… Brief introduction of product structure……..……………...…………. Methods of installation...…………………………………….…………. Methods of use….…………………….……………………….………… Cautions…………………………..………………………………………. Maintenance……………………………………………………………… Failures and treatment…………………………………………………… Wiring diagram……………………………………………… …………… 1. Total automatic control: automatic addition o f cold water, automatic heating. 2. Three-fold safety protection: multiple safety protection devices, such as dry heating protection, extra-temperature protection, high hydraulic pressure protection, etc., safe and reliable. 3. Sapphire enamel inner container: manufactured by using advanced electrostatic dry method enamel technique, antirust, corrosion-proof, incrustation- resistant, leak-prevention, with longer lifetime. 4. Heating pipes designed with low thermal load: safe and reliable, with longer lifetime. 5. Equipped with corrosion-proof and incrustation-retardant equipment: durable products. 6. Thickened urethane integral foaming: good thermal insulation effect, energy efficient and electricity saving. 7. Imported temperature controller: accurate and reliable control of temperature. 8. Adjustable range of water temperature from 30 to 75℃. 9. Simple operation and easy use. 1 Specifications Volume (L) EWH 15 VE-D EWH 30 VE-D EWH 50 VE-D EWH 80 VE-D EWH 100 VE-D 15 30 50 80 100 Rated Power (W) 1500 1500 1500 1500 1500 Rated Voltage (ACV) 220-240 220-240 220-240 220-240 220-240 Rated Max Of Water Protection Waterproof Pressure Temperature Class Grade (MPa) (℃) I 0.75 75 IPX4 I 0.75 75 IPX4 I 0.75 75 IPX4 I 0.75 75 IPX4 I 0.75 75 IPX4 Brief introduction of product structure B C D A EWH 15 VE-D 384 EWH 30 VE-D 606 EWH 50 VE-D EWH 80 VE-D EWH 100 VE-D 759 791 956 340 385 450 450 C 340 340 340 385 450 200 450 D 200 200 200 200 A B (Fig.1) 2 Note:Please make sure to use the accessories provided by our company to install this electric water heater. This electric water heater can not be hung on the support until it has been checked that it is firm and reliable. Otherwise, the electric water heater may face from the wall, resulting in damage of the heater, even serious accidents or injuries to people. When determining the locations of the bolt holes, it shall be ensured that there is a clearance not less than 0.2m on the right side of the electric heater, to facilitate the maintenance of the heater, if necessary. 1. This electric water heater should be installed in a solid wall. If the strength of the wall can’t bear theweight equalling twice. The total weight of the heater fully filled with water, it will be necessary to install a special support. 2. After selecting a proper location, determine the positions of the two installation holes used for expansion bolts with hook (determined according to the specification of the product you select). Make two holes in the wall with the right depth by drilling the correct size matching the expansion bolts attached, insert the screws, place the hook upwards, tighten the nuts so that they are firmly fixed, and then hang the electric water heater on it (see Fig.2). (Fig.2) 3. Install the supply socket in the wall. The requirements for the socket are as follows: 250V/10A, single phase, three electrodes. It is recommended to place the socket on the right above the heater. The height from the socket to the ground shall not be less than 1.8m (see Fig.3). L (Brown) E (Yellow / Green) ≥1.8m N (Blue) 3 4. The heater can be installed, anywhere in the house not exposed to direct sunlight or rain. However, in order to reduce the pipeline heat losses, the installation position of the heater shall be closed to the location for use of water as near as possible. 1. The dimension of each pipe part is G1/2. 2. Connection of one-way safety valve:install the one-way safety valve attached with the machine at the water inlet of the main machine.(Pay attention to keep the installed drainage flexible pipes of the safety valve sloping downwards and connected with the atmosphere.) 3. In order to avoid leakage when connecting the pipelines, the rubber seal gaskets provided with the machine must be added at the end of the threads (see Fig.4). Power cord Rubber seal gaskets Rubber seal gaskets Hot water outlet Cold water inlet Pressure relief valve Pressure release hole Joint screw for cold water inlet Adjusting handle for mixing valve Hot water (Fig.4) 4. If the users want to make a multi-way supply system, refer to the method shown in Fig.5 for connection of the pipelines. 4 Power cord Pressure relief valve Triple joint Hot water outlet Cold Water inlet valve water inlet Shower nozzle Water inlet valve Water pool Mixing valve Running water pipe 1. First, open any of the outlet valves at the outlet of the water heater, then, open the inlet valve. The electric water heater begins to be filled with water. When there is water coming out of the outlet valve normally, it implies that the heater has been fully filled with water, and the outlet valve can be closed. Note: During normal operation, the inlet valve shall be set in the status of “open”. 2. Insert the supply plug into the socket, the two indicator lights will be on at the same time.. 3. This machine can automatically control the temperature. When the water temperature inside the machine has reached the set temperature (It is set to 75℃), it will be turned off automatically, and step into the status of thermal insulation; when the water temperature is decreased to a certain point, it will be turned on automatically to restore the heating, and the use of hot water will not be interrupted. When the heater is switched off automatically, the heating indicator will turn off. 5 4. Operation Of The Unit Basic Functions Of Electric Water Heaters Function Name Temperature information area ECO/SMART CONTROL function Selected temperature “ - ” Key Heating/heat preservation function Actual temperature “ + ” Key Power off memory “ECO” Key Factory default Key Name “ON/OFF” Key Automatic sleep function Anti-freeze protection Control panel(as shown) 1 2 3 4 5 ① “ON/OFF” key: Press the key; the indicator light shall be on for 2 seconds after power-on. In case of power down, the user settings will be saved by the memory function and restored once the power is on again. To switch off the system press” ON/OFF”. NOTE ● By pressing the “ON/OFF” key under any working state, the system will switch off (except in case of fault state; the indicator lights will flash and show the corresponding fault phenomenon). When the system is switched off all lights will be off. ● First time the appliance is turned on the mode ECO is activated automatically. To change the temperature, press the eco bottom to disconnect the function and then, regulate the temperature desired with "+" and "-" bottoms. 6 ② “-” key, adjust the setting temperature: The temperature can be adjusted pressing the “-“ key. Every click will reduce 10ºC the temperature setting (75-65-55-45-35). ③ “+” key, adjust the setting temperature: The temperature can be adjusted pressing the “+“key. Every click will increase 10ºC the temperature setting (35-45-55-65-75). ④ “ECO” key: a. When the unit has been switched on, press the “ECO” key to enter into the “ECO” mode. Press “-,+” key and the indicator light of actual temperature shall go out in order to highlight that the temperature is not adjustable in the “ECO” mode. The indicator light of 55ºC will flash for 5 seconds later and then the indicator light of the actual temperature will go on. Press the “ECO” key again to restore the previous temperature setting. b. Press this key for 3 seconds to enter into the SMART CONTROL mode. The pilot light indicator flash successively around temperatures when the SMART CONTROL is activated. Press SMART CONTROL bottom for 3 seconds to exit the SMART CONTROL mode and restore to the previous mode. ⑤ Temperature information area 5. Restore factory settings With the system switched off, press the “ECO” and “ON/OFF” keys for 3 seconds and the indicator lights will all go on. And then, the system shall enter into factory setting mode. 2 seconds later the system will enter into “Heating/Heat preservation function” state. See the following table for Factory setting parameters. Basic parameters of system of factory setting Fuction Factory setting parameters 55°C NOTE after entering the factory setting, press the ECO key again and the temperature is still 55ºC, because the factory setting parameter is the default 55ºC (ECO’s temperature is the same as the factory default temperature) 6. Alarm and fault self-test When a dry burning fault occurs, the 3 indicator lights 35, 55 and 75 will flash at the same time; in case of over-temperature fault, all 5 indicator lights will flash at the same time; when disconnection or short-circuit of sensor occurs, the 5 indicator lights will flash from left to right. At this time, all the relays will be disconnected and the keys will not work. After the fault is removed and the 7 power is restored, the water heater is restored to the shutdown status. In the power state, the system can be self-checking automatically. If there is a fault, the system does not work (i.e., the water heater cannot be started). ● Diagnosis of dry burning fault: When the system detects that the inner tank temperature is increasing more 15ºC/min or 8ºC/30S or more, and the temperature is higher than 50ºC, the indicator lights 35, 55 and 75 will flash to show that there is a dry burning fault. ● Diagnosis of over-temperature fault: When the inner tank temperature is over 90 degrees, it is judged to be over-temperature, and the five indicators are flashing at the same time, indicating the failure "over-temperature". ● Diagnosis of sensor fault: if the sensor is broken, all the five indicators will flash from left to right to indicate the sensor fault. 1. The supply socket must be earthed reliably. The rated current of the socket shall not be lower than 10A. The socket and plug shall be kept dry to prevent electric leakage. Inspect frequently whether the plugs are well plugged in the socket. Inspect method is as follows: insert the power supply plug into the socket,after using for half an hour, shut down the unit and pull the plug out, and inspect the plug in case it scalds your hand. If tempeature is over 50℃, please plug in another socket. to avoid the plug being damaged, fire or other personnel accidents result from badcontact. 2. For the places or the wall where the water may splash, the installation height of the socket shall not be lower than 1.8m. 3. The wall in which the electric water heater is installed shall be able to bear the weight equalling twice the weight of the heater fully filled with water without distortion or cracks. Otherwise, other strengthening measures should be adopted. 4. The one-way safety valve attached to the machine must be installed to the cold water inlet of this machine (see Fig.6). 5. For the first use (or the first use after maintenance or cleaning), the heater can not be switched on until it has been (fully) filled with water. When filling with water, at least one of the outlet valves at the outlet of the heater must be opened to release the air. This valve can be closed after the heater has been (fully) filled with water. 6. During the heating, there may be drops of water dripping from the pressure release hole of the one-way safety valve. This is a normal phenomenon. If there is a large amount of water leaking, please contact the professional maintenance personnel for repair. This pressure release hole shall, under no circumstances, be blocked; otherwise, the heater may be damaged, even resulting in safety accidents. 8 Thread screw Drain handle Pressure release hole Pressure relief valve Hot water (Fig.6) Cold water 7. The drainage pipe connected to the pressure release hole must be kept sloping downwards. 8. Since the water temperature inside the heater can reach up to 75℃, the hot water must not be exposed to people when it is initially used. Adjust the water to a reasonable tempeature to avoid scalding.. 9. In order to drain off the water inside the inner container, it can be drained off from the exit port (Twist the thread screw of the exit port), and it can also be drained off from the one-way safety valve (Twist the thread screw off the one-way safety valve, and lift the drain handle upwards). 10. If the flexible power supply cord is damaged, the special supply cord provided by the manufacturer must be used, and replaced by the professional maintenance personnel. 11. If any parts or components of this electric water heater are damaged, please contact the professional maintenance personnel for repair, and use the special spare parts and components provided by our company. 1. Check the power supply plug and socket frequently to make sure that they have good, reliable contact and are well grounded without overheating. 2. If the heater is not going to be used for a long time, especially in the regions with low temperatures (lower than 0℃), in order to prevent the heater being damaged due to the freezing of water in the inner container, the water inside the heater shall be drained away (refer to Item 9, Cautions of this manual for the method to drain away the water inside the inner container). 9 3. The recommended water hardness for an optimum working performance of the water heater should not exceed 120 mg/l of CaCo3 (Calcium Carbonate). In case of exceeding this quantity, it is recommended to use alternative decalcifying systems (You can check your local water hardness in the Water Board of you local Town Hall.) Should there be any failures due to the deposits originated by the water quality, will not be covered by the guarantee. 4. To guarantee the long-term durability and efficiency of your water heater, it is recommended to clean its inner tank and the deposits in the heating components on a regular basis. 5. It is also recommended to check the magnesium anode periodically (minimum once a year or every six months depending on the water hardness). 6. If the magnesium anode of your water tank is worn out due to the deposits originated by the water quality, the After Sales Service will have to replace it by a new one. The cost of the materials of the replacement of the magnesium anode will be covered within the guarantee period, however, the cost of the workforce or services for this replacement will not be included. 7. It is recommended to clean the surface of the water heater with soapy water, never use abrasive products or solvents. 8. During the guarantee period, the maintenance will be done by Teka´s Official After Sales Service. Any services undertaken by non-Teka Official After Sales services will be excluded from the guarantee. 10 Reasons Treatment The heating indicator light is off. Failures of the temperature controller. No water coming out of the hot water outlet. 1. The running water supply is cut off. 2. The hydraulic pressure is too low. 3. The inlet valve running water is not open. Contact with professional staff for repair. The water temperature Failures of the temperature is too high. control system. Seal problem of the joint of each pipe. Water leak E Q Q Brown Blue Contact with professional staff for repair. Seal up the joints. Switch 0 Heating indicator light N Thermostat Power supply indicator light L Thermal Cut Out 1. Wait for restoration of running water supply. 2. Use the heater again when the hydraulic pressure is increased. 3. Open the inlet valve running water. Yellow/Green 11 Heating Element Failures Produce information with EU regulation The electrical storage water heater EWH 15 VE-D of the company Teka Industrial , S.A. was tested with a declared load profile of the size “XXS” The product fulfills and corresponds to the requirements of the commission regulation standards (No 814/2013) for electrical storage water heater and achieved a water heating energy efficiency of η wh=35.3% that correspond to the water heating efficiency class “A” In accordance with AnnexⅡ Enercy Efficiency Classes article 1 of the commission regulation (No 812/2013) The evaluation of the result of this report with respect of conformity with the related commission regulation (No 812/2013 and 814/2019) is only a part of the conformity assessment to achieve the ErP-Label. Electricity consumption Qelec、water heating energy efficiency ηwh and mixed water at 40℃(V40) Description Parameter Value k smart 0.23 0 Smart control factor SCF 0 Unit Conversion coefficient CC 2.5 Ambient correction term Qcor -0.206 kWh Referenct energy Useful energy content Qref 2.1 kWh QH2O kWh kWh Correction ratio of reference and useful energy Qref/QH2O 2.214 0.949 Daily electricity consumption (measured) Qtest_elec 2.558 kWh T3 46.5 ℃ T5 Mact 44.6 ℃ kg Water temperature at the beginning of the 24h measurement cycle Water temperature at the end of the 24h measurement cycle Storage volume 15.5 Storage volume Cact 15.5 L Daily electricity consumption (corrected) Qelec 2.459 kWh Water heating energy efficiency ηwh 35.3 % Annual Electricity Consumption AEC 522 kWh Water heating energy efficiency class A Description Parameter Value Unit Water temperature without tapping Tset Average water temperature of inlet cold water θc 45 10.6 ℃ Normalised value of the average temperature Calculated volume that delivered hot water of at least 40℃ θp 10 ℃ V40 11 L 12 ℃ Description Parameter Value k smart 0.23 1 Smart control factor SCF 23.2 Unit % Conversion coefficient CC 2.5 Ambient correction term Qcor -0.081 kWh Referenct energy The weekly electricity consumption with smart controls Qelec,week,smart in kWh Qref 2.1 kWh Qelec,week, smart 13.233 kWh Qelec,week 14.705 kWh Qtest_elec 3.344 kWh T3 72 ℃ T5 Mact 72.9 ℃ kg Storage volume Cact 30.2 L Daily electricity consumption (corrected) Qelec 2.92 kWh The weekly electricity consumption without smart controls Qelec,week in kWh Daily electricity consumption (measured) Water temperature at the beginning of the 24h measurement cycle Water temperature at the end of the 24h measurement cycle Storage volume 30.2 Water heating energy efficiency ηwh 38 % Annual Electricity Consumption AEC 485 kWh Water heating energy efficiency class A Description Parameter Value Water temperature without tapping Tset 72 ℃ Average water temperature of inlet cold water θc ℃ Normalised value of the average temperature Calculated volume that delivered hot water of at least 40℃ θp 10.4 70.9 V40 48 L 13 Unit ℃ The electrical storage water heater EWH 50 VE-D of the company Teka Industrial , S.A. was tested with a declared load profile of the size “M” The product fulfills and corresponds to the requirements of the commission regulation standards (No 814/2013) for electrical storage water heater and achieved a water heating energy efficiency of η wh=41.7% that correspond to the water heating efficiency class “B” In accordance with AnnexⅡ Enercy Efficiency Classes article 1 of the commission regulation (No 812/2013) The evaluation of the result of this report with respect of conformity with the related commission regulation (No 812/2013 and 814/2019) is only a part of the conformity assessment to achieve the ErP-Label. Electricity consumption Qelec、water heating energy efficiency ηwh and mixed water at 40℃(V40) Description Parameter Value k smart 0.23 1 Smart control factor SCF 20.2 Conversion coefficient CC 2.5 Ambient correction term Qcor 0.176 kWh Referenct energy The weekly electricity consumption with smart controls Qelec,week,smart in kWh Qref 5.845 kWh Qelec,week, smart 24.932 kWh Qelec,week 26.376 kWh Qtest_elec 8.172 kWh T3 75.5 ℃ T5 Mact 74.9 ℃ kg The weekly electricity consumption without smart controls Qelec,week in kWh Daily electricity consumption (measured) Water temperature at the beginning of the 24h measurement cycle Water temperature at the end of the 24h measurement cycle Storage volume 50.4 Unit % Storage volume Cact 50.4 L Daily electricity consumption (corrected) Qelec 6.939 kWh Water heating energy efficiency ηwh 41.7 % Annual Electricity Consumption AEC 1232 kWh Water heating energy efficiency class B Description Parameter Value Water temperature without tapping Tset 75 ℃ Average water temperature of inlet cold water θc ℃ Normalised value of the average temperature Calculated volume that delivered hot water of at least 40℃ θp 10.6 74.3 V40 88 L 14 Unit ℃ The electrical storage water heater EWH 80 VE-D of the company Teka Industrial , S.A. was tested with a declared load profile of the size “M” The product fulfills and corresponds to the requirements of the commission regulation standards (No 814/2013) for electrical storage water heater and achieved a water heating energy efficiency of η wh=43.9% that correspond to the water heating efficiency class “B” In accordance with AnnexⅡ Enercy Efficiency Classes article 1 of the commission regulation (No 812/2013) The evaluation of the result of this report with respect of conformity with the related commission regulation (No 812/2013 and 814/2019) is only a part of the conformity assessment to achieve the ErP-Label. Electricity consumption Qelec、water heating energy efficiency ηwh and mixed water at 40℃(V40) Description Parameter Value k smart 0.23 1 Smart control factor SCF 31.2 Conversion coefficient CC 2.5 Ambient correction term Qcor 0.391 kWh Referenct energy The weekly electricity consumption with smart controls Qelec,week,smart in kWh Qref 5.845 kWh Qelec,week, smart 24.653 kWh Qelec,week 28.876 kWh Qtest_elec 8.919 kWh T3 75.2 ℃ T5 Mact 75.3 ℃ kg The weekly electricity consumption without smart controls Qelec,week in kWh Daily electricity consumption (measured) Water temperature at the beginning of the 24h measurement cycle Water temperature at the end of the 24h measurement cycle Storage volume 80.6 Unit % Storage volume Cact 80.6 L Daily electricity consumption (corrected) Qelec 7.511 kWh Water heating energy efficiency ηwh 43.9 % Annual Electricity Consumption AEC 1168 kWh Water heating energy efficiency class B Description Parameter Value Water temperature without tapping Tset 75 ℃ Average water temperature of inlet cold water θc ℃ Normalised value of the average temperature Calculated volume that delivered hot water of at least 40℃ θp 10.3 74.2 V40 123 L 15 Unit ℃ The electrical storage water heater EWH 100 VE-D of the company Teka Industrial , S.A. was tested with a declared load profile of the size “M” The product fulfills and corresponds to the requirements of the commission regulation standards (No 814/2013) for electrical storage water heater and achieved a water heating energy efficiency of η wh=44.2% that correspond to the water heating efficiency class “B” In accordance with AnnexⅡ Enercy Efficiency Classes article 1 of the commission regulation (No 812/2013) The evaluation of the result of this report with respect of conformity with the related commission regulation (No 812/2013 and 814/2019) is only a part of the conformity assessment to achieve the ErP-Label. Electricity consumption Qelec、water heating energy efficiency ηwh and mixed water at 40℃(V40) Description Parameter Value k smart 0.23 1 Smart control factor SCF 33.8 Conversion coefficient CC 2.5 Ambient correction term Qcor 0.417 kWh Referenct energy The weekly electricity consumption with smart controls Qelec,week,smart in kWh Qref 5.845 kWh Qelec,week, smart 28.383 kWh Qelec,week 30.53 kWh Qtest_elec 10.962 kWh T3 75.2 ℃ T5 Mact 75.7 100.8 ℃ kg Storage volume Cact 100.8 L Daily electricity consumption (corrected) Qelec 7.728 kWh The weekly electricity consumption without smart controls Qelec,week in kWh Daily electricity consumption (measured) Water temperature at the beginning of the 24h measurement cycle Water temperature at the end of the 24h measurement cycle Storage volume Unit % Water heating energy efficiency ηwh 44.2 % Annual Electricity Consumption AEC 1161 kWh Water heating energy efficiency class B Description Parameter Value Water temperature without tapping Tset 75 ℃ Average water temperature of inlet cold water θc ℃ Normalised value of the average temperature Calculated volume that delivered hot water of at least 40℃ θp 10.3 74.8 V40 167 L 16 Unit ℃ Description to ANNEX I DESCRIPTION TO ANNEX I (1)supplier’s name or trade mark (2) supplier’s model identifier (3) the declared load profile, expressed by the appropriate letter and typical usage in accordance with Table 3 of Annex VII (4) the water heating energy efficiency class of the model, determined in accordance with point 1 of Annex II (5) the water heating energy efficiency in %, rounded to the nearest integer (6) the annual electricity consumption in KWh in terms of final energy and/or the annual fuel consumption in GJ in terms of GCV, rounded to the nearest integer and calculated in accordance with point 4 of Annex VIII (7) the thermostat temperature settings of the water heater, as placed on the market (8) the daily electricity consumption Q elec in KWh, rounded to three decimal places (9) the declared load profile, expressed by the appropriate letter in accordance with Table 1 of this Annex (10) the mixed water at 40℃ V40 in litres, rounded to the nearest integer (11) maximum temperature of the thermostat (12) ‘out of the box-mode’ is the standard operating condition, setting or mode set by the manufacturer at factory level, to be active immediately after the appliance installation, suitable for normal use by the end-user according to the water tapping pattern for which the product has been designed and placed on the market (13) the water heating energy efficiency in %, rounded to one decimal place (14) All specific precautions for assembly, installation and maintenance are described in the operating and installation instructions. Read and follow the operating and installation instructions. (15) All of the data that is included in the product information was determined by applying the specifications of the relevant European directives. Differences to product information listed elsewhere may result in different test conditions. Only the data that is contained in this product information is applicable and valid. 17 Teka Country Subsidiary Austria Küppersbusch Austria Belgium Küppersbusch Belgium S.P.R.L. Bulgaria Teka Bulgaria EOOD Chile Teka Chile S.A. China Teka International Trading (Shanghai) Co. Ltd. Czech Republic Teka CZ S.R.O. Teka Ecuador S.A. Greece Teka Hellas A.E. Hungary Teka Magyarország Zrt. Indonesia PT Teka Buana Malaysia Teka Küchentechnik (Malaysia) Sdn Bhd Morocco Teka Maroc S.A. Peru Teka Küchentechnik Perú S.A. Poland Teka Polska Sp. ZO.O. Teka Portugal S.A. Romania S.C. Teka Küchentechnik Romania S.R.L. Russia/ Teka Rus LLC/ООО "Тека Рус" Singapore Teka Singapore PTE Ltd Spain Teka Industrial, S.A. Thailand Teka (Thailand) Co. Ltd. Turkey Teka Teknik Mutfak Aletleri Sanayi Ve Ukraine Teka Ukranie LLC United Arab Teka Middle East Fze Teka Küchentechnik U.A.E LLC United Arab Teka Andina S.A. TEKA Vietnam Co., Ltd. Address City Phone Eitnergasse, 13 1231 Wien Doomveld Industrie, Asse 3, No. 11 - Boite 7 1731 Zellik +32 24 668 740 Blvd. “Tsarigradsko Shosse” 135 1784 Sofia +359 29 768 330 No.1506, Shengyuan Henghua Bldg. No.200 Wending Rd. Xuhui, Dist. 200030 Shanghai +86 2 153 076 996 V Holesovickách, 593 182 00 Praha 8 - Liben +420 284 691 940 Guayaquil Thesi Roupaki - Aspropyrgos 193 00 Athens Terv u. 92 9200 Mosonmagyaróvár Jalan Menteng Raya, Kantor Taman A9 Unit A3 12950 Jakarta +43 18 668 022 + 56 24 386 000 +593 42 100 311 +30 2 109 760 283 +36 96 574 500 +62 215 762 272 10 Jalan Kartunis U1/47, Temasya Park, Off Glenmarie 40150 Shah Alam, Selangor Darul Ehsan Blvd Manuel A. Camacho 126, Piso 3 Col. Chapultepec 73, Bd. Slimane, Depôt 33, Route de Ain Sebaa Lima ul. 3-go Maja 8 / A2 05-800 Pruszkow Sevastopol str., no 24, 5th floor, of. 15 010992 Bucharest Sector 1 +40 212 334 450 Neverovskogo 9, Office 417, 121170, Moscow, Russia 121087 Россия, Москва +7 4 956 450 064 Clemenceau Avenue, 83, 01-33/34 UE Square 239920 Singapore C/ Cajo,17 39011 Santander +60 376 201 600 +52 5 551 330 493 +212 22 674 462 +51 14 363 078 +48 227 383 270 +35 1 234 329 500 +65 67 342 415 +34 942 355 050 364/8 Sri-Ayuttaya Road, Phayathai, Ratchatavee 10400 Bangkok Büyükdere Cad. 24/13 80290 Mecidiyeköy, Istanbul +90 2 122 883 134 86-e, Bozhenko Str .2nd floor,4th entrance 03150 Kyiv +380 444 960 680 Building LOB 16, Office 417 +971 48 872 912 Bin Khedia Centre +971 42 833 047 803, Fl 8th, Daiminh Convention Center, 77, Hoang Van Thai, Tan Phu Ward, District 7, Ho Chi Minh +66 -26 424 888 +58 2 122 912 821 +84 854 160 646 Venezuela Vietnam www.teka.com “for further information and updated contact adresses, please refer to the corporate website”
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement