Honeywell Home TrueZONE ARD Series 설치 설명서
Honeywell Home TrueZONE ARD Series is a powerful and versatile damper assembly designed to provide precise airflow control in your home's ductwork. It features adjustable range stops for customized airflow settings, allowing you to optimize comfort and efficiency in each room. Installation is simple, with the ability to mount the actuator on the side or top of the damper to prevent condensation issues. Whether you're looking to improve temperature control, save energy, or enhance overall home comfort, the TrueZONE ARD Series is an excellent choice.
PDF
문서
광고
광고
TrueZONE ARD, EARD, and ZD Series Damper Assemblies INSTALLATION INSTRUCTIONS For Full Installation Instructions Visit www.forwardthinking.honeywellhome.com to download installation instructions and learn more about TrueZONE products. INSTALLATION 1. Unpack the damper and install into ductwork. NOTE: For insulated duct, slide the insulation under the actuator and tape it to the actuator’s outside flange to seal. NOTE: In unconditioned spaces, mount the actuator only on the side or top of the damper. Mounting on the bottom of the damper may result in condensation dripping into the actuator. 2. Set the range stop to the desired position. Position 0 means fully closed. NOTE: On ARD/ZD models, range stops prevent full closure. On EARD model, range stop prevents full open. Table 1. Approximate ARD/ZD Bleed Rate. Position Bleed Rate 3. 0 Closed 1 16% 2 30% 3 50% Wire the actuator. See “Typical Wiring Examples” on page 2. a. For 2 wire usage, wire M1 and M6. See Fig. 1. b. For 3 wire usage, break the plastic tab to access M4. See Fig. 2. c. For EARD wiring, use only 2 VENT terminals. See Fig. 4 33-00079EFS-07 TRUEZONE ARD, EARD, AND ZD SERIES DAMPER ASSEMBLIES Field Converting ARD Damper from Normally Open to Normally Closed NOTE: To have the lights and position indicator be accurate, you would need to replace the M847D-ZONE actuator with the M847DVENT actuator. If this is installed in an attic or crawlspace which is not visible to the customer, and having the lights and indicator be reversed is not a concern to you, the M847DZONE actuator can be used. The EARD dampers come from the factory as spring-closed/ power-open dampers. 1. 2. 3. 4. Remove the actuator. Locate the two plastic grommets on the damper and move them from one side to other. Rotate the damper to closed position. Replace the actuator on the opposite side of the damper. Typical Wiring Examples TrueZONE DAMPERS TO HZ432 ZONE PANEL EIM M1 COMMON ZONE 1 DAMPER M1 M4 M6 R M6 CLOSED CONV M35493 POWER HEAT COOL FAN U1 U2 U3 Fig. 1. 2-Wire Operation (Red LED only). TrueZONE DAMPERS TO HZ432 ZONE PANEL M1 COMMON ZONE 1 DAMPER M1 M4 M6 R TO THERMOSTAT FURNACE C R W W2 Y A Y2 G M4 GREEN LED M6 CLOSED M35494 VENT EARD Fig. 2. 3-Wire Operation (Red and Green LEDs). VENT NOTE: 2- and 3-wire operation are Power Close/ Spring Open. Additional wire only adds green LED. A B C D C R THERMOSTAT SYSTEM TRANSFORMER 24 VAC S4 S4 120 VAC S3 S3 M35495 C K RC EXTERNAL TRANSFORMER R 24 VAC Fig. 4. Wiring an EARD fresh air damper to a THM5421R EIM controlled by either Prestige or RedLINK VisionPRO thermostat. U1 U1 DAMPER M1 M6 M35633 Fig. 3. EARD fresh air Damper with external transformer. 33-00079EFS—07 SENSORS 2 INSTALLATION 1. 3. 0 Fermé 1 16 % 2 30 % 3 50 % ? 33-00079EFS-07 ENSEMBLES DE REGISTRE TRUEZONE SÉRIES ARD, EARD ET ZD EIM M1 COMMUN ZONE 1 DAMPER M1 M4 M6 R VERS THERMOSTAT M6 FERMÉ CONV MF35493 POWER HEAT COOL FAN U1 U2 U3 APPAREIL DE CHAUFFAGE C R W W2 Y A Y2 G M1 COMMUN ZONE 1 DAMPER M1 M4 M6 R M4 DEL VERTE M6 FERMÉ VENT. MF35494 EARD VENT. A B C D S4 S4 S3 S3 C R THERMOSTAT TRANSFORMATEUR DU SYSTÈME 24 V c.a. MF35495 120 V c.a. C K RC TRANSFORMATEUR EXTERNE R 24 V c.a. U1 U1 REGISTRE M1 M6 MF35633 CAPTEURS 4 INSTALACIÓN 1. 2. NOTA: 3. Índice de purga 0 Cerrado 1 16% 2 30% 3 50% 33-00079EFS-07 ENSAMBLES DE REGULADORES TRUEZONE DE LAS SERIES ARD, EARD Y ZD 1. 2. 3. 4. Ejemplos típicos de cableado REGULADORES TrueZONE A PANEL DE ZONA HZ432 EIM M1 COMÚN ZONE 1 DAMPER M1 M4 M6 R AL TERMOSTATO M6 CERRADO CONV POWER HEAT COOL FAN U1 U2 U3 MS35493 SISTEMA DE CALEFACCIÓN C R W W2 Y A REGULADORES TrueZONE A PANEL DE ZONA HZ432 Y2 G M1 COMÚN ZONE 1 DAMPER M1 M4 M6 R M4 VERDE M6 CERRADO VENTILACIÓN EARD MS35494 VENTILACIÓN A B C C R TERMOSTATO D S4 S4 TRANSFORMADOR DEL SISTEMA 24 V CA S3 S3 MS35495 120 V CA C K RC TRANSFORMADOR EXTERNO R 24 V CA U1 U1 REGULADOR M1 M6 MS35633 Fig. 3. Amortiguador EARD de aire fresco con transformador externo. 33-00079EFS—07 SENSORES 6 ENSAMBLES DE REGULADORES TRUEZONE DE LAS SERIES ARD, EARD Y ZD NOTES / REMARQUES / NOTAS 7 33-00079EFS—07 ENSAMBLES DE REGULADORES TRUEZONE DE LAS SERIES ARD, EARD Y ZD Resideo Inc., 1985 Douglas Drive North, Golden Valley, MN 55422 www.resideo.com 33-00079EFS—07 M.S. Rev. 11-19 | Printed in United States This product is manufactured by Resideo Technologies, Inc., Golden Valley, MN, 1-800-468-1502 ©2019 Resideo Technologies, Inc. The Honeywell Home trademark is used under license from Honeywell International Inc. All rights reserved.">
/
다운로드
친절한 알림입니다. 여기에서 문서를 볼 수 있습니다. 그러나 가장 중요한 것은 AI가 이미 읽었다는 것입니다. 복잡한 내용을 간단하게 설명하고, 모든 언어로 질문에 답변하고, 가장 길거나 복잡한 문서도 빠르게 탐색할 수 있도록 도와줍니다.
광고