For Full Installation Instructions. Honeywell Home TrueZONE ARD Series
Honeywell Home TrueZONE ARD Series is a powerful and versatile damper assembly designed to provide precise airflow control in your home's ductwork. It features adjustable range stops for customized airflow settings, allowing you to optimize comfort and efficiency in each room. Installation is simple, with the ability to mount the actuator on the side or top of the damper to prevent condensation issues. Whether you're looking to improve temperature control, save energy, or enhance overall home comfort, the TrueZONE ARD Series is an excellent choice.
Advertisement
Advertisement
TrueZONE ARD, EARD, and ZD
Series Damper Assemblies
For Full Installation Instructions
Visit www.forwardthinking.honeywellhome.com to download installation instructions and learn more about TrueZONE products.
INSTALLATION
1.
Unpack the damper and install into ductwork.
NOTE: For insulated duct, slide the insulation under the actuator and tape it to the actuator’s outside flange to seal.
NOTE: In unconditioned spaces, mount the actuator only on the side or top of the damper. Mounting on the bottom of the damper may result in condensation dripping into the actuator.
2.
Set the range stop to the desired position.
Position 0 means fully closed.
NOTE: On ARD/ZD models, range stops prevent full closure. On EARD model, range stop prevents full open.
Table 1. Approximate ARD/ZD Bleed Rate.
Position Bleed Rate
0 Closed
1
2
16%
30%
3 50%
3.
Wire the actuator. See “Typical Wiring Examples” on page 2.
a. For 2 wire usage, wire M1 and M6. See Fig. 1.
b. For 3 wire usage, break the plastic tab to
c. For EARD wiring, use only 2 VENT terminals.
INSTALLATION INSTRUCTIONS
33-00079EFS-07
TRUEZONE ARD, EARD, AND ZD SERIES DAMPER ASSEMBLIES
Field Converting ARD Damper from Normally Open to Normally
Closed
NOTE: To have the lights and position indicator be accurate, you would need to replace the
M847D-ZONE actuator with the M847D-
VENT actuator. If this is installed in an attic or crawlspace which is not visible to the customer, and having the lights and indicator be reversed is not a concern to you, the M847D-
ZONE actuator can be used. The EARD dampers come from the factory as spring-closed/ power-open dampers.
1.
Remove the actuator.
2.
Locate the two plastic grommets on the damper and move them from one side to other.
3.
Rotate the damper to closed position.
4.
Replace the actuator on the opposite side of the damper.
Typical Wiring Examples
TrueZONE DAMPERS TO HZ432 ZONE PANEL
M1 COMMON
M1
M4
M6
R
M6 CLOSED
M35493
Fig. 1. 2-Wire Operation (Red LED only).
C
R
SYSTEM
TRANSFORMER
24
VAC
THERMOSTAT
C
K
R
C
R
U1
U1
M1
DAMPER
M6
EXTERNAL
TRANSFORMER
24
VAC
M35633
Fig. 3. EARD fresh air Damper with external transformer.
EIM
POWER
HEAT
COOL
FAN
U1
U2
U3
TO THERMOSTAT
CONV
FURNACE
Y
Y2
G
C
R
W
W2
TrueZONE DAMPERS TO HZ432 ZONE PANEL
M1
M4
M6
R
M1 COMMON
M4 GREEN LED
M6 CLOSED
M35494
Fig. 2. 3-Wire Operation (Red and Green LEDs).
NOTE: 2- and 3-wire operation are Power Close/
Spring Open. Additional wire only adds green
LED.
A
VENT
EARD
VENT
A
B
C
D
S4
S4
S3
S3
SENSORS
M35495
Fig. 4. Wiring an EARD fresh air damper to a
THM5421R EIM controlled by either Prestige or
RedLINK VisionPRO thermostat.
33-00079EFS—07 2