6.3 Main User Interface Elements
After starting the software an user interface opens in the
Scanning Mode
to identify and show the connected hardware and includes different options (button, menu bar, dropdown menu) to change the parameters of the measurement
(Configuration
)
10
, to select the output options (
Diagram
) and to control the next program steps (
Measurement, Calibration
).
Configuration (Sensor settings):
The most important parameters can be changed directly by the user. It is possible to initialize and control the measurements. After activating via pressing the ‘Start’ button the test software begins with the measurements. Measurements will be performed sequentially in continuous mode. By selecting parameters such as Integration Time, Divider or
Amplification, the sensor system can be directly controlled by the user.
Detect optimal sensor settings:
The functions
GET PWM period
and
Detect settings
supports the process of finding parameter settings based on automatically performed measurements.
Get PWM period:
is an optional function
11
of the C3 for frequency detection & flicker
(frequency not amplitudes shifting) compensation for monitors or displays which operate with specific background PWM frequencies. A Fourier transformation algorithm is utilized to determine these effects and analyzes the measurement frequency in relation to the displayspecific PWM. The result is the potential detection of a dominant frequency and compensation recommendation. The analysis is performed at a 2000 Hertz detection frequency. The settings of
IntegrationCounter
, reference current and divider are ignored during this detection procedure.
Detect settings:
This function automatically performs measurements to find the specification for
Reference Current
and
Integration Counter
based on the given
SynPeriod.
So the ratio between signal and noise (maximum of digits) can be optimized
.
10
Please note different units of measurements depend on software alternatives and optional functions.
11
If a grey button for that function is active then this function was not activated. Please contact our sales team if you have an interest to use this function.
ams User Guide
[v1-00] 2017-Jul-11
Page 11
Document Feedback
AS73210-AS89010-C3 SET DK
Development Kit with USB interface
Figure 6: Main User interface elements
Overview sensor configuration:
Print all specified parameters for the connected sensors in a matrix and is the basic window to check or edit the sensor calibration matrix and dark values.
Measurement:
Gives the option to modify the behavior during a measurement such as delay or the color space of the connected device. Additionally, the measurement can be started or stopped here
Sensor:
Select the form how the sensor results should be shown and define a
Delay
time between single measurements. Note,
Delay
will be set also automatically by the software based on the specified
Integration Time
. This time cannot be defined smaller.
Spectrometer:
Configures an optional spectrometer device for additional measurements by such a device. This one can be used as a reference to compare the measurement results
that are taken by the sensor and optimize calibration procedures (see 0).
Delta values & plot:
Allows to compare the measurement values to
Reference
values that can be selected. Furthermore, the delta plot can be activated or deactivated. If only one Sensor is connected or more than one device (sensor, spectrometer) with different numbers of measurements is selected, the delta function is disabled or will be stopped by an error.
ams User Guide
[v1-00] 2017-Jul-11
Page 12
Document Feedback