2.6.2.5 Entering Character Data
This method is used for parameters requiring alphanumeric character entry, such as for entering tags, etc.
General Menu Notes:
Push button
Up
Down
Back
Enter
Keystroke Action
Moves to the previous character (Z...Y...X...W).
If held down, the characters scroll until the push button is released.
Moves to the next item character (A...B...C...D).
If held down, the characters scroll until the push button is released.
Moves the cursor back to the left. If the cursor is already at the leftmost position, then the screen is exited without changing the original tag characters.
Moves the cursor forward to the right. If the cursor is at the rightmost position, then the new tag is saved.
2.6.3 Password Protection
The PULSAR Model R96 transmitter has three levels of password protection to restrict access to certain portions of the menu structure that affect the operation of the system.
The user password can be changed to any numerical value up to 59999. When the transmitter is programmed for password protection, a password is required whenever configuration values are changed.
User Password
The User Password allows the customer to limit access to the basic configuration parameters.
The default User Password installed in the transmitter at the factory is 0. With a password of 0, the transmitter is no longer password protected and any value in the basic user menus can be adjusted without entering a confirming password.
NOTE: If a User Password is not known or has been misplaced, the menu item New Password in the DEVICE SETUP/ADVANCED
CONFIG menu displays an encrypted value representing the present password. Contact Technical Support with this encrypted password to retrieve the original User Password.
58-602 Pulsar
®
Model R96 Radar Transmitter
advertisement
Related manuals
advertisement
Table of contents
- 5 1.1 Getting Started
- 5 1.1.1 Equipment and Tools
- 6 1.1.2 Configuration Information
- 7 1.2 QuickStart Mounting
- 7 1.2.1 Antenna
- 7 1.2.2 Transmitter
- 8 1.3 QuickStart Wiring
- 8 1.4 QuickStart Configuration
- 10 1.4.1 QuickStart Menu Options
- 11 1.4.1.1 QuickStart Numerical Data Entry
- 12 2.1 Unpacking
- 13 2.3 Before You Begin
- 13 2.3.1 Site Preparation
- 13 2.3.2 Equipment and Tools
- 13 2.3.3 Operational Considerations
- 14 2.3.3.1 Maximum Distance
- 14 2.3.3.2 Minimum Distance
- 14 GWR Alternative
- 15 2.4 Mounting
- 15 2.4.1 Installing the Antenna
- 15 2.4.1.1 Location
- 15 2.4.1.2 Beam Angle
- 16 2.4.1.3 Obstructions
- 16 2.4.1.4 Nozzles
- 17 2.4.1.5 Standpipes and Stillwells
- 17 2.4.2 Installing the Transmitter
- 17 2.4.2.1 Orientation
- 18 2.4.2.2 Initial Installation
- 18 2.4.2.3 Low Echo Margin
- 19 2.5 Wiring
- 19 2.5.1 General Purpose or Non-Incendive
- 20 2.5.2 Intrinsically Safe
- 20 2.5.3 Explosion Proof
- 21 2.6 Configuring the Transmitter
- 21 2.6.1 Bench Configuration
- 22 2.6.2 Menu Traversal and Data Entry
- 22 2.6.2.1 Navigating the Menu
- 22 2.6.2.2 Data Selection
- 23 Digit Entry
- 23 Increment/Decrement
- 24 2.6.2.5 Entering Character Data
- 24 2.6.3 Password Protection
- 25 2.6.4 Menu: Step-By-Step Procedure
- 28 2.6.5 Configuration Menu: Device Setup
- 33 2.7.1 Connections
- 33 2.7.2 Display Menu
- 33 2.7.3 HART Revision Table
- 33 2.7.3.1 Model R
- 34 2.7.4 HART Menu
- 36 3.1 Description
- 36 3.2 Theory of Operation
- 36 3.2.1 Pulse Burst Radar
- 37 3.2.2 Equivalent Time Sampling
- 37 3.3 Configuration Information
- 37 3.3.1 Bottom Blocking Distance Description
- 39 3.3.2 Echo Rejection
- 39 3.3.3 Volumetric Capability
- 39 Vessel Types
- 41 3.3.3.2 Configuration Using Custom Table
- 41 3.3.4 Reset Function
- 42 3.4 Troubleshooting and Diagnostics
- 42 3.4.1 Diagnostics (Namur NE 107)
- 44 3.4.2 Diagnostic Indication Simulation
- 44 3.4.3 Diagnostic Help
- 46 3.4.4 Diagnostic Indicator Table
- 48 Shooting Capabilities
- 48 3.4.5.1 Echo History Setup
- 48 3.4.5.2 Event History
- 48 3.4.5.3 Context-sensitive Help
- 48 3.4.5.2 Trend Data
- 49 3.5 Agency Approvals
- 50 3.5.1 Agency Drawing & Entity Parameters
- 52 3.6 Replacement Parts
- 53 3.7 Specifications
- 53 3.7.1 Functional – Transmitter
- 54 3.7.2 Functional – Environmental
- 55 3.7.2.1 Safe Operating Area
- 55 3.7.2.2 Supply Voltage
- 55 3.7.3 O-ring (seal) Selection Chart
- 56 3.7.4 Functional – Antenna
- 56 Pressure/Temperature Rings
- 57 3.7.6 Physical
- 58 3.8 Model Numbers
- 58 3.8.1 PULSAR Model R96 Radar Transmitter
- 59 3.8.2 Radar Antennas – Dielectric Rod
- 60 3.8.3 Radar Antennas – Horn
- 61 4.1 Echo Rejection