- Home
- Domestic appliances
- Large home appliances
- Cookers
- KitchenAid
- KFEG500EBS
- Installation instructions
Level Range. Whirlpool KSGB900ESS, WFE975H0HV, KSEB900ESS, W10665256D, KSGG700EWH, KFID500ESS, KFGC500JYP, KFGC506JSS, KFED500ESS, WFE775H0HZ
Add to my manuals
48 Pages
advertisement
Level Range
1. Place level on the oven bottom, as indicated in one of the two figures below, depending on the size of the level. Check with the level side to side and front to back.
3. Use a
¹⁵⁄₁₆
" (2.4 cm) combination wrench and an adjustable wrench to attach the flexible connector to the adapters.
IMPORTANT: All connections must be wrench-tightened. Do not make connections to the gas regulator too tight. Making the connections too tight may crack the regulator and cause a gas leak. Do not allow the regulator to turn when tightening fittings.
A
B
C
D
E
2. If range is not level, use a wrench or pliers to adjust leveling legs up or down until the range is level.
NOTE: Range must be level for satisfactory baking performance and best cleaning results using AquaLift ®
Self-Clean Technology.
Make Gas Connection
WARNING
A. Gas pressure regulator
B. Use pipe-joint compound.
C. Adapter (must have ½"
[1.3 cm] male pipe thread)
D. Flexible connector
H
G F
E. Manual gas shutoff valve
F. ½" (1.3 cm) or ¾" (1.9 cm) gas pipe
G. Use pipe-joint compound.
H. Adapter
Complete Connection
1. Check that the gas pressure regulator shutoff valve is in the
“on” position.
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column.
Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
This range is factory-set for use with Natural gas. To use this range with LP gas, see the “Gas Conversions” section before connecting this range to the gas supply. Gas conversions from
Natural gas to LP gas or from LP gas to Natural gas must be done by a qualified installer.
Typical Flexible Connection
1. Apply pipe-joint compound made for use with LP gas to the smaller thread ends of the flexible connector adapters. See B and G in the following illustration.
2. Attach one adapter to the gas pressure regulator and the other adapter to the gas shutoff valve. Tighten both adapters, being certain not to move or turn the gas pressure regulator.
A
A. Gas pressure regulator shutoff valve shown in the “on” position
2. Open the manual shutoff valve in the gas supply line. The valve is open when the handle is parallel to the gas pipe.
A
B
A. Closed valve
B. Open valve
3. Test all connections by brushing on an approved noncorrosive leak-detection solution. If bubbles appear, a leak is indicated. Correct any leak found.
11
4. Remove cooktop burner caps and bases from package containing parts. Place the burner bases as indicated by the following illustration for your model:
For Models MGS8880D, WEG730H0D, and WEG760H0D:
5. Align the gas tube opening in the burner base with the orifice holder on the cooktop and the igniter electrode with the notch in the burner base.
A
A D
B
C
E
C
D
B
A. Small
B. Large
C. Medium D. Medium
E. Large
For Models KSGG700E and KSGB900E:
E
A. Burner cap
B. Gas tube opening
C. Burner base
D. Igniter electrode
E. Orifice holder
6. Place the burner caps on the appropriate burner bases.
IMPORTANT: The bottom of the small and medium caps are different. Do not put the wrong size burner cap on the burner base.
A D
C
B
A. Small
B. X-Large
For Model JGS1450D:
C. Medium D. Medium
E. Large
E
Small cap Medium cap Large cap X-Large cap
Burner caps should be level when properly positioned. If burner caps are not properly positioned, surface burners will not light. The burner cap should not rock or wobble when properly aligned.
A
A D
B
A. Incorrect
B. Correct
WARNING
C
B
A. Small
B. X-Large
C. Oval D. Medium
E. Large
E
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
7. Plug into a grounded 3 prong outlet.
12
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 2 RANGE SAFETY
- 4 INSTALLATION REQUIREMENTS
- 4 Tools and Parts
- 4 Location Requirements
- 7 Electrical Requirements
- 7 Gas Supply Requirements
- 9 INSTALLATION INSTRUCTIONS
- 9 Unpack Range
- 9 Install Anti-Tip Bracket
- 10 Adjust Leveling Legs
- 11 Level Range
- 11 Make Gas Connection
- 13 Verify Anti-Tip Bracket Is Installed and Engaged
- 13 Electronic Ignition System
- 14 Remove/Replace Drawer
- 14 Oven Door
- 15 Complete Installation
- 16 GAS CONVERSIONS
- 16 LP Gas Conversion
- 19 Natural Gas Conversion
- 22 Adjust Flame Height
- 24 SÉCURITÉ DE LA CUISINIÈRE
- 26 EXIGENCES D’INSTALLATION
- 26 Outillage et pièces
- 26 Exigences d'emplacement
- 29 Spécifications électriques
- 29 Spécifications de l’alimentation en gaz
- 31 INSTRUCTIONS D’INSTALLATION
- 31 Déballage de la cuisinière
- 31 Installation de la bride antibasculement
- 32 Réglage des pieds de nivellement
- 33 Réglage de l’aplomb de la cuisinière
- 33 Raccordement au gaz
- 35 installée et engagée
- 36 Système d’allumage électronique
- 37 Dépose et réinstallation du tiroir
- 37 Porte du four
- 38 Achever l’installation
- 39 CONVERSIONS POUR CHANGEMENT DE GAZ
- 39 Conversion pour l’alimentation au propane
- 43 Conversion pour l’alimentation au gaz naturel
- 46 Réglage de la taille des flammes