Aborted Installation. Mylex DAC960PG

Add to My manuals
68 Pages

advertisement

Aborted Installation. Mylex DAC960PG | Manualzz

Aborted Installation

During the initialization, if the firmware fails to respond to the BIOS inquiry within two minutes, the following message displays:

DAC960P n not responding--no drives installed.

The BIOS then inquires the firmware for its version number and other information, and prints out the following message:

DAC960P n firmware version x.xx

One or more of the following messages will be displayed if the firmware reports the following conditions:

Warning: X system drives are offline

Warning: X system drives are critical

Warning: The following SCSI devices are dead--chn x, tgt y...

No system drives found: None installed

X system drives installed

The BIOS repeats the same process for additional RAID controllers present in the system. Then it proceeds to boot, if possible, from the first system drive on the first controller.

Aborted Installation

With Firmware 4.x, the installation aborted message is displayed when the

BIOS finds that the configuration of the disk drives, as stored in the

NVRAM and configuration on disk, is different from what it senses at boot time. When this happens, (and a brand new installation is not being attempted) the cause is often a faulty cable or drive, or a loose connection.

Check all of the connectors, cables, drives, and try to boot. If the error persists, it most likely indicates a genuine failure and needs to be corrected.

To correct it, boot and run the on-board Mylex Disk Array Configuration

Utility (see Chapter 4). For more information, refer to the Disk Array

Controller Configuration Utilities (DACCF) Installation Guide and User

Manual (P/N 771953).

C-2 DAC960PG/PJ Installation Guide