7845GSM/7845GSMCN Installation and Setup Guide
TRIG.
62
63
64
Restore Zn8 Y/N
(Y)_
Delay Zn8 (secs)
(00)_
Review? Y/N
✔
2-4204
2-
4204 only
2-
4204 only
✔
[Y], [N]
DESCRIPTION
Enables restore reporting for zone 8.
[01-15]
[00] = no delay
Defines the reporting delay in seconds for zone 8.
[Y] = review
[N] = exit
Reviewing Programming Mode Entries
To review the programming options (to ensure that the correct entries have been made), press
[Y]. The programming questions are displayed again. Use the up/down arrow keys to scroll through the program fields without changing any of the values. If a value requires change, simply type in the correct value. When the last field is displayed, the “REVIEW?” question again appears.
To exit the programming mode, press [N] in response to the "REVIEW?" question, and refer to Exiting Programming Mode below.
Exiting Programming Mode
To exit the programming mode, press [N] in response to the "REVIEW?" question. Then press
[Y] to the "Exit Prog Mode?" question. Upon exiting, the root file is updated to log the changes made. A message is displayed telling the user that this step is being executed. When complete, the message "DONE" is displayed to indicate the file was successfully uploaded.
If critical configuration changes were made, such as the mode of operation, the 7845GSM will reset to ensure that the programming features are enabled.
If the file is not successfully uploaded, one of the following prompts will be displayed. Follow the steps shown below until the upload is successful.
Display
Cannot Upload
Try Again? Y/N_
Failed to Update
Root File!
Description
GSM module is not yet initialized. Wait for RSSI LEDs to be lit.
Network problem, or you answered "N" to "Cannot Upload
Try Again?" prompt.
What to do
Press [Y].
Initiate the Force Server Update command by pressing the [0] key; refer to Section 5: Programmer Keyboard
Commands.
Setting Factory Defaults
To reset the programming options to factory-default values, press [ESC] at the "Exit Prog
Mode?" prompt.
Set Default?
Y/N_
Press [Y] to reset factory default values.
Press [N] to cancel this function.
If you press [Y], all programmed values are reset to the original factory settings. PLEASE
NOTE THAT THIS WILL ERASE ANY PASSWORD THAT MAY HAVE BEEN ENTERED.
After pressing [Y], the Create Password prompt appears (see Prompt 4).