Section 4: Registration
Possible Errors
Registration BAD
Timed Out
Registration BAD
Pri Sub ID BAD
Registration BAD
2nd Sub ID BAD
Registration BAD
Pri&Sec – IDs BAD
Registration BAD
Pri ID – Need PIN
Registration BAD
2nd ID – Need PIN
Registration BAD
Pri&2nd – Need PIN
Displayed if no response to the registration request is received.
Indicates the city, central station, or customer number for the labeled account(s) is not accepted. The ID information was either entered in error, or the central station failed to pre-authorize programmed ID numbers with AlarmNet customer service.
Indicates the city, central station, or customer number for the Secondary account is not accepted. The ID information was either entered in error, or the central station failed to pre-authorize programmed ID numbers with AlarmNet customer service.
Displayed when both primary and secondary subscriber
IDs are invalid.
Displayed if this is a repair/replacement, or an error was made in programming the Primary account information of 7845GSM for an existing account. This prompt appears for 2 seconds. See the Replacing an existing
module section below for further displays.
This prompt is displayed if this is a repair/replacement, or an error was made in programming the Secondary account information of 7845GSM for an existing account.
This prompt appears for 2 seconds. See the Replacing
an existing module section below for further displays.
This prompt is displayed if this is a repair/replacement, or an error was made in programming BOTH the
Primary and Secondary account information of
7845GSM for an existing account. This prompt appears for 2 seconds. See the Replacing an existing module section below for further displays.
Replacing an existing module using the programming tool
Enter PIN#
This prompt appears after pressing the down arrow [ provided by your central station, your dealer or an authorized AlarmNet representative.
↓↓↓↓] on the 7720P. Enter a 4-digit alphanumeric PIN number
Registering …
Registration
SUCCESS
NOTE: If you are replacing an existing "C Series" radio, you can enter the last four-digits of the "C Series" MIN number.
Press the [ENTER] key.
The registration message is sent and the unit waits for acknowledgement.
If the PIN is valid, the new 7845GSM is registered and the old unit unregistered. Additionally, AlarmNet sends a substitution alarm to the central station.
WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
4-3
7845GSM/7845GSMCN Installation and Setup Guide
Registration BAD
If you entered an invalid PIN, the appropriate message is displayed depending on which account number is being replaced (see above for exact wording). The registration process is repeated.
NOTE: Each attempt causes a substitution alarm to be sent to the central station.
Register by Phone
You can register the module by calling the AlarmNet Technical Assistance Center (TAC) at
1-800-222-6525.
You will need the following information:
• MAC number (found on the label).
• Subscriber information (provided by the central station), including a city code,
CSID, and a subscriber ID.
• When instructed to do so, triple-click the tamper switch to complete the registration.
4-4 WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
S E C T I O N 5
Programmer Keyboard Commands
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Programmer Keyboard Commands
Programmer keyboard commands can be used to quickly view your connectivity settings and options. Most commands require you to press the [shift] key and then the designated command key. (See the keys designated in red on the 7720P Programming Tool.)
[A]
7845GSM x.x.xx mm/dd/yy
Software Revision
"x.x.xx" indicates the installed software Revision.
Mm/dd/yy indicates month, day and year of the revision.
Module Identification Displays
[B]
MAC xxxxxxxxxxxx
MAC CRC yyyy
[C]
SCID xxxxx xxxxx
xxxxx xxxxx
IMEI xxxxxxxx
xxxxxx x
Mon 01 Jan 2001
05:48:39 am
MAC Address
“xxxxxxxxxxxx” indicates the 7845GSM's unique identification number.
"yyyy" indicates the MAC CRC number. This number is also found on the label on the module, as well as the label on the box.
Press the [space] key to go to the next field.
Press the [backspace] key to go to the previous field.
SCID Display
Displays the identification number assigned to the SIM card (SCID) in this device.
Press the [space] key to go to the next field.
Press the [backspace] key to go to the previous field.
IMEI Display
Displays the identification number assigned to the
GSM module in this device.
Press the [space] key to get the MAC Address.
Press the [backspace] key to go to the previous field.
Time
Retrieves the current date and time from the AlarmNet network in Greenwich Mean Time (GMT). This display confirms that the module is in sync with network.
5-1
WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
7845GSM/7845GSMCN Installation and Setup Guide
GSM Status Displays
[E]
[S]
PriRSSI GPRS REG
-xxxdbm x x
Cntry Netw LAC xxx xxx xxxxx
Cell BaseSt Chan xxxxx x xxx
Second Site RSSI
-xxxdbm
GSM Status Display Screen 1
PriRSSI – Primary Site RSSI level in dbm
GPRS – GPRS Service availability where “x” can be:
“Y” if GPRS is available
“N” if GPRS is Not available
REG – Registration status from radio module where
“x” can be:
N – Not Registered
H – Registered Home
S – Searching
D – Registration Denied
R – Registered Roaming
? – Unknown Registration State
Press the [space] key to go to the next screen.
Press the [backspace] key to go to the last screen.
GSM Status Display Screen 2
Cntry – Country Code
Netw – Network Code
LAC – Local area code
Press the [space] key to get to the next screen.
Press the [backspace] key to go to the previous field.
GSM Status Display Screen 3
Cell – Base Station ID
BaseSt – Base Station Antenna Sector
Chan – Control Channel in use
Press the [space] key to go to the next screen.
Press the [backspace] key to go to the previous field.
GSM Status Display Screen 4
Secondary GSM Site RSSI level in dbm.
Press the [space] key to go to the GSM Status Display
Screen 1.
Press the [backspace] key to go to the previous field.
System Status Displays
ECP 67 TmPB Flt
xx 5 ++ OK
1234 67 TmPB Flt
5555 xx 5 ++ OK
ECP Mode
Displays the zone and system fault status.
Press the [space] key to go to the next field.
Press the [backspace] key to go to the previous field.
4204 Emulation Mode
Displays the zone and system fault status.
Press the [space] key to go to the next field.
Press the [backspace] key to go to the previous field.
5-2 WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
Section 5: Programmer Keyboard Commands
12345678 TmPB Flt
5555555x 5 ++ OK
1234567 TmPB Flt
5555555 5 ++ OK
Bat NLd: x.xxV
Bat Ld: x.xxV
Battery Charger
OK
Two-4204 Emulation Mode
Displays the zone and system fault status.
Press the [space] key to go to the next field.
Press the [backspace] key to go to the previous field.
Zone Trigger Mode
The status of the 7845GSM can be viewed on the
7720P. The status display includes:
• Zone input status (1234567) - the numbers 1-7 represent the 7 mappings of the zone input, and follow Honeywell's ADEMCO high-speed format codes:
1 = New Event
5 = Normal
X = Not Enabled
•
Tm – Tamper status follows high-speed format codes above.
•
•
P – Represents line voltage as follows:
+ = Power line voltage OK
- = Power line voltage bad and reported
V = Power line voltage bad, not reported
(reporting window not expired)
^ = Power voltage restored, not yet reported
B – Represents battery condition as follows:
+ = Battery voltage acceptable
- = Battery voltage below 5.7V ±5%
• Flt – Represents radio faults:
OK = Normal ; No fault
G = No network connectivity over GSM and fault time has expired.
g = No network connectivity over GSM and fault time has NOT yet expired.
NOTE: The 7720P will not operate if the power line voltage is removed.
Battery Voltage Display
The voltage levels of the battery connected to the
7845GSM can be viewed on the 7720P. The first line of the display shows the voltage level of the battery with no load The second line of the display shows loaded battery voltage. An asterisk (*) next to the voltage indicates that this is below the accepted level.
Press the [space] key to go to the next field.
Press the [backspace] key to go to the previous field.
Battery Charger Status Display
The status of the battery charger circuit of the
7845GSM can be viewed on the 7720P. The status is either OK or NOT OK.
Press the [space] key to go to the next field.
WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
5-3
7845GSM/7845GSMCN Installation and Setup Guide
[T]
[X]
[ ↑↑↑↑]
(UP arrow)
[ ↓↓↓↓]
(DN arrow)
[0]
Line Voltage xx.xxV
Test Msg Sent
Reset CPU Y/N
Registering …
Enter PIN#
Force Server Update?
Y/N
Press the [backspace] key to go to the previous field.
Line Voltage Display
The line voltage of the 7845GSM can be viewed on the
7720P. An asterisk (*) next to the voltage indicates that this is below the accepted level.
Press the [space] key to go back to the System Status
Display.
Press the [backspace] key to go to the previous field.
Test Alarm
Sends a Test alarm to AlarmNet. Functional for a
registered 7845GSM only. If the device is not registered, a message is displayed indicating that the command cannot be executed.
NOTE: If two CSIP’s are used, test alarms are sent to
each central station. In addition, if the primary fails to report, a second (backup) message is sent to the secondary station.
Reset the 7845GSM.
Pressing [N] returns to normal mode.
Pressing [Y] resets the device.
Registration
Registers a programmed 7845GSM with AlarmNet.
Registration with PIN for Replacement Module
Registers a replacement 7845GSM with AlarmNet, once programmed, using the existing PIN #.
Force Upload of Configuration File to Server
Pressing [Y] will force the device to upload its entire configuration file to the server.
Pressing [N] cancels the operation.
NOTE: If the GSM module is not initialized when you enter this command, the following screen will be displayed:
Cannot Upload
Try Later! _
Wait for the RSSI LEDs to light, indicating the GSM module has completed its initialization, and try again.
[ENTER]
Strt Prog Mode?
Y/N_
Enter Program Mode
Press [Y] to enter program mode; otherwise, press [N].
5-4 WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
S E C T I O N 6
Appendices
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Appendix A: Summary of LED Operation
7845GSM Status Display Operation
The 7845GSM Status Display has three LEDs used to indicate message and device status:
• STATUS, green
• MESSAGE, yellow
• FAULT, red
GREEN
(STATUS)
YELLOW
(MESSAGE)
RED
(FAULT)
7845i-GSM-012-V0
Figure 13. 7845GSM Status Display LEDs with Front Cover Installed
Each LED can have four different states - ON, OFF, FAST BLINK and SLOW BLINK.
Throughout this document, the following key is used to describe LED state:
ON OFF FAST BLINK
Figure 14. LED Key
SLOW BLINK
WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
6-1
7845GSM/7845GSMCN Installation and Setup Guide
Table 6. Status Display Operation
LED COLOR
GREEN
YELLOW
RED
ALL
LED
STATUS
MESSAGE
FAULT
DESCRIPTION
ON – 7845GSM is NOT registered with AlarmNet.
OFF – 7845GSM is registered with AlarmNet.
FAST BLINK – Download session with Compass in progress.
SLOW BLINK – In unison with yellow LED – Registration in progress.
ON – Message transmission pending.
QUICK PERIODIC BLINK - Normal
FAST BLINK – Message waiting for network ACK.
SLOW BLINK – Idle, power abnormal.
– In unison with green LED – Registration in progress.
ON – No contact with network.
OFF– Normal.
SLOW BLINK – Loss of communication with the panel (ECP fault).
FAST BLINK – No network contact AND loss of communication with the panel.
FAST BLINK – In unison with the RSSI Bar Graph LEDs –
Hardware Error. Call the AlarmNet Technical
Assistance Center.
A B
STATUS, GREEN STATUS, GREEN
MESSAGE, YELLOW MESSAGE, YELLOW
FAULT, RED FAULT, RED
Figure 15. A Registered 7845GSM Status Display (A) and an Unregistered 7845GSM Status Display in Normal Operating State(B)
1 2 3 4
STATUS, GREEN
MESSAGE, YELLOW
FAULT, RED
Figure 16. LED Sequence for a Registered 7845GSM Message Transmission
6-2 WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
Section 6: Appendices
Signal Strength (RSSI) / Mode and Status LEDs
The Signal Strength (RSSI) / Mode and Status LEDs normally display the module’s signal strength. LED 1 (red LED on the left) will be lit to indicate that the display is in RSSI mode, and the other LEDs indicate signal strength (lowest to highest, from left to right) between the module and the receiving tower. Signal strength should be within 3-5 bars.
Mode and Status Indicator Switch
Press and hold the Mode and Status Indicator Switch to change the LED functions in order to view the mode of operation and network carrier status. When the switch is held down,
LED 1 (red LED on the left) will be off, and the LEDs from left to right have the following meanings:
Table 7. LED Functions with Mode and Status Indicator Switch Depressed
LED 1
(red)
Off=Mode and Status indicator
Operation Modes (
Table 7a
)
LED 2
(yellow)
Operation
Mode (in combination with LED 3)
LED 3 (yellow)
Operation Mode (in combination with
LED 2)
Status Indications (
Table 7b
)
LED 4
(green)
Not Used
LED 5
(green)
GPRS
Service
LED 6
(green)
GSM
Module
Registration with
Network
Carrier
(see below for specific modes and status indications)
ECP
Zone
4204
2 - 4204
Table 7a. Operation Modes
OPERATION MODE
(1
LED 2 st
yellow) (2
LED 3 nd
yellow)
OFF OFF
ON OFF
OFF ON
ON ON
STATUS
Table 7b. Status Indications
(1
LED 4 st
green) (2
LED 5 nd
green)
SLOW BLINK – available
–
(3
LED 6 rd
green)
GSM module not registered with network carrier
GSM module registered—second site available–low signal strength
GSM module registered—second
NORMAL
BLINK
FAST BLINK
ON
–
Not Used
GPRS in use by device
GPRS service available strength
GSM module registered—second site available–excellent signal strength
GSM module registered—no second site available
WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
6-3
7845GSM/7845GSMCN Installation and Setup Guide
Appendix B: Central Station Messages
The following messages are sent by the 7845GSM module for the conditions listed below.
Alarm Condition
Power On Reset
Tamper
Power Loss
Table 8: 7845GSM Central Station Messages
ECP Mode
Alarm Code
E339 C08xx*
ECP Mode
Restore Code
Zone and 4204
Modes
Alarm Code
5551 5555 6
E341 C08xx* R341C 08xx* 5555 5551 7
E337 C08xx* R337 C08xx* 1555 5555 6
Low Battery E338 C08xx* R338 C08xx* 5155 5555 6
Battery Charger Failure E314 C08xx* R314 C08xx* 5155 5555 1
Zone and 4204
Modes
Restore Code
5555 5553 7
3555 5555 6
5355 5555 6
5355 5555 1
ECP Supervision
Communication Path
Supervision
Swinger Suppression
Telco
Open/Close
Test
* xx = 7845GSM Device Address
E355 C0000
5555 5555 9
R355 C0000
R350 C0951
5555 5515 5
0D00 0005 0
5555 5155 6
2 sent in selected zone
5555 5555 9
The control panel sends its own general code (E353) for a trouble condition.
5555 5535 5
5555 5553 5
5555 5355 6
4 sent in selected zone
6-4 WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
Section 6: Appendices
Appendix C: GSM Downloading
General Information
The 7845GSM can be used to provide high-speed up/downloading to Honeywell VISTA and
LYNXR-I control panels over the GPRS network. This allows site maintenance independent of central station monitoring, and modification to sites globally. At this time, some control panels support downloading through the ECP bus and some panels support downloading through the use of a Direct Wire connection. Residential panels such as the VISTA-20P and
LynxR-I support ECP downloading .
Currently, commercial controls such as VISTA-128BP and FBP support downloading through use of a Direct Wire connection (using the trigger connections on the control panel).
UL
Downloading may only be performed if a technician is at the site.
Direct Wire Setup
To perform up/downloading using Direct Wire, the 7845GSM requires that Direct Wire
Downloading is enabled (Enable DW), and that the ECP device address on which the
7845GSM communicates with the control panel as a keypad is entered (Direct Wire Address).
Additionally, the 7845GSM must be connected by cable as shown below to the panels listed.
NOTE: This feature is not available if device is set for zone trigger mode.
VISTA-128BP/250BP
FA1660C
J8 CONNECTOR
PROGRAMMER
PORT
1 2 3 4 5 6 7 8 9
WHITE
NU
BLUE
7845GSM
FOR EXTERNAL ANTENNA
50 OHM, MMCX ONLY
K4668WH
RJ 11 CABLE
IN 2
PRINTER DTR
IN 3
GR
OUND
OUT 5 OUT 6
GR
OUND
GR
OUND
4142 TR CABLE
TB 1
1
4
5
2
3
10
11
8
9
6
7
Honeywell
1
PARTS SUPPLIED WITH DOWNLOADER KIT P/N VBPCOMKIT
2
VISTA-128FBP/250FBP
FA1670C /FA1700C
J2 CONNECTOR
3 4 5 6 7 8 9
TO
AUX PWR 1
OUTPUT
OUT 4 OUT 7 OUT 3 OUT 6 OUT 2 OUT 5 OUT 1
GR
OUND
INPUT 1
4142 TR CABLE
+ (TO TERM 11)
- (TO TERM 12)
4100SM
3
2
1
8
7
6
5
4
+ PWR
- (GND)
RXD not used not used
TXD not used not used
RED BLUE WHITE
PROGRAMMER
PORT
TB 1
1
2
3
10
11
8
9
6
7
4
5
7845GSM-026-V0
7845GSM
FOR EXTERNAL ANTENNA
50 OHM, MMCX ONLY
Honeywell
PARTS SUPPLIED WITH DOWNLOADER KIT P/N VFBPCOMKIT
K14394LF 25-PIN TO RJ11 CABLE
7845GSM-025-V0
Figure 17. Cable Connections for Direct Wire Downloading
WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
6-5
7845GSM/7845GSMCN Installation and Setup Guide
Appendix D: Glossary
AES – Advanced Encryption Standard
DHCP – Dynamic Host Configuration Protocol, which provides a mechanism for allocating IP addresses dynamically so that addresses can be reused when hosts no longer need them.
DNS – Domain Name System, which is a distributed hierarchical naming system used to resolve domain names (e.g., www.yahoo.com) into numerical IP addresses (e.g., 204.17.25.1.).
DSL – Digital Subscriber Line
ECP – Enhanced Console Protocol, which is a proprietary communications bus used in
Honeywell VISTA control panels for wiring additional keypads and peripheral devices; consists of a four-wire data bus (power+/-, data in/out).
Gateway IP Address - A gateway (sometimes called a router) is a computer and/or software used to connect two or more networks (including incompatible networks) and translates information from one network to the other. The Gateway IP address is the IP address for the gateway.
GPRS – (General Packet Radio Service)
GSM – Global System for Mobile communications, which is an international standard for digital mobile phone systems used for cellular communication.
IMEI – International Mobile Equipment Identity number
IP – Internet Protocol
IP Address – A unique number consisting of four parts separated by periods, sometimes called a "dotted quad.," for example: 204.17.29.11, assigned to every computer/workstation connected to the Internet. IP numbers can be "static" (assigned and unchanging) or
"dynamic," assigned via DHCP at each and every startup.
ISDN – Integrated Services Digital Network
ISP – Internet Service Provider
LAN – Local Area Network
MAC Address – Media Access Code; located on the module label.
PPPoE – Point-to-Point Protocol over Ethernet
Subnet Mask - A Subnet is a portion of a network that shares a network address with other portions of the network, and is distinguished by a subnet number. The Subnet Mask is a 32bit address mask used in IP to indicate the bits of an IP address that are being used for the subnet address.
TCP/IP – Transmission Control Protocol / Internet protocol
6-6 WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
Notes:
Section 6: Appendices
WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
6-7
7845GSM/7845GSMCN Installation and Setup Guide
FCC AND INDUSTRY CANADA STATEMENT
This device complies with Part 15 of the FCC Rules and RSS210 of Industry Canada.
Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This Class B digital apparatus complies with Canadian ICES-003.
Cet Appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
FEDERAL COMMUNICATIONS COMMISSION (FCC) STATEMENT
This equipment has been tested to FCC requirements and has been found acceptable for use.
The FCC requires the following statement for your information:
This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part
15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• If using an indoor antenna, have a quality outdoor antenna installed.
• Reorient the receiving antenna until interference is reduced or eliminated.
• Move the radio or television receiver away from the receiver/control.
• Move the antenna leads away from any wire runs to the receiver/control.
• Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits.
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user or installer may find the following booklet prepared by the Federal Communications Commission helpful:
"Interference Handbook"
This booklet is available under Stock No. 004-000-00450-7 from the U.S. Government
Printing Office, Washington, DC 20402.
The user shall not make any changes or modifications to the equipment unless authorized by the Installation and Setup Guide or User Guide. Unauthorized changes or modifications could void the user's authority to operate the equipment.
6-8 WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
7845GSM Summary of Connections
INTERNAL
ANTENNA
STATUS LED
MESSAGE LED
FAULT LED
MOUNTING
HOLE (TYP.)
7720P PROGRAMMER PORT/
PANEL DOWNLOAD PORT
FOR EXTERNAL ANTENNA
50 OHM MMCX ONLY
PRIMARY POWER: 9 - 16.5 VAC
CURRENT: 900mA PEAK, 70mA STANDBY
BATTERY: 8V. 3.1 AHr FOR 24 Hr BACKUP
FCC:XXXXXXXXXX IC: YYYYYYYYYY
AC 1
AC 2
NOT USED or 12V DC IN
GND
ZONE INPUT Z1/Z2 or ECP INPUT
ZONE INPUT Z3 or ECP OUTPUT
ZONE INPUT Z4 or NOT USED
ZONE INPUT Z5 or NOT USED
ZONE INPUT Z6 or NOT USED
ZONE INPUT Z7 or NOT USED
FAULT OUTPUT
MOUNTING HOLE
TAMPER SWITCH
TB 1
1
7
8
9
10
11
2
3
4
5
6
BLACK RED
SIGNAL
STRENGTH
(RSSI)/MODE
AND STATUS
LEDs
MOUNTING
HOLE
(UNDER
BATTERY)
BLK
RED
BATTERY
CLIP
BATTERY
J1
BATTERY
CONNECTOR
SIGNAL STRENGTH (RSSI)/
MODE AND STATUS INDICATOR
SWITCH
SCREW
1
2
7
8
9
10
11
3
4
5
6
TB1
TB1 Wiring for 7845GSM Cellular Communicator
ECP
Mode
AC 1
AC 2
Zone
Trigger
Mode
AC 1
AC 2
4204
Mode
AC 1
AC 2
2 x 4204
Mode
AC 1
AC 2
ECP V+ (RED) NOT USED ECP V+ (RED)
GND (BLK) GND (BLK) GND (BLK)
ECP IN (YEL)
ECP OUT (GRN)
Z1/Z2
Z3
ECP IN (YEL)
ECP V (RED)+
GND (BLK)
ECP IN (YEL)
ECP OUT (GRN) ECP OUT (GRN)
NOT USED
NOT USED
Z4
Z5
NOT USED
NOT USED
NOT USED
NOT USED
FLT OUT FLT OUT FLT OUT FLT OUT
7845GSM-006-V0
WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
LIMITED WARRANTY
Honeywell International Inc., acting through its Security & Custom Electronics business ("Seller") 165
Eileen Way, Syosset, New York 11791, warrants its product(s) to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 24 months from the date stamp control on the product(s) or, for product(s) not having a manufacturer's date stamp, for 12 months from date of original purchase unless the installation instructions or catalog sets forth a shorter period, in which case the shorter period shall apply. Seller's obligation shall be limited to repairing or replacing, at its option, free of charge for materials or labor, any product(s) which is proved not in compliance with Seller's specifications or proves defective in materials or workmanship under normal use and service. Seller shall have no obligation under this Limited
Warranty or otherwise if the product(s) is altered or improperly repaired or serviced by anyone other than
Honeywell factory service. Connection of any device(s) to a communication bus of a Honeywell security system (e.g., keypad bus, polling loop) other than those manufactured or approved by Honeywell shall void this warranty. For warranty service, return product(s) transportation prepaid, to Honeywell Factory
Service, 165 Eileen Way, Syosset, New York 11791.
THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR
A PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION ON
THE FACE HEREOF. IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY
CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER
WARRANTY, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER,
EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S OWN NEGLIGENCE OR FAULT.
Seller does not represent that the product(s) it sells may not be compromised or circumvented; that the product(s) will prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that the product(s) will in all cases provide adequate warning or protection. Customer understands that a properly installed and maintained alarm system may only reduce the risk of a burglary, robbery, fire, or other events occurring without providing an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a result. CONSEQUENTLY, SELLER
SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LOSS
BASED ON A CLAIM THAT THE PRODUCT(S) FAILED TO GIVE WARNING. HOWEVER, IF SELLER IS
HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS OR DAMAGE ARISING
UNDER THIS LIMITED WARRANTY OR OTHERWISE, REGARDLESS OF CAUSE OR ORIGIN,
SELLER'S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE
PRODUCT(S), WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER.
This warranty replaces any previous warranties and is the only warranty made by Seller on this product(s). No increase or alteration, written or verbal, of the obligations of this Limited Warranty is authorized.
165 Eileen Way, Syosset, NY 11791
Copyright
2006 Honeywell International Inc. www.honeywell.com/security
ÊK14184V1AŠ
K14184V1 11/06 Rev. A
WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
Download
Advertisement