Recessed and closet installation instructions

Recessed area minimum installation spacing

Fire Hazard l

It is recommended that the dryer be exhausted outside l

If washer/dryer is installed in a closet, the dryer MUST be exhausted outside.

Failure to do so may cause a fire.

This washer/dryer may be installed in a recessed area or closet.

The installation spacing is in inches and is minimum allowable. Additional spacing should be considered for ease of installation, servicing and compliance with local codes and ordinances.

If closet door is installed, the minimum unobstructed air openings in top and bottom are required. Louvered doors with equivalent air openings are acceptable. Closet installation must be exhausted.

Other installations must use the minimum dimensions indicated.

TO PREVENT LARGE AMOUNTS OF LINT

AND MOISTURE FROM ACCUMULATING,

TO MAINTAIN DRYING EFFICIENCY, THIS

APPLIANCE SHOULD BE EXHAUSTED

OUTDOORS. a- 3”

Washer

I

•I .

Side View Front View

Recessed, non-exhausted installation must use only the rear exhaust position and Exhaust Deflector Part No. 694609.

Note: If recessed installation is exhausted to the side or rear, 6 inches must be available above the washer/dryer but all other spacing can be 0 inches.

J

Closet installation must be exhausted outdoors.

/

Closet Door

4

6” f

48. sq. in. +*

4

1” min.+

24. sq. in. l

*

Side View

Closet Door sq. in. l

*

Product dimensions

1+26-l/4’ +I

+27-3/a” -

-i sq. in. l

*

4

Front View

* Additional clearances for wall, door and floor moldings may be required or if external exhaust elbow is used.

** Opening is minimum for closet door, Louvered door with equivalent air openings is acceptable.

*** $MiEnal space may be needed for exhaust

Panel G