- Computers & electronics
- Computer components
- System components
- Internal hard drives
- Seagate
- ST173404FC
- Product Manual
advertisement
Cheetah 73FC Product Manual, Rev. C 55
9.5.11.1
Parallel Enclosure Services Interface (ESI)
The parallel ESI line is an output from the drive. This line provides the enclosure with an indication of the present function of the SEL lines. A high level, the default state, indicates the drive requires address information on the SEL lines. A low level indicates the drive is attempting an ESI transfer. The enclosure may not support ESI on any or all drive locations. It may only support the address function. Support of ESI is discovered by the drive. Refer to the Fibre Channel Interface Manual for a description of ESI operations.
9.5.12
Device control codes
The drive inputs a Device Control Code on the DEV_CTRL_CODE lines at power up to determine the link rate on the Fibre Channel ports. Both ports run at the same rate. If the backpanel does not connect to these lines,
supported codes.
Table 22: Device control code values
2 (pin 17) 1 (pin 18) 0 (pin 39) Definition
0
1
1
1
1
0
0
0
1
1
0
0
1
1
0
0
1
0
1
0
1
0
1
0
Power failure warning.
Reserved for auto negotiation of link rate.
Reserved.
Reserved.
Reserved.
Reserved.
2.125 GHz operation on both ports.
1.0625 GHz operation on both ports.
56
SEL ID
(hex)
1C
1D
1E
1F
18
19
1A
1B
14
15
16
17
10
11
12
13
0C
0D
0E
0F
08
09
0A
0B
04
05
06
07
00
01
02
03
24
25
26
27
20
21
22
23
28
29
2A
Table 23: Arbitrated loop physical address (AL_PA) values
AL_PA
(hex)
B6
B5
B4
B3
C3
BC
BA
B9
C9
C7
C6
C5
CD
CC
CB
CA
D3
D2
D1
CE
D9
D6
D5
D4
E1
E0
DC
DA
EF
E8
E4
E2
A7
A6
A5
AC
AB
AA
A9
B2
B1
AE
AD
Setting
(dec)
28
29
30
31
24
25
26
27
20
21
22
23
16
17
18
19
12
13
14
15
08
09
10
11
04
05
06
07
00
01
02
03
36
37
38
39
32
33
34
35
40
41
42
AL_PA
(hex)
69
67
66
65
6D
6C
6B
6A
73
72
71
6E
79
76
75
74
81
80
7C
7A
8F
88
84
82
9B
98
97
90
A3
9F
9E
9D
56
55
54
53
63
5C
5A
59
52
51
4E
SEL ID
(hex)
47
48
49
4A
43
44
45
46
3F
40
41
42
3B
3C
3D
3E
37
38
39
3A
33
34
35
36
2F
30
31
32
2B
2C
2D
2E
4F
50
51
52
4B
4C
4D
4E
53
54
55
Setting
(dec)
71
72
73
74
67
68
69
70
63
64
65
66
59
60
61
62
55
56
57
58
51
52
53
54
47
48
49
50
43
44
45
46
79
80
81
82
75
76
77
78
83
84
85
Cheetah 73FC Product Manual, Rev. C
Setting
(dec)
114
115
116
117
110
111
112
113
106
107
108
109
102
103
104
105
122
123
124
125
118
119
120
121
98
99
100
101
94
95
96
97
90
91
92
93
86
87
88
89
SEL ID
(hex)
72
73
74
75
6E
6F
70
71
6A
6B
6C
6D
66
67
68
69
7A
7B
7C
7D
76
77
78
79
62
63
64
65
5E
5F
60
61
5A
5B
5C
5D
56
57
58
59
AL_PA
(hex)
1F
1E
1D
1B
27
26
25
23
2C
2B
2A
29
32
31
2E
2D
08
04
02
01
18
17
10
0F
36
35
34
33
43
3c
3A
39
49
47
46
45
4D
4C
4B
4A
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 11 Scope
- 13 Applicable standards and reference documentation
- 13 Standards
- 13 Electromagnetic compatibility
- 14 Reference documents
- 15 General description
- 16 Standard features
- 16 Media description
- 16 Performance
- 17 Reliability
- 17 Unformatted and formatted capacities
- 17 Programmable drive capacity
- 17 Factory-installed accessories
- 17 Factory-installed options
- 17 User-installed accessories
- 19 Performance characteristics
- 19 Internal drive characteristics
- 19 Seek performance characteristics
- 19 Access time
- 19 512-byte sectors
- 20 General performance characteristics
- 20 Start/stop time
- 20 Prefetch/multi-segmented cache control
- 21 Cache operation
- 21 Caching write data
- 22 Prefetch operation
- 23 Reliability specifications
- 23 Error rates
- 23 Environmental interference
- 23 Interface errors
- 23 Write errors
- 24 Seek errors
- 24 Reliability and service
- 24 Mean time between failure (MTBF)
- 24 Field failure rate vs time
- 25 Preventive maintenance
- 25 Service life
- 25 Service philosophy
- 25 Service tools
- 25 Hot plugging the drive
- 25 S.M.A.R.T
- 27 Drive Self Test (DST)
- 28 Product warranty
- 31 Physical/electrical specifications
- 31 AC power requirements
- 31 DC power requirements
- 32 Conducted noise immunity
- 32 Power sequencing
- 32 Current profiles
- 34 Power dissipation
- 34 Environmental limits
- 34 Temperature
- 36 Relative humidity
- 36 Effective altitude (sea level)
- 36 Shock and vibration
- 38 Air cleanliness
- 38 Acoustics
- 38 Electromagnetic susceptibility
- 39 Mechanical specifications
- 41 Defect and error management
- 41 Drive internal defects/errors
- 41 Drive error recovery procedures
- 42 FC-AL system errors
- 43 Installation
- 43 Drive ID/option selection
- 43 LED connections
- 44 J6 connector requirements
- 44 Drive orientation
- 44 Cooling
- 44 Air flow
- 45 Drive mounting
- 46 Grounding
- 47 Interface requirements
- 47 FC-AL features
- 47 Fibre Channel link service frames
- 47 Fibre Channel task management functions
- 47 Fibre Channel task management responses
- 48 Fibre Channel port login
- 49 Fibre Channel port login accept
- 49 Fibre Channel Process Login
- 49 Fibre Channel Process Login Accept
- 50 Fibre Channel fabric login
- 51 Fibre Channel fabric accept login
- 52 Fibre Channel Arbitrated Loop options
- 52 Dual port support
- 53 SCSI commands supported
- 56 Inquiry data
- 56 Mode Sense data
- 59 Miscellaneous operating features and conditions
- 60 FC-AL physical interface
- 60 Physical characteristics
- 61 Connector requirements
- 62 Electrical description
- 62 Pin descriptions
- 63 FC-AL transmitters and receivers
- 63 Power
- 63 Fault LED Out
- 63 Active LED Out
- 64 Enable port bypass signals
- 64 Motor start controls
- 64 SEL_6 through SEL_0 ID lines
- 65 Device control codes
- 67 Signal characteristics
- 67 TTL input characteristics
- 67 LED driver signals
- 67 Differential PECL output
- 68 Differential PECL input
- 69 Seagate Technology support services