8. OPTIONS AND PERIPHERAL EQUIPMENT. Mitsubishi Electric PUY-A-NHA3-BS, CC-Link IE Field Network
Add to my manuals164 Pages
advertisement
8. OPTIONS AND PERIPHERAL EQUIPMENT
8. OPTIONS AND PERIPHERAL EQUIPMENT
WARNING
Before connecting any option or peripheral equipment, turn off the power and wait for 15 minutes or more until the charge lamp turns off. Then, confirm that the voltage between P+ and N- is safe with a voltage tester and others. Otherwise, an electric shock may occur. In addition, when confirming whether the charge lamp is off or not, always confirm it from the front of the servo amplifier.
CAUTION
Use the specified peripheral equipment and options to prevent a malfunction or a fire.
The following item is the same as MR-J4-_B_ servo amplifiers. For details of the items, refer to each chapter/section of the detailed description field. "MR-J4-_B_" means "MR-J4-_B_(-RJ) Servo Amplifier
Instruction Manual".
Regenerative option
FR-BU2-(H) brake unit
MR-J4-_B_ section 11.2
MR-J4-_B_ section 11.3
FR-RC-(H) power regeneration converter MR-J4-_B_ section 11.4
FR-CV-(H) power regeneration common converter MR-J4-_B_ section 11.5
MR-J4-_B_ section 11.6 Junction terminal block PS7DW-20V14B-F
(recommended)
MR Configurator2 (Note) MR-J4-_B_ section 11.7
MR-J4-_B_ section 11.8
MR-J4-_B_ section 11.9
MR-J4-_B_ section 11.10
Battery
Selection example of wires
Molded-case circuit breakers, fuses, magnetic contactors (recommended)
Power factor improving DC reactor
Power factor improving AC reactor
Relay (recommended)
Noise reduction techniques
Earth-leakage current breaker
EMC filter (recommended)
External dynamic brake
Heat sink outside mounting attachment
(MR-J4ACN15K/MR-J3ACN)
MR-J4-_B_ section 11.11
MR-J4-_B_ section 11.12
MR-J4-_B_ section 11.13
MR-J4-_B_ section 11.14
MR-J4-_B_ section 11.15
MR-J4-_B_ section 11.16
MR-J4-_B_ section 11.17
MR-J4-_B_ section 11.18
Note. Use MR Configurator2 of software version 1.19V or later for the MR-J4-_B_-RJ010 servo amplifier.
8 - 1
8. OPTIONS AND PERIPHERAL EQUIPMENT
8.1 Combinations of cable/connector sets
POINT
The CN1A and CN1B connectors are not used. Always put caps came with the servo amplifier.
For connecting each servo motor, refer to "Servo Motor Instruction Manual (Vol.
3)".
When not using the STO function, attach the short-circuit connector came with the servo amplifier to CN8.
Please purchase the cable and connector options indicated in this section.
(Note 2)
6)
Safety logic unit
MR-J3-D05
CN9
5) 5)
Personal computer
CN10
2)
MR-J4-_B_-RJ010 servo amplifier 4)
MR-J4-_B_-RJ010 servo amplifier
1) (packed with the servo amplifier)
(Note 1)
CNP1
CN5
CN3 3)
CN5
CN3
CC-Link IE
Field Network controller
CNP2
CNP3
CN8
CN1A
CN10A
CN1B
CN10B
CN2
CN2L
CN4
MR-J3-T10
CN8
CN1A
CN10A
CN1B
CN10B
CN2
CN2L
CN4
MR-J3-T10
CC-Link IE
Field Network
7)
Battery
7)
Note 1. Connectors for 3.5 kW or less. For 5 kW or more, it is a terminal block.
2. When not using the STO function, attach the short-circuit connector ( 7)) came with a servo amplifier.
8 - 2
8. OPTIONS AND PERIPHERAL EQUIPMENT
Model Description power connector set
For CNP2
Connector:
06JFAT-SAXGDK-H7.5
Connector:
05JFAT-SAXGDK-H5.0
(JST) (JST)
Applicable wire size: 0.8 mm 2 to 2.1 mm 2
(AWG 18 to 14)
Insulator OD: to 3.9 mm
For CNP3
Connector:
03JFAT-SAXGDK-H7.5
(JST)
Open tool
J-FAT-OT
(JST)
Application
Supplied with servo amplifiers of 1 kW or less in 200
V class
Supplied with servo amplifiers of 2 kW and 3.5 kW in 200 V class Connector:
06JFAT-SAXGFK-XL
(JST)
(For CNP1 and CNP3)
Applicable wire size:
1.25 mm 2 to 5.5 mm 2
(AWG 16 to 10)
Insulator OD: to 4.7 mm
For CNP2
Connector:
05JFAT-SAXGDK-H5.0
(JST)
(For CNP2)
Applicable wire size:
0.8 mm 2 to 2.1 mm 2
(AWG 18 to 14)
Insulator OD: to 3.9 mm
For CNP3
Connector:
03JFAT-SAXGFK-XL
(JST)
Open tool
Quantity: 1
Model: J-FAT-OT-EXL
(JST)
Supplied with servo amplifiers of 3.5 kW or less in
400 V class
Cable length: 3 m
CNP1 connector:
06JFAT-SAXGDK-
HT10.5
CNP2 connector:
05JFAT-SAXGDK-
HT7.5
(JST) (JST)
Applicable wire size: 1.25 mm 2 to 2.1 mm 2
(AWG 16 to 14)
Insulator OD: to 3.9 mm mini-B connector (5 pins)
CNP3 connector:
03JFAT-SAXGDK-
HT10.5
(JST)
Open tool
J-FAT-OT-XL
(JST)
Personal computer connector
A connector
For connection with PC-AT compatible personal computer block
(recommended)
MR-J2HBUS_M
Connector: 10120-3000PE
Shell kit: 10320-52F0-008
(3M or equivalent)
PS7DW-20V14B-F
(Yoshida Electric industry)
Junction terminal block PS7DW-20V14B-F is not option. For using the junction terminal block, option MR-J2HBUS_M is necessary. For details, refer to section 11.6 of "MR-J4-_B_(-RJ) Servo Amplifier Instruction
Manual".
8 - 3
8. OPTIONS AND PERIPHERAL EQUIPMENT
5) STO cable
6) Short-circuit connector
7) Shielded twisted pair cable (Refer to section 8.2.)
Model Description Application
MR-D05UDL3M-B
(Refer to "MR-J4-
_B(-RJ) Servo
Amplifier
Instruction Manual" section 11.1.2.)
Connector set: 2069250-1
(TE Connectivity)
Connection cable for the CN8 connector
Supplied with servo amplifier
Shielded twisted pair cable (Category 5e)
The shielded twisted pair cable is not an option.
For CC-
Link IE
Field
Network
8.2 Cable for CC-Link IE Field Network
For the wiring of CC-Link IE Field Network, use the following wiring tools recommended by the CC-Link
Partner Association. The CC-Link IE controller network cable cannot be used for the CC-Link IE Field
Network.
Item Description
Cable type
Standard
Connector
Shielded twisted pair cable (Category 5e)
One of the following standards must be met.
IEEE802.3 1000BASE-T
ANSI/TIA/EIA-568-B (Category 5e)
Category 5e or more RJ-45 plug
A product example on the market is as follows. For the latest product information, contact the manufacturer.
Model Manufacturer Contact
SC-E5EW(-L)
(Note)
Mitsubishi Electric System & Service
Co., Ltd. email: [email protected]
Note. The SC-E5EW cable is for in-enclosure and indoor uses. The SC-E5EW-L cable is for outdoor use.
8 - 4
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 2 Safety Instructions
- 7 DISPOSAL OF WASTE
- 7 STO function of the servo amplifier
- 7 Compliance with global standards
- 8 About the manual
- 8 Cables used for wiring
- 8 U.S. customary units
- 10 CONTENTS
- 12 1. FUNCTIONS AND CONFIGURATION
- 12 1.1 Summary
- 13 1.2 Function block diagram
- 19 1.3 Standard specifications
- 19 1.3.1 Servo amplifier
- 21 1.3.2 MR-J3-T10 Field Network interface unit
- 21 1.4 Combinations of servo amplifiers and servo motors
- 23 1.5 Function list
- 24 1.6 Model designation
- 26 1.7 Structure
- 26 1.7.1 Parts identification
- 38 1.7.2 Parts identification of MR-J3-T10
- 39 1.8 Installation and removal of MR-J3-T10
- 43 1.9 Configuration including peripheral equipment
- 43 1.9.1 200 V class
- 49 1.9.2 400 V class
- 56 2. INSTALLATION
- 57 2.1 Installation direction and clearances
- 59 2.2 Keep out foreign materials
- 60 3. SIGNALS AND WIRING
- 62 3.1 I/O signal connection example
- 62 3.1.1 For sink I/O interface
- 64 3.1.2 For source I/O interface
- 65 3.2 Servo motor with an electromagnetic brake
- 65 3.2.1 Safety precautions
- 66 3.2.2 Timing chart
- 78 4. STARTUP
- 79 4.1 Switching power on for the first time
- 79 4.1.1 Startup procedure
- 80 4.1.2 Wiring check
- 83 4.1.3 Surrounding environment
- 83 4.2 Switch setting and display of the servo amplifier
- 83 4.2.1 Switches
- 86 4.2.2 Scrolling display
- 87 4.2.3 Status display of a station
- 89 4.3 Display of MR-J3-T10 CC-Link IE Field Network interface unit
- 90 5. PARAMETERS
- 90 5.1 Parameter list
- 91 5.1.1 Basic setting parameters ([Pr. PA_ _ ])
- 92 5.1.2 Gain/filter setting parameters ([Pr. PB_ _ ])
- 93 5.1.3 Extension setting parameters ([Pr. PC_ _ ])
- 94 5.1.4 I/O setting parameters ([Pr. PD_ _ ])
- 95 5.1.5 Extension setting 2 parameters ([Pr. PE_ _ ])
- 96 5.1.6 Extension setting 3 parameters ([Pr. PF_ _ ])
- 97 5.1.7 Option setting parameters ([Pr. Po_ _)
- 99 5.2 Detailed list of parameters
- 99 5.2.1 Basic setting parameters ([Pr. PA_ _ ])
- 106 5.2.2 Gain/filter setting parameters ([Pr. PB_ _ ])
- 115 5.2.3 Extension setting parameters ([Pr. PC_ _ ])
- 120 5.2.4 I/O setting parameters ([Pr. PD_ _ ])
- 122 5.2.5 Extension setting 2 parameters ([Pr. PE_ _ ])
- 123 5.2.6 Extension setting 3 parameters ([Pr. PF_ _ ])
- 125 5.2.7 Option setting parameters ([Pr. Po_ _)
- 126 6. TROUBLESHOOTING
- 126 6.1 Alarm and warning list
- 131 6.2 Troubleshooting at power on
- 134 7. DIMENSIONS
- 135 7.1 Servo amplifier
- 135 7.1.1 200 V class
- 144 7.1.2 400 V class
- 151 7.2 MR-J3-T10 CC-Link IE Field Network interface unit
- 152 8. OPTIONS AND PERIPHERAL EQUIPMENT
- 153 8.1 Combinations of cable/connector sets
- 155 8.2 Cable for CC-Link IE Field Network
- 156 APPENDIX
- 156 App. 1 Peripheral equipment manufacturer (for reference)
- 156 App. 2 Analog monitor
- 159 App. 3 Special specification
- 161 REVISIONS
- 162 Country/Region
- 163 Warranty