Instruction Manual for SUPERLINE series battery back-ups
INTRODUCTION
Thank you for purchasing the EVER SUPERLINE battery back-up (UPS). It is the latest series of state-of-the-art power supply devices designed to work with servers, computer networks, and data processing systems.
The SUPERLINE series EVER UPS was designed so as to meet all your expectations for protection against power loss.
This instruction manual contains information pertaining to the control of the device, as well as rules for safe operation. Please familiarise yourself with the contents of this manual prior to beginning your work with the EVER SUPERLINE battery back-up in order to ensure proper usage. The battery back-up was manufactured in Poland and its structure conforms to requirements of the CE symbol.
GENERAL INFORMATION
PURPOSE OF THE DEVICE
SUPERLINE series battery back-ups are ONLINE (VFI)-class devices designed for work with equipment powered by monophase ~230 mains.
WARNING! SUPERLINE battery back-ups were not designed to
work with life and/or health support medical equipment.
GENERAL FEATURES
SUPERLINE battery back-ups consist of the following functional units:
•
•
•
•
•
•
•
Rectifier assembly with PFC system (power factor correction),
Accumulator charger,
Accumulator assembly,
Inverter utilising the high-frequency IGBT technology,
Automatic bypass system (static BYPASS),
Manual (maintenance) bypass system (manual UPS/BYPASS switch),
Microchip control system with measuring systems.
2010/01/13 www.ever.eu
3
Instruction Manual for SUPERLINE series battery back-ups
Figure 1: Simplified block diagram of the battery back-up
The input rectifier converts the alternating mains current to a direct current. The power factor correction system used in the rectifier enables significant elimination of noise transferred to the power system. The direct current bus is the main source of power of the inverter which produces sine alternating current that powers the receivers. An internal charger is responsible for charging the accumulator; it has a very low alternating charging current component, which significantly extends accumulator life. The microchip control system ensures precise and reliable operating of the whole power supply system.
The automatic bypass system increases the safety of the whole system. If the tolerance limits for the parameters of the inverter are exceeded, the mains current is provided to the load directly. This way the automatic bypass system constitutes an additional, passive safeguard of connected load. The additional function of manual engaging of the bypass enables complete powering of load from the mains. This way it is possible to supply power to the load from the mains without any involvement of the battery back-up’s internal functional units.
2010/01/13 www.ever.eu
4
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 2 TABLE OF CONTENTS
- 3 INTRODUCTION
- 3 GENERAL INFORMATION
- 3 PURPOSE OF THE DEVICE
- 3 GENERAL FEATURES
- 5 ELEMENTS OF THE BATTERY BACK-UP
- 6 USER INTERFACE
- 8 SCREENS
- 8 Main menu
- 9 The POMIARY (MEASUREMENTS) submenu
- 11 The KONTROLA (CONTROL) submenu
- 13 The KONFIGURACJA (CONFIGURATION) submenu
- 15 The ALARMY (ALERTS) submenu
- 17 The STATYSTYKA (STATISTICS) submenu
- 18 The USTAWIENIA PANELU (PANEL SETTINGS) submenu
- 19 The IDENTYFIKACJA (IDENTIFICATION) submenu
- 20 SAFETY AND HEALTH INSTRUCTIONS
- 20 HANDLING
- 20 ELECTRIC SAFETY
- 21 INSTALLATION
- 21 UNPACKING
- 22 INSTALLATION OF THE BATTERY BACK-UP
- 23 THE BATTERY MODULE
- 23 Connecting the modules
- 24 Disconnecting the modules
- 25 CONNECTING THE BATTERY BACK-UP
- 25 Connection terminals
- 26 Electric system
- 27 STARTING THE BATTERY BACK-UP
- 27 POWERING OFF AND DISCONNECTING THE BATTERY BACK-UP
- 28 OPERATING MODES OF THE BATTERY BACK-UP
- 30 OTHER FUNCTIONAL ELEMENTS
- 30 Safeguards
- 32 Manual BYPASS
- 33 COMMUNICATION BETWEEN THE UPS AND A COMPUTER
- 33 COMMUNICATION VIA RS232 OR USB
- 33 EVER SNMP/HTTP NETWORK CONTROL CARD
- 35 INSTALLATION AND CONFIGURATION OF THE POWERSOFT PERSONAL SOFTWARE
- 35 Installation on computers with Windows
- 35 Installation on computers with Linux/Unix
- 36 Software updates
- 37 ADDITIONAL REMARKS
- 38 BATTERY BACK-UP AND POWER GENERATORS
- 38 STORAGE, MAINTENANCE AND TRANSPORT
- 38 DISPOSAL
- 39 TECHNICAL PARAMETERS
- 39 INSTALLATION GUIDELINES
- 40 TECHNICAL DATA
- 41 INFORMATION REGARDING REGULATIONS AND WARRANTY
- 41 DECLARATION OF CONFORMITY
- 41 WARRANTY