Clean the unit. Isgus PERFECT 2005, PERFECT 2010
Διαφήμιση
Διαφήμιση
Proceeding
1.
2.
3.
4.
Unit is switched on.
Press "R" and "E" simultaneously and keep these keys pressed for 1 second.
→ Column pointer moves to the park position right of the funnel shield.
Press the locking straps on the left and right side of the card funnel slightly towards the recorder and swing out the programming panel.
Pull off ribbon cassette upwards.
Warning!
According to the print duration, the printer head may be very hot.
Touching the printer head could cause burns.
5.
6.
7.
8.
Insert new ribbon cassette and push slightly down.
Tighten the new ribbon by winding the red ribbon tightening knob in the direction indicated by the arrow on the cassette. Position the free guide of the ribbon in the direction of the printer head.
Make sure that the ribbon guide is inserted in front of the printer head and that the ribbon is not twisted or creased.
The ribbon cassette must engage into the left and right locking straps.
Check that the ribbon fits between the printer head and the ribbon guide.
Tighten the ribbon once again.
Swing in the programming panel.
Press "R" and "E" once again, see section 2.
→ The column pointer moves back to initial position.
Close the unit.
Clean the unit
Note the following recommendations when cleaning the unit. Any cleaning beyond these recommendations must only be carried out by a service technician.
•
•
•
•
Use only rags moistened with water or a soap-free detergent.
Do not use any detergent spray or wet rags.
Use only soft detergents, but never any detergent with solvent.
Make sure that all components are dry after being cleaned.