Mirrorball Motor DMX 2 channel

Fixture Linking

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run synchronized shows of two or more fixtures set to a master/slave operating mode. The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support.

Important: Fixtures on a serial data link must be daisy-chained in a single line. To comply with the

EIA-485 standard, no more than 30 devices should be connected on one data link.

Connecting more than 30 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal.

Maximum recommended DMX data link distance: 100 meters

Maximum recommended number of fixtures on a DMX data link: 30 fixtures

Data Cabling

To link fixtures together, you must obtain data cables. You can purchase DAP Audio certified DMX cables directly from a dealer/distributor or construct your own cable. If you choose to create your own cable, please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic interference.

DAP Audio DMX Data Cables

• DAP Audio Basic microphone cable for allround use. bal. XLR/M 3-pin > XLR/F 3-pin.

Ordercode FL01150 (1,5 m), FL013 (3 m), FL016 (6 m), FL0110 (10 m), FL0115 (15 m), FL0120 (20 m).

• DAP Audio X-type data cable XLR/M 3-pin > XLR/F 3-pin. Ordercode FLX0175 (0,75 m),

FLX01150 (1,5 m), FLX013 (3 m), FLX016 (6 m), FLX0110 (10 m).

• DAP Audio cable for the demanding user with exceptional audio-qualities and connector made by

Neutrik®. Ordercode FL71150 (1,5 m), FL713 (3 m), FL716 (6 m), FL7110 (10 m).

• DAP Audio cable for the demanding user with exceptional audio-qualities and connector made by

Neutrik®. Ordercode FL7275 (0,75 m), FL72150 (1,5 m), FL723 (3 m), FL726 (6 m), FL7210 (10 m).

• DAP Audio 110 Ohm cable with digital signal transmission. Ordercode FL0975 (0,75 m),

FL09150 (1,5 m), FL093 (3 m), FL096 (6 m), FL0910 (10 m), FL0915 (15 m), FL0920 (20 m).

DMX Channels

2 Channels

Channel 1 – Lamp ON/OFF

0-127

128-255

Lamp OFF

Lamp ON

Channel 2 – Motor rotation

0

1-127

Not functional

Clockwise rotation, from fast to slow

128

129-255

Stop

Counterclockwise rotation, from slow to fast