ADJUSTMENT SECTION
19
PROGRAM THE TRAVEL LIMITS AND FORCE SETTINGS
figure 1 which activates a mechanical passpoint during the door travel.
The indicator LED will blink when this occurs. If the passpoint
Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or
KILLED by a closing door.
• Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system.
• NEVER use force adjustments to compensate for a binding or sticking garage door.
• After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 40 mm high object laid flat
on floor.
TO PROGRAM THE TRAVEL LIMITS:
1. Press the PROG Button until the UP Arrow Button and indicator
LED begin to flash (figure 2).
desired UP position (figure 3).
“The Protector System TM ” must be used for all installations where the closing force as measured on the bottom of the door is over
400 N (40 kgf).
Installers should ensure that the doors are installed in a compliant manner as per AS/NZS 60335-2-95.
To prevent damage to vehicles, be sure fully open door provides adequate clearance.
4).
4. Press and hold the DOWN Arrow Button until the door is in the desired DOWN position (figure 5).
NOTE: The UP and DOWN Arrow Buttons can be used to move the door up and down as needed.
5. Once the door is in the desired DOWN position press and release figure 2
Indicator LED
SETTING THE FORCE (AUTO):
6. Press and release the UP Arrow Button to test the UP limit. When
Arrow Button will begin to flash.
7. Press and release the DOWN Arrow Button to test the DOWN limit. The door will travel to the programmed DOWN limit.
setting has now been set. Proceed to test safety reverse system.
SETTING THE FORCE (MANUAL LEARN IF REQUIRED):
1. Open the rear access panel. Locate the yellow Learn button.
adjustment mode. The LED (indicator light) will flash quickly.
3. Push the programmed remote control or push the UP/DOWN figure 3 figure 4
Indicator LED
Indicator LED will travel to the UP (open) position.
limit. The door will travel to the programmed DOWN limit.
The LED (indicator light) will stop flashing when the force has been set. The door must travel through a complete cycle, UP and DOWN, in order for the force to be set properly. If the unit cannot open and close your door fully, inspect your door to insure that it is not sticking or binding.
The Force Setting has now been set manually.
11 figure 5
Indicator LED
g.
n e
20
TEST THE SAFETY REVERSE SYSTEM
The safety reverse system test is important. Garage door must reverse on contact with a 40 mm obstacle laid flat on the floor. Failure to properly adjust opener may result in serious personal injury from a closing garage door. Repeat test once a month and adjust as needed.
Procedure: With door opened place a 40 mm obstacle (1) laid flat on the floor under the garage door. Operate the door in the down direction. The door must reverse off the obstacle. If the door stops on the obstacle, remove obstacle and repeat Program the Limits and Force Steps, then repeat safety reverse test.
When the door reverses off the 40 mm obstacle, remove the obstacle and run the opener through a complete travel cycle. Door must not reverse in closed position. If it does, repeat Program the Limits and Force then repeat safety reverse test.
40 mm high 1
21
PROGRAM THE TRAVEL SPEED
DOOR SPEED SELECTION:
The “CyclonePro” opener has been designed to work with a wide range of garage doors with a total mass up to 286kg.
The CyclonePro can be set on NORMAL speed when operating doors with a total mass of less than 130Kg.
“The Protector System TM ” must be used for all installations where the closing force as measured on the bottom of the door is over 400 N (40 kgf).
When the CyclonePro is installed on doors with a total mass exceeding 130kg the operator should be set on SLOW speed mode. The “Protector System” must be installed when SLOW speed mode is selected.
Installers should ensure that the doors are installed in a compliant manner as per AS/NZS 60335-2-95.
TRAVEL SPEED:
There are two travel speeds available for this opener.
Factory default is set to the NORMAL speed.
TRAVEL SPEED: Manually selected:
The speed can be set manually if required, using the following method.
To activate the alternate speed:
PRESS and HOLD both the UP and DOWN arrows for 3 seconds.The courtesy lamp will flash once to confirm SLOW speed and twice to confirm NORMAL speed.
To deactivate the selected speed: Repeat the process above (toggle between the two settings).
22
PROGRAM THE LOW STANDBY MODE (OPTIONAL)
Low Standby Mode (sub 1 watt) is activated by the factory to deliver the lowest possible standby power.
In this mode the External Accessories Power and the IR Beams are turned OFF when the door is closed and the courtesy light is OFF. IR Beams operate normally in Low Standby mode.
At mains turn ON: Courtesy light flashes 2 times = Low Standby Mode
Courtesy light flashes 10 times = Normal Standby Mode
The Normal Standby Mode will need to be activated for External Accessories Power.
To Activate Normal Standby Mode:
Turn the mains power OFF.
PRESS and HOLD both the UP and DOWN arrows simultaneously.
Turn ON mains power while both the arrow buttons are still pressed.
Courtesy light comes on and after 5 seconds another 10 flashes.
Release the arrow buttons.
Indicator LED
To Activate Low Standby Mode:
Turn the mains power OFF.
PRESS and HOLD both the UP and DOWN arrows simultaneously.
Turn ON mains power while both the arrow buttons are still pressed.
Courtesy light comes on and after 5 seconds another 1 flash.
Release the arrow buttons.
12