INSTALL THE PROTECTOR SYSTEM
TM
(see section 21 if required)
NOTE: This accessory must be used for all installations where the closing force as measured on the bottom of the door is over 400 N (40 kgf).
S openers.
TM be installed on all garage door
IR BEAMS: By installing IR Beams, an open door is prevented from closing if a person or object is located in the beam area. If the door is already closing, it will return to the open position. A closed door is not prevented from opening.
If the Protector System TM is installed and needs to be removed, the opener will need to be reprogrammed (refer to paragraph 4 of the troubleshooting section).
Assembly Process:
The IR Beams are supplied preassembled, complete with two sensors, wiring and wall brackets. (fig1 & fig2)
Install the mounting brackets and sensors to either side of the inside of the garage door, and at a height of no greater than
100 mm off the garage floor.
The brackets are designed to be used for Wall or Floor fixing, with a variety of hole combinations to achieve the desired results.
Drill the required holes and install the brackets with wall plugs and screws provided. Ensure they do not obstruct the door movement.
Wiring Process:
Align the Sensors to face each other and tighten if necessary.
The wiring should exit from the bottom of the housing to maintain the correct IP rating and continued operation.
One sensor is a Sending Eye , the other is a Receiving Eye. Try to avoid positioning these in direct sunlight as this may interfere with the operation of the beams.
Run both sets of wire back to the power head CONTROL
PANEL. Ensure the wire is well supported and does not interfere or get damaged by movement of the door panels or spring hardware.
Remove Power from the Unit:
At the Power head end, cut the wires to the correct length and strip each back around 10 mm.
Twist both White wires together and install into “quick release” terminal 2 (white) (fig 3)
Twist both Black/White wires together and install into “quick release” Terminal 3 (Grey) (fig 3)
(The sensors are a 2 wired system connected in a parallel configuration).
Reinstall Power to the Unit:
When aligned correctly the Red LED on each sensor will remain “ON constantly”.
If incorrectly aligned both LEDs will “flash”.
Correct the alignment if necessary.
The opener is now ready to be checked for correct IR Beam operation.
13 figure 1
7 74 I R
B E A M
T o prevent entrapment, install The Protector
System™ no higher than 100 mm above the floor.
Disconnect power to the garage door opener before installing The Protector System™.
figure 2 figure 3 view 1
30 V DC
+ -
M6 F L
N U T
A N G E
White x 2
0 1 2 2 3 4 5 6 7
INDICATOR
LED
LEARN
(YELLOW)
2 CORE
WIRE CABLE
M6 C O A C H
S C R E W
WALL
BRACKET view 2
Black/White x 2
UP
PROG
DOWN
PLASTIC WALL
PLUG
W A LL
S C R E W
Ladda ner
Annons