Peripherals Command List. D-Link DGS-3000 series
Oglas
Oglas
DGS-3000 Series Layer 2 Managed Gigabit Ethernet Switch CLI Reference Guide
Chapter 63 Peripherals Command List
show device_status show environment
config temperature threshold {high <temperature -500-500> | low <temperature -500-500>}
config temperature [trap | log] state [enable | disable]
63-1 show device_status
Description
This command is used to display current status of fans on the system. An “OK” message is displayed when all of the fans are working properly. A “Fail” message is displayed when any of the fans failed. The failed fan number is included in the fail message.
Format show device_status
Parameters
None.
Restrictions
None.
Example
To show device status:
DGS-3000-26TC:admin#show device_status
Command: show device_status
Right Fan : OK
DGS-3000-26TC:admin#
63-2 show environment
Description
This command is used to display the temperature status of the system.
Format show environment
Parameters
None.
577
DGS-3000 Series Layer 2 Managed Gigabit Ethernet Switch CLI Reference Guide
Restrictions
None.
Example
To display the device environment:
DGS-3000-26TC:admin#show environment
Command: show environment
Temperature Trap State : Enabled
Temperature Log State : Enabled
Current Temperature(Celsius) : 27
High Warning Temperature Threshold(Celsius) : 79
Low Warning Temperature Threshold(Celsius) : 11
DGS-3000-26TC:admin#
63-3 config temperature threshold
Description
This command is used to configure the warning threshold for high and low temperature.
Format config temperature threshold {high <temperature -500-500> | low <temperature -500-500>}
Parameters
high - (Optional) Specify to configure high threshold value. The high threshold must bigger than the low threshold.
<temperature -500-500> - Enter the high threshold temperature.
low - (Optional) Specify to configure low threshold value.
<temperature -500-500> - Enter the low threshold temperature.
Restrictions
Only Administrators and Operators can issue this command.
Example
To configure the warning temperature threshold:
DGS-3000-26TC:admin#config temperature threshold high 80
Command: config temperature threshold high 80
Success.
DGS-3000-26TC:admin#
63-4 config temperature
Description
This command is used to configure the trap state for temperature warning event.
578
DGS-3000 Series Layer 2 Managed Gigabit Ethernet Switch CLI Reference Guide
Format config temperature [trap | log] state [enable | disable]
Parameters
trap - Specify to enable or disable the trap state of the temperature warning event.
log - Specify to enable or disable the log state of the temperature warning event.
state - Specify to enable or disable the trap or log state of the temperature warning event.
enable - Specify to enable the trap or log state of the temperature warning event. This is the default option.
disable - Specify to disable the trap or log state of the temperature warning event.
Restrictions
Only Administrators and Operators can issue this command.
Example
To configure the warning temperature trap state:
DGS-3000-26TC:admin#config temperature trap state enable
Command: config temperature trap state enable
Success.
DGS-3000-26TC:admin#